Compressor Model
Cylinder S/N CCDriver
Packager
Date Packager Shipped
Serviceman
Location
Field Telephone No.
Frame Oil - Make/Grade
Cylinder Oil - Make/Grade
C-
C-
YES
NO
Face
Rim
REV
PAGE 1
DESCRIPTION
inches (mm)
Rev 5: ECN8236
Rev 4: ECN6887
Rev 3: ECN6333
ER-10.4.0
Serial No. F-
YES
NO
12. Have the piston end clearances been checked with feeler gauges?
Throw #1
#2
#3
#4
#5
#6 - Record below.
CE
HE
13. Has the crankcase been filled with oil to the proper level?
14. Has proper oil been installed if extreme ambient conditions
exist or special gases are compressed?
15. Is the compressor crankcase oil level control working and
set at the proper level?
16. Is the crankcase oil supply isolation valve open?
17. Does the crankcase low level shutdown work?
18. Has the recommended oil filter elements been installed?
19. Are the oil filter elements and all lube oil piping primed with oil?
20. Is the low oil pressure shutdown installed and tubed correctly
to the downstream side of the oil filter?
21. Does the low oil pressure shutdown work?
22. Oil cooler? Compressor inlet oil temp. is 190BF (88BC) max.
23. Is the crankcase oil temperature shutdown installed, set
And working?
24. If oil is cooled, is there a temperature control valve?
25. Is the crankcase breather element clean?
26. Is the force feed lubricator box filled with oil?
27. Is the force feed lubrication system primed?
28. Is the force feed lubrication system no flow shutdown
installed and working?
29. Is the force feed blow out assembly installed? Check rupture
disc for color? Purple is standard = 3250 PSIG (22 400 kPa).
30. Has the lubricator instruction plate or Technical Manual Cylinder
Lubrication Sheet been checked for proper lube feed rate?
31. Is there a working vibration shutdown mounted on the
compressor?
32. Are the primary and secondary packing vents and distance
piece vents open, and when necessary, tubed off of the skid or
out of the building?
33. Is there some method of suction control?
34. Are the suction pressure, interstage pressure and discharge
pressure shutdowns set and working?
35. Are the safety relief valves installed and working to protect
cylinders and piping for each stage of compression?
PAGE 2
REV 5
ER-10.4.0
Serial No. F-
YES
NO
YES
NO
PAGE 3
REV 5
ER-10.4.0