Вы находитесь на странице: 1из 143

ZXG10 ISMG

Operation & Maintenance Center

Command Manual
Version 6.10

ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900 800-9830-9830
Fax: (86) 755 26772236
URL: http://support.zte.com.cn
E-mail: doc@zte.com.cn

LEGAL INFORMATION
Copyright 2006 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History
Date

Revision No.

Serial No.

Reason for Issue

June 15, 2008

R1.0

sjzl20081894

First Edition

ZTE CORPORATION
Values Your Comments & Suggestions!
Your opinion is of great value and will help us improve the quality of our product
documentation and offer better services to our customers.
Please fax to (86) 755-26772236 or mail to Technical Delivery Department, ZTE
University, Dameisha, Yantian District, Shenzhen, Guangdong, P. R. China 518083.
Thank you for your cooperation!
Document
Name

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Product Version

V6.10

Document Revision
Number

Serial No.

sjzl20081894

Equipment
Installation Date

R1.0

Presentation:
(Introductions, Procedures, Illustrations, Completeness, Level of Detail, Organization,
Appearance)
Good
Your evaluation
of this
documentation

Fair

Average

Poor

Bad

N/A

Accessibility:
(Contents, Index, Headings, Numbering, Glossary)
Good

Fair

Average

Poor

Bad

N/A

Intelligibility:
(Language, Vocabulary, Readability & Clarity, Technical Accuracy, Content)
Good

Fair

Average

Poor

Bad

N/A

Please check the suggestions which you feel can improve this documentation:
Improve the overview/introduction

Your
suggestions for
improvement of
this
documentation

Make it more concise/brief

Improve the Contents

Add more step-by-step procedures/tutorials

Improve the organization

Add more troubleshooting information

Include more figures

Make it less technical

Add more examples

Add more/better quick reference aids

Add more detail

Improve the index

Other suggestions
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
# Please feel free to write any comments on an attached sheet.

If you wish to be contacted regarding your comments, please complete the following:
Name

Company

Postcode

Address

Telephone

E-mail

This page is intentionally blank.

Contents
About This Manual ............................................................ i
Purpose ................................................................................ i
Intended Audience ................................................................. i
Prerequisite Skill and Knowledge .............................................. i
What Is in This Manual ........................................................... i
Related Documentation.......................................................... ii
Conventions ......................................................................... ii
How to Get in Touch............................................................. iii

Chapter 1.......................................................................... 1
Overview .......................................................................... 1
Command Format ...........................................................1
Command Parameter Types ..............................................2
Command Compilation .....................................................3
Network Management MML Terminal ..................................4
Access to MML Terminal Interface............................................ 4
Configuring Preferences ......................................................... 6

Chapter 2.......................................................................... 9
Single Command Processing ........................................... 9
Overview .......................................................................9
Commands................................................................... 11
External Cell Configuration ................................................... 11
Cell Configuration ............................................................... 25
Configure cell object............................................................ 46

Appendix A ................................................................... 127


Abbreviations ............................................................... 127
Appendix B ................................................................... 129
Figures.......................................................................... 129

Tables ...........................................................................131
Index ............................................................................133

About This Manual


Purpose
This manual provides System commands used for performance
management, fault management, security management and
other system tools. This manual explains each command with its
function, syntax, input and output parameters.

Intended Audience
This document is intended for engineers and technicians who
perform command operation activities on ZXG10 ISMG.

Prerequisite Skill and Knowledge


To use this document effectively, users should have a general
understanding of wireless telecommunications technology.

What Is in This Manual


This manual contains the following chapters:
TABLE 1 - CHAPTER SUMMARY

Chapter

Summary

Chapter 1, Overview

Introduces command format, command


parameter type, command compiling key
points, and Network Management MML
terminal.

Chapter 2, Single
Command Processing

Mainly introduces processing steps of


single command and description of
different commands.

Appendix A,
Abbreviation

Lists all abbreviations used in this manual.

Appendix B

Lists all the figures and tables in this


manual.

Figures and Tables

Confidential and Proprietary Information of ZTE CORPORATION

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Chapter

Summary

Index

Lists the index of this manual.

Related Documentation
The following documentation is related to this manual:
ZXG10 ISMG (V6.10) Operation & Maintenance Center
Documentation Guide

ZXG10 ISMG (V6.10) Operation & Maintenance Center


Operation Manual (Configuration Management)

ZXG10 ISMG (V6.10) Operation & Maintenance Center


Operation Manual (Radio Parameters)

ZXG10 ISMG (V6.10) Operation & Maintenance Center


Operation Manual (Diagnosis and Test)

ZXG10 ISMG (V6.10) Operation & Maintenance Center


Software Installation Manual

Conventions
Typographical
Conventions

ZTE documents employ the following typographical conventions.


TABLE 2 - TYPOGRAPHIC AL CONVENTIONS

Typeface

Meaning

Italics

References to other Manuals and documents.

Quotes

Links on screens.

Bold

Menus, menu options, function names, input


fields, radio button names, check boxes, dropdown lists, dialog box names, window names.

CAPS

Keys on the keyboard and buttons on screens


and company name.

Constant width

Text that you type, program code, files and


directory names, and function names.

[]

Optional parameters.

{}

Mandatory parameters.

Select one of the parameters that are delimited


by it.
Note: Provides additional information about a
certain topic.
Checkpoint: Indicates that a particular step needs
to be checked before proceeding further.

ii

Confidential and Proprietary Information of ZTE CORPORATION

About This Manual

Typeface

Meaning
Tip: Indicates a suggestion or hint to make things
easier or more productive for the reader.

Mouse
Operation
Conventions

TABLE 3 - MOUSE OPERATION CONVENTIONS

Typeface

Meaning

Click

Refers to clicking the primary mouse button (usually


the left mouse button) once.

Double-click

Refers to quickly clicking the primary mouse button


(usually the left mouse button) twice.

Right-click

Refers to clicking the secondary mouse button


(usually the right mouse button) once.

Drag

Refers to pressing and holding a mouse button and


moving the mouse.

How to Get in Touch


The following sections provide information on how to obtain
support for the documentation and the software.
Customer
Support

Documentation
Support

If you have problems, questions, comments, or suggestions


regarding
your
product,
contact
us
by
e-mail
at
support@zte.com.cn. You can also call our customer support
center at (86) 755 26771900 and (86) 800-9830-9830.
ZTE welcomes your comments and suggestions on the quality
and usefulness of this document. For further questions,
comments, or suggestions on the documentation, you can
contact us by e-mail at doc@zte.com.cn; or you can fax your
comments and suggestions to (86) 755 26772236. You can also
browse our website at http://support.zte.com.cn, which contains
various interesting subjects like documentation, knowledge base,
forum and service request.

Confidential and Proprietary Information of ZTE CORPORATION

iii

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

This page is intentionally blank.

iv

Confidential and Proprietary Information of ZTE CORPORATION

Chapter

Overview

This chapter introduces command format, command parameter


type, command compiling key points, and Network Management
MML terminal.

Command Format
Command composition format is as follows:
Command Prompt: Mandatory parameter, [Optional Parameter];
Command Example:
[OLDPASSWORD =
<PASSWORD>];

SET PASSWORD: NAME = <NAME>,


<OLDPASSWORD>], [PASSWORD =

Where, positions of mandatory


parameter can be interchanged.

parameter

and

optional

Command Prompt
Command prompt, also named mnemonic, is composed of
words with command function such as SHOW USER, which
can be used to inquire the basic information of user.

Mandatory parameter
Mandatory parameter is the mandatory part of a command,
separated from command prompt by a colon. Mandatory
parameter is marked with red asterisk on graphic interface.
Under TELNET mode, the system prompts it in sequence. If a
command has mandatory parameter, user must input the
mandatory parameter, to run the command normally.

Optional parameter
Optional parameter is an optional input for user. After user
inputs command prompt and mandatory parameter, system
automatically fills in default value, and run the command.

Confidential and Proprietary Information of ZTE CORPORATION

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

End of command
By default, a command ends with semicolon. Under TELNET
mode, if user directly runs the command without a semicolon,
after inputting command prompt and all parameters, system
automatically adds ; to the command and execute it. For
the command under Network Management login mode, when
the user clicks Execute button or press F5 key, system
automatically adds ; at the end of the command, and
execute it.

Command Parameter Types


1. Numeric
Numeric parameter can be divided into INTEGER and FLOAT.

There are two types of INTEGER:


f

INTEGER number

Parameter Argument INTEGER.


INTEGER number doesnt include any separator, but
Parameter Argument INTEGER includes separators &, &&,
-, &&- between INTEGER numbers.

There are two types of FLOAT:


f

FLOAT number,

Parameter Argument FLOAT.


FLOAT number doesnt include any separator, but
Parameter Argument FLOAT includes separator &
between FLOAT numbers.

2. BOOLEAN
BOOLEAN value can be T (TRUE) or F (FALSE).
3. IDENTIFIER
There are two types of Identifier.
f

Basic Identifier

Parameter Argument Identifier


Basic identifier type includes normal identifier, alphabet
and number. Basic identifier starts with an alphabet. For
example: abc123.
Parameter Argument type identifier includes a separator
& between two basic identifiers. For example:
abc123&abc123.

4. Enumeration
There are two types of Enumerations:
2

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 1 - Overview
f

Normal enumeration

Parameter Argument enumeration

Normal enumerative items are separated by ,.


Parameter Argument enumeration includes a separator
& between normal enumerative items.

5. Date
Representation of date: YYYY-MM-DD.
6. Time
It includes second level time type (representation of second
level time type: HH-MI-SS) and minute level time type
(representation of minute level time type: HH-MI).
7. Temperature
Decimal float number + postfix C.
8. Percent
Decimal float number + postfix %.
9. String
There are two types of strings:
f

Normal string

Parameter Argument string


Normal string type is enclosed by double quotation marks.
Parameter Argument string includes & between normal
strings.

10. Complex
It is a special parameter type combined by multiple
parameter types.

Command Compilation
Command introduction in this manual is shown in Table 4.
TABLE 4 - COMM AND COMPILATION

Item

Description

Example

Prompt

Title of each
command is its
command prompt

DEL CHAN

Confidential and Proprietary Information of ZTE CORPORATION

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Item

Description

Example

Command
format

Command input
format, represented
in bold font, where
optional parameters
are marked by square
brackets

DEL
CHAN:[SUBNETID=<SUBNET
ID>][,CONFSETID=<CONFSE
TID>][,BSCID=<BSCID>][,S
ITEID=<SITEID>][,BTSID=<
BTSID>][,TRXID=<TRXID>][
,TSID=<TSID>];

Input
Parameter

Describes meaning,
value range, and
filling description for
all parameters

Omitted

Output
Parameters

Describes the normal


output parameters

Omitted

Enumeratio
n
Description

Describes the
different enumeration
parameter options in
command format

Omitted

Example

Shows examples for


normal execution in
network
administration
system, divided into
input and output
portions

Remarks

Other information
related with command

DEL CHAN:SUBNETID=1,
CONFSETID=0,BSCID=1,
SITEID=1,BTSID=1,TRXID=1
,
TSID=0;
Omitted

Network Management MML


Terminal
Access to MML Terminal Interface
Purpose
Prerequisites

To access Network Management MML terminal interface.


System operation is in normal status, and it has successfully
logged in server.

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 1 - Overview

Operation
Steps

1. After successfully logging into Network Management system,


select View MML Terminal, as shown in Figure 1.
FIGURE 1 - SELECT MML TERMINAL

2. Click MML Terminal, as shown in Figure 2.

Confidential and Proprietary Information of ZTE CORPORATION

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual


FIGURE 2 - MML TERMINAL INTERFACE

Configuring Preferences
Purpose

To configure the relevant system parameters

Prerequisites

System operation is in normal status, and MML Terminal


interface is started.

Operation
Steps

1. Select MML Terminal Preferences on MML Terminal


interface, as shown in Figure 3.

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 1 - Overview
FIGURE 3 - CONFIGURE PREFERENCES 1

2. Preferences interface pops up, as shown in Figure 4.


FIGURE 4 - CONFIGURE PREFERENCES 2

3. Configure the record number to be saved on History


Command, Command Execute Result, Message Report, and
Batch Execute Result labels.
4. Check the Automatic Save check box to save the history
records. Browse button is enabled, as shown in Figure 5.

Confidential and Proprietary Information of ZTE CORPORATION

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual


FIGURE 5 - CONFIGURE PREFERENCES 3

5. Click Browse, the system pops up Save dialog box, in which


select the path to save the history record, then click Save
button.
6. Click Ok button in Preferences interface to finish the
preferences setting.

Confidential and Proprietary Information of ZTE CORPORATION

Chapter

Single Command
Processing

This chapter mainly introduces the processing steps of single


command, and description of different commands.

Overview
There are two modes to input command for single command
processing:

Input command manually in command prompt box. This


method is suitable for the persons who are very familiar with
command.
In command topology tree of [MML Terminal] interface,
select operation object and command, and fill in necessary
parameters in parameter information box.

The operation steps of single command are described in the


following sections.
1. In MML Terminal interface, move cursor to command
prompt box and input command, as shown in Figure 6.

Confidential and Proprietary Information of ZTE CORPORATION

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

FIGURE 6 - INPUT BY COMMAND PROMPT BOX

In second command input mode, check the command topology


tree, select the command to execute, and then fill in mandatory
parameters in parameter information blank, as shown in Figure
7.

10

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

FIGURE 7 - SELECT COMM AND / FILL IN P ARAMETERS

Caution:
The parameters with red asterisk are the mandatory fields, and
must be filled in to execute the command. Command object ID
to be executed must be filled in correctly, otherwise association
file error may occur and system could not find the object to
execute the command.
2. Click
. Command execution result will be
displayed above the command prompt box.
Note:
Function Key F5 can also be used to execute the command.

Commands
Command description is as follows.

External Cell Configuration


Create GERAN External Cell
Prompt

ADD ECELL

Confidential and Proprietary Information of ZTE CORPORATION

11

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Format

Input
Parameters

12

ADD
ECELL:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,B
SCID=<BSCID>,ECELLID=<ECELLID>[,USERLABEL=<USERLAB
EL>],FREQBAND=<FREQBAND>,BCCHARFCN=<BCCHARFCN>,
MCC=<MCC>,MNC=<MNC>,LAC=<LAC>,CI=<CI>,NCC=<NCC
>,BCC=<BCC>,CELLTYPE=<CELLTYPE>[,PSSUPPORT=<PSSUPP
ORT>][,EXC_ACC=<EXC_ACC>][,LSA_ID=<LSA_ID>][,RAC=<
RAC>][,CELLBARAC2=<CELLBARAC2>][,RXLEVASMIN=<RXLEV
ASMIN>][,MSTXMAXCCH=<MSTXMAXCCH>][,RESELOFF=<RES
ELOFF>][,TEMPOFFSET=<TEMPOFFSET>][,PENALTIME=<PENAL
TIME>][,HCS_EXIST=<HCS_EXIST>][,HCS_THR=<HCS_THR>]
[,PRIOCLASS=<PRIOCLASS>];
Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configuration Set ID

Int

BSCID

BSC ID

Int

ECELLID

2G External Cell ID

Int

USERLABEL

User Label

String

FREQBAND

Frequency Band

Enumeration

BCCHARFCN

Cell BCCH Frequency

Int

MCC

Mobile Country Code

Int

MNC

Mobile Network Code

Int

10

LAC

Location Area Code

Int

11

CI

Cell ID

Int

12

NCC

Network Color Code

Int

13

BCC

BS Color Code

Int

14

CELLTYPE

Cell Type

Enumeration

15

PSSUPPORT

Support GRPS

Enumeration

16

EXC_ACC

Allow SoLSA special


access rights mobile

Int

17

LSA_ID

LSA ID

Int

18

RAC

Routing Area Code

Int

19

CELLBARAC2

Cell Reselection
Status

Int

20

RXLEVASMIN

GPRS Minimum
Access Level

Int

21

MSTXMAXCCH

GPRS Initial Maximum


Access Level

Int

22

RESELOFF

Reselect Offset

Int

23

TEMPOFFSET

Reselect Temporary
Offset

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

24

PENALTIME

Reselect penal time

Int

25

HCS_EXIST

Use HCS parameter

Int

26

HCS_THR

HCS threshold

Int

27

PRIOCLASS

HCS priority class

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~65535

1-1

0~40

Output
Parameters

Default

Instance
Count

""

1-1

FREQBAND_0

1-1

0~1023

1-1

0~999

460

1-1

0~999

1-1

10

1~65535

1-1

11

0~65535

1-1

12

0~7

1-1

13

0~7

1-1

14

CELLTYPE_1

1-1

15

BOOLEAN_NO

1-1

16

0~1

1-1

17

0~16777215

1-1

18

0~255

1-1

19

0~1

1-1

20

0~63

12

1-1

21

0~31

1-1

22

0~31

1-1

23

0~7

1-1

24

0~31

1-1

25

0~1

1-1

26

0~31

1-1

27

0~7

1-1

Description of output parameters is as follows:

Confidential and Proprietary Information of ZTE CORPORATION

13

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Enumeration
Description

No.

Name

Type

Notes

Instanc
e Count

DETAIL

String

Details

1-1

Cell band information is as follows:

Macro Name

Meaning

FREQBAND_0

GSM900

FREQBAND_1

EXT900

FREQBAND_2

DCS1800

FREQBAND_4

GSM850

FREQBAND_7

PCS1900

BOOLEAN information is as follows:


Macro Name

Meaning

BOOLEAN_NO

No

BOOLEAN_YES

Yes

Cell type information is as follows:


Macro Name

Meaning

CELLTYPE_0

Umbrella cell

CELLTYPE_1

Macro cell

CELLTYPE_2

Micro cell

CELLTYPE_3

Pico cell

CELLTYPE_4

Extended range cell

Example

ADD
ECELL:SUBNETID=1,CONFSETID=0,BSCID=1,ECELLID=1,USERL
ABEL="",FREQBAND=FREQBAND_0,BCCHARFCN=1,MCC=460,M
NC=0,LAC=1,CI=0,NCC=0,BCC=0,CELLTYPE=CELLTYPE_1,PSSU
PPORT=BOOLEAN_NO,EXC_ACC=0,LSA_ID=0,RAC=0,CELLBARA
C2=0,RXLEVASMIN=12,MSTXMAXCCH=5,RESELOFF=0,TEMPOFF
SET=0,PENALTIME=0,HCS_EXIST=0,HCS_THR=0,PRIOCLASS=0;

Remarks

PCS1900 cannot be selected for cell band when BSC supports


DCS1800, and DCS1800 cannot be selected when BSC supports
PCS1900.

Delete GERAN External Cell


Prompt

14

DEL ECELL

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Format

Input
Parameters

Output
Parameters

Example

DEL
ECELL:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>
][,BSCID=<BSCID>][,ECELLID=<ECELLID>];
Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

ECELLID

External Cell ID

Int

No.

Range

Default

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~65535

1-1

Instance
Count

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL ECELL:SUBNETID=1,CONFSETID=0,BSCID=1,ECELLID=1;

Display GERAN External Cell


Prompt

SHW ECELL

Format

SHW
ECELL:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>
][,BSCID=<BSCID>][,ECELLID=<ECELLID>][,PARAMS=<PARA
MS>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

15

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

No.

