Академический Документы
Профессиональный Документы
Культура Документы
omega.co.uk
m
5m
m
6m
4
3.4
TM
Volume
1
mm
TABLE OF CONTENTS
Sensors for
Hygienic Applications
1
Thermocouple Sensors
and Temperature Probes
2
RTD Temperature
Sensors and Transmitters
3
Wireless Sensors
and Transmitters
4 to 5
Strain Gauges
and Load Cells
6 to 7
W ELCOME TO OM EGA!
Exceeding Your Expectations
Welcome to our New Product Showcase
detailing some of the latest developments
in process measurement and control.
This brochure represents just a small
selection of our range. You can find over
100,000 products on-line at
omega.co.uk or through our range of
FREE hardbound handbooks and
encyclopedias.
For over four decades our handbooks
have served as valuable reference tools
for engineers around the world. Our
people, facilities and superior customer
service go well beyond the OMEGATM
Handbooks. Since our inception in 1962,
OMEGA has grown from manufacturing a
single line of thermocouples to an established
global leader in the technical marketplace, offering
state-of-the-art products for measurement and control of
temperature, humidity, pressure, strain, force, flow, level, pH and conductivity.
OMEGA also provides customers with a complete line of data acquisition, electric
heaters and custom engineered products. It is our commitment to quality
instrumentation and exceptional customer service that has remained the
cornerstone of our success. OMEGAs priority is clear. Our facilities exist to
facilitate solutions to your needs.
Easy to Order
Phone
Pressure Transducers
8
Flow Meters
and Transmitters
9
Ordering is as easy as picking up the phone and dialling our FREE PHONE or
International numbers:
INTERNATIONAL
One of our sales representatives will assist you with product selection and
placing your order. If you need further technical assistance, we have a team of
engineers available to help you solve your application problems.
Internet
General Instrumentation
10
Infrared Temperature
Meters and Transmitters
11
Automation and
Control Products
12
Data Acquisition
Systems and Loggers
13
COPYRIGHT 2010 OMEGA ENGINEERING, LTD. ALL RIGHTS RESERVED.
Our on-line shop has over 100,000 products. Use your web browser to go to
omega.co.uk. Once your order is placed, it is reviewed and delivery
confirmation is
promptly e-mailed
to you.
Fast Delivery
From our European
manufacturing
headquarters in the
UK we are ideally
placed to serve
customers
throughout Europe,
with overnight
service available for
those who need next
day delivery.
Notice of Intellectual Property Rights
The OMEGA Handbook Series is based upon original intellectual property rights that were created and developed by OMEGA. These rights
are protected under applicable copyrights, trade dress and trademarks laws. The distinctive, composite appearance of these Handbooks
is uniquely identified with OMEGA, including graphics, product identifying pings, paging/section highlights, and layout style. The front, back
and inside front cover arrangement is the subject of a U.S. Patent Pending.
Pricing: The prices listed are those in effect at the time of the publication and are subject to change without notice. Contact OMEGAs
sales department for current prices.
omega.co.uk
e-mail: info@omega.co.uk
nd
in CIP a ses
e
s
U
r
o
s
F
c Proce
Hygieni
UWRTD-NB9W Series
Starts at
Starts at
80
Integral
cable
with nylon
cable clamp.
10 mm diameter.
5 mm diameter.
178
UWRTD-NB9W1PT316-M60-100,
178.
Thermowell,
11/2-S-260UM60-316SS,
84.
PRS-3-100-A-H-M75-D1-CB-3M, 101.
Visit omega.co.uk/PRS-3-101
Visit omega.co.uk/UWRTD-NB9W
M12
connector.
PRS-3-100-A-S-M100-D1-M12, 74.
PRS-M12 Series
Starts at
74
Twist-lock
connector.
All Models
316L SS 112"
Tri-Clamp
cap standard.
6 mm diameter.
392
Visit omega.co.uk/PRS-M12
Shop Online at
NB12-CP
Starts at
65
HPP4-1-KI-1000, 140.
