Вы находитесь на странице: 1из 251

PAKISTAN

WATER AND POWER DEVELOPMENT AUTHORITY

ZONE-2
Lahore, Gujranwala, Sialkot, Jhang, Faisalabad, Hafizabad, Sheikhupura,
Nankana sahib, Narowal, Toba Tek Singh, Bhakkar, Sahiwal, Okara,
Pakpattan and Kasur

RATES DIRECTORATE
COORDINATION & MONITORING DIVISION (WATER)
WAPDA HOUSE, LAHORE (Pakistan)
January, 2013

Reproduction in part or whole of this book by an Individual, Department,


Agency, Consultants, Contractor or Firm etc. is strictly prohibited.

Rs 1000/WAPDA

WCSR-2013 (Zone-2)

WAPDA

WCSR-2013 (Zone-2)

SECTION 1
CARRIAGE OF MATERIAL,
LOADING AND UNLOADING

WAPDA

WCSR-2013 (Zone-2)

SECTION 2
EARTHWORK
(EXCAVATION AND EMBANKMENT)

WAPDA

WCSR-2013 (Zone-2)

SECTION 3
DISMANTLING (DEMOLITION)

WAPDA

WCSR-2013 (Zone-2)

SECTION 4
M O R T A R

WAPDA

WCSR-2013 (Zone-2)

SECTION 5
C O N C R E T E

WAPDA

WCSR-2013 (Zone-2)

SECTION 6
BRICK WORK

WAPDA

WCSR-2013 (Zone-2)

SECTION 7
STONE MASONRY

WAPDA

WCSR-2013 (Zone-2)

SECTION 8
R O O F I N G

WAPDA

WCSR-2013 (Zone-2)

SECTION 9
F L O O R I N G

WAPDA

WCSR-2013 (Zone-2)

SECTION 10
SURFACE RENDERING

WAPDA

WCSR-2013 (Zone-2)

SECTION 11
WOOD WORK

WAPDA

WCSR-2013 (Zone-2)

SECTION 12
PAINTING AND VARNISHING

WAPDA

WCSR-2013 (Zone-2)

SECTION 13
WATER SUPPLY AND SANITATION WORKS

WAPDA

WCSR-2013 (Zone-2)

SECTION 14
ROADS AND ROAD STRUCTURES

WAPDA

WCSR-2013 (Zone-2)

SECTION 15
LINING OF CANALS

WAPDA

WCSR-2013 (Zone-2)

SECTION 16
SHEET PILING

WAPDA

WCSR-2013 (Zone-2)

SECTION 17
RIVER TRAINING AND DIVERSION WORK

WAPDA

WCSR-2013 (Zone-2)

SECTION 18
O U T L E T S

WAPDA

WCSR-2013 (Zone-2)

SECTION 19
SINKING OF WELLS

WAPDA

WCSR-2013 (Zone-2)

SECTION 20
MISCELLANEOUS

WAPDA

WCSR-2013 (Zone-2)

SECTION 21
ELECTRIFICATION

WAPDA

WCSR-2013 (Zone-2)

SECTION 22
BASIC RATES OF MATERIAL
FOR CIVIL WORKS

WAPDA

WCSR-2013 (Zone-2)

SECTION 23
BASIC RATES OF MATERIAL
FOR ELECTRIC WORKS

WAPDA

WCSR-2013 (Zone-2)

SECTION 24
BASIC RATES OF LABOUR

WAPDA

WCSR-2013 (Zone-2)

SECTION 25
BASIC RATES OF MACHINERY USAGE

WAPDA

WCSR-2013 (Zone-2)

CONTENTS
Section

1.

Title

Pages

Preface

to

iii

Abbreviation & Symbol...

iv

to

Conversion Factors.

vi

to

viii

CARRIAGE OF MATERIAL, LOADING AND UNLOADING.

1-1

to

1-13

A)

Carriage of Material

1-1

to

1-10

B)

Loading, Unloading and Stacking.

1-11

to

1-13

2.

EARTHWORK (EXCAVATION AND EMBANKMENT).

2-1

to

2-8

3.

DISMANTLING (DEMOLITION)

3-1

to

3-4

4.

MORTAR

4-1

5.

CONCRETE.

5-1

to

5-5

6.

BRICK WORK..

6-1

to

6-5

7.

STONE MASONRY

7-1

to

7-5

8.

ROOFING.

8-1

to

8-5

9.

FLOORING.

9-1

to

9-6

10.

SURFACE RENDERING

10-1

to

10-3

11.

WOOD WORK.

11-1

to

11-7

12.

PAINTING AND VARNISHING.

12-1

to

12-5

13.

WATER SUPPLY AND SANITATION..

13-1

to

13-24

14.

ROAD AND ROAD STRUCTURES..

14-1

to

14-5

15.

LINING OF CANALS...

15-1

to

15-2

16.

SHEET PILING

16-1

17.

RIVER TRAINING AND DIVERSION WORKS..

17-1

to

17-3

18.

OUTLETS.

18-1

to

18-3

19.

SINKING OF WELLS..

19-1

20.

MISCELLANEOUS.

20-1

to

20-24

WAPDA

WCSR-2013 (Zone-2)

Section

Title

21.

ELECTRIFICATION

Pages

21-1

to

21-45

Internal Electrification of Building..

21-1

to

21-40

1. Point Wiring.

21-1

to

21-5

2. Miscellaneous.

21-5

3. Mains and Sub-Mains

21-6

to

21-22

4. Electrical accessories

21-23

to

21-26

5. Boards.

21-26

to

21-27

6. Fittings and Fixtures..

21-27

to

21-28

7. Fans.

21-28

to

21-30

8. Switch Gears..

21-30

to

21-36

21-37

to

21-45

O/H Transmission & Distribution

21-41

to

21-44

22.

BASIC RATES OF MATERIAL FOR CIVIL WORKS.

22-1

to

22-18

23.

BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

23-1

to

23-14

24.

BASIC RATES OF LABOUR..

24-1

to

24-2

25.

BASIC RATES OF MACHINERY USAGE

25-1

to

25-3

A-I

A-II
B)

WAPDA

Internal Electrification of Building.

WCSR-2013 (Zone-2)

PREFACE
1. The cost of a project directly depends on rates and prices of different items and inputs
of a contract, therefore the rates and prices of goods, works and services comprising
composite rates set out in the estimate of a contract must be realistic, updated and
workable in the country. Since one of the major cost overrun factors is use of
incorrect/inappropriate methods of cost estimation; therefore, it is of utmost importance
to prepare proper cost estimates on the basis of WAPDA Composite Schedule of
Rates (WCSR) or otherwise on the basis of authentic market rates, where WCSR does
not fulfil the intended purpose for WAPDA projects.
2. The first WCSR was issued by WAPDA in 1979, subsequently revised during 1985-86,
1990, 1998, 2005 and 2008 considering the changes in price, working methodology
and technology.
3. As per instructions of the Authority during 2008, separate Schedule of Rates prepared
for ten different areas. These areas termed as zones comprised districts/cities having
almost similar range of rates/prices considering remote, hard, hilly terrain, plain and
easily accessible areas.
4. The previous WCSR has now been updated in eleven (11) zones keeping in view of
fluctuation and unstable costs and prices of materials, high cost of services and
machinery. This WCSR-2013 is specifically meant for Zone-2, consists of the following
districts/cities:
ZONE - 2 Lahore, Gujranwala, Sialkot, Jhang, Faisalabad, Hafizabad, Sheikhupura,

Nankana sahib, Narowal, Toba Tek Singh, Bhakkar, Sahiwal, Okara, Pakpattan
and Kasur

5. The other zone-wise distribution of districts/cities is as under:


ZONE - 1 Islamabad, Rawalpindi, Attock, Chakwal, Jhelum, Gujrat, Mandi Bahauddin,

Sargodha, Khushab, Mianwali and Mir Pur, Kotli & Bhimber (A.J.K).

ZONE - 3 Multan, Khanewal, Vehari, D.G. Khan, Rajanpur, Muzaffargarh, Layyah,

Bahawalpur, Rahim Yar Khan, Lodhran and Bahawalnagar

ZONE - 4 Sukkur, Nawab Shah, Khairpur, Larkana, Jacobabad, Shikarpur, Ghotki, Kambar

Ali Khan and Nowshero Feroze

ZONE - 5 Karachi, Hyderabad, Dadu, Jamshoro, Mirpur Khas, Tharparkar, Tando Alah

Yar, Tando Muhammad Khan, Umar Kot, Sanghar, Thatta and Badin

ZONE - 6 Peshawar, Mardan, Charsada, Swabi, Buner, Haripur, D.I. Khan, Kark,Tank,

Bannu, Laki Marwat, Kohat, Hangu,and Nowshera

ZONE - 7 Swat, Lower Dir, Upper Dir, Shangla, Malakand and Bajour, Mohmand, Khyber,

South Waziristan , North Waziristan, Orakzai & Kurram Agencies

ZONE - 8 Quetta, Loralai, Zhob, Musa Khel, Qila Abdullah, Pishin, Bhag, Gandava,

Mustang, Sibbi, Kohlu, Dera Bughti, Nasirabad, Bolan, Jhal Magsi, Ziarat,
Jaffarabad, Qila Saifullah, Barkhan.

ZONE - 9 Khuzdar, Turbat, Kalat, Kharan, Washuk, Chagai, Nushki, Panjgor, Awaran,

Gwadar and Lasbela

ZONE-10 Abbotabad, Mansehra, Buttgram, Ballakot and Muzaffarabad (A.J.K)


ZONE-11 Chitral, Dasu, Gilgit, Besham, Diamer and Sarkadu.

WAPDA

(i)

WCSR-2013 (Zone-2)

6. WCSR-2013 has been revised by incorporating basic rates of material, labour and
machinery usage for the month of November-December 2012, mostly from a subsidiary
of Pakistan Engineering Council (PEC), being reliable single source of cost data in the
construction industry. Price inflation factor has also been considered where costs of
some inputs were not available in order to bring the Schedule rates at prevailing
market level.
7. Twenty percent (20%) profit and overhead charges have been included in Rate
Analysis of composite rates, whereas three percent (3%) sundry charges have been
added only to the labour component of Rate Analysis. These factors have been worked
out considering an average rated Contractor registered/licensed with PEC.
8. The cost estimate valued on the basis of above factors, if comes out to be more than
Rs 1000 million, the same shall be adjusted by applying a premium of ten percent
(10%) on composite rates, in order to cater head office/establishment charges for
significantly big Contractors and accordingly to have a trustworthy cost estimate.
9. The Composite Items of Rates for each Zone constitute full compensation for the
completed items of works in that Zone. In cases where composite items of works do
not exist in this Schedule, the special governing conditions like distance from source of
supply to the nearest District/City Head Quarter, site of works and cost of availability of
water etc. including Contractors overhead and profit, shall be considered, in order to
prepare realistic composite rates for cost estimates.
10. The rates for items of works not covered by this Schedule shall be prepared and
approved by the respective Chief Engineers as non-scheduled items.
11. The general order/arrangement of listing of items has been kept on lines of previous
Schedule. Some improvements in different sections have been made in WCSR-2013,
whereas some obsolete Items of works have been deleted.
12. The Composite rates and the basic material, labour and machinery usage rates listed
in this Schedule are for the purpose of preparation of cost estimates for WAPDA
Projects. Therefore, neither the Contractor shall use these rates for making claim nor
shall be used for hiring labour on daily wages, under a specific preference of choice.
13. During 1998, the Authority for the guidance of its different formations published
"WAPDA Standard Specifications" of material and execution of works and "WAPDA
Drafting Standards" for material, labour and machinery usage.
14. The applicability of this Schedule is based on WAPDA Standard Specifications for
material and execution of works, 1998 (3 volumes). In case WAPDA Standard
Specifications of any work are not given in the WCSR-2013, Standard Specifications
issued by Punjab Highway and Building Departments, Public Health Engineering
Department, National Highway Authority and C. E. (Design) NTDC may be followed.
15. In case of any question regarding applicability of any particular rate, omission and
error, the matter immediately be referred to the Director (Rates), C&M, Water, WAPDA,
527- WAPDA House, Lahore for clarification. The Steering Committee (WCSR) or
Director (Rates) cannot accept any legal responsibility or liability for any error or
omission that may have been made while preparing the cost data.
16. This Schedule of Rates will be effective from January 1st 2013 and all orders,
instructions and circulars issued by the Authority or any agency there under from time
to time on this issue, shall stand repealed.

WAPDA

( ii )

WCSR-2013 (Zone-2)

17. The assignment is completed by the Rates Directorate, C&M Division, Water under the
technical support of Steering Committee, which comprises the following:
Engr: Muhammad Ali Shah
Ex-General Manager (C&M) Water

Convener

Engr: Nasir Hanif


Chief Engineer (Civil) CCC WAPDA

Member

Engr: Itebar Ali Abbasi


Chief Engineer (Contracts) C&M Water

Member

Engr: Falah-ud-Din Qureshi


Manager (Civil) NTDC

Member

Engr: P.L. Wadhwani


Director (Rates) C&M Water

Secretary

18. Following officers were also involved in the preparation of WCSR-2013 and assisted
the Steering Committee:
Engr: A.Z.K. Durrani,
Manager (Civil), NTDC
Engr: Riaz Ali Shah
Director , CCC, WAPDA
Engr: Safadar Ali Khan
Dy. Director Design (CDO) Water
Engr: Muhammad Jaffer,
Dy. Director (Rates) C&M Water
Engr; Javed Iqbal Cheema
SDO (Electrical), Building Circle, WAPDA
Engr: Umer Farooq
Jr. Engineer (Rates) C&M Water
19. The General Manager (C&M) Water would like to acknowledge with gratitude to
Mr. Muhammad Hanif, General Manager CCC WAPDA for providing valuable guidance
in the preparation of Schedule of Rates and appreciations are placed on record for the
work, dedicatedly carried out by Mr. Jawaid Akhtar Latif, Director (Contracts) C&M for
updating WCSR-2013.
20. Any suggestion for improvement in the Schedule of Rates would be welcomed.

(Sherin Khan)
General Manager (C&M) Water
Convenor Steering Committee (WCSR)

WAPDA

( iii )

WCSR-2013 (Zone-2)

Abbreviations & Symbols


Abbreviation
& Symbol

Description

AASHTO

American Association of State Highway and Transportation Officials

AC

Asbestos Cement

AC

Alternate Current

ACI

American Concrete Institute

ACSR Conductor

Aluminum Conductor Steel Reinforced Conductor

APM

Adjustable Proportionate Module

APM

Absolute Perfect Module

ASTM

American Society for Testing and Materials

B WG

Birmingham Wire Gauge

BC Batten

Bayonet Cap Batten

BCP

Brass Chromium Painted

BG

Broad Gauge

cc

Cubic Centimetre

CDO

Central Design Office, WAPDA

CI

Cast Iron

CP

Chromium Plated/Painted

cum

Cubic metre

DMO

Double Module Outlet

DPC

Damp Proof Course

DW Board

Double Wire Board

DW Board

Double Woofer Board

ECC

Earth Continuity Conductor

EI Shade

Enamel Intensive Shade

ETA type

Elektrotechnische Apparate GmbH (Circuit Protection Control) Type

FICO

Fair Isaac Corporation

GI

Galvanised Iron

gm

Grams

HP

Horse Power

HT wire

High Tension wire

kg

Kilogram

KGO

Kenndys Gauge Outlet

km

Kilometre

KM Stone

Kilo Metre Stone

L&T Section

Angle Iron (L) and Tee Iron Section

WAPDA

( iv )

WCSR-2013 (Zone-2)

Abbreviation
& Symbol

Description

LT wire

Low Tension wire

ltr

Litre

Metre

MG

Metre Gauge

mm

Milimetre

Mpa

Maga Pascal

MS

Mild Steel

NG

Narrow Gauge

No

Number

OF

Open Flume

oz

Ounce

Pa

Pascal

P.Trap

In plumbing, a trap in a P-, U-, S-, or J-shaped pipe.

PB

Polymers modified bitumen

PC Pole

Prestressed Concrete/Reinforced Concrete Pole

PCC

Plain Cment Concrete

PE

Polyethylene

PP

Polypropylene

psi

Pound per Square inch

PVC

Polyvinyl Chloride

RB

Reinforced Brick

RCC

Reinforced Cement Concrete

RCC

Roller Compacted Concrete

rpm

Revolution per minute

S.Trap

In plumbing, a trap in a P-, U-, S-, or J-shaped pipe.

sqm

Square Metre

SW Board

Single Wire Board

SW Board

Sub Woofer Board

SW Board

Switcher Board

SWG

Standard Wire Gauge

SWO

Standing Wave Outlet

UPVC

Unplasticized Polyvinyl Chloride

WC

Water Course

WC

Water Closet

WI

Wrought Iron

Diametre

WAPDA

(v)

WCSR-2013 (Zone-2)

CONVERSION FACTORS
TO CONVERT

INTO

MULTIPLY BY

LENGTH
Inch

Millimetre

25.400

Millimetre

Inch

0.039

Foot

Metre

0.305

Metre

Foot

3.281

Yard

Metre

0.914

Metre

Yard

1.094

Mile

Kilometre

1.609

Kilometre

Mile

0.621

Canal Mile (5000 ft)

Kilometre

1.524

Kilometre

Canal Mile

0.656

Mile International Nautical (6076.12 ft)

Metre

1,852.000

Mile UK Nautical (6080 ft)

Metre

1,853.180

MASS & WEIGHT


Pound

Kilogram

0.454

Kilogram

Pound

2.205

Ounce

Gram

28.350

Gram

Ounce

0.035

Quintal

Kilogram

100.000

Hundred Weight

Kilogram

50.802

Tonne

Hundred Weight

19.684

Ton

Kilogram

Ton

Tonne

1.016

Tonne

Ton

0.984

Short Ton (2000 lbs)

Tonne

0.907

1,016.046

AREA
Square Inch

Square Millimetre

Square Millimetre

Square Inch

0.002

Square Foot

Square Metre

0.093

Square Metre

Square Foot

10.764

Square Yard

Square Metre

0.836

Square Metre

Square Yard

1.196

Acre

Square Metre

Acre

Hectare

0.405

Hectare

Acre

2.471

Hectare

Square Metre

Square Mile

Square Kilometre

WAPDA

( vi )

645.160

4,046.856

10,000.000
2.590
WCSR-2013 (Zone-2)

TO CONVERT

INTO

MULTIPLY BY

Square Kilometre

Square Mile

0.386

Square Mile

Hectare

Hectare

Square Mile

0.004

Gallon (Imperial)

Litre

4.546

Cubic Foot

Litre

28.317

Cubic Metre

Litre

1,000.000

Litre

Cubic Foot

Cubic Inch

Millilitre

16.387

Fluid Ounce (UK)

Millilitre

28.413

Litre

Gallon (Imperial)

0.220

Cubic Inch

Cubic Millimetre

16,387.100

Cubic Foot

Cubic Metre

0.028

Cubic Metre

Cubic Foot

35.315

Cubic Yard

Cubic Metre

0.765

Cubic Metre

Cubic Yard

1.308

Acre Foot

Hectare Metre

0.123

Foot Per Second

Metre Per Second

0.305

Foot Per Minute

Metre Per Second

0.005

Foot Per Second

Kilometre Per Hour

1.097

Kilometre Per Hour

Foot Per Second

0.911

Mile Per Hour

Metre Per Second

0.477

Kilometre Per Hour

Mile Per Hour

0.621

Mile Per Hour

Kilometre Per Hour

1.609

Kilogram Force

Newton

9.807

Pound Force (Avoirdupois)

Newton

4.448

Ton Force

Kilo Newton

9.964

Newton

Pound Force

0.225

Kilo Newton

Ton Force

0.100

258.999

CAPACITY & VOLUME

0.035

VELOCITY/SPEED

FORCE

FORCE PER UNIT LENGTH


Pound Force Per Foot

Newton Per Metre

14.594

PRESSURE (l Pa = I N/m)
Pound Force Per Square Foot

Pascals

47.8803

Pound Force Per Square Inch

Kilo Pascals

6.89476

Ton Force Per Square Foot

Kilo Pascals

107.252

Kilo Pascals

Pound Per Square Foot

20.8354

WAPDA

( vii )

WCSR-2013 (Zone-2)

TO CONVERT

INTO

MULTIPLY BY

Ton Force Per Square Inch

Mega Pascals

15.4443

Mega Pascals

Pound Per Square Inch

145.038

MASS PER UNIT LENGTH


Pound Per Foot

Kilogram per Metre

1.488

Kilogram Per metre

Pound Per Foot

0.672

Ton Per Mile

Tonne Per Kilometre

0.631

MASS PER UNIT AREA


Ton Per Square Mile

Kilogram Per Square Kilometre

392.298

Pound Per Square Foot

Kilogram per Square Metre

4.882

Kilogram Per Square Metre

Pound Per Square Foot

0.205

MASS PER UNIT VOLUME


Pound Per Cubic Foot

Kilogram Per Cubic Metre

16.019

Pound Per Cubic Foot

Grams Per Litre

16.019

Kilogram Per Cubic Metre

Pound Per Cubic Foot

0.062

Gram Per Litre

Pound Per Cubic Foot

0.062

Cubic Foot Per Second (Cusec)

Cubic Metre Per Second (Cumecs)

0.028

Cubic Foot Per Second (Cusec)

Litre Per Second

28.317

Gallon Per Minute

Litre Per Second

0.076

Cubic Foot Per Thousand Acres

Litre Per hectare

0.069

Cubic Foot Per Thousand Acres

Cubic Metre Per Square Kilometre

0.007

Gallon Per Mile

Litre Per Kilometre

2.825

Mile Per Gallon

Kilometre Per Litre

0.354

Radian

0.017

VOLUME/RATE OF FLOW

FUEL CONSUMPTION

PLANE ANGLE
Degree
WORK, ENERGY, POWER (1J = 1Ws)
Kilowatt Hour

Kilo Joule

Foot Pound Force

Joule

1.356

Horse Power

Kilowatt

0.746

Horse Power

Kilogram Force Metre Per Second

WAPDA

( viii )

3,600.000

76.040

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

SECTION-1

CARRIAGE OF MATERIAL, LOADING AND UNLOADING


(A)
Sr.
No.
1
1.

Carriage of Material including Loading and Unloading


Description

Unit

Carriage of 3.0 cum or


5 metric tons of all
material like earth, silt,
sand, stone aggregate
spawl, coal, lime, surkhi.
Steel
girders,
M.S.
sheets, M.S. Bars etc. or
4.25 cum of timber or
3.75 metric tons of fuel
wood by truck or any
other means.
Upto 50 m

50 m

111.79

50 m to 500 m

50 m

15.82

500 m to 1 km

50 m

11.65

Over one km;


1st km

km

353.27

nd

km

64.31

rd

3 km
4th km

km
km

56.86
51.84

5th km

2 km

km

47.22

th

km

45.01

th

km

42.01

6 km
7 and subsequent kms.
2.

Rate
(Rs)
4

Specification

Remark

1.1 (30 m
lead is
converted
into 50 m)

Cement in bags
not
considered
under this item.

-do-

Carriage of 1000 Nos.


bricks 225 x 113 x 75 mm
(9 x 4 x 3) standard
size.
Upto 50 m

50 m

90.33

50 m to 500 m
500 m to 1 km

50 m
50 m

13.22
9.77

1st km
2nd km

km
km

285.96
52.05

3rd km

Over one km;

km

46.02

th

km

42.01

th

km

38.19

th

km

36.37

th

km

33.97

4 km
5 km
6 km
7 and subsequent kms.
3.

WAPDA

Carriage of 1000 No. tiles


225 x 113 x 38 mm
(9x4x1)
Upto 50 m

-do50 m

56.27
1-1

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
No.
1

Description
2
50 m to 500 m

3
50 m

500 m to 1 km
Over one km;

50 m

1st km

148.31

2 km
3rd km

km
km

26.92
23.91

4th km

km

21.71

th

km

19.90

th

km
km

18.89
17.68

5 km
6 km
7th and subsequent kms.

50 m

1.27

50 m to 500 m

50 m

0.18

500 m to 1 km
Over one km;

50 m

0.13

km

3.61

nd

km

0.61

rd

km

0.61

2 km
3 and subsequent kms
5.

-do-

Carriage of 100 No.


empty
cement
bags
including bundling.
Upto 50 m
50 m to 1 km

1.1

Carriage of cement in
bags (50 kgs).
Upto 50 m

1st km

Remark

5.07

km

nd

4.

Rate
Specification
(Rs)
4
5
6.87

Unit

50 m
50 m

1.36
0.61

1st km
2nd to 6th km

km
km

11.46
4.83

7th and subsequent kms.

km

2.21

Measured in the
shape of compact
round
bundles
and of the size
specified for work.

Over one km;

6.

WAPDA

-do-

Carriage of 3.0 cum of


Sarkanda or pilchi, Frash
or brush wood by boat or
road.
Upto 50 m

50 m

19.82

50 m to 500 m

50 m

3.19

500 m to 1 km
Over one km;

50 m

2.36

1st km
2nd km
3rd to 6th km

km
km
km

59.69
9.85
8.84

7th and subsequent kms.

km

4.43
1-2

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
Description
No.
1
2
7. Carriage
of
light
machinery weighing upto
1000 kg.
Upto 50 m

50 m

155.24

50 m

10.43

km
km

298.62

3 km
4th km

km
km

46.02
34.96

5th km

50 m to 1 km
Over one km;
1st km
nd

2 km
rd

km

34.96

km

24.12

th

km

16.48

7 and subsequent kms.

Specification

Remark

5
1.1

For machines
weighing 1000 to
1500 kgs rate be
increased by 50%
and for machines,
weighing 1500 to
3000 kgs rate
be increased by
100%.

46.02

th

6 km

8.

Rate
(Rs)
4

Unit

-do-

Carriage
of
small
consignment
weighing
upto 250 kg (job rates)
Upto 50 m

50 m

20.06

50 m to 1 km

50 m

1.68

km
km

46.02
7.64

Over one km;


1st km
2nd and subsequent kms
9.

Carriage of Bitumen, Tar


or other lubricants in
Drums (1000 Kg)
Upto 1st km
nd

2 km
rd

3
10.

and subsequent kms

For consignments
weighing 250 to
500 kgs rate be
increased by 50%
and for
consignments,
weighing 500 to
1000 kgs rate
be increased by
100%.

-dokm

49.23

km

18.69

km

12.05

Carriage of Asbestos
Cement pipes BSS Class
'B' with cement joints and
rubber ring, including
loading unloading and
stacking (Rate per 30 m
pipes).

1.1 to 1.2
which ever is
applicable

i) 75 mm
Upto 50 m

50 m

4.83

50 m to 500 m

50 m

0.83

500 m to 1 km

50 m

0.61

km

14.75

km
km

1.60
1.60

Over one km;


1st km
nd

2 km
3rd km

WAPDA

1-3

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
No.
1

Rate
Specification
(Rs)
4
5
1.20
1.20

Description

Unit

2
4 km
5th km

3
km
km

6th km

km

1.20

km

0.61

Upto 50 m
50 m to 500 m

50 m
50 m

5.90
0.96

500 m to 1 km

50 m

0.71

1st km
2nd km

km
km

17.22
2.21

3rd km

th

th

7 and subsequent kms.

Remark
6

ii) 100 mm

Over one km;

km

1.60

th

km

1.60

th

km

1.60

th

km

1.60

th

km

0.63

Upto 50 m
50 m to 500 m

50 m
50 m

8.30
1.49

500 m to 1 km

50 m

1.09

4 km
5 km
6 km
7 and subsequent kms.
iii) 150 mm

Over one km;


1st km

km

26.22

nd

km

5.42

rd

3 km
4th km

km
km

2.81
2.21

5th km

2 km

km

2.21

th

km

2.21

th

km

1.20

Upto 50 m

50 m

14.86

50 m to 500 m

50 m

2.50

500 m to 1 km

50 m

1.85

km

44.86

2 km
3rd km

km
km

5.02
5.02

4th km

6 km
7 and subsequent kms.
iv) 200 mm

Over one km;


1st km
nd

km

3.82

th

km

3.82

th

km
km

3.21
1.60

5 km
6 km
7th and subsequent kms.
WAPDA

1-4

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
No.
1

Description
2
v) 250 mm

Unit

Rate
(Rs)
4

Upto 50 m

50 m

23.14

50 m to 500 m
500 m to 1 km

50 m
50 m

3.93
2.90

1st km
2nd km

km
km

70.31
8.23

3rd km

Specification

Remark

Over one km;

km

7.03

th

km

6.63

th

5 km
6th km

km
km

5.42
5.42

7th and subsequent kms.

km

2.81

Upto 50 m
50 m to 500 m

50 m
50 m

31.43
5.33

500 m to 1 km

50 m

3.93

1st km
2nd km

km
km

95.07
10.85

3rd km

4 km

vi) 300 mm

Over one km;

km

9.85

th

km

8.84

th

5 km
6th km

km
km

7.64
7.03

7th and subsequent kms.

km

7.03

Upto 50 m

50 m

60.70

50 m to 500 m

50 m

10.30

500 m to 1 km

50 m

7.59

Over one km;


1st km

4 km

vii) 400 mm

km

183.56

nd

km

21.31

rd

km

19.09

th

4 km
5th km

km
km

16.48
14.87

6th km

km

14.26

km

7.64

2 km
3 km

th

7 and subsequent kms.


viii) 450 mm

WAPDA

Upto 50 m

50 m

103.49

50 m to 500 m

50 m

17.59

500 m to 1 km

50 m

12.95
1-5

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
No.
1

Description
2
Over one km;
1st km

Rate
(Rs)
4

Unit
3
km

312.96

nd

km

36.17

rd

km

32.75

th

4 km
5th km

km
km

28.53
25.72

6th km

km

24.12

km

13.06

Upto 50 m

50 m

113.95

50 m to 500 m

50 m

19.37

500 m to 1 km
Over one km;

50 m

14.25

2 km
3 km

th

7 and subsequent kms.

Specification

Remark

ix) 508 mm

1st km

km

323.13

nd

km

39.67

rd

3 km
4th km

km
km

35.92
31.30

5th km

2 km

km

28.22

th

km

26.46

th

km

14.33

Upto 50 m

50 m

129.05

50 m to 500 m

50 m

21.93

500 m to 1 km
Over one km;

50 m

16.14

6 km
7 and subsequent kms.
x) 600 mm

1st km

km

366.07

nd

km

44.81

rd

3 km
4th km

km
km

40.39
35.57

5th km

2 km

km

31.75

th

km

29.54

th

km

16.48

6 km
7 and subsequent kms.
11.

WAPDA

Carriage of PVC pipes


BSS Class 'B', C, D
and E including loading
unloading and stacking
(Rate per 300 m pipes)
i) 50 mm
Upto 50 m
50 m to 500 m
500 m to 1 km

1.1 to 1.2
which ever is
applicable

50 m
50 m
50 m

11.40
1.93
1.42
1-6

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
No.
1

Description
2
Over one km;
1st km

Rate
(Rs)
4

Unit
3
km

32.28

nd

km

3.98

rd

km

3.62

th

4 km
5th km

km
km

3.62
2.66

6th km

km

2.66

km

1.33

Upto 50 m

50 m

18.86

50 m to 500 m

50 m

3.20

500 m to 1 km
Over one km;

50 m

2.36

2 km
3 km

th

7 and subsequent kms.

Specification

Remark

ii) 63 mm

1st km

km

53.48

nd

km

6.51

rd

3 km
4th km

km
km

5.91
5.30

5th km

2 km

km

4.58

th

km

4.22

th

km

2.29

Upto 50 m

50 m

27.50

50 m to 500 m

50 m

4.67

500 m to 1 km
Over one km;

50 m

3.44

6 km
7 and subsequent kms.
iii) 75 mm

1st km

km

78.01

nd

km

9.52

rd

3 km
4th km

km
km

8.56
7.60

5th km

2 km

km

6.87

th

km

6.27

th

km

3.62

Upto 50 m

50 m

38.91

50 m to 500 m

50 m

6.61

500 m to 1 km

50 m

4.87

6 km
7 and subsequent kms.
iv) 100 mm

Over one km;


1st km
nd

2 km

WAPDA

km

110.37

km

13.51

1-7

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
No.
1

Rate
Specification
(Rs)
4
5
12.18
10.49

Description

Unit

2
3 km
4th km

3
km
km

5th km

km

9.52

km
km

8.92
4.94

Upto 50 m

50 m

68.78

50 m to 500 m
500 m to 1 km

50 m
50 m

11.69
8.61

km

195.08

2 km
3rd km

km
km

23.99
21.70

4th km

rd

th

6 km
7th and subsequent kms.

Remark
6

v) 125 mm

Over one km;


1st km
nd

km

17.12

th

km

15.80

th

km
km

14.95
12.05

Upto 50 m

50 m

101.67

50 m to 500 m
500 m to 1 km

50 m
50 m

17.28
12.73

km

288.39

2 km
3rd km

km
km

35.45
32.19

4th km

km

27.98

5 km
6th km

km
km

24.95
23.27

7th and subsequent kms.

km

12.78

Upto 50 m
50 m to 500 m

50 m
50 m

161.57
27.46

500 m to 1 km

50 m

20.22

1st km
2nd km

km
km

458.24
56.04

3rd km

5 km
6 km
7th and subsequent kms.
vi) 150 mm

Over one km;


1st km
nd

th

vii) 200 mm

Over one km;

km

50.92

th

km

44.29

th

km

39.88

th

km

37.08

4 km
5 km
6 km
WAPDA

1-8

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
No.
1

Description

Unit

2
7 and subsequent kms.

3
km

th

Rate
Specification
(Rs)
4
5
20.23

Remark
6

viii) 250 mm
Upto 50 m

50 m

255.11

50 m to 500 m

50 m

43.37

500 m to 1 km

50 m

31.93

km

723.62

2 km
3rd km

km
km

88.48
80.41

4th km

Over one km;


1st km
nd

km

69.99

th

km

62.79

th

km
km

58.81
32.76

Upto 50 m
50 m to 500 m

50 m
50 m

363.07
61.70

500 m to 1 km

50 m

45.43

5 km
6 km
7th and subsequent kms.
ix) 300 mm

Over one km;


1st km
2nd km

km
km

1029.76
125.92

3rd km

km

114.43

th

km

99.54

th

5 km
6th km

km
km

89.61
83.33

7th and subsequent kms.

km

45.45

Upto 50 m
50 m to 500 m

50 m
50 m

462.71
78.66

500 m to 1 km

50 m

57.92

4 km

x) 350 mm

Over one km;


1st km
2nd km

km
km

1312.48
160.48

3rd km

km

145.85

4 km
5th km

km
km

126.94
113.88

6th km

km

106.67

km

59.41

th

th

7 and subsequent kms.

WAPDA

1-9

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Note:
1

The rates for items not in this Schedule can be deduced from these basic rates on the following
assumption;
Quantities of different materials equivalent to 1000 No. bricks 225x113x75 mm size,
3.0 cu.m. or 5 ton weight with almost similar amount of labour involved in loading,
unloading and stacking shall have rates equivalent to these basic rates. Fluctuation if any
shall be proportionate to the increase or decrease in the weight, volume or labour
involved.

The rates are applicable to carriage of materials on pacca roads only. For kacha roads an
allowance of extra 25% shall be allowed for 2nd and subsequent Kilometre rates. Rates upto
1st Kilometre is however common to both kacha and pacca roads.

For hilly areas, 25% above the rates in the plain areas shall be allowed for total Kilometres
covered.

In case of articles longer than 4.50 m carried in trucks, the following rates shall be allowed as
under:
a) Above 4.50 to 7.50 m :- Total rate to be paid for 4.50 m to 7.50 m length will be
1.5 times the rates given in the Composite Schedule of Rates.
b) Above 7.50 m :- The total rates to be paid for above 7.50 m length will be 2 times of
the rate given in Composite Schedule of Rates.

The term Kilometre wherever used is to mean statute Kilometre.

The rate included loading and unloading of material and conveyance and staking as directed.

WAPDA

1-10

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

(B)

Loading, Unloading and Stacking

Sr.
Description
No.
1
2
1. Loading or unloading earth,
sand, silt, Shingle, surkhi,
ashes, kankar, brick ballast,
coal, and lime etc. laid/piled
and stacked lead within
30m.
2.

Unit
3
cum

Rate
(Rs)
4
100.88

Loading
or
unloading
bricks/tiles properly laid and
stacked lead within 30 m.

Specification

Remark

5
1.2

-do-

a) 225 mm or larger.

1000 no

378.39

b) smaller than 225 mm.

1000 no

302.63

3.

Loading
or
unloading
cement in bags and stacking
within 30 m.

100 bags

378.39

-do-

4.

Loading or unloading empty


cement bags and stacking.

100 bags

36.37

-do-

5.

Loading or unloading white


lime in bags and stacking
within 30 m.

1000 kg

60.89

-do-

6.

Loading
or
unloading
structural steel, steel joist
and other steel items.

1000 kg

181.66

-do-

7.

Loading or unloading up to
225 litres drum full, lead upto
30 m.

each

24.31

-do-

8.

Loading
or
unloading
packages or stocks all sorts
upto 50 kg (except cement,
jute or paper bags).

each

12.05

-do-

9.

Loading or unloading timber


logs or timber for shuttering
of any gauge including
stacking lead within 30 m.