Name

Notes

Type

BSCID

BSC ID

Int

ECELLID

External Cell ID

Int

PARAMS

Parameter List

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~65535

1-1

0~1000

Instance
Count

Default

""

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

29

INFO

Complex

Query Result

1-10000

SHW
ECELL:SUBNETID=1,CONFSETID=0,BSCID=1,ECELLID=1,PARA
MS=" ";

Modify GERAN External Cell


Prompt

SET ECELL

Format

SET
ECELL:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>
][,BSCID=<BSCID>][,GERANECELLID=<GERANECELLID>][,USE
RLABEL=<USERLABEL>][,FREQBAND=<FREQBAND>][,BCCHAR
FCN=<BCCHARFCN>][,MCC=<MCC>][,MNC=<MNC>][,LAC=<L
AC>][,CI=<CI>][,NCC=<NCC>][,BCC=<BCC>][,CELLTYPE=<C
ELLTYPE>][,PSSUPPORT=<PSSUPPORT>][,EXC_ACC=<EXC_AC
C>][,LSA_ID=<LSA_ID>][,RAC=<RAC>][,CELLBARAC2=<CELL
BARAC2>][,RXLEVASMIN=<RXLEVASMIN>][,MSTXMAXCCH=<M
STXMAXCCH>][,RESELOFF=<RESELOFF>][,TEMPOFFSET=<TEM
POFFSET>][,PENALTIME=<PENALTIME>][,HCS_EXIST=<HCS_E
XIST>][,HCS_THR=<HCS_THR>][,PRIOCLASS=<PRIOCLASS>];

Input
Parameters

16

Description of input parameters is as follows:

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

GERANECELLID

External Cell ID

Int

USERLABEL

User Label

String

FREQBAND

Frequency Band

Enumeration

BCCHARFCN

Cell BCCH Frequency

Int

MCC

Mobile Country Code

Int

MNC

Mobile Network Code

Int

10

LAC

Location Area Code

Int

11

CI

Cell ID

Int

12

NCC

Network Color Code

Int

13

BCC

BS Color Code

Int

14

CELLTYPE

Cell Type

Enumeration

15

PSSUPPORT

Support GPRS

Enumeration

16

EXC_ACC

Allow SoLSA special


access mobile

Int

17

LSA_ID

LSA ID

Int

18

RAC

Routing Area Code

Int

19

CELLBARAC2

Cell Reselection Status

Int

20

RXLEVASMIN

GPRS MIN ACCESS


LEVEL

Int

21

MSTXMAXCCH

GPRS Max Initial


Access Level

Int

22

RESELOFF

Reselection Offset

Int

23

TEMPOFFSET

Reselect Temporary
Offset

Int

24

PENALTIME

Reselect Penalty Time

Int

25

HCS_EXIST

Usage HCS Parameter

Int

26

HCS_THR

HCS STRENGTH
THRESHOLD

Int

27

PRIOCLASS

HCS PRIORITY

Int

Default

Instance
Count

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

Confidential and Proprietary Information of ZTE CORPORATION

17

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Default

Range

1~65535

1-1

0~40

1-1

Output
Parameters

Enumeration
Description

18

Instance
Count

No.

1-1

0~1023

1-1

0~999

1-1

0~999

1-1

10

1~65535

1-1

11

0~65535

1-1

12

0~7

13

0~7

1-1

14

0~4

1-1

15

0~2

1-1

16

0~1

1-1

17

0~16777215

1-1

18

0~255

1-1

19

0~1

1-1

20

0~63

1-1

21

0~31

1-1

22

0~31

1-1

23

0~7

1-1

24

0~31

1-1

25

0~1

1-1

26

0~31

1-1

27

0~7

1-1

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Cell band information is as follows:

Macro Name

Meaning

FREQBAND_0

GSM900

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Macro Name

Meaning

FREQBAND_1

EXT900

FREQBAND_2

DCS1800

FREQBAND_4

GSM850

FREQBAND_7

PCS1900

BOOLEAN information is as follows:


Macro Name

Meaning

BOOLEAN_NO

No

BOOLEAN_YES

Yes

Cell type information is as follows:


Macro Name

Meaning

CELLTYPE_0

Umbrella Cell

CELLTYPE_1

Macro Cell

CELLTYPE_2

Micro Cell

CELLTYPE_3

Pico Cell

CELLTYPE_4

Extended Cell

Example

SET
ECELL:SUBNETID=1,CONFSETID=0,BSCID=1,ECELLID=1,USERL
ABEL="0",FREQBAND= ,BCCHARFCN=0,MCC=0,MNC=0,LAC=1,
CI=0,NCC=0,BCC=0,CELLTYPE=0,PSSUPPORT=0,EXC_ACC=0,L
SA_ID=0,RAC=0,CELLBARAC2=0,RXLEVASMIN=0,MSTXMAXCCH
=0,RESELOFF=0,TEMPOFFSET=0,PENALTIME=0,HCS_EXIST=0,
HCS_THR=0,PRIOCLASS=0;

Remarks

PCS1900 cannot be selected for cell band when BSC supports


DCS1800, DCS1800 cannot be selected when BSC supports
PCS1900.

Create UTRAN External Cell


Prompt

ADD EC3G

Format

ADD
EC3G:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,BS
CID=<BSCID>,EC3GID=<EC3GID>[,USERLABEL=<USERLABEL
>],MCC=<MCC>,MNC=<MNC>,RNC_ID=<RNC_ID>,C_ID=<C_
ID>,LAC=<LAC>,ARFCN3G=<ARFCN3G>,SCCODECELLPARA=<
SCCODECELLPARA>,DIVERSITY=<DIVERSITY>[,BANDWIDTH3G
=<BANDWIDTH3G>][,SYNCCASETSTD=<SYNCCASETSTD>],CE
LLTYPE3G=<CELLTYPE3G>;

Input
Parameters

Description of input parameters is as follows:

Confidential and Proprietary Information of ZTE CORPORATION

19

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

20

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

EC3GID

UTRAN External
Cell ID

Int

USERLABEL

User Label

String

MCC

Mobile Country
Code

Int

MNC

Mobile Network
Code

Int

RNC_ID

UTRAN adjacent
cell RNC ID

Int

C_ID

UTRAN adjacent
cell ID

Int

10

LAC

Location Area Code

Int

11

ARFCN3G

UTRAN adjacent
cell frequency

Int

12

SCCODECELLPARA

FDD scrambling or
TDD cell parameter

Int

13

DIVERSITY

URTANE adjacent
cell transmission
diversity

Enumeration

14

BANDWIDTH3G

UTRAN adjacent
cell bandwidth

Int

15

SYNCCASETSTD

Apply Sync Case

Int

16

CELLTYPE3G

UTRAN Cell Type

Enumeration

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~65535

1-1

0~40

""

1-1

0~999

460

1-1

0~999

1-1

0~4095

1-1

0~65535

1-1

10

1~65535

1-1

11

0~65535

1-1

Default

Confidential and Proprietary Information of ZTE CORPORATION

Instance
Count

Chapter 2 - Single Command Processing

No.

Range

Default

Instance
Count

12

0~511

1-1

BOOLEAN_NO

1-1

13
14

0~1

1-1

15

0~1

1-1

CELLTYPE3G_0

1-1

16

Output
Parameters

Enumeration
Description

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

BOOLEAN information is as follows:

Macro Name

Meaning

BOOLEAN_NO

No

BOOLEAN_YES

Yes

UTRAN cell type information is as follows:


Macro Name

Meaning

CELLTYPE3G_0

FDD

CELLTYPE3G_1

TDD

Example

ADD
EC3G:SUBNETID=1,CONFSETID=0,BSCID=1,EC3GID=1,USERLA
BEL="",MCC=460,MNC=0,RNC_ID=0,C_ID=0,LAC=1,ARFCN3G
=1,SCCODECELLPARA=0,DIVERSITY=BOOLEAN_NO,BANDWIDT
H3G=0,SYNCCASETSTD=0,CELLTYPE3G=CELLTYPE3G_0;

Remarks

ARFCN3G:

FDD cell: 9612~9888, 10562~10838;

3.84McpsTDD Cell: 9262~9638, 9662~9938, 10062~10113;

1.28 Mcps TDD Cell: 9254~9646, 9654~9946, 10054~10121.

Delete UTRAN External Cell


Prompt

DEL EC3G

Confidential and Proprietary Information of ZTE CORPORATION

21

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Format

Input
Parameters

Output
Parameters

Example

DEL
EC3G:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>]
[,BSCID=<BSCID>][,EC3GID=<EC3GID>];
Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet
ID

Int

CONFSETID

Configure
Set ID

Int

BSCID

BSC ID

Int

EC3GID

UTRAN
External
Cell ID

Int

No.

Range

Default

Instance Count

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~65535

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL EC3G:SUBNETID=1,CONFSETID=0,BSCID=1,EC3GID=1;

Display UTRAN External Cell


Prompt

SHW EC3G

Format

SHW
EC3G:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>]
[,BSCID=<BSCID>][,EC3GID=<EC3GID>][,PARAMS=<PARAMS
>];

Input
Parameters

22

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Example

No.

Name

Notes

Type

BSCID

BSC ID

Int

EC3GID

UTRAN External Cell ID

Int

PARAMS

Parameter List

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~65535

1-1

0~1000

Default

""

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

19

INFO

Complex

Query Result

1-10000

SHW
EC3G:SUBNETID=1,CONFSETID=0,BSCID=1,EC3GID=1,PARAM
S=" ";

Modify UTRAN External Cell


Prompt

SET EC3G

Format

SET
EC3G:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>]
[,BSCID=<BSCID>][,EC3GID=<EC3GID>][,USERLABEL=<USER
LABEL>][,MCC=<MCC>][,MNC=<MNC>][,RNC_ID=<RNC_ID>]
[,C_ID=<C_ID>][,LAC=<LAC>][,ARFCN3G=<ARFCN3G>][,SCC
ODECELLPARA=<SCCODECELLPARA>][,DIVERSITY=<DIVERSIT
Y>][,BANDWIDTH3G=<BANDWIDTH3G>][,SYNCCASETSTD=<S
YNCCASETSTD>][,CELLTYPE3G=<CELLTYPE3G>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

23

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

No.

Name

Notes

Type

BSCID

BSC ID

Int

EC3GID

UTRAN External Cell


ID

Int

USERLABEL

User Label

String

MCC

Mobile Country Code

Int

MNC

Mobile Network Code

Int

RNC_ID

UTRAN adjacent cell


RNC ID

Int

C_ID

UTRAN adjacent cell


ID

Int

10

LAC

Location Area Code

Int

11

ARFCN3G

UTRAN adjacent cell


frequency

Int

12

SCCODECELLPARA

FDD scrambling or
TDD cell parameter

Int

13

DIVERSITY

URTANE adjacent cell


transmission diversity

Enumeration

14

BANDWIDTH3G

UTRAN adjacent cell


bandwidth

Int

15

SYNCCASETSTD

Apply Sync Case

Int

16

CELLTYPE3G

UTRAN Cell Type

Enumeration

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~65535

1-1

0~40

1-1

0~999

1-1

0~999

1-1

0~4095

1-1

0~65535

1-1

10

1~65535

1-1

11

0~65535

1-1

12

0~511

1-1

Default

13

24

Instance
Count

1-1

14

0~1

1-1

15

0~1

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Range

Default

16

Output
Parameters

Enumeration
Description

Instance
Count
1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

BOOLEAN information is as follows:

Macro Name

Meaning

BOOLEAN_NO

No

BOOLEAN_YES

Yes

UTRAN cell type information is as follows:

Example

Macro Name

Meaning

CELLTYPE3G_0

FDD

CELLTYPE3G_1

TDD

SET
EC3G:SUBNETID=1,CONFSETID=0,BSCID=1,EC3GID=1,USERLA
BEL="0",MCC=0,MNC=0,RNC_ID=0,C_ID=0,LAC=1,ARFCN3G=
0,SCCODECELLPARA=0,DIVERSITY= ,BANDWIDTH3G=0,SYNCC
ASETSTD=0,CELLTYPE3G=CELLTYPE3G_0;

Cell Configuration
Delete Cell Command
Prompt

DEL BTS

Format

DEL
BTS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

25

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

No.

Name

Notes

Type

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

Default

Instance
Count

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL
BTS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1;

Show Cell Command


Prompt

SHW BTS

Format

SHW
BTS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,PA
RAMS=<PARAMS>];

Input
Parameters

26

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Example

No.

Name

Notes

Type

PARAMS

Parameter List

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

0~1000

Default

""

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

214

INFO

Complex

Query Result

1-10000

SHW
BTS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
PARAMS=" ";

Modify Cell Command


Prompt

SET BTS

Format

SET
BTS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,US
ERLABEL=<USERLABEL>][,CELLTYPE=<CELLTYPE>][,LAC=<LA
C>][,CI=<CI>][,NCC=<NCC>][,BCC=<BCC>][,FREQBAND=<F
REQBAND>][,SUBFREQBAND=<SUBFREQBAND>][,BCCHARFCN
=<BCCHARFCN>][,CAFREQNUM=<CAFREQNUM>][,CAARFCNLI
ST=<CAARFCNLIST>][,MRETRANS=<MRETRANS>][,TXINTEGER
=<TXINTEGER>][,CELLBARQUALIFY=<CELLBARQUALIFY>][,CE
LLBARACCESS=<CELLBARACCESS>][,CALLREESTABLISH=<CAL
LREESTABLISH>][,EMERGENCYCALL=<EMERGENCYCALL>][,AC
CESSCONTROL=<ACCESSCONTROL>][,IMSIADALLOWED=<IMS
IADALLOWED>][,CCCHCONF=<CCCHCONF>][,BSAGBLKRES=<
BSAGBLKRES>][,BSPAMFRAMS=<BSPAMFRAMS>][,T3212=<T3
212>][,DTXUPLINKBCCH=<DTXUPLINKBCCH>][,MSRADIOLKTM
OUT=<MSRADIOLKTMOUT>][,T3122=<T3122>][,MULBANDREP
ORT=<MULBANDREPORT>][,NCCPERMITTED=<NCCPERMITTED

Confidential and Proprietary Information of ZTE CORPORATION

27

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

>][,SMSCBUSED=<SMSCBUSED>][,RESELHYSTERESIS=<RESE
LHYSTERESIS>][,MSTXPWRMAXCCH=<MSTXPWRMAXCCH>][,A
DDITIONRESELPI=<ADDITIONRESELPI>][,NECI=<NECI>][,RXL
EVACCESSMIN=<RXLEVACCESSMIN>][,CELLRESELPI=<CELLRE
SELPI>][,RESELOFFSET=<RESELOFFSET>][,TEMPORARYOFFSET
=<TEMPORARYOFFSET>][,PENALTYTIME=<PENALTYTIME>][,PO
WEROFFSETIND=<POWEROFFSETIND>][,POWEROFFSET=<PO
WEROFFSET>][,ECSC=<ECSC>][,DRIND=<DRIND>][,DTXDWLI
NK=<DTXDWLINK>][,QUEUEIND=<QUEUEIND>][,PREEMPTION
IND=<PREEMPTIONIND>][,FORCEDHOIND=<FORCEDHOIND>][
,CANDIDATENUM=<CANDIDATENUM>][,CIPHERMODE=<CIPHE
RMODE>][,PREPROCESS=<PREPROCESS>][,FASTAVG=<FASTA
VG>][,FACCHCALLIND=<FACCHCALLIND>][,RESOURCETHS=<R
ESOURCETHS>][,CCCHLOADINDPRD=<CCCHLOADINDPRD>][,C
CCHLOADINDTHS=<CCCHLOADINDTHS>][,INTERFAVGPRD=<I
NTERFAVGPRD>][,INTERFBOUNDARY=<INTERFBOUNDARY>][,N
Y1=<NY1>][,CONFAILCRITERION=<CONFAILCRITERION>][,BS
RADIOLKTMOUT=<BSRADIOLKTMOUT>][,RXLEVTHS=<RXLEVT
HS>][,RXQUALTHS=<RXQUALTHS>][,T200=<T200>][,RXLEVQ
UALPRD=<RXLEVQUALPRD>][,T3105=<T3105>][,OVERLOADPR
D=<OVERLOADPRD>][,BCCHTRXSEQ=<BCCHTRXSEQ>][,AVGS
LOTS=<AVGSLOTS>][,CANBCCHEXCH=<CANBCCHEXCH>][,RA
CHBUSYTHS=<RACHBUSYTHS>][,EXCHLOCK=<EXCHLOCK>][,
HAVEEXCH=<HAVEEXCH>][,EXCHTRXID=<EXCHTRXID>][,CAN
SDCCHDYN=<CANSDCCHDYN>][,TAMAX=<TAMAX>][,TAALLO
WED=<TAALLOWED>][,CHANSELECTPRIO=<CHANSELECTPRIO
>][,PSSUPPORT=<PSSUPPORT>][,ADDRESPI2=<ADDRESPI2>]
[,EXC_ACC=<EXC_ACC>][,LSA_OFFSET=<LSA_OFFSET>][,PRI
O_THR=<PRIO_THR>][,LSA_ID=<LSA_ID>][,CELLSEQ=<CELL
SEQ>][,BCCHCHANIND=<BCCHCHANIND>][,PWRC=<PWRC>][
,CUROVERLEVEL=<CUROVERLEVEL>][,LASTBARREDCLASS=<L
ASTBARREDCLASS>][,DYNAHRENABLE=<DYNAHRENABLE>][,U
SECELLDYNHRPARA=<USECELLDYNHRPARA>][,HRTHS=<HRTH
S>][,SUBCELLUSED=<SUBCELLUSED>][,AMRFULLACS=<AMRF
ULLACS>][,AMRHALFACS=<AMRHALFACS>][,AMRTHRESHOLDS
=<AMRTHRESHOLDS>][,AMRHYSTERESIS=<AMRHYSTERESIS>
][,ISAMRNSCB=<ISAMRNSCB>][,ISAMRICM=<ISAMRICM>][,A
MRSTARTMODE=<AMRSTARTMODE>][,TFOSUPPORT=<TFOSUP
PORT>][,EMLPPTHS=<EMLPPTHS>][,USECELLEMLPPTHS=<USE
CELLEMLPPTHS>][,EMLPPBUSYNUM=<EMLPPBUSYNUM>][,CSRS
VRATE=<CSRSVRATE>][,ADMSTATE=<ADMSTATE>][,WORK=<
WORK>][,NSEI=<NSEI>][,BVCI=<BVCI>][,RAC=<RAC>][,UPU
UNIT=<UPUUNIT>][,DSP=<DSP>][,T3168=<T3168>][,T3192=
<T3192>][,DRXTIMEMAX=<DRXTIMEMAX>][,BSCVMAX=<BSCV
MAX>][,CTRACKTYPE=<CTRACKTYPE>][,ACCESSTYPE=<ACCES
STYPE>][,PANDEC=<PANDEC>][,PANINC=<PANINC>][,PANMA
X=<PANMAX>][,PBCCHBLKS=<PBCCHBLKS>][,PAGBLKRES=<P
AGBLKRES>][,PRACHBLKS=<PRACHBLKS>][,TXINT=<TXINT>][
,S=<S>][,MAXRETRANS=<MAXRETRANS>][,PERSISTLEV=<PER
SISTLEV>][,ACCCTRLCLASS=<ACCCTRLCLASS>][,ALPHA=<ALP
HA>][,T_AVG_W=<T_AVG_W>][,T_AVG_T=<T_AVG_T>][,PB=
<PB>][,PCMEASCHAN=<PCMEASCHAN>][,PSI4SEND=<PSI4SE
ND>][,N_AVG_I=<N_AVG_I>][,RXLEVASMIN=<RXLEVASMIN>]
[,MSTXMAXCCH=<MSTXMAXCCH>][,HCS_EXIST=<HCS_EXIST

28

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

>][,PRIOCLASS=<PRIOCLASS>][,HCS_THR=<HCS_THR>][,RES
ELOFF=<RESELOFF>][,RESELHYS=<RESELHYS>][,C31_HYST=
<C31_HYST>][,C32_QUAL=<C32_QUAL>][,RADACRETRY=<RA
DACRETRY>][,T_RESEL=<T_RESEL>][,RARESELHYS=<RARESE
LHYS>][,TEMPOFFSET=<TEMPOFFSET>][,PENALTIME=<PENALT
IME>][,SI3LOCATE=<SI3LOCATE>][,RACOLOR=<RACOLOR>][,
MEAORDER=<MEAORDER>][,CTRLORDER=<CTRLORDER>][,NC
NODRXPER=<NCNODRXPER>][,NCREPPERI=<NCREPPERI>][,N
CRERPERT=<NCRERPERT>][,EXMEAORDER=<EXMEAORDER>][,
EXTREPTYPE=<EXTREPTYPE>][,EXTREPPER=<EXTREPPER>][,S
PGCSUPORT=<SPGCSUPORT>][,PRIACTHR=<PRIACTHR>][,PSI
1REPPER=<PSI1REPPER>][,PSISTATIND=<PSISTATIND>][,CSC
HANSTHS=<CSCHANSTHS>][,SENDSPEED=<SENDSPEED>][,E
PAGEMODE=<EPAGEMODE>][,LOADPER=<LOADPER>][,OVLOA
DPER=<OVLOADPER>][,PCCCHINDTH=<PCCCHINDTH>][,RLTI
MEOUT=<RLTIMEOUT>][,PRACHBUSYT=<PRACHBUSYT>][,MEA
AVGSLOT=<MEAAVGSLOT>][,CHANGEMARK=<CHANGEMARK>]
[,EGPRSPACKETCHREQ=<EGPRSPACKETCHREQ>][,BEPPERIODU
P=<BEPPERIODUP>][,BEPPERIODDOWN=<BEPPERIODDOWN>]
[,DTMSUPPORT=<DTMSUPPORT>][,GTTPLAPDMNUM=<GTTPLA
PDMNUM>][,LINKQUAMEAMODE=<LINKQUAMEAMODE>][,IRSU
PPORTUP=<IRSUPPORTUP>][,PREEMPTIVETRANS=<PREEMPTIV
ETRANS>][,USFGRANULARITY=<USFGRANULARITY>][,EGPRSIN
ITATTSELT=<EGPRSINITATTSELT>][,GPRSINITATTSELT=<GPR
SINITATTSELT>][,INITATTACHEXCH=<INITATTACHEXCH>][,CC
NACTIVE=<CCNACTIVE>][,SISTATUSIND=<SISTATUSIND>][,E
XT_UTBF=<EXT_UTBF>][,ISSYNCUPU=<ISSYNCUPU>][,EXTDY
NALLOCSUPP=<EXTDYNALLOCSUPP>][,ULDELAYTIME=<ULDEL
AYTIME>][,DLDELAYTIME=<DLDELAYTIME>][,EXTULTBFTIME=
<EXTULTBFTIME>][,GPRSDLRRBPINTERVAL=<GPRSDLRRBPINT
ERVAL>][,EGPRSDLRRBPINTERVAL=<EGPRSDLRRBPINTERVAL>
][,GPRSULACKINTERVAL=<GPRSULACKINTERVAL>][,EGPRSULA
CKINTERVAL=<EGPRSULACKINTERVAL>][,ULMEASUREPERIOD=
<ULMEASUREPERIOD>][,STATUS=<STATUS>][,BCCHBAIND=<
BCCHBAIND>][,PHYCELL=<PHYCELL>][,HYBRIDOCCUSUPP=<H
YBRIDOCCUSUPP>][,ALLOWPSMOVE=<ALLOWPSMOVE>][,ALLO
WCSMOVE=<ALLOWCSMOVE>][,SFPREFERBUSYTHS=<SFPREFE
RBUSYTHS>][,OPPREFERBUSYTHS=<OPPREFERBUSYTHS>][,ST
ARTTRXPOWEROFF=<STARTTRXPOWEROFF>];
Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

USERLABEL

User Label

String

CELLTYPE

Cell Type

Enumeration

Confidential and Proprietary Information of ZTE CORPORATION

29

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

30

No.

