Вы находитесь на странице: 1из 4

ProceduretoSetupWorkstations(NT)

forAccesstoFAGORCNC8055/ABCwithTCP/IP:
1. SetupFagorCNC8055HDEMachineParametersexamplebelow:
P0 (HDDIR)=C:\CNC\USER
P2 (CNID)=NLSCNC1(nameofthemachineinplant)
P3 (CNGROUP)=WORKGROUP
P6 (CNHDDIR1)=\CNC\USER(harddiskdirectory)
P21(SERUNI2)=E
P22(DNCEACT)=1
P23(IPTYPE)=0
P24(DIRIP)=172.16.1.81(IPaddressofCNC)
P25(NETMASK)=255.255.255.0(SubnetMask)
P26(IPGATWAY)=172.16.1.XX(IPofDefaultGateway)
P27(IPSWDNC)=172.16.1.80(IPaddressofcomputerwith
WINDNC)
*P28(IPSNFS)=172.16.1.80(IPaddressofcomputerwith
remoteharddrive)
*P29(IPRNFS)=/C

****P28andP29isonlyusedforRemoteHardDrive.Iftheremoteharddrivewillnot
beusedleavetheparametersindefault.Youwillseeaerroronstartupcommunication
errorwithharddrive.ThiswillappearuntilyouinstallthesoftwareonyourPCneeded
forremoteharddrivecommunication.
2. CheckingcommunicationwithCNC:
LoginasAdministratoronyourPC.
RightclickonSTARTthenselectRUN.
UnderopentypeCMDthenpressenterorexecutethecommandpromptfrom
yourprograms.
OncethecommandpromptisopentypeinPINGfollowedbyparameter24.
Example:ping172.16.1.81 (Ifconnectionismadeyouwillseethefollowing)
Replyfrom172.16.1.81:bytes=32time=8msTTL=255
Replyfrom172.16.1.81:bytes=32time=3msTTL=255
Replyfrom172.16.1.81:bytes=32time=4msTTL=255
Replyfrom172.16.1.81:bytes=32time=8msTTL=255
SetupWINDNC4.1tocommunicatewithCNCthruTPC/IP.

8040/8055 ETHERNETSETUPANDCOMMUNICATION
***Note:Usemustuseacrossovercableforapointtopointconnection.Ifyouare
connectingtoHUByoumustuseastraightthrucable.
Installationofsoftware
Gotothefollowingwebsite: www.fagorautomation.com anddownloadthefree
copyofWINDNC.
OnceyouhavedownloadedthefiledoubleclickonWinDNC_V04_01.exe
andfollowtheinstructions
Setupofsoftware
GotostartandselectfromthelistWinDncver4.1
OncethesoftwareisopengotoOPTIONS
UnderFILESENDINGselectfileloading+deleting
Clickthecheckmarkicon
Goto SETUP
Clickon NEW
UnderNAMEclickonNEWandenteraname.Example8040Mthenpress
ENTER.
UnderMODEL selectthetypeofcontrolthatyouareworkingwith.Example
8050M/8055M.YouwouldselectthisoptionforaCNC8040M.
UnderTYPEselectNetworkNode.
Noneedtodoanythingwithconnectonstartup.
UnderIPADDRESS,UsethevalueofEthernetparameter24.
example 172.16.1.81
DoubleclickunderWORKFOLDERandnavigatetoc:/fagor/windnc/work.
WhiletheWorkfolderishighlightedclickon NEW.Typeinthenameofthe
folderwhereallofyourinformationwillbesavedto.Examplemachine

Oncethefoldermachinehasbeencreated,youmustclickselect. Thework
foldershouldnowreadasc:/fagor/windnc/work/machine
ClicktheOKicon
Underdeviceshighlight8040M,thenclickon SELECT,thenclickCONNECT
****Thescreenshouldlooklikethis:

****notethisonlyneedtobecreatedonce.Youcannowgotoany8040M/8050M/
8055Mcontrolandestablishcommunication.
SetupofparametersonCNC
GototheGcodesideofcontrol.Pressshiftthenescapetochangebetween
GCodeandconversational.
FromtheMAINMENUpressF7(+)
Goto MACHINEPARAMETERS(F4)
GotoSERIAL PARAMETERS(F3)
SelectETHERNET(F3)

****Note:Theparametersshouldbemodifiedtothefollowing:

****Oncetheparametershavebeenmodifiedmakesureyourestartthecontrol,sothe
parameterstakeeffect.
****DescriptionofoptionsforWINDNCcanbefoundinthefollowingdirectoryof
yourcomputer:C:\Fagor\Help\WinDnc\English\WinDNC.html