1000 kg

85.41

-do-

10.

Loading
or
unloading
bhoosa lead upto 45 m.

100 kg

24.31

-do-

11.

Loading or unloading timber


scrap or wooden plugs and
stacking with 30 m.

1000 kg

151.32

-do-

12.

Loading
or
unloading
pitching stone or spawl of
any gauge (clear distance
1.50m).

cum

226.98

1.2

WAPDA

1-11

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
Description
No.
1
2
13. Loading
or
unloading
building
stone
(clear
distance 1.50m).
14.

Unloading oil, bitumen, tar


etc.
a) Crude oil (to be pumped
from tank into tank

3
cum

Rate
(Rs)
4
302.64

84.00

b) Crude oil (drained by


gravity)

1000 litre

84.00

c) Crude oil materials

cum
1000 kg

33.13
138.45

100 no

190.70

100 no

380.80

f) Kerosine oil (16 litre)


Removing
and
stacking
within 30 m
a) Stones, spawls, brick
bats, shingle, sand, lime
surkhi, ashes, kankar &
coal etc.
b) Bricks

Specification

Remark

5
-do-

-do1000 litre

d) Fuel oil from tank drums


including stacking within
30 m
e) Petrol (9 litre tin)

15.

Unit

-docum

53.45

1000 no

438.87

c) Steel girders, rails, pipes,


cement etc.

1000 kg

229.98

d) Broad gauge
sleepers.

wooden

100 no

2421.65

e) Metre gauge or narrow


gauge wooden sleepers.

100 no

1383.34

f)

crossing

100 no

808.23

16.

Loading steel girders, rails,


iron work, MS bars, pipes
etc.
lead 30 m
and
stacking.

1000 kg

193.71

-do-

17.

Unloading steel girders,


rails, iron work, MS bars,
pipes etc. lead upto 30m
excluding stacking.

1000 kg

96.86

-do-

18.

Loading
wooden
broad
gauge sleepers including
lead 30 m and stacking.

100 no

605.47

-do-

19.

Unloading wooden broad


gauge sleepers including
lead 30 m and stacking.

100 no

302.63

1.2

WAPDA

Bridge
timber.

and

1-12

WCSR-2013 (Zone-2)

SECTION 1 CARRIAGE OF MATERIAL, LOADING AND UNLODING

Sr.
Description
No.
1
2
20. Loading wooden metre/
narrow
gauge
sleepers
including lead upto 30 m and
stacking.

3
100 no

Rate
(Rs)
4
332.97

Unit

Specification

Remark

5
-do-

21.

Unloading wooden metre/


narrow
gauge
sleepers
including lead upto 30 m and
stacking.

100 no

160.36

-do-

22.

Loading bridge and crossing


timber including lead upto
30m and excluding stacking.

cum

100.88

-do-

23.

Unloading
bridge
and
crossing timber including
lead upto 30m and excluding
stacking.

cum

53.45

-do-

WAPDA

1-13

WCSR-2013 (Zone-2)

SECTION 2 EARTHWORK (EXCAVATION AND EMBANKMENT)

SECTION-2

EARTHWORK (EXCAVATION AND EMBANKMENT)


Sr.
No.
1
1.

Description

Unit

Earthwork
excavation
undressed lead of a
single throw of shovel.
a) In ashes, sand, soft
soil or silt clearance
b) In ordinary soil.

2.

Earthwork excavation in
ashes, sand and soft soil
or
silt
clearance,
undressed lead upto
30 m.

3.

Borrow pit excavation


undressed lead upto
50 m.
a) Ordinary soil
b) Hard soil

4.

5.

Excavation in shingle or
gravel formation and rock
not requiring blasting
undressed lead upto
50 m.
a) Dry

WAPDA

cum

78.31

cum

94.33

cum

115.10

cum
cum

2.1 to
2.8
which
ever is
applica
ble

Remark
7
.

-do-

146.54
180.36
-do-

398.09

b) Wet

cum

460.98

c) In flowing water

cum

586.75

Earthwork excavation in
irrigation channels, drains
etc., dressed to designed
section
grades
and
profiles,
excavated
material disposed off and
dressed within lead of
30 m.
a) Ordinary soil

Specifi
cation
6

-do-

cum

-do-

cum

171.80

b) Hard soil

cum

205.62

c) Very hard soil

cum
cum

241.22
449.34

d) Shingle and gravel


formation
6.

Rate (Rs)
Labour Composite
4
5

Excavation
in
rock
dressed to designed
section,
grades
and
profiles,
excavated
material disposed off
within lead of 50 m and
lift upto 1.5 m.

-do-

2-1

WCSR-2013 (Zone-2)

SECTION 2 EARTHWORK (EXCAVATION AND EMBANKMENT)

Sr.
No.
1

7.

Description

Unit

2
a) Soft rock slate, shale
schist or laterite work
with pick and crow
bar.
b) Medium hard rock
requiring occasional
blasting.

3
cum

Grade-I
Grade-II
Grade-III
Grade-IV
Grade-V
Grade-VI

8.

Excavation in hard rock


requiring blasting but
blasting prohibited and
disposal of excavated
material
(blasted
material) upto 30 m lead
(including dressing and
leveling
to
designed
section etc. complete).

9.

Extra for every 15m


additional lead or part
thereof upto a lead of
1 km.

11.

WAPDA

639.02

cum
cum
cum
cum
cum
cum

369.40
400.96
479.71
535.47
592.56
639.05

cum

a) For earth work (soft,


ordinary, hard and
very hard).

cum

3.56

b) For gravel shingle or


rock.

cum

4.15

Re-handling of earthwork
a) Lead
upto
single
throw of shovel.

cum

52.21

b) Upto a lead of 30 m.

cum

73.57

Re-handling of gravel
work or excavated rock
lead upto 30 m.

cum

209.43

2-2

Specifi
cation
6

Remark
7

661.15

Excavation in hard rock


requiring blasting and
disposal of excavated
material
(blasted
material) up to 30 m lead
(including dressing and
leveling
to
designed
section etc. complete)
i)
ii)
iii)
iv)
v)
vi)

10.

cum

Rate (Rs)
Labour Composite
4
5
524.65

2.1 to
2.8
which
ever is
applica
ble

Reduce the
rate by 10% if
the excavated
section is not
dressed or
leveled to
designed
section.

-do-

Add 100% to
the rate as
applicable in
item 7.

-do-

Carriage
of
material will
be paid for
lead
more
than 1 km.

391.53
437.92
523.97
587.03
651.65
705.44

-do-

-do-

WCSR-2013 (Zone-2)

SECTION 2 EARTHWORK (EXCAVATION AND EMBANKMENT)

Sr.
Description
No.
1
2
12. Dressing and leveling of
earthwork to designed
section complete.

Unit
3

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6
2.1 to
2.8
which
ever is
applica
ble

a) Ashes, sand, silt or


soft soil.

cum

7.43

b) Ordinary or hard soil.

cum

15.37

c) Gravel work or soft


rock (not requiring
blasting).

cum

29.77

13.

Refilling the excavated


stuff in trenches in
150 mm thick layers
including
watering,
ramming to compaction
etc., complete.

cum

192.82

-do-

14.

Dowel dressing of canal


banks, marginal bunds,
and
flood
protection
bunds.

8.87

-do-

15.

Earthwork
compaction
(soft, ordinary or hard soil)
a) Laying
earth
in
150 mm layers /
leveling dressing and
watering
for
compaction
etc.
complete.

-docum

27.67

36.85

As per ASTMD698 /
AASHTO-T99
or as specified
by the
Engineer.

b) Compaction by roller.
i) Soft or sandy soil

cum

35.94

40.71

ii) Ordinary soil

cum

42.44

47.21

iii) Hard soil

cum

47.19

51.96

iv) Admixture of
shingle

cum

53.68

58.45

c) Ramming earthwork
(all type of soil)

cum

31.44

d) Ramming earthwork
behind retaining wall.

cum

42.12

16.

Excavation in puddling
slush
including
dewatering
through
mechanical means and
arrangements.

cum

167.90

17.

Earthwork excavation in
open cutting upto 1.5 m
depth for storm water
channels, drains, salluge

WAPDA

Remark

196.04

-do-

-do-

2-3

WCSR-2013 (Zone-2)

SECTION 2 EARTHWORK (EXCAVATION AND EMBANKMENT)

Sr.
No.
1

18.

Unit

2
drains in open areas,
roads, streets, lanes
including under pinning of
walls and shoring to
protect existing works,
shuttering and timbering
to trenches, dressing
sides to true alignment,
shape, dimensions and
level to correct limit and
grade, removal of surface
water from trenches,
back filling and surplus
excavated
material
disposed off and dressed
within 30 m.
i) In ordinary soil

cum

184.34

ii) In hard soil

cum

198.02

iii) Gravel and shingle


formation

cum

287.17

Excavation
in
open
cutting for sewer and
manholes as shown in
drawing,
dressing
to
correct
section
and
dimension according to
template and levels and
removing surface water
in all types of soil shingle,
gravel and rock.
i) 0 2.0 m
ii) 2.0 - 4.5 m
iii) above 4.5 m

19.

Providing and fixing open


shuttering and timbering
for item 20 and removing
of
timbering
after
completion of job.
i) 0 2.0 m
ii) 2.0 - 4.5 m
iii) above 4.5 m

20.

WAPDA

Rate (Rs)
Labour Composite
4
5

Description

Excavation of trenches
for water supply pipe
lines in all kinds of soil,
hard, average or soft
Upto 1.5 m depth from
ground level, including
trimming, dressing sides,
leveling the bed of trench

Specifi
cation
6
2.1 to
2.8
which
ever is
applica
ble

Remark
7

-do-

cum
cum

183.17
251.55

cum

335.20
-do-

sqm

39.45

194.05

sqm
sqm

49.84
56.06

255.29
312.38

cum

188.66

2-4

-do-

WCSR-2013 (Zone-2)

SECTION 2 EARTHWORK (EXCAVATION AND EMBANKMENT)

Sr.
No.
1

Description

Unit

21.

Earthwork in small rain


water drains, along canal
banks,
roads,
and
plantation drains, dressed
etc.

22.

Excavation in foundation
of buildings, bridges and
other structures including
dibbling dressing, refilling
around structure with
excavated earth, watering
and ramming lead upto
30 m and lift upto 1.5 m.
a) In sand, ashes or
loose soil.
b) In ordinary soil.

to correct grade and


cutting in pits for joints.

Rate (Rs)
Labour Composite
4
5

1.78

Specifi
cation
6
2.1 to
2.8
which
ever is
applica
ble

193.16

cum

226.92

c) In hard soil or soft


soil

cum

254.18

23.

Cutting hard rock such as


granite, ballast, hard lime
stone or sand-stone etc.
with chisels and hammers
for small foundations.

cum

1538.69

1724.66

-do-

24.

Extra
for
excavation
requiring shoring.

cum

28.77

63.74

-do-

25.

Filling
watering
and
ramming earth under
floors with surplus earth
from foundation.

cum

102.59

-do-

26.

Filling
watering
and
ramming earth under
floors with new earth
(excavation from outside)
lead upto 30 m and lift
upto 1.5 m.

cum

173.51

-do-

27.

Filling and compacting


soil, earth and boulders
behind retaining walls
(including excavation of
soil and lead upto 30 m).

cum

229.54

-do-

28.

Dressing of banks
ground surface.

sqm

9.38

-do-

29.

Dag belling 75 mm deep.

km

1325.99

-do-

WAPDA

-do-

cum

or

Remark

2-5

WCSR-2013 (Zone-2)

SECTION 2 EARTHWORK (EXCAVATION AND EMBANKMENT)

Sr.
No.
1
30.

31.

32.

Description

Unit

2
Turfing slopes of banks or
lawns with grass sods
including plugging, laying,
setting and watering (turf
got from within a distance
of
10kms
and
maintenance
for
15
days).

3
sqm

Berm cutting
a) Lead upto a single
throw of shovel.
b) Upto 30 m.
Both sides Berm trimming
including channel 1.0 m
wide:
a) Upto 1.0 m depth
b) From 1.0 - 1.5 m
depth
c) From 1.5 - 2.5 m
depth

Rate (Rs)
Labour Composite
4
5
255.70

cum

94.33

cum

146.54

Specifi
cation
6
2.1 to
2.8
which
ever is
applica
ble

Remark
7

-do-

-dokm
km

5321.32
7059.36

km

11194.9
8

33.

Plugging and leveling hectare 5627.24


borrow
pits
(area
ploughed
to
be
measured)

-do-

34.

Making boundary service


roads
including
dag
belling,
leveling
and
dressing in unplugged
land:
a) From 3.0 to 6.0 m
wide

-do-

Extra Rs.15
may be paid
for ploughed
land.

-do-

For ordinary
soil.

b) From 6.0 to 12.0m


wide
35.

36.

WAPDA

Earthwork by boat.
a) Digging and loading
into boat upto 15 m.

31.85

43.40

cum

157.22

b) Carriage by boat upto


300 m.

cum

63.07

c) Extra for distance


beyond 300 m per
30 m.

cum

4.16

d) Unloading earth from


boats.

cum

73.57

Unloading
trucks.

cum

62.89

earth

from

2-6

-do-

WCSR-2013 (Zone-2)

SECTION 2 EARTHWORK (EXCAVATION AND EMBANKMENT)

Sr.
No.
1
37.

Description

Unit

2
Termite proofing with
approved chemicals.
i) Pre Construction:

ii)

Post Construction:

Rate (Rs)
Labour Composite
4
5

sqm

46.87

130.49

Per
hole

51.62

118.52

Specifi
cation
6
2.1 to
2.8
which
ever is
applica
ble

Remark
7

Drilling depth
450-600 mm

EARTHWORK BY
MECHANICAL MEANS
38.

39.

Excavation in all kind of


Ordinary Soil/Borrow area
under following condition
dressed
to
designed
level, section, grades,
and profile within 100 m
lead as directed by the
Engineer.

Borrow area
to be
approved by
the Engineer/
Employer.

i)

Dry

cum

68.86

ii)

Dry and wet

cum

73.92

Excavation in all kind of


Ordinary soil in drains
and irrigation channels
under following condition
dressed
to
designed
level, section, grades,
and profile within 100 m
lead as directed by the
Engineer.
i)

Wet and slush (1:1)

cum

82.95

ii)

Wet and slush (1:2)

cum

86.72

iii) Slush

cum

90.81

iv) Under water

cum

114.59

40.

Extra for Item 38 & 39;


for every 15 m additional
lead or part thereof upto a
lead of 1 km.

cum

6.21

41.

Earthwork in ordinary soil


for embankment lead up
to
50 m
including
plugging and mixing with
blade or disc harrow or
other suitable equipment
and
compaction
by
mechanical means at
optimum
moisture
contents and dressing
to designed
section,

WAPDA

Carriage of
material will
be paid for
lead more
than 1 km.
As per ASTMD1557 /
AASHTO-T180
or as specified
by the
Engineer.

2-7

WCSR-2013 (Zone-2)

SECTION 2 EARTHWORK (EXCAVATION AND EMBANKMENT)

Sr.
No.
1

Description

Unit

Rate (Rs)
Labour Composite
4
5

2
complete in all respects.

i. More than 95% of dry


density.

cum

42.44

89.30

ii. 90% to 95% of dry


density.

cum

42.44

85.47

Specifi
cation
6

Remark
7

CONVERSION TABLE

In the case of earthwork measurement where extra lead is to be paid for lift the method will be as
follows:
The lift will be measured from the centre of gravity of the excavated earth to that of placed earth. This
will constitute the mean lift for the section.
When earth has to be carried over a spoil bank and dumped beyond it the mean lift would be the
difference in level between the centre of gravity of the excavated earth and the top of the spoil bank
omitting the dowel.
The equivalent leads for various means lifts are given below:
Lift in Meters
0.5
1.0
1.5
2.0

Conversion
factor
8
10

Equivalent Horizontal
lead in Meters
4
8
15
20
25
36

3.5

47

4.0
4.5
5.0
5.5
6.0
6.5
7.0

3.28 x Lift in Meter + 2

2.5
3.0

60
75
92
110
130
152
175

7.5
8.0

200
216

8.5

230

9.0

27

243

9.5

257

10.0

270

Note:
These conversion factors also incorporate allowance for extra lead due to cross lead with a view
to ensuring a uniform system. The equivalent lead will be added to the horizontal lead to get the
total lead to be paid. The exact site or R.D.s between which extra lead is to be given must be
recorded in the first column of detailed measurements in the Measurement Book.

WAPDA

2-8

WCSR-2013 (Zone-2)

SECTION 3 DISMANTLING (DEMOLITION)

SECTION- 3

DISMANTLING (DEMOLITION)
1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.

Sr.
No.
1
1.

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Description

Unit

STONE WORK
Dismantling dry stone
masonry.

cum

177.98

3.1 to
3.3

stone
cement

cum

625.23

-do-

2.

Dismantling
masonry
in
mortar.

3.

Dismantling dry
spall pitching.

stone

cum

314.44

-do-

4.

Dismantling stone or
spall pitching and apron
in silted condition.

cum

521.32

-do-

5.

Dismantling
stone
pitching cement grouted.

cum

834.24

-do-

6.

Dismantling stones in:

7.

-do-

a) Wooden crates.

cum

416.82

b) Wire crates

cum

521.32

cum

421.29

-do-

Dismantling stone ware


drain
including
base
concrete.

Remark
7

Add extra
15%, 30% &
50% on
labour rate
only for 2nd,
3rd, 4th and
subsequent
floors
respectively
against
items No.3,
10, 11, 12,
14, 15, 18,
19, 24, 25,
33, 39, 40
and 41.

BRICK WORK
8.

Dismantling
masonry.

dry

brick

cum

177.12

-do-

9.

Dismantling brick work in


cement mortar.

cum

886.19

-do-

10.

Dismantling
wall.

cum

208.41

-do-

-do-

perforated

CONCRETE
11.

Dismantling
concrete

cement

cum

573.28

12.

Dismantling
cement
concrete block masonry.

cum

781.69

WAPDA

3-1

WCSR-2013 (Zone-2)

SECTION 3 DISMANTLING (DEMOLITION)

Sr.
No.
1

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Description

Unit

Dismantling
cement
concrete under water.

cum

2189.20

3.1 to
3.3

14. a) Dismantling cement


concrete plain 1:4:8

cum

1146.56

-do-

b) Dismantling cement
concrete plain 1:3:6.

cum

1876.29

-do-

c) Dismantling cement
concrete plain 1:2:4

cum

2293.70

-do-

d) Dismantling cement
concrete with brick
aggregate

cum

625.23

-do-

e) Dismantling D.P.C. of
cement
concrete
40mm
thick
and
clearing the site etc

cum

312.91

-do-

Dismantling
cement
concrete
reinforced
separating reinforcement
from concrete cleaning
and straightening the
same.

cum

3753.17

-do-

sqm

38.38

-do-

13.

15.

16.

ROOFING
Dismantling G.I. sheet
roofing.

17.

Dismantling
roof
of
wooden
planks
and
battens.

sqm

45.09

-do-

18.

Dismantling
asbestos
sheets and ridge coping.

sqm

53.60

-do-

19.

Dismantling
roofing.

tile

sqm

95.05

-do-

20.

Dismantling
wooden
ceiling above 6m height
in
difficult
position,
including lifting with care
and special scaffolding
along live electric wires
and
with
machines
underneath.

sqm

172.94

-do-

21.

Dismantling jack arch


roofing including removal
of joists.

sqm

127.56

-do-

WAPDA

brick

3-2

Remark
7

WCSR-2013 (Zone-2)

SECTION 3 DISMANTLING (DEMOLITION)

Sr.
No.
1
22.

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Description

Unit

a) Stripping and stacking


slates or tiles from the
truss roofing.

sqm

107.83

3.1 to
3.3

b) Stripping and stacking


(G.I. Sheet roof).

sqm

74.46

-do-

sqm

53.99

-do-

sqm

80.09

-do-

Remark
7

FLOORING
23.

Dismantling
brick
concrete flooring.

or

24.

Dismantling tile flooring.

25.

Disjointing R.C.C. pipes


inside the trench and
dismantling and removing
the pipes from the trench
and
stacking
them
outside.

-do-

a) 150 to 300 mm

24.32

b) 300 to 600 mm

33.82

c) 600 to 900 mm

43.90

d) Above 900 mm

42.52

26. a) Removing
door,
window and frame.

no

272.91

-do-

c) Removing Windows
and sky light with
frame.

no

196.77

-do-

27.

Removing ventilators and


wooden sunshades etc.

no

98.39

-do-

28.

a) Dismantling wooden
beams upto 3.5m in
length

no

148.32

-do-

b) Dismantling wooden
beams from 3.5m to
7.0 m length

no

296.64

-do-

29.

Dismantling
wooden
partition jaffery work.

sqm

37.38

-do-

30.

Dismantling
trusses.

wooden

kg.

10.33

-do-

31.

Dismantling
wooden
palisade fencing.

97.89

-do-

WOODWORK

WAPDA

3-3

WCSR-2013 (Zone-2)

SECTION 3 DISMANTLING (DEMOLITION)

Sr.
No.
1

Description

Unit

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Remark
7

IRON WORK
32.

Dismantling iron work of


trusses, sheds, water
tanks, etc.

kg.

10.48

3.1 to
3.2

33.

Dismantling rolled steel


beams, iron grill or iron
rail etc.

kg.

4.75

-do-

34.

Dismantling tees, bends


or sluice valves upto
300 mm .

each

45.94

-do-

35.

Dismantling all type of


wire fencing including
rolling wires into bundles
and collecting materials.

17.21

-do-

sqm

25.51

-do-

36.

MISCELLANEOUS
Dismantling wire netting
of tennis courts and
frame work.

37.

Dismantling cloth ceiling


and supporting timber.

sqm

48.06

-do-

38.

Dismantling and removing


road metalling.

cum

418.86

-do-

39.

Removing cement plaster.

sqm

25.51

-do-

a) Whitewash or colour
wash.

sqm

16.02

-do-

b) Ordinary distemper,
oil bound distemper,
or paint on wall

sqm

48.06

-do-

41.

Dismantling glazed
encaustic tiles etc.

sqm

169.25

-do-

42.

Scraping boulders.

cum

733.29

-do-

43.

Cleaning mortar of old


stones to be reused in
masonry.

cum

366.65

-do-

SCRAPING
40.

WAPDA

or

3-4

WCSR-2013 (Zone-2)

SECTION 4 MORTAR

SECTION- 4
M O R T A R
Dry material required for 1.00 cum Wet (including wastage) mortar.
Cement
(50 kg bag)

Quantity
Sand
(cum)

Cement Sand
1:2

13.64

0.97

1:3

10.23

1.09

1:4
1:5

8.19
6.80

1.16
1.21

1:6

5.85

1.24

1:7

5.12

1.27

1:8

4.55

1.29

1:1:3

7.802

0.415

0.829

1:2:4
1:3:6

6.130
4.290

0.434
0.456

0.869
0.912

1:4:8

3.300

0.468

0.935

1:5:10

2.682

0.475

0.950

Sr. No

Ratio of Mortar

1.

2.

Aggregate
(cum)

Cement Concrete

Wet mortar required for 1.00 cum masonry


Sr.No.

Mix

1.

Brick Masonry (Cement Sand)

2.

Stone Masonry (Cement Sand)

Quantity
0.250 cum (25%)

a) Random rubble, uncoursed


Foundation and plinth
Super structure
Coursed

Note:

WAPDA

0.464 cum (46%)


0.393 cum (39%)
0.357 cum (36%)

b) Ashler block masonry

0.214 cum (21%)

c) Ashler fine masonry

0.214 cum (21%)

1)

Cement

1.0 cum contains (1290-1540) kg

2)

Sand

1.0 cum contains (1450-1650) kg

3)

Aggregate

1.0 cum contains (1725-1920) kg

4-1

WCSR-2013 (Zone-2)

SECTION 5 CONCRETE

SECTION- 5

C O N C R E T E
1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.

Sr.
Description
No.
1
2
1. Cement concrete with
brick or stone ballast 40 to
50mm
size
in
foundation and plinth.
Ratio:
a) 1:3:6
b) 1:4:8
2.

3.

Cement concrete plain


including
placing,
compacting, finishing and
curing complete (including
screening and washing of
stone aggregate) without
shuttering.
Ratio:
a) 1::3

Unit
3

Rate (Rs)
Labour Composite
4
5

cum

1234.54

4800.51

cum

1234.54

4091.72

Specifi
cation
6
5.6

Remark
7

-do-

cum

1690.27

7628.62

b) 1:2:4

cum

1690.27

6748.05

c) 1:3:6
d) 1:4:8

cum
cum

1690.27
1690.27

6010.45
5280.98

Reinforced
cement
concrete
work
using
coarse sand except the
cost
of
steel
reinforcement and its
labour for bending and
binding. This rate also
includes all kinds of
forms
moulds;
lifting
shuttering,
curing,
rendering and finishing
the exposed surface
(including screening and
washing of shingle).

5.6 &
5.10

a) In-situ in roof slabs,


beams, columns, rafts,
lintels
and
other
structural
members
complete in all respect.
WAPDA

5-1

WCSR-2013 (Zone-2)

SECTION 5 CONCRETE

Sr.
No.
1

Rate (Rs)
Labour Composite
4
5

Description

Unit

i) 1:2:4

cum

7207.32

13503.95

ii) 1:1:3

cum

7207.32

14375.58

Specifi
cation
6

Remark
7

Ratio:

b) Precast in columns
beams, slab, lintel,
staircases, shelves,
etc.
Ratio:

4.

5.
WAPDA

i) 1:2:4

cum

6840.23

13979.39

ii) 1:1:3

cum

6840.23

13418.42

c) Erecting and fixing in


position
precast
cement concrete or
stone slab in roofs or
lintels, etc. lift upto
first floor including all
charges.

cum

2004.12

2468.06

d) Add extra labour for


R.C. concrete in 2nd
and
subsequent
stories.

cum

838.30

Providing and casting in


situ bored RCC piles in
1:1:3 cement concrete
of approved crushed
stone and coarse sand
including all costs of
boring drilling with rotary,
reverse rotary or any
approved
method,
placing concrete with
tremie excluding cost of
supply and fabrication of
steel bars reinforcement
cage, which shall be paid
separately
including
screening and washing of
shingle;
i) 450 mm

3103.84

6298.81

ii)

4036.28

8483.51

iii) 900 mm
iv) 1200 mm

m
m

5941.70
5993.31

14415.24
18001.29

v)

1600 mm

9458.27

28220.80

vi) 1700 mm

11375.7
5

32092.47

Supplying and fixing PVC


water stop 190 mm wide.

44.50

332.93

600 mm

If plaster is
done to
smoothen
the surface it
should not
be paid for
extra.

5.6 to
5.9

5-2

Crushing
strength of
152x152x
152mm cube
at 28 days of
4000 psi or
compressive
strength of
3600 psi for
15x30 cm
test cylinder.

5.7
WCSR-2013 (Zone-2)

SECTION 5 CONCRETE

Sr.
Description
No.
1
2
6. Supplying and fabrication
of Intermediate grade
deformed reinforcement
for R.C.C. in slabs,
beams, columns and pile
caps, including cutting,
bending laying in position
including cost of binding
wire;
a. 40,000 psi (276 MPa)
yield
b. 60,000 psi (420 MPa)
yield
7.

Unit
3

Rate (Rs)
Labour Composite
4
5

kg

14.34

110.48

kg

14.34

118.16

Supplying and fabrication


of intermediate grade
deformed reinforcement
for R.C.C. piles including
cutting, bending, laying in
position, welding and
fastening including cost
of binding wire;
kg

25.72

144.49

kg

25.72

152.17

8.

Providing
and
fixing
R.C.C.
pre-stressed
battens 60mm x 150mm
x 2 m)

no

105.01

773.10

9.

Construction of precast
cement concrete solid or
face blocks masonry
(1:4:8) including cost of
template in mortar 1:6.

10.

11.

WAPDA

Remark
7

-do-

a. 40,000 psi (276 MPa)


yield
b. 60,000 psi (420 MPa)
yield

a) foundation & plinth


b) super structure

Specifi
cation
6
5.8

8.1,2.1

5.10

cum
cum

1710.90
2084.84

4854.84
6913.66

Construction of precast
cement concrete solid or
face blocks masonry
(1:3:6) including cost of
template in mortar 1:6.

-do-

a) foundation & plinth


b) super structure

cum
cum

1433.87
1754.64

5348.40
5669.16

Precast cement concrete


solid or face blocks
(1:2:4) including cost of
templates
and

cum

1651.43

7359.85

5-3

-do-

WCSR-2013 (Zone-2)

SECTION 5 CONCRETE

Sr.
No.
1

Description

Unit

construction
thereof.

of

walls

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

12.

Precast cement concrete


hollow blocks (1:2:4)
including
cost
of
templates
and
construction of
walls
thereof.

cum

3624.90

7058.15

5.10

13.

Providing
and
fixing
ornamental cement jalli
50mm
thick
(1:2:4)
without steel.

sqm

409.62

835.04

-do-

14.

Extra labour for laying


concrete
plain
or
reinforced.
a) Above 6 upto 12m,
height.
b) For every additional
3m height.

cum

838.30

cum

209.43

Extra labour for work of


weirs,
road
bridges,
syphons
and
similar
concreting
in
super
structure.

cum

209.43

16.

Reinforced
cement
concrete spout including
fixing in position (150 x
125 x 800 mm).

each

380.69

17.

Making
holes
upto
450mm deep in cement
concrete or in stone
masonry
walls
and
repairing. (75mm )

per
hole

1065.93

5.5

18.

Skipping
concrete
including mixing.

cum

2947.43

5.6 &
19.3 K

19.

Nicking concrete surface.

sqm

50.19

20.

Preparing, watering and


ramming
surface
for
laying concrete (for head
works only).
sqm
sqm
sqm

41.11
66.21
19.80

WAPDA

Horizontal floor
Glacis and crest
Inverted filters

5.1 &
5.6

15.

a)
b)
c)

Remark

5-4

-do-

742.95

5.6,
5.10
&8.9

5.6.3

WCSR-2013 (Zone-2)

SECTION 5 CONCRETE

Sr.
Description
No.
1
2
21. Erection and removal of
centering for R.C.C. or
plain cement concrete
work:
i) Horizontal
ii) Vertical

Unit
3

Rate (Rs)
Labour Composite
4
5

sqm
sqm

427.77
491.85

485.08
549.16

24.37

173.27

Specifi
cation
6
5.6.2 &
5.6.17

22.

Providing and fixing 150


mm wide G.I sheet 18
SWG
stopper
to
expansion joint.

23.

Grouting
cement
concrete between the
grooves
of
gates
including shuttering.

cum

2443.52

20.8

24.

Chisel dressing complete


surface on sides of
grooves.

sqm

25.10

-do-

25.

Making pre-cast cement


concrete solid blocks
(1:2:4)
with
molding
machine.

cum

506.12

6140.97

26.

Providing and installation


of
saddle
(gutka)
60x60x230mm in 1:2:4
concrete with angle iron
40x40x5mm, Steel wire
SWG18 and painting
complete.

sqm

802.39

1497.22

27.

Concrete,
1:2:4
by
Batching Plant, including
production, haulage and
Placing without formwork.

cum

28.

Roller
Compacted
Concrete
containing
typical, bedding mixtures
of 360 to 460 kg/cum of
cement 170 to 220
kg/cum of fly ash and
4.75 to 50 mm size of
aggregate (ACI 207.5R89)

cum

WAPDA

Remark
7

5.7

12574.95

Composite
rate would
be 25% to
50% less
than rate of
normal
conventional
concrete.

5-5

WCSR-2013 (Zone-2)

SECTION 6 BRICK WORK

SECTION- 6

BRICK WORK
1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.

Sr.
Description
No.
1
2
1. Bricks work in foundation
and plinth in Cement
sand mortar. Ratio:
1:2
1:3

2.

3.

4.

5.

WAPDA

Unit
3

Rate (Rs)
Labour Composite
4
5

cum
cum

1511.12
1511.12

7132.69
6774.29

1:4

cum

1511.12

6559.05

1:5

cum

1511.12

6404.17

1:6

cum

1511.12

6315.38

Bricks work in ground


floor (including striking of
joints) in Cement sand
mortar. Ratio:
1:2

cum

1957.55

7579.11

1:3

cum

1957.55

7235.37

1:4

cum

1957.55

7005.47

1:5
1:6

cum
cum

1957.55
1957.55

6862.32
6761.81

Specification
6
6.1 to
6.5

-do-

Add extra labour in item


No.2 for brick work in:
First floor

cum

291.22

Second floor

cum

665.17

Third floor

cum

1038.18

4th and subsequent floor

cum

1681.65

Remark
7
Only first
class bricks
shall be
used against
respective
Items of this
section.
Standard
size of bricks
225 x 113 x
75 mm (9 x
4 x 3).

-do-

Bricks work other than


building including striking
of joints upto
3.0 m
height in Cement sand
mortar. Ratio:
1:2
1:3

-do-

cum
cum

1764.04
1764.04

7385.60
7027.21

1:4

cum

1764.04

6811.96

1:5

cum

1764.04

6668.82

1:6

cum

1764.04

6568.30

Add extra labour in item


No.4 for every 3.0 meters
additional height.

cum

291.22

6-1

-do-

WCSR-2013 (Zone-2)

SECTION 6 BRICK WORK

Sr.
No.
1

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Description

Unit

6.

Providing and laying tile


coping 300 x 150 x
40mm in 1:3 Cement
sand mortar including
13mm thick plaster 1:4
complete.

94.19

211.15

-do-

7.

Providing and laying tile


coping 300 x 150 x
40mm in 1:3 cement
sand mortar.

18.71

113.71

-do-

8.

Extra labour for arch


work in brick masonry
including
labour
for
centring and decentring.

cum

746.96

9.

Extra labour for brunt


brick work in wells or any
other circular masonry.

cum

409.90

10.

Extra labour for profile


and flared walls.

cum

537.53

11.

Extra labour for brunt


brick work in piers and
abutment;
cum
cum

373.94
642.54

12.

Reinforced brick work in


lintel/slab laid in 1:3
cement sand mortar
including
all
labour,
material, forms, lifting
and shuttering, etc. but
excluding
cost
and
labour
of
steel
reinforcement.

cum

4874.69

13.

Dressing or chamfering
of bricks

WAPDA

6.6

620.15

-do-

6.7
-do-

i) From 3 to 6 m height
ii) Above 6 m height

14.

Remark

10153.24

6.1 to
6.5

-do-

a) Special architectural
shape.

no

30.85

b) For circular sewer,


manholes and vent,
shafts pertaining to
sewer works and out
lets
of
Irrigation
channels.

no

21.56

6.14

Perforated brick walling


115 mm thick in ground
floor in cement sand
mortar.
6-2

WCSR-2013 (Zone-2)

SECTION 6 BRICK WORK

Sr.
No.
1

Description

Unit

1:2
1:3
1:4
1:5
1:6

sqm
sqm
sqm
sqm
sqm

Ratio:

15.

18.

WAPDA

sqm
sqm
sqm
sqm

6.1& 6.5

sqm
sqm
sqm
sqm
sqm

447.02
447.02
447.02
447.02
447.02

1306.28
1251.55
1218.97
1196.83
1181.57
-do-

sqm
sqm

66.65
202.84

Third floor

sqm

357.29

sqm

512.08

Bricks walling laid in 1:3


cement sand mortar
reinforced with
25mm
wide 18 gauge hoop iron.
i) 115mm thick walling
with hoop bonding
150mm apart.

44.12
101.25
157.79
256.04

First floor
Second floor
subsequent

Remark

6.14

Add extra labour in item


No.16 for brick work in.

4th
and
floors

Specifi
cation
6

729.22
701.86
685.53
675.02
667.68

Perforated brick walling


230mm thick in ground
floor in cement sand
mortar. Ratio:
1:2
1:3
1:4
1:5
1:6

17.

304.06
304.06
304.06
304.06
304.06

Add extra labour in item


No.14 brick work in:
First floor
Second floor
Third floor
4th
and
subsequent
floors

16.

Rate (Rs)
Labour Composite
4
5

6.8

sqm

202.38

838.30

ii) 115mm thick walling


with hoop bonding
300mm apart.

sqm

202.38

837.42

iii) 75mm thick walling


with hoop bonding
150mm apart.

sqm

158.30

593.87

iv) 75mm thick walling


with hoop bonding
300 mm apart.

sqm

161.66

596.35

6-3

WCSR-2013 (Zone-2)

SECTION 6 BRICK WORK

Sr.
No.
1
21.

Description

Unit

2
Eaves
brick
molded
weathered and throated
with back bricks or drip
course cornice in 1:3
cement sand mortar.

i) 75 mm
ii) 115 mm
22.

Laying
dressed
or
molded brick cornice in
1:6 cement sand mortar,
plastering or pointing
complete.
i) One brick
ii) Two bricks
iii) Three bricks
iv) Four bricks

m
m

Rate (Rs)
Labour Composite
4
5

91.54
105.25

m
m
m
m

105.25
153.98
206.01
259.22

Scraping or cleaning
bricks dismantled from
masonry.

no.

0.93

24.

Supplying and filling


sand under floors or
plugging in wells

cum

67.67

25.

Damp proof course with


(cement,
sand
and
shingle concrete 1:2:4)
including 2 coats of
asphaltic mixture.