Name

Notes

Type

LAC

Location Area Code

Int

CI

Cell ID

Int

10

NCC

Network Color Code

Int

11

BCC

BS Color Code

Int

12

FREQBAND

Frequency Band

Enumeration

13

SUBFREQBAND

Subcell Frequency Band


(GSM/DCS)

Enumeration

14

BCCHARFCN

Cell BCCH Absolute


Carrier No.

Int

15

CAFREQNUM

Frequency no. used by


cell

Int

16

CAARFCNLIST

Frequency list

String

17

MRETRANS

Max re-transmitted no.


of RACH access burst

Int

18

TXINTEGER

Transmit distribution
timeslot number

Int

19

CELLBARQUALIFY

Cell Barring Limit

Int

20

CELLBARACCESS

Cell Access Barring

Int

21

CALLREESTABLISH

Allow Call
Reestablishment

Int

22

EMERGENCYCALL

Allow Emergency Call

Int

23

ACCESSCONTROL

Access Level Control

String

24

IMSIADALLOWED

Allow IMSI Attach /


Detach

Int

25

CCCHCONF

Common Control
Channel Configuration

Enumeration

26

BSAGBLKRES

Number of access
granted block
reservation

Int

27

BSPAMFRAMS

Paging channel
multiplex frames

Int

28

T3212

Periodic position update


timer

Int

29

DTXUPLINKBCCH

Transmit UL
discontinuous BCCH
broadcast

Int

30

MSRADIOLKTMOUT

Link failure counter


maximum at Ms side

Int

31

T3122

Protection cycle of
access attempts

Int

32

MULBANDREPORT

Multiple band report

Int

33

NCCPERMITTED

Allowed Network Color


Code

String

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

34

SMSCBUSED

SMS broadcasted in cell

Enumeration

35

RESELHYSTERESIS

Reselect lagging level


value

Int

36

MSTXPWRMAXCCH

Maximum power level


of control channel

Int

37

ADDITIONRESELPI

Additional reselection
parameter indication
(that is, ACS)

Int

38

NECI

New established cause


indication

Int

39

RXLEVACCESSMIN

Minimum accessed
reception level
permitted

Int

40

CELLRESELPI

Reselect parameter
indication

Int

41

RESELOFFSET

Reselection Offset

Int

42

TEMPORARYOFFSET

Temporary offset

Int

43

PENALTYTIME

Penalty time

Int

44

POWEROFFSETIND

Power offset parameter


indication

Int

45

POWEROFFSET

Initial access power


modification for
DCS1800 MS

Int

46

ECSC

Early type ID
transmission control

Int

47

DRIND

Directional retry

Int

48

DTXDWLINK

Discontinuous DL
transmission

Int

49

QUEUEIND

Allow queue on
assignment / handover

String

50

PREEMPTIONIND2

Forcible release mark


on assignment /
handover

String

51

FORCEDHOIND

Forcible handover mark


on assignment /
handover

String

52

CANDIDATENUM

Candidate cell number


of handover message

Int

53

CIPHERMODE

Cipher mode supported


by the cell

Int

54

PREPROCESS

pre-processing

Int

55

FASTAVG

Measurement data
using fast average

Int

56

FACCHCALLIND

Allow FACCH call


establishment

Int

Confidential and Proprietary Information of ZTE CORPORATION

31

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

32

No.

Name

Notes

Type

57

RESOURCETHS

Minimum resource
threshold

Int

58

CCCHLOADINDPRD

CCCH load indication


period

Int

59

CCCHLOADINDTHS

Threshold to send
CCCH LOAD IND
message

String

60

INTERFAVGPRD

Interference average
period

Int

61

INTERFBOUNDARY

Interference boundary

String

62

NY1

Maximum repetition
number to send
physical message

Int

63

CONFAILCRITERIO
N

Radio link failure


criterion

Int

64

BSRADIOLKTMOUT

Inspect maximum of
radio link failure
counter at Bss side

Int

65

RXLEVTHS

Reception level
threshold

Int

66

RXQUALTHS

Reception quality
threshold

Int

67

RXLEVQUALPRD

Inspect period of radio


link failure

Int

68

OVERLOADPRD

Overload period

Int

69

T3105

Average bursts number


measured by RACH

Int

70

OVERLOADPRD

T200 timer

String

71

AVGSLOTS

Load common channel


identified within TRX
system

String

72

RACHBUSYTHS

BCCH exchange lock

Int

73

TAMAX

TA Maximum

Int

74

TAALLOWED

TA allowed value

Int

75

CHANSELECTPRIO

User channel rate


selection priority

Int

76

PSSUPPORT

Support GPRS

Enumeration

77

ADDRESPI2

Additional reselection
parameter indication

Int

78

EXC_ACC

Allow SoLSA special


access mobile

Int

79

LSA_OFFSET

LSA Offset

Int

80

PRIO_THR

Priority threshold

Int

81

LSA_ID

LSA ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

82

CELLSEQ

Unified ID of the cell in


this BSC system

Int

83

BCCHCHANIND

Timeslot indication of
common channel BCCH

String

84

PWRC

Power control indication

Int

85

CUROVERLEVEL

Current flow control


level

Int

86

LASTBARREDCLASS

Last barred MS

Int

87

DYNAHRENABLE

Support dynamic HR

Enumeration

88

USECELLDYNHRPAR
A

Enable cell dynamic HR


parameter

Int

89

HRTHS

Half-rate conversion
threshold

Int

90

SUBCELLUSED

Whether to use sub-cell

Enumeration

91

AMRFULLACS

Full-rate speech code


rate mode

Int

92

AMRHALFACS

Half-rate speech code


rate mode

Int

93

AMRTHRESHOLDS

AMR mode variation


threshold

String

94

AMRHYSTERESIS

AMR mode variation


lagging

String

95

ISAMRNSCB

AMR noise suppression

String

96

ISAMRICM

AMR encoding mode

String

97

AMRSTARTMODE

AMR original encoding


mode

String

98

TFOSUPPORT

Support TFO

Int

99

EMLPPTHS

eMLPP Channel
reservation proportion

Int

100

USECELLEMLPPTHS

Use cell eMLPP


reservation

Int

101

EMLPPBUSYNUM

number of eMLPP
reservation channels

Int

102

CSRSVRATE

CS channel reservation
proportion

Int

103

ADMSTATE

Administrative State

Int

104

NSEI

Network Service Entity


ID

Int

105

BVCI

BSSGP Virtual
Connection ID

Int

106

RAC

Routing Area Code

Int

107

UPUUNIT

User Plane Process


Board Unit Number

Int

Confidential and Proprietary Information of ZTE CORPORATION

33

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

34

No.

Name

Notes

Type

108

DSP

DSP ID

Int

109

T3168

Usage parameter at MS
side (T3168)

Int

110

T3192

Usage parameter at MS
side (T3192)

Int

111

DRXTIMEMAX

DRX mode holding time

Int

112

BSCVMAX

Maximum blocks
allowed at different
timeslot

Int

113

CTRACKTYPE

Packet control
acknowledgement type

Int

114

ACCESSTYPE

Access burst type

Int

115

PANDEC

N3102 decrease steplength

Int

116

PANINC

N3102 increase steplength

Int

117

PANMAX

N3102 Maximum

Int

118

PBCCHBLKS

Number of PBCCH
reservation blocks

Int

119

PAGBLKRES

Number of PAGCH
reservation blocks

Int

120

PRACHBLKS

Number of PRACH
reservation blocks

Int

121

TXINT

Packet access attempt


interval amplitude

Int

122

Packet access attempt


interval period

Int

123

MAXRETRANS

Maximum attempt
number

String

124

PERSISTLEV

Access persistence level

String

125

ACCCTRLCLASS

Access Control level

String

126

ALPHA

Power control
parameter

Int

127

T_AVG_W

Power control filtering


period in packet idle
mode

Int

128

T_AVG_T

Power control filtering


period in packet
transmission mode

Int

129

PB

PBCCH power
degression

Int

130

PCMEASCHAN

Power control
measurement channel

Int

131

PSI4SEND

PSI4 sending flag

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

132

N_AVG_I

Power control filter


constant

Int

133

RXLEVASMIN

GPRS MIN ACCESS


LEVEL

Int

134

MSTXMAXCCH

GPRS Max Initial Access


Level

Int

135

HCS_EXIST

HCS usage flag

Int

136

PRIOCLASS

HCS PRIORITY

Int

137

HCS_THR

HCS STRENGTH
THRESHOLD

Int

138

RESELOFF

Reselection Offset

Int

139

RESELHYS

GPRS cell reselection


lagging

Int

140

C31_HYST

Reselect lagging usage


flag

Int

141

C32_QUAL

Reselect Offset Usage


Rule

Int

142

RADACRETRY

Random access attempt


permitted

Int

143

T_RESEL

Reselect interval in this


cell

Int

144

RARESELHYS

Routing area
reselection lagging

Int

145

TEMPOFFSET

Reselect Temporary
Offset

Int

146

PENALTIME

Reselect Penalty Time

Int

147

SI3LOCATE

SI13 send location

Int

148

RACOLOR

Routing Area Color


Code

Int

149

MEAORDER

Measurement Report
Command

Int

150

CTRLORDER

Network control
command

Int

151

NCNODRXPER

NC non-DRX mode
holding time

Int

152

NCREPPERI

Packet idle mode

Int

153

NCRERPERT

Packet Transmission
Mode

Int

154

EXMEAORDER

Extend measurement
report command

Int

155

EXTREPTYPE

Extend measurement
report type

Int

156

EXTREPPER

Extend measurement
report period

Int

Confidential and Proprietary Information of ZTE CORPORATION

35

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

36

No.

Name

Notes

Type

157

SPGCSUPORT

Split Pg Cycle support


flag (CCCH)

Int

158

PRIACTHR

Packet access priority


threshold

Int

159

PSI1REPPER

PSI1 sending period

Int

160

PSISTATIND

PSI status support flag

Int

161

CSCHANSTHS

Idle CS channel
threshold

Int

162

SENDSPEED

System message sent


by high rate

String

163

EPAGEMODE

Support extension
paging

Int

164

LOADPER

PPCH load calculation


period

Int

165

OVLOADPER

PRACH overload report


period

Int

166

PCCCHINDTH

PCCCH overload
threshold

String

167

RLTIMEOUT

Link failure counter

Int

168

PRACHBUSYT

PRACH reception signal


level threshold

Int

169

MEAAVGSLOT

PRACH average
measurement bursts
number

Int

170

CHANGEMARK

Change mark

String

171

EGPRSPACKETCHRE
Q

Support EGPRS packet


channel request access
flow

Int

172

BEPPERIODUP

UL BEP filter average


period

Int

173

BEPPERIODDOWN

DL BEP filter average


period

Int

174

DTMSUPPORT

Support DTM

Int

175

GTTPLAPDMNUM

GTTP Lapdm Frame


maximum

Int

176

LINKQUAMEAMODE

Measurement report
mode of EGPRS MS

Int

177

IRSUPPORTUP

Support UL LA+IR
quality control mode

Int

178

PREEMPTIVETRANS

Privilege transmission
bit function

Int

179

USFGRANULARITY

Granularity selected
when allocating GPRS
MS UL block

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

180

EGPRSINITATTSELT

EGPRS MS Initial code

String

181

GPRSINITATTSELT

GPRS MS Initial code

String

182

INITATTACHEXCH

Whether GPRS/EGPRS
MS initial access code
can be dynamically
changed

Int

183

CCNACTIVE

Support CCN mode

Int

184

SISTATUSIND

Support system
message status flow

Int

185

EXT_UTBF

Support extension UL
TBF

Int

186

EXTDYNALLOCSUPP

Support extensible
dynamic allocation

Int

187

ULDELAYTIME

UL delay time (ms)

Int

188

DLDELAYTIME

DL delay time (ms)

Int

189

EXTULTBFTIME

Extensible UL timer
time (ms)

Int

190

GPRSDLRRBPINTER
VAL

RRBP interval block


number of DL GPRS
TBF

Int

191

EGPRSDLRRBPINTE
RVAL

RRBP interval block


number of DL EGPRS
TBF

Int

192

GPRSULACKINTERV
AL

UL response interval
block number of UL
GPRS TBF

Int

193

EGPRSULACKINTER
VAL

UL response interval
block number per
channel of UL EGPRS
TBF

Int

194

ULMEASUREPERIOD

UL measurement report
processing period (ms)

Int

195

PHYCELL

Physical cell

Int

196

HYBRIDOCCUSUPP

Support user seize


extrinsic preferred
channel

Int

197

ALLOWPSMOVE

Support user migrate to


extrinsic preferred
channel

Int

198

ALLOWCSMOVE

Support CS user
migration

Int

199

SFPREFERBUSYTHS

Homogeneous seizure
threshold

Int

200

OPPREFERBUSYTHS

Extrinsic seizure
threshold

Int

Confidential and Proprietary Information of ZTE CORPORATION

37

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

0~40

1-1

1-1

1~65535

1-1

0~65535

1-1

10

0~7

1-1

11

0~7

1-1

12

1-1

13

1-1

14

0~1023

1-1

15

0~64

1-1

16

0~400

1-1

17

0~3

1-1

18

0~15

1-1

19

0~1

1-1

20

0~1

1-1

21

0~1

1-1

22

0~1

1-1

23

0~10000

1-1

24

0~1

1-1

25

38

Default

Instance
Count

No.

1-1

26

0~7

1-1

27

2~9

1-1

28

0~255

1-1

29

0~2

1-1

30

0~15

1-1

31

0~255

1-1

32

0~3

1-1

33

0~16

1-1

34

0~1

1-1

35

0~7

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Default

Instance
Count

No.

Range

36

0~31

1-1

37

0~1

1-1

38

0~1

1-1

39

0~63

1-1

40

0~1

1-1

41

0~63

1-1

42

0~7

1-1

43

0~31

1-1

44

0~1

1-1

45

0~3

1-1

46

0~1

1-1

47

0~1

1-1

48

0~1

1-1

49

0~10000

1-1

50

0~10000

1-1

51

0~10000

1-1

52

1~16

1-1

53

1~255

1-1

54

0~4

1-1

55

0~1

1-1

56

0~10000

1-1

57

0~100

1-1

58

1~255

1-1

59

0~5050

1-1

60

1~31

1-1

61

0~10000

1-1

62

5~35

1-1

63

1~2

1-1

64

0~15

1-1

65

0~63

1-1

66

0~7

1-1

67

1~63

1-1

68

1~63

1-1

69

0~100

1-1

70

1~255

1-1

71

0~100

1-1

Confidential and Proprietary Information of ZTE CORPORATION

39

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Range

72

0~63

1-1

73

0~219

1-1

74

0~219

1-1

75

0~10000

1-1

76

1-1

77

0~1

1-1

78

0~1

1-1

79

0~7

1-1

80

0~7

1-1

81

0~16777215

1-1

82

0~10000

1-1

83

0~10000

1-1

84

0~1

1-1

85

0~10000

1-1

86

0~10000

1-1

87

1-1

88

0~1

1-1

89

1~100

1-1

90

40

Default

Instance
Count

No.

1-1

91

1~255

1-1

92

1~31

1-1

93

0~10000

1-1

94

0~10000

1-1

95

0~10000

1-1

96

0~10000

1-1

97

0~10000

1-1

98

0~1

1-1

99

0~100

1-1

100

0~1

1-1

101

0~10000

1-1

102

1~100

1-1

103

0~1

1-1

104

0~65535

1-1

105

0~65535

1-1

106

0~255

1-1

107

0~2000

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Default

Instance
Count

No.

Range

108

0~71

1-1

109

0~7

1-1

110

0~7

1-1

111

0~7

1-1

112

0~15

1-1

113

0~1

1-1

114

0~1

1-1

115

0~7

1-1

116

0~7

1-1

117

0~7

1-1

118

0~3

1-1

119

0~15

1-1

120

0~15

1-1

121

0~15

1-1

122

0~9

1-1

123

0~10000

1-1

124

0~10000

1-1

125

0~10000

1-1

126

0~15

1-1

127

0~31

1-1

128

0~31

1-1

129

0~15

1-1

130

0~1

1-1

131

0~1

1-1

132

0~15

1-1

133

0~63

1-1

134

0~31

1-1

135

0~1

1-1

136

0~7

1-1

137

0~63

1-1

138

0~31

1-1

139

0~7

1-1

140

0~1

1-1

141

0~1

1-1

142

0~1

1-1

143

0~7

1-1

Confidential and Proprietary Information of ZTE CORPORATION

41

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

42

Range

144

0~7

1-1

145

0~7

1-1

146

0~31

1-1

147

0~1

1-1

148

0~7

1-1

149

0~1

1-1

150

0~3

1-1

151

0~7

1-1

152

0~7

1-1

153

0~7

1-1

154

0~3

1-1

155

0~3

1-1

156

0~7

1-1

157

0~1

1-1

158

0~7

1-1

159

0~15

1-1

160

0~1

1-1

161

0~255

1-1

162

0~10000

1-1

163

0~1

1-1

164

0~16

1-1

165

0~255

1-1

166

0~10000

1-1

167

0~100

1-1

168

0~63

1-1

169

0~100

1-1

170

0~10000

1-1

171

0~1

1-1

172

0~15

1-1

173

0~10

1-1

174

0~1

1-1

175

0~7

1-1

176

0~3

1-1

177

0~1

1-1

178

0~1

1-1

179

0~1

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Default

Instance
Count

No.

Chapter 2 - Single Command Processing

Output
Parameters

Enumeration
Description

Default

Instance
Count

No.