HPP Series
Starts at
NB12-CP-K-M12U-300, 65.
UK
98
UK
HH501DK,
4-channel
thermometer,
70.
UK
1 or 4 Sensing Points
Individual Thermocouple
Plugs, Labelled for Easy
Identificaion
Rugged Aluminium
T-Handle and Needle
Point Allowing Easy
Insertion into Semi-Solid
Materials
1 and 1.5 m Standard
Lengths
CP-MF, 9,
removable flange.
UK
al
Individule Plugs
coup
Thermo labeled
are
Ceramic Sheath.
Inside the IP67
rated industrial
protection head.
Visit omega.co.uk/HPP
Visit omega.co.uk/NB12-CP
TCS-H-CB-120 Series
101
Integral cable
with nylon
cable clamp.
TCS-TUS-NB9W Series
Starts at
64
TCS-TU-H-M100-D1-CB-3M, 101.
TCS-TU-H-M75-D1-NB9W, 84.
10 mm diameter.
10 mm diameter.
5 mm diameter.
Visit omega.co.uk/TCS-H-CB
Visit omega.co.uk/TCS-S-NB9W
5 mm diameter.
*PATENTED
Covered by U.S. and International
Patents and pending applications
UWRTD-S-2,
184.
184
HSRTD-3-100-A-1M, 30.
Starts at
30
UK
UK
Industry Standard
M12 Connection with
Waterproof White
Polypropylene
Housing
Free Software
Converts Your PC
into a Multi-Channel
Chart Recorder
or Data Logger
Interface up to 48
Wireless Transmitters
with One Receiver
Nickel-plated
copper,
PFA insulated
and jacketed
cable.
Nominal
diameter
2.1 mm.
Element sealed in
first 3 mm of sensor.
Includes mounting
bracket and
sensor cable.
Visit omega.co.uk/UWRTD-S-2
Visit omega.co.uk/HSRTD
F2020
F2020, 0.67p,
shown larger
than actual
size.
Starts at
67
EWSE Series
Each
Multiples of 100 pieces
Connection
wires.
Starts at
85
UK
UK
Glass
coating
over wire
bonds.
Visit omega.co.uk/F2020
EWSE-Pt100,
85.
Visit omega.co.uk/EWSE
All products shown smaller than actual size unless stated otherwise
Shop Online at
UWIR-2-NEMA, 191.
MWTC Series
53
Starts at
Measurement Range
-18C to 538C
Adjustable Emissivity
from 0.10 to 1.0
Free Software Converts
Your PC into a MultiChannel Chart Recorder
or Data Logger
Low Power Operation
and Sleep Mode for
Long Battery Life
connector, 53.
Starts at
UWIR-2-NEMA
191
IR sensor head.
OS100-WC,
water cooling
jacket, 117.
OS100-LS,
laser sighting,
117.
Available in Types
J, K, T, E, R, S, B, C
or N Thermocouple
Calibration
Transmits Data up to
90 m Away
Model MWTC-REC1 or
MWTC-REC5 Receivers
Work with up to 48
Wireless Remote
Transmitters
Low Power Operation
and Sleep Mode for
Extended Battery Life
Free 1 m type K
thermocouple
included with
J, K, T and E
models.
MWTC-REC1
USB receiver,
78.
Visit omega.co.uk/MWTC
Visit omega.co.uk/UWIR
RTD-TO-WIRELESS CONNECTOR/CONVERTER
FOR Pt100 SENSORS
The Smart Connector TM
UWPC-2-NEMA, 178.
UWRTD-2, 90.
UWPC-2-NEMA
178
TA4F mating
connector, 6.70.
*PATENTED
Convert Process
Signal to Wireless
Accepts 0 to 1V, 0 to 5V,
0 to 10V and 4 to 20 mA
Signals
Industrial IP65
(NEMA 4X) Enclosure
Free Software Included
for Data Logging,
Monitoring and
Recording
Low Power Operation
and Sleep Mode for
Long Battery Life
Visit omega.co.uk/UWPC
UWRTD Series
Starts at
PXM209-010G5V,
Pressure sensor,
115.