196.06
256.62

161.47
309.47
485.84
662.72
6.1 to
6.5
712.62

9.6.4/
19.4(L)

20.8

sqm
sqm
sqm

208.00
208.00
217.79

505.86
560.27
739.05

26.

Vertical
damp
proof
course of 20 mm thick
cement plaster 1:2 with
bitumen at 1 kg per
sqm.

sqm

193.77

404.99

-do-

27.

Constructing cavity wall


consisting of 115mm
thick
external
and
230mm internal brick wall
laid in (1:4) and (1:6)
cement sand mortar
respectively
including
providing
and
fixing
9.5mm tie bars 40mm
thick thermopore sheet,
weep holes and air vent
holes complete as per

cum

2001.05

7576.89

20.8

WAPDA

Remark

6.9

23.

a) 40 mm
b) 50 mm
c) 75 mm

Specifi
cation
6
6.1 to
6.5

6-4

WCSR-2013 (Zone-2)

SECTION 6 BRICK WORK

Sr.
No.
1

Description

Unit

Drawing No.
301-5-B/63

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

CDO(W)

28.

Reinforced brick work


laid in 1:3 cement sand
mortar in foundation and
plinth excluding the cost
of reinforcement and its
fabrication.

cum

1512.05

6775.75

20.8

29.

Reinforced brick work


laid in 1:3 cement sand
mortar in ground and
subsequent
floors
excluding
cost
of
reinforcement and its
fabrication.

cum

2048.32

7312.02

-do-

WAPDA

Remark

6-5

WCSR-2013 (Zone-2)

SECTION 7 STONE MASONRY

SECTION- 7

STONE MASONRY
1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.

Sr.
No.
1

Description

Unit

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Remark
7

FOUNDATION & PLINTH


1.

Random Rubble masonry


uncoursed).
a) Dry

cum

1284.49

3179.51

1:3

cum

2466.09

6238.53

ii) 1:4
iii) 1:6

cum
cum

2466.09
2466.09

5915.90
5546.47

iv) 1:8

cum

2466.09

5342.26

b) In
cement
mortar, Ratio:
i)

2.

7.3 &
7.4

sand

Coursed
Rubble,
masonry
including
hammer dressing.
a) Dry

7.3 &
7.11
cum

1612.59

3507.61

b) In
cement
mortar, Ratio:
i) 1:3

cum

2466.09

6238.53

ii) 1:4

cum

2466.09

5915.90

iii) 1:6

cum

2466.09

5546.47

iv) 1:8

cum

2466.09

5342.26

sand

SUPER STRUCTURE
(Ground floor or 6.0m
height of uncovered wall)
3.

Random Rubble masonry


(uncoursed).
a) Dry

cum

1449.01

3344.02

b) In
cement
mortar, Ratio:
i) 1:3
ii) 1:4

cum
cum

2681.88
2681.88

6454.33
6131.69

iii) 1:6

cum

2681.88

5762.26

iv) 1:8

cum

2681.88

5558.05

cum

414.05

sand

c) Add extra labour in


item No.3:
First floor
WAPDA

7.3 &
7.4

7-1

WCSR-2013 (Zone-2)

SECTION 7 STONE MASONRY

Sr.
No.
1

4.

2
Second floor
Third floor

3
cum
cum

Rate (Rs)
Labour Composite
4
5
938.73
1284.49

4th and subsequent


floors

cum

2354.87

d) Extra labour for every


1.50 m additional
height of uncovered
wall.

cum

373.94

Description

Unit

Coursed
Rubble,
masonry
including
hammer dressing.
a) Dry

1882.12

3777.14

i) 1:3
ii) 1:4

cum
cum

3114.40
3114.40

6810.63
6523.81

iii) 1:6

cum

3114.40

6195.36

iv) 1:8

cum

3114.40

6020.21

cum
cum

414.05
938.73

cum

1284.49

cum

2354.87

cum

373.94

Third floor
4th and subsequent
floors
d) Extra labour for every
1.5m
additional
height of uncovered
wall.
Ashlar block in course or
scabbled
Masonry
including dressing etc.,
a) In
cement
mortar, Ratio:
i)

sand

c) Add extra labour in


item No.4:
First floor
Second floor

5.

Remark

7.3 &
7.11
cum

b) In
cement
mortar, Ratio:

Specifi
cation
6

7.3 &
7.6

sand

1:3

cum

8356.56

13177.04

ii) 1:4
iii) 1:6

cum
cum

8356.56
8356.56

12961.79
12718.13

First floor
Second floor

cum
cum

414.05
938.73

Third floor

cum
cum

1473.15
2354.87

b) Add extra labour in


item No.5:

4th and subsequent


floors

WAPDA

7-2

WCSR-2013 (Zone-2)

SECTION 7 STONE MASONRY

Sr.
Description
No.
1
2
6. Ashlar
fine
masonry
including dressing etc.
a) In
cement
sand
mortar, Ratio:

Unit
3

Rate (Rs)
Labour Composite
4
5

i) 1:3
ii) 1:4

cum
cum

15723.39
15723.39

20862.20
20754.81

iii) 1:6

cum

15723.39

20634.27

cum

414.05

Second floor
Third floor

cum
cum

938.73
1473.15

4th and subsequent


floors.

cum

2354.87

cum

1075.06

b) Add extra labour n


item No.6:
First floor

Specifi
cation
6
7.3 &
7.7

Remark
7

MISCELLANEOUS
DRESSING STONES ETC
7.

Extra labour for arch


work in stone masonry
including centering and
de-centering etc.

8.

Moulding and dressing


stones etc.

9.

7.3 &
7.5

a) Extra for coping and


caps, etc.

cum

5908.65

b) Cornice and string


course.

cum

5908.65

Dressing stone:
a) Hammer dressed
b) Rough tooled dressed
c) Chisel dressed
d) Fine dressed

7.3 &
7.12

sqm
sqm
sqm
sqm

659.65
1255.82
1520.06
3120.61

8160.55

7.5 &
7.10

10.

Sand grouting in stone


apron with high pressure
hose.

sqm

89.17

178.29

7.14

11.

Grouting stone pitching


or apron in 1:3 cement
mortar.

sqm

257.57

639.37

7.14 &
7.15

12.

Levelling and dressing


stone filling under blocks
and grouting with shingle.

sqm

89.17

245.53

7.3 &
7.14

13.

Grouting voids between


blocks with bajri.

cum

291.22

634.87

-do-

WAPDA

7-3

WCSR-2013 (Zone-2)

SECTION 7 STONE MASONRY

Sr.
No.
1

Unit

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

14.

Stone filling dry hand


packed as filling behind
retaining walls or in
pitching and aprons.

cum

537.53

1739.00

7.3 &
7.14

15.

Grouting stone filling or


pitching with bajri.

cum

261.64

873.89

-do-

16.

Breaking stone ballast


screened and stacked:
a) 50 mm
b) 40 mm
c) 25 mm
d) 13 mm
e) 13 to 6 mm

7.3
cum
cum
cum
cum
cum

733.29
838.30
942.72
1257.16
2094.87

17.

Breaking
stone
into
spawls and stacking.

cum

314.44

-do-

18.

Screening and stacking


stone ballast shingle or
bajri etc.

cum

209.43

-do-

19.

Washing ballast,
shingle etc.

bajri

cum

209.43

-do-

20. Crushing stone ballast and


stacking within 100 m.

cum

628.28

-do-

21.

Stone
pitching
with
hammer dressed stones
on surface laid in courses
including
carriage
of
material within 100 m.

cum

1786.66

3848.53

7.3 &
7.15

22.

Stone
pitching
hand
packed
with
surface
levelled off to the correct
section with hammer
dressed stone and voids
filled in 1:8 cement
mortar in floors of bridges
and along banks and in
aprons etc. including
100 m lead.

cum

2077.88

6191.18

-do-

23.

Removing, stone and


repitching, hand packed
on slopes after making
good damaged slope.

cum

792.80

792.80

-do-

24. Collecting and stacking


boulders from nullah
beds or loose shale from

cum

418.86

418.86

-do-

WAPDA

Remark

7-4

WCSR-2013 (Zone-2)

SECTION 7 STONE MASONRY

Sr.
No.
1

25.

26.

Description

Unit

any other
100 m.

site,

within

Rate (Rs)
Labour Composite
4
5

Stone pitching for top


Layer only:

Specifi
cation
6

7.3 &
7.15

a) On slope

cum

1206.34

3268.21

b) On horizontal level

cum

1058.02

3119.89

Laying stone or spawl


filling:

Top layer
mean
350mm to
450mm thick
stone
pitching
layer.

-do-

a) On slope

cum

291.22

2181.27

b) On horizontal level

cum

239.01

2129.06

27.

Providing
and
fixing
150mm thick dressed
stone pavement on walk
way properly dressed set
in cement mortar 1:4
curing etc. complete.

sqm

420.08

941.81

7.3 &
7.14

28.

Supply and spreading of


crushed stone/water born
gravel of 20mm size.

cum

105.11

2145.95

-do-

WAPDA

Remark

7-5

WCSR-2013 (Zone-2)

SECTION 8 ROOFING

SECTION- 8

R O O F I N G
1.

Rates for all finished works shall include the removal of surplus debris, unused
material and by products.

2.

The composite rates shall constitute compensation for the completed items of works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished works.

Sr.
Description
No.
1
2
1. Brick tiles 300 x 150 x
50mm roofing consisting
of 13 mm thick cement
plaster 1:6 with 1.75 kg.
of hot bitumen coating
sand blinded provided
over tiles laid in 1:6
cement mortar including
1:2
cement
pointing
under-neath
of
tiles
complete including curing
etc.
2.

Brick tiles 225 x 113 x


38mm laid over 100mm
earth & 25mm mud
plaster
grouted
with
cement sand 1:3 on top
of
RCC
roof
slab
provided with 1.75 kg.
bitumen coating sand
blinded.

3.

Jack arch roofing 115mm


thick laid in 1:5 cement
mortar
including
an
average depth of 100mm
cement
concrete
in
haunches
and
over
crown with 100mm earth
& mud plaster soffits of
arches cement plastered
1:6,
13mm
thick.
The rate also includes
bitumen coating centring,
laying skew bricks in
cement sand mortar (1:3)
and encasing exposed
flanges of the joists with
fine cement concrete
1:2:4
using
stone
aggregate:
Cement
concrete
in
haunches 1:3:6

WAPDA

Unit
3
sqm

sqm

Rate (Rs)
Labour Composite
4
5
633.29
1094.25

253.03

718.82

Specifi
cation
6
8.1 &
8.2

888.00

8-1

8.11

8.3, 8.4
& 8.5

sqm

Remark

For steel
part & its
erection etc,
items under
Iron work Misc. of the
Composite
Schedule of
Rates be
referred.

2282.56

WCSR-2013 (Zone-2)

SECTION 8 ROOFING

Sr.
No.
1
4.

Description

Unit

Jack arch roofing 115mm


thick laid in 1:5 cement
mortar
including
an
average depth of 100mm
cement
concrete
in
haunches
and
over
crown with 13mm cement
plaster, 1:6 on top
(except earth filling and
mud plaster) soffit of
arches cement plastered.
The rate also includes
bitumen
coating,
centring, laying skew
bricks in cement sand
mortar
(1:3)
and
encasing
exposed
flanges of the joists with
fine cement concrete
1:2:4
using
stone
aggregate.
Cement
concrete
in
haunches 1:3:6.

Rate (Rs)
Labour Composite
4
5

sqm

717.19

Specifi
cation
6
8.3, 8.4
& 8.5

Extra for vaulted jack


arch roofing.

sqm

153.93

6.

Jack arch roofing of


shingle
&
cement
concrete (1:3:6) 115mm
thick at crown, with
13mm cement plaster
including
cost
of
supplying erecting and
dismantling centring.

sqm

742.70

1218.96

-do-

7.

Two coats of bitumen laid


hot using 1.66 kg. per
sqm over roof & blinded
with sand at 0.003 cum
per sqm

sqm

64.07

110.66

8.11

8.

Corrugated
galvanized
iron sheets fixed with G.I.
bolts, nuts limpets and
bitumen washer, windties
complete in all respects
without valleys & ridges:

WAPDA

7
For steel
part & its
erection etc,
items under
Iron work Misc. of the
Composite
Schedule of
Rates be
referred

2047.36

5.

a) 20 S.W.G
b) 22 S.W.G
c) 24 S.W.G

Remark

-do-

8.7

sqm

154.85

1874.02

sqm
sqm

154.85
154.85

1650.85
1399.68

8-2

WCSR-2013 (Zone-2)

SECTION 8 ROOFING

Sr.
Description
No.
1
2
9. Plain galvanized iron
sheets of 22 S.W.G. rain
water
down
pipe
including clamps and
fixed in place:
a) 100 mm
b) 125 mm
10.

Plain galvanized iron


sheet flashing 22 gauge

11.

Cast iron rain water down


pipe fixed in place
excluding heads & shoes
but including clamps etc:
a) 100 mm
b) 75 mm

12.

Rain water down pipe


cast iron heads fixed in
place including cost of
clamps hold fast and
painting:
a) 100 mm
b) 75 mm

Unit
3

Rate (Rs)
Labour Composite
4
5

m
m

236.32
236.32

1173.33
1465.80

sqm

960.72

1620.17

Specifi
cation
6
8.10

-do-

169.19

2229.10

169.19

1864.56
-do-

each
each

208.94
208.94

767.29
671.02

Shoes, bends or offsets


for cast iron rain water
down pipe including fixing
and painting.

each

69.60

910.62

8.1

14.

Plain G.I. sheet iron


spouts fixed in place
including painting (700
mm length & 150mm
width).

each

236.32

347.78

8.9 &
8.10

15.

13mm
thick
deodar
ceiling complete including
sawing planning and
fixing.

sqm

405.32

3129.08

8.12

16.

Flat sheet roof with


galvanized iron plain
sheets including battens
rolls screws clips etc.;
a) 22 B.W.G.
b) 24 B.W.G.

WAPDA

Asbestos
cement
corrugated sheet roofing
including necessary over
laps & G.I. hook, bolts,
nuts, screws, washers &

-do-

13.

17.

Remark

8.8

sqm
sqm

392.16
392.16

1066.99
992.71

sqm

181.10

1404.94

8-3

-do-

WCSR-2013 (Zone-2)

SECTION 8 ROOFING

Sr.
No.
1

Description

Unit

bitumen washers,
(excluding valleys
ridges etc.).

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

etc.
and

18.

Extra labour for erection


of G.I. sheets, flat sheets
or asbestos sheet roofing
above 6.00m height in
difficult position including
lifting with care & special
scaffolding along live
electric wires.

sqm

40.82

19.

Asbestos cement sheet


ridges & valleys 6mm
thick.

63.45

20.

Plain galvanized iron


sheet ridging including
fixture, timber for ridge
roll and ridge sheeting:

8.8

394.19

-do-

8.7

a) 150mm lap & 450mm


over all of 22 gauge
G.I. sheet ridging.

252.28

1970.97

b) 230mm lap & 600mm


over all of 24 gauge
G.I. sheet ridging.

252.28

2048.73

c) 300mm lap & 750mm


over all of 22 gauge
G.I. sheet ridging.

252.28

2261.28

21.

Plain 22 gauge G.I. sheet


gutter
semi
circular
200mm .

143.38

494.27

22.

Making
ventilators.

masonry

each

1522.75

2111.08

23.

Earthen ware
ventilators.

syphon

each

169.03

206.23

24.

Single layer of building


paper/2-ply
bitumen
paper for floors etc. laid
over two coats of bitumen
hot using 1.66 kg. per
sqm blinding with sand at
0.003 cum per sqm.

sqm

71.79

532.49

8.1 &
8.11

25.

Double layer of building


paper laid over 2 coats of
hot bitumen PB-3 or PB-4
for floors etc. using 1.66
kg. bitumen per sqm.

sqm

75.35

821.97

-do-

WAPDA

Remark

8-4

8.1

WCSR-2013 (Zone-2)

SECTION 8 ROOFING

Sr.
Description
No.
1
2
26. Polythine sheet 0.2 mm
thick laid over two coats
of bitumen using 1.66 kg.
bitumen hot per sqm over
floors & DPC etc.

Unit
3
sqm

Rate (Rs)
Labour Composite
4
5
71.79
284.81

Specifi
cation
6
8.1&
8.11

27.

3 ply bitumenized paper


laid over two coats of hot
bitumen PB-3 or PB-4,
using 1.66 kg. bitumen
per sqm.

sqm

75.35

536.05

-do-

28.

False ceiling comprising


plain asbestos cement
sheet
perforated
at
corners fixed with screws
on wooden frame having
deodar beading 50 x
13mm excluding cost of
wooden frame.

sqm

39.21

575.01

8.1, 8.8
& 11.1

29.

False ceiling comprising


soft board 13mm thick
fixed with screws on
wooden
frame
with
deodar wood beading 50
x 13mm excluding cost of
wooden frame.

sqm

81.68

1327.93

8.1 &
11.1

30.

False ceiling comprising


thermopore sheet 13mm
thick fixed with screws on
wooden
frame
with
deodar wood beading 50
x 13mm excluding cost of
wooden frame.

sqm

98.02

1065.31

-do-

31.

False ceiling comprising


thermosole 13mm thick
fixed with screws on
wooden
frame
with
deodar wood beading 50
x 13 mm excluding cost
of wooden frame.

sqm

98.02

974.10

-do-

32.

False
ceiling
frame
comprising partal wood
50 x 75mm including
termite proofing.

sqm

110.91

1355.86

8.1, 8.8
& 11.1

33.

False ceiling comprising


iron L & T Section and
Gypsum Board complete
in all respect.

sqm

114.08

770.85

WAPDA

8-5

Remark
7

WCSR-2013 (Zone-2)

SECTION 9 FLOORING

SECTION - 9

F L O O R I N G
1.

Rates for all finished works shall include the removal of surplus debris, unused
material and by products.

2.

The composite rates shall constitute compensation for the completed items of works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished works.

Sr.
No.
1

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Description

Unit

1.

Murum flooring consisting


of 25mm layer of fine
powder or flakey variety
of Murum laid over
150mm good hard layer
of Murum spreaded over
230mm thick sub-base of
hand packed rubble or
broken bricks properly
watered
&
rammed
provided
over
well
rammed earth.

sqm

273.86

506.72

9.1 &
9.3

2.

Grouting 115mm brick


with cement sand mortar
1:5.

sqm

114.27

162.63

9.5

3.

Flat brick flooring laid in


1:6 cement sand mortar
over a bed of 20mm
cement mortar 1:6.

sqm

202.84

596.47

9.4 &
9.5

4.

Brick tiles (Size 300 x


150 x 50mm) laid in 1:6
cement mortar over a
bed of 20mm thick
cement mortar 1:6.

sqm

202.84

385.72

9.7

5.

Brick tiles (230 x 115 x


40mm) laid in 1:3 cement
mortar over a bed of
20mm
thick
cement
mortar 1:6.

sqm

227.94

505.27

-do-

6.

Colour Cement tiles (200


x 200 x 20 mm) laid flat in
1:2 cement mortar over a
bed of 20mm thick
cement mortar 1:2.

sqm

298.56

1741.73

-do-

7.

Cement concrete tiles


laid flat in 1:2 cement
mortar over 20mm thick
bed of cement mortar
1:2:
a) 300 x 300 x 25 mm

WAPDA

Remark
7
Bricks used
in this
Section shall
are of first
class.

-do-

sqm

298.56
9-1

775.55
WCSR-2013 (Zone-2)

SECTION 9 FLOORING

Sr.
No.
1

Description

Unit

Rate (Rs)
Labour Composite
4
5

b) 225 x 225 x 20 mm

sqm

298.56

850.46

c) 200 x 200 x 20 mm

sqm

298.56

970.31

d) 150 x 150 x 20 mm

sqm

298.56

1309.91

sqm

298.56

1741.73

8.

Coloured cement tiles


(200 x 200 x 20 mm) of
approved dark shade laid
flat in 1:2 cement mortar
over a bed of 20mm thick
cement mortar 1:2.

9.

Topping
of
cement
concrete (1:2:4) including
surface
finishing
&
dividing into panels:
a) 25 mm

sqm

162.97

280.07

b) 40 mm

sqm

197.98

370.75

c) 50 mm

sqm

229.42

463.16

d) 75 mm

sqm

267.98

611.96
246.53

Add extra in cement floor


topping if finished with
pigment and polishing.

sqm

82.23

11.

Extra labour for each


storey above ground for
mosaic, conglomerate or
tiles, stone and wooden
floor.

sqm

75.94

12.

Flag stone flooring in


cement mortar 1:2 over
20mm bed of cement
mortar (1:2) for platforms
and floors etc:

WAPDA

Remark
7

9.7

9.8

10.

13.

Specifi
cation
6

Cost of glass
strip for
paneling is
not included
in rates.

-do-

-do-

9.1

a) 50 mm

sqm

454.64

861.57

b) 75 mm

sqm

454.64

874.96

Asphalt flooring including


preparation of proper
base re-melting, setting
out & finishing complete:

9.13

a) 6 mm

sqm

103.90

320.07

b) 13 mm

sqm

149.29

579.94

c) 25 mm

sqm

176.68

1042.69

9-2

WCSR-2013 (Zone-2)

SECTION 9 FLOORING

Sr.
No.
1
14.

15.

16.

Description

Unit

Mosaic
flooring
consisting of mosaic
topping of one part of
cement to two parts of
marble chips laid over
25mm thick flooring of
1:2:4 cement concrete
including
rubbing
&
polishing complete:
sqm

710.65

1065.58

b) 13 mm (with grey
cement)

sqm

729.64

1138.53

c) 10 mm (with white
cement)

sqm

710.65

1116.71

d) 13 mm (with white
cement)

sqm

729.64

1197.34

Flooring comprising of
mosaic marble chips
cement tiles of approved
shade laid in cement
mortar
1:2
including
finishing complete:
sqm

369.51

830.02

b) White

sqm

369.51

768.78

Flooring comprising of
glazed tiles 6mm thick
laid in white cement
mortar 1:2 over 20mm
thick cement mortar 1:2
complete:
sqm

292.70

1210.58

b) Coloured

sqm

292.70

1347.79

sqm

72.06

85.31

White marble flooring fine


dressed on the surface
without winding set in
cement mortar 1:2 laid
over
20
mm
thick
cement
mortar
1:2
including
rubbing
&
polishing:

7
Cost of glass
strip for
paneling is
not included
in rates.

-do-

a) White

18.

Remark

9.7

a) Grey

Rubbing and polishing


old mosaic floor.

Specifi
cation
6
9.9

a) 10 mm (with grey
cement)

17.

WAPDA

Rate (Rs)
Labour Composite
4
5

9.14
9.7

a) 20mm

sqm

947.39

4571.12

b) 25mm

sqm

947.39

4975.46

9-3

WCSR-2013 (Zone-2)

SECTION 9 FLOORING

Sr.
No.
1
19.

Description

Unit

Rate (Rs)
Labour Composite
4
5

Shisham / Deodar wood


boarding or strips flooring
19mm thick (sawn to
required size) tongued &
grooved
or
splayed
rebated fixed with brass
screws on deodar wood
battens 40x50 mm size
placed at 300 mm centre
to centre including 2
coats of bitumen laid hot
on the base:

Specifi
cation
6

sqm

1276.74

5827.67

b) Deodar

sqm

958.15

7983.28

20.

Teak wood boarding or


strips flooring 13mm thick
(sawn to required size)
tongued
&
grooved
screwed on deodar wood
battens 40x50 mm size
placed at 300 mm centre
to centre including 2
coats of bitumen laid hot
on the base.

sqm

1276.74

7374.16

-do-

21.

Shisham wood block


flooring 25mm thick cut to
required size fixed on a
layer of asphalt bitumen
laid on base.

sqm

958.15

5237.63

-do-

22.

Teak wood block 25mm


thick cut to required size
fixed on a layer of asphalt
bitumen laid on base.

sqm

1276.74

5181.45

9.11

23.

Paving of hard wood


25 mm thick laid on edge
in coal tar and asphalt:

WAPDA

9.11

a) Shisham

24.

Remark

-do-

a) Shisham

sqm

388.12

3008.96

b) Kikar

sqm

388.12

1820.09

Tiles skirting laid in 1:2


cement
mortar
over
20mm
thick
cement
mortar
1:2
including
cement washing & filling
joints complete:

9.7

a) Cement

sqm

330.60

1122.32

b) Mosaic

sqm

375.45

2005.85

9-4

WCSR-2013 (Zone-2)

SECTION 9 FLOORING

Sr.
Description
No.
1
2
25. Grey cement skirting or
dado
10mm
thick
including rounding of
corners and straightening
of top edge finished to
smooth surface after
plastering:

26.

Rate (Rs)
Labour Composite
4
5

a) 1:2 mix

sqm

366.90

444.57

c) 1:3 mix

sqm

366.90

431.48

d) Extra if skirting or
dado is finished with
pigment
of
any
colour.

sqm

43.13

45.64

Glazed tiles dado 6mm


thick jointed in white
cement & laid over 1:2
cement
sand
mortar
20mm thick including
finishing:
a)

White

b) Coloured
27.

Unit

Remark
7

9.7

sqm

601.25

2050.77

sqm

601.25

2137.88

Mosaic dado or skirting


with one part of cement &
2 parts of marble chips
laid over 13mm thick
cement
plaster
1:3
complete with finishing
and polishing:

9.9

a) 10 mm (with grey
cement)

sqm

656.31

934.48

b) 13 mm (with grey
cement)

sqm

656.31

1009.93

c) 10 mm (with white
cement)

sqm

656.31

981.78

d) 13 mm (with white
cement)

sqm

656.31

1078.90

28.

Vinyle floor tiles laid with


adhesive 300 x 300 x 5
mm
size
on
firm
foundation.

sqm

146.64

715.98

29.

Flooring comprising of
first class Granite glazed
tiles with 13 mm thick
white bond cement.

sqm

376.21

1896.79

WAPDA

Specifi
cation
6
9.8

9-5

9.12

WCSR-2013 (Zone-2)

SECTION 9 FLOORING

Sr.
No.
1

Description

Unit

30.

Providing and laying Tuff


tile over 100 mm thick
sand complete.

sqm

31.

Glass strips for dividing


the flooring into panels:

WAPDA

Rate (Rs)
Labour Composite
4
5
62.47

Specifi
cation
6

Remark
7

683.04

9.9

a) 25 mm

64.16

76.32

b) 40 mm

64.16

78.31

c) 50 mm

64.16

80.70

d) 75 mm

64.16

82.30

9-6

WCSR-2013 (Zone-2)

SECTION 10 SURFACE RENDERING

SECTION - 10

SURFACE RENDERING

(Plastering, Pointing, White Washing, Colour Washing and Distempering etc.)


1.
2.

Sr.
No.
1
1.

Rates for all finished works shall include the removal of surplus debris, unused
material and by products.
The composite rates shall constitute compensation for the completed items of works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.
Description

Unit

2
Cement neru plaster 1:2
(cement & sand).

Rate (Rs)
Labour Composite
4
5

a) 6 mm
b) 13 mm

sqm
sqm

155.38
155.38

223.99
244.83

2.

Stucco cement plaster


1:2:4 (cement sand &
shingle) 50 mm thick.

sqm

375.07

653.64

3.

Cement plaster (1:2) upto


1st floor height:
a) 10 mm
b) 13 mm
c) 20 mm

4.

5.

sqm
sqm
sqm

155.38
155.38
196.49

215.55
233.05
316.25

6.

Applying floating coat of


cement one (1) mm thick.

7.

Cement pointing flush


upto 1st floor height in
ratio:

sqm
sqm
sqm

155.38
155.38
196.49

7
Add extra
10%, 30% &
50% above
labour rates
only or 5%,
15% & 20%
on the
composite
rates for
2nd, 3rd, 4th
and
subsequent
floors
respectively.

198.12
212.56
282.55
-do-

sqm
sqm
sqm

155.38
155.38
196.49

193.42
204.10
272.51

sqm

97.83

121.08

-do-do-

a) 1:2
b) 1:3

sqm
sqm

155.38
155.38

200.06
190.07

8.

Cement pointing 1:2 flush


on floor.

sqm

114.27

158.94

9.

Cement pointing struck


joints on walls in ratio:
a) 1:2

WAPDA

Remark

-do-

Cement plaster (1:4) upto


1st floor height:
a) 10 mm
b) 13 mm
c) 20 mm

-do-

-do-

Cement plaster (1:3) upto


1st floor height:
a) 10 mm
b) 13 mm
c) 20 mm

Specifi
cation
6
10.1,
10.2 &
10.6

-do-do-

sqm

180.48
10 - 1

225.15
WCSR-2013 (Zone-2)

SECTION 10 SURFACE RENDERING

Sr.
No.
1
10.

b) 1:3

Description

Unit

3
sqm

Rate (Rs)
Labour Composite
4
5
180.48
215.17

Pointing flush on stone


work:

Specifi
cation
6

sqm

148.44

183.13

b) cement mortar 1:3


(cement & sand)

sqm

279.93

314.62

13.

Racking & washing joints


of stone masonry (old
work)

sqm

86.27

10.1 &
10.2

14.

Racking & washing joints


of birck masonry (old
work)

sqm

43.13

-do-

15.

Priming coat of
under distemper.

sqm

15.23

16.

Distempering:

17.

18.

16.76

a) One coat over and


including
cost
of
priming coat.

sqm

41.11

57.86

b) Two coat over and


including
cost
of
priming coat.

sqm

60.91

82.00

Colour Washing (Lime):


a) One coat over and
including
cost
of
priming coat.

sqm

12.78

16.40

b) Two coat over and


including
cost
of
priming coat.

sqm

21.57

27.77

White washing

10.1,
10.2 &
10.9
10.1 &
10.2

10.1,
10.2 &
10.8

10.1,
10.2 &
10.7

a) One coat
b) Two coat
c) Three coat

sqm
sqm
sqm

7.99
23.44
29.37

14.11
32.76
41.82

19.

Extra cost of labour &


material for red oxide
pigment
in
cement
pointing to match with the
colour of bricks.

sqm

12.78

18.86

10.1 &
10.2

20.

Gypsum plaster 13mm


thick upto 1st floor height.

sqm

155.38

183.44

-do-

WAPDA

-do-

a) cement mortar 1:2


(cement & sand)

chalk

Remark

10 - 2

WCSR-2013 (Zone-2)

SECTION 10 SURFACE RENDERING

Sr.
Description
No.
1
2
21. Rough
grey
cement
machine spray 1:1 (grey
cement and white marble
powder) laid uniform upto
6.0mm
thickness
minimum.

Unit
3
sqm

Rate (Rs)
Labour Composite
4
5
155.38
228.81

Specifi
cation
6
10.1,
10.2 &
10.6

22.

Rough white cement


machine spray 1:1 (white
cement
and
marble
powder) laid uniform upto
6.0mm
thickness
minimum.

sqm

155.38

270.90

-do-

23.

Preparing Surface and


Painting of Water Proof
cement base coating,
each coat.

sqm

8.81

29.89

20.8

24.

Weather shield paint


three coats on new
cement plaster surface.

sqm

60.91

213.92

25.

Weather shield paint on


painted/old surface, one
coat.

sqm

24.36

72.97

WAPDA

10 - 3

Remark
7

WCSR-2013 (Zone-2)

SECTION 11 WOOD WORK

SECTION - 11

W O O D

W O R K

1.

No extra rates to be paid for sawing as the rate are inclusive of such contingencies.

2.

Rates for all finished works shall include the removal of surplus debris, unused
material and by products.

3.

The composite rates shall constitute compensation for the completed items of works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished works.

Sr.
No.
1
1.

2.

3.

4.

Description

Unit

Plain wood works sawn


wrought, planned and
fixed in position including
cost of nails and screws
etc:

Specifi
cation
6

Remark
7

11.1

a) Deodar

cum

22679.31

220756.24

b) Shisham

cum

31509.99

123626.94

Plain wood work sawn


planned & wrought for
regulation
karries
or
needles etc:

-do-

a) Deodar

cum

17339.79

212306.19

b) Shisham

cum

26341.34

115347.74

Teak
wood
wrought
framed & fixed in place
including chowkats hold
fasts,
tower
bolts,
chocks, cleats, handles,
cord with hooks & cost of
nails and screws, etc.
panelled or panelled &
glazed or full glazed:
a) 50 mm

sqm

2477.24

21370.95

b) 45 mm

sqm

2461.22

19803.67

Teak
wood
wrought
joinery
doors
and
windows with frames and
22 SWG galvanized wire
gauze 12x12 to 25x25
sqmm meshes including
brass fittings complete:
a) Framing 44mm thick
with ordinary hinges
and fixed in position.

WAPDA

Rate (Rs)
Labour Composite
4
5

sqm

1543.42

11 - 1

11.1,
11.2 ,
11.3 &
11.12

Size 1.22 m
x 2.10 m
(4' x 6.75')

11.1&
11.8

Size 1.22 m
x 2.10 m
(4' x 6.75')

10782.02

WCSR-2013 (Zone-2)

SECTION 11 WOOD WORK

Sr.
No.
1

Description

Unit

Rate (Rs)
Labour Composite
4
5
1525.03
9212.37

2
b) Ditto 40 mm thick

3
sqm

c) Chowkats 20mm with


strips and screws.

sqm

544.63

2911.74

d) Fixed with 13mm


strips on a separate
50x50 mm frame for
C.windows.

sqm

878.94

7628.22

5.

Expanded metal 13mm


to 20mm mesh 16 gauge
fixed to chowkat with
25mm
teak
wood
moulding/strips
and
screws for window.

sqm

544.63

3176.07

6.

Deodar wood wrought


joinery work in doors &
windows etc. fixed in
position
including
chowkats,
holdfasts
hinges, iron tower bolts,
chocks, cleats handles
end cords with hooks etc.
deodar,
panelled
or
panelled and glazed or
fully glazed:

7.

8.

WAPDA

a) 50 mm

sqm

1525.92

15185.70

b) 45 mm

sqm

1343.48

13138.36

c) 40 mm

sqm

1251.82

12707.62

Deodar wood framed


braced & battened doors
& windows complete with
iron fittings & fixed in
position,
including
chowkats:

Specifi
cation
6

Remark
7

11.1 &
11.9

11.1

Size 1.22 m
x 0.6 m
(4' x 2')

11.1 ,
11.2 ,
11.3 &
11.12

Size 1.22 m
x 2.10 m
(4' x 6.75')

11.1 &
11.4

a) 55mm thick with


30mm battens and
25mm planks.

sqm

1803.27

15442.74

Size 0.91 m
x 2.13 m
(3 x 7)

b) 45mm thick with


25mm battens and
20mm planks.

sqm

1400.73

12778.13

Size 0.91 m
x 1.98 m
(3 x 6.5)

Deodar
25mm
thick
battended
doors
&
windows fixed in position
complete with iron fittings
without chowkats.

sqm

1052.48

9439.05

11 - 2

11.1,
11.4 &
11.5

Size 0.91 m
x 2.13 m
(3 x 7)

WCSR-2013 (Zone-2)

SECTION 11 WOOD WORK

Sr.
Description
No.
1
2
9. Deodar 25mm battened
ledged & braced, 55mm
& 30mm fixed in position
complete with iron fittings
with chowkats.
10.

Deodar wood frame with


braces & 22 gauges G.I.
sheet facing on one side
including
holdfast,
wooden beadings, hinges
and locking arrangement
complete.

11.

Deodar wood wrought


joinery work in wire
gauze
doors
and
windows with 22 SWG
galvanized
12x12
to
25x25 sqmm meshes
including iron fittings
complete.

Unit
3
sqm

sqm

Rate (Rs)
Labour Composite
4
5
1559.44
15532.24

723.21

6560.42

Specifi
cation
6
11.1,
11.4 &
11.5

Remark
7
Size 0.91 m
x 1.98 m
(3 x 6.5)

-do-

Size 2.44 m
x 2.44 m
(8 x 8)

-do-

Size 1.22 m
x 2.10 m
(4' x 6.75')

a) Framing with ordinary


hinges 45mm thick

sqm

1304.62

8123.71

11.1 &
11.8

b) Framing with ordinary


hinges 40mm thick.

sqm

1292.76

7246.74

-do-

c) Wire gauze fixed with


13mm
strips
on
50x50mm frame.

sqm

850.47

6135.26

11.1 &
11.9

d) Wire gauze fixed to


chowkats
20mm
strips and screws.

sqm

540.48

1844.76

11.1 &
11.10

12.

Deodar wood trellis doors


& windows complete
fixed in position.

sqm

1219.19

8007.28

11.1

Size 0.76 m
x 2.13 m
(2.5' x 7')

13.

Deodar wood panelled


work 40 mm thick
including frame work
(except doors).

sqm

846.31

9804.41

-do-

Size 1.22 m
x 2.10 m
(4' x 6.75')

14.

Extra for double action


spring hinges fixed with
brass fittings including
brass finger plate and
tower plates.

Per
sqm

15.36

398.30

11.1 &
11.2

15.

Providing & fixing brass


spring hinges to wire
gauzed doors.

Each

74.16

244.32

-do-

WAPDA

11 - 3

WCSR-2013 (Zone-2)

SECTION 11 WOOD WORK

Sr.
Description
No.
1
2
16. Proving and fixing sliding
bolt to doors:

17.

