Академический Документы
Профессиональный Документы
Культура Документы
Bored Pile
BH1
1
Pile Size / mm
Structural
Capacity / kN
Geotechnical
Capacity / kN
Allowable
Capacity / kN
Penetration
Length / m
Provided
Capacity / kN
600
1000
1200
1500
1979
5498
7917
12370
973
2091
2790
4015
973
2091
2790
4015
23
23
23
23
900
2000
2700
4000
Ks Adopted =
Kb Adopted =
Maximum End Bearing =
Maximum Skin Friction =
2
2.0
10000
kN/m2
150
kN/m
Designed by:
Date:
Checked by:
Date:
BH 1
1500mm
1.5
35
m
fcu
N/mm2
35
Skin Friction
Ks adopted for all soil
Soil Type
Depth
from
Depth
to
1.2
2.7
4.3
20.6
21.8
2.7
4.3
20.6
21.8
23
(NOTE: value of coefficient Ks is between 1.5 to 2.5; however, common value Ks adopted is 2)
Unit skin
NOld
Shaft
Shaft Friction
value Alluvium? length (m) friction (kN/m2)
(kN)
5
2
11
17
100
n
n
n
n
n
Total
1.2
1.5
1.6
16.3
1.2
1.2
0
10
4
22
34
150
0
0
23
Ultimate Pile Shaft Capacity, Qs (kN) =
70.7
30.2
1689.9
192.3
848.2
0.0
0.0
2831.2
2831.2
KN, or
288.6
Tonne
(NOTE: max unit skin friction of bored pile in contact with soil, is limited to 150KN/m 2)
(NOTE: max unit skin friction of bored pile in contact with Old Alluvium, an OC cemented sand, is limited to 300KN/m 2)
Base Resistance
a) Find Average N-Value
Compute average N values 6 diameters above pile toe and 4 diameters below pile toe required to develop base reasistance.
Required length of 6 diameters above pile toe =
9
m
Depth of 3rd layer soil above pile toe =
Depth of 2nd last layer soil above pile toe =
Depth of last layer soil above pile toe =
6.6
1.2
1.2
m,
m,
m,
11
17
100
6
0.0
6.0
m
m,
m,
0
100
54.2
23.0 m
not used
54
2.0
2.0
1.5
5
1.6
25.0
KN/m2
70.7
KN
4,336.0 KN/m2
1.7671 m2
112.2
182.9
KN
KN, or
18.6
Tonne
7,662.3
2,831.2
KN, or
KN, or
781.1
288.6
Tonne
Tonne
4,014.6
23.0
KN, or
m
409.2
Tonne
7.0
12,370.0
1.0
17,671.5
N/mm2
KN, or
1,261.0
Tonne
Factor of Safety
Skin Friction
End Bearing
Allowable Capacity (kN)
Case 1
1.5
3
4,258.7
Case 2
2.5
2.5
4,014.6 KN
mm2
Preferably, the geotechnical capacity is more than the structural capacity - No - geotechnical capacity is less
Design Pile Capacity Adopted, Qa (ton)=
409.2
Tonne
Designed by:
Date:
Checked by:
Date:
BH 1
1200mm
1.2
35
m
fcu
N/mm2
35
Skin Friction
Ks adopted for all soil
Soil Type
Depth
from
Depth
to
1.2
2.7
4.3
20.6
21.8
2.7
4.3
20.6
21.8
23
(NOTE: value of coefficient Ks is between 1.5 to 2.5; however, common value Ks adopted is 2)
Unit skin
NOld
Shaft
Shaft Friction
value Alluvium? length (m) friction (kN/m2)
(kN)
5
2
11
17
100
n
n
n
n
n
Total
1.2
1.5
1.6
16.3
1.2
1.2
0
10
4
22
34
150
0
0
23
Ultimate Pile Shaft Capacity, Qs (kN) =
56.5
24.1
1351.9
153.8
678.6
0.0
0.0
2265.0
2265.0
KN, or
230.9
Tonne
(NOTE: max unit skin friction of bored pile in contact with soil, is limited to 150KN/m 2)
(NOTE: max unit skin friction of bored pile in contact with Old Alluvium, an OC cemented sand, is limited to 300KN/m 2)
Base Resistance
a) Find Average N-Value
Compute average N values 6 diameters above pile toe and 4 diameters below pile toe required to develop base reasistance.