PSU-24VUniversal,
24.
90
Interface up to 48
Different Wireless
Connectors with
One Receiver
Free Software for
Real-Time Display,
Multi-Channel Chart
Low Power Operation
and Sleep Mode for
Long Battery Life
Visit omega.co.uk/UWRTD
*PATENTED
Covered by U.S. and International
Patents and pending applications
UWTC-REC4
Starts at
184
Works with up to 48
Wireless Transmitters
Four 0 to 5 Vdc,
0 to 10 Vdc or
4 to 20 mA Analogue
outputs
Interface Directly to
PLCs, Chart
Recorders and
Data Loggers
Built-in Programmable
Alarms for Each
Channel
RAIL-35-1,
6.70.
265
Wi833-U, 265.
Wireless Inputs:
Thermocouple,
RTD, Infrared,
Temperature
Simple to Configure
Embedded Ethernet
2 Alarm Outputs:
Solid State Relays
(SSRs), DC Pulse,
Mechanical Relays,
Analogue Voltage
and Current
Works with
UWTC-2,
wireless
thermocouple
connector,
90.
Visit omega.co.uk/UWTC-REC4
Visit omega.co.uk/Wi8
UWRH-2
UWRH-2, 111.
Visit omega.co.uk/UWRTD-2
Starts at
111
UWRTD-2-NEMA,
117.
Measures Temperature
and Relative Humidity in
One Unit
Free Software Converts
Your PC into a MultiChannel Chart Recorder
or Data Logger
Works with All UWTC
Wireless Receivers and
Transceivers
Low Power Operation
and Sleep Mode for
Long Battery Life
Multiple Measurements
and Battery Status
Transmitted in Real-Time
IP65 NEMA-4X
Weather Resistant
Enclosure
Low Power Operation
and Sleep Mode for Long
Battery Life
Works with Every OMEGA
UWTC Series Receiver,
WiSeriesMeter/Controller/
Scanner and DIN Rail
Receiver
Operate up to 48 Different
Wireless Transmitters with
One Receiver
Pt100 Probe,
24.
UWRTD-2-NEMA
Starts at
117
Visit omega.co.uk/UWRH
Shop Online at
SGD-1.5/120-LY41, 30
( pack of 10 ).
3.4 mm
SGD Series
SGT Series
Starts at
Starts at
30
4.7 mm
3.5
5.5 mm
mm
25
13
8.8
7.0 mm
mm
Pack of 5
Pack of 10
Economically Priced
per Pack of 10
Linear Gauges for Static
and Dynamic Applications
Small Bending Radius
Temperature Range
-75 to 200C
Clear Alignment Marks
Affix with Cold or
Hot Cure Adhesives
Economically Priced
per Pack of 5
Shear Gauges for Torque
or Shear Applications
Rugged, High Reliability
Temperature Range
-75 to 95C
Clear Alignment Marks
Affix with Cold or
Hot Cure Adhesives
Visit omega.co.uk/SGD
Visit omega.co.uk/SGT
LCM703-10,
198, shown
actual size.
LCMKD Series
Starts at
369
LCM703-500, 265.
5-Point Calibration
Certificate Included
Low Profile
High Linearity of 0.1%
Rugged Industrial Design
Visit omega.co.uk/LCMKD
Visit omega.co.uk/LCM703
LCM703 Series
Starts at
198
All products shown larger than actual size unless stated otherwise
6
*PATENTED
Covered by U.S. and International
Patents and pending applications
Gauge Length
Transition
STRAIN GAUGE
RESISTANCE
Gauge Length
Number of Gauges in Gauge Pattern
Grid Resistance
Strain-Sensitive Alloy
Carrier Material
Gauge Width
Solder Tab Type
Configuration of Solder Tab
Availability
GAUGE FACTOR
(STRAIN SENSITIVITY)
STRAIN GAUGE
DIMENSIONS
The active grid length, in the case of foil
gauges, is the net grid length without the
tabs, and includes the return loops of
the wire gauges.