Unit
3

Rate (Rs)
Labour Composite
4
5

a) 305 mm Iron

each

74.46

257.83

b) 255 mm Iron

each

74.46

227.83

c) 305 mm Brass

each

74.46

1157.61

d) 255 mm Brass

each

74.46

953.61

Extra for brass fittings to


doors
and
windows
except for hinges which
shall be of iron:

Specifi
cation
6
11.1 &
11.2

Remark
7

-do-

a) Deodar wood panelled


or panelled & glazed
or fully glazed

sqm

22.25

c) Deodar wood wire


gauzed shutters.

sqm

17.80

18.

Extra for providing and


fixing approved quality
rim lock adjustable over
the style surface.

each

213.58

752.70

-do-

19.

Providing
&
fixing
approved quality mortice
lock.

each

213.58

694.94

-do-

20.

Expanded metal 13mm


to 20mm mesh 16 gauge
fixed with 25mm deodar
wood strips and screws.

sqm

286.85

3197.10

11.1

Size 1.22 m
x 0.6 m
(4' x 2')

21.

Expanded metal 13mm


to 20mm mesh 16 gauge
fixed with 25mm cover
moulding
&
screws
including deodar wood
frame 50 x 50 mm

sqm

820.80

6814.65

-do-

Size 1.22 m
x 0.91 m
(4' x 3')

22.

Providing
and
fixing
almirah as per standard
design
of
WAPDA
residences.

sqm

1464.51

6800.05

-do-

23.

Providing
&
fixing
wardrobe
as
per
standard,
design
of
WAPDA residences.

sqm

2065.50

4419.03

-do-

24.

Making & fixing frames


for doors, windows and
C. Windows.

WAPDA

11.1 &
11.2
11 - 4

Size 1.22 m
x 2.10 m
(4' x 6.75')
WCSR-2013 (Zone-2)

SECTION 11 WOOD WORK

Sr.
No.
1

25.

26.

Rate (Rs)
Labour Composite
4
5
514.08
5612.55

Description

Unit

3
sqm

b) Deodar

sqm

288.04

4034.46

c) Shisham

sqm

423.01

2240.96

a) Teak

Making & fixing deodar


planking in eave boards
etc. planned on both
sides rebated and fixed
including nails, screws,
bolts and brackets:

Specifi
cation
6

sqm

487.38

5477.97

b) 20 mm

sqm

487.38

4291.22

c) 13 mm

sqm

487.38

2934.93

Making and fixing deodar


wood shelves including
brackets:

-do-

a) 50 mm

sqm

487.38

10390.63

b) 40 mm

sqm

487.38

7847.59

c) 25 mm

sqm

487.38

5474.08

27.

Making and fixing cleats


for doors and windows
including hinges and
screws.

each

60.81

249.04

11.1 &
11.2

28.

Making and fixing cleats


with brass hooks for roof
ventilators.

each

60.81

78.81

-do-

29.

Hard wood railing of any


shape & design including
bends & corners fixed in
position
including
polishing complete.
m

520.68

2464.08

b) Shisham

520.68

1247.66

274.71

1373.98

31.

Sawing wood by hand:


a) Soft wood (deodar,
kail or chir).

WAPDA

11.1

a) Teak

Deodar wood dado or


picture rail 75 x 40 mm
as per approved design
including moulding &
fixing in place with
screws, nails, plugs and
painting complete.

11.1

a) 25 mm

30.

Remark

-do-

-dosqm

183.32

11 - 5

WCSR-2013 (Zone-2)

SECTION 11 WOOD WORK

Sr.
No.
1

32.

Description

Unit

2
b) Hard wood (shisham,
kikar teak or sal).

3
sqm

Sawing
machines:

wood

Rate (Rs)
Labour Composite
4
5
367.79

by

Specifi
cation
6

Remark
7

11.1

a) Soft

sqm

65.26

147.76

b) Hard

sqm

131.11

296.86

33.

Making & fixing sun


shade of deodar wood
including brackets.

sqm

582.90

6695.75

-do-

Size 1.52 m
x 0.30 m
(5' x 1')

34.

Making & fixing 25mm


thick kail or chir wood
notice board with frame.

sqm

679.90

2364.42

-do-

Size 1.88 m
x 0.91 m
(6' x 3')

35.

Making & fixing 6mm


thick ply wood in panels
including making frame
work for ceiling or
partition.

sqm

177.98

1466.93

-do-

Size 3.66 m
x 4.88 m
(12' x 16')

36.

Hard board sheets fixed


in
panels
including
making frame work for
ceiling or partition.

sqm

177.98

1253.32

-do-

Size 3.66 m
x 4.88 m
(12' x 16')

37.

Dismantling and refixing


eave boards.

81.58

38.

Making
and
fixing
wooden
stair
case
complete 600 mm to
915mm wide, from 40mm
thick plank of deodar
wood, including hand
rails.

924.33

39.

Fixing door and windows


including chowkats.

each

219.51

40.

Glazing with panes:

WAPDA

-do12299.00

-do-

11.1 &
11.2
11.12

a) Glass Panes 454 to


512gm used with
putty.

sqm

218.62

887.70

(16 oz to 18
oz)

b) Glass Panes 454 to


512 gm used with
deodar wood fillet and
putty.

sqm

218.62

1226.77

(16 oz to 18
oz)

c) Glass Panes 680 to


737gm used with
deodar wood fillet and
putty.

sqm

218.62

1361.82

(24 oz to 26
oz)

11 - 6

WCSR-2013 (Zone-2)

SECTION 11 WOOD WORK

Sr.
Description
No.
1
2
41. Glazing with plate glass
6mm thick using PVC
gasket.
42.

Proving & Fixing Flush


door leaf as per CDO
standard drawing.

43.

Providing
&
Fixing
deodar beading tapering
from 18mm to 6mm;

Unit
3
sqm

sqm

Rate (Rs)
Labour Composite
4
5
323.38
1247.85

584.74

3656.09

Specifi
cation
6
11.12

Remark
7

20.8

11.17

(i) with 60 mm width

16.36

125.35

(ii) with 76 mm width

17.85

219.63

44.

Providing
&
fixing
laminated
board
for
Cupboard upto 600mm
deep complete in all
respect.

sqm

216.25

5516.90

Size:
2.287m x
1.982m
(7 x 6)

45.

Providing
&
fixing
laminated
board
for
Wardrobe
shutter
complete in all respect.

sqm

205.27

2560.85

Size:
1.60m x
2.896m
(5 x 9)

WAPDA

11 - 7

WCSR-2013 (Zone-2)

SECTION 12 PAINTING AND VARNISHING

SECTION - 12

PAINTING AND VARNISHING


1.

No extra rates to be paid for sawing as the rate are inclusive of such contingencies.

2.

Rates for all finished works shall include the removal of surplus debris, unused
material and by products.

3.

The composite rates shall constitute compensation for the completed items of works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished works.

Sr.
Description
No.
1
2
1. Cleaning & oiling wood
work:

Unit
3

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6
12.1

a) Cleaning painted wood


work with oil & water

sqm

17.57

42.53

b) Oiling wood work with


boiled linseed oil.

sqm

17.57

52.61

2.

Brushing and scarping


blisters of old paints from
wood work.

sqm

26.70

-do-

3.

Scraping brushing and


removing oil paint from
metal surface.

sqm

127.56

-do-

4.

Painting old surfaces:

-do-

a) Painting
corrugated
surfaces,
patent
roofing, etc. with oil
paint:

12.4

i) First coat

sqm

49.84

108.35

ii) Each subsequent coat

sqm

37.38

83.35

b) Painting sashes, fan


lights,
glazed
or
gauzed
doors
&
windows:

12.2

i) First coat

sqm

30.46

63.35

ii) Each subsequent coat

sqm

24.92

52.06

c) Painting doors and


windows any type:

-do-

i) First coat

sqm

49.84

108.35

ii) Each subsequent coat

sqm

37.38

83.35

d) Painting guard bars,


gates,
iron
bars,
WAPDA

Remark

12.4

12 - 1

WCSR-2013 (Zone-2)

SECTION 12 PAINTING AND VARNISHING

Sr.
No.
1

Description
2
gratings,
railing
(including
standard
braces
etc.)
and
similar open work:

Unit
3

Rate (Rs)
Labour Composite
4
5

i) First coat

sqm

30.46

63.35

ii) Each subsequent coat

sqm

24.92

52.06

e) Painting
fillets,
framing,
skirting,
pipes, gutters and
similar linear works
not exceeding 152 mm
girth:
m

8.31

17.30

ii) Each subsequent coat

5.54

12.16

Painting
small
detached articles not
exceeding 0.10 sqm of
painted surface:
i) First coat

ii) Each subsequent coat

no.

9.69

19.97

no.

8.11

14.73
-do-

i) First coat

no.

18.79

38.24

ii) Each subsequent coat

no.

10.88

22.49

Painting new surfaces:

12.1
12.3

a) Preparing surface and


painting
corrugated
surface,
patent
roofing etc:

12.4

i) Priming coat
ii) Each subsequent coat

sqm

50.43

134.05

sqm

26.70

98.29

b) Preparing surface and


painting sashes, fans,
lights,
glazed
or
gauzed
doors
&
windows etc. any type
(including edges):
i) Priming coat
WAPDA

12.2
12.4

g) Painting
small
detached
articles
exceeding 0.10 sqm
and not exceeding
0.30 sqm of painted
surface

5.

Remark

12.4

i) First coat

f)

Specifi
cation
6

12.3

sqm

32.04
12 - 2

84.28
WCSR-2013 (Zone-2)

SECTION 12 PAINTING AND VARNISHING

Sr.
No.
1

Description

Unit

2
ii) Each subsequent coat

3
sqm

Rate (Rs)
Labour Composite
4
5
18.00
61.35

c) Preparing surface and


painting of doors and
window
any
type
(including edges):
i) Priming coat
ii) Each subsequent coat

sqm

50.43

134.05

sqm

26.70

98.29

12.4

i) Priming coat

sqm

32.04

79.66

ii) Each subsequent coat

sqm

18.00

56.73

e) Preparing surface and


painting
fillets,
framing, skirting, pipes
gutters & similar linear
works not exceeding
152mm girth:

-do-

i) Priming coat

8.31

20.44

ii) Each subsequent coat

4.15

13.67

f) Painting
small
detached articles not
exceeding 0.10 sqm
of painted surface:

12.2
12.4

i) First coat

no.

11.07

26.00

ii) Each subsequent coat

no.

4.94

17.26

g) Painting
small
detached
articles
exceeding 0.10 sqm
and not exceeding
0.30 sqm of painted
surface

WAPDA

Remark

12.3

d) Preparing surface and


painting of guard bars,
gates of iron bars,
gratings,
railings,
(including standards,
braces,
etc.)
and
similar open works:

i) First coat

Specifi
cation
6

-do-

no.

20.17

49.27

ii) Each subsequent coat

no.

9.29

31.08

h) Extra for knotting and


stepping to priming
coat on new surface
of wood.

Sqm

4.75

21.05

12 - 3

12.3

WCSR-2013 (Zone-2)

SECTION 12 PAINTING AND VARNISHING

Sr.
Description
No.
1
2
6. Providing,
preparing
surface
&
applying
3 coats of approved type
of plastic emulsion paint
to plastered surface as
per
manufacturer's
specifications.
7.

8.

9.

sqm

37.38

54.56

ii) Second coat

sqm

29.47

43.09

French
complete on;

polishing
sqm

418.22

515.17

ii) old work

sqm

221.39

272.13

Varnishing wood work


including cleaning and
preparing surface:
sqm

30.46

112.52

ii) Second coat

sqm

15.23

77.84

ii) Third coat

sqm

15.23

66.16

sqm

32.04

107.27

14.

WAPDA

sqm

28.76

55.30

ii) Second coat

sqm

17.57

39.86

painting

12.9

i) One coat work

sqm

28.48

49.01

ii) Two coat work

sqm

42.72

72.08

Creosote painting applied


hot:

-do-

i) One coat work

sqm

28.48

49.01

ii) Two coat work

sqm

42.72

72.08

45.68

53.53

Painting 600 mm with


gauge reading to 10th of
300 mm.

12.8

-do-

i) First coat

Solignum
applied hot:

12.5

i) First coat

Coaltar painting laid hot:

Remark

12.7

i) new work

11.

Specifi
cation
6
12.11

12.4 &
12.6

i) First coat

Bitumen
coatings
to
plastered
or
cement
concrete surface using
0.60 kg / sqm.

13.

3
sqm

Rate (Rs)
Labour Composite
4
5
149.51
339.54

Applying Khanki mixture


hot to barrage gates:

10

12.

Unit

12 - 4

12.4

WCSR-2013 (Zone-2)

SECTION 12 PAINTING AND VARNISHING

Sr.
Description
No.
1
2
15. Painting sounding rods &
other gauges, reading to
10th of 300 mm.
16.

Painting levelling staves

17.

Unit
3
m

Rate (Rs)
Labour Composite
4
5
22.15
23.72

Specifi
cation
6
12.4

713.52

748.03

12.9

Writing letters or figures


per letter per 25mm
height.

per no.

13.84

15.70

12.1 &
12.11

18.

Painting distance marks


for white ground and
black lettering on both
faces.

each
no.

69.22

140.23

-do-

19.

Painting (2 coats) and


lettering both sides of
intermediate stone.

each
no.

42.91

63.46

-do-

20.

Painting (2 coats) and


lettering both sides of
K.M. stone

each
no.

346.08

511.46

-do-

21.

Painting (2 coats) and


lettering of sign posts.

each
no.

456.83

622.21

-do-

22.

Painting
letters
with
shade (25 mm height)

per
letter

22.15

23.48

-do-

23.

Burning off or rubbing


down with pumice stone
old paint from wood work.

sqm

85.64

128.09

-do-

24.

Removing with caustic


soda, old paint from
wood work.

sqm

32.04

38.52

-do-

25.

Removing
paint
varnish from walls.

sqm

64.07

26.

Scarping from hydraulic


gates:

or

-do-do-

i) Khanki paint

sqm

7.71

27.40

ii) Aluminium paint

sqm

16.02

35.70

27.

Scraping rust from old


rails or girders.

sqm

95.52

106.37

-do-

28.

Chiselling old paint from


brick work.

sqm

95.52

104.22

-do-

29.

Cleaning glasses with


chalk and spirit, etc.

sqm

64.07

66.26

-do-

30.

Cleaning & oiling rafter or


rolled steel beams.

sqm

32.04

50.56

-do-

WAPDA

Remark

12 - 5

WCSR-2013 (Zone-2)

SECTION 12 PAINTING AND VARNISHING

WAPDA

12 - 6

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

SECTION-13

WATER SUPPLY AND SANITATION


1.

Rates for all finished works shall include the removal of surplus debris, unused
material and by products.

2.

The composite rates shall constitute compensation for the completed items of works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished works.

Sr.
No.
1

Description

Unit

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Remark
7

TUBEWELLS
1.

2.

WAPDA

Boring for tubewells in all


water bearing soils from
ground level to 30m
depth including sinking &
with-drawing of casing
pipe
with
internal
diameter.

13.1.2

a) 75 mm

361.44

394.10

b) 100 mm

481.29

519.22

c) 125 mm
d) 150 mm

m
m

997.71
1658.83

1060.47
1782.74

e) 200 mm

4369.69

4567.60

f) 250 mm

5365.74

5648.88

g) 300 mm

5365.74

5680.99

h) 375 mm

8342.22

8739.49

i) 450 mm

8342.22

8765.98

j) 550 mm

8342.22

8813.35

Boring for tubewells in all


water bearing soils from
30m depth below ground
level to 60m depth
including sinking & withdrawing of casing pipe
with internal diameter.

-do-

a) 100 mm
b) 125 mm

m
m

885.58
1845.63

944.87
1959.28

c) 150 mm

2538.48

2703.99

d) 200 mm

5525.58

5725.70

e) 250 mm

6364.27

6633.87

f) 300 mm

6783.62

7076.69

g) 375 mm

9692.16

10025.72

h) 450 mm

9692.16

10071.80

i) 550 mm

9692.16

10106.42

13 - 1

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
3.

4.

5.

WAPDA

Description

Unit

2
Boring for tubewells in all
water bearing soils from
60m depth below ground
level to 90m depth
including sinking & withdrawing of casing pipe
with internal diameter.

Rate (Rs)
Labour Composite
4
5

a) 100 mm

1181.39

1251.31

b) 125 mm

2572.65

2715.30

c) 150 mm
d) 200 mm

m
m

3921.81
6652.90

4125.61
6904.06

e) 250 mm

8172.93

8509.41

f) 300 mm

8172.93

8541.52

g) 375 mm

10352.5
1

10803.13

h) 450 mm

10352.5
1

10829.62

i) 550 mm

10352.5
1

10876.99

Boring for tubewells in all


water bearing soils from
90m depth below ground
level to 120m depth
including sinking & withdrawing of casing pipe
with internal diameter.

Specifica
tion
6
13.1.2

Remark
7

-do-

a) 200 mm

7779.42

8057.29

b) 250 mm
c) 300 mm

m
m

9561.44
9561.44

9924.55
9956.67

d) 375 mm

11702.46

12179.71

e) 450 mm

11700.06

12203.80

f) 550 mm

11700.06

12251.17

Boring for tubewells in all


water bearing soils from
120m
depth
below
ground level to 150m
depth including sinking &
with-drawing of casing
pipe
with
internal
diameter.

-do-

a) 200 mm
b) 250 mm

m
m

8905.93
10949.95

9210.44
11339.70

c) 300 mm

10949.95

11371.81

d) 375 mm

13324.49

13828.37

e) 450 mm

13322.09

13852.46

13 - 2

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

Rate (Rs)
Labour Composite
4
5

Specifica
tion
6

Description

Unit

6.

Providing
strong
substantially built wooden
locked box size 600 x
600 x 230mm with
compartments
for
preserving 1.0kg samples
of strata obtained from
the bore hole and taking
preserving in box 1.0kg
samples
of
strata
obtained from the bore
hole.

Job

1414.72

8518.85

13.1.2.3
13.1.2.4

7.

Furnishing samples of
water from bore hole
including
necessary
pumping
or
boiling,
providing
sampling
bottles and filling water
samples in to it.

Job

92.70

121.50

13.1.2.4

8.

Providing & installation


brass strainer of following
diameter into tubewell
bore
including
M.S.
reducer, sockets & bail
plugs.

9.

WAPDA

Remark
7

13.1.3

a) 40 mm

62.91

973.74

b) 50 mm

108.64

1245.97

c) 75 mm

108.64

1545.13

d) 100 mm

134.98

2566.28

e) 125 mm

200.48

4085.83

f) 150 mm
g) 175 mm

m
m

287.54
287.54

4030.91
4439.17

h) 200 mm

442.73

5211.00

i) 225 mm

442.73

5899.16

j) 250 mm
k) 300 mm

m
m

552.16
662.95

6637.98
9143.50

l) 375 mm

793.95

13985.86

Providing and installing


PVC class 'B' strainer of
following
diameter
including
bail
plug,
sockets & solution.

-do-

a) 75 mm

103.55

480.75

b) 100 mm

112.96

665.42

c) 125 mm

112.96

896.60

d) 150 mm

128.65

1236.49

e) 200 mm

167.90

1869.04

13 - 3

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

10.

11.

12.

WAPDA

Description

Unit

2
f) 250 mm
g) 300 mm

3
m
m

h) 350 mm

Rate (Rs)
Labour Composite
4
5
167.90
3495.10
207.41
4799.81
207.41

Specifica
tion
6

Remark
7

6063.65

Providing and installing


PVC class 'D' strainer of
following
diameter
including
bail
plug,
sockets & solution.

13.1.3

a) 32 mm

58.47

194.14

b) 40 mm

58.47

238.82

c) 50 mm
d) 63 mm

m
m

63.15
63.15

336.97
491.03

e) 75 mm

103.55

685.47

f) 100 mm

112.96

1084.68

g) 125 mm
h) 150 mm

m
m

112.96
128.65

1561.99
2232.60

Providing & installing


fibre glass strainer of
following diameter with
bail
plug
including
sockets & solution etc
complete.

-do-

a) 150 mm

128.65

6515.60

b) 200 mm
c) 250 mm

m
m

167.90
167.90

8272.22
10486.37

d) 300 mm

207.41

13002.38

e) 450 mm

207.41

19434.08

Providing & installing mild


steel blind pipe having
following diameter (mm)
& thickness (mm) with
sockets into tubewell
bore
hole
including
jointing/welding
with
strainer.

-do-

a) 50, 3

108.64

868.83

b) 75, 3

108.64

1733.20

c) 100, 3
d) 125, 5

m
m

134.98
200.48

2505.52
3566.87

e) 150, 5

287.54

4829.78

f) 175, 5

287.54

6382.43

g) 200, 5
h) 225, 5

m
m

442.73
442.73

8090.27
9819.32

13 - 4

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

13.

14.

15.

WAPDA

Description

Unit

2
i) 250, 6
j) 300, 6

3
m
m

k) 375, 6

Rate (Rs)
Labour Composite
4
5
552.16
11657.80
662.95
14816.44
793.95

Specifica
tion
6

Remark
7

20863.28

Providing & installing


PVC class 'B' blind pipe
of following diameter into
tubewell
bore
hole
including
sockets
&
solution.

13.1.3

a) 75 mm

103.55

529.11

b) 100 mm

112.96

756.92

c) 125 mm
d) 150 mm

m
m

112.96
128.65

990.63
1371.28

e) 200 mm

167.90

2080.45

f) 250 mm

167.90

3906.85

g) 300 mm
h) 350 mm

m
m

207.41
207.41

5774.11
7600.51

Providing and installing


PVC class D blind pipe
of following diameter into
tubewell
bore
hole
including
sockets
&
solution.

-do-

a) 32 mm

58.47

210.28

b) 40 mm
c) 50 mm

m
m

58.47
63.15

270.74
343.01

d) 63 mm

63.15

502.37

e) 75 mm

103.55

702.11

f) 100 mm
g) 125 mm

m
m

112.96
112.96

1112.72
1603.63

h) 150 mm

128.65

2292.08

Providing & installing


fibre glass blind pipe of
following diameter into
tubewell bore with socket
& solution.

-do-

a) 150 mm

128.65

5330.92

b) 200 mm

167.90

6737.68

c) 250 mm
d) 300 mm

m
m

193.19
207.41

8575.87
10864.03

e) 450 mm

207.41

15599.82

13 - 5

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
16.

17.

18.

Description

Unit

2
Shrouding
&
filling
around strainer/blind pipe
graded bajri (3mm to
10mm)
into
space
between the bore wall
and strainer/blind pipe
with internal diameter:

Rate (Rs)
Labour Composite
4
5

a) 75 mm

392.99

486.87

b) 100 mm

589.48

703.77

c) 125 mm

589.48

722.14

d) 150 mm

785.98

928.84

e) 175 mm

785.98

947.20

f) 200 mm

785.98

965.57

g) 225 mm

982.47

1182.47

h) 250 mm
i) 300 mm

m
m

982.47
982.47

1190.64
1229.41

j) 375 mm

1178.96

1529.99

Providing & placing of


cement sand grout (1:1)
around blind pipe & bore
hole wall with internal
diameter:

Specifica
tion
6
13.1.4

Remark
7

13.1.5

a) 75 mm
b) 100 mm

m
m

39.14
59.11

506.87
621.24

c) 125 mm

59.11

715.11

d) 150 mm
e) 175 mm

m
m

78.28
78.28

780.96
874.24

f) 200 mm

78.28

968.65

g) 225 mm

118.22

1102.46

h) 250 mm
i) 300 mm

m
m

118.22
157.36

1149.13
1374.90

j) 375 mm

157.36

1889.89

Testing & developing of


tubewell of size 150 mm
(6) size and above.

13.1.6

a) Development by Air lift


Tool Method
i) Discharge upto
0.0425 cumec
(1.50 cusecs).

each

14514.36

84214.55

ii) Discharge above


0.0425 cumec (1.50
cusecs).

each

24190.60

163590.97

b) Development &
Testing by pumping
WAPDA

13 - 6

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

19.

20.

21.

22.

WAPDA

Description

Unit

2
(Raw Hiding) Method
i) Discharge upto
0.0425 cumec (1.50
cusecs).
ii) Discharge above
0.0425 cumec
(1.50 cusecs).

Rate (Rs)
Labour Composite
4
5

each

18848.93

71997.30

each

18848.93

85237.30

PIPE LINES
Providing, lowering &
laying
into
trenches,
jointing & testing A.C.
class B pipe line with
internal diameter.

Specifica
tion
6

Remark
7

13.2.2.15
13.2.4
to
13.2.9

a) 75 mm

97.28

491.64

b) 100 mm

111.18

705.03

c) 150 mm

161.40

1302.72

d) 200 mm

224.55

2050.19

e) 250 mm

285.29

3231.38

f) 300 mm

373.24

4316.82

g) 400 mm

373.24

6868.54

Providing, laying into


trenches,
jointing
&
testing PVC class 'B' pipe
line with specials for
internal :

-do-

a) 75 mm

65.52

617.80

b) 100 mm

97.28

933.49

c) 150 mm

130.44

1744.23

d) 200 mm

162.80

2646.66

e) 250 mm
f) 300 mm

m
m

195.15
228.31

5053.34
7462.17

g) 375 mm

260.08

9868.26

Providing, lowering &


laying
into
trenches
jointing and testing PVC
class 'D' pipe line with
specials for internal :

-do-

a) 50 mm

49.04

412.18

b) 75 mm

65.52

842.70

c) 100 mm
d) 150 mm

m
m

97.28
130.44

1396.03
2941.27

Lowering,
laying
in
trenches and jointing
RCC plain or glazed

13.3.2.1.3
13.3.3
to
13 - 7

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

23.

Description

Unit

2
earthen
ware
pipes,
specials in 1:1:5 cement,
sand mortar and finishing
the dowel to angle of 45
with 1:1 cement sand
mortar including cost of
yarn, cutting & chipping
where
required
with
internal diameter:

a) 100 mm
b) 150 mm
c) 175 mm
d) 200 mm
e) 225 mm
f) 250 mm
g) 300 mm
h) 375 mm
i) 450 mm
j) 525 mm
k) 600 mm
l) 675 mm
m)750 mm

m
m
m
m
m
m
m
m
m
m
m
m
m

WAPDA

59.74
59.74
59.74
89.45
89.45
106.38
130.70
158.64
193.09
220.11
249.18
294.05
337.99

Specifica
tion
6
13.3.5
13.3.9

Remark
7

71.56
72.14
75.96
108.06
109.17
128.27
156.11
186.23
223.13
255.02
286.85
336.35
385.16

Providing, lowering &


laying into trenches and
jointing cement concrete
reinforced pipeline to
correct
alignment
&
grade including cutting of
pipes where necessary
cost of jointing material &
testing
with
internal
diameter:.
a) 100 mm
b) 150 mm
c) 175 mm
d) 200 mm
e) 225 mm
f) 250 mm
g) 300 mm
h) 375 mm
i) 450 mm
j) 525 mm
k) 600 mm
l) 675 mm
m)750 mm

24.

Rate (Rs)
Labour Composite
4
5

13.3.2.1.3
13.3.3.
to
13.3.6
13.3.9

m
m
m
m
m
m
m
m
m
m
m
m
m

59.74
59.74
59.74
89.45
89.45
106.38
130.70
158.64
193.09
220.11
249.18
294.05
337.99

Lowering & laying cast


iron pipes & specials into
trenches of any depth,
to required alignment &

246.93
529.46
759.96
834.00
848.26
995.70
1177.55
1489.60
1783.90
2091.27
2398.59
3082.18
3737.46
13.3.2.1.1
13.3.3.
to
13.3.6

13 - 8

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

Description
Gradients
diameter:

2
with

internal

a) 50 mm
b) 63 mm
c) 75 mm
d) 100 mm
e) 125 mm
f) 150 mm
g) 175 mm
h) 200 mm
i) 225 mm
j) 250 mm
k) 300 mm
l) 375 mm
25.

26.

m
m
m
m
m
m
m
m
m
m
m
m

Rate (Rs)
Labour Composite
4
5

a)

75 mm

b)
c)
d)
e)

100 mm
125 mm
150 mm
175 mm

Remark
7

13.2.4.6
13.3.6.5

Per
joint
-do-do-do-do-

278.41

780.76

318.35
358.28
417.61
457.55

942.30
1163.72

1301.09

1537.65

Making flanged joints for


cast iron pipes, valves
and specials including
cost of all bolts, nuts &
rubber packing etc with
internal diameter:

b) 63 mm
c) 75 mm
d) 100 mm
e) 125 mm
f) 150 mm
g) 175 mm
h) 200 mm
i) 225 mm
j) 250 mm
k) 300 mm
l) 375 mm

Specifica
tion
6
13.3.9

25.97
33.91
41.85
46.60
59.13
63.87
75.01
82.95
100.98
110.47
133.24
175.59

Jointing cast iron socket


& spigot pipes, valves &
specials with run lead
duly caulked including
testing (inclusion of cost
of yarn, lead fuel & tools
etc)
with
internal
diameter:

a) 50 mm

WAPDA

Unit

-do-

Per
joint
-do-do-do-do-do-do-do-do-do-do-do-

174.00

397.25

174.00
174.00
217.16
260.31
303.46
348.01
391.16
434.32
522.01
608.32
696.02

469.25
472.44
519.66
634.81
752.86
872.89
992.68
1111.31
1271.01
1508.86
1828.21

13 - 9

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
27.

Description

Unit

2
Providing and fixing G.I.
flanges including bolts,
nuts, gasket etc and
cutting threads to pipes &
specials with internal
diameter:.

a) 50 mm

Per
joint
-do-do-do-do-do-do-do-do-do-do-do-

b) 63 mm
c) 75 mm
d) 100 mm
e) 125 mm
f) 150 mm
g) 175 mm
h) 200 mm
i) 225 mm
j) 250 mm
k) 300 mm
l) 375 mm
28.

29.

WAPDA

217.16

1280.41

217.16
217.16
260.31
348.01
389.77
434.32
477.47
563.77
651.47
737.78
825.48

1544.41
1775.60
2062.81
3026.51
3479.17
3935.19
4390.99
4888.77
5384.47
5958.32
6613.67

Providing & fixing C.I.


surface boxes for sluice
valves, fire hydrants, air
valves and metre boxes
etc., but excluding the
cost
of
masonry
chamber:

Specifica
tion
6
13.2.4.6.3

Remark
7

13.2.2.5
13.2.4.9

a)

Sluice valves (230


x 230 mm)

each

119.81

1418.06

b)

Air valves, metre


box & fire hydrants
(230 x 150 mm)

each

99.84

747.92

c)

Air valves, metre


box & fire hydrants
(100 x 100 mm)

each

79.88

388.63

Providing & fixing ferrules


including
drilling
&
tapping pipelines and
screwing in ferrules &
connections with internal
diameter:
a) 13 mm
b) 20 mm
c) 25 mm

30.

Rate (Rs)
Labour Composite
4
5

13.2.2.6
132.4.10

each
each
each

119.81
175.73
263.59

Cutting cast iron pipes &


specials and chipping off
or filling surface to a
uniform
finish
with
internal diameter:

282.26
385.43
547.54
13.2.4.2

13 - 10

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

Description

Unit

2
a) 50 mm

3
each
cut
-do-do-do-do-do-do-do-do-do-do-

b) 63 mm
c) 75 mm
d) 100 mm
e) 125 mm
f) 150 mm
g) 175 mm
h) 200 mm
i) 225 mm
j) 250 mm
k) 300 mm
31.

b) 63 mm
c) 75 mm
d) 100 mm
e) 125 mm
f) 150 mm
g) 175 mm
h) 200 mm
i) 225 mm
j) 250 mm
k) 300 mm
32.

Construction of sluice
valve or fire hydrant
chamber
610x610mm
minimum size, 230mm
thick brick work 1:5
cement sand mortar,
114mm
thick
1:4:8
cement
concrete
in
foundation 50mm thick
1:2:4 cement concrete in
bed, 75mm 1:2:4 RCC
slab on top and 13mm
thick 1:3 cement sand
plaster inside.

33.

Providing
&
fixing
socketed
or
flanged
sluice valve complete in
all respects with internal

Specifica
tion
6

Remark
7

247.61
335.48
399.38
407.37
439.32
455.29
495.23
559.13
654.98
766.81

Providing
&
fixing
temporary
wooden
tapered plugs of hard
wood to ends of pipe
lines
with
internal
diameter:
a) 50 mm

WAPDA

Rate (Rs)
Labour Composite
4
5
231.64

13.2.4.1

each
plug
-do-do-do-do-do-do-do-do-do-do-

11.98

27.43

11.98
17.57
29.55
39.94
43.93
53.52
57.51
60.71
67.10
90.26

14.95
54.21
85.99
122.12
155.82
200.06
266.43
346.86
413.65
671.48

per
job

5219.99

11405.73

13.2.4.8

13.2.2.2
13.2.4.8

13 - 11

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

34.

Description

Unit

a) 50 mm
b) 63 mm
c) 75 mm
d) 100 mm
e) 125 mm
f) 150 mm
g) 175 mm
h) 200 mm
i) 225 mm
j) 250 mm
k) 300 mm
l) 375 mm

each
each
each
each
each
each
each
each
each
each
each
each

diameter:

WAPDA

Remark
7

13.2.2.3
13.2.4.9

each
each

303.53
303.53

2004.61
2410.56
13.2.2.1.3
13.2.4.6
to
13.2.9

m
m
m
m
m
m
m
m
m
m
m

65.52
78.30
91.87
110.86
123.64
133.73
156.00
175.58
221.51
286.44
312.79

Providing, laying, jointing


& testing heavy water or
steam quality G.I. or W.I.
pipes & specials inside
buildings & trenches with
internal diameter:
a) 13 mm
b) 20 mm
c) 25 mm

Specifica
tion
6

2224.81
2250.56
20733.46
31803.48
44453.79
7246.70
10302.98
13357.46
14445.96
15620.36
25909.81
36177.96

Laying, jointing fixing &


testing G.I. or W.I. pipes
lines with all specials
inside
buildings
&
trenches with internal
diameter:
a) 13 mm
b) 20 mm
c) 25 mm
d) 32 mm
e) 40 mm
f) 50 mm
g) 63 mm
h) 75 mm
i) 100 mm
j) 125 mm
k) 150 mm

36.

348.01
348.01
348.01
434.32
520.62
606.93
696.02
782.32
868.63
1044.03
1216.64
1216.64

Providing & fixing fire


hydrants complete in all
respects with internal
diameter:
a) 50 mm
b) 65 mm

35.

Rate (Rs)
Labour Composite
4
5

-do-

m
m
m

65.52
78.30
91.87
13 - 12

232.13
308.39
416.41
WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

37.

Description

Unit

2
d) 32 mm
e) 40 mm
f) 50 mm
g) 63 mm
h) 75 mm
i) 100 mm
j) 125 mm
k) 150 mm

3
m
m
m
m
m
m
m
m

Providing & fixing flanges


to G.I. or W.I. pipes
including all bolt, nuts,
washers & gaskets etc.
for internal diameter:
a) 13 mm
b) 20 mm
c) 25 mm
d) 32 mm
e) 40 mm
f) 50 mm
g) 63 mm
h) 75 mm
i) 100 mm

38.

WAPDA

Specifica
tion
6

Remark
7

13.2.4.6

Per
joint
-do-do-do-do-do-do-do-do-

129.46

572.19

129.46
129.46
129.46
174.00
174.00
174.00
174.00
217.16

627.86
674.26
726.10
1244.44
1305.31
1497.31
1726.76
2011.71

Dismantling, disjointing,
removing & cleaning of
external surface of G.I. or
W.I. pipe line with
specials,
valves
and
fittings and removal of
holder bates and stacking
all material at site of work
for internal diameter:
a) 13 mm
b) 20 mm
c) 25 mm
d) 32 mm
e) 40 mm
f) 50 mm
g) 63 mm
h) 75 mm
i) 100 mm

39.

Rate (Rs)
Labour Composite
4
5
110.86
525.81
123.64
656.01
133.73
801.06
156.00
1060.33
175.58
1231.62
221.51
1705.06
286.44
2453.13
312.79
2954.81

13.5.13

m
m
m
m
m
m
m
m
m

32.36
55.43
78.30
110.86
133.73
156.00
179.66
201.94
225.01

Refixing,
cleaning
threads and rejointing
dismantled G.I. or W.I.
pipes, specials, valves
and fittings etc. complete

13.2.4

13 - 13

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

Description
2
in all respects
internal diameter:

Unit
with

a) 13 mm
b) 20 mm
c) 25 mm
d) 32 mm
e) 40 mm
f) 50 mm
g) 63 mm
h) 75 mm
i) 100 mm
40.

m
m
m
m
m
m
m
m
m

Rate (Rs)
Labour Composite
4
5

Specifica
tion
6

13.4.7

a) Upto 455mm thickness

each

380.69

428.71

b) Upto 915mm thickness

each

502.51

599.13

41.

Cutting
holes
upto
230mm square for pipes
in floors and roofs of
bricks or tiles with base
concrete and making
good to original condition
upto 300mm thickness.

each

190.34

204.41

-do-

42.

Cutting
holes
upto
230mm square for pipes
in floors and roofs of
cement,
reinforced
cement
concrete
or
reinforced brick work &
making good to original
condition
150mm
thickness.

each

284.75

327.15

-do-

43.