Range

180

0~10000

1-1

181

0~10000

1-1

182

0~3

1-1

183

0~1

1-1

184

0~1

1-1

185

0~1

1-1

186

0~1

1-1

187

0~4000

1-1

188

500~4000

1-1

189

0~3000

1-1

190

3~20

1-1

191

6~60

1-1

192

3~20

1-1

193

3~20

1-1

194

400~2000

1-1

195

0~198

1-1

196

0~1

1-1

197

0~1

1-1

198

0~1

1-1

199

0~100

1-1

200

0~100

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Common Control Channel configuration information is as follows:

Macro Name

Meaning

CCCHCONF_0

One basic physical channel used by CCCH,


not used with SDCCH

CCCHCONF_1

One basic physical channel used by CCCH,


used with SDCCH

CCCHCONF_2

Two basic physical channels used by

Confidential and Proprietary Information of ZTE CORPORATION

43

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Macro Name

Meaning
CCCH, not used with SDCCH

CCCHCONF_4

Three basic physical channels used by


CCCH, note used with SDCCH

CCCHCONF_6

Four basic physical channels used by


CCCH, not used with SDCCH

Cell band information is as follows:


Macro Name

Meaning

FREQBAND_0

GSM900

FREQBAND_1

EXT900

FREQBAND_2

DCS1800

FREQBAND_7

GSM850

FREQBAND_4

PCS1900

BOOLEAN information is as follows:


Macro Name

Meaning

BOOLEAN_NO

No

BOOLEAN_YES

Yes

Cell type information is as follows:


Macro Name

Meaning

CELLTYPE_0

Umbrella Cell

CELLTYPE_1

Macro Cell

CELLTYPE_2

Micro Cell

CELLTYPE_3

Pico Cell

CELLTYPE_4

Extended Cell

The information to support GPRS is as follows:

Example

44

Macro Name

Meaning

PSSUPPORT_0

Doesnt Support GPRS

PSSUPPORT_1

Support GPRS

PSSUPPORT_2

Support EDGE

SET
BTS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
USERLABEL="0",CELLTYPE= ,LAC=1,CI=0,NCC=0,BCC=0,FREQ
BAND= ,SUBFREQBAND= ,BCCHARFCN=0,CAFREQNUM=0,CAAR
FCNLIST="0",MRETRANS=0,TXINTEGER=0,CELLBARQUALIFY=0,
CELLBARACCESS=0,CALLREESTABLISH=0,EMERGENCYCALL=0,
ACCESSCONTROL="0",IMSIADALLOWED=0,CCCHCONF= ,BSAG
BLKRES=0,BSPAMFRAMS=2,T3212=0,DTXUPLINKBCCH=0,MSR
ADIOLKTMOUT=0,T3122=0,MULBANDREPORT=0,NCCPERMITTE

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

D="0",SMSCBUSED=0,RESELHYSTERESIS=0,MSTXPWRMAXCCH
=0,ADDITIONRESELPI=0,NECI=0,RXLEVACCESSMIN=0,CELLRE
SELPI=0,RESELOFFSET=0,TEMPORARYOFFSET=0,PENALTYTIME
=0,POWEROFFSETIND=0,POWEROFFSET=0,ECSC=0,DRIND=0,
DTXDWLINK=0,QUEUEIND="0",PREEMPTIONIND="0",FORCEDH
OIND="0",CANDIDATENUM=1,CIPHERMODE=1,PREPROCESS=0,
FASTAVG=0,FACCHCALLIND=0,RESOURCETHS=0,CCCHLOADIN
DPRD=1,CCCHLOADINDTHS="0",INTERFAVGPRD=1,INTERFBOU
NDARY="0",NY1=5,CONFAILCRITERION=1,BSRADIOLKTMOUT=
0,RXLEVTHS=0,RXQUALTHS=0,T200="1",RXLEVQUALPRD=1,T3
105="0",OVERLOADPRD=1,BCCHTRXSEQ=0,AVGSLOTS=0,CAN
BCCHEXCH=0,RACHBUSYTHS=0,EXCHLOCK=0,HAVEEXCH=0,EX
CHTRXID=1,CANSDCCHDY
N=0,TAMAX=0,TAALLOWED=0,CHANSELECTPRIO=0,PSSUPPOR
T= ,ADDRESPI2=0,EXC_ACC=0,LSA_OFFSET=0,PRIO_THR=0,L
SA_ID=0,CELLSEQ=0,BCCHCHANIND="0",PWRC=0,CUROVERLE
VEL=0,LASTBARREDCLASS=0,DYNAHRENABLE= ,USECELLDYNH
RPARA=0,HRTHS=1,SUBCELLUSED= ,AMRFULLACS=1,AMRHALF
ACS=1,AMRTHRESHOLDS="0",AMRHYSTERESIS="0",ISAMRNSC
B="0",ISAMRICM="0",AMRSTARTMODE="0",TFOSUPPORT=0,EM
LPPTHS=0,USECELLEMLPPTHS=0,EMLPPBUSYNUM=0,CSRSVRAT
E=1,ADMSTATE=0,WORK=0,NSEI=0,BVCI=0,RAC=0,UPUUNIT=
0,DSP=0,T3168=0,T3192=0,DRXTIMEMAX=0,BSCVMAX=0,CTR
ACKTYPE=0,ACCESSTYPE=0,PANDEC=0,PANINC=0,PANMAX=0,
PBCCHBLKS=0,PAGBLKRES=0,PRACHBLKS=0,TXINT=0,S=0,MA
XRETRANS="0",PERSISTLEV="0",ACCCTRLCLASS="0",ALPHA=0
,T_AVG_W=0,T_AVG_T=0,PB=0,PCMEASCHAN=0,PSI4SEND=0,
N_AVG_I=0,RXLEVASMIN=0,MSTXMAXCCH=0,HCS_EXIST=0,PR
IOCLASS=0,HCS_THR=0,RESELOFF=0,RESELHYS=0,C31_HYST
=0,C32_QUAL=0,RADACRETRY=0,T_RESEL=0,RARESELHYS=0,
TEMPOFFSET=0,PENALTIME=0,SI3LOCATE=0,RACOLOR=0,MEA
ORDER=0,CTRLORDER=0,NCNODRXPER=0,NCREPPERI=0,NCRE
RPERT=0,EXMEAORDER=0,EXTREPTYPE=0,EXTREPPER=0,SPGC
SUPORT=0,PRIACTHR=0,PS
I1REPPER=0,PSISTATIND=0,CSCHANSTHS=0,SENDSPEED="0",
EPAGEMODE=0,LOADPER=0,OVLOADPER=0,PCCCHINDTH="0",
RLTIMEOUT=0,PRACHBUSYT=0,MEAAVGSLOT=0,CHANGEMARK
="0",EGPRSPACKETCHREQ=0,BEPPERIODUP=0,BEPPERIODDOW
N=0,DTMSUPPORT=0,GTTPLAPDMNUM=0,LINKQUAMEAMODE=0
,IRSUPPORTUP=0,PREEMPTIVETRANS=0,USFGRANULARITY=0,E
GPRSINITATTSELT="0",GPRSINITATTSELT="0",INITATTACHEXC
H=0,CCNACTIVE=0,SISTATUSIND=0,EXT_UTBF=0,ISSYNCUPU=
0,EXTDYNALLOCSUPP=0,ULDELAYTIME=0,DLDELAYTIME=500,E
XTULTBFTIME=0,GPRSDLRRBPINTERVAL=3,EGPRSDLRRBPINTE
RVAL=6,GPRSULACKINTERVAL=3,EGPRSULACKINTERVAL=3,UL
MEASUREPERIOD=400,STATUS=0,BCCHBAIND=0,PHYCELL=0,H
YBRIDOCCUSUPP=0,ALLOWPSMOVE=0,ALLOWCSMOVE=0,SFPR
EFERBUSYTHS=0,OPPREFERBUSYTHS=0,STARTTRXPOWEROFF=
;

Confidential and Proprietary Information of ZTE CORPORATION

45

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Configure cell object


Delete transceiver
Prompt

DEL TRX

Format

DEL
TRX:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,TR
XID=<TRXID>];

Input
Parameters

Output
Parameters

Example

46

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

TRXID

Transceiver ID

Int

No.

Range

Default

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~54

1-1

Instance
Count

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL
TRX:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
TRXID=1;

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Display transceiver
Prompt

SHW TRX

Format

SHW
TRX:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,TR
XID=<TRXID>][,PARAMS=<PARAMS>];

Input
Parameters

Output
Parameters

Example

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

TRXID

Transceiver ID

Int

PARAMS

Parameter List

String

Default

Instance
Count

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~54

1-1

0~1000

""

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

29

INFO

Complex

Query Result

1-10000

SHW
TRX:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
TRXID=1,PARAMS=" ";

Confidential and Proprietary Information of ZTE CORPORATION

47

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Modify transceiver
Prompt

SET TRX

Format

SET
TRX:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,TR
XID=<TRXID>][,USERLABEL=<USERLABEL>][,RACKNO=<RAC
KNO>][,SHELFNO=<SHELFNO>][,PANELNO=<PANELNO>][,RRU
ID=<RRUID>][,TRXTYPE=<TRXTYPE>][,PWRREDUCTION=<PW
RREDUCTION>][,CAFREQNUM=<CAFREQNUM>][,CAARFCNLIST
=<CAARFCNLIST>][,BCCHMARK=<BCCHMARK>][,TRXPRIORITY
=<TRXPRIORITY>][,SUBCELLID=<SUBCELLID>][,PORTNO=<P
ORTNO>][,BIPBUNIT=<BIPBUNIT>][,DSP=<DSP>][,DSPMARKS
EQ=<DSPMARKSEQ>];

Input
Parameters

48

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

TRXID

Transceiver ID

Int

USERLABEL

User Label

String

RACKNO

Rack No.

Int

SHELFNO

Layer No.

Int

10

PANELNO

Panel no.

Int

11

RRUID

RRU ID

Int

12

TRXTYPE

Transceiver type

Int

13

PWRREDUCTION

Static power level


of cell Trx

Enumeratio
n

14

CAFREQNUM

Number of
corresponding
frequency

Int

15

CAARFCNLIST

Frequency list of
corresponding
carrier

String

16

BCCHMARK

BCCH carrier

Int

17

TRXPRIORITY

Allocation priority
for same type of
carrier

Int

18

SUBCELLID

Subcell ID

Int

19

PORTNO

Port no.

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

20

BIPBUNIT

RTPB unit No.

Int

21

DSP

RTPB DSP No.

Int

22

DSPMARKSEQ

Mark sequence on
DSP for carrier

Int

Default

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~54

1-1

0~40

1-1

1~16

1-1

0~6

1-1

10

1~24

1-1

11

0~48

12

0~1

1-1
1-1

PWRREDUCTION
_0

13

Output
Parameters

Instance
Count

No.

1-1

14

0~64

1-1

15

0~400

1-1

16

0~1

17

1~5

1-1

18

1~2

1-1

19

0~65535

1-1

20

0~2000

1-1

21

0~71

1-1

22

0~15

1-1

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Confidential and Proprietary Information of ZTE CORPORATION

49

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Enumeration
Description

Static power level information is as follows:

Macro Name

Meaning

PWRREDUCTION_0

Max output power

PWRREDUCTION_1

Max output power C2dB

PWRREDUCTION_2

Max output power C4dB

PWRREDUCTION_3

Max output power C6dB

PWRREDUCTION_4

Max output power C8dB

PWRREDUCTION_5

Max output power C10dB

PWRREDUCTION_6

Max output power C12dB

PWRREDUCTION_253

Max output power +1.5dB

PWRREDUCTION_254

Max output power +1dB

PWRREDUCTION_255

Max output power +0.5dB

Example

SET
TRX:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
TRXID=1,USERLABEL="0",RACKNO=1,SHELFNO=0,PANELNO=1,
RRUID=0,TRXTYPE=0,PWRREDUCTION=PWRREDUCTION_0,CAF
REQNUM=0,CAARFCNLIST="0",BCCHMARK=0,TRXPRIORITY=1,
SUBCELLID=1,PORTNO=0,BIPBUNIT=0,DSP=0,DSPMARKSEQ=0;

Remarks

If carrier is changed to BCCH carrier, frequency list and number


is modified correspondingly, frequency list will be consistent with
cell BCCH frequency, and the frequency number is 1.

Display Channel
Prompt

SHW CHAN

Format

SHW
CHAN:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>]
[,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,T
RXID=<TRXID>][,TSID=<TSID>][,PARAMS=<PARAMS>];

Input
Parameters

50

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

TRXID

Transceiver ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Example

No.

Name

Notes

Type

TSID

Int

PARAMS

Parameter List

String

Default

Instance
Count

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~54

1-1

0~7

1-1

0~1000

""

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

20

INFO

Complex

Query Result

1-10000

SHW
CHAN:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,TRXID=1,TSID=0,PARAMS=" ";

Modify Channel
Prompt

SET CHAN

Format

SET
CHAN:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>]
[,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,T
RXID=<TRXID>][,TSID=<TSID>][,USERLABEL=<USERLABEL>]
[,FHSID=<FHSID>][,ARFCN=<ARFCN>][,TSCHANNELCOMB=<T
SCHANNELCOMB>][,MAIO=<MAIO>][,TSC=<TSC>][,TYPEUSED
=<TYPEUSED>][,CHANGEABLE=<CHANGEABLE>][,PREFERPSSE
RVICE=<PREFERPSSERVICE>];

Confidential and Proprietary Information of ZTE CORPORATION

51

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Input
Parameters

52

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

TRXID

Transceiver ID

Int

TSID

Timeslot ID

Int

USERLABEL

User Label

String

FHSID

Corresponding
FhsID system ID

Int

10

ARFCN

Timeslot frequency
corresponding to
TRX

Int

11

TSCHANNELCOMB

Timeslot channel
combination type

Enumeration

12

MAIO

Mobile allocation
index offset on
hopping

Int

13

TSC

Training serial code

Int

14

TYPEUSED

Use type of channel

Enumeration

15

CHANGEABLE

Dynamic timeslot or
not

Int

16

PREFERPSSERVICE

Channel packet
service priority
property

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~54

1-1

0~7

1-1

0~40

1-1

0~255

1-1

10

0~65535

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Default

Instance
Count

Chapter 2 - Single Command Processing

No.

Range

Default

11

Output
Parameters

Enumeration
Description

Instance
Count
1-1

12

0~63

1-1

13

0~7

1-1

14

0~4

1-1

15

0~1

1-1

16

0~255

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Timeslot channel combination types are explained as follows:

Macro Name

Meaning

TSCHANNELCOMB_1

TCH/H(0,1)+FACCH/H(0,1)+SACCH/TH(0,1)

TSCHANNELCOMB_2

TCH/H(0,0)+FACCH/H(0,1)+SACCH/TH(0,1)+TCH/H(0,1)

TSCHANNELCOMB_3

SDCCH/8+SACCH/C8

TSCHANNELCOMB_4

FCCH+SCH+BCCH+CCCH

TSCHANNELCOMB_5

BCCH+SDCCH/4

TSCHANNELCOMB_6

BCCH+CCCH

TSCHANNELCOMB_7

BCCH+SDCCH/4+CBCH

TSCHANNELCOMB_8

SDCCH + CBCH

TSCHANNELCOMB_9

TCH/F + FACCH/F + SACCH/M

TSCHANNELCOMB_10

TCH/F + SACCH/M

TSCHANNELCOMB_11

TCH/FD + SACCH/MD

TSCHANNELCOMB_12

PBCCH+PCCCH+PDTCH+PACCH+PTCCH

TSCHANNELCOMB_13

PCCCH+PDTCH+PACCH+PTCCH

TSCHANNELCOMB_14

PDTCH+PACCH+PTCCH

TSCHANNELCOMB_0

TCH/F

Note: Currently, three channel types are not supported,


that is, TCH/F + FACCH/F+SACCH/M, TCH/F + SACCH/M,
TCH/FD + SACCH/MD.

Confidential and Proprietary Information of ZTE CORPORATION

53

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Example

SET
CHAN:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,TRXID=1,TSID=0,USERLABEL="0",TSCHANNELCOMB= ,MAIO
=0,TSC=0,DYNSTATE=0,CHANGEABLE=0,PREFERPSSERVICE=0;

Create Hopping System


Prompt

ADD FHS

Format

ADD
FHS:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,BSC
ID=<BSCID>,SITEID=<SITEID>,BTSID=<BTSID>,FHSID=<FH
SID>[,USERLABEL=<USERLABEL>],FREQHOPMODE=<FREQHOP
MODE>,HSN=<HSN>,MAFREQNUM=<MAFREQNUM>,MAARFCNL
IST=<MAARFCNLIST>;

Input
Parameters

54

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

FHSID

Corresponding
FhsID system ID

Int

USERLABEL

User Label

String

FREQHOPMODE

Frequency
hopping mode

Enumeratio
n

HSN

Hopping serial
number

Int

10

MAFREQNUM

Frequency
number

Int

11

MAARFCNLIST

MAFrequency list

String

No.

Range

Default

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~255

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Instance
Count

Chapter 2 - Single Command Processing

No.

Range

Default

Instance
Count

0~40

""

1-1

FREQHOPMODE_
2

1-1

Output
Parameters

Enumeration
Description

0~63

1-1

10

1~64

1-1

11

1~512

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Hopping mode information is shown as follows:

Macro Name

Meaning

FREQHOPMODE_1

Baseband hopping

FREQHOPMODE_2

RF hopping

Example

ADD
FHS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
FHSID=1,USERLABEL="",FREQHOPMODE=FREQHOPMODE_2,HS
N=0,MAFREQNUM=1,MAARFCNLIST="1";

Remarks

Hopping number must be consistent with those in hopping


frequency list. Also, the frequency must be within the cell
frequency range.

Delete Hopping System


Prompt

DEL FHS

Format

DEL
FHS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,FH
SID=<FHSID>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

55

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

No.

Name

Notes

Type

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

FHSID

Corresponding
FhsID system ID

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~255

1-1

Default

Instance
Count

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL
FHS:SUBNETID=0,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
FHSID=1;

Display Hopping System


Prompt

SHW FHS

Format

SHW
FHS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,FH
SID=<FHSID>][,PARAMS=<PARAMS>];

Input
Parameters

56

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Example

No.

