S2E STEAM MICROTURBINE

Technological Advantages
and

Technical specification

S2E Module
Technological Advantages
main features

NON-BLADE

CONSTRUCTION

UNUSUALLY HIGH EFFICIENCY

WORKS ALSO WITH WET STEAM

CAPACITY 50-600 KWE


FULL POWER REACTION TIME IN 10 MIN
OPERATING AT UNSTABLE STEAM

CONDITIONS
HEAVY DUTY CONSTRUCTION
PROJECT ORIENTED TECHNICAL DESIGN

S2E 110 Karvina, Czech Republic

NO Blades BUT Bristles


Bristles provide the S2E units and its
operator new perspectives with excellent
technical parameters:
can also operate on the contrary to
classic blade turbines in wet steam
mode
can be operated also during frequent
and quick changes of operational
parameters
regulation is possible from zero to
maximum at unchanged efficiency
rate
operates at low operational
revolutions / 3000 rev/min /
rise time from the cold status to
maximum is up to 10 min.

Comparison btw Bristle and Blade


technology
Range of electric performance
Configuration
General efficiency

Toco GreenTech S2E Microturbine


50-650 kW
S2E Microturbines are delivered within 3-6 Months with complete periphery ( generator,
synchronisator, etc) plug and play

Regular Blade Turbines


> 2000 kW
Large construction projects usually accomplished within 1218 Months

55-60 %

< 50 %

Steam quality

Wide spectrum of in- and outbound steam pressure parameters in particular in the wet steam
area below the saturation curve.
Fast reaction times to fluctuating unstabile steam parameters. Flexible towards constantly
changing inbound pressure parameters. Down to 85% a setback of inbound steam quantity electric
output is linear.
The non-blade bristle turbine operates with dirty steam containing flying particles, fibers. Steam
containing bases and acids -no problem.

Start-up
Philosophy

Usually operates only with superheated dry steam since the


Operates with 85% dry steam ( 15% water content)-pressure will be reduced with special feed-in
flying condens water particles will destroy the turbine
nozzles and bristles and the cinetic energy exposed to the axis will be transmitted with a "noblades due to the cavity. In regular turbines the blades are
gearbox" solution to the generator.
responsible for the pressure drop.
Within 10 minutes from 0 to full load .
Requires 30-60 minutes to warm up.
Process optimalisation and electricity production.
Electricity production.

Steam parameters

Limited spectrum of in- and outbound steam parameters


Reagular steam turbines are not capable of adopting
constantly changing unstabile pressure and quantity
parameters of steam.
Operates only with clean dry steam.

Non Blades Bristles


Technology

Patented design is based on the substitution of turbine blades with system of bristles.
Material of bristles, their cross-section, shape and density are precisely defined .
Multiple tangential input of working medium on the turbine bristles is optimized by the system of nozzles
that enable optimal conversion of kinetic energy of working medium to the force with efficiency of 95%.
Kinetic energy of the working medium is absorbed in the inlet- into the turbine circuit so that for
example, at outlet velocity of 800m/sec of the steam from the nozzles, its energy is completely absorbed
at 80mm of the length of perimeter of the turbine wheel.
Outlet of the working medium is on Archimedean spiral from the center of the turbine.
Condensate removal is solved by separate sub-circuit in the bottom of the turbine.

S2E Bristle Turbine wheel I.

S2E Bristle Turbine wheel customized design

S2E Bristle Turbine wheel after 36 months of operation

At least 48% overall efficiency


of S2E turbines guaranteed
This ( overall) efficiency includes ALL the losses of the equipment from the point of
view of thermal, electrical and mechanical parts. It is the real total efficiency of the
module.
When the turbine operates at the level of designed flow of media from the jet the
module efficiency may exceed 55%
Generator efficiency: 93-95%
Mechanical efficiency: 94%
Efficient alteration of velocity head: 95%
Total Mechanical efficiency: 94%
Total Electrical efficiency: 95%
Total Thermal efficiency: 30-40%

S2E El. Power Output Calculation


Manual Calculation of the turbine capacity

1.point A = intersection of the curved lines :


- incoming steam pressure +1 bar
- incoming steam temperature
2. point B = intersection of the vertical line
from point A with
the curved line of outcoming steam pressure
+1 bar
3. point C = intersection of the horizontal line
from the point A
and the Y-axis = Power P1 / kWe /
4. point D = intersection of the horizontal line
from the point B
and the Y - axis =Power P2 / kWe /
5. TURBINE Power=(P2-P1) x Steam flow
volume(kg/second) kWe

11

S2E Bristle Turbine vs. Blade Turbine


- Dependance on the Steam Flow
p1= 1,4 Mpa, p2=0,2MPa, T1=200 C

S2E Turbine
Rated P for Q=1,06 kg/s
Blade Turbine

This surface equals your


net profit compared to a
classic turbine solution
Q (kg/s)

12

S2E 110 - Input Steam Parameters p1 , T1


p1 (Mpa)