Cutting slots upto 230mm


wide in cement concrete,
conglomerate floors &
making good to original
condition upto 50mm
thickness of topping.

499.46

684.67

-do-

44.

Providing & fixing C.I. or


W.I. pipe sleeve pieces
having following diameter
in walls, floors & roofs.

WAPDA

45.94
78.30
101.37
133.73
149.61
166.08
189.15
211.43
235.09

Cutting holes 230mm


square through stone,
brick or concrete block
masonry in cement walls
for pipes and making
good to original condition:

a) 13 mm
b) 20 mm

Remark

13.5.8

each
each

55.77
55.77
13 - 14

91.85
97.51
WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

45.

46.

WAPDA

Rate (Rs)
Labour Composite
4
5
74.36
135.91
74.36
141.57

Description

Unit

2
c) 25 mm
d) 32 mm

3
each
each

e) 40 mm

each

92.95

176.44

f) 50 mm

each

92.95

465.54

g) 63 mm
h) 75 mm

each
each

111.54
130.13

498.95
532.36

i) 100 mm

each

139.42

651.09

j) 125 mm
k) 150 mm

each
each

148.72
167.30

860.59
1079.38

Providing
&
fixing
galvanized malleable iron
holder bats or hold fasts
to pipe lines fixed on
walls
and
ceilings
including cutting walls or
ceiling & making good to
original condition with
internal diameter;

Specifica
tion
6

Remark
7

13.5.7

a) 13 mm

each

15.98

21.19

b) 20 mm

each

30.62

37.03

c) 25 mm
d) 32 mm

each
each

36.19
44.55

45.80
57.07

e) 40 mm

each

55.68

75.17

f) 50 mm

each

61.25

93.26

g) 63 mm
h) 75 mm

each
each

66.82
72.39

105.79
116.93

i) 100 mm

each

86.31

119.91

Providing & fixing hard


brass or gun metal peet
valves heavy pattern with
hand wheel on G.I. or
W.I. pipe lines laid in the
ground or inside buildings
for diameter:

13.5.4

a) 13 mm

each

334.09

445.44

b) 20 mm

each

403.69

563.75

c) 25 mm

each

473.29

709.91

d) 32 mm
e) 40 mm

each
each

542.89
598.58

893.18
1099.64

f) 50 mm

each

1224.99

1930.20

g) 63 mm

each

1461.64

2742.14

h) 75 mm

each

1851.41

3521.63

i) 100 mm

each

2046.29

4927.43

13 - 15

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
47.

48.

49.

50.

Description
2
Providing
and
75mm dia G.I.
(China)

Unit
fixing
Union

3
each

Rate (Rs)
Labour Composite
4
5
174.00
1407.60

Providing and fixing stop


chocks of gun metal or
hard brass, screw down
type on G.I. or W.I. pipe
lines, laid in trenches or
inside
buildings
for
diameter:

Specifica
tion
6
13.2
13.5

Remark
7

-do-

a) 13 mm

each

b) 20 mm
c) 25 mm

each
each

107.83
133.39
149.37

167.11
224.48
318.52

Providing & fixing bib tap


of gun metal or hard
brass, screw down type
on G.I. or W.I. pipe lines
having diameter;

13.5.5

a) 13 mm
b) 20 mm

each
each

107.83
133.39

226.14
234.60

c) 25 mm

each

149.37

288.16

Providing, fixing and


testing gun metal gate
valve
complete
for
diameter:

13.5.4

a) 50 mm

each

174.00

3594.00

b) 75 mm

each

348.01

9948.01

51.

Providing & fixing reflux


valve having diameter of
100 mm.

each

348.01

1308.39

13.5.4.2

52.

Providing & fixing C.I.


surface box for peet
valves or stop cocks
(100mm x 100mm).

each

99.84

341.10

13.2.2.5

53.

Construction
of
peet
valves or stop cock
masonry chamber of size
230mm x 230mm.

each

539.57

1514.52

13.2.4.8

SURFACE DRAINS
54.

WAPDA

Making
house
outlet
connection
including
cutting
and
forming
parnalas and making
khuras:

13.7.1

13 - 16

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

55.

a) 300mm x 300mm

each

Description

Unit

2
b) 300mm x 150mm

3
each

c) 230mm x 150mm

each

291.93
416.16
Rate (Rs)
Labour Composite
4
5
273.40
344.48
277.79

Tega formed first class


bricks on end laid to
lines, grades, slopes &
shape with cement sand
mortar 1:5 thick:
44.77

131.78

b) 115 mm

66.86

191.19

56.

First class bricks laid flat


in reimbursement in &
over 1:6 cement sand
mortar on sides of drains
and in other works where
required, over cement
concrete
or
other
foundation. All joints to be
left completely filled &
struck flush.

sqm

217.26

616.20

57.

First class bricks laid on


edge in reimbursement in
& over following cement
sand mortar on sides of
drains & in other works
where required, over
cement concrete or other
foundation. All joints to
be left completely filled
and struck flush:

WAPDA

13.7.1

59.

Remark

337.24

a) 75 mm

58.

Specifica
tion
6

-do-

-do-

a) 1:5

sqm

309.24

922.47

b) 1:6

sqm

309.24

905.03

First class flat bricks


herring bond pitching laid
to the lines grades
shapes & slopes in
Cement sand mortar:

-do-

a) 1:5

sqm

202.76

611.69

b) 1:6

sqm

202.76

758.73

First class bricks on edge


herring bond pitching laid
to the lines, grades,
shapes & slopes in
Cement sand mortar:

13.7.2

a) 1:5

sqm

259.98

873.21

b) 1:6

sqm

259.98

855.77

13 - 17

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
60.

Description

Unit

Rate (Rs)
Labour Composite
4
5

Constructing
Punjab
Standard
drains
consisting
of
drain
cunette
of
cement
concrete 1:2:5 over
cement concrete 1:6:18
in foundation complete
laying to lines grades,
slopes and shapes:

Specifica
tion
6

Remark
7

13.7.1

a) Type - I

226.40

789.79

b) Type - II

324.11

1100.93

c) Type - III
d) Type - IV

m
m

377.80
441.04

1178.45
1434.00

e) Type - V

561.58

1774.03

f) Type - VI

591.38

1822.78

g) Type - VII
h) Type - VIII

m
m

666.83
835.73

2095.42
2649.73

i) Type - IX

1119.64

3554.65

j) Type - X

1218.50

3856.08

k) Type - XI
l) Type - XII

m
m

1286.75
1412.96

4129.61
4470.17

PROVIDING & FIXING


SANITARY, GAS &
LABORATORY
INSTALLATIONS
61.

White glazed earthen


ware
water
closet
European type domestic
of best quality.

each

370.80

2542.88

13.4.6.4

62.

White glazed earthen


ware
water
closet
squatting type domestic
orrisa pattern of best
quality.

each

370.80

1646.66

-do-

63.

White glazed earthen


ware
water
closet
squatting type domestic
Indian pattern of best
quality.

each

370.80

1510.80

-do-

64.

White glazed earthen


ware wash hand basin
domestic of supreme
quality:

WAPDA

13.4.6.1

a) 65 cm
b) 55 /56 cm

each
each

370.80
370.80

1267.17
1093.68

c) 45 cm

each

370.80

925.97

13 - 18

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1

Rate (Rs)
Labour Composite
4
5

Specifica
tion
6

Description

Unit

65.

White glazed earthen


ware pedestal for wash
basin
domestic
of
supreme quality.

each

370.80

1205.91

13.4.6.1

66.

White glazed earthen


ware sink domestic best
quality (45 cm x 60 cm).

each

370.80

3154.50

13.4.6.3

67.

Stainless Steel sink:


a) 50 cm x 100 cm
b) 50 cm x 125 cm

68.

White glazed earthen


ware urinal local best
quality flat back/corner
type.

69.

Providing & fixing bath


tub of best quality (fiber
glass):
a) Plain
b) With Arm Rest

70.

71.

low
level
flushing
cistern13.5 litres capacity
best quality:
a) White glazed
earthen ware
b) Plastic

3989.61
4407.17

each

556.20

1546.20

each
each

1038.24
1038.24

6048.90
9389.35
13.4.6.4

each

370.80

1723.18

each

370.80

1723.18
-do1901.84

b) 4.5 litres capacity

each

370.80

1674.50

each

370.80

5978.25

each

74.16

1445.45

b) Chromium plated

each

74.16

2125.04

c) Plastic

each

74.16

765.84

c) Plastic

13.4.6.5

13.4.6.10

a) Glazed earthenware

Toilet paper holders:


a) Glazed earthenware
b) Chromium plated

13.4.6.7

13.4.6.9

370.80

Soap dishes:

WAPDA

370.80
370.80

each

73.

74.

each
each

a) 13.5 litres capacity

White glazed earthen


ware bidet with all
hardware
fittings
complete of supreme
quality.

-do-

Cast iron high level


cistern of best quality

72.

Remark

13.4.6.6
each
each

74.16
74.16

953.92
1809.52

each

74.16

526.12

13 - 19

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
75.

76.

77.

78.

79.

Description

Unit

2
Tooth brush holder with
tooth paste dish:

a) Glazed earthen ware

each

74.16

1591.04

b) Chromium plated

each

74.16

2343.44

c) Plastic

each

74.16

462.44

Tumblers holders

81.

82.

83.
84.

WAPDA

Specifica
tion
6
13.4.6.10

Remark
7

-do-

a) Glazed earthenware

each

74.16

350.69

b) Chromium plated
c) Plastic

each
each

74.16
74.16

267.18
141.92

Looking glass 550mm x


400mm size 1st quality
(without frame):

13.4.6.2

a) Pak made

each

74.16

693.07

b) Belgium / Japan made

each

74.16

1143.07

Chromium plated towel


rail /ring:

13.4.6.10

Rail 600mm x 20mm

each

74.16

2893.57

Rail 500mm x 13mm


Ring 150mm

each
each

74.16
74.16

2326.64
1774.64

Glass shelves 600mm x


125mm size with C.P.
brackets:
a) With C.P. railing
b) Without railing

80.

Rate (Rs)
Labour Composite
4
5

13.4.6.12

each
each

74.16
74.16

325.05
255.45

C.P. Pillar cocks:


a) 13 mm

each

53.40

494.15

b) 20 mm

each

53.40

656.53

C.P. stop cocks:

13.4.6.3
13.5.5

13.5.5.

a) 13 mm

each

53.40

470.95

b) 20 mm

each

53.40

554.46

C.P. bib tap:

-do-

a) 13 mm

each

53.40

475.59

b) 20 mm

each

53.40

624.05

Brass bib tap 13mm

each

53.40

192.58

C.P. waste coupling:

13.5.5.
13.4.6.3

a) 32 mm

each

53.40

290.01

b) 40 mm

each

53.40

498.79

13 - 20

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
85.

Description
2
Rubber plug with Chain:

Unit
3

Rate (Rs)
Labour Composite
4
5

Specifica
tion
6
13.4.6.1

a) 32 mm

each

26.70

68.45

b) 40 mm

each

26.70

110.21

86.

PVC flushing pipe:


32mm

each

53.40

95.15

13.4.6.4

87.

PVC flushing bend:


32mm

each

53.40

76.59

-do-

88.

Waste pipe for wash


hand basin 32mm :

89.

a) PVC

each

53.40

95.15

b) Nickle
c) C.P. brass

each
each

53.40
53.40

401.36
691.33

Waste pipe for sinks &


urinals 40mm

-doeach

53.40

150.82

b) Nickle

each

53.40

429.19

c) C.P. brass

each

53.40

758.60

90.

C.P. bottle trap with


C.P. waste pipe 32 mm

each

222.48

1196.78

91.

C.I. brackets:
a) For wash basins

each

111.24

222.59

b) For sinks

each

111.24

264.34

Connections 13 mm
a) PVC
b) BCP

93.

94.

WAPDA

-do-

a) PVC

92.

Remark

-do13.4.6.1
13.4.6.3

13.4
each
each

111.24
111.24

166.91
208.67

Brass ball valves having


diameter:

13.4.6.4

a) 13 mm

each

53.40

290.01

b) 20 mm

each

53.40

387.44

c) 25 mm

each

53.40

554.46

d) 32 mm

each

53.40

1013.77

e) 40 mm

each

53.40

1473.08

f) 75 mm

each

53.40

1974.15

C.P. tee stop cocks:

13.5.5

a) 13 mm

each

111.24

459.20

b) 20 mm

each

111.24

500.96

13 - 21

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
95.
96.

Description

Unit

2
13mm x 100mm C.P.
shower rose.

3
each

Rate (Rs)
Labour Composite
4
5
111.24
352.49

Telephonic shower:

Specifica
tion
6
13.4.6.8

each

222.48

3006.18

b) Without mixing valves.

each

53.40

821.23

97.

Chromium plated shower


13mm complete with C.P.
arm, 2 Nos. C.P. stop
cock 1 No. C.P. bib cock
& 1 No. C.P. shower.

each

370.80

3186.98

-do-

98.

Chromium plated mixing


valves.

each

1503.09

13.5.5

99.

Chromium
plated
or
oxidised gas cock 6 mm.

111.24

13.5.1.3

a) Single way

each

55.18

398.50

b) Two way

each

77.42

504.26

c) Three way

each

116.58

613.01

100.

Nipple or bush 6mm to


10mm diameter.

each

39.16

66.99

-do-

101.

Copper pipe 6 mm to
10 mm diameter.

17.80

203.38

-do-

102.

Chromium
plated
or
oxidized
swan
neck
cocks 13 mm diameter:

104.

each
each

55.18
111.24

542.32
1196.88

c) Three way

each

166.42

1377.33

P. Trap brass, diameter:

WAPDA

13.4.6.4
each
each

111.24
111.24

974.19
1294.31

P. Trap C.P, diameter:


a) 32 mm
b) 40 mm

105.

-do-

a) Single way
b) Two way

a) 32 mm
b) 40 mm

-do-

a) With mixing valves

103.

Remark

-doeach
each

111.24
111.24

904.60
1224.72

S. Trap brass, diameter:

-do-

a) 32 mm

each

111.24

974.19

b) 40 mm

each

111.24

1322.15

13 - 22

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
106.

Description
2
S. Trap C.P. diameter:

Rate (Rs)
Labour Composite
4
5

Unit
3

a) 32 mm

each

111.24

974.19

b) 40 mm

each

111.24

1322.15

107.

S. Trap 102 mm diameter


China-ware
(Pakistan
made)

each

185.40

282.83

108.

Floor trap 100mm x


50mm (including 50 mm
concrete chamber all
round):

Specifica
tion
6
13.4.6.4

-do-

13.4.5

a) With C.I. grating

each

143.14

444.49

b) With C.P. grating

each

143.14

458.40

109.

Gully
trap
100mm
diameter
of
cement
concrete
(including
305mm
x
305mm
masonry chamber and
C.I. grating 150mm x
150mm)

each

855.26

2104.92

-do-

110.

Gully
trap
100mm
diameter of cast iron
(including
305mm
x
305mm
masonry
chamber)

each

855.26

2651.02

-do-

111.

Seat
&
cover
for
European type water
closet (Pakistan made)
a) Bakelite
b) PVC

Remark

13.4.6.4

each
each

56.06
56.06

668.48
515.38

PROVIDING AND
FIXING SOIL PIPES &
FITTINGS
112.

113.

WAPDA

C.I. soil pipes with lead


chaulked
joints
for
diameter:

13.3.2.1
13.3.6.5

a) 50 mm

87.81

1400.00

b) 100 mm

112.13

1952.38

C.I. soil specials with


lead/wood
chaulked
joints for diameter:

-do-

a) 50 mm

Special

148.32

423.07

b) 100 mm

Special

222.48

659.15

13 - 23

WCSR-2013 (Zone-2)

SECTION 13 WATER SUPPLY AND SANITATION

Sr.
No.
1
114.

Description

Unit

C.I. soil pipes (sand cast)


having following diameter
with cement joints(1:2):
a) 50 mm
b) 100 mm

115.

WAPDA

m
m

60.81
81.58

Remark
7

1082.31
1615.05
-do-

Special
Special

148.32
222.48

372.74
562.91

C.I.
manhole
covers
having following diameter
with frames:
a) 300 mm
b) 450 mm

Specifica
tion
6
13.3.6.5

C.I. soil specials having


following diameter with
cement joints (1:2):
a) 50 mm
b) 100 mm

116.

Rate (Rs)
Labour Composite
4
5

13.3.7

each
each

152.28
198.75

13 - 24

569.83
1033.86

WCSR-2013 (Zone-2)

SECTION 14 ROAD AND ROAD STRUCTURES

SECTION- 14

ROAD AND ROAD STRUCTURES


1.

Rates for all finished works shall include the removal of surplus debris, unused
material and by products.

2.

The composite rates shall constitute compensation for the completed items of works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished works.

Sr.
No.

Description

Unit

Rate (Rs)
Labour Composite
4

Specifi
cation

Remark

EARTH WORK
1.

Earth work in all types of


soils except rock for
embankment lead upto
150m & lift upto 1.50m
including
ploughing
mixing with blade or disc
harrow or other suitable
equipment compaction by
mechanical
means
complete at optimum
moisture content and
dressing to designed
sections.

cum

167.67

2.

Add extra to item No.1


above for hilly or broken
areas
not
requiring
blasting.

cum

31.44

-do-

3.

Extra for every 150m


additional lead or part
thereof for earth work all
kind of soil (including
gravel, shingle or rock).

cum

42.12

-do-

4.

Add for every


300mm lift.

extra

cum

10.68

-do-

5.

Excavation in foundation
of buildings, bridges &
other structures including
dag belling, dressing,
refilling with excavated
earth including watering
and ramming lead upto
30 metres and lift upto
1.5 metres.

cum

226.92

-do-

6.

Earthwork excavation in
all types of soils dressed
to designed sections
grades & profiles and

cum

154.28

14.1
to
14.6

WAPDA

14 - 1

605.42

14.1
to
14.6
&
14.20

WCSR-2013 (Zone-2)

SECTION 14 ROAD AND ROAD STRUCTURES

Sr.
No.
1

Description

Unit

2
excavated
material
disposed off & dressed
lead upto 15 metres.

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6
&
14.20

Remark
7

SUB-BASE COURSE
7.

Sub-base
course
of
bricks on edge 115 mm
'thick'.

cum

552.92

4848.42

14.8

8.

Sub-base
course
of
bricks ballast including
compaction to required
camber & grade

cum

341.19

1480.62

-do-

9.

Sub-base course of pit


run
gravel
(granular
material)
including
placing,
mixing
&
compaction to required
camber and grade.

cum

339.04

2997.40

14.7

BASE COURSE
10.

Base course of hand


crushed stone aggregate
including
mixing,
spreading to required
depth & compaction of
the base course material
filling voids with stone
dust with the help of
sprinkling
water
as
specified.

cum

509.70

2486.66

14.9
to
14.10

11.

Base course of machine


crushed stone aggregate
as specified.

cum

339.04

2938.92

-do-

SURFACING
12.

Surface treatment:

14.14

a) First coat

Sqm

13.10

284.78

b) Second coat

sqm

7.75

138.41

c) Third coat

Sqm

6.67

157.17

13.

Resurfacing of existing
roads.

Sqm

12.44

226.09

-do-

14.

Priming coat using 0.5


litres kerosine oil &
0.5 kg. binder per sqm.

sqm

12.76

82.37

14.12

WAPDA

14 - 2

WCSR-2013 (Zone-2)

SECTION 14 ROAD AND ROAD STRUCTURES

Sr.
Description
No.
1
2
15. Tack coat using 0.7 kg. of
bitumen per sqm.
16.

17.

Unit
3
sqm

Rate (Rs)
Labour Composite
4
5
12.76
87.51

Plant mixed bituminous


carpet,
including
compaction and finishing
to
required
camber,
grade & density:

Specifi
cation
6
14.13

Remark
7

14.15
to
14.17

a) 25 mm thick

sqm

185.12

680.95

b) 40 mm thick

sqm

288.24

1075.06

c) 50 mm thick

sqm

357.09

1263.73

Scarifying
old
road
surface including removal
of
debris
within
30 m.

cum

177.98

DISTANCE MARKS
ETC.
18.

Road edging complete

19.

Providing and fixing:

9.73

83.40

14.17
14.33

a) K.M. stone

each

1721.06

4166.05

b) Intermediate post

each

425.61

1217.19

c) Boundary pillars

each

468.22

1462.05

d) Sign post

each

1356.73

5761.13

CONCRETE
20.

Plain cement concrete,


refer Section-5 of this
Schedule.

5.6
&
14.21

21. Reinforced
cement
concrete works, refer
Section-5
of
this
Schedule.

-do-

22. Fabrication
of
steel
reinforcement for cement
concrete, refer Section-5
of this Schedule.

-do-

BRICK WORK
23.

WAPDA

Brick
works,
Section-6
of
Schedule.

refer
this

6.1
to
6.5
14 - 3

WCSR-2013 (Zone-2)

SECTION 14 ROAD AND ROAD STRUCTURES

Sr.
No.
1

Description

Unit

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Remark
7

STONE WORK
25.

Coursed rubble masonry


dry, refer Section-7 of
this Schedule.

7.32
7.11

26.

Coursed rubble masonry


in cement sand mortar,
refer Section-7 of this
Schedule.

7.0

27.

Stone pitching works,


refer Section-7 of this
Schedule.

7.3

SURFACE RENDERING
28.

Cement pointing and


plaster
works,
refer
Section-10
of
this
Schedule.

10.1 to
10.6

PRESTRESSED
BRIDGES
29.

Rubber bearing

30.

Steel bearing

31.

Prestressed main beam


of specified size:
a) Anchorage cones in
cable for 12 / 0.276"

1.44

each
set of
1 end

3028.00

708.00

b) Sheath 1-9/16" i/d


12/0.276" cable

47.00

c) Halical core for


12 /0.276" cable

8.00

d) H.T. wire for


12 / 0.276" cable

kg.

58.00

e) Assemble, place
attach 12 / 0.276"
cable.

156.25

172.25

per
cable

234.53

889.18

g) Inject cable with


cement grout

13.84

48.50

h) Cut off projecting


wire end

per
cable

278.41

313.06

Stress cables with


jack on both ends

14.23
-do-

-doper set

f)

WAPDA

cum

14 - 4

WCSR-2013 (Zone-2)

SECTION 14 ROAD AND ROAD STRUCTURES

Sr.
No.
1

2
Make good
recesses each end
of the beam with
type 'A' concrete
and cure.

3
each

Rate (Rs)
Labour Composite
4
5
696.02
956.32

Lift Transport &


placing beams in
position upto
30 metres length.

each

14614.48

26744.65

456.59

754.71

14.24

each

651.18

1376.46

14.28

1361.54

2086.58

14.30
to
14.32

Description
i)

j)

32.

Expansion joints.

33.

Rain water out lets.

35.

R.C.C. railing.

WAPDA

Unit

14 - 5

Specifi
cation
6

Remark
7

WCSR-2013 (Zone-2)

SECTION 15 LINING OF CANALS

SECTION- 15

LINING OF CANALS
1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.

Sr.
No.
1
1.

Description

Unit

Formation, dressing and


preparing sub-grade:
sqm

74.04

b) side slope

sqm

103.05

sqm

177.75

Stabilized
layer
of
cement sand ratio 1:30,
50mm thick on slope.

3.

Cement plaster
thick ratio 1:3

10mm
129.57

189.92

b) side slope

sqm

162.32

222.67

13mm

6.

7.

WAPDA

Cement plaster
thick ratio 1:6

-do-

-dosqm
sqm

b) side slope

Remark

-dosqm

a) bed

5.

238.53

a) bed

Cement plaster
thick ratio 1:5

Specifi
cation
6
15.1

a) bed

2.

4.

Rate (Rs)
Labour Composite
4
5

129.57
162.32

185.45
218.20

40mm

-do-

a) bed

sqm

162.32

272.20

b) side slope

sqm

202.84

312.72

Tiles lining (300 x 150 x


50mm) in 1:5 cement
sand mortar:

-do-

a) bed

cum

2025.68

5767.53

b) side slope

cum

2316.90

6058.75

Tiles lining (300 x 150 x


50mm) in 1:3 cement
sand mortar:

-do-

a) bed

cum

2025.68

6226.47

b) side slope

cum

2316.90

6517.69

15 - 1

WCSR-2013 (Zone-2)

SECTION 15 LINING OF CANALS

Sr.
Description
No.
1
2
8. Brick, lining (230 x 115 x
75mm) in 1:5 cement
sand mortar:
a) bed
b) side slope
9.

11.

WAPDA

cum
cum

Rate (Rs)
Labour Composite
4
5

2025.68
2316.90

Specifi
cation
6
15.1

Remark
7

7099.57
7390.79

Brick, lining (230 x 115 x


75mm) in 1:3 cement
sand mortar:
a) bed
b) side slope

10.

Unit

-do-

cum
cum

2025.68
2316.90

7558.48
7849.70

Cement concrete lining in


1:3:6 (100 mm thick).

-do-

a) bed

cum

1690.27

5810.79

b) side slope

cum

1981.50

6102.01

Cement concrete lining in


1:2:4 (3000 psi) by
Mechanical
means
(100 mm thick).

-do-

a) bed

cum

1938.17

6993.99

b) side slope

cum

2261.49

7317.31

15 - 2

WCSR-2013 (Zone-2)

SECTION 16 SHEET PILING

SECTION- 16

SHEET PILING
1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and equipment required for the finished work.

Sr.
No.
1

Description

Unit

1.

Cutting
Larson
piles.

2.

Cutting universal piles.

3.

Specific
ation
6

per cut

210.12

per cut

310.98

Driving steel piles 7.50 to


9.25 m.

sqm

480.95

4.

Driving steel piles more


than 4.50 m and less
than 7.50 m.

sqm

473.99

-do-

5.

Driving steel piles 4.50 m


and under.

sqm

346.19

-do-

6.

Dollying piles.

each

264.39

-do-

7.

Drilling holes in piles by


hand.

each

27.74

-do-

8.

Raising and
machine.

10360.69

-do-

9.

Turning machine 90

job

4929.14

-do-

10

Turning machine 135

job

6207.15

-do-

11.

Turning machine 180

job

8434.41

-do-

12.

Traveling machine (light)

415.45

-do-

13.

Loading and unloading


piles.

1000
kg

256.89

-do-

14.

Dismantling
machine.

each

15529.45

-do-

15.

Erecting piling machine

each

18379.42

-do-

16.

Carriage
of
piling
machine under different
conditions.

172.27

-do-

WAPDA

Ransom and,
or equivalent

Rate (Rs)
Labour
Composite
4
5

lowering

piling

16 - 1

Remark
7

16.1
to
16.8
which
ever
applies

WCSR-2013 (Zone-2)

SECTION 17 RIVER TRAINING AND DIVERSION WORKS

SECTION- 17

RIVER TRAINING AND DIVERSION WORKS


1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.

Sr.

Rate (Rs)
Labour Composite
4
5

Specifi
cation
6

Description

Unit

1.

Cutting pilchi, farash or


sarkanda
including
carriage within one km.

cum

398.09

17.1
to
17.6

2.

Weaving mattresses

sqm

230.19

-do-

No.

3.

4.

5.

WAPDA

Remark
7
Extra
carriage
would be
admissible
beyond one
km.

a)

Supply and filling


cotton / gunny /
polythene bags 50kg
capacity with sand
or earth, sewing and
stacking in dry.

each
bag

23.73

35.33

-do-

b)

Supply and filling


cotton / gunny /
polythene bags 50kg
capacity with sand
or earth sewing and
laying in position
under water.

each
bag

35.60

47.20

-do-

-do-

a)

Supply and filling


cotton / gunny /
polythene bags 200
to 250 kg capacity
with sand or earth
sewing and stacking
in dry.

each
bag

83.06

145.69

-do-

-do-

b)

Supply and filling


cotton / gunny /
polythene bags 200
to 250 kg capacity
with sand or earth
sewing and laying in
position
under
water.

each
bag

88.99

151.63

-do-

-do-

Carriage of cotton /
gunny / polythene bags
50kg capacity filled with

Rates don't
include
royalty and
carriage of
material to
be filled in
the bags.

-do-

17 - 1

WCSR-2013 (Zone-2)

SECTION 17 RIVER TRAINING AND DIVERSION WORKS

Sr.
No
.
1

Description

Unit

Rate (Rs)
Labour Composite
4

Specifi
cation

Remark

sand or earth:

6.

7.

a) upto 30m

100 no

148.32

b) 30m to 125m

100 no

106.79

c) for subsequent 30m


beyond 125m.

100 no

12.46

Carriage of cotton /
gunny / polythene bags
200 to 250kg capacity
filled with sand or earth:

17.1
to
17.6

a) upto 30m

100 no

593.28

b) 30m to 125m

100 no

444.96

c) Subsequent 30m
beyond 125m.

100 no

71.19

Rolling mattresses to
river edge and floating
after unrolling:

-do-

a) Area of mattress
upto 185 sqm.

sqm

70.01

b)

Area of mattress
185 to 230 sqm.

sqm

111.54

c) Area of mattress
over 230 sqm.

sqm

134.08

100 no

860.26

8.

Sewing empty
bags in sheets.

9.

Making compact pilchi,


farash or sarkanda round
bundles of specified size
for work.

cum

408.77

-do-

10.

Launching the above and


placing in position.

cum

251.55

-do-

11.

Carriage within 150 m:

12.

WAPDA

cement

929.85

-do-

-do-

a) Boulders 230 mm and


above

cum

758.21

b) Over size shingle 75


mm to 230 mm

cum

507.25

c) Mix graded shingle.

cum

601.59

Providing and Weaving


wire netting or wire crates
with G.I. wire gauge 10:

-do-

a) 150 mm mesh

sqm

116.13

181.05

b) 100 mm mesh

sqm

154.85

252.22

17 - 2

If different
wire is used
the cost of
wire can be
changed
accordingly.
WCSR-2013 (Zone-2)

SECTION 17 RIVER TRAINING AND DIVERSION WORKS

Sr.

14.

Filling bricks crates and


hand packing.

cum

452.67

Specifi
cation
6
17.1
to
17.6
-do-

15.

Filling stone
crates.

wire

cum

628.28

-do-

16.

Laying shingle on top of


bund including carriage of
material within 90 m.

cum

209.43

-do-

17.

Dumping shingle spawls


and boulders including
carriage of material within
90 m.

cum

366.65

-do-

18.

Dumping stone by boat


including loading into
boat lead within 90 m.

cum

628.88

-do-

19.

Extra for anchoring boat.

cum

42.12

-do-

20.

Tipping wire crates.

cum

418.86

-do-

21.

Providing
Pilchi
revetment
including
carriage upto one km.

sqm

64.07

159.04

-do-

22.

Surface protection by
providing
pilchi
mattresses carriage upto
one km.

sqm

185.10

260.10

-do-

23.

Providing Pilchi sarkanda


or farash pitching on
slope.

sqm

127.56

1435.76

-do-

24.

Constructing
groynes
made of wooden vertical
stakes 175mm to 300mm
dia.,
300mm
apart,
average lead one km.

No.

1
13.

WAPDA

Description
Filling
crates.

2
bricks-bats

in

Unit
in

3
cum

Rate (Rs)
Labour Composite
4
5
224.26

Remark
7

17.7

a) Height upto 1.5m in


single raw.

sqm

150.34

200.61

b) Height upto 3.0m in


double raw

sqm

256.15

311.41

17 - 3

WCSR-2013 (Zone-2)

SECTION 18 OUTLETS

SECTION- 18

O U T L E T S
1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.

Sr.
No.
1
1.

2.

Description

Unit

Rate (Rs)
Labour Composite
4
5

Earth work for outlets


excavation,
refilling
ramming and puddling for
following discharges:
a) upto 1.5 cumecs.

job

1483.20

b) 1.5 to 3.0 cumecs.

job

1957.82

c) 3.0 to 5.5 cumecs.

job

2966.40

d) 5.5 to 10.0 cumecs.

job

4004.64

e) over 10 cumecs.

job

5932.80

Dismantling Outlets:

Specifi
cation
6

Includes
consolidation
of earth after
refilling.

3.1
to
3.3

These rates
are for
dismantling
and removal
of material
and does not
include
earthwork for
which rates
are given in
item No. 1
above.

each

1483.20

b) A.P.M. or O.F. Height


upto 600 mm

each

2224.80

c) A.P.M. or O.F. Height


from
600mm
to
915mm

each

2966.40

d) A.P.M. or O.F. Height


above 915 mm.

each

3708.00

e) Tail cluster bifurcation

each

2224.80

f)

Tail cluster trifurcation

each

2966.40

g) Tail cluster quadrification

each

3708.00

3.

Constructing temporary
A.P.M. bricks block and
fixing at site.

each

502.51

4.

Dismantling wall taking


out temporary A.P.M.
bricks block and fixing
Iron block and rebuilding
dismantled walls.

each

1290.38

3.2

5.

Dismantling walls and


fitting iron block of O.F.
outlet.

each

1290.38

3.1 to
3.3

WAPDA

18 - 1

2.1
to
2.5

a) old types such as


K.G.O: orifices etc.

821.34

Remark

6.1 to
6.5

WCSR-2013 (Zone-2)

SECTION 18 OUTLETS

Sr.
No.
1
6.

Description

Unit

2
Constructing, watching &
removing bund for outlet
built in running water
depth:

Rate (Rs)
Labour
Composit
e
4
5

a) Upto 915 mm

each

2966.40

b) Above 915 mm

each

4004.64

Specifi
cation
6
6.1 to
6.5

7.

Adjusting of tail cluster by


dismantling
and
rebuilding throat walls.

each

816.75

1293.35

3.1 to
3.3,
6.1 to
6.5 &
18

8.

Adjusting of an A.P.M.
outlet
including
dismantling
and
rebuilding.

each

1587.02

2331.18

-do-

9.

Extra labour in fixing


A.P.M. and O.F. outlets
blocks including dressing
of brick for channel
depth:
each

1522.75

1657.64

b) 1.0 to less than1.5m

each

1142.06

1276.95

c) 0.75 to less than1.0m

each

913.65

1048.54

d) 0.50 to less than 0.75m

each

761.38

869.84

e) Less than 0.50 m

each

609.10

691.15

10.

Repairing
damaged
reducing collar of Hume
Pipe Outlets.

each

502.51

711.92

11.

Laying iron
outlets.

2999.82

20.5

12.

Hoisting and placing R.C.


slab or stone in position
on outlets or W.C.
culverts.

each

571.53

5.9.4

13.

Fixing
pipe
outlets
including back filling of
earth and pudding for the
portion:

WAPDA

of

-do-

a) 1.5m

pipes

Remark

5.9 &
18

20.5

a) Under bank

389.51

426.91

b) Under road beyond


bank.

175.71

213.12

18 - 2

The rates do
not include
cost of pipe.

WCSR-2013 (Zone-2)

SECTION 18 OUTLETS

Sr.
No.
1
14.

15.

WAPDA

Description

Unit

Rate (Rs)
Labour Composite
4
5

Removing pipe outlets


refilling
earth
and
pudding for the portion:

Specifi
cation
6

Remark
7

2.1 to
2.5 &

a) Under bank

326.30

b) Under road beyond


bank

124.59

3.1 to
3.3

Changing pipe outlets


(removing one pipe and
replacing it at the same
site with another pipe)
complete with earth and
pudding for the portion:
a) Under bank

552.66

590.07

b) Under road beyond


bank

238.00

275.41

18 - 3

2.1 to
2.5
&
3.1 to
3.3
&
20.5

The rates do
not include
cost of pipe.

WCSR-2013 (Zone-2)

SECTION 19 SINKING OF WELLS

SECTION- 19

SINKING OF WELLS
1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.

3.

Wells curbs to be laid at spring level or as deep as possible.

4.

If plant is available and is supplied by the authority at site of work hire charges will be
recoverable from the contractor.

5.

The wages of crew if supplied by the authority to work the plant will also be recovered
from the contractor in addition to above charges.

6.

The stores if supplied will be recovered at actual cost plus supervision and storage
charges, etc.

Sr.
Description
No.
1
2
1. Excavation of well in dry
upto 6.0 metres below
ground level and disposal
of soil within 30 metres.

Unit
3

Rate (Rs)
Labour Composite
4
5

a) In ordinary soil or sand


i) From 0.0 metre to
1.50 metres depth

Cum

123.41

ii) From 1.5 to 3.0


metres depth

-do-

127.18

iii) From 3.0 metres to


4.75 metres depth.

-do-

146.02

iv) From 4.75 metres


to 6.0 metres depth.

-do-

169.57

i) From 0.0 metre to


1.50 metres depth

-do-

150.73

ii) From 1.5 to 3.0


metres depth

-do-

155.44

iii) From 3.0 metres to


4.75 metres depth.

-do-

174.28

iv) From 4.75 metres


to 6.0 metres depth.

-do-

193.12

Specifi
cation
6
2.1 to
2.8
which
ever is
applica
ble

Remark
7

b) In hard soil

WAPDA

19 - 1

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

SECTION - 20

MISCELLANEOUS
1.

Composite rate for all finished works include the removal of surplus debris, unused
material and by products.

2.

The composite rates constitute full compensation for the completed items of the works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished work.