Name

Notes

Type

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

FHSID

Corresponding
FhsID system ID

Int

PARAMS

Parameter List

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~255

1-1

0~1000

Default

""

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

13

INFO

Complex

Query Result

1-10000

SHW
FHS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
FHSID=1,PARAMS=" ";

Modify Hopping System


Prompt

SET FHS

Format

SET
FHS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,FH
SID=<FHSID>][,USERLABEL=<USERLABEL>][,HSN=<HSN>][,
MAFREQNUM=<MAFREQNUM>][,MAARFCNLIST=<MAARFCNLIST
>];

Input
Parameters

Description of input parameters is as follows:

Confidential and Proprietary Information of ZTE CORPORATION

57

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

58

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

FHSID

Corresponding
FhsID system ID

Int

USERLABEL

User Label

String

HSN

Hopping serial
number

Int

MAFREQNUM

Frequency
number

Int

10

MAARFCNLIST

MA Frequency list

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~255

1-1

0~40

1-1

0~63

1-1

1~64

1-1

10

1~512

1-1

Default

Instance
Count

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

SET
FHS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
FHSID=1,USERLABEL="0",HSN=0,MAFREQNUM=1,MAARFCNLIS
T="1";

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Display Power Control


Prompt

SHW POC

Format

SHW
POC:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,SU
BCELLID=<SUBCELLID>][,PARAMS=<PARAMS>];

Input
Parameters

Output
Parameters

Example

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

SUBCELLID

Subcell ID

Int

PARAMS

Parameter List

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~2

1-1

0~1000

Default

""

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

57

INFO

Complex

Query Result

1-10000

SHW
POC:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
SUBCELLID=1,PARAMS=" ";

Confidential and Proprietary Information of ZTE CORPORATION

59

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Modify Power Control


Prompt

SET POC

Format

SET
POC:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,SU
BCELLID=<SUBCELLID>][,USERLABEL=<USERLABEL>][,PCULL
EVWINDOW=<PCULLEVWINDOW>][,PCULLEVWEIGHT=<PCULL
EVWEIGHT>][,PCDLLEVWINDOW=<PCDLLEVWINDOW>][,PCDL
LEVWEIGHT=<PCDLLEVWEIGHT>][,PCULQUALWINDOW=<PCUL
QUALWINDOW>][,PCULQUALWEIGHT=<PCULQUALWEIGHT>][,
PCDLQUALWINDOW=<PCDLQUALWINDOW>][,PCDLQUALWEIGH
T=<PCDLQUALWEIGHT>][,PWRCONTROLUL=<PWRCONTROLUL
>][,PWRCONTROLDL=<PWRCONTROLDL>][,PWRINCSTEP=<PW
RINCSTEP>][,PWRREDSTEP=<PWRREDSTEP>][,PCULINCLLEVT
HS=<PCULINCLLEVTHS>][,PCULREDLEVTHS=<PCULREDLEVTH
S>][,PCULINCLQUALTHS=<PCULINCLQUALTHS>][,PCULREDQU
ALTHS=<PCULREDQUALTHS>][,PCDLINCLLEVTHS=<PCDLINCLL
EVTHS>][,PCDLREDLEVTHS=<PCDLREDLEVTHS>][,PCDLINCLQ
UALTHS=<PCDLINCLQUALTHS>][,PCDLREDQUALTHS=<PCDLRE
DQUALTHS>][,PCULINCLLEVP=<PCULINCLLEVP>][,PCULINCLLE
VN=<PCULINCLLEVN>][,PCDLINCLLEVP=<PCDLINCLLEVP>][,PC
DLINCLLEVN=<PCDLINCLLEVN>][,PCULREDLEVP=<PCULREDLE
VP>][,PCULREDLEVN=<PCULREDLEVN>][,PCDLREDLEVP=<PCD
LREDLEVP>][,PCDLREDLEVN=<PCDLREDLEVN>][,PCULINCLQUA
LP=<PCULINCLQUALP>][,PCULINCLQUALN=<PCULINCLQUALN>
][,PCDLINCLQUALP=<PCDLINCLQUALP>][,PCDLINCLQUALN=<P
CDLINCLQUALN>][,PCULREDQUALP=<PCULREDQUALP>][,PCUL
REDQUALN=<PCULREDQUALN>][,PCDLREDQUALP=<PCDLREDQ
UALP>][,PCDLREDQUALN=<PCDLREDQUALN>][,MSTXPWRMAX
=<MSTXPWRMAX>][,MSTXPWRMIN=<MSTXPWRMIN>][,BSTXP
WRMIN=<BSTXPWRMIN>][,RAPIDPCIND=<RAPIDPCIND>][,PC
MININTERVAL=<PCMININTERVAL>][,PWRDECRLIMIT=<PWRDE
CRLIMIT>][,PWRCTRLREPORTPRD=<PWRCTRLREPORTPRD>][,U
LPWCTRL=<ULPWCTRL>][,DLPWCTRL=<DLPWCTRL>][,SS_BTS
=<SS_BTS>][,PWCTRLMODE=<PWCTRLMODE>][,PWCTRLLEV=
<PWCTRLLEV>][,P0=<P0>];

Input
Parameters

60

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

SUBCELLID

Subcell ID

Int

USERLABEL

User Label

String

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

PCULLEVWINDOW

Sample count used for


UL strength
measurement average

Int

PCULLEVWEIGHT

Weight average of UL
strength

Int

10

PCDLLEVWINDOW

Sample count used for


DL strength
measurement average

Int

11

PCDLLEVWEIGHT

Weight average of DL
strength

Int

12

PCULQUALWINDOW

Sample count used for


UL quality
measurement average

Int

13

PCULQUALWEIGHT

Weight average of UL
quality

Int

14

PCDLQUALWINDOW

Sample count used for


DL quality
measurement average

Int

15

PCDLQUALWEIGHT

Weight average of DL
quality

Int

16

PWRCONTROLUL

UL Power Control

Int

17

PWRCONTROLDL

DL Power Control

Int

18

PWRINCSTEP

Power increase step (2,


4, 6dB)

Int

19

PWRREDSTEP

Power decrease step


(2, 4dB)

Int

20

PCULINCLLEVTHS

UL RxLev threshold for


power increase

Int

21

PCULREDLEVTHS

UL RxLev threshold for


power decrease

Int

22

PCULINCLQUALTHS

UL RxQual threshold
for power increase

Int

23

PCULREDQUALTHS

UL RxQual threshold
for power decrease

Int

24

PCDLINCLLEVTHS

DL RxLev threshold for


power increase

Int

25

PCDLREDLEVTHS

DL RxLev threshold for


power decrease

Int

26

PCDLINCLQUALTHS

DL RxQual threshold
for power increase

Int

27

PCDLREDQUALTHS

DL RxQual threshold
for power decrease

Int

28

PCULINCLLEVP

UL strength value-p for


power increase

Int

29

PCULINCLLEVN

UL strength value-n for

Int

Confidential and Proprietary Information of ZTE CORPORATION

61

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

No.

Name

Notes

Type

power increase

62

30

PCDLINCLLEVP

DL strength value-p for


power increase

Int

31

PCDLINCLLEVN

DL strength value-n for


power increase

Int

32

PCULREDLEVP

UL strength value-p for


power decrease

Int

33

PCULREDLEVN

UL strength value-n for


power decrease

Int

34

PCDLREDLEVP

DL strength value-p for


power decrease

Int

35

PCDLREDLEVN

DL strength value-n for


power decrease

Int

36

PCULINCLQUALP

UL quality value-p for


power increase

Int

37

PCULINCLQUALN

UL quality value-n for


power increase

Int

38

PCDLINCLQUALP

DL quality value-p for


power increase

Int

39

PCDLINCLQUALN

DL quality value-n for


power increase

Int

40

PCULREDQUALP

UL quality value-p for


power decrease

Int

41

PCULREDQUALN

UL quality value-n for


power decrease

Int

42

PCDLREDQUALP

DL quality value-p for


power decrease

Int

43

PCDLREDQUALN

DL quality value-n for


power decrease

Int

44

MSTXPWRMAX

MS max power level

Int

45

MSTXPWRMIN

MS min power level

Int

46

BSTXPWRMIN

BS min power level

Int

47

RAPIDPCIND

Rapid power control

Int

48

PCMININTERVAL

Min interval of power


control

Int

49

PWRDECRLIMIT

Power decrease limit

String

50

PWRCTRLREPORTPR
D

Performance
measurement report
period (51 multiframe)

Int

51

ULPWCTRL

UL Power Control Policy

Int

52

DLPWCTRL

DL Power Control Policy

Int

53

SS_BTS

MS signal strength to
be received

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

54

PWCTRLMODE

Power control mode


used in DL direction

Int

55

PWCTRLLEV

Power control level

Int

56

P0

Power decrease
quantity of PDCH
relative to BCCH on
mode A

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~2

1-1

0~40

1-1

1~31

1-1

1~3

1-1

10

1~31

1-1

11

1~3

1-1

12

1~31

1-1

13

1~3

1-1

14

1~31

1-1

15

1~3

1-1

16

0~1

1-1

17

0~1

1-1

18

0~2

1-1

19

0~1

1-1

20

0~63

1-1

21

0~63

1-1

22

0~7

1-1

23

0~7

1-1

24

0~63

1-1

25

0~63

1-1

26

0~7

1-1

27

0~7

1-1

28

1~31

1-1

Default

Instance
Count

Confidential and Proprietary Information of ZTE CORPORATION

63

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

64

Default

Instance
Count

No.

Range

29

1~31

1-1

30

1~31

1-1

31

1~31

1-1

32

1~31

1-1

33

1~31

1-1

34

1~31

1-1

35

1~31

1-1

36

1~31

1-1

37

1~31

1-1

38

1~31

1-1

39

1~31

1-1

40

1~31

1-1

41

1~31

1-1

42

1~31

1-1

43

1~31

1-1

44

0~31

1-1

45

0~31

1-1

46

0~15

1-1

47

0~1

1-1

48

1~255

1-1

49

0~10000

1-1

50

1~254

1-1

51

0~3

1-1

52

0~3

1-1

53

0~63

1-1

54

0~1

1-1

55

0~31

1-1

56

0~15

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Example

SET
POC:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
SUBCELLID=1,USERLABEL="0",PCULLEVWINDOW=1,PCULLEVW
EIGHT=1,PCDLLEVWINDOW=1,PCDLLEVWEIGHT=1,PCULQUALW
INDOW=1,PCULQUALWEIGHT=1,PCDLQUALWINDOW=1,PCDLQ
UALWEIGHT=1,PWRCONTROLUL=0,PWRCONTROLDL=0,PWRINC
STEP=0,PWRREDSTEP=0,PCULINCLLEVTHS=0,PCULREDLEVTHS
=0,PCULINCLQUALTHS=0,PCULREDQUALTHS=0,PCDLINCLLEVT
HS=0,PCDLREDLEVTHS=0,PCDLINCLQUALTHS=0,PCDLREDQUAL
THS=0,PCULINCLLEVP=1,PCULINCLLEVN=1,PCDLINCLLEVP=1,P
CDLINCLLEVN=1,PCULREDLEVP=1,PCULREDLEVN=1,PCDLREDL
EVP=1,PCDLREDLEVN=1,PCULINCLQUALP=1,PCULINCLQUALN=
1,PCDLINCLQUALP=1,PCDLINCLQUALN=1,PCULREDQUALP=1,PC
ULREDQUALN=1,PCDLREDQUALP=1,PCDLREDQUALN=1,MSTXP
WRMAX=0,MSTXPWRMIN=0,BSTXPWRMIN=0,RAPIDPCIND=0,P
CMININTERVAL=1,PWRDECRLIMIT="0",PWRCTRLREPORTPRD=1
,ULPWCTRL=0,DLPWCTRL=0,SS_BTS=0,PWCTRLMODE=0,PWCT
RLLEV=0,P0=0;

Display Handover Control


Prompt

SHW HOC

Format

SHW
HOC:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][
,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,H
OCID=<HOCID>][,PARAMS=<PARAMS>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

HOCID

HOC ID

Int

PARAMS

Parameter List

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

Default

Instance
Count

Confidential and Proprietary Information of ZTE CORPORATION

65

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

No.

Range

1~10000

0~1000

Default

Instance
Count
1-1

""

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

87

INFO

Complex

Query Result

1-10000

SHW
HOC:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1
,HOCID=1,PARAMS=" ";

Modify Handover Control

66

Prompt

SET HOC

Format

SET
HOC:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][
,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,H
OCID=<HOCID>][,USERLABEL=<USERLABEL>][,HOULLEVWIN
DOW=<HOULLEVWINDOW>][,HOULLEVWEIGHT=<HOULLEVWE
IGHT>][,HODLLEVWINDOW=<HODLLEVWINDOW>][,HODLLEV
WEIGHT=<HODLLEVWEIGHT>][,HOULQUALWINDOW=<HOULQ
UALWINDOW>][,HOULQUALWEIGHT=<HOULQUALWEIGHT>][,H
ODLQUALWINDOW=<HODLQUALWINDOW>][,HODLQUALWEIGH
T=<HODLQUALWEIGHT>][,DISTANCEWINDOW=<DISTANCEWI
NDOW>][,NCELLWINDOW=<NCELLWINDOW>][,ZEROALLOWED
=<ZEROALLOWED>][,HOMININTERVAL=<HOMININTERVAL>][,
DISTANCETHS=<DISTANCETHS>][,HOULLEVTHS=<HOULLEVTH
S>][,HODLLEVTHS=<HODLLEVTHS>][,HOULQUALTHS=<HOUL
QUALTHS>][,HODLQUALTHS=<HODLQUALTHS>][,INTRAHOULL
EVTHS=<INTRAHOULLEVTHS>][,INTRAHODLLEVTHS=<INTRAH
ODLLEVTHS>][,HOULLEVP=<HOULLEVP>][,HOULLEVN=<HOUL
LEVN>][,HODLLEVP=<HODLLEVP>][,HODLLEVN=<HODLLEVN>
][,HOULQUALP=<HOULQUALP>][,HOULQUALN=<HOULQUALN>
][,HODLQUALP=<HODLQUALP>][,HODLQUALN=<HODLQUALN>
][,INTRAHOULLEVP=<INTRAHOULLEVP>][,INTRAHOULLEVN=<I
NTRAHOULLEVN>][,INTRAHODLLEVP=<INTRAHODLLEVP>][,INT
RAHODLLEVN=<INTRAHODLLEVN>][,DISTANCEP=<DISTANCEP
>][,DISTANCEN=<DISTANCEN>][,PBGTHON=<PBGTHON>][,PB
GTHOP=<PBGTHOP>][,HOCONTROL=<HOCONTROL>][,HOPATT
ERNIND=<HOPATTERNIND>][,LAYERPRIORITY=<LAYERPRIORI
TY>][,RAPIDHOTHS=<RAPIDHOTHS>][,RAPIDHON=<RAPIDHO
N>][,PBGTHOLAYER=<PBGTHOLAYER>][,MACROMICROHOTHS

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

=<MACROMICROHOTHS>][,MACROMICROHON=<MACROMICRO
HON>][,GOODCITHS=<GOODCITHS>][,GOODCIP=<GOODCIP>
][,GOODCIN=<GOODCIN>][,BADCITHS=<BADCITHS>][,BADCI
P=<BADCIP>][,BADCIN=<BADCIN>][,HOFAILPENALTIME=<HO
FAILPENALTIME>][,DYNPRIOOFFSET=<DYNPRIOOFFSET>][,PBG
TOFFSET=<PBGTOFFSET>][,TRAFFICHOLAYRCTL=<TRAFFICHO
LAYRCTL>][,TRAFFICHOFREQCTL=<TRAFFICHOFREQCTL>][,TR
AFFICTHS=<TRAFFICTHS>][,TAINTRATHS=<TAINTRATHS>][,T
AINTRAHYST=<TAINTRAHYST>][,TAINTRAP=<TAINTRAP>][,TA
INTRAN=<TAINTRAN>][,TRAFFICLEVTHS=<TRAFFICLEVTHS>][
,PENALTYLEVOFFSET=<PENALTYLEVOFFSET>][,QOFFSETUL=<Q
OFFSETUL>][,SOFFSETUL=<SOFFSETUL>][,QOFFSETDL=<QOF
FSETDL>][,SOFFSETDL=<SOFFSETDL>][,TMAXIHO=<TMAXIHO
>][,MAXIHO=<MAXIHO>][,MAXLOSSTHS=<MAXLOSSTHS>][,M
AXTATHS=<MAXTATHS>][,HOFORCEN=<HOFORCEN>][,HOFOR
CEP=<HOFORCEP>][,DULEBANDOFFSET=<DULEBANDOFFSET>
][,PATHLOSSMAX=<PATHLOSSMAX>][,PATHLOSSMIN=<PATHL
OSSMIN>][,SUBCELLTAMAX=<SUBCELLTAMAX>][,SUBCELLTAM
IN=<SUBCELLTAMIN>][,SUBCELLN=<SUBCELLN>][,SUBCELLP
=<SUBCELLP>];
Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

HOCID

HOC ID

Int

USERLABEL

User Label

String

HOULLEVWINDOW

Sample count used for


UL strength
measurement average

Int

HOULLEVWEIGHT

Weighted average of
UL strength

Int

10

HODLLEVWINDOW

Sample count used for


DL strength
measurement average

Int

11

HODLLEVWEIGHT

Weighted average of
DL strength

Int

12

HOULQUALWINDOW

Sample count used for


UL quality
measurement average

Int

13

HOULQUALWEIGHT

Weighted average of
UL quality

Int

14

HODLQUALWINDOW

Sample count used for


DL quality

Int

Confidential and Proprietary Information of ZTE CORPORATION

67

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

No.

Name

Notes

Type

measurement average

68

15

HODLQUALWEIGHT

Weighted average of
DL quality

Int

16

DISTANCEWINDOW

Sample count used for


distance measurement
average

Int

17

NCELLWINDOW

Sample count used for


calculation of
measurement average
for adjacent cell

Int

18

ZEROALLOWED

Quantity to allow zero

Int

19

HOMININTERVAL

Min interval of intercell handover

Int

20

DISTANCETHS

Max distance between


MS and BTS (max time
advance)

Int

21

HOULLEVTHS

UL reception strength
threshold

Int

22

HODLLEVTHS

DL reception strength
threshold

Int

23

HOULQUALTHS

UL reception quality
threshold

Int

24

HODLQUALTHS

DL reception quality
threshold

Int

25

INTRAHOULLEVTHS

UL reception strength
threshold for intra-cell
handover

Int

26

INTRAHODLLEVTHS

DL reception strength
threshold for intra-cell
handover

Int

27

HOULLEVP

UL reception strength
value-p

Int

28

HOULLEVN

UL reception strength
value-n

Int

29

HODLLEVP

DL reception strength
value-p

Int

30

HODLLEVN

DL reception strength
value-n

Int

31

HOULQUALP

UL reception quality
value-p

Int

32

HOULQUALN

UL reception quality
value-n

Int

33

HODLQUALP

DL reception quality
value-p

Int

34

HODLQUALN

DL reception quality
value-n

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

35

INTRAHOULLEVP

UL reception strength
value-p for intra-cell
handover

Int

36

INTRAHOULLEVN

UL reception strength
value-n for intra-cell
handover

Int

37

INTRAHODLLEVP

DL reception strength
value-p for intra-cell
handover

Int

38

INTRAHODLLEVN

DL reception strength
value-n for intra-cell
handover

Int

39

DISTANCEP

Distance handover
value-p

Int

40

DISTANCEN

Distance handover
value-n

Int

41

PBGTHON

PBGT handover value-n

Int

42

PBGTHOP

PBGT handover value-p

Int

43

HOCONTROL

Can do SDCCH
handover

Int

44

HOPATTERNIND

Allowed handover
mode

Int

45

LAYERPRIORITY

Layer priority selection


parameter for level /
quality handover

Int

46

RAPIDHOTHS

Rapid handover
threshold

Int

47

RAPIDHON

Rapid handover valuen

Int

48

PBGTHOLAYER

Layer suitable for


standard PBGT
handover

Int

49

MACROMICROHOTHS

Macro-micro handover
threshold

Int

50

MACROMICROHON

Macro-micro handover
value-n

Int

51

GOODCITHS

C/I threshold while


allowing access to
special TRX

Int

52

GOODCIP

C/I value-p while


allowing access to
special TRX

Int

53

GOODCIN

C/I value-n while


allowing access to
special TRX

Int

54

BADCITHS

C/I threshold while


handover is done from

Int

Confidential and Proprietary Information of ZTE CORPORATION

69

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

No.

Name

Notes

Type

special TRX

70

55

BADCIP

C/I value-p while


handover is done from
special TRX

Int

56

BADCIN

C/I value-n while


handover is done from
special TRX

Int

57

HOFAILPENALTIME

Handover failure
penalty time

Int

58

DYNPRIOOFFSET

Dynamic priority offset

Int

59

PBGTOFFSET

Power budget offset

Int

60

TRAFFICHOLAYRCTL

Layer control value

Int

61

TRAFFICHOFREQCTL

Frequency control
value

Int

62

TRAFFICTHS

Traffic handover
service threshold

Int

63

TAINTRATHS

Intra-cell TA-based
handover threshold

Int

64

TAINTRAHYST

Intra-cell TA-based
handover lagging

Int

65

TAINTRAP

Intra-cell TA-based
handover value-p

Int

66

TAINTRAN

Intra-cell TA-based
handover value-n

Int

67

TRAFFICLEVTHS

Traffic handover level


threshold

Int

68

PENALTYLEVOFFSET

Level offset during


penalty

Int

69

QOFFSETUL

UL interference
handover quality offset

Int

70

SOFFSETUL

UL interference
handover level offset

Int

71

QOFFSETDL

DL interference
handover quality offset

Int

72

SOFFSETDL

DL interference
handover level offset

Int

73

TMAXIHO

Invalid handover
evaluation time

Int

74

MAXIHO

Max invalid handover

Int

75

MAXLOSSTHS

Max path loss allowed


by forcible migration

Int

76

MAXTATHS

Max time advance


allowed by forcible
migration

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

77

HOFORCEN

Value-n on forcible
migration handover
evaluation

Int

78

HOFORCEP

Value-p on forcible
migration handover
evaluation

Int

79

DULEBANDOFFSET

One power
compensation between
frequency band

Int

80

PATHLOSSMAX

Max path loss for intersubcell handover

Int

81

PATHLOSSMIN

Min path loss for intersubcell handover

Int

82

SUBCELLTAMAX

Max time advance for


inter-subcell handover

Int

83

SUBCELLTAMIN

Min time advance for


inter-subcell handover

Int

84

SUBCELLN

Value-n on intersubcell handover


evaluation

Int

85

SUBCELLP

Value-p on intersubcell handover


evaluation

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~10000

1-1

0~40

1-1

1~31

1-1

1~3

1-1

10

1~31

1-1

11

1~3

1-1

12

1~31

1-1

13

1~3

1-1

14

1~31

1-1

15

1~3

1-1

16

1~31

1-1

Default

Instance
Count

Confidential and Proprietary Information of ZTE CORPORATION

71

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

72

Range

17

1~31

1-1

18

0~31

1-1

19

0~31

1-1

20

0~219

1-1

21

0~63

1-1

22

0~63

1-1

23

0~7

1-1

24

0~7

1-1

25

0~63

1-1

26

0~63

1-1

27

1~31

1-1

28

1~31

1-1

29

1~31

1-1

30

1~31

1-1

31

1~31

1-1

32

1~31

1-1

33

1~31

1-1

34

1~31

1-1

35

1~31

1-1

36

1~31

1-1

37

1~31

1-1

38

1~31

1-1

39

1~31

1-1

40

1~31

1-1

41

1~31

1-1

42

1~31

1-1

43

0~262143

1-1

44

0~10000

1-1

45

1~3

1-1

46

0~63

1-1

47

1~31

1-1

48

0~15

1-1

49

0~62

1-1

50

1~255

1-1

51

0~255

1-1

52

1~31

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Default

Instance
Count

No.