Required length of 6 diameters above pile toe =
7.2
m
Depth of 3rd layer soil above pile toe =
Depth of 2nd last layer soil above pile toe =
Depth of last layer soil above pile toe =
4.8
1.2
1.2
m,
m,
m,
11
17
100
4.8
0.0
4.8
m
m,
m,
0
100
56.1
23.0 m
not used
56
2.0
2.0
1.5
5
1.6
25.0
KN/m2
56.6
KN
4,488.0 KN/m2
1.1310 m2
89.7
146.3
KN
KN, or
14.9
Tonne
5,075.8
2,265.0
KN, or
KN, or
517.4
230.9
Tonne
Tonne
2,790.0
23.0
KN, or
m
284.4
Tonne
7.0
7,916.8
1.0
11,309.7
N/mm2
KN, or
807.0
Tonne
Factor of Safety
Skin Friction
End Bearing
Allowable Capacity (kN)
Case 1
1.5
3
3,055.6
Case 2
2.5
2.5
2,790.0 KN
mm2
Preferably, the geotechnical capacity is more than the structural capacity - No - geotechnical capacity is less
Design Pile Capacity Adopted, Qa (ton)=
284.4
Tonne
Designed by:
Date:
Checked by:
Date:
BH 1
1000mm
1
35
m
fcu
N/mm2
35
Skin Friction
Ks adopted for all soil
Soil Type
Depth
from
Depth
to
1.2
2.7
4.3
20.6
21.8
2.7
4.3
20.6
21.8
23
(NOTE: value of coefficient Ks is between 1.5 to 2.5; however, common value Ks adopted is 2)
Unit skin
NOld
Shaft
Shaft Friction
value Alluvium? length (m) friction (kN/m2)
(kN)
5
2
11
17
100
n
n
n
n
n
Total
1.2
1.5
1.6
16.3
1.2
1.2
0
10
4
22
34
150
0
0
23
Ultimate Pile Shaft Capacity, Qs (kN) =
47.1
20.1
1126.6
128.2
565.5
0.0
0.0
1887.5
1887.5
KN, or
192.4
Tonne
(NOTE: max unit skin friction of bored pile in contact with soil, is limited to 150KN/m 2)
(NOTE: max unit skin friction of bored pile in contact with Old Alluvium, an OC cemented sand, is limited to 300KN/m 2)
Base Resistance
a) Find Average N-Value
Compute average N values 6 diameters above pile toe and 4 diameters below pile toe required to develop base reasistance.
Required length of 6 diameters above pile toe =
6
m
Depth of 3rd layer soil above pile toe =
Depth of 2nd last layer soil above pile toe =
Depth of last layer soil above pile toe =
3.6
1.2
1.2
m,
m,
m,
11
17
100
4
0.0
4.0
m
m,
m,
0
100
58
23.0 m
not used
58
2.0
2.0
1.5
5
1.6
25.0
KN/m2
47.1
KN
4,640.0 KN/m2
0.7854 m2
74.8
121.9
KN
KN, or
12.4
Tonne
3,644.2
1,887.5
KN, or
KN, or
371.5
192.4
Tonne
Tonne
2,090.8
23.0
KN, or
m
213.1
Tonne
7.0
5,497.8
1.0
7,854.0
N/mm2
KN, or
560.4
Tonne
Factor of Safety
Skin Friction
End Bearing
Allowable Capacity (kN)
Case 1
1.5
3
2,351.2
Case 2
2.5
2.5
2,090.8 KN
mm2
Preferably, the geotechnical capacity is more than the structural capacity - No - geotechnical capacity is less
Design Pile Capacity Adopted, Qa (ton)=
213.1
Tonne
Designed by:
Date:
Checked by:
Date:
BH 1
0.8
35
m
fcu
N/mm2
35
Skin Friction
Ks adopted for all soil
Soil Type
Depth
from
Depth
to
1.2
2.7
4.3
20.6
21.8
2.7
4.3
20.6
21.8
23
(NOTE: value of coefficient Ks is between 1.5 to 2.5; however, common value Ks adopted is 2)
Unit skin
NOld
Shaft
Shaft Friction
value Alluvium? length (m) friction (kN/m2)
(kN)
5
2
11
17
100
n
n
n
n
n
Total
1.2
1.5
1.6
16.3
1.2
1.2
0
10
4
22
34
150
0
0
23
Ultimate Pile Shaft Capacity, Qs (kN) =
37.7
16.1
901.3
102.5
452.4
0.0
0.0
1510.0
1510.0
KN, or
153.9
Tonne
(NOTE: max unit skin friction of bored pile in contact with soil, is limited to 150KN/m 2)
(NOTE: max unit skin friction of bored pile in contact with Old Alluvium, an OC cemented sand, is limited to 300KN/m 2)
Base Resistance
a) Find Average N-Value
Compute average N values 6 diameters above pile toe and 4 diameters below pile toe required to develop base reasistance.