Sr.
No.
1

Description

Unit

Rate (Rs)
Labour
Composite
4
5

Specific
ation
6

Remark
7

JUNGLE CLEARANCE
1.

Cutting and removing trees


within a distance of 30m
for girth size;

20.2.1
to
20.2.2

a) Upto 750mm

each

964.29

b) From 750mm to 1.75m

each

1607.15

2.

Uprooting stumps and


removing within a distance
of 30 m for 750mm to
1.75m girth.

each

1186.56

3.

Jungle
clearance
removing with 30m.

and

-do-

-do-

a) Light

100 sqm

89.77

b) Thick

100 sqm

208.95

IRON &
STEEL/ALUMINUM
WORK
4.

Small iron work such as


gusset
plates,
knees,
bends, stirrups, straps,
rings,
etc.
including
cutting, drilling, riveting,
handling, assembling and
fixing
but
excluding
erection in position.

kg

70.25

20.3.1 to
20.3.17

5.

Fabrication of heavy steel


work with angles, tees, flat
iron and sheet iron for
making trusses, girders,
tanks
etc.
including,
cutting, drilling, riveting,
handling, assembling and
fixing
but
excluding
erection in position.

kg

32.78

-do-

6.

Erection and fitting in


position or iron trusses,
staging of water tanks, etc.

kg

22.27

-do-

WAPDA

20 - 1

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Rate (Rs)
Labour
Composite
4
5

Specific
ation
6

Description

Unit

7.

Fixing G.I. sheets including


riveting.

sqm

140.97

20.3.1 to
20.3.17

8.

Erecting G.I. tanks upto


6.50m height.

kg

11.42

-do-

9.

Erecting and fixing in


position rolled steel beams
or old rails in roofs etc.

kg

6.53

-do-

10.

Erecting
rolled
steel
beams or rail section for
posts, etc. (other than in
roof).

kg

2.97

-do-

11.

Making bolts and nuts of


iron rods.

kg

44.64

12.

Cutting rails, rolled steel


joists and beams with
hacksaw:
a) Upto 150 mm
b) Above 150 mm

143.64

-do-

-do-

Per cut

115.54

steel

Per
bend

199.06

Per cut

13.

Cutting rails or rolled steel


beams of size below
150mm.

14.

Bending
rolled
beams or rails.

15.

Fixing handles
hammers.

iron

each

61.97

-do-

16.

Drilling holes in plates upto


13mm thick per 25mm
or part thereof.

each

53.33

-do-

17.

Extra for drilling holes in


plates over 13mm thick per
25mm or part thereof.

each

26.13

-do-

18.

Riveting 3mm

each

6.96

-do-

19.

Cutting out rivets all sizes.

each

22.37

-do-

20.

Fitting and erection


gutters of sheet iron.

33.50

21.

Cutting and fixing iron bars


for barred windows.

Per bar

42.29

-do-

22.

Cutting G.I. sheet.

each cut

27.16

-do-

23.

Notching web or foot of


rails post for housing rail
beams.

WAPDA

of

-do232.47
348.01

to

Remark

-do-

512.69

67.65

-do-

-do-

545.87

Per
notch

20 - 2

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
24.

Rate (Rs)
Labour
Composite

Specific
ation
6
20.3.1 to
20.3.17

Description

Unit

2
Hoop iron netted trellis
work fixing with nails.

3
sqm

4
490.13

25.

Fixing zinc iron or G.I.


sheet on table tops.

sqm

156.83

26.

Making and fixing steel


grated doors complete with
locking arrangement angle
iron frame 50x50x10mm
and 20mm square bars at
100mm center to center.

sqm

1927.94

10627.16

-do-

Size:
2.134m x
1.220m
(7 x 4)

27.

Making and fixing steel


grated door with 2.0mm
thick sheeting including
angle
iron
frame
50x50x10mm and 20mm
square bars 100mm center
to center with locking
arrangement.

sqm

2088.06

12174.56

-do-

Size:
2.134m x
1.220m
(7 x 4)

28.

Making and fixing grating


in opening including fixing
at site with flat iron
50x10mm
and
20mm
square bars at 100mm
center to center.

sqm

1125.16

7138.42

-do-

Size:
1.524m x
2.439m
(5 x 8)

29.

Providing and fixing steel


doors with grill work on
outer face of the door as
per approved design of the
Engineer Incharge

sqm

1919.39

9264.56

-do-

Size:
2.134m x
1.220m
(7 x 4)

30.

Providing and fixing steel


doors without grill work on
outer face of the door as
per approved design of the
Engineer Incharge

sqm

1406.72

7062.43

-do-

Size:
2.134m x
1.220m
(7 x 4)

31.

Providing and fixing lifted


shutter for garages etc, as
per approved design of the
Engineer Incharge

sqm

867.77

10679.61

-do-

Size:
2.439m x
2.744m
(8 x 9)

32.

Providing and fixing steel


window glazed and fixed
(not openable) of standard
frame "Z" section with
3mm glass pan as per
approved design of the
Engineer Incharge.

sqm

717.37

5090.71

-do-

Size:
1.829m x
1.220m
(6 x 4)

33.

Providing and fixing steel


windows glazed openable

sqm

736.02

6498.14

-do-

WAPDA

20 - 3

Remark
7

-do-

-do-

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Rate (Rs)
Labour
Composite

Specific
Remark
ation
5
6
7
20.3.1 to
20.3.17
which
ever is
applicab
4778.26
Size:
-le
1.829m x
1.220m
(6 x 4)

Description

Unit

34.

Providing
and
fixing
window grill with angle iron
frame with 10mm sq. iron
bars at 75mm centre to
centre as per approved
design of the Engineer
Incharge.

sqm

465.65

35.

Providing and fixing wire


gauze SWG 144 fixed to
steel windows as per
approval of the Engineer
Incharge.

sqm

629.47

1013.94

-do-

Size:
915mm x
1.524m
(3 x 5)

36.

Providing and fixing steel


windows (not openable) of
standard tabular frame 40
x 40mm and shutters 40 x
25mm as per approved
design of Engineer in
chief.

sqm

1261.35

3885.23

-do-

Size:
1.829m x
1.220m
(6 x 4)

37.

Providing and fixing steel


windows (openable) of
standard tabular frame 40
x 40 mm and shutters 40 x
25 mm as per approved
design of Engineer in
chief.

sqm

927.23

4214.59

-do-

Size:
1.829m x
1.220m
(6 x 4)

38.

Providing
and
fixing
window grills without angle
iron frame with 10mm sq.
iron bars at 75mm centre
to centre as per approved
design of Engineer.

sqm

869.59

3705.55

-do-

Size:
1.829m x
1.220m
(6 x 4)

39.

Providing and fixing steel


grills to openable steel
windows as per drawing
No.CDO(W) 301-5B/215.

sqm

803.15

3096.68

-do-

40.

Providing and fixing wire


gauge 144 mesh square in
openable tubular window
and c-window as per
drawing No. CDO(W) 3015B/215.

sqm

822.44

1646.47

-do-

41.

Providing and fixing steel


frame for door of M.S.
angle iron 50x50x6mm,
M.S. flat 64x6mm and M.S

sqm

1097.82

4259.05

-do-

WAPDA

of standard "Z" section


frame as per approved
design
of
Engineer
Incharge.

20 - 4

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Rate (Rs)
Labour
Composite
4
5

Specific
ation
6
20.3.1
to
20.3.17
which
ever is
applicable

Description

Unit

2
strap
50x30x3mm
at
750mm c/c as per drawing
No. CDO(W) 301-5B/93.

42.

Making grooves 25mm x


13mm.

24.98

27.28

43.

Providing and fixing of


bent metal 16 SWG frame
345mm wide for door size
915mm x 2.134m (3' x 7')
complete in all respect.

no

50.71

5920.38

44.

Providing and fixing of


bent metal 16 SWG frame
250mm wide for door size
760mm x 2.134m (2.5' x
7') complete in all respect.

no

50.71

3963.82

45.

Providing and fixing steel


frame
of
angle
iron
50x50x6mm complete in
all respect.

159.56

880.90

46.

Providing
and
fixing
aluminum natural anodized
openable hinged windows
without glazing.

sqm

767.61

5482.90

-do-

47.

Providing
and
fixing
aluminum natural anodized
openable hingd doors
without glazed.

sqm

1151.57

5903.90

-do-

-do-

48.

Providing
and
fixing
aluminum natural anodized
fly screen shutters.

sqm

246.02

1939.44

-do-

-do-

49.

Providing
and
fixing
aluminum natural anodized
openable double leaf door
hinged without glazing.

sqm

1151.37

6820.64

-do-

-do-

50.

Providing
and
fixing
aluminum natural anodized
fixed panel without glazing.

sqm

669.72

3830.78

-do-

-do-

51.

Providing
and
fixing
aluminum natural anodized
louvers.

sqm

613.45

8036.65

-do-

-do-

52.

Providing and fixing door


lock natural anodized.

each

319.50

2639.25

-do-

53.

Providing
and
aluminum
door
(single
action)
anodized.

each

199.69

4201.26

-do-

WAPDA

fixing
closer
natural

20 - 5

Remark
7

Analysis:
one (1)
sqm.

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Rate (Rs)
Labour
Composite
4
5

Specific
ation
6

Description

Unit

54.

Providing
and
fixing
aluminum window (sliding)
with
fly
shutter
18SWG/1.2mm
section
shampean or any other
colour and green or blind
glass 5mm thick.

sqm

246.57

7066.78

7
Analysis:
one (1)
sqm.

55.

Providing
and
fixing
aluminum door (sliding)
shampean or any other
colour and green or blind
glass 5mm thick.

sqm

188.04

5981.05

-do-

56.

Providing and fixing door


closer
(double
action)
natural anodized.

each

399.38

14433.88

57.

Providing
and
fixing
fabricated Iron entrance
Gate as per Drawing No.
CDO(W)/501/5A/36.

each

25937.36

79334.64

58.

Providing and fixing G.I.


1.5m length 50 x 50 x
6mm angle iron post for
barbed
wire
fencing
around switch yard duly
fixed in position (Dwg
No.PD-W/TB-126).

each

334.21

1359.45

-do-

59.

Same as above but post


length 750mm.

each

334.21

1016.45

-do-

60.

Filling expansion joints


13mm thick for 100mm to
150mm deep slabs with
bitumen mixed with sand
and saw dust.

29.07

108.54

-do-

61.

Providing and fixing steel


ladder for overhead tank
made of angle iron 50 x 50
x 6mm with 15mm MS
bars step 375mm post
including side supports of
angle iron 50 x 50 x 6mm
complete in all respects.

1238.21

4292.90

-do-

62.

Providing and fixing in


position rolled steel beam
100 x 100 x 6mm.

533.14

1701.17

-do-

63.

Providing and fixing side


hooks
used
in
the
construction of overhead
tank.

each

165.43

215.20

-do-

WAPDA

20 - 6

Remark

20.3.1
to
20.3.17
which
ever is
applicable

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Rate (Rs)
Labour
Composite
4
5

Specific
ation
6
20.3.1
to
20.3.17
which
ever is
applicable

Description

Unit

64.

Providing and fixing 15mm


bar hook for fan.

each

152.28

192.84

65.

Providing and fixing angle


iron steps (40 x 40 x 6mm)
1.5m long.

each

378.01

1100.08

66.

Providing and fixing cable


try 3-way of MS angle iron
including anchor bolts,
painting 3 coats and fixing
in cable trench.

each

1192.35

2646.54

-do-

67.

Laying asphaltic mixture in


13mm wide expansion
joint 200-230mm deep
including cost of material
and labour.

39.16

193.53

-do-

68.

Providing
and
fixing
aluminum joint cover (gole)
75mm size on expansion
joint.

35.94

214.02

20.3.2

69.

Supply and fix approved


quality
of
aluminum
channel 40 x 13 x 13mm
size, U shape
complete
in
all respects including
labour and material upto
12m height.

51.92

122.97

-do-

70.

Supply and fix in position


approved
quality
of
aluminum angle iron size
40 x 13mm complete all
labour and material upto
12m height.

51.92

113.32

-do-

71.

Providing and fixing of MS


dowel bar of 15mm
1.25m long including PVC
/wooden sleeves complete
as
per
drawing
No.PDW/TV-420.

each

51.92

258.52

-do-

72.

Providing
and
fixing
platform of 40 x 5mm GI
strap flat and batton or GI
tee iron 50 x 100 x 5mm,
1.75m long fixed in
position complete in all
respects as per drawing
No.PDW/TB-626.

sqm

14111.70

20121.67

-do-

WAPDA

20 - 7

Remark
7

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
73.

Rate (Rs)
Labour
Composite
4
5
2692.92
5751.98

Specific
ation
6
20.3.2

Description

Unit

2
Providing / erection of MS
plate 14 SWG size 600m
(trench cover) including
welded with MS angle iron
25 x 25 x 3mm fixed in
position as per drawing
No.PDW/TB-625 complete
in all respects.

3
sqm

74.

Providing and fixing GI


angle iron cable rack tray
1-way including anchor
bolts etc. complete as per
drawing No.PDW/TB-1615

each

789.43

1046.45

-do-

75.

Fixing in position of
foundation
bolts
duly
assembled in template
which will be provided by
the Contractor including
welding the bolts with steel
caps as per drawing
No.PDW TC-263.

each

108.91

236.23

20.3

76.

Providing and fixing 15m


9.75m long malleable iron
steps as per design.

each

76.14

292.29

20.3.7

77.

Providing and fixing C


section curtain railing over
100 x 25mm Deodar wood
strip.

103.84

573.93

-do-

78.

13 x 13mm MS Square
bar, pipe railing having
pipe 40mm welded with
MS flat 40 x 5mm.

2718.06

4866.02

-do-

79.

Providing
and
fixing
WAPDA monogram on the
main
entry
gate
of
G/station prepared from 16
gauge MS sheet.

each

731.92

1531.15

-do-

Remark
7

FENCING
80.

WAPDA

Providing
and
fixing
barbed wire fencing with 4
horizontal and 2 cross
wires with RCC 1:2:4 posts
1700 x 150 x 300mm
(2.5m center to center)
reinforced with 4 Nos
10mm vertical bars and
3mm stirrups 300 mm
center to center complete
in all respects.

-do-

20 - 8

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Rate (Rs)
Labour
Composite
4
5
178.22
644.25

Specific
ation
6

Description

Unit

2
a) Without
cement
concrete base.

3
m

b) In cement
base 1:4:8.

concrete

255.98

905.49

81.

Providing and fixing 4 rows


barbed
wire
fencing
around switch yard G.I.
barbed wire 14 SWG, 2
ply, 4 points fixed on G.I.
angle iron 50 x 50 x 6mm
posts complete (Excluding
cost of angle iron post).

97.15

212.56

20.3.7

82.

Providing and fixing 7 rows


barbed
wire
fencing
around switch yard G.I.
barbed wire 14 SWG,
2 ply, 4 points fixed on
G.I. angle iron 50 x 50 x
6mm
posts
complete
(Excluding cost of angle
iron post).

111.60

314.06

-do-

83.

Fixing and grouting angle


iron post (only labour rate)
provided
by
the
department in pocket with
PCC 1:2:4 as per drawing
No.PDW/TB-786.

each

95.76

112.57

20.3.2

84.

Fixing barbed wire fencing


provided
by
the
department complete as
per drawing No.PDW/TB786.

27.27

85.

Providing / fixing GI earth


strip 30 x 3mm for switch
yard fencing frame with
allied bolt nuts etc. as per
drawing No.PDW/TS-786

each

202.09

449.62

20.3.2

86.

Providing and fixing of


tensioning
rod
3.0m
interval in the barbed wire
fencing posts as per Dwg
No. 0-3-GS-5.

each

161.11

584.32

20.4

87.

Providing and fixing of


315mm long 13mm M.S
anchor bolt with nuts and
washers complete in all
respects for corner post of
barbed wire as Dwg No.
0-3-GS-5.

each

27.84

115.85

-do-

WAPDA

20 - 9

Remark
7

20.3.7

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
88.

Description

Unit

2
Providing and fixing of
boundary fencing barbed
wire 14 SWG, 2ply, 4 point
(8 rows horizontal + 2
diagonal) complete in all
respects as per Dwg No.
0-3-GS-5.

3
m

Rate (Rs)
Labour
Composite
4
5
72.30
255.74

Specific
ation
6
20.4

Remark
7

SURVEYING
89.

Supplying
bamboo
bundles 3m to 3.75m with
iron shoes and flags
375mm square.

each

31.73

187.08

90.

Supplying wooden pegs


for leveling 40mm
150mm long.

each

3.96

12.08

91.

Supplying wooden pegs


for alignment 50mm to
75mm 150mm long.

each

7.92

30.30

92.

CANAL AND ROADS

20.5

Fixing floating spurs with


material
from
canal
plantation within 1.5km
lead for depth:

20.5.1

a)
b)
c)
d)
93.

WAPDA

Upto 600 mm
600 to 915 mm
915 to 1.25 m
Above 1.25 m

Staking and bushing from


canal plantation Royalty to
be
paid
to
Forest
Department or cost to
private owner if and when
required lead within 1.5km.
A
i) Cutting and supply
unsharpened
pegs
1.0m long 75-150mm
within 1.6km lead.
ii) Driving pegs 1.0m
long 75-150mm
(Driven) 300mm below
the available bed or
ground (average)
iii) Tying pegs with Munj,
patha, ban (on line,
including tying around
the pegs).

each
each
each
each

23.24
30.22
37.82
71.87
20.5.2

No

8.52

No

7.99

per
30 m
of
1 row

47.17

20 - 10

11.30

66.35

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Description

Unit

2
iv) Cutting and supplying
brush wood from canal
plantation or private
owner lead within 1.5km
and wattling between
stake and interwining
(Thickness of wattle
brush wood 300 mm
average).

3
-do-

B
i) Cutting and supplying
sharpened pegs 1.0m
long 75-150mm from
canal plantation lead
within 1.6km
ii) Driving pegs 1.0m long
75-150mm (Driven
375mm
below
the
available bed or ground
(Average)
Iii) Tying pegs with Munj,
patha, ban (one line
including tying around
the pegs).
iii) Cutting and supplying
brush wood from canal
plantation or private
source (lead within
1.5km) and wattling
between stakes and
interwining (Thickness
of wattled brush wood
300mm) (Average)
C
i) Cutting and supplying
sharpened pegs 1.0m
long 75-150mm from
canal plantation lead
within 1.5km (Average)
ii) Driving pegs 1.5 m long
75-150mm (Driven
450mm
below
the
available bed or ground
(Average)
iii) Tying pegs with Munj,
patha, ban (one line
including tying around
the pegs).
iv) Cutting and supplying
brush wood from canal
plantation or private
source
(lead
within1.5km)
and
wattling
between
stakes and interwining
WAPDA

Rate (Rs)
Labour
Composite
4
5
879.22
1133.11

No

9.65

No

12.44

per
30 m
of
1 row
per
30 m
of
1 row

47.17

66.35

1055.97

1335.26

No

12.37

15.74

No

13.92

per
30 m
of
1 row
-do-

47.17

66.35

1163.44

1469.39

20 - 11

Specific
ation
6

Remark
7

12.67

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Description
2
(Thickness of wattled
brush wood 305mm)
(Average)
D
i) Cutting and supplying
sharpened pegs 1.75m
long 75-150mm from
canal plantation lead
within 1.5km (Average)
ii) Driving pegs 1.75m
long
75-150mm

(Driven 525mm below


the available bed or
ground (Average)
iii) Tying pegs with Munj,
patha, ban (one line
including tying around
the pegs).
iv) Cutting and supplying
brush wood from canal
plantation or private
source (lead within
1.5km) and wattling
between stakes and
intertwining (Thickness
of wattled brush wood
300mm) (Average)
E
i) Cutting and supplying
sharpened pegs 1.752.5m long 100-200mm
from canal plantation
lead
within
1.5km
(Average)
ii) Driving pegs 1.75-2.5m
long 100-200mm
(Driven 600mm below
the available bed or
ground (Average)
iii) Tying pegs with Munj,
patha, ban (one line
including tying around
the pegs).
iv) Cutting and supplying
brush wood from canal
plantation or private
source (lead within
1.5km) and wattling
between stakes and
intervening (Thickness
of wattled brush wood
300mm) (Average)

WAPDA

Rate (Rs)
Labour
Composite
4
5

Unit
3

No

13.12

No

15.40

per
30 m
of
1 row
per
30 m
of
1 row

47.17

66.35

1280.66

1612.64

No

15.10

19.27

No

16.89

per
30 m
of
1 row
per
30 m
of
1 row

47.17

66.35

1500.46

1858.47

20 - 12

Specific
ation
6

Remark
7

16.83

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
94.

Description
2
Staking with bamboo from
market and brushing from
canal plantation or private
source (Royalty of brush
wood to be paid to Forest
Department or cost to
private owners if and when
required.
A
i) Supplying bamboo 2.53.0m long 65-125mm .
ii) Sharpening one end of
2.5-3.0m long bamboo
65-125mm
iii) Driving bamboo 2.53.0m long 65-125mm
(Driven 750mm below
the available bed or
ground) (Average).
iv) Tying bamboos 65125mm with munj,
patha, ban (two lines
including tying around
the bamboos).
v) Cutting and supplying
brush wood from canal
plantation or private
source
(lead
within
1.5km) and wattling
between stakes and
interwining) (Thickness
of wattled brush wood
300mm) (Average)
B
i) Supplying bamboo 3.03.75m long 65-125mm
.
ii) Sharpening one end of
3.0-3.75m
long
65125mm .
iii) Driving bamboo 3.03.75m long 65-125mm
(Driven 825mm below
the available bed or
ground) (Average).
iv) Tying bamboos 64127mm with BSWG
No.10 wire two (lines
including tying around
the bamboos and third
tie around the top end
only).

WAPDA

Rate (Rs)
Labour
Composite
4
5

Unit
3

Specific
ation
6
20.5.3

Remark
7

20.5.3
No

186.00

No

7.33

No

13.92

per
30 m
of
1 row

79.88

103.26

per
30 m
of
1 row

2332.37

2722.56

No

218.40

No

8.37

No

15.40

per
30 m
of
1 row

208.81

20 - 13

-do-

1144.81

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Description

Unit

2
v) Cutting and supplying
brush wood from canal
plantation or private
source
(lead
within
1.5km) and wattling
between stakes and
intertwining (Thickness
of wattled brush wood
300mm) (Average)

3
per
30 m
of
1 row

C
i) Supplying
bamboo
No
3.75-4.25m long 65125mm
ii) Sharpening one end
No
of 3.75-4.25m long 65125mm
iii) Driving bamboo 3.75No
4.25m long 65-125mm
(Driven 1.0m below
the available bed or
ground) (Average).
iv) Tying bamboos 65per
125mm with BSWG 30m of
No.10 wire two (lines 1 row
including tying around
the bamboos and third
tie around the top end
only).
v) Cutting and supplying
per
brush wood from canal 30m of
plantation or private 1 row
source (lead within
1.5km) and wattling
between stakes and
interwining) (Thickness
of wattled brush wood
305mm) (Average)
D
i) Supplying
bamboo
4.25-5.0m long 65125mm
ii) Sharpening one end of
4.25-5.0m long 65125mm
iii) Driving bamboo 4.255.0m long 65-125mm
(Driven 1.25m below
the available bed or
ground) (Average).
iv) Tying bamboos 65125mm with BSWG
No.10 wire two (lines
including tying around
the bamboos and third
tie around the top end
only).
WAPDA

Rate (Rs)
Labour
Composite
4
5
2541.71
2969.93

Specific
ation
6

Remark
7

20.5.3
258.00
8.87
17.40

208.81

1144.81

2709.94

3179.46

No

294.00

No

9.67

No

18.88

per
30 m
of 1
row

208.81

20 - 14

20.5.3

1144.81

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Description

Unit

2
v) Cutting and supplying
brush wood from canal
plantation or private
source
(lead
within1.5km)
and
wattling
between
stakes
and
interwening)
(Thickness of wattled
brush wood 300mm)
(Average)

3
per
30 m
of 1
row

E
i) Supplying bamboo 5.0No
6.0m long 65-125mm
ii) Sharpening one end of
No
5.0-6.0m
long
65125mm
iii) Driving bamboo 5.0No
6.0m long 65-125mm
(Driven 1.25m below
the available bed or
ground) (Average).
iv) Tying bamboos 64per
127mm with BSWG 30m of
No.10 wire two (lines 1 row
including tying around
the bamboos and third
tie around the top end
only).
v) Cutting and supplying
per
brush wood from canal 30m of
plantation or private 1 row
source (lead within
1.5km) and wattling
between stakes and
interwining) (Thickness
of wattled brush wood
305mm) (Average)

Rate (Rs)
Labour
Composite
4
5
2988.35
3501.48

11.71
20.88

208.81

1144.81

3275.24

3866.31

513.86

Cutting and supplying


brush wood from canal
plantation or from any
other source within 1.5km.

cum

421.07

96.

Filling brush wood only


thoroughly packed.

cum

209.52

97.

Laying RC hume pipes in


position including jointing:

WAPDA

Remark

20.5.3

366.00

95.

a. 150 - 300 mm
b. 300 - 600 mm
c) 600 - 915 mm

Specific
ation
6

20.5.4
m
m
m

212.49
318.73
375.91

20 - 15

358.24
515.96
667.42

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
98.

Rate (Rs)
Labour
Composite
4
5
208.16
214.63

Specific
ation
6
20.5.5

Description

Unit

2
Fixing
enamelled
iron
gauges flush with masonry
including cost of hooks.

3
m

99.

Placing boundary pillars in


position including digging
pits.

each

60.91

100.

Fixing main line type


distance marks in position
including making 1:3:6
cement concrete base
block
size
355x250x375mm.

each

141.07

101.

Covering road 3-3.75m


wide with 75mm sarkanda
or jungle upto 50m lead.

23.36

20.5.8

sqm

415.09

20.5.9

sqm

351.23

103. Cutting pipes upto 50mm .

Per
cut

57.35

20.6

104. Cutting pipe above 50mm

Per
cut

110.62

-do-

each

77.25

-do-

55.40

-do-

102. a) Gachi pitching 300mm


thick.
b) Gachi pitching done
with silt clearance and
berm dressing.

Remark
7

20.5.6

308.45

20.5.7

HAND PUMPS AND


PRESSURE PIPES

105.

Threading pipe ends 40 to


100 mm.

106.

Assembling
40mm
pressure pipe.

107.

Boring and fixing 40mm


pressure pipe.
a) In ordinary soil
b) In clay
c) In shingle

m
m
m
m

314.44
606.12
898.09

108.

Repair to hand pump


pulling out and refitting.

131.79

-do-

109.

Fixing
hand
(Machine only).

each

319.50

-do-

WAPDA

pump

-do-

20 - 16

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

Description

Unit

2
REST HOUSE
FURNITURE AND FUEL
ETC

Rate (Rs)
Labour
Composite
4
5

Specific
ation
6

110.

Washing Niwar of bed.

per
bed

345.06

361.10

2.7

111.

Washing Durries.

sqm

85.98

89.97

-do-

112.

a: Recaning
Chairs
(Cane)
i) Office chairs, single,
caning seat only
ii) Office chairs, double
caning seat only
iii) Office chairs, single
caning back only
iv) Office chair, double
caning back only
v) Easy chairs, single
caning seat only
vi) Easy chairs, double
caning seat
vii) Easy chair, single
caning back and seat
in one piece only
viii) Easy chairs, double
caning back and seat
in one piece or
couches with caned
area about 1.50 sqm.

ii)
iii)
iv)
v)
vi)

Office chairs, single,


caning seat only
Office chairs, double
caning seat only
Office chairs, single
caning back only
Office chair, double
caning back only
Easy chairs, single
caning seat only
Easy chairs, double
caning seat only

each

272.69

357.79

each

359.95

474.09

each

234.51

277.09

each

359.95

445.05

each

409.03

523.17

each

545.38

772.65

each

1090.75

1431.17

each

1363.44

2272.55

-doeach

272.69

292.71

each

447.21

486.01

each

299.96

316.48

each

359.95

382.48

each

479.93

512.47

each

654.45

712.02

each

222.48

747.56

-do-

113.

Making and fixing


pegs ordinary.

114.

Weaving cot

each

599.07

872.80

-do-

115.

Sweeping chimneys

each

148.32

152.67

-do-

116.

Picture railing including


making fixing and painting.

186.86

543.13

-do-

WAPDA

Hat

-do-

b: Recaning Chairs (plastic)


i)

Remark

20 - 17

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
117.

Rate (Rs)
Labour
Composite
4
5
556.81
612.49

Specific
ation
6
20.7

Description

Unit

2
Flapping G.I. pipes for
bathroom drains.

3
each

118.

Cutting fuel wood from


plantation.

Tonne

144.50

-do-

119.

Splitting fuel wood.

Tonne

317.91

-do-

120.

Burning charcoal including


loading, unloading and
repairing kilns.

Tonne

6607.19

-do-

121.

Filling cement bags with


coal and sewing (including
cost of strings).

cum

576.17

-do-

122.

Ploughing 3 times.

Hectare

4379.88

-do-

123.

Levelling dressing
making lawns.

and

sqm

36.77

-do-

124. Turfing lawns (excluding


cost of turf).

sqm

29.35

-do-

125.

Supplying and fixing iron


grating for fire place.

sqm

122.40

126.

Fixing copper flashing


including cutting of sheets,
grooving and riveting.

77.86

127.

Washing fan frills.

each

119.81

128.

Washing:
i) Table cloth
ii) Napkins, dusters etc.

129.

5689.80

b) Beyond 3.0m depth of


slush

-do-do-

136.52

-do-do-

each
each

49.92
30.35

56.88
Error! Not a
valid link.

Silt clearing 3.0m wells


and removal of slush
outside the compound.
a) Upto 3.0m depth slush

Remark

-do-

each
well
each
well

6927.75
13855.49

SUI GAS
130.

Providing,
laying
and
testing M.S. pipe 100mm
(dia) having 5mm wall
thickness.

273.80

2361.80

20.9

131.

Providing,
laying
and
testing M.S. pipe 50mm
having
4mm
wall
thickness.

194.00

920.00

-do-

WAPDA

20 - 18

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
132.

Rate (Rs)
Labour
Composite
4
5
181.54
394.96

Specific
ation
6
20.9

Description

Unit

2
Providing,
laying
and
testing M.S. pipe 25mm
having
3.25mm
wall
thickness.

3
m

133.

Providing,
laying
and
testing M.S. pipe 19mm
having
3.25mm
wall
thickness.

181.54

353.21

-do-

134.

Providing,
laying
and
jointing reducing elbow
100 x 50mm at 90.

each

144.17

1257.65

-do-

135.

Providing, laying and fixing


/ jointing elbow 100mm
at 90 or 45.

each

144.17

840.09

-do-

136.

Providing, laying and fixing


/ jointing valve 102mm
flanged (China).

each

144.17

3067.05

-do-

137.

Providing, laying and fixing


/ jointing tee/elbow/union
etc. 50mm .

each

99.37

1908.78

-do-

138.

Providing, laying and fixing


/ jointing tee/elbow/union
etc. 25mm .

each

99.37

1011.04

-do-

139.

Providing, laying and fixing


/ jointing tee/elbow/union
etc. 19mm .

each

99.37

291.91

-do-

140.

Providing
and
fixing
peeable regulator for sui
gas network.

each

213.58

658.97

-do-

141.

Providing and fixing sui


gas single burner.

each

427.16

900.39

-do-

142.

Providing and fixing sui


gas double burner.

each

427.16

1331.86

-do-

143.

Providing
and
fixing
cooking range 3 burners /
oven.

each

1281.48

17519.75

-do-

144.

Providing and fixing water


geyser 160 litres (35
gallons) capacity.

each

854.32

15014.32

-do-

145.

Providing and fixing water


geyser 114 litres (25
gallons) capacity.

each

854.32

11293.21

-do-

WAPDA

20 - 19

Remark
7

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
146.

147.

Rate (Rs)
Labour
Composite
4
5
854.32
7117.65

Description

Unit

2
Providing and fixing sui
gas metre for WAPDA
residences.

3
each

Supply and Fixing sui gas


room heater double plate.

each

422.71

14582.71

1882.66

Specific
ation
6
20.9

Remark
7

-do-

OTHER
MISCELLANEOUS ITEMS
148.

Notice board made with


cement plaster 13 mm
thick with 50 mm wide 25
mm
thick
beading
(1.25mx1.50m)

each

1688.68

149.

Hoisting
and
placing
sleepers for centering
including carriage within
30 m.

each

62.41

20.8

150.

Dredging sumps, having


not less than 5 gang men
to be employed for each
shift.

Shift

2966.40

-do-

151.

Repairing
corners
building structures.

of

each

185.89

-do-

152.

Chamfering sides of head


regulators and masonry
walls to increase width.

sqm

655.63

-do-

153.

Fixing "U" bolts in masonry


or
concrete
including
leveling and tying for fixing
angle iron posts.

each

236.32

-do-

154.

Replacing
bricks.

deteriorated

each

24.52

-do-

155.

a) Unwatering by hand
b) Bailing out water by
pump.

cum
cum

78.57
6.19

-do-

156

Repairing
corners
of
bridges
and
other
hydraulic masonry works.

each

380.69

-do-

157.

Breaking
brick
ballast
screening and stacking of
ring size:
a) 50 mm
b) 40 mm
c) 25 mm
d) 20 mm

WAPDA

-do-

cum
cum
cum
cum

628.55
733.30
838.06
942.82
20 - 20

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
158.

Rate (Rs)
Labour
Composite
4
5
97.32

Specific
ation
6
20.8

Description

Unit

2
Fixing broken glasses on
court yard walls, with
cement concrete coping
1:3:6.

3
m

159.

Extra labour for drains of


bathrooms etc.

100.63

-do-

160.

Drilling
trough.

R.C.

each

143.38

-do-

161.

Erecting and casting sunshades of precast R.C.


concrete (upto 1.5x0.8 m)

each

389.59

-do-

162.

Hoisting R.S beams and


wooden
beams
and
placing in position

each

450.00

-do-

163.

Hoisting and placing in


position sal ballies over
roofs.

each

50.71

-do-

164.

Hoisting R.C. battens and


placing in position:

holes

in

a) 1.5 - 1.75 m
b) 1.75 - 2.0 m
c) 2.0 - 2.5 m
d) 2.5 - 2.75 m
e) above 2.75 m
165.

-doeach
each
each
each
each

45.09
67.73
90.28
108.37
135.47

Hoisting and placing in


position R.C. trough:

-do-

a) Upto 3 m
b) 3.0 - 3.3 m
c) 3.3 - 3.7 m
d) 3.7 - 4.0 m
e) 4.0 - 4.3 m
f) 4.3 - 4.6 m
g) 4.6 - 4.9 m
h) 4.9 - 5.2 m
i) 5.2 - 5.5 m
j) 5.5 - 5.8 m
k) 5.8 - 6.1 m

each
each
each
each
each
each
each
each
each
each
each

135.47
180.56
225.84
246.30
270.93
301.04
338.66
387.43
451.55
492.35
541.86

166.

Hoisting placing in position


R.C. shelves.

each

84.86

-do-

167.

Hoisting & placing in


position precast RC latrine
seats.

each

338.66

-do-

WAPDA

Remark

20 - 21

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
168.

Description

Unit

2
Hoisting and placing in
position
R.C.
inverted
battens:

Rate (Rs)
Labour
Composite
4
5

Specific
ation
6
20.8

a) Upto 3m
b) 3.0 - 3.7m
c) 3.7 - 4.0m
d) 4.0 - 4.3m
e) 4.3 - 4.6m
f) 4.6 - 4.9m
g) 4.9 - 5.5m
h) 5.5 - 6.1m

each
each
each
each
each
each
each
each

110.09
220.17
275.22
330.26
367.37
412.82
551.53
825.65

169.

Reinforced
cement
concrete spout including
fixing in position with top
and bottom finishes.

each

609.10

759.92

-do-

170.

Laying 50mm thick sand


and bitumen carpet on top
of foundation of oil tank.

sqm

155.67

353.19

-do-

171.

Cutting holes 100x150mm


in stone or brick or
concrete wall with chisel,
repairing masonry and
removing debris within
30m lead.

Per
hole

304.55

-do-

172.

Cutting grooves in stone


Per
masonry, brick masonry or groove
cement concrete wall and
removing debris within
30m lead.

380.69

-do-

173.

Making 40 x 40mm groove


in wall of stone or brick
masonry in cement for
fixing planks upto 230mm
depth.

Per
blank

253.79

-do-

174.

Drilling holes in stone or


brick masonry upto 5.0m
per 25mm depth.

Per
hole

74.16

-do-

175.

Laying and ramming dry


ballast or Kankar.

cum

838.06

-do-

176.

Petty repairs to fire places.

each

397.06

608.11

-do-

177.

Petty repairs to main


rooms above 10.75 Sq..

each

285.52

369.08

-do-

178.

Petty repairs to small


rooms below 10.75 Sq..

each

142.76

182.58

-do-

WAPDA

20 - 22

Remark
7

WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1
179.

2
Petty repairs to verandah.

3
each

Rate (Rs)
Labour
Composite
4
5
285.52
369.08

180.

Constructing
range as per
design
of
residences
No.120-I/3B

cooking
standard
WAPDA
drawing

each

4484.02

13279.11

-do-

181.