Chapter 2 - Single Command Processing

Output
Parameters

Default

Instance
Count

No.

Range

53

1~31

1-1

54

0~255

1-1

55

1~31

1-1

56

1~31

1-1

57

1~255

1-1

58

1~7

1-1

59

0~20

1-1

60

0~3

1-1

61

0~7

1-1

62

0~100

1-1

63

1~63

1-1

64

1~5

1-1

65

1~32

1-1

66

1~32

1-1

67

0~48

1-1

68

0~63

1-1

69

0~2

1-1

70

0~20

1-1

71

0~2

1-1

72

0~20

1-1

73

0~255

1-1

74

0~10

1-1

75

0~150

1-1

76

0~63

1-1

77

1~31

1-1

78

1~31

1-1

79

0~50

1-1

80

0~150

1-1

81

0~150

1-1

82

0~63

1-1

83

0~63

1-1

84

1~10

1-1

85

1~10

1-1

Description of output parameters is as follows:

Confidential and Proprietary Information of ZTE CORPORATION

73

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Example

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

SET
HOC:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1
,HOCID=1,USERLABEL="0",HOULLEVWINDOW=1,HOULLEVWEI
GHT=1,HODLLEVWINDOW=1,HODLLEVWEIGHT=1,HOULQUALW
INDOW=1,HOULQUALWEIGHT=1,HODLQUALWINDOW=1,HODL
QUALWEIGHT=1,DISTANCEWINDOW=1,NCELLWINDOW=1,ZER
OALLOWED=0,HOMININTERVAL=0,DISTANCETHS=0,HOULLEVT
HS=0,HODLLEVTHS=0,HOULQUALTHS=0,HODLQUALTHS=0,INT
RAHOULLEVTHS=0,INTRAHODLLEVTHS=0,HOULLEVP=1,HOULLE
VN=1,HODLLEVP=1,HODLLEVN=1,HOULQUALP=1,HOULQUALN=
1,HODLQUALP=1,HODLQUALN=1,INTRAHOULLEVP=1,INTRAHO
ULLEVN=1,INTRAHODLLEVP=1,INTRAHODLLEVN=1,DISTANCEP
=1,DISTANCEN=1,PBGTHON=1,PBGTHOP=1,HOCONTROL=0,HO
PATTERNIND=0,LAYERPRIORITY=1,RAPIDHOTHS=0,RAPIDHON
=1,PBGTHOLAYER=0,MACROMICROHOTHS=0,MACROMICROHO
N=1,GOODCITHS=0,GOODCIP=1,GOODCIN=1,BADCITHS=0,BA
DCIP=1,BADCIN=1,HOFAILPENALTIME=1,DYNPRIOOFFSET=1,P
BGTOFFSET=0,TRAFFICHOLAYRCTL=0,TRAFFICHOFREQCTL=0,T
RAFFICTHS=0,TAINTRATHS=1,TAINTRAHYST=1,TAINTRAP=1,T
AINTRAN=1,TRAFFICLEVTHS=0,PENALTYLEVOFFSET=0,QOFFSE
TUL=0,SOFFSETUL=0,QOFFSETDL=0,SOFFSETDL=0,TMAXIHO=
0,MAXIHO=0,MAXLOSSTHS=0,MAXTATHS=0,
HOFORCEN=1,HOFORCEP=1,DULEBANDOFFSET=0,PATHLOSSM
AX=0,PATHLOSSMIN=0,SUBCELLTAMAX=0,SUBCELLTAMIN=0,S
UBCELLN=1,SUBCELLP=1;

Display UTRAN Cell Handover Control


Prompt

SHW 3GHOC

Format

SHW
3GHOC:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID
>][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][
,S3GHOCID=<S3GHOCID>],PARAMS=<PARAMS>;

Input
Parameters

74

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

S3GHOCID

Cell UTRAN

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

handover control
no.

Output
Parameters

Example

PARAMS

Parameter List

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

0~10000

1-1

0~1000

Default

""

String

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

36

INFO

Complex

Query Result

1-10000

SHW
3GHOC:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID
=1,S3GHOCID=0,PARAMS=" ";

Modify UTRAN Cell Handover Control


Prompt

SET 3GHOC

Format

SET
3GHOC:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID
>][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][
,S3GHOCID=<S3GHOCID>][,USERLABEL=<USERLABEL>][,HOF
AILPENALTM3G=<HOFAILPENALTM3G>][,HOWINDOW3G=<HO
WINDOW3G>][,ZEROALLOWED3G=<ZEROALLOWED3G>][,FDD
TDDPRIO=<FDDTDDPRIO>][,SERVICEHO=<SERVICEHO>][,INT
ERSYSHOCTRL=<INTERSYSHOCTRL>][,INTERSYSRDCTRL=<INT
ERSYSRDCTRL>][,HORSCPTHSFDD=<HORSCPTHSFDD>][,HORS
CP_P_FDD=<HORSCP_P_FDD>][,HORSCP_N_FDD=<HORSCP_N
_FDD>][,HOECNOTHSFDD=<HOECNOTHSFDD>][,HOECNO_P_F
DD=<HOECNO_P_FDD>][,HOECNO_N_FDD=<HOECNO_N_FDD

Confidential and Proprietary Information of ZTE CORPORATION

75

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

>][,HORSCPTHSTDD=<HORSCPTHSTDD>][,HORSCP_N_TDD=<
HORSCP_N_TDD>][,HORSCP_P_TDD=<HORSCP_P_TDD>];
Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

S3GHOCID

Cell UTRAN
handover control
number

Int

USERLABEL

User Label

String

HOFAILPENALTM3G

UTRAN cell
handover failure
penalty time

Int

HOWINDOW3G

Sliding window
value used while
calculating UTRAN
adjacent cell Ec/No
or RSCP

Int

10

ZEROALLOWED3G

Quantity to allow
zero in UTRAN
adjacent cell
measurement value

Int

11

FDDTDDPRIO

FDD/TDD Handover

Int

12

SERVICEHO

UTRAN Handover

Int

13

INTERSYSHOCTRL

Support intersystem handover


within BSC

Int

14

INTERSYSRDCTRL

Allow directional
retry for UTRAN cell

Int

15

HORSCPTHSFDD

RSCP threshold on
handover from GSM
to UTRAN

Int

16

HORSCP_P_FDD

FDD cell HORSCP-P


value

Int

17

HORSCP_N_FDD

FDD cell HORSCP-N


value

Int

18

HOECNOTHSFDD

Ec/No threshold on
handover from GSM
to FDD

Int

19

HOECNO_P_FDD

FDD cell HOECNO


value-p

Int

76

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

20

HOECNO_N_FDD

FDD cell HOECNO


value-n

Int

21

HORSCPTHSTDD

RSCP threshold on
handover from GSM
to TDD

Int

22

HORSCP_N_TDD

Value-n used on
handover evaluation
from GSM to TDD

Int

23

HORSCP_P_TDD

Value-p used on
handover evaluation
from GSM to TDD

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

0~10000

1-1

0~40

1-1

1~255

1-1

1~31

1-1

10

0~31

1-1

11

0~1

1-1

12

0~5

1-1

13

0~1

1-1

14

0~1

1-1

15

0~63

1-1

16

1~20

1-1

17

1~20

1-1

18

0~49

1-1

19

1~20

1-1

20

1~20

1-1

21

0~63

1-1

22

1~20

1-1

23

1~20

1-1

Default

Instance
Count

Confidential and Proprietary Information of ZTE CORPORATION

77

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

SET
3GHOC:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID
=1,S3GHOCID=0,USERLABEL="0",HOFAILPENALTM3G=1,HOWI
NDOW3G=1,ZEROALLOWED3G=0,FDDTDDPRIO=0,SERVICEHO
=0,INTERSYSHOCTRL=0,INTERSYSRDCTRL=0,HORSCPTHSFDD
=0,HORSCP_P_FDD=1,HORSCP_N_FDD=1,HOECNOTHSFDD=0,
HOECNO_P_FDD=1,HOECNO_N_FDD=1,HORSCPTHSTDD=0,HO
RSCP_N_TDD=1,HORSCP_P_TDD=1;

Display UTRAN Cell Control


Prompt

SHW 3GBTS

Format

SHW
3GBTS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID
>][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][
,S3GBTSID=<S3GBTSID>],PARAMS=<PARAMS>;

Input
Parameters

78

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

S3GBTSID

Cell UTRAN Control No.

Int

PARAMS

Parameter List

String

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Default

Instance
Count

No.

Chapter 2 - Single Command Processing

Output
Parameters

Example

No.

Range

0~10000

0~1000

Default

Instance
Count
1-1

""

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

61

INFO

Complex

Query Result

1-10000

SHW
3GBTS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID
=1,S3GBTSID=0,PARAMS=" ";

Modify UTRAN Cell Control


Prompt

SET 3GBTS

Format

SET
3GBTS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID
>][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][
,S3GBTSID=<S3GBTSID>][,USERLABEL=<USERLABEL>][,ECSC
_3G=<ECSC_3G>][,SI2QUATERPOS=<SI2QUATERPOS>][,REPO
RTTYPECS=<REPORTTYPECS>][,SVRBANDRPRTCS=<SVRBAND
RPRTCS>][,QSEARCH_I=<QSEARCH_I>][,FDD_QOFFSET=<FD
D_QOFFSET>][,FDD_QMIN=<FDD_QMIN>][,QSEARCHCINIT=<
QSEARCHCINIT>][,QSEARCH_C=<QSEARCH_C>][,FDDREPQNT
CS=<FDDREPQNTCS>][,FDDMULRATRRPTCS=<FDDMULRATRRP
TCS>][,REPORTRATECS=<REPORTRATECS>][,INVLDBSICRPRTC
S=<INVLDBSICRPRTCS>][,MULBNDRPRTCS=<MULBNDRPRTCS
>][,SCALEORDCS=<SCALEORDCS>][,RPRTOFFSETCS900=<RP
RTOFFSETCS900>][,RPRTTHOCS900=<RPRTTHOCS900>][,RPR
TOFFSETCS1800=<RPRTOFFSETCS1800>][,RPRTTHOCS1800=<
RPRTTHOCS1800>][,RPRTOFFSETCS1900=<RPRTOFFSETCS190
0>][,RPRTTHOCS1900=<RPRTTHOCS1900>][,FDDRPRTOFFSET
CS=<FDDRPRTOFFSETCS>][,FDDRPRTTHOCS=<FDDRPRTTHOC
S>][,SEARCHPRIOCS3G=<SEARCHPRIOCS3G>][,RPRTTHOCS85
0=<RPRTTHOCS850>][,RPRTOFFSETCS850=<RPRTOFFSETCS8
50>][,TDD_QOFFSET=<TDD_QOFFSET>][,TDDMULRATRRPTCS
=<TDDMULRATRRPTCS>][,TDDRPRTOFFSETCS=<TDDRPRTOFF
SETCS>][,TDDRPRTTHOCS=<TDDRPRTTHOCS>][,REPORTTYPEP
S=<REPORTTYPEPS>][,SVRBANDRPRTPS=<SVRBANDRPRTPS>]
[,FDDREPQNTPS=<FDDREPQNTPS>][,FDDMULRATRRPTPS=<FD
DMULRATRRPTPS>][,REPORTRATEPS=<REPORTRATEPS>][,INV
LDBSICRPRTPS=<INVLDBSICRPRTPS>][,MULBNDRPRTPS=<MU
LBNDRPRTPS>][,SCALEORDPS=<SCALEORDPS>][,RPRTOFFSET

Confidential and Proprietary Information of ZTE CORPORATION

79

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

PS900=<RPRTOFFSETPS900>][,RPRTTHOPS900=<RPRTTHOPS9
00>][,RPRTOFFSETPS1800=<RPRTOFFSETPS1800>][,RPRTTHO
PS1800=<RPRTTHOPS1800>][,RPRTOFFSETPS1900=<RPRTOFF
SETPS1900>][,RPRTTHOPS1900=<RPRTTHOPS1900>][,FDDRPR
TOFFSETPS=<FDDRPRTOFFSETPS>][,FDDRPRTTHOPS=<FDDRP
RTTHOPS>][,SEARCHPRIOPS3G=<SEARCHPRIOPS3G>][,RPRTT
HOPS850=<RPRTTHOPS850>][,RPRTOFFSETPS850=<RPRTOFF
SETPS850>][,TDDMULRATRRPTPS=<TDDMULRATRRPTPS>][,TD
DRPRTOFFSETPS=<TDDRPRTOFFSETPS>][,TDDRPRTTHOPS=<T
DDRPRTTHOPS>];
Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

S3GBTSID

Cell UTRAN control


number

Int

USERLABEL

User Label

String

ECSC_3G

Whether UE is
required while
sending UTRAN
classmark change
message

Int

SI2QUATERPOS

Channel position of
SI2 quater
broadcast

Int

10

REPORTTYPECS

Information type of
UE measurement
report submitted

Int

SVRBANDRPRTCS

Report number CS
for adjacent cell
with same
frequency

Int

12

QSEARCH_I

Threshold while UE
starts UTRAN
reselection cell
measurement

Int

13

FDD_QOFFSET

FDD reselection
offset

Int

14

FDD_QMIN

Min UTRAN
reselection cell
code-to-noise ratio

Int

15

QSEARCHCINIT

Replace Qsearch_C
before UE hasnt
gained Qsearch_C

Int

11

80

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

parameter

16

QSEARCH_C

Threshold while UE
starts UTRAN
adjacent cell search
under special mode

17

FDDREPQNTCS

Quantity type CS of
UTRAN adjacent cell
reported

Int

FDDMULRATRRPTCS

Max quantity of
UTRAN/FDD
adjacent cell
included in
measurement
report

Int

REPORTRATECS

Frequency CS of
measurement
report submitted
within adjacent cell

Int

20

INVLDBSICRPRTCS

Whether allow UE
reports field
strength CS of
invalid cell

Int

21

MULBNDRPRTCS

Multiple band
indication CS

Int

22

SCALEORDCS

Offset CS added
while UE reports
signal field strength

Int

RPRTOFFSETCS900

Signal level offset


while GSM900M
adjacent cell selects
submission

Int

RPRTTHOCS900

Signal level
threshold while
GSM900M adjacent
cell selects
submission

Int

RPRTOFFSETCS1800

Signal level offset


while GSM1800M
adjacent cell selects
submission

Int

RPRTTHOCS1800

Signal level
threshold while
GSM1800M adjacent
cell selects
submission

Int

27

RPRTOFFSETCS1900

Signal level offset


while GSM1900M
adjacent cell selects
submission

Int

28

RPRTTHOCS1900

Signal level
threshold while

Int

18

19

23

24

25

26

Int

Confidential and Proprietary Information of ZTE CORPORATION

81

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

No.

Name

Notes

Type

GSM1900M adjacent
cell selects
submission

FDDRPRTOFFSETCS

Signal level offset


while UTRAN/FD
adjacent cell selects
submission

Int

FDDRPRTTHOCS

Signal level
threshold while
UTRAN/FD adjacent
cell selects
submission

Int

SEARCHPRIOCS3G

UE searches for
UTRAN adjacent cell
CS while requiring
BSIC decoding
frame

Int

RPRTTHOCS850

Signal level
threshold while
GSM850M adjacent
cell selects
submission

Int

33

RPRTOFFSETCS850

Signal level offset


while GSM850M
adjacent cell selects
submission

Int

34

TDD_QOFFSET

TDD reselection
offset CS

Int

TDDMULRATRRPTCS

Max quantity CS of
TDD adjacent cell
included in
measurement
report

Int

TDDRPRTOFFSETCS

Signal level offset


while UTRAN/TDD
adjacent cell selects
submission

Int

37

TDDRPRTTHOCS

Signal level
threshold while
UTRAN/TDD
adjacent cell selects
submission

Int

38

REPORTTYPEPS

Message type PS of
UE measurement
report submitted

Int

39

SVRBANDRPRTPS

Report number PS
for adjacent cell
with same
frequency

Int

40

FDDREPQNTPS

Quantity type PS of
UTRAN adjacent cell

Int

29

30

31

32

35

36

82

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

No.

Name

Notes

Type

reported

FDDMULRATRRPTPS

Max quantity PS of
UTRAN/FDD
adjacent cell
included in
measurement
report

Int

42

REPORTRATEPS

Frequency PS of
measurement
report submitted
within adjacent cell

Int

43

INVLDBSICRPRTPS

Allow UE report
invalid cell field
strength PS

Int

44

MULBNDRPRTPS

Multiple band report


PS

Int

45

SCALEORDPS

Offset PS added
while UE reports
signal field strength

Int

RPRTOFFSETPS900

Signal level offset


while GSM900M
adjacent cell selects
submission

Int

RPRTTHOPS900

Signal level
threshold while
GSM900M adjacent
cell selects
submission

Int

RPRTOFFSETPS1800

Signal level offset


while GSM1800M
adjacent cell selects
submission

Int

RPRTTHOPS1800

Signal level
threshold while
GSM1800M adjacent
cell selects
submission

Int

RPRTOFFSETPS1900

Signal level offset


while GSM1900M
adjacent cell selects
submission

Int

RPRTTHOPS1900

Signal level
threshold while
GSM1900M adjacent
cell selects
submission

Int

FDDRPRTOFFSETPS

Signal level offset


while UTRAN/FD
adjacent cell selects
submission

Int

41

46

47

48

49

50

51

52

Confidential and Proprietary Information of ZTE CORPORATION

83

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

No.

Name

Notes

Type

FDDRPRTTHOPS

Signal level
threshold while
UTRAN/FD adjacent
cell selects
submission

Int

SEARCHPRIOPS3G

UE searches for
UTRAN adjacent cell
PS while requiring
BSIC decoding
frame

Int

RPRTTHOPS850

Signal level
threshold while
GSM850M adjacent
cell selects
submission

Int

RPRTOFFSETPS850

Signal level offset


while GSM850M
adjacent cell selects
submission

Int

TDDMULRATRRPTPS

Max quantity of TDD


adjacent cell
included in
measurement
report (GPRS)

Int

TDDRPRTOFFSETPS

Signal level offset


while TDD adjacent
cell selects
submission (GPRS)

Int

59

TDDRPRTTHOPS

Signal level
threshold while TDD
adjacent cell selects
submission

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

0~10000

1-1

0~40

1-1

0~1

1-1

0~1

1-1

10

0~1

1-1

11

0~3

1-1

53

54

55

56

57

58

84

Confidential and Proprietary Information of ZTE CORPORATION

Default

Instance
Count

Chapter 2 - Single Command Processing

Default

Instance
Count

No.

