Вы находитесь на странице: 1из 4

Final assessment (End of 8 weeks course)

Name of Candidate:

Course Name: BTS MW I&C

Q 1. Maximum output power of FPMA is


(a) 4w

(b) 9w

(c) 5w

(d) 7w

Q 2. Voltage requirement for Flexi BTS is -48V at temperaturedegree


centigrate
(a) 27

(b) 23

(c) 21

(d) 22

Q 3. Height of HCT & IGB ismm.


(a) 2400 ,1000
(c) 2200, 2000
Q 4. Size of

(b) 2100,2200
(d) 2200,2100

Indoor & outdoor BTS is HU

(a) 38 ,40

(b) 40,36

(c) 36,38

(d) 32,38

Q 5 Torque applied for RPC 7/16 connector is .NM


(a) 22-30
(c)

(b) 24-30

23-28

(d) 27-30

Q 6. Connector kit T55255.02 is for


(a) RG-223
(c) RG-214

(b) RG-216
(d) RG-218

Q 7. For installation of IF cable distance between fastening points


is cm.
(a) 200<x<350
(b) 100<x<150

(b) 150<x<200
(d)120<x<150

Q 8. For ODU DC voltage supply is .volts.


(a) 52 to 60

(b) 48 to 52

(c) 52 to 58

(d) 50 to 55

Q 9. IDU Power consumption is ..W.


(a) <16

(b) >17

(c) <17

(d) >16

Q 10. In Flexi hopper Indoor units every unit supports all radio
transmission capacities
(a) 2*2m - 16*2m

(b)2*2m - 2*16m

(c) 2*4m 4*5m

(d) 2*4m 17*2m

Q 11. Frequency hoppers are available in following frequency bands


(a) 7,13,15,38

(b) 38,8,26,28

(c) 23,26,32,38

(d) 15,18,26,28

Q 12. Severity level three represents


(a) Non functional defect minor
(b) Non functional defect major
(c) Functional major defect
(d) Functional minor defect
Q 13. RF cable labeling

for 4th sector Tx/Rx

(a) 4140

(b) 4110

(c) 4120
Q 14. Label for main Earthing

(d) 4141
25mm square is

(a) 1000

(b) 1001

(b) 1006
Q 15. Label for

feeder is

(d) 4000

support alarms is

(a) 6100

(b) 6200

(c) 6130

(d) 6400

Q 16. TRx output power level depends upon

Q 17. VSWR

Q 18.

(a) BTS configuration

(b)

(c) battery bank

(d) PIU

for a good installation must be


(a) =1.4

(b) <=1.3

(c) >1.3

(d) none of these

Minimum DG rating for a sharing site isKVA


(a) 7.5 KVA
(c) 15 KVA

19

DDF

(b) 10 KVA
(d) 25 KVA

GSM Pole length range is :


(a) 1.5 to 2.5m

(b) 1 to 3m

(c) 2 to 3 m

(d) 2 to 3.5m

Q 20 Distance between BTS & Shelter wall is


(a) 50mm or 500mm

(b) 100mm or 1000mm

(c) 35mm or 350 mm

(d) None of these

Q 21. Size of Earthing cable used for servo grounding is


(a) 35mmsq.

(b) 25mmsq.

(c)16 mmsq.

(d) 15mmsq.

Q 22 Size of sector module is HU.


(a) 3

(b) 2

(c) 5

(d) 1

Q 23. Which are critical alarms


(a) Mains failure

(b) DG fail to start

(c) High Temperature

(d) Low battery charge

Q 24. Bending radius of FXL780(7/8) cable is mm.


(a) 128

(b) 127

(c) 122

(d) 118

Q 25

Tensile strength of AVA 5-50(7/8) is


(a) 249

.. kg.
(b) 127

(c) 122

(d) 159

Q 26. Temperature range for Flexi Edge BTS is .degree centigrate


(a) -34 to +55

(b) -33 to +50

(c) 40 to 43

(d) 33 to 50

Q 27 Size of Nokia Flexi BTS 3HU module is


(a) 133*447*560[mm]
(b) 230*223*117[mm]
(c) 127*133*300[mm]
(d) None of these
Q 28. How much space is recommended between plinth to enable cabling
during wall Installation of Flexi BTS
(a)160mm

(b) 150mm

(c)100mm

(d) 75mm

Q 29. Size of Antenna jumper cable is


(a)

(b)3/8

(c)1/4

(d) 1/16

Q 30. Minimum sector modules required for one sector


(a)1

(b)2

(c) 3