Carrier dimensions are designed by
OMEGA for optimum function of the
strain gauge.
Shop Online at
REFERENCE TEMPERATURE
The reference temperature is the
ambient temperature for which the
technical data concerning a strain
gauge are valid, unless temperature
ranges are given.
The technical data quoted for strain
gauges are based on a reference
temperature of 23C.
TEMPERATURE
CHARACTERISTICS
Temperature-dependent changes in
specific strain gauge grid resistance
occur in the applied gauge owing to the
linear thermal expansion of the grid and
specimen materials. These resistance
changes appear to be mechanical strain
in the specimen. The representation of
apparent strain as a function of
temperature is called the temperature
characteristic of the strain gauge
application.
In order to keep apparent strain through
temperature changes as small as
possible, each strain gauge is matched
during production to a certain linear
thermal expansion coefficient. OMEGA
offers strain gauges with temperature
characteristics matched to ferritic steel
and aluminium.
SERVICE TEMPERATURE
RANGE
The service temperature range is the
range of ambient temperature wherein
the use of a strain gauge is possible
without permanent change in the
measurement properties. Service
temperature ranges are different,
whether static or dynamic values are
to be sensed.
MAXIMUM PERMITTED
RMS BRIDGE ENERGISING
VOLTAGE
The maximum values quoted are
permitted only for appropriate
application on materials with good
conduction (e.g., steel of sufficient
thickness) if room temperature is not
exceeded. In other cases, temperature
rise in the measuring grid area may lead
to measurement error. Measurement on
plastics and other materials with bad
thermal conduction requires reduction
of the energising voltage or of the duty
cycle (pulsed operation).
PRESSURE TRANSDUCERS
MM SERIES PRESSURE TRANSDUCERS
Configure Your Own Custom Designed Trandsucer!
Typical delivery from Next Day to 2 Weeks*!
MMG050VP5C0T3A5,
235, features 50 psi mV
output, 0.4% accuracy,
cable termination.
MM Series
Starts at
235
MMDWU015VP5C1T3A5,
436, features 15 psid,
mV output, 0.4% accuracy,
twist-lock termination.
MMG100C1P5C6T3A5,
278, features 100 psi
4 to 20 mA output,
0.40% accuracy,
mini-DIN termination.
MMG10WVP3C1T2A2,
405, features 0 to 10" in-H2O,
mV output, 0.08% accuracy,
twist-lock termination.
*PATENTED
Covered by U.S. and International
Patents and pending applications
FTB-410A,
840.
FTB-400 Series
Starts at
840
Visit omega.co.uk/WT-200
Portable Bench-Top
Design
Provides Highly
Accurate, Uniform
and Repeatable Air
Flow up to 1000 fpm
Allows for Open
Loop Full Scale
Operation of Fans,
Groups of 2 Fans, or
All 4 Fans at Once
WT-200 Series
3345
Visit omega.co.uk/FTB-400
FMA-4100/4300 Series
FMA1000 units
feature a large,
easy to read
backlit LCD.
FMA1000 Series
Starts at
Starts at
489
23 Selectable
Engineering
Units
High and Low
Gas Flow Alarms
Two Sets of
Programmable
SPDT Relays
with Latching
Feature
Selectable
Analogue
0 to 5 Vdc or
4 to 20 mA
Outputs
446
Measures Air
Velocities up to
50 M/Sec (10,000 fpm)
Measures Air
Temperature up to 120C
250 ms Response Time,
Programmable
up to 2 Seconds
Displays in Velocity
Visit omega.co.uk/FMA-4100
Many versions
avaliable, call
sales for details
Visit omega.co.uk/FMA1000
Shop Online at
HH126,
201.
Starts at
168
Dual K/J/T/E/R/S/N
Input (HH127)
Dual 2, 3 and 4-Wire
RTD Input (HH126)
RTD and Thermocouple
Inputs (HH176)
Large Easy to Read
LCD Display
T1, T2, T1-T2
IR to USB Data
Transfer Output
Connects Directly to
a USB Port on Your
Computer
Free Software Converts
Your PC into a Humidity
and Temperature Meter,
Data Logger or Chart
Recorder
Suited for Wall or
Duct Mounting
RH-USB, 97.