Required length of 6 diameters above pile toe =
4.8
m
Depth of 3rd layer soil above pile toe =
Depth of 2nd last layer soil above pile toe =
Depth of last layer soil above pile toe =
2.4
1.2
1.2
m,
m,
m,
11
17
100
3.2
0.0
3.2
m
m,
m,
0
100
60.85
23.0 m
not used
61
2.0
2.0
1.5
5
1.6
25.0
KN/m2
37.7
KN
4,868.0 KN/m2
0.5027 m2
59.8
97.5
KN
KN, or
9.9
Tonne
2,446.9
1,510.0
KN, or
KN, or
249.4
153.9
Tonne
Tonne
1,485.2
23.0
KN, or
m
151.4
Tonne
7.0
3,518.6
1.0
5,026.5
N/mm2
KN, or
358.7
Tonne
Factor of Safety
Skin Friction
End Bearing
Allowable Capacity (kN)
Case 1
1.5
3
1,724.8
Case 2
2.5
2.5
1,485.2 KN
mm2
Preferably, the geotechnical capacity is more than the structural capacity - No - geotechnical capacity is less
Design Pile Capacity Adopted, Qa (ton)=
151.4
Tonne
Designed by:
Date:
Checked by:
Date:
BH 1
600mm
0.6
35
m
fcu
N/mm2
35
Skin Friction
Ks adopted for all soil
Soil Type
Depth
from
Depth
to
1.2
2.7
4.3
20.6
21.8
2.7
4.3
20.6
21.8
23
(NOTE: value of coefficient Ks is between 1.5 to 2.5; however, common value Ks adopted is 2)
Unit skin
NOld
Shaft
Shaft Friction
value Alluvium? length (m) friction (kN/m2)
(kN)
5
2
11
17
100
n
n
n
n
n
Total
1.2
1.5
1.6
16.3
1.2
1.2
0
10
4
22
34
150
0
0
23
Ultimate Pile Shaft Capacity, Qs (kN) =
28.3
12.1
675.9
76.9
339.3
0.0
0.0
1132.5
1132.5
KN, or
115.4
Tonne
(NOTE: max unit skin friction of bored pile in contact with soil, is limited to 150KN/m 2)
(NOTE: max unit skin friction of bored pile in contact with Old Alluvium, an OC cemented sand, is limited to 300KN/m 2)
Base Resistance
a) Find Average N-Value
Compute average N values 6 diameters above pile toe and 4 diameters below pile toe required to develop base reasistance.
Required length of 6 diameters above pile toe =
3.6
m
Depth of 3rd layer soil above pile toe =
Depth of 2nd last layer soil above pile toe =
Depth of last layer soil above pile toe =
1.2
1.2
1.2
m,
m,
m,
11
17
100
2.4
0.0
2.4
m
m,
m,
0
100
65.6
23.0 m
not used
66
2.0
2.0
1.5
5
1.6
25.0
KN/m2
28.3
KN
5,248.0 KN/m2
0.2827 m2
44.9
73.1
KN
KN, or
7.5
Tonne
1,483.8
1,132.5
KN, or
KN, or
151.3
115.4
Tonne
Tonne
973.4
23.0
KN, or
m
99.2
Tonne
7.0
1,979.2
1.0
2,827.4
N/mm2
KN, or
201.8
Tonne
Case 1
1.5
3
1,176.5
Case 2
2.5
2.5
973.4 KN
mm2
Preferably, the geotechnical capacity is more than the structural capacity - No - geotechnical capacity is less
Design Pile Capacity Adopted, Qa (ton)=
99.2
Tonne
Designed by:
Date:
Checked by:
Date:
0.3
40
m
fcu
40
N/mm2
Skin Friction
Ks adopted for all soil
Soil Type
Depth
from
Depth
to
1.2
5
10.8
14.8
5
10.8
14.8
26.2
(NOTE: value of coefficient Ks is between 1.5 to 2.5; however, common value Ks adopted is 2)
Unit skin
NOld
Shaft
Shaft Friction
value Alluvium? length (m) friction (kN/m2)
(kN)
8
6
10
22
n
n
n
n
n
Total
3.8
5.8
4
11.4
0
16
12
20
44
0
0
0
25
Ultimate Pile Shaft Capacity, Qs (kN) =
57.3
65.6
75.4
472.7
0.0
0.0
0.0
671.0
671.0
KN, or
68.4
Tonne
(NOTE: max unit skin friction of bored pile in contact with soil, is limited to 150KN/m 2)
(NOTE: max unit skin friction of bored pile in contact with Old Alluvium, an OC cemented sand, is limited to 300KN/m 2)
Base Resistance
a) Find Average N-Value
Compute average N values 6 diameters above pile toe and 4 diameters below pile toe required to develop base reasistance.