Constructing fire place as


per standard design of
WAPDA
residences
drawing No. 120-I/4B

each

2025.30

3884.54

-do-

182.

Extra charges for using


admixture
for
water
proofing purpose.

Kg

139.19

-do-

183.

Providing
and
thermopore sheet

Description

Unit

laying

Remark
7

-do-

a) 25 mm thick
b) 40 mm thick

sqm
sqm

145.81
145.81

549.92
725.93

184.

Testing samples of water


from laboratory.

each

118.66

311.20

185.

Providing and installation


pumping set type ETA size
75 x 63mm (3x2") speed
about 2900 rpm and 36.5m
(120')
head
including
supply and fixing one No.
motor and starter 15 HP
with one No. voltmeter and
one No. ampere metre and
main switch 60 ampere
500 volts 3 pole on steel
board complete in all
respects
and
other
incidental thereto.

each

2745.63

125228.51

186.

Providing and fixing Razor


barbed wire fencing having
460mm ring at 150mm
centre to centre hanging
on 10mm dia MS bar with
40x40x5mm angle iron
post of 1.0m height
complete.

219.32

772.22

187.

Fabrication, erection, fixing


and installation of Car
Shed of 5 ply fiber glass
sheet with steel structure
made of 18 gauge square
tube 32 x 32 mm side

sqm

103.12

5538.67

WAPDA

Specific
ation
6
20.8

20 - 23

-do-

Analysis
for 4.0m x
2.75m
divided
into 9 Nos
equal size
WCSR-2013 (Zone-2)

SECTION 20 MISCELLANEOUS

Sr.
No.
1

188.

WAPDA

Description

Unit

2
bracing for sheet with MS
flat 25 x 3 mm and
100 mm 16 gauge
vertical post complete in all
respect.

Fabrication, erection, fixing


and installation of Car
Shed of 3 ply fiber glass
sheet with steel structure
made of 18 gauge square
tube 32 x 32 mm side
bracing for sheet with MS
flat 25 x 3 mm and 75 mm
16 gauge vertical post
complete in all respect.

sqm

Rate (Rs)
Labour
Composite
4
5

95.00

20 - 24

3968.36

Specific
ation
6

Remark
7
panels
and of
2.45m
clear
height.
Analysis
for 4.0m x
2.75m
divided
into 9 Nos
equal size
panels
and of
2.45m
clear
height.

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

SECTION - 21

ELECTRIFICATION
1.

Rates for all finished works shall include the removal of surplus debris, unused
material and by products.

2.

The composite rates shall constitute compensation for the completed items of works
as per drawings, specifications and instructions of Engineer Incharge including all
labour and material/equipment required for the finished works.

A-I. Internal Electrification of Building


Sr.
No.
1

Description

Unit

Rate (Rs)

Specification
5

Remark
6

1 - POINT WIRING
A)

Wiring with 1/1.13 (3/0.29) PVC


insulated wire on surface steel
conduit 16 SWG (1.62 mm)
including bends inspection/switch
box/check Nut where necessary.

Wiring light or fan point with 1/1.13


mm (3/0.029) PVC insulated wire in
19.1 mm dia 16 SWG (1.62 mm)
thick steel conduit on surface
complete with switch, holder/ceiling
rose and plastic plate for switch,
regulator/dimmer upto 10 metre.

per
point

1662.48

21.3

Wire two ways light point with


1/1.13 mm (3/0.029) PVC insulated
wire in 19.1 mm 16 S.W.G (1.62
mm) conduit on surface complete
as per item No.5.

per
point

2648.31

-do-

Wire multiple light point for


controlling 2 lighting out let with
switch, with 1.13 mm (3/.029) PVC
insulated wire in M.S. Conduit 19.1
mm dia
16 SWG (1.62 mm)
including bends, inspection, box
switch & ceiling rose/batten holder
etc.

per
point

4570.11

-do-

As above but 3 lighting outlet will be


controlled with one switch.

per
point

3727.11

-do-

As above but 4 Nos. lighting outlet


will be controlled with one switch.

per
point

4530.94

-do-

As above but 5 Nos. lighting outlet


will be controlled with one switch.

per
point

5406.48

-do-

As above but 6 Nos. lighting outlet


will be controlled with one switch.

per
point

6499.29

-do-

WAPDA

21 - 1

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
8

Description

Unit

Rate (Rs)

2
Wiring 3/5 pin 5 Amps. Wall socket
point with 1/1.13 (3/.029) PVC
insulated conductor and 2.5 mm
PVC insulated earthing wire in M.S.
Conduit 19.1 mm dia 16 S.W.G.
(1.62 mm) on surface complete with
switch
socket
combined
(concealed).

3
per
point

4
1930.62

Specification
5
21.3

Wiring 2 pin plug control point with


1/1.13 (3/.029) PVC insulated wire
on switch board including plug &
switch.

per
point

184.07

-do-

10

Wiring call bell with 1/1.13 mm


(3/.029) PVC insulated wire in 19.1
mm 16 SWG (1.62 mm) gauge
steel conduit on surface complete
with Buzzer Bell push & 3 Metre
flexible wire 23/.0076 twin.

per
point

2239.22

-do-

B)

Wiring with 1/1.13 (3/0.29) PVC


insulated wire in recessed steel
conduit
including
bends
inspection/switch boxes/check nut
where necessary.

11

Wiring light or fan point with 1/1.13


mm (3/0.029) PVC insulated wire in
19.1 mm 16 SWG (1.62 mm) gauge
steel conduit recessed in the wall or
column complete with switch,
ceiling rose/batten holder in all
respects.

per
point

1732.18

-do-

12

Wire two ways light point with


1/1.13 mm (3/0.029) PVC insulated
wire in 19.1 mm heavy gauge steel
conduit recessed the wall or column
complete in all respects.

per
point

2365.62

-do-

13

Wire multiple light point for


controlling two lighting outlet with
one switch, with 1.13 mm (3/.029)
PVC insulated wire in 19.1 mm dia
16 SWG (1.62 mm) thick M.S.
Conduit included Bends, inspection
boxes, check nut, C.I./M.S. Box for
switch and switchers, ceiling
rose/batton holder complete in all
respects.

per
point

2591.54

-do-

14

As above but 3 lighting outlet will be


controlled with one switch.

per
point

3469.71

-do-

WAPDA

Remark

21 - 2

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
15

Description

Unit

Rate (Rs)

2
As above but 4 Nos. lighting outlet
will be controlled with one switch.

3
per
point

4
4130.32

Specification
5
21.3

16

As above but 5 Nos. lighting outlet


will be controlled with one switch.

per
point

4619.00

-do-

17

As above but 6 Nos. lighting outlet


will be controlled with one switch.

per
point

5717.84

-do-

18

Wiring 2 pin plug point on board


with 1/1.13 (3/0.29) PVC insulated
wire complete with switch and plug.

per
point

184.07

-do-

19

Wiring 3/5 pin 5 Amps. Wall socket


point with 1/1.13 (3.029) PVC
insulated wire and 2.5 mm PVC
insulated earthing conductor in M.S.
Conduit 18.1 mm dia M.S. Conduit
recessed in wall column complete
with switch socket combined.

per
point

2015.69

-do-

20

Wiring call bell with 1/1.13 mm


(3.029) PVC insulated wire in
19.1 mm heavy gauge steel conduit
recessed in the wall or column
complete with Buzzer, Push batten
& 3 Metre flexible wire 23/.0076
twin.

per
point

1921.12

-do-

C)

Wiring with 1/1.13 (3.029) PVC


insulated wire in PVC Conduit 1.50
mm thick 19.1 mm dia on surface
including bends, inspection switch
box where necessary.

21

Wiring light or fan point with 1/1.13


mm (3/0.029) PVC insulated wire in
19.1 mm PVC Conduit 1.50 mm
thick on surface complete with
switch, ceiling rose/batten holder in
etc.

per
point

1248.27

-do-

22

Wire two ways light point with


1/1.13 mm (3/0.029) PVC insulated
wire in 19.1mm PVC conduit 1.50
mm thick on surface complete with
switch, ceiling rose/batten holder
etc.

per
point

1841.51

-do-

23

Wiring 2 pin plug point on board


with 1/1.13 (3/0.29) PVC insulated
wire complete with switch and plug.

per
point

184.07

-do-

24

Wiring 3/5 pin 5 Amps. Wall socket


point with 1/1.13(3/.029) PVC
insulated wire and 2.5mm PVC

per
point

1274.66

-do-

WAPDA

Remark

21 - 3

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

25

D)

Specification
5

Description

Unit

Rate (Rs)

2
conduit 19.1mm 1.50 mm thick
fixed on surface complete with
switch socket etc.

Wiring call bell with 1/1.13 (3/0.029)


PVC insulated Wire in 19.1 mm
PVC conduit fitted on surface
complete with Buzzer, push & 3
Metre flexible wire 23/.0076 Twin

per
point

1472.10

21.3

Wiring with 1/1.13 (3/0.029) PVC


insulated wire in PVC Conduit
19.1 mm dia 1.50 thick recessed
including bends, inspection/switch
boxes where necessary etc.

26

Wiring light or fan point with 1/1.13


(3.029) PVC insulated wire in
19.1 mm , 1.50 mm thick PVC
conduit recessed in the wall or
column complete with switch plastic
plate ceiling rose/batten holder.

per
point

1315.67

-do-

27

Wiring two ways light point with


1/1.13 (3/0.029) PVC insulated wire
in 19.1mm , 1.50mm thick PVC
conduit recessed in the wall or
column complete with switch,
plastic plate, ceiling rose/batten
holder.

per
point

1727.12

-do-

28

Wiring 2 pin plug control point on


board with 1.13 (3/.029) PVC
insulated wire in 19.1 mm 1.50 mm
thick PVC conduit recessed in the
wall etc complete with switch and
plug.

per
point

184.07

-do-

29

Wiring multiple light point for


controlling two lighting outlet with
one switch with 1.13 mm (3/.029)
PVC insulated wire in PVC Pipe
19.1 mm dia
1.50 mm thick
complete with switch, ceiling
rose/batten holder etc.

per
point

1642.02

-do-

30

As above but 3 lighting outlet will be


controlled with one switch.

per
point

2191.34

-do-

31

As above but 4 lighting outlet will be


controlled with one switch.

per
point

2464.77

-do-

32

As above but 5 lighting outlet will be


controlled with one switch.

per
point

3003.44

-do-

As above but 6 lighting outlet will be


per
controlled with one switch.
point
WAPDA
21 - 4

3288.74

-do-

33

Remark

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
34

Specification
5

Description

Unit

Rate (Rs)

Wiring 3/5 pin 5 Amps. Wall socket


point with 1.13 mm PVC insulated
wire and 2.5 mm PVC insulated
earthing conductor in 19.1 mm
PVC Pipe recessed in wall/column
complete with switch socket etc.

per
point

1241.74

21.3

Remark
6

2- MISCELLANEOUS
A)

Wiring with 1/1.13 (3/.029) PVC


insulated wire in G.I.Pipe on
surface including bends, inspection
boxes where necessary etc.

Wiring for light or fan point with


1/1.13 (3/.029) PVC insulated wire
in 15 mm G.I. Pipe laid on surface
in courtyard or open terraces
complete
with
switch
button
holder/ceiling rose.

per
point

1847.00

-do-

Wiring 3/5 pin 5 Amps. Wall socket


paint with 1/1.13 mm (3/.029) PVC
insulated wire in G.I. Pipe 15 mm
dia fixed on surface including all
accessories and complete with
switch socket 3 pin 5 Amps.
Combined (concealed) and duly
earthed with 2.5 mm PVC insulated
earthing conductor.

per
point

2046.04

-do-

3 - MAINS AND SUB-MAINS


A)

With 2 wires in steel conduit 16


SWG (1.62 mm) thick including all
accessories.

Wiring mains with 2-1/1.13 (3/.029)


PVC insulated wire in 19.1 mm 16
SWG (1.62 mm) thick steel conduit
fitted
on
surface
including
accessories.

170.06

-do-

Wiring main with 2-1/1.38 (3/.036)


PVC insulated wire in 19.1 mm 16
SWG (1.62 mm) thick steel conduit
fitted
on
surface
including
accessories.

179.93

-do-

Wiring main with 2-1/1.78 (7/.029)


PVC insulated wire in 19.1 mm 16
SWG (1.62 mm) thick steel conduit
fitted
on
surface
including
accessories.

202.81

-do-

WAPDA

21 - 5

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
4

Description

Unit

2
Wiring main with 2-1/7/0.85 (7/.036)
PVC insulated wire in 19.1 mm 16
SWG (1.62 mm) thick steel conduit
fitted
on
surface
including
accessories.

3
m

4
232.45

Specification
5
21.3

Wiring main with 2-1/7/1.04 (7/.044)


PVC insulated wire in 19.1 mm 16
SWG (1.62 mm) thick steel conduit
fitted
on
surface
including
accessories.

271.95

-do-

Wiring main with 2-1/7/1.35 (7/.052)


PVC insulated wire in 25.4 mm 16
SWG (1.62 mm) thick steel conduit
fitted
on
surface
including
accessories.

363.86

-do-

Wiring main with 2-1/7/1.70 (7/.064)


PVC insulated wire in 25.4 mm
16 SWG (1.62 mm) thick steel
conduit fitted on surface including
accessories.

452.92

-do-

Wiring main with 2-1/19(7/.044)


PVC insulated wire in 25.4 mm
16 SWG (1.62 mm) gauge steel
conduit fitted on surface including
accessories.

571.42

-do-

Wiring main with 2-1/7/2.14)


(19.052) PVC insulated wire in 38.2
mm heavy gauge steel conduit
fitted
on
surface
including
accessories.

405.32

-do-

10

Wiring main with 2-1/19/1.53)


(19.064) PVC insulated wire in 38.2
mm heavy gauge steel conduit
fitted
on
surface
including
accessories.

552.93

-do-

B)

Rate (Rs)

With 2 wires in steel conduit 16


SWG (1.62 mm) recessed including
all accessories.

11

Wiring mains with 2-1/1.13(3.029)


PVC insulated wire in 19.1 mm
heavy
gauge
steel
conduit
recessed in wall as required.

158.35

-do-

12

Wiring mains with 2-1/1.38(3.036)


PVC insulated wire in 19.1 mm
16 SWG (1.62 mm) gauge steel
conduit recessed in wall as required
including all accessories.

168.22

-do-

WAPDA

Remark

21 - 6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
13

Description

Unit

2
Wiring mains with 2-1/1.78(7.029)
PVC insulated wire in 19.1 mm
16 SWG (1.62 mm) gauge steel
conduit recessed in wall as required
including all accessories.

3
m

4
183.03

Specification
5
21.3

14

Wiring mains with 2-1/7/0.85(7.036)


PVC insulated wire in 19.1 mm
16 SWG (1.62 mm) steel conduit
recessed in wall as required
including all accessories.

227.46

-do-

15

Wiring mains with 2-1/7/1.35(7.044)


PVC insulated wire in 19.1 mm
16 SWG (1.62 mm) steel conduit
recessed in wall as required
including all accessories.

252.15

-do-

16

Wiring mains with 2-1/7/1.35(7.052)


PVC insulated wire in 25.4 mm
16 SWG (1.62 mm) steel conduit
recessed in wall as required
including all accessories.

285.33

-do-

17

Wiring mains with 2-1/7/1.70(7.064)


PVC insulated wire in 25.4 mm
16 SWG (1.62 mm) steel conduit
recessed in wall as required
including all accessories.

437.15

-do-

18

Wiring mains with 2-1/19/.044 PVC


insulated wire in 25.4 mm 16 SWG
(1.62 mm) steel conduit recessed in
wall as well as required.

555.65

-do-

19

Wiring mains with 2-1/7/2.14


(19.052) PVC insulated wire in
38.2 mm
16 SWG (1.62 mm)
gauge steel conduit recessed in
wall as required.

531.05

-do-

20

Wiring mains with 2-1/19/1.53


(19.064) PVC insulated wire in
38.2 mm 16 SWG (1.62 mm) steel
conduit recessed in wall as required
including all accessories.

631.92

-do-

179.96

-do-

C)
21

WAPDA

Rate (Rs)

Remark
6

With 3 wire in steel conduit on


surface including all accessories.
Wiring mains with 3-1/1.13(3/.029)
PVC insulated wire 660 volts grade
in 19.1 mm 16 SWG (1.62 mm)
gauge steel conduit on surface as
required including all accessories.
21 - 7

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
22

Description

Unit

2
Wiring mains with 3-1/1.38(3/.036)
PVC insulated wire 660 volts grade
in 19.1 mm 16 SWG (1.62 mm)
gauge steel conduit on surface as
required including all accessories.

3
m

4
197.36

Specification
5
21.3

23

Wiring mains with 3-1/1.78(7/.029)


PVC insulated wire 660 volts grade
in 19.1 mm
16 SWG
(1.62
mm) gauge steel conduit on surface
as
required
including
all
accessories.

203.90

-do-

24

Wiring mains with 3-1/7/0.85


(7/.036) PVC insulated wire 660
volts grade in 19.1 mm 16 SWG
(1.62 mm) heavy gauge steel
conduit on surface as required
including all accessories.

236.54

-do-

25

Wiring mains with 3-1/7/1.04


(7/.044) PVC insulated wire 660
volts grade in 25.4 mm 16 SWG
(1.62 mm) steel conduit on surface
as
required
including
all
accessories.

302.61

-do-

26

Wiring mains with 3-1/7/1.35


(7/.052) PVC insulated wire 660
volts grade in 25.4 mm 16 SWG
(1.62 mm) steel conduit on surface
as
required
including
all
accessories.

376.44

-do-

27

Wiring mains with 3-1/7/1.70


(7/.064) PVC insulated wire 660
volts grade in 31.7 mm 16 SWG
(1.62 mm) gauge steel conduit on
surface as required including all
accessories.

576.81

-do-

28

Wiring mains with 3-1/19/0.044


PVC insulated wire 660 volts grade
in 31.7 mm 16 SWG (1.62 mm)
gauge steel conduit on surface as
required including all accessories.

618.16

-do-

29

Wiring mains with 3-1/7/2.14


(19/.052) PVC insulated wire 660
volts grade in 38.2 mm 16 SWG
(1.62 mm) gauge steel conduit on
surface as required including all
accessories.

712.05

-do-

30

Wiring mains with 3-1/19/1.53


(19/.064) PVC insulated wire 660
volts grade in 38.2 mm 16 SWG
(1.62 mm) gauge steel conduit

861.66

-do-

WAPDA

21 - 8

Rate (Rs)

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

31

D)

Specification
5

Description

Unit

Rate (Rs)

2
on surface as required including all
accessories.

Wiring mains with 3-1/19/2.14


(19/.083) PVC insulated wire 660
volts grade in 50.8 mm 16 SWG
(1.62 mm) gauge steel conduit on
surface as required including all
acce4ssories.

1171.80

21.3

With 3 wires in steel conduit


recessed including all accessories.

32

Wiring mains with 3-1/1.13(3/.029)


PVC insulated wire 660 volts grade
in 19.1 mm 16 SWG (1.62 mm)
steel conduit recessed in the wall
as
required
including
all
accessories.

166.95

-do-

33

Wiring mains with 3-1/1.38(3/.036)


PVC insulated wire 660 volts grade
in 19.1 mm 16 SWG (1.62 mm)
steel conduit recessed in the wall
as required.

184.44

-do-

34

Wiring mains with 3-1/1.78(7/.029)


PVC insulated wire 660 volts grade
in 19.1 mm 16 SWG (1.62 mm)
gauge steel conduit recessed in the
wall as required including all
accessories.

207.74

-do-

35

Wiring mains with 3-1/7/0.58


(7/.036) PVC insulated wire 660
volts grade in 19.1 mm 16 SWG
gauge steel conduit recessed in the
wall as required including all
accessories.

257.14

-do-

36

Wiring mains with 3-1/7/1.04


(7/.044) PVC insulated wire 660
volts grade in 25.4 mm 16 SWG
gauge steel conduit recessed in the
wall as required including all
accessories.

281.42

-do-

37

Wiring mains with 3-1/7/1.35


(7/.052) PVC insulated wire 660
volts grade in 25.4 mm 16 SWG
gauge steel conduit recessed in the
wall as required including all
accessories.

366.71

-do-

38

Wiring mains with 3-1/7/1.70


(7/.064) PVC insulated wire 660
volts grade in 31.7 mm 16 SWG

553.51

-do-

WAPDA

Remark

21 - 9

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Specification
5

Description

Unit

Rate (Rs)

2
gauge steel conduit recessed in the
wall as required including all
accessories.

39

Wiring mains with 3-1/19/.044


PVC insulated wire 660 volts grade
in 31.7 mm 16 SWG gauge steel
conduit recessed in the wall as
required including all accessories.

602.85

21.3

40

Wiring mains with 3-1/7/2.14


(19/.052) PVC insulated wire 660
volts grade in 31.7 mm 16 SWG
gauge steel conduit recessed in the
wall as required including all
accessories.

664.21

-do-

41

Wiring mains with 3-1/19/1.53


(19/.064) PVC insulated wire 660
volts grade in 38.2 mm 16 SWG
gauge steel conduit recessed in the
wall as required including all
accessories.

833.52

-do-

42

Wiring mains with 3-1/19/2.14


(19/.083) PVC insulated wire 660
volts grade in 50.8 mm 16 SWG
gauge steel conduit recessed in the
wall as required including all
accessories.

1136.14

-do-

E)

With 4 wire in steel conduit on


surface including all accessories.

43

Wiring mains with 4-1/1.13 (3/.029)


PVC insulated wire 660 volts grade
in 19.1 mm 16 SWG gauge steel
conduit on surface as required
including all accessories.

211.28.

-do-

44

Wiring mains with 4-1/1.38 (3/.036)


PVC insulated wire 660 volts grade
in 19.1 mm 16 SWG gauge steel
conduit on surface as required
including all accessories.

234.31

-do-

45

Wiring mains with 4-1/1.78 (7/.029)


PVC insulated wire 660 volts grade
in 25.4 mm 16 SWG gauge steel
conduit on surface as required
including all accessories.

248.40

-do-

Wiring mains with 4-1/7/0.85


m
(7/.036) PVC insulated wire 660
volts grade in 25.4 mm 16 SWG
gauge steel conduit on surface as
required including all accessories.
WAPDA
21 - 10

291.65

-do-

46

Remark

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
47

Description

Unit

2
Wiring mains with 4-1/7/1/04
(7/.044) PVC insulated wire 660
volts grade in 25.4 mm 16 SWG
gauge steel conduit on surface as
required including all accessories.

3
m

4
344.31

Specification
5
21.3

48

Wiring mains with 4-1/7/1/35


(7/.052) PVC insulated wire 660
volts grade in 31.7 mm 16 SWG
gauge steel conduit on surface as
required including all accessories.

525.87

-do-

49

Wiring mains with 4-1/7/1.70


(7/.064) PVC insulated wire 660
volts grade in 31.7 mm 16 SWG
gauge steel conduit on surface as
required including all accessories.

687.39

-do-

50

Wiring mains with 4-1/19/.044


PVC insulated wire 660 volts grade
in 31.7 mm 16 SWG gauge steel
conduit on surface as required
including all accessories.

745.12

-do-

51

Wiring mains with 4-1/7/2.14


(19/.052) PVC insulated wire 660
volts grade in 38.2 mm 16 SWG
gauge steel conduit on surface as
required including all accessories.

847.89

-do-

52

Wiring mains with 4-1/19/1.53


(19/.064) PVC insulated wire 660
volts grade in 50.8 mm 16 SWG
gauge steel conduit on surface as
required including all accessories.

1145.96

-do-

F)

Rate (Rs)

With 4 wires in steel conduit


recessed including all accessories.

53

Wiring mains with 4-1/1.13 (3/.029)


PVC insulated wire 660 volts grade
in 19.1 mm 16 SWG (1.62 mm)
gauge steel conduit recessed in the
wall as
required including all
accessories.

189.40

-do-

54

Wiring mains with 4-1/1.38 (3/.036)


PVC insulated wire 660 volts grade
in 19.1 mm16 SWG (1.62 mm)
gauge steel conduit recessed in the
wall as required including all
accessories.

280.55

-do-

55

Wiring mains with 4-1/1.78(7/.029)


PVC insulated wire 660 volts grade
in 25.4 mm 16 SWG gauge steel

225.55

-do-

WAPDA

Remark

21 - 11

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Specification
5

Description

Unit

Rate (Rs)

2
conduit recessed in wall as required
including all accessories.

56

Wiring mains with 4-1/7/0.85


(7/.036) PVC insulated wire 660
volts grade in 25.4 mm 16 SWG
gauge steel conduit recessed in
wall as required including all
accessories.

271.47

21.3

57

Wiring mains with 4-1/7/1.04


(7/.044) PVC insulated wire 660
volts grade in 25.4 mm 16 SWG
gauge steel conduit recessed as
required including all accessories.

321.47

-do-

58

Wiring mains with 4-1/7/1.35


(7/.052) PVC insulated wire 660
volts grade in 31.7 mm 16 SWG
gauge steel conduit recessed as
required including all accessories.

509.21

-do-

59

Wiring mains with 4-1/7/1.70


(7/.064) PVC insulated wire 660
volts grade in 31.7 mm 16 SWG
gauge steel conduit recessed as
required including all accessories.

666.73

-do-

60

Wiring mains with 4-1/19/1.04


(19/.044) PVC insulated wire 660
volts grade in 31.7 mm 16 SWG
gauge steel conduit recessed as
required including all accessories.

727.52

-do-

61

Wiring mains with 4-1/7/2.14


(19/.052) PVC insulated wire 660
volts grade in 38.2 mm 16 SWG
gauge steel conduit recessed as
required including all accessories.

818.13

-do-

62

Wiring mains with 4-19/1.53


(19.064) PVC insulated wire 660
volts grade in 50.8 mm 16
SWG gauge steel conduit on
surface as required including all
accessories.

1109.85

-do-

G)

With 3 Wires in G.I. Pipe on surface


including all accessories.

63

Wiring mains with 3-1/1.13 (3/.029)


PVC insulated wire 660 volts grade
in 19.1 mm G.I. Pipe on surface
including all accessories.

281.06

-do-

64

Wiring mains with 3-1/1.38 (3/.036)


PVC insulated wire 660 volts grade

297.59

-do-

WAPDA

Remark

21 - 12

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Specification
5

Description

Unit

Rate (Rs)

2
in 19.1 mm G.I. Pipe on surface
including all accessories.

65

Wiring mains with 3-1/1.78 (3/.029)


PVC insulated wire 660 volts grade
in 25 mm G.I. Pipe on surface
including all accessories.

370.63

21.3

66

Wiring mains with 3-1/7/0.85


(3/0.036) PVC insulated wire 660
volts grade in 25 mm G.I. Pipe on
surface including all accessories.

404.60

-do-

67

Wiring mains with 3-1/7/1.04


(7/0.044) PVC insulated wire 660
volts grade in 25 mm G.I. Pipe on
surface including all accessories

472.31

-do-

68

Wiring mains with 3-1/7/1.35


(7/0.052) 1-7/0.85(7/.056) PVC
insulated wire 660 volts grade in
31.7 mm G.I. Pipe on surface.

609.77

-do-

69

Wiring mains with 3-1/7/1.70


(7/.064) PVC insulated wire 660
volts grade in 31.7 mm G.I. Pipe on
surface.

728.95

-do-

70

Wiring mains with 3-1/19/.044


PVC insulated wire 660 volts grade
in 31.7 mm G.I. Pipe on surface.

772.02

-do-

71

Wiring mains with 3-1/7/2.14


(19/.052) PVC insulated wire 660
volts grade in 38.2 mm G.I. Pipe on
surface.

910.65

-do-

72

Wiring mains with 3-1/19/1.53


(19/.064) PVC insulated wire 660
volts grade in 38.2 mm G.I. Pipe on
surface.

1075.69

-do-

H)

With 4 wires in G.I. Pipe on surface


including all accessories.

73

Wiring mains with 4-1/1.13 (3.029)


PVC insulated wire 660 volts grade
in 19.1 mm G.I. Pipe on surface.

296.27

-do-

74

Wiring mains with 4-1/1.38 (3/.036)


PVC insulated wire 660 volts grade
in 19.1 mm G.I. Pipe on surface.

320.44

-do-

75

Wiring mains with 4-1/1.78 (7/.029)


PVC insulated wire 660 volts grade
in 25 mm G.I. Pipe on surface.

389.26

-do-

WAPDA

Remark

21 - 13

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
76

Description

Unit

2
Wiring mains with 4-1/7/0.85
(7/.036) PVC insulated wire 660
volts grade in 25 mm G.I. Pipe on
surface.

3
m

4
429.71

Specification
5
21.3

77

Wiring mains with 4-1/7/1.04


(7.044) PVC insulated wire 660
volts grade in 25 mm G.I. Pipe on
surface.

479.85

-do-

78

Wiring mains with 4-1/7/1.35


(7/.052) PVC insulated wire 660
volts grade in 31.7 mm G.I. Pipe on
surface.

670.74

-do-

79

Wiring mains with 4-1/7/1.70


(7/.064) PVC insulated wire 660
volts grade in 38.2 mm G.I. Pipe on
surface.

917.22

-do-

80

Wiring mains with 4-1/19/.0449


PVC insulated wire 660 volts grade
in 38.2 mm G.I. Pipe on surface.

976.64

-do-

81

Wiring mains with 4-1/7/2.14


(19/.052) PVC insulated wire 660
volts grade in 38.2 mm G.I. Pipe on
surface.

1040.60

-do-

82

Wiring mains with 4-1/19/1.53


(19/.064) PVC insulated wire 660
volts grade in 50 mm G.I. Pipe on
surface.

1885.68

-do-

I)

Rate (Rs)

With 2 wires in PVC Pipe on


surface including all accessories.

83

Wiring mains with 2-1/1.13 (3.029)


PVC insulated wire 660 volts grade
in 19.1 mm PVC conduit fitted on
surface.

83.31

-do-

84

Wiring mains with 2-1/1.38 (3/.036)


PVC insulated wire 660 volts grade
in 19.1 mm PVC conduit fitted on
surface.

102.69

-do-

85

Wiring mains with 2-1/1.78 (7/.029)


PVC insulated wire in 19.1 mm
PVC conduit fitted on surface.

110.09

-do-

86

Wiring mains with 2-1/7/0.85


(7/.036) PVC insulated wire 660
volts grade in 25 mm PVC conduit
fitted on surface.

147.54

-do-

WAPDA

Remark

21 - 14

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
87

Description

Unit

2
Wiring mains with 2-1/7/1.04
(7/.044) PVC insulated wire 660
volts grade in 25 mm PVC conduit
fitted on surface.

3
m

4
178.23

Specification
5
-do-

88

Wiring mains with 2-1/7/1.35


(7/.052) PVC insulated wire 660
volts grade in 25 mm PVC conduit
fitted on surface.

214.56

-do-

89

Wiring mains with 2-1/7/1.70


(7/.064) PVC insulated wire 660
volts grade in 31.7 mm PVC conduit
fitted on surface.

292.84

-do-

90

Wiring mains with 2-1/19//044


PVC insulated wire 660 volts grade
in 31.7 mm PVC conduit fitted on
surface.

327.43

-do-

91

Wiring mains with 2-1/7/2.14


(19/.052) PVC insulated wire 660
volts grade in 38.2 mm PVC conduit
fitted on surface.

396.70

-do-

92

Wiring mains with 2-1/19/1.53


(19/.064) PVC insulated wire 660
volts grade in 38.2 mm PVC conduit
fitted on surface.

497.42

-do-

J)

Rate (Rs)

With 2 wires in PVC Conduit


recessed including all accessories.

93

Wiring mains with 2-1/1.13 (3/.029)


PVC insulated wire in 19.1 mm
PVC Conduit recessed in the wall
as required.

85.87

-do-

94

Wiring mains with 2-1/1.38 (3/.036)


PVC insulated wire in 19.1 mm
PVC Conduit recessed in the wall
as required.

96.95

-do-

95

Wiring mains with 2-1/1.78(7/.029)


PVC insulated wire in 19.1 mm
PVC Conduit recessed in the wall
as required.

104.36

-do-

96

Wiring mains with 2-1/7/.085


(7/.036) PVC insulated wire in
25 mm PVC Conduit recessed in
the wall as required.

145.95

-do-

97

Wiring mains with 2-1/7/1.04


(7/.044) PVC insulated wire in
25 mm PVC Conduit recessed in
the wall as required.

176.61

-do-

WAPDA

Remark

21 - 15

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
98

Description

Unit

2
Wiring mains with 2-1/7/1.35
(7/.052) PVC insulated wire in
25 mm PVC Conduit recessed in
the wall as required.

3
m

4
212.90

Specification
5
21.3

99

Wiring mains with 2-1/7/1.70


(7/.064) PVC insulated wire in 31.7
mm PVC Conduit recessed in the
wall as required.

286.01

-do-

100

Wiring mains with 2-1/19/.044


PVC insulated wire in 31.7 mm
PVC Conduit recessed in the wall
as required.

322.54

-do-

101

Wiring mains with 2-1/7/2.14


(19/.052) PVC insulated wire in
31.7 mm PVC Conduit recessed in
the wall as required.

378.91

-do-

102

Wiring mains with 2-1/19/2.53


(19/.064) PVC insulated wire in
38.2 mm PVC Conduit recessed in
the wall as required.

447.92

-do-

K)

With 3 wires in PVC Conduit on


surface including all accessories.

103

Wiring mains with 3-1/1.13 (3/.029)


PVC insulated wire 660 volts grade
in 19.1 mm conduit on surface as
required.

104.69

-do-

104

Wiring mains with 3-1/1.38 (3/.036)


PVC insulated wire 660 volts grade
in 19.1 mm conduit on surface as
required.

117.19

-do-

105

Wiring mains with 3-1/1.78 (7/.029)


PVC insulated wire 660 volts grade
in 25 mm conduit on surface as
required.

140.91

-do-

106

Wiring mains with 3-1/7/0.85


(7/.036) PVC insulated wire 660
volts grade in 25 mm conduit on
surface as required.

173.63

-do-

107

Wiring mains with 3-1/7/1.04


(7/.044) PVC insulated wire in
25 mm PVC Conduit on surface on
the wall as required.

210.10

-do-

108

Wiring mains with 3-1/7/1.70


(7/.064) PVC insulated wire in
31.7 mm PVC Conduit on surface
on the wall as required.

295.38

-do-

WAPDA

21 - 16

Rate (Rs)

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
109

Description

Unit

2
Wiring mains with 3-1/7/1.70
(7/.064) PVC insulated wire in
31.7 mm PVC Conduit on surface
on the wall as required.

3
m

4
423.80

Specification
5
21.3

110

Wiring mains with 3-1/19/.044


PVC insulated wire in 31.7 mm
PVC Conduit on surface on the wall
as required.(fitted with G.I. Clamps)

453.33

-do-

111

Wiring mains with 3-1/7/2.14


(19/.052) PVC insulated wire in
38.2 mm PVC Conduit on surface
on the wall as required.(fitted with
G.I. Clamps)

531.85

-do-

112

Wiring mains with 3-1/19/1.53


(19/.064) PVC insulated wire in
38.2 mm PVC Conduit on surface
on the wall as required.(fitted with
G.I. Clamps)

675.73

-do-

L)

With 3 wires in PVC conduit


recessed including all accessories.

113

Wiring mains with 3-2/1.13(3/.029)


PVC insulated wire in 19.1 mm
PVC Conduit on surface on the wall
as required.

98.49

-do-

114

Wiring mains with 3-1/1.38(3/.036)


PVC insulated wire in 19.1 mm
PVC Conduit on surface on the wall
as required.

115.99

-do-

115

Wiring mains with 3-1/1.78(7/.029)


PVC insulated wire in 25 mm
PVC Conduit on surface on the wall
as required.

137.89

-do-

116

Wiring mains with 3-1/7/0.85


(7/.036) PVC insulated wire 660
volts grade in 25 mm PVC conduit
recessed in the wall as required.

170.59

-do-

117

Wiring mains with 3-1/7/1.04


(7/.044) PVC insulated wire 660
volts grade in 25 mm PVC conduit
recessed in the wall as required.

207.06

-do-

118

Wiring mains with 3-1/7/1.35


(7/.052) PVC insulated wire 660
volts grade in 25 mm PVC conduit
recessed in the wall as required.

291.45

-do-

WAPDA

21 - 17

Rate (Rs)

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
119

Description

Unit

2
Wiring mains with 3-1/7/1.70
(7/.064) PVC insulated wire 660
volts grade in 31.7 mm PVC conduit
recessed in the wall as required.

3
m

4
423.14

Specification
5
21.3

120

Wiring mains with 3-1/19/.044


PVC insulated wire 660 volts grade
in 31.7 mm PVC conduit recessed
in the wall as required.

512.63

-do-

121

Wiring mains with 3-1/7/2.14


(19/.052) PVC insulated wire 660
volts grade in 38.2 mm PVC conduit
recessed in the wall as required.

755.73

-do-

122

Wiring mains with 3-1/19/1.53


(19/.064) PVC insulated wire 660
volts grade In
38.2 mm PVC
conduit recessed in the wall as
required.

1081.58

-do-

M)

With 4 wires in PVC Conduit on


surface: including all accessories.