T (hour)

T1 (C)

T (hour)
13

S2E110 Steam flow

Q (t/hour)

T (hour)

14

S2E 110 - Output Steam Pressure vs. El Power Output !!!


p2 (Mpa)

T (hour)
kWe

T (hour)
15

S2E 110 - Output Steam Temperature


T2 (C)

T (hour)

16

By pass the current pressure


reducer

Potential Implementation Scenario of a S2E unit

S2E Module

Range of Steam Parameters


INPUT STEAM PRESSURE
Min 4 bar Absolute
Max 35 bar Absolute
INPUT STEAM TEMPERATURE
Min 130 C
Max 350 C
OUTPUT STEAM PRESSURE
Min 1,1 bar Absolute
Max 6-8 bar Absolute
OUTPUT STEAM TEMPERATURE
Min 105 C
Max 350 C

TECHNOPA GmbH

Hietzinger Hauptstr. 50,


tel.: +43 1 877 0553
www.technopa.eu

STEAM FLOW
Min 1,1 3 t/h
Max 20 t/h
STEAM DRYNESS

Max to 80-85 %

If you have different parameters , please


contact Technopa Technical service or your
local agent

1130 Vienna Austria


fax: +43 1 877 8446
office@technopa.eu

S2E Unit

S2E 200 Solid Turbine Body Construction

21

Sample installations

S2E 50 600 kWe

Complete PLUG and PRODUCE System

S2E Module

... Dimensions

S2E Turbine is designed according to the steam parameters and


operating conditions in order to gain the optimal power output
The size and the power of the turbine define the other
components of module S2E: generators , valves , pipes,
condensation system, cooling system etc.

Turbine sizes
Module S2E 50-250 kWe
Turbine 900 mm diameter
Module S2E 250-500 kWe
Turbine 1200 mm diameter

Modul S2E not containerized


Dimensions without electric and electronic box / only turbine , generator and valve systems /
*Electric and electronics box are separated from the S2E turbine Module

Width /mm/
2000
2500

length /mm/
4800
5200

height
2600
2200

1000

2000

2000

Modul S2E container ized


Dimensions / including electric and electronic box /
Width /mm/

length /mm/

height

Modul S2E 50-250 max diameters :


Modul S2E 250-500 max diameters :

6800
7200

2600
3100

Modul S2E 50-250 max diameters :


Modul S2E 250-500 max diameters :
EXTRA
Electro box
max diameters :

2000
2500

/mm/

max weight
4,9 t
7t

/t/

1t

/mm/

max weight
5,6 t
9,5 t

/t/

Control of the S2E operation


Description:

The whole S2E device is designed as unattended, with the exception of S2E cold state (cold start). The
control system manages automatic operation including start-up of S2E of warm state (warm start), shutdown
and control potential safety and emergency shutdown of S2E and putting into a safe condition.
The control system is furnished with an operating panel (OP) that extends the capabilities of
monitoring, diagnostics and parameterization S2E and control system and increases the comfort for the
operator.
All the control functions are not available without appropriate authorization.
The complete set of the system parameters (provided by the service organization) provide a secure
automatic and manual operation of the S2E units.
All manual switches are controlled by the control system. In the case of any unproper instruction is given
manually by the operator, the control system defends the S2E module by the safe shut down in order to
avoid any demages.
Manual operation is intended primarily for service purposes.

S2E CONTROL AND REGULATION PRINCIPLES


Steam turbine is controlled by programmable logical controller (PLC) SIMATIC produced by Siemens.
Controlling system regulates inlet of steam by elevation of control valve, which is controlled pneumatically
and is capable of emergency close.
This Control system:
controls the control valve in order to keep required (regulated) values
controls connection of generator: to network and disconnection from network by main switch, which is
controlled by motor drive, provides for oil management and air management.
Control system has following main functions:
Pressure regulation of steam behind steam turbine by control valve
Regulation of output electric power of generator by control valve
Speed regulation of steam turbine by control valve
Manage the automatic cooling, lubrication of the bearings by oil pump and cooling of oil vent with
adjustable speed - based on requested temperature of oil
Measurement of operation values and all outher output values
Synchronization of steam turbine to nominal speed and safe connection to network, or disconnection
from network
Manages any safe shut-down of steam turbine in case of malfunction or emergency state
Signalization of errors and warnings
Emergency shut-down of steam turbine in case:
overload of maximal speed
overload of maximal current, voltage, power
activation of emergency button
error on sensors providing for regulation and controlling of critical values

S2E 110 kWe Module Installation at Dalkia Referencesite and training


center

Germany

Hungary

Israel

Herriotstrasse 1
Frankfurt am Main
60528
Germany
Tel: +49-32221-090-045

Gvadnyi utca 29-31


Budapest
1144
Hungary
Tel: +36-1-300-4001

Haogen 4
Herzliya
46551
Israel
Tel: +972-3-915-0935

7/23/2013

Вам также может понравиться