RH-USB
97
Visit omega.co.uk/RH-USB
Visit omega.co.uk/HH120
TM
UV1000-PM with
external speaker,
191.
EIT-W, 131.
UV1000,
160.
t Any
Connec vice to
e
Serial Dt, LAN and
EtherneInternet
the
UV1000/PM
Starts at
160
EIT-W
131
Visit omega.co.uk/EIT-W
*PATENTED
Covered by U.S. and International
Patents and pending applications
OS555A,
570.
Starts at
UWIR-2-NEMA, 191.
570
191
Measurement Range
538C to 2482C
Take Measurements
Through Glass or
Transparent Plastic
Windows
1% Rdg Accuracy
110:1 Field of View
RS232 Communications
Free User Software
Included
Make the
OS555A
wireless with
the optional
WRS232-USB
transceiver, 107.
IR sensor head.
Measurement Range
-18C to 538C
Adjustable Emissivity
from 0.10 to 1.0
Free Software Converts Your PC
into a Multi-Channel Chart Recorder
or Data Logger
One Receiver Works with up to 48 Transmitters
Low Power Operation and Sleep Mode for Long
Battery Life
Visit omega.co.uk/OS555A
Visit omega.co.uk/UWIR
OS4000 Series
OS530E-W9 Series
Starts at
Starts at
1000
198
Visit omega.co.uk/OS4000
Lens probe
assembley sold
separately.
Back view.
TM
*PATENTED
Built-In Wireless
Temperature Measurement
Rugged, High-Performance
Design
The Laser can be Flashing
or Continuous
C/F Switchable
Backlit LCD
Temperature Ranges
200C to 1600C
Very Fast Response
Time of 1 ms
OS530E-W9,
LCD display.
Visit omega.co.uk/OS530E-W9
Shop Online at
11
STM Series
Starts at
279
OCSXL Series
Starts at
298
Visit omega.co.uk/OCSXL
Visit omega.co.uk/STM
SCE-6N604LP, 18.50.
HE359 Series
Starts at
134
Daisy-chaned units,
HE359DAC007,188,
HE359ADC107, 164,
and HE359RTD100, 188.
Side view.
Ideal for
Instruments,
Electrical Controls
and Components
1.5 or 1.9 mm Thick
Carbon Steel,
Depending on its Size
Spot Weld Construction
Suitable for Cleaning-In
-Place (CIP)
Doors Open 180
Visit omega.co.uk/SCE-NLP
SCE-NLP Series
Starts at
1850
*PATENTED
Covered by U.S. and International
Patents and pending applications
PT-104
iTHX-SD Series
399
Starts at
2GB SD memory
card supplied.
265
PT104, comes
with 4 mating
mini DIN
connectors.
Working
View a -line at
Unit On X-SD
/iTH
Visit omega.co.uk/iTHX-SD
Visit omega.co.uk/PT-104
825
OM-EL-USB-2-LCD, 65.
OM-EL-USB-2-LCD
Starts at
65
Measurement Range
0 to 100% RH
Temperature Range
-35C to 80C
USB Interface for Set-Up
and Data Download
Status Indication Via Red
and Green LEDs
OM-EL-USB-2-LCD
Dimensions: mm
126
25.3
4 to 8 Universal Analogue
Inputs (Current, Voltage,
Resistance, Temperature)
Plus 8 Digital Inputs
16 Derived/Calculated
Channels
0.1% Accuracy
Up to 1.8 Million Readings
Software Included
RS-232 Output for Modem
and Wireless Connection
OM-SQ-SOFT-PLUS,
195, optional graphical
tabular format software,
sold seperately.
Visit omega.co.uk/OM-SQ2010
Shop Online at
13
Whats New at
omega.co.uk
TM
or visit www.omega.co.uk