Required length of 6 diameters above pile toe =
1.8
m
Depth of 3rd layer soil above pile toe =
Depth of 2nd last layer soil above pile toe =
Depth of last layer soil above pile toe =
0.0
0.0
1.8
m,
m,
m,
0
0
22
1.2
0.0
1.2
m
m,
m,
0
100
53.2
25.0 m
not used
53
1.0
1.0
3.0
5
8.0
20.0
KN/m
28.3
KN
2,128.0 KN/m2
0.0707 m2
89.7
118.0
KN
KN, or
12.0
Tonne
150.4
821.5
KN, or
KN, or
15.3
83.7
Tonne
Tonne
210.6
25.0
KN, or
m
21.5
Tonne
7.5
530.1
1.0
706.9
N/mm2
KN, or
54.0
Tonne
m
2
Factor of Safety
Skin Friction
End Bearing
Allowable Capacity (kN)
Case 1
1.5
3
379.5
Case 2
2.5
2.5
210.6 KN
mm2
Preferably, the geotechnical capacity is more than the structural capacity - No - geotechnical capacity is less
Design Pile Capacity Adopted, Qa (ton)=
21.5
Tonne
Designed by:
Date:
Checked by:
Date:
Size of RC Pile
Concrete Grade
0.35
45
m
fcu
45
N/mm2
Skin Friction
Ks adopted for all soil
Soil Type
Clayey Silt
Sandy Silt
Sandy Silt
Silty sand
Very dense silty sand
Depth
from
Depth
to
8.5
9.6
11.8
19.5
31.5
9.6
11.8
19.5
31.5
32.5
14
27
45
0
0
n
n
n
n
n
Total
1.1
2.2
7.7
12
1
42
81
135
0
0
0
0
24
Ultimate Pile Shaft Capacity, Qs (kN) =
64.7
249.5
1455.3
0.0
0.0
0.0
0.0
1769.5
1769.5
KN, or
180.4
Tonne
(NOTE: max unit skin friction of bored pile in contact with soil, is limited to 200KN/m 2)
(NOTE: max unit skin friction of bored pile in contact with Old Alluvium, an OC cemented sand, is limited to 300KN/m 2)
(NOTE: Unless predrilling is adopted, RC pile shall at most be founded on SPT 50 - 70 material or on rock in the layer of SPT 50 - 70 material is adsent)
Base Resistance
a) Find Average N-Value
Compute average N values 6 diameters above pile toe and 4 diameters below pile toe required to develop base reasistance.
Required length of 6 diameters above pile toe =
2.1
m
Depth of 3rd layer soil above pile toe =
Depth of 2nd last layer soil above pile toe =
Depth of last layer soil above pile toe =
0.0
0.0
2.1
m,
m,
m,
0
0
65
1.4
0.0
1.4
m
m,
m,
0
100
79
24.0 m
not used
79
6.0
6.0
KN/m2
0.0
KN
10,000.0 KN/m2
0.1225 m2
0.0
0.0
KN
KN, or
0.0
Tonne
1,225.0
2,994.5
KN, or
KN, or
124.9
305.2
Tonne
Tonne
1,197.8
24.0
KN, or
m
122.1
Tonne
11.25
1,378.1
1.0
1,225.0
N/mm2
KN, or
140.5
Tonne
Case 1 Case 2
1.5
2.5
3
2.5
1,588.0 1,197.8 KN
mm2
122.1
Tonne
Change Log
Design - pile - ver 1.0, date 30 Nov 2001
1. Pile design spreadsheet created.
Design - pile - ver 1.1, date 19 Dec 2001
1. Structural capacity of RC pile amended to 0.25fcu. Structural capacity of bored pile remains at 0.2fcu.
2. Chang log is added.
Design - pile - ver 1.11, date 19 Dec 2001
1. Remedy file size of spreadsheet.
Design - pile - ver 1.12, date 24 Jun 2003
1. The limiting value of rnd bearing for piles is revised to 9,000 KN/m 2 instead of 11,000 KN/m2.
Design - pile - ver 2, date 15 Jul 2003
1. Incorporate key recommendations of CP4 : 2003 for bored pile design & precast RC pile design
Design - pile - ver 2.1, date 16 Jul 2003
1. Incorporate key recommendations of CP4 : 2003 on NSF that is applicable in most cases, by 2 factors 0.85, 0.7 to NSF in so
2. In case of special case of low capacity pile in highly compressible clay stratum, it will be prudent to set both these 2 factors a
ains at 0.2fcu.