Range

12

0~15

1-1

13

0~15

1-1

14

0~7

1-1

15

0~1

1-1

16

0~15

1-1

17

0~1

1-1

18

0~3

1-1

19

0~1

1-1

20

0~1

1-1

21

0~3

1-1

22

0~2

1-1

23

0~7

1-1

24

0~7

1-1

25

0~7

1-1

26

0~7

1-1

27

0~7

1-1

28

0~7

1-1

29

0~10000

1-1

30

0~10000

1-1

31

0~1

1-1

32

0~7

1-1

33

0~7

1-1

34

0~15

1-1

35

0~3

1-1

36

0~7

1-1

37

0~7

1-1

38

0~1

1-1

39

0~3

1-1

40

0~1

1-1

41

0~3

1-1

42

0~1

1-1

43

0~1

1-1

44

0~3

1-1

45

0~2

1-1

46

0~7

1-1

47

0~7

1-1

Confidential and Proprietary Information of ZTE CORPORATION

85

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Range

48

0~7

1-1

49

0~7

1-1

50

0~7

1-1

51

0~7

1-1

52

0~7

1-1

53

0~7

1-1

54

0~1

1-1

55

0~7

1-1

56

0~7

1-1

57

0~3

1-1

58

0~7

1-1

59

0~7

1-1

Description of output parameters is as follows:

No.
2

Example

86

Default

Instance
Count

No.

Name
DETAIL

Type
String

Notes
Details

Instance
Count
1-1

SET
3GBTS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID
=1,S3GBTSID=0,USERLABEL="0",ECSC_3G=0,SI2QUATERPOS=
0,REPORTTYPECS=0,SVRBANDRPRTCS=0,QSEARCH_I=0,FDD_Q
OFFSET=0,FDD_QMIN=0,QSEARCHCINIT=0,QSEARCH_C=0,FD
DREPQNTCS=0,FDDMULRATRRPTCS=0,REPORTRATECS=0,INVL
DBSICRPRTCS=0,MULBNDRPRTCS=0,SCALEORDCS=0,RPRTOFF
SETCS900=0,RPRTTHOCS900=0,RPRTOFFSETCS1800=0,RPRTT
HOCS1800=0,RPRTOFFSETCS1900=0,RPRTTHOCS1900=0,FDDR
PRTOFFSETCS=0,FDDRPRTTHOCS=0,SEARCHPRIOCS3G=0,RPR
TTHOCS850=0,RPRTOFFSETCS850=0,TDD_QOFFSET=0,TDDMU
LRATRRPTCS=0,TDDRPRTOFFSETCS=0,TDDRPRTTHOCS=0,REP
ORTTYPEPS=0,SVRBANDRPRTPS=0,FDDREPQNTPS=0,FDDMULR
ATRRPTPS=0,REPORTRATEPS=0,INVLDBSICRPRTPS=0,MULBND
RPRTPS=0,SCALEORDPS=0,RPRTOFFSETPS900=0,RPRTTHOPS9
00=0,RPRTOFFSETPS1800=0,RPRTTHOPS1800=0,RPRTOFFSETP
S1900=0,RPRTTHOPS1900=0,FDDRPRTOFFSETPS=0,FDDRPRTT
HOPS=0,SEARCHPRIOPS3G=0,RPRTTHOPS850=0,RPRTOFFSETP
S850=0,TDDMULRATRRPTPS=0,TDDRPRTOFFSETPS=0,TDDRPR
TTHOPS=0;

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Create Adjacent Cell Handover


Prompt

ADD HO

Format

ADD
HO:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,BSCI
D=<BSCID>,SITEID=<SITEID>,BTSID=<BTSID>,ACID=<ACID
>[,USERLABEL=<USERLABEL>],RELATIONDN=<RELATIONDN>[
,HOPRIORITY=<HOPRIORITY>][,MSTXPWRMAX=<MSTXPWRMA
X>][,RXLEVMIN=<RXLEVMIN>][,HOMARGINPBGT=<HOMARGIN
PBGT>][,HOMARGINRXLEV=<HOMARGINRXLEV>][,HOMARGINR
XQUAL=<HOMARGINRXQUAL>][,MAXFORCEHODIFF=<MAXFOR
CEHODIFF>][,HOFORCERESTHS=<HOFORCERESTHS>][,NCELLL
AYER=<NCELLLAYER>][,REPPRIOCS=<REPPRIOCS>][,ISRELAT
EDCELL=<ISRELATEDCELL>][,ISHOFORCENCELL=<ISHOFORCE
NCELL>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Handover Cell ID

Int

USERLABEL

User Label

String

RELATIONDN

Related Cell ID

String

HOPRIORITY

Cell handover
priority

Int

10

MSTXPWRMAX

MS max power
level

Int

11

RXLEVMIN

Min reception
strength level

Int

12

HOMARGINPBGT

PBGT min handover


threshold

Int

13

HOMARGINRXLEV

Strength handover
min threshold

Int

14

HOMARGINRXQUAL

Quality handover
min threshold

Int

15

MAXFORCEHODIFF

Max level offset for


forcible migration
handover

Int

16

HOFORCERESTHS

Migration
reservation
resource threshold

Int

Confidential and Proprietary Information of ZTE CORPORATION

87

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

88

No.

Name

Notes

Type

17

NCELLLAYER

Adjacent cell layer

Enumeratio
n

18

REPPRIOCS

Priority CS of
measurement
report submitted
within adjacent cell

Enumeratio
n

19

ISRELATEDCELL

Is related cell

Enumeratio
n

20

ISHOFORCENCELL

Is forcible
migration cell

Enumeratio
n

Default

Instance
Count

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

0~40

0~512

0~7

1-1

10

0~31

1-1

11

0~63

15

1-1

12

0~48

30

1-1

13

0~48

30

1-1

14

0~48

30

1-1

15

0~48

1-1

16

0~100

40

1-1

17

NCELLLAYER_1

1-1

18

REPPRIOCS_0

1-1

19

BOOLEAN_NO

1-1

20

BOOLEAN_NO

1-1

""

1-1
1-1

Description of output parameters as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Enumeration
Description

Priority information submitted by measurement report is as


follows:
Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

BOOLEAN information is as follows:


Macro Name

Meaning

BOOLEAN_NO

No

BOOLEAN_YES

Yes

Layer information of adjacent cell is as follows:


Macro Name

Meaning

NCELLLAYER_0

undefined

NCELLLAYER_1

At same layer as this cell

NCELLLAYER_2

Is upper layer of this cell

NCELLLAYER_3

Is lower layer of this cell

Example

ADD
HO:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
ACID=1,USERLABEL="",RELATIONDN="0",HOPRIORITY=3,MSTX
PWRMAX=5,RXLEVMIN=15,HOMARGINPBGT=30,HOMARGINRXL
EV=30,HOMARGINRXQUAL=30,MAXFORCEHODIFF=9,HOFORCE
RESTHS=40,NCELLLAYER=NCELLLAYER_1,REPPRIOCS=REPPRIO
CS_0,ISRELATEDCELL=BOOLEAN_NO,ISHOFORCENCELL=BOOLE
AN_NO;

Remarks

Dn format in relevant cell:


RELATIONDN="SITEID=1,BTSID=1";RELATIONDN="GERANECEL
LID=111";RELATIONDN="EC3GID=111"

Delete Adjacent Cell Handover


Prompt

DEL HO

Format

DEL
HO:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,AC
ID=<ACID>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

89

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

No.

Name

Notes

Type

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Handover Cell ID

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

Default

Instance
Count

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL
HO:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
ACID=1;

Display Adjacent Cell Handover


Prompt

SHW HO

Format

SHW
HO:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,AC
ID=<ACID>][,PARAMS=<PARAMS>];

Input
Parameters

90

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Example

No.

Name

Notes

Type

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Handover Cell ID

Int

PARAMS

Parameter List

String

No.

Range

Default

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

0~1000

""

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

22

INFO

Complex

Query Result

1-10000

SHW
HO:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
ACID=1,PARAMS=" ";

Modify Adjacent Cell Handover


Prompt

SET HO

Format

SET
HO:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,
BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,AC
ID=<ACID>][,USERLABEL=<USERLABEL>][,HOPRIORITY=<HO
PRIORITY>][,MSTXPWRMAX=<MSTXPWRMAX>][,RXLEVMIN=<
RXLEVMIN>][,HOMARGINPBGT=<HOMARGINPBGT>][,HOMARGI
NRXLEV=<HOMARGINRXLEV>][,HOMARGINRXQUAL=<HOMARG
INRXQUAL>][,ISRELATEDCELL=<ISRELATEDCELL>][,NCELLLAY
ER=<NCELLLAYER>][,ISHOFORCENCELL=<ISHOFORCENCELL>]

Confidential and Proprietary Information of ZTE CORPORATION

91

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

[,MAXFORCEHODIFF=<MAXFORCEHODIFF>][,HOFORCERESTHS
=<HOFORCERESTHS>][,REPPRIOCS=<REPPRIOCS>];
Input
Parameters

92

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Handover Cell ID

Int

USERLABEL

User Label

String

HOPRIORITY

Cell handover priority

Int

MSTXPWRMAX

MS max power level

Int

10

RXLEVMIN

Min reception strength


level

Int

11

HOMARGINPBGT

PBGT min handover


threshold

Int

12

HOMARGINRXLEV

Strength handover min


threshold

Int

13

HOMARGINRXQUAL

Quality handover min


threshold

Int

14

ISRELATEDCELL

Is related cell

Int

15

NCELLLAYER

Adjacent cell layer

Enumera
tion

16

ISHOFORCENCELL

Is forcible migration cell

Enumera
tion

17

MAXFORCEHODIFF

Max level offset for


forcible migration
handover

Int

18

HOFORCERESTHS

Migration reservation
resource threshold

Int

19

REPPRIOCS

Priority (CS) of
measurement report
submitted within
adjacent cell

Enumera
tion

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Default

Instance
Count

Chapter 2 - Single Command Processing

Default

Range

1~1536

1-1

1~24

1-1

1~32

1-1

0~40

1-1

0~7

1-1

0~31

1-1

10

0~63

1-1

11

0~48

1-1

12

0~48

1-1

13

0~48

1-1

14

0~1

1-1

15

NCELLLAYER_
1

1-1

16

BOOLEAN_NO

1-1

17

0~48

1-1

18

0~100

1-1
REPPRIOCS_
0

19

Output
Parameters

Enumeration
Description

Instance
Count

No.

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:

Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

BOOLEAN information is as follows:


Macro Name

Meaning

BOOLEAN_NO

No

BOOLEAN_YES

Yes

Layer information of adjacent cell is shown as follows:

Confidential and Proprietary Information of ZTE CORPORATION

93

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Example

Macro Name

Meaning

NCELLLAYER_0

undefined

NCELLLAYER_1

At same layer as this cell

NCELLLAYER_2

Is upper layer of this cell

NCELLLAYER_3

Is lower layer of this cell

SET
HO:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,
ACID=1,USERLABEL="0",HOPRIORITY=0,MSTXPWRMAX=0,RXL
EVMIN=0,HOMARGINPBGT=0,HOMARGINRXLEV=0,HOMARGINR
XQUAL=0,ISRELATEDCELL=0,NCELLLAYER=NCELLLAYER_1,ISH
OFORCENCELL=BOOLEAN_NO,MAXFORCEHODIFF=0,HOFORCER
ESTHS=0,REPPRIOCS=REPPRIOCS_0;

Create Adjacent Cell Reselection


Prompt

ADD RS

Format

ADD
RS:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,BSCI
D=<BSCID>,SITEID=<SITEID>,BTSID=<BTSID>,ACID=<ACID
>[,USERLABEL=<USERLABEL>][,REPPRIOPS=<REPPRIOPS>],R
ELATIONDN=<RELATIONDN>;

Input
Parameters

94

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Reselect Cell ID

Int

USERLABEL

User Label

String

REPPRIOPS

Priority of
measurement report
submitted

Enumeratio
n

RELATIONDN

Related Cell ID

String

No.

Range

1~4095

1-1

0~2147483647

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Default

Instance
Count

Chapter 2 - Single Command Processing

Output
Parameters

Enumeration
Description

Default

Instance
Count

No.

Range

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

0~40

""

1-1

0~1

REPPRIOCS_0

1-1

0~512

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:
Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

Example

ADD
RS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,A
CID=1,USERLABEL="",REPPRIOPS=REPPRIOCS_0,RELATIONDN
="0";

Remarks

Dn format in relevant cell:


RELATIONDN="SITEID=1,BTSID=1";RELATIONDN="GERANECEL
LID=111";RELATIONDN="EC3GID=111"

Delete Adjacent Cell Reselection


Prompt

DEL RS

Format

DEL
RS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,B
SCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,ACI
D=<ACID>];

Input
Parameters

Description of input parameters is as follows:

Confidential and Proprietary Information of ZTE CORPORATION

95

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Reselect Cell ID

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

Default

Instance
Count

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL
RS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,A
CID=1;

Display Adjacent Cell Reselection


Prompt

SHW RS

Format

SHW
RS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,B
SCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,ACI
D=<ACID>][,PARAMS=<PARAMS>];

Input
Parameters

96

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Example

No.

Name

Notes

Type

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Reselect Cell ID

Int

PARAMS

Parameter List

String

No.

Range

Default

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

0~1000

""

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

11

INFO

Complex

Query Result

1-10000

SHW
RS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,A
CID=1,PARAMS=" ";

Modify Adjacent Cell Reselection


Prompt

SET RS

Format

SET
RS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][,B
SCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,ACI
D=<ACID>][,USERLABEL=<USERLABEL>][,REPPRIOPS=<REPP
RIOPS>];

Input
Parameters

Description of input parameters is as follows:

Confidential and Proprietary Information of ZTE CORPORATION

97

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Enumeration
Description

Example

98

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Object ID

Int

USERLABEL

User Label

String

REPPRIOPS

Priority of
measurement
report submitted
(PS)

Enumeratio
n

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

0~40

1-1

0~1

Default

REPPRIOCS_0

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:
Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

SET
RS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1,A
CID=1,USERLABEL="0",REPPRIOPS=REPPRIOCS_0;

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Create Adjacent Cell Reselection and Handover


Prompt

ADD HORS

Format

ADD
HORS:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,BS
CID=<BSCID>,SITEID=<SITEID>,BTSID=<BTSID>,ACID=<AC
ID>[,USERLABEL=<USERLABEL>],RELATIONDN=<RELATIONDN
>[,HOPRIORITY=<HOPRIORITY>][,MSTXPWRMAX=<MSTXPWR
MAX>][,RXLEVMIN=<RXLEVMIN>][,HOMARGINPBGT=<HOMAR
GINPBGT>][,HOMARGINRXLEV=<HOMARGINRXLEV>][,HOMARG
INRXQUAL=<HOMARGINRXQUAL>][,MAXFORCEHODIFF=<MAXF
ORCEHODIFF>][,HOFORCERESTHS=<HOFORCERESTHS>][,NCE
LLLAYER=<NCELLLAYER>][,REPPRIOCS=<REPPRIOCS>][,REPP
RIOPS=<REPPRIOPS>][,ISRELATEDCELL=<ISRELATEDCELL>][,
ISHOFORCENCELL=<ISHOFORCENCELL>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Reselect and
Handover Cell ID

Int

USERLABEL

User Label

String

RELATIONDN

Related Cell ID

String

HOPRIORITY

Cell handover priority

Int

10

MSTXPWRMAX

MS max power level

Int

11

RXLEVMIN

Min reception strength


level

Int

12

HOMARGINPBGT

PBGT min handover


threshold

Int

13

HOMARGINRXLEV

Strength handover
min threshold

Int

14

HOMARGINRXQUAL

Quality handover min


threshold

Int

15

MAXFORCEHODIFF

Max level offset for


forcible migration
handover

Int

16

HOFORCERESTHS

Migration reservation
resource threshold

Int

17

NCELLLAYER

Adjacent cell layer

Enumera
tion

Confidential and Proprietary Information of ZTE CORPORATION

99

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

No.

Name

Notes

Type

REPPRIOCS

Priority CS of
measurement report
submitted within
adjacent cell

Enumera
tion

19

REPPRIOPS

Priority PS of
measurement report
submitted within
adjacent cell

Enumera
tion

20

ISRELATEDCELL

Is related cell

Int

21

ISHOFORCENCELL

Is forcible migration
cell

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

0~40

0~512

0~7

1-1

10

0~31

1-1

11

0~63

15

1-1

12

0~48

30

1-1

13

0~48

30

1-1

14

0~48

30

1-1

15

0~48

1-1

16

0~100

40

1-1

NCELLLAY
ER_1

1-1

18

17

100

Default

""

Instance
Count

1-1
1-1

18

0~1

REPPRIOC
S_0

1-1

19

0~1

REPPRIOC
S_0

1-1

20

0~1

1-1

21

0~1

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Enumeration
Description

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:
Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

Layer information of adjacent cell is shown as follows:


Macro Name

Meaning

NCELLLAYER_0

undefined

NCELLLAYER_1

At same layer as this cell

NCELLLAYER_2

Is upper layer of this cell

NCELLLAYER_3

Is lower layer of this cell

Example

ADD
HORS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1,USERLABEL="",RELATIONDN="0",HOPRIORITY=0,MS
TXPWRMAX=5,RXLEVMIN=15,HOMARGINPBGT=30,HOMARGINR
XLEV=30,HOMARGINRXQUAL=30,MAXFORCEHODIFF=9,HOFORC
ERESTHS=40,NCELLLAYER=NCELLLAYER_1,REPPRIOCS=REPPRI
OCS_0,REPPRIOPS=REPPRIOCS_0,ISRELATEDCELL=0,ISHOFOR
CENCELL=0;

Remarks

Dn format in relevant cell:


RELATIONDN="SITEID=1,BTSID=1";RELATIONDN="GERANECEL
LID=111";RELATIONDN="EC3GID=111"

Delete Adjacent Cell Reselection and Handover


Prompt

DEL HORS

Format

DEL
HORS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>
][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,
ACID=<ACID>];

Input
Parameters

Description of input parameters is as follows:


No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

101

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

No.

Name

Notes

Type

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Reselect and
Handover Cell ID

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

Default

Instance
Count

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL
HORS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1;

Display Adjacent Cell Reselection and Handover


Prompt

SHW HORS

Format

SHW
HORS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>
][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,
ACID=<ACID>][,PARAMS=<PARAMS>];

Input
Parameters

102

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Example

No.

Name

Notes

Type

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Reselect and
Handover Cell ID

Int

PARAMS

Parameter List

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

0~1000

Default

""

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

23

INFO

Complex

Query Result

1-10000

SHW
HORS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1,PARAMS=" ";

Modify Adjacent Cell Reselection and Handover


Prompt

SET HORS

Format

SET
HORS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>
][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,
ACID=<ACID>][,USERLABEL=<USERLABEL>][,HOPRIORITY=<
HOPRIORITY>][,MSTXPWRMAX=<MSTXPWRMAX>][,RXLEVMIN
=<RXLEVMIN>][,HOMARGINPBGT=<HOMARGINPBGT>][,HOMA
RGINRXLEV=<HOMARGINRXLEV>][,HOMARGINRXQUAL=<HOM
ARGINRXQUAL>][,NCELLLAYER=<NCELLLAYER>][,REPPRIOCS=
<REPPRIOCS>][,REPPRIOPS=<REPPRIOPS>][,MAXFORCEHODIF

Confidential and Proprietary Information of ZTE CORPORATION

103

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

F=<MAXFORCEHODIFF>][,HOFORCERESTHS=<HOFORCERESTH
S>][,ISRELATEDCELL=<ISRELATEDCELL>][,ISHOFORCENCELL=
<ISHOFORCENCELL>];
Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Reselect and Handover


Cell ID

Int

USERLABEL

User Label

String

HOPRIORITY

Cell handover priority

Int

MSTXPWRMAX

MS Max Power Level

Int

10

RXLEVMIN

Min reception strength


level

Int

11

HOMARGINPBGT

PBGT min handover


threshold

Int

12

HOMARGINRXLEV

Strength handover
min threshold

Int

13

HOMARGINRXQUAL

Min threshold of
quality handover

Int

14

NCELLLAYER

Adjacent cell layer

Enumer
ation

REPPRIOCS

Priority of
measurement report
submitted within
adjacent cell (CS)

Enumer
ation

16

REPPRIOPS

Priority of
measurement report
submitted within
adjacent cell (PS)

Enumer
ation

17

MAXFORCEHODIFF

Max level offset for


forcible migration
handover

Int

18

HOFORCERESTHS

Migration reservation
resource threshold

Int

19

ISRELATEDCELL

Related cell or not

Int

20

ISHOFORCENCELL

Whether this adjacent


cell is forcible
migration cell

Int

15

104

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Enumeration
Description

Default

Instance
Count

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~32

1-1

0~40

1-1

0~7

1-1

0~31

1-1

10

0~63

1-1

11

0~48

1-1

12

0~48

1-1

13

0~48

1-1

14

0~3

NCELLLAYE
R_1

1-1

15

0~1

REPPRIOCS
_0

1-1

16

0~1

REPPRIOCS
_0

1-1

17

0~48

1-1

18

0~100

1-1

19

0~1

1-1

20

0~1

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:
Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

Layer information of adjacent cell is shown as follows:

Confidential and Proprietary Information of ZTE CORPORATION

105

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Example

Macro Name

Meaning

NCELLLAYER_0

Undefined

NCELLLAYER_1

At same layer as this cell

NCELLLAYER_2

Is upper layer of this cell

NCELLLAYER_3

Is lower layer of this cell

SET
HORS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1,USERLABEL="0",HOPRIORITY=0,MSTXPWRMAX=0,RX
LEVMIN=0,HOMARGINPBGT=0,HOMARGINRXLEV=0,HOMARGIN
RXQUAL=0,NCELLLAYER=NCELLLAYER_1,REPPRIOCS=REPPRIO
CS_0,REPPRIOPS=REPPRIOCS_0,MAXFORCEHODIFF=0,HOFORC
ERESTHS=0,ISRELATEDCELL=0,ISHOFORCENCELL=0;

Create Adjacent Cell Interference


Prompt

ADD INTF

Format

ADD
INTF:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,BS
CID=<BSCID>,SITEID=<SITEID>,BTSID=<BTSID>,ACID=<AC
ID>[,USERLABEL=<USERLABEL>],RELATIONDN=<RELATIONDN
>;

Input
Parameters

106

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Interference Cell ID

Int

USERLABEL

User Label

String

RELATIONDN

Related Cell ID

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Default

Instance
Count

Chapter 2 - Single Command Processing

Output
Parameters

No.

Range

1~6

0~40

0~512

Default

Instance
Count
1-1

""

1-1
1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Example

ADD
INTF:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1
,ACID=1,USERLABEL="",RELATIONDN="0";

Remarks

Dn format in relevant cell:


RELATIONDN="SITEID=1,BTSID=1";RELATIONDN="GERANECEL
LID=111";RELATIONDN="EC3GID=111"

Delete Adjacent Cell Interference


Prompt

DEL INTF

Format

DEL
INTF:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][
,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,AC
ID=<ACID>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Interference Cell ID

Int

No.

Range

1~4095

Default

Instance
Count
1-1

Confidential and Proprietary Information of ZTE CORPORATION

107

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

Default

Instance
Count

No.

Range

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~6

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL
INTF:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1
,ACID=1;

Display Adjacent Cell Interference


Prompt

SHW INTF

Format

SHW
INTF:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>][
,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,AC
ID=<ACID>][,PARAMS=<PARAMS>];

Input
Parameters

108

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

Interference Cell ID

Int

PARAMS

Parameter List

String

No.

Range

Default

1~4095

Confidential and Proprietary Information of ZTE CORPORATION

Instance
Count
1-1

Chapter 2 - Single Command Processing

Output
Parameters

Example

Default

Instance
Count

No.

Range

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~6

1-1

0~1000

""

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

10

INFO

Complex

Query Result

1-10000

SHW
INTF:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=1
,ACID=1,PARAMS=" ";

Create 3G Adjacent Cell Handover


Prompt

ADD 3GHO

Format

ADD
3GHO:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,BS
CID=<BSCID>,SITEID=<SITEID>,BTSID=<BTSID>,ACID=<AC
ID>[,USERLABEL=<USERLABEL>],RSCPOFFSET=<RSCPOFFSET
>,ECNOOFFSET=<ECNOOFFSET>,REPPRIOCS=<REPPRIOCS>,R
ELATIONDN=<RELATIONDN>;

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN Handover
Cell ID

Int

USERLABEL

User Label

String

Confidential and Proprietary Information of ZTE CORPORATION

109

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Enumeration
Description

Example

110

No.

Name

Notes

Type

RSCPOFFSET

RSCP Offset

Int

ECNOOFFSET

Ec/No Offset

Int

10

REPPRIOCS

Priority of
measurement
report submitted
within adjacent cell

Enumeratio
n

11

RELATIONDN

Related DN

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

0~40

""

1-1

0~63

1-1

0~49

1-1

10

0~1

REPPRIOCS_0

1-1

11

0~512

Default

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:
Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

ADD
3GHO:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1,USERLABEL="",RSCPOFFSET=5,ECNOOFFSET=5,REPP
RIOCS=REPPRIOCS_0,RELATIONDN="0";

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Remarks

Dn format in relevant cell:


RELATIONDN="SITEID=1,BTSID=1";RELATIONDN=GERANECEL
LID=111";RELATIONDN="EC3GID=111"
UTRAN cell type must be consistent with actual cell type.

Delete 3G Adjacent Cell Handover


Prompt

DEL 3GHO

Format

DEL
3GHO:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>
][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,
ACID=<ACID>];

Input
Parameters

Output
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN Handover
Cell ID

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

Default

Instance
Count

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Confidential and Proprietary Information of ZTE CORPORATION

111

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Example

DEL
3GHO:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1;

Display 3G Adjacent Cell Handover


Prompt

SHW 3GHO

Format

SHW
3GHO:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>
][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,
ACID=<ACID>][,PARAMS=<PARAMS>];

Input
Parameters

Output
Parameters

112

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN Handover
Cell ID

Int

PARAMS

Parameter List

String

No.

Range

Default

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

0~1000

""

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

23

INFO

Complex

Query Result

1-10000

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Example

SHW
3GHO:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1,PARAMS=" ";

Modify 3G Adjacent Cell Handover


Prompt

SET 3GHO

Format

SET
3GHO:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>
][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,
ACID=<ACID>][,USERLABEL=<USERLABEL>][,RSCPOFFSET=<
RSCPOFFSET>][,ECNOOFFSET=<ECNOOFFSET>][,REPPRIOCS=
<REPPRIOCS>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN Handover Cell ID

Int

USERLABEL

User Label

String

RSCPOFFSET

RSCP offset while


handover to this UTRAN
adjacent cell

Int

ECNOOFFSET

Ec/No offset while


handover to this UTRAN
adjacent cell

Int

10

REPPRIOCS

Priority of measurement
report submitted within
adjacent cell

Enumerat
ion

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

Default

Instance
Count

Confidential and Proprietary Information of ZTE CORPORATION

113

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Enumeration
Description

Example

Default

Instance
Count

No.

Range

0~40

1-1

0~63

1-1

0~49

1-1

10

0~1

REPPRIOC
S_0

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:
Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

SET
3GHO:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1,USERLABEL="0",RSCPOFFSET=0,ECNOOFFSET=0,REP
PRIOCS=REPPRIOCS_0;

Create 3G Adjacent Cell Reselection


Prompt

ADD 3GRS

Format

ADD
3GRS:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,BS
CID=<BSCID>,SITEID=<SITEID>,BTSID=<BTSID>,ACID=<AC
ID>[,USERLABEL=<USERLABEL>],REPPRIOPS=<REPPRIOPS>,R
ELATIONDN=<RELATIONDN>;

Input
Parameters

114

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Output
Parameters

Enumeration
Description

Example

No.

Name

Notes

Type

BTSID

Cell ID

Int

ACID

UTRAN Reselect
Cell ID

Int

USERLABEL

User Label

String

REPPRIOPS

Priority of
measurement
report submitted
within adjacent cell

Enumeratio
n

RELATIONDN

Related DN

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

0~40

""

1-1

0~1

REPPRIOCS_0

1-1

0~512

Default

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:
Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

ADD
3GRS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1,USERLABEL="",REPPRIOPS=REPPRIOCS_0,RELATION
DN="0";

Confidential and Proprietary Information of ZTE CORPORATION

115

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Remarks

Dn format in relevant cell:


RELATIONDN="SITEID=1,BTSID=1";RELATIONDN=GERANECEL
LID=111";RELATIONDN="EC3GID=111"
UTRAN cell type must be consistent with actual cell type.

Delete 3G Adjacent Cell Reselection


Prompt

DEL 3GRS

Format

DEL
3GRS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>]
[,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,A
CID=<ACID>];

Input
Parameters

Output
Parameters

116

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN Reselect
Cell ID

Int

Default

Instance
Count

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Example

DEL
3GRS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1;

Display 3G Adjacent Cell Reselection


Prompt

SHW 3GRS

Format

SHW
3GRS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>]
[,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,A
CID=<ACID>][,PARAMS=<PARAMS>];

Input
Parameters

Output
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN Reselect
Cell ID

Int

PARAMS

Parameter List

String

No.

Range

Default

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

0~1000

""

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

22

INFO

Complex

Query Result

1-10000

Confidential and Proprietary Information of ZTE CORPORATION

117

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Example

SHW
3GRS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1,PARAMS=" ";

Modify 3G Adjacent Cell Reselection


Prompt

SET 3GRS

Format

SET
3GRS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETID>]
[,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>][,A
CID=<ACID>][,USERLABEL=<USERLABEL>][,REPPRIOPS=<RE
PPRIOPS>];

Input
Parameters

118

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN Reselect
Cell ID

Int

USERLABEL

User Label

String

REPPRIOPS

Priority of
measurement
report submitted
within adjacent cell

Enumeratio
n

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

0~40

1-1

0~1

Confidential and Proprietary Information of ZTE CORPORATION

Default

REPPRIOCS_0

Instance
Count

1-1

Chapter 2 - Single Command Processing

Output
Parameters

Enumeration
Description

Example

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:
Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

SET
3GRS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSID=
1,ACID=1,USERLABEL="0",REPPRIOPS=REPPRIOCS_0;

Create UTRAN cell to control adjacent cell


reselection and handover
Prompt

ADD 3GHORS

Format

ADD
3GHORS:SUBNETID=<SUBNETID>,CONFSETID=<CONFSETID>,
BSCID=<BSCID>,SITEID=<SITEID>,BTSID=<BTSID>,ACID=<
ACID>[,USERLABEL=<USERLABEL>][,RSCPOFFSET=<RSCPOFF
SET>][,ECNOOFFSET=<ECNOOFFSET>][,REPPRIOCS=<REPPRI
OCS>][,REPPRIOPS=<REPPRIOPS>],RELATIONDN=<RELATION
DN>;

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN handover
and Reselect Cell ID

Int

USERLABEL

User Label

String

RSCPOFFSET

RSCP offset while


handover to this
UTRAN adjacent

Int

Confidential and Proprietary Information of ZTE CORPORATION

119

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

No.

Name

Notes

Type

cell

ECNOOFFSET

Ec/No offset while


handover to this
UTRAN adjacent
cell

Int

REPPRIOCS

Priority of
measurement
report submitted
within adjacent cell
(CS)

Enumeratio
n

11

REPPRIOPS

Priority of
measurement
report submitted
within adjacent cell
(PS)

Enumeratio
n

12

RELATIONDN

Related DN

String

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

0~40

""

1-1

0~63

1-1

0~49

1-1

10

0~1

REPPRIOCS_0

1-1

11

0~1

REPPRIOCS_0

1-1

12

0~512

10

Output
Parameters

Enumeration
Description

120

Default

Instance
Count

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

Example

ADD
3GHORS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSI
D=1,ACID=1,USERLABEL="",RSCPOFFSET=5,ECNOOFFSET=5,R
EPPRIOCS=REPPRIOCS_0,REPPRIOPS=REPPRIOCS_0,RELATION
DN="0";

Remarks

Dn format in relevant cell:


RELATIONDN="SITEID=1,BTSID=1";RELATIONDN=GERANECEL
LID=111";RELATIONDN="EC3GID=111"
UTRAN cell type must be consistent with actual cell type.

Delete UTRAN cell to control adjacent cell


reselection and handover
Prompt

DEL 3GHORS

Format

DEL
3GHORS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETI
D>][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>
][,ACID=<ACID>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN handover and


Reselect Cell ID

Int

No.

Range

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

Default

Instance
Count

Confidential and Proprietary Information of ZTE CORPORATION

121

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Output
Parameters

Example

No.

Range

1~64

Default

Instance
Count
1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

DEL
3GHORS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSI
D=1,ACID=1;

Display UTRAN cell to control adjacent cell


reselection and handover
Prompt

SHW 3GHORS

Format

SHW
3GHORS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETI
D>][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>
][,ACID=<ACID>][,PARAMS=<PARAMS>];

Input
Parameters

122

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN Reselect
Cell ID

Int

PARAMS

Parameter List

String

No.

Range

Default

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

Confidential and Proprietary Information of ZTE CORPORATION

Instance
Count

Chapter 2 - Single Command Processing

Output
Parameters

Example

Default

Instance
Count

No.

Range

1~1536

1-1

1~24

1-1

1~64

1-1

0~1000

""

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

25

INFO

Complex

Query Result

1-10000

SHW
3GHORS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSI
D=1,ACID=1,PARAMS=" ";

Modify UTRAN cell to control adjacent cell


reselection and handover
Prompt

SET 3GHORS

Format

SET
3GHORS:[SUBNETID=<SUBNETID>][,CONFSETID=<CONFSETI
D>][,BSCID=<BSCID>][,SITEID=<SITEID>][,BTSID=<BTSID>
][,ACID=<ACID>][,USERLABEL=<USERLABEL>][,RSCPOFFSET
=<RSCPOFFSET>][,ECNOOFFSET=<ECNOOFFSET>][,REPPRIOC
S=<REPPRIOCS>][,REPPRIOPS=<REPPRIOPS>];

Input
Parameters

Description of input parameters is as follows:

No.

Name

Notes

Type

SUBNETID

Subnet ID

Int

CONFSETID

Configure Set ID

Int

BSCID

BSC ID

Int

SITEID

BS ID

Int

BTSID

Cell ID

Int

ACID

UTRAN handover and


Reselect Cell ID

Int

USERLABEL

User Label

String

RSCPOFFSET

RSCP offset while

Int

Confidential and Proprietary Information of ZTE CORPORATION

123

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

No.

Name

Notes

Type

handover to this UTRAN


adjacent cell

Output
Parameters

Enumeration
Description

124

ECNOOFFSET

Ec/No offset while


handover to this UTRAN
adjacent cell

Int

10

REPPRIOCS

Priority of measurement
report submitted within
adjacent cell (CS)

Enumerati
on

11

REPPRIOPS

Priority of measurement
report submitted within
adjacent cell (PS)

Enumerati
on

No.

Range

Default

Instance
Count

1~4095

1-1

0~2147483647

1-1

1~4095

1-1

1~1536

1-1

1~24

1-1

1~64

1-1

0~40

1-1

0~63

1-1

0~49

1-1

10

0~1

REPPRIOCS_0

1-1

11

0~1

REPPRIOCS_0

1-1

Description of output parameters is as follows:

No.

Name

Type

Notes

Instance
Count

DETAIL

String

Details

1-1

Priority information submitted by measurement report is shown


as follows:

Macro Name

Meaning

REPPRIOCS_0

REPPRIOCS_1

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 - Single Command Processing

Example

SET
3GHORS:SUBNETID=1,CONFSETID=0,BSCID=1,SITEID=1,BTSI
D=1,ACID=1,USERLABEL="0",RSCPOFFSET=0,ECNOOFFSET=0,
REPPRIOCS=REPPRIOCS_0,REPPRIOPS=REPPRIOCS_0;

Confidential and Proprietary Information of ZTE CORPORATION

125

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

This page is intentionally blank.

126

Confidential and Proprietary Information of ZTE CORPORATION

Appendix

Abbreviations
Abbreviation

Full Spelling Name

B
BSC

Base Station Controller

BTS

Base Transceiver Station

C
CPU

Central Processing Unit

CLKG

Clock Generator

D
DRTB

Dual Rate Transcoder Board

DTB

Digital Trunk Board

F
FAQ

Frequently Asked Questions

G
GLI

Gigabit Line Interface

GIPB

Gb Interface Processing board

H
HW

High Way line

I
IP

Internet Protocol

ISMG

Infrastructure Server for O&M for GSM

L
LAPD

Link Access Protocol of D-Channel

O
OMP

Operation Main Processor

S
SMTP

Simple Message Transfer Protocol

SPB

Signaling Processing Board

Confidential and Proprietary Information of ZTE CORPORATION

127

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

Abbreviation

Full Spelling Name

T
TMN

Telecommunication Management Network

128

UIMC

Universal Interface Module for Control plane (BCTC


or BPSN)

UIMU

Universal Interface Module for User plane

UPPB

User Plane Processing Board

Confidential and Proprietary Information of ZTE CORPORATION

Appendix

Figures
Figure 1 - Select MML Terminal ............................................5
Figure 2 - MML Terminal Interface ........................................6
Figure 3 - Configure Preferences 1 ........................................7
Figure 4 - Configure Preferences 2 ........................................7
Figure 5 - Configure Preferences 3 ........................................8
Figure 6 - Input by Command Prompt Box ........................... 10
Figure 7 - Select Command / Fill in Parameters..................... 11

Confidential and Proprietary Information of ZTE CORPORATION

129

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

This page is intentionally blank.

130

Confidential and Proprietary Information of ZTE CORPORATION

Tables
Table 1 - Chapter Summary ..................................................i
Table 2 - Typographical Conventions ..................................... ii
Table 3 - Mouse Operation Conventions ................................ iii
Table 4 - Command Compilation ...........................................3

Confidential and Proprietary Information of ZTE CORPORATION

131

ZXG10 ISMG (V6.10) Operation & Maintenance Center Command Manual

This page is intentionally blank.

132

Confidential and Proprietary Information of ZTE CORPORATION

Index
Cell Configuration................ 25
Configure cell object ............ 46
Create 3G Adjacent Cell
Handover ..................... 109
Create 3G Adjacent Cell
Reselection................... 114
Create Adjacent Cell Handover
.................................... 87
Create Adjacent Cell
Interference ................. 106
Create Adjacent Cell
Reselection..................... 94
Create Adjacent Cell
Reselection and Handover. 99
Create GERAN External Cell .. 12
Create Hopping System ....... 54
Create UTRAN cell to control
adjacent cell reselection and
handover ..................... 119
Create UTRAN External Cell .. 19
Delete 3G Adjacent Cell
Handover ..................... 111
Delete 3G Adjacent Cell
Reselection................... 116
Delete Adjacent Cell Handover
.................................... 90
Delete Adjacent Cell
Interference ................. 107
Delete Adjacent Cell Reselection
.................................... 95
Delete Adjacent Cell Reselection
and Handover ............... 101
Delete Cell Command .......... 25
Delete GERAN External Cell .. 15
Delete Hopping System........ 55
Delete transceiver ............... 46
Delete UTRAN cell to control
adjacent cell reselection and
handover ..................... 121
Delete UTRAN External Cell .. 22
Display 3G Adjacent Cell
Handover ..................... 112
Display 3G Adjacent Cell
Reselection................... 117
Display Adjacent Cell Handover
.................................... 90

Display Adjacent Cell


Interference ................. 108
Display Adjacent Cell
Reselection .................... 96
Display Adjacent Cell
Reselection and Handover
.................................. 102
Display Channel.................. 50
Display GERAN External Cell . 15
Display Handover Control..... 65
Display Hopping System ...... 56
Display Power Control.......... 59
Display transceiver.............. 47
Display UTRAN Cell Control .. 78
Display UTRAN Cell Handover
Control .......................... 74
Display UTRAN cell to control
adjacent cell reselection and
handover ..................... 122
Display UTRAN External Cell . 22
External Cell Configuration ... 12
Modify 3G Adjacent Cell
Handover ..................... 113
Modify 3G Adjacent Cell
Reselection .................. 118
Modify Adjacent Cell Handover
.................................... 91
Modify Adjacent Cell
Reselection .................... 97
Modify Cell Command .......... 27
Modify Channel................... 51
Modify GERAN External Cell .. 16
Modify Handover Control...... 66
Modify Hopping System ....... 57
Modify Power Control........... 60
Modify transceiver .............. 48
Modify UTRAN Cell Control ... 79
Modify UTRAN Cell Handover
Control .......................... 75
Modify UTRAN cell to control
adjacent cell reselection and
handover ..................... 123
Modify UTRAN External Cell .. 23
Show Cell Command ........... 26

Confidential and Proprietary Information of ZTE CORPORATION

133

Вам также может понравиться