123

Wiring mains with 4-1/1.13 (3/.029)


PVC insulated wire 660 volts grade
in 20mm PVC conduit on surface.

146.56

-do-

124

Wiring mains with 4-1/1.38 (3/.036)


PVC insulated wire 660 volts grade
in 19.1 mm
PVC conduit on
surface.
Wiring mains with 4-1/1.78 (7/.029)
PVC insulated wire 660 volts grade
in 25 mm PVC conduit on surface.

165.84

-do-

188.52

-do-

126

Wiring mains with 4-1/7/0.85


(7/.036) PVC insulated wire 660
volts grade in 25 mm PVC conduit
on surface.

212.55

-do-

127

Wiring mains with 4-1/7/1.04


(7/.044) PVC insulated wire 660
volts grade in 25 mm PVC conduit
on surface.

304.12

-do-

128

Wiring mains with 4-1/7/1.35


(7/.052) PVC insulated wire 660
volts grade in 31.7 mm PVC conduit
on surface.

490.49

-do-

129

Wiring mains with 4-1/7/1.70


(7/.064) PVC insulated wire 660
volts grade in 31.7 mm PVC conduit
on surface.

683.27

-do-

125

WAPDA

21 - 18

Rate (Rs)

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
130

Description

Unit

2
Wiring mains with 4-1/19/.044
PVC insulated wire 660 volts grade
in 38.2 mm PVC conduit on
surface.

3
m

4
996.52

Specification
5
21.3

131

Wiring mains with 4-1/7/2.14


(19/.052) PVC insulated wire 660
volts grade in 38.2 mm PVC conduit
on surface.

901.76

-do-

N)

With 4 wires in PVC Conduit


recessed including all accessories.

132

Wiring mains with 4-1/1.13 (3/.029)


PVC insulated wire 660 volts grade
in 38.2 mm PVC conduit recessed.

136.85

-do-

133

Wiring mains with 3-1/1.38 (3/.036)


and 1-1/1.13(3/.029) PVC insulated
wire 660 volts grade in 19.1 mm
PVC Conduit recessed in the wall
as required.

156.12

-do-

134

Wiring mains with 4-1/1.78 (7/.029)


PVC insulated wire 660 volts grade
in 25 mm PVC conduit recessed in
the wall as required.

189.78

-do-

135

Wiring mains with 4-1/7/0.85


(7/.036) and 1-1/1.78 (7/.029) PVC
insulated wire 660 volts grade in 25
mm PVC Conduit recessed in the
wall as required.

218.39

-do-

136

Wiring mains with 4-1/7/1.04


(7/.044) PVC insulated wire 660
volts grade in 25 mm PVC Conduit
recessed in the wall as required.

647.42

-do-

137

Wiring mains with 4-1/7/1.35


(7/.052) PVC insulated wire 660
volts grade in 31.7 mm PVC
Conduit recessed in the wall as
required.

480.70

-do-

138

Wiring mains with 4-1/7/1.70


(7/.064) PVC insulated wire 660
volts grade in 31.7 mm PVC
Conduit recessed in wall as
required.

673.42

-do-

139

Wiring mains with (4-1/19/.044)


PVC insulated wire 660 volts grade
in 38.2 mm PVC Conduit recessed
in wall as required.

973.61

-do-

WAPDA

21 - 19

Rate (Rs)

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
140

Description

Unit

2
Wiring mains with 4-1/7/2.14
(19.052) PVC insulated wire 660
volts grade in 38.2 mm PVC
Conduit recessed in wall as
required.

3
m

4
1020.62

Specification
5
21.3

Rate (Rs)

O)

With 6 Wires in G.I.Pipe on surface


for Motor connection complete with
all accessories.

141

Wiring from starter to motor with


6-1/7/0.85 (7/.036) PVC Insulated
wires in G.I.Pipe 32 mm dia on
surface including all accessories.

647.42

-do-

142

Wiring from starter to motor with


6-1/7/1.04 (7/.044) PVC Insulated
wires in G.I.Pipe 32 mm dia on
surface including all accessories.

785.89

-do-

143

Wiring from starter to motor with


6-1/7/1.70 (7/.064) PVC Insulated
wires in G.I.Pipe 38.2 mm dia on
surface including all accessories.

1357.95

-do-

144

Wiring from starter to motor with


6-1/19/.044 PVC Insulated wires in
G.I.Pipe 50 mm dia on surface
including all accessories.

2172.73

-do-

145

Wiring from starter to motor with


6-1/7/2.14 (19/.052) PVC Insulated
wires in G.I.Pipe 50 mm dia on
surface including all accessories.

2245.62

-do-

146

Wiring from starter to motor with


6-1/19/1.53
(19/.064)
PVC
Insulated wires in G.I.Pipe 65 mm
dia on surface including all
accessories.

2921.53

-do-

147

Wiring from starter to motor with


6-1/19/2.14 (19/.083) PVC Cable
660 volts in G.I.Pipe 80 mm dia
fixed on surface including all
accessories.

3547.58

-do-

P)

PVC Cable Insulated /Sheathed


Four Core Cables.

148

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 19/.052(7/2.14
mm) on wooden cleats with angle
iron base size 38 mm x 3 mm 60
mm long.

1145.90

-do-

WAPDA

21 - 20

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
149

Description

Unit

2
Supply and erection of PVC
insulated PVC Sheathed 4 core
copper cable size 19/.064(19/1.53
mm) 4 core on wooden cleats with
angle iron base size 38 mm x 3 mm
60 mm long.

3
m

4
1731.49

Specification
5
21.3

150

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper
cable
size
19/.083(19/2.14 mm) 4 core on
wooden cleats with angle iron base
size 38 mm x 3 mm 60 mm long.

2843.87

-do-

151

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 19/.052(7/2.14
mm) in existing trench.

768.84

-do-

152

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 19/.064(19/1.53
mm) in existing trench.

1311.94

-do-

153

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 19/.083(19/2.14
mm) in existing trench.

2428.73

-do-

Q)

E.C.C.

154

Providing/laying and connecting


hard drawn bare copper wire 2.076
mm as earth continuity conductor
with any given main or sub-main in
all system of wiring.

10.28

-do-

155

Providing/laying and connecting


hard drawn bare copper wire 3.2
mm2 (14 S.W.G) as earth continuity
conductor with any given mains or
sub-main in all system of wiring.

13.80

-do-

156

Providing & fixing hard drawn bare


copper wire 5.4 mm2 (12 S.W.G) as
earth continuity conductor with any
given mains or sub-main in all
system of wiring.

22.91

-do-

157

Providing & fixing hard drawn bare


copper wire 8.7 mm2 (10 S.W.G) as
earth continuity conductor with any
given mains or sub-main in all
system of wiring including metallic
electrical accessories.

27.53

-do-

WAPDA

21 - 21

Rate (Rs)

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
158

Description

Unit

2
Providing & fixing hard drawn bare
copper wire 13 mm2 (8 S.W.G) as
earth continuity conductor with any
given mains or sub-main in all
system of wiring including metallic
electrical accessories.

3
m

4
32.81

Specification
5
21.3

159

Providing & fixing hard drawn bare


copper wire 19 mm2 (6 S.W.G) as
earth continuity conductor with any
given mains or sub-main in all
system of wiring including metallic
electrical accessories.

53.98

-do-

160

Providing & fixing hard drawn bare


copper wire 27 mm2 (4 S.W.G) as
earth continuity conductor with any
given mains or sub-main in all
system of wiring including metallic
electrical accessories.

54.86

-do-

161

Providing & fixing hard drawn bare


copper wire 32 mm2 (3 S.W.G) as
earth continuity conductor with any
given mains or sub-main in all
system of wiring including metallic
electrical accessories.

74.42

-do-

162

Providing & fixing hard drawn bare


copper wire 38.6 mm2 (2 S.W.G) as
earth continuity conductor with any
given mains or sub-main in all
system of wiring including metallic
electrical accessories.

89.42

-do-

163

Providing & fixing hard drawn bare


copper wire 45.6 mm2 (1 S.W.G) as
earthing conductor in earthing
pit/trench etc.

125.73

-do-

164

Providing & fixing hard drawn bare


copper tap 19.1 x 3 mm as earthing
conductor for laying in earthing
pit/trench etc.

174.22

-do-

165

Providing & fixing and connecting


hard drawn bare copper Tap
25.4 mm x 3 mm as earthing
conductor for laying in earthing
pit/trench etc.

230.49

-do-

166

Providing & fixing and connecting


hard drawn bare copper Tap 38.2
mm x 3 mm as earthing conductor
for laying in earthing pit/trench etc.

386.95

-do-

WAPDA

21 - 22

Rate (Rs)

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Description

Unit

Rate (Rs)

Specification
5

Remark
6

4 - ELECTRICAL ACCESSORIES
A)

Surface Type Switches

Providing & fixing and connecting


one way S.P. 5 Amps. Switch
already fixed board as replacement.

each

53.80

21.3

Providing & fixing and connecting


two ways S.P. 10/15 Amps. Switch
on already fixed a given prepared
board as replacement.

each

55.97

-do-

Providing & fixing and connecting


A.C. one way S.P. 10/15 Amps.
Switch on already fixed a given
prepared board.

each

73.10

-do-

B)

FLUSH TYPE SWITCHES

Providing & fixing/connecting A.C.


one way S.P. 5 Amps, switch flush
type (Piano type) as replacement
on open wooden board.

each

56.66

-do-

Providing & fixing /connecting A.C.


two ways S.P. 5 Amps, switch flush
type on a given prepared board as
replacement.

each

63.70

-do-

Providing & fixing/connecting A.C.


one way S.P. 5 Amps, already flush
type switch as replacement on
metal board recessed in the walls
or columns and covered with sheet.

each

69.27

-do-

Providing & fixing /connecting A.C.


one way S.P. 10/15 Amps, already
flush type switch as replacement on
metal board recessed in the walls
or columns and covered with sheet.

each

85.73

-do-

each

63.70

-do-

each

73.97

-do-

C)
8

D)
9

WAPDA

Flush Type Switches - Two ways


Providing & fixing /connecting A.C.
two ways S.P. 5 Amps, already
flush type switch on metal board
already recessed in the walls or
columns and covered with sheet as
replacement.
Weather Proof Switches
Providing and fixing/connecting
A.C. two ways S.P. 5 Amps 250
volts switch as replacement in
weather proof cast iron case
already fixed.

21 - 23

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
10

11.

E)

Description

Unit

Rate (Rs)

2
Providing and fixing A.C. one way 5
Amps 250 volts, switch in weather
proof cast iron case complete with
switch & C.I. Case.

3
each

4
265.42

Specification
5
21.3

Providing and fixing/connecting


A.C. one way 15 Amps. 250 volts
switch, weather proof cast iron case
with front operated disc handle on a
given board complete with C.I.
Case.

each

406.49

-do-

Providing and fixing/connecting


surface type 2 pin 5 Amps S.P.
Plug-socket as replacement on
already fixed wooden board.

each

51.42

-do-

13.

Providing and fixing/connecting


surface type 2 pin 5 Amps S.P.
Plug-socket, switch complete with
S.W. Board as replacement.

each

101.45

-do-

14.

Providing and fixing flush type 2 pin


5 Amps S.P. Plug-socket on
already fixed board.

each

50.08

-do-

15.

Providing and fixing/ connecting


flush type 2 pin 5 Amps S.P. Plugsocket on Metal Board recessed in
the wall or columns as replacement
with plastic sheet.

each

81.56

-do-

3-Pin, 5Amps. Plug Socket:

16.

Providing and fixing surface type 3


pin 5 Amps S.P. Plug-socket on a
given prepared board.

each

61.32

-do-

17.

Providing and fixing type 3 pin 5


Amps flush type S.P. Plug-socket
and switch complete with board.

each

241.53

-do-

18.

Providing and fixing type 3 pin 5


Amps flush type S.P. Plug-socket
and switch combined on board as
replacement.

each

73.94

-do-

19.

Providing and fixing flush type 3 pin


5 Amps S.P. Plug-socket, switch
combined fixed on M.S./C.I Box on
surface complete with C. I. Box.

each

168.30

-do-

WAPDA

2-Pin, 5Amps. Plug Socket:

12.

F)

Remark

21 - 24

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
G)

Description

Unit

Rate (Rs)

2
3 Pin, 15 Amps Plug Socket:

Specification
5

20.

Providing and fixing surface type 2


pin 15 Amps S.P. Plug-socket and
switch as replacement on board
already exit.

each

108.35

21.3

21

Providing and fixing surface type 3


pin 15 Amps S.P. Plug-socket and
switch as replacement complete
with board.

each

291.00

-do-

22

Providing and fixing flush type 3 pin


15 Amps S.P. Plug-socket, switch
(combined) as replacement on
board already exist.

each

174.43

-do-

23

Providing and fixing flush type 3 pin


15 Amps S.P. Plug-socket, switch
(combined) as replacement on
board already exist.

each

255.04

-do-

H)

Providing and fixing S.P. 5 Amps 3


pin plug-socket and switch as
replacement in switch weather
proof type cast iron case already
exist.

each

147.90

-do-

25

Providing and fixing S.P. 15 Amps 3


pin plug-socket and switch as
replacement in switch weather
proof type cast iron case already
exist.

each

191.61

-do-

26

Providing and fixing S.P. 5 Amps 3


pin plug-socket and switch in
weather proof type both in one cast
iron case complete with case.

each

412.57

-do-

27

Providing and fixing S.P. 5 Amps 3


pin plug-socket and switch in
weather proof type both in one cast
iron case complete with case.

each

615.21

-do-

Electric Bells:

28

Providing and fixing A.C. or D.C.


electric bell 200/250 volts 70 mm
Gong as replacement.

each

130.19

-do-

29

Providing and fixing A.C. or D.C.


electric Buzzer 200/250 volts as
replacement

each

79.71

-do-

WAPDA

Weather Proof Plug Socket:

24

I)

Remark

21 - 25

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
30

J)

Description

Unit

Rate (Rs)

2
Providing and fixing A.C. weather
proof iron case electric bell 200/250
volts 100 mm Gong.

3
each

4
719.10

Specification
5
21.3

Providing and fixing connecting


flush type electric bell push button
as replacement on a prepared
board.

each

55.47

-do-

32

Providing and fixing bakelite table


push with 2.74 m twin core circular
P.V.C. flexible cord as replacement.

each

126.90

-do-

33

Providing and fixing multiple piano


type table bell push 2 ways to be
fixed with table P.V.C. flexible cord
as replacement.

each

81.08

-do-

Electric Bell Indicator:

34

Providing and fixing electric bell


indicator 2 ways with manual
repulse operation in wooden box.

each

770.54

-do-

35

Providing and fixing electric bell


indicator 4 ways with manual
repulse operation in wooden box.

each

1154.00

-do-

36

Providing and fixing electric bell


indicator 6 ways with manual
repulse operation in wooden box.

each

1934.79

-do-

37

Providing and fixing electric bell


indicator 8 ways with manual
repulse operation in wooden box.

each

1588.96

-do-

38

Providing and fixing electric bell


indicator 12 ways with manual
repulse operation in wooden box.

each

3838.21

-do-

sqm

4563.03

-do-

Providing and fixing hinged type


sqm
double D.W.Board to accommodate
mains
or
sub-mains
control
switches and for other similar jobs
on surface.
WAPDA
21 - 26

6712.43

-do-

A)
1

Electric Bell Push:

31

K)

Remark

Board:

5 - BOARDS

Providing
and
fixing
double
D.W.Board to accommodate mains
or submain control switches and for
other similar jobs on surface 50 mm
deep with upper & bottom planks
13 mm thick

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
3

Description

Unit

Rate (Rs)

2
Providing and fixing metal board to
accommodate mains or sub-mains
control switches and for other
similar jobs on surface.

3
sqm

4
13134.44

Specification
5
21.3

Providing and fixing metal board to


accommodate mains or sub-mains
control switches recessed in the
wall,
required
including
all
accessories.

sqm

11568.64

-do-

Providing and fixing floor mounting


metal board 1.20 metre high from
bottom (size of angle iron 50 x 50 x
6 mm sheet 8 SWG (4.064 mm ) to
accommodate mains or sub-mains
control switches and for other
similar jobs total high from floor in
2.20 metre

sqm

10832.44

-do-

Remark
6

6 - FITTINGS & FIXTURES


A)

Pendent Light Fittings:

Providing and fixing bakelite


pendent consisting of 1.22 m twin
core
circular
24/0.19.1
mm
(23/0.0076) PVC Insulated PVC
sheathed flexible cord with bakelite
lamps holder and 254 mm white
plastic shade.

each

138.04

-do-

Providing and fixing bakelite


pendent consisting of 1.22 m twin
core
circular
24/0.20
mm
(23/0.0076) PVC Insulated PVC
sheathed flexible cord with bakelite
lamps holder and 254 mm E.I.
Shade.

each

178.01

-do-

Providing and fixing Plain Pendent


consisting of 1.22 m twin core
circular 24/0.24 mm (23/0.0076)
PVC Insulated PVC sheathed
flexible cord with bakelite lamps
holder and 254 mm white plastic
shade.

each

156.84

-do-

Providing and fixing bakelite


pendent consisting of 1.22 m twin
core
circular
16/0.19.1
mm(23/0.0076) PVC Insulated PVC
sheathed flexible cord with bakelite
lamps holder and 254 mm E.I.
Shade.

each

196.81

-do-

WAPDA

21 - 27

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
B)

Description
2
Bracket Light Fittings:

Unit

Rate (Rs)

Specification
5

Providing and fixing brass bracket


229 mm size fitted with brass lamp
holder and 254 mm EI shade.

each

271.28

21.3

Providing and fixing brass bracket


229 mm size fitted with brass lamp
holder and 254 mm white plastic
shade.

each

231.31

-do-

Providing and fixing brass bracket


229 mm size fitted with brass lamp
holder and 254 mm EI shade.

each

252.47

-do-

Providing and fixing brass bracket


229 mm size fitted with brass lamp
holder and 254 mm Plastic Shade.

each

212.42

-do-

C)

Batten Light Fittings:

Providing and fixing B.C. bakelite


batten lamp holder with 254 mm EI
Shade

each

119.17

-do-

10

Providing and fixing B.C. bakelite


batten lamp holder with 254 mm
white plastic shade

each

78.99

-do-

11

Providing and fixing B.C. brass


batten lamp holder with 254 mm EI
Shade

each

130.94

-do-

12

Providing and fixing B.C. brass


batten lamp holder with 254 mm
White Plastic shade.

each

90.98

-do-

13

Providing and fixing B.C. brass


Angular Type Holder batten holder.

each

67.84

-do-

14

Providing and fixing B.C. brass


centre swivelling type batten holder.

each

94.25

-do-

15

Providing and fixing B.C. batten


lamp holder with 150 mm white opal
glass globe and gallery etc.
Providing and fixing B.C. bakelite
batten lamp holder with 200 mm
white glass globe and gallery etc.

each

195.29

-do-

each

237.58

-do-

Fixing
A.C.
Ceiling
fan
each
regulator/dimmer on S.W. board on
surface as replacement.
WAPDA
21 - 28

216.74

-do-

16

Remark

7 - FANS
A)
1

Ceiling Fan Regulators/Dimmer:

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
2

B)

Description

Unit

Rate (Rs)

2
Fixing
A.C.
Ceiling
fan
regulator/dimmer on metal board
recessed in the walls/columns and
covered with sheet.

3
each

4
254.61

Specification
5
21.3

Providing and fixing mild steel bar


fan clamp 13 mm dia suitable for
R.C.roof.

each

155.40

-do-

Providing and fixing for wooden


beam Mild steel flat 6 mm x
100 mm size frame box type having
double bolts and double nuts on
each side and with a suspension
M.S. round 13 mm dia clamp as
required.

each

450.24

-do-

Providing and fixing R.C.C. beam


Mild steel flat 100 mm x 6mm size
framed with suspension of mild
steel round 13 mm dia clamp tied
up with bolt and double nuts
through the beam to hold the
suspension clamp as required.

each

450.24

-do-

Providing and fixing girder type fan


clamp of mild steel flat 50 mm x
6 mm size with suspension of M.S.
Round 12.7 mm dia clamp tied up
with double nuts and bolts on both
sides as required.

each

276.27

-do-

Providing and fixing G.I.Pipe type


fan clamp of mild steel flat 50 mm x
6 mm size with suspension of M.S.
Round 12.7 mm dia clamp tied up
with double bolts and nuts on both
sides.

each

309.26

-do-

Providing and fixing G.I. Pipe


50 mm dia size suspension for fan
clamps as required.

399.30

-do-

Providing and fixing G.I. Pipe


38.2 mm size suspension for fan

425.63

-do-

10

Providing and fixing G.I. Pipe


32 mm size suspension for fan
clamps as required.

359.86

-do-

11
WAPDA

Fan Clamps:

C)

Remark

S/Erection of Fans
Supply and erection of ceiling fan
best quality including wiring of
21 - 29

-doWCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Description

Unit

Rate (Rs)

2
down rod with 1/1.13 mm (3/.029)
PVC wire, fixing of regulator, blade,
canopy etc
a) 915 mm (36) sweep
b) 1219 mm (48) sweep
c) 1422 mm (56) sweep

each
each
each

3316.77
3669.55
3787.10

Specification
5

12

Supply and erection of 457 mm


(18) sweep bracket fan including
wiring with 1/1.13 mm (3/.029) PVC
wire, fixing of blade etc. as
required.

each

2957.56

-do-

13

Erection of bracket fan including its


connection.

each

121.09

-do-

14

Erection of exhaust fans of all sizes


in the opening already exist.

each

121.09

-do-

D)

Remark
6

Butterfly Shutters:

15

Providing and erection butterfly


shutters for 229 mm sweep exhaust
fan complete as required.

each

133.38

-do-

16

Providing and erection butterfly


shutters for 305 mm sweep exhaust
fan complete as required.

each

155.73

-do-

17

Providing and erection butterfly


shutters for 380 mm sweep exhaust
fan complete as required.

each

166.31

-do-

18

Providing and erection butterfly


shutters for 457 mm sweep exhaust
fan complete as required.

each

183.94

-do-

Providing and fixing of distribution


each
board single phase 30 Amps, 250
volts with 1-No. incoming circuit
WAPDA
21 - 30

7154.41

-do-

8 - SWITCH GEARS
A)

Circuit Breaker
Providing and fixing distribution
board comprising incoming and
outgoing circuit breaker, neutral link
and auxiliary wiring completely
housed in M.S. Box of 1.62 mm
thick sheet having detachable inner
cover and outer hinged type
lockable door, duly painted inside
and
outside
with
Deco
spray/powdered paint.

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Specification
5

Description

Unit

Rate (Rs)

2
breaker 30 Amps. D.P. 4-Nos. outgoing 6-15 Amps. Single pole circuit
breaker with N link on prepared
board.

Providing and fixing of distribution


board single phase 60 Amps, 250
volts with 1-No. incoming circuit
breaker 60 Amps. D.P. 4-Nos. outgoing 6-15 Amps. Single pole circuit
breaker with N link on prepared
board.

each

7700.11

21.3

Providing and fixing of distribution


board single phase 60 Amps, 250
volts with 1-No. incoming circuit
breaker 60 Amps. D.P. 6-Nos. outgoing 6-15 Amps. Single pole circuit
breaker with N link on prepared
board.

each

9612.25

-do-

Providing and fixing of distribution


board three phase 400 volts 3 ways
with 1-No. incoming circuit breaker
30 Amps. 400 volts and 3 circuit
breaker 6-15 Amps. S.P. in each
phase on prepared board.

each

15501.50

-do-

Providing and fixing of distribution


board three phase 60-Amps. 400
volts 4 ways per phase with 1-No.
incoming circuit breaker 60 Amps.
400 volts O/Gang circuit breaker
S.P. 6-15 Amps. on prepared
board.

each

20740.61

-do-

Providing and fixing of distribution


board three phase 60-Amps. 400
volts 6 ways per phase with 1-No.
incoming circuit breaker 60 Amps.
400 volts O/Gang circuit breaker
S.P. 6-15 Amps. on prepared
board.

each

24752.23

-do-

Providing and fixing of distribution


board three phase 60-Amps. 400
volts 6 ways per phase with 1-No.
incoming circuit breaker 60 Amps.
400 volts O/Gang circuit breaker
S.P. 6-30 Amps. complete with volt
metre and indication light on each
phase on prepared board.

each

27695.36

-do-

Providing and fixing of distribution


each
board single phase 100 Amps, 400
volts 6-ways per phase with 1-No.
incoming circuit breaker 100 Amps.
WAPDA
21 - 31

29436.34

-do-

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Specification
5

Description

Unit

Rate (Rs)

2
400 volts & outgoing breaker S.P.
6.30 Amps. complete with volt
metre, selector switch, & phase
indication lights and N link on a
given board.

Providing and fixing of distribution


board three phase 100 Amps, 400
volts 8-ways per phase with 1-No.
incoming circuit breaker 100 Amps.
400 volts & outgoing breaker S.P.
6.30 Amps. Complete with volt
metre, selector switch, & phase
indication lights and N link on a
given board.

each

34222.05

21.3

10

Providing and fixing of distribution


board three phase 100 Amps, 400
volts 10-ways per phase with 1-No.
incoming circuit breaker 100 Amps.
400 volts & outgoing breaker S.P.
6.30 Amps. Complete with volt
metre, selector switch, & phase
indication lights and N link on a
given board.

each

39314.57

-do-

11

Providing and fixing of distribution


board three phase 150/200-Amps,
400 volts
10-ways per phase
with 1-No. incoming circuit breaker
100 Amps. 400 volts & outgoing
breaker S.P. 6.30 Amps. Complete
with volt metre, selector switch, &
phase indication lights and N link
on a given board.

each

52490.24

-do-

12

Providing and fixing of distribution


board three phase 150/200-Amps,
400 volts
12-ways per phase
with 1-No. incoming circuit breaker
100 Amps. 400 volts & outgoing
breaker S.P. 6.30 Amps. Complete
with volt metre, selector switch, &
phase indication lights and N link
on a given board.

each

58008.29

-do-

13

Providing and fixing of distribution


board three phase 200 Amps. 250
volts 14 ways per phase with I/C
breaker 6-30 Amps and N link volt
metre ampare metre selector
switches, C.T's. indication light on
each phase on surface board.

each

67544.42

-do-

Providing and fixing of distribution


each
board single phase 30/60 Amps,
250 volts 4-ways per phase with
WAPDA
21 - 32

7489.08

-do-

14

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Specification
5

Description

Unit

Rate (Rs)

2
One No. circuit breaker 30/60
Amps. D.P.& 4-Nos. outgoing circuit
breakers 6.30 Amps. & N link fixed
in M.S. Box of suitable size
recessed in wall.

15

Providing and fixing of distribution


board single phase 30/60 Amps,
250 volts
6-ways per phase
with One No. circuit breaker 30/60
Amps. D.P.& 4-Nos. outgoing circuit
breakers 6.30 Amps. &
N link
fixed in M.S. Box of suitable size
recessed in wall.

each

8873.17

21.3

16

Providing and fixing of distribution


board single phase 60 Amps, 8ways per phase 250 volts with One
I/Comming circuit breaker 60 Amps.
D.P. & Circuit Breakers 6.30 S.P. in
m.s. box of suitable size.

each

10878.92

-do-

17

Providing and fixing of distribution


board three phase 60 Amps, 400
volts 3-ways per phase with One
I/C circuit breaker 30 Amps. T.P.
and outgoing breakers 6-30 Amps.
complete with N link in wall
recessed.

each

15013.75

-do-

18

Providing and fixing of distribution


board single phase 60 Amps, 400
volts 4-ways per phase with One
I/C circuit breaker 60 Amps.
complete with N link in wall
recessed.

each

20977.58

-do-

19

Providing and fixing of distribution


board three phase 60 Amps, 400
volts 6-ways per phase with One
I/C circuit breaker 60 Amps. T.P.
and outgoing breaker 6-30 Amps.
complete with N link in wall
recessed.

each

27950.07

-do-

20

Providing and fixing of distribution


board three phase 100 Amps, 400
volts 6-ways per phase with One
I/C circuit breaker 100 Amps. T.P.
and outgoing breaker 6-30 Amps.
S.P. Complete with volt metre
selector switch, phase indication
light & N link etc. recessed in wall.

each

29729.87

-do-

Providing and fixing of distribution


each
board three phase 100 Amps, 400
volts 8-ways per phase with One
WAPDA
21 - 33

34469.72

-do-

21

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Specification
5

Description

Unit

Rate (Rs)

2
I/C circuit breaker 100 Amps. T.P.
and outgoing
breaker
6-30
Amps. complete with N link
recessed in wall.

22

Providing and fixing of distribution


board 100 Amps, 400 volts 10-ways
per phase with 1-No.I/C circuit
breaker 100 Amps. T.P. and
outgoing circuit breaker 6-30 Amps.
complete with volt metre selector
switch, phase indication light &
Neutral link etc. recessed in wall.

each

36472.87

21.3

23

Providing and fixing of distribution


board three phase 150/200 Amps,
400 volts 10-ways per phase with
1-N0. I/C circuit breaker 150/200
Amps. T.P.and outgoing circuit
breaker 6-30 Amps. complete with
volt, metre, selector, switch, phase
indication light & N link etc.
recessed in wall.

each

52681.48

-do-

24

Providing and fixing of distribution


board 3-phase 400 volts 12-ways
per phase with 1-No. I/C circuit
breaker 150/200 Amps. T.P.and
outgoing circuit breaker 6-30 Amps.
complete with volt, metre, selector,
switch, phase indication light & N
link etc. recessed in wall.

each

53168.16

-do-

25

Providing and fixing of distribution


board 3-phase 400 volts 14-ways
per phase with 1-No.I/C circuit
breaker 200 Amps. T.P. and
outgoing circuit breaker 6-30 Amps.
complete with volt, metre, ampere
Metre, Selector switch, phase
indication light, C.T's & & N link
etc. recessed in wall.

each

72583.68

-do-

D)

Change-over Switches:

26

Providing
and
fixing
D.P.I/C
change-over switch 500 volts,
15 Amps, on a prepared board

each

865.69

-do-

27

Providing
and
fixing
D.P.I/C
change-over switch 500 volts,
30 Amps, on a prepared board

each

1269.79

-do-

28

Providing
and
fixing
D.P.I/C
change-over switch 500 volts,
60 Amps, on a prepared board.

each

1727.41

-do-

WAPDA

Remark

21 - 34

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
29

Description

Unit

Rate (Rs)

2
Providing
and
fixing
T.P.I/C
change-over switch 500 volts,
15 Amps, on a prepared board

3
each

4
1586.34

Specification
5
21.3

30

Providing
and
fixing
T.P.I/C
change-over switch 500 volts,
30 Amps, on a prepared board

each

2151.63

-do-

31

Providing
and
fixing
T.P.I/C
change-over switch 500 volts,
60 Amps, on a prepared board

each

2505.75

-do-

E)

Junction Boxes:

32

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 100 Amps in
19 mm x 4 mm section with
chamber of overall size 609 mm x
336 mm.

each

4773.35

-do-

33

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 100 Amps in
19 mm x 4 mm section with
chamber of overall size 457 mm x
336 mm.

each

4303.13

21.3

34

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 200 Amps in
25.4mm x 5.5 mm section with
chamber of overall size 914 mm x
419 mm.

each

7595.41

-do-

35

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 200 Amps in
25.4mm x 5.5mm section with
chamber of overall size 914 mm x
419 mm.

each

11119.90

-do-

36

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 200 Amps in
25.4mm x 5.5mm section with
chamber of overall size 137 mm x
419 mm .

each

16265.63

-do-

37

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 300 Amps in
31.7mm x 6.3mm section with
chamber of overall size 609 mm x
419 mm.

each

8325.31

-do-

WAPDA

Remark

21 - 35

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1
38

Description

Unit

Rate (Rs)

2
Providing and fixing on a prepared
board iron-clad bus bar with
4 copper strips of 200 Amps in
31.7mm x 6.3mm section with
chamber of overall size 914 mm x
419 mm.

3
each

4
12439.75

Specification
5
21.3

39

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 200 Amps in
31.7mm x 6.3mm section
with
chamber of overall size 914 mm x
419 mm.

each

17206.06

-do-

40

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 500 Amps
in50.8 mm x 6.3 mm section with
chamber of overall size 914 mm x
533 mm.

each

39547.55

-do-

41

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 200 Amps in
50.8 mm x 6.3 mm section with
chamber of overall size 1371mm x
533 mm.

each

26525.60

-do-

42

Providing and fixing on a prepared


board iron-clad bus bar with
4 copper strips of 200 Amps in
50.8 mm x 6.3 mm section with
chamber of overall size 1828 mm x
533 mm.

each

52630.05

-do-

WAPDA

21 - 36

Remark
6

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

A-II. Internal Electrification of Building


Sr.
No.
1
A)

Description

Unit

Rate (Rs)

Remark
6

PVC insulated 4 core copper cables

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 3/.029(2.5 mm2)
in existing trench/tray.

138.97

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 7/.029(2.5 mm2)
in existing trench/tray.

280.37

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 7/.036(4.0 mm2)
in existing trench/tray.

420.45

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 7/.044(6 mm2) in
existing trench/tray.

609.02

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 7/.052(10 mm2)
in existing trench/tray.

847.54

Supply and erection of PVC


insulated PVC Sheathed 4 core
copper cable size 7/.064(16 mm2)
in existing trench/tray.

1254.80

B)

PVC Insulated Single Core Copper


Cables:

Supply and erection of PVC


insulated copper cable, single core
1.5 mm2 (3/.029) in existing PVC
Duct / MS channel.

34.12

Supply and erection of PVC


insulated copper cable, single core
2.5 mm2 (7/.029) in existing PVC
Duct / MS channel.

67.70

Supply and erection of PVC


insulated copper cable, single core
4.0 mm2 (7/.036) in existing PVC
Duct / MS channel.

100.65

Supply & erection of PVC insulated


m
copper cable, single core 6.0 mm2
WAPDA
21 - 37

145.61

10

Specification
5

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Description

Unit

Rate (Rs)

2
(7/.044) in existing PVC Duct / MS
channel.

11

Supply & erection of PVC insulated


copper cable, single core 10.0 mm2
(7/.052) in existing PVC Duct / MS
channel.

199.33

12

Supply & erection of PVC insulated


copper cable, single core 16.0 mm2
(7/.064) in existing PVC Duct / MS
channel.

296.45

C)

Supply & erection of PVC insulated


copper flexible cable, two core
14/.0076 in existing PVC Duct / MS
channel.

44.99

14

Supply & erection of PVC insulated


copper flexible cable, two core
23/.0076 in existing PVC Duct / MS
channel.

58.29

15

Supply & erection of PVC insulated


copper flexible cable, two core
40/.0076 in existing PVC Duct / MS
channel.

80.93

16

Supply & erection of PVC insulated


copper flexible cable, two core
70/.0076 in existing PVC Duct / MS
channel.

129.28

17

Supply & erection of PVC insulated


copper flexible cable, two core
110/.0076 in existing PVC Duct /
MS channel.

184.97

18

Supply & erection of PVC insulated


copper flexible cable, two core
162/.0076 in existing PVC Duct /
MS channel.

263.72

PVC Ducts with cover:

Providing & fixing of PVC Ducts


16mm x 16mm on surface

79.86

Providing & fixing of PVC Ducts


16mm x 25mm on surface

90.56

WAPDA

Remark

PVC Insulated Two Core flexible


Copper Cables:

13

D)

Specification
5

21 - 38

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Description

Unit

2
Providing & fixing of PVC Ducts
16mm x 38mm on surface

3
m

4
120.51

Providing & fixing of PVC Ducts


25mm x 25mm on surface

146.18

Providing & fixing of PVC Ducts


25mm x 38mm on surface

201.79

Providing & fixing of PVC Ducts


40mm x 40mm on surface

227.11

Providing and fixing of M S Channel


455x455mm (1.5x1.5'') with cover
18 SWG powder coated including
all accessories.

m.

445.66

Providing and fixing of Power Outlet


board for computer housing powder
coated 18 SWG 200x305x75mm
(8" x 12" x 3") having German
Socket 02 Nos., Power plug flat pin
01 No. Light Plug 01 No., Double
Gang Switch 01 No. & MCB 6-15 A
01 No. (all switches/ sockets etc
Legrand France or equivalent)

no

2995.70

Providing and fixing of Power Outlet


board for Photocopier housing
powder
coated
18
SWG
200x150x60mm (8" x 6" x 2.5")
having Power plug flat pin 01 No.
Light Plug 01 No., & MCB 6-15 A
01 No. (all switches/ sockets etc
Legrand France or equivalent )

no

1993.51

E)

Rate (Rs)

Remark
6

Exhaust Fans metal body:

Providing and fixing of Exhaust fan


150mm (6) dia Metal body best
quality (i.e. Royal, GFC, Pak etc)

no

2258.73

Providing and fixing of Exhaust fan


200mm (8) dia Metal body best
quality (i.e. Royal, GFC, Pak etc)

no

1880.47

Providing and fixing of Exhaust fan


250mm (10) dia Metal body best
quality (i.e. Royal, GFC, Pak etc)

no

2076.12

Providing and fixing of Exhaust fan


305mm (12) dia Metal body best
quality (i.e. Royal GFC, Pak etc)

no

2258.73

WAPDA

Specification
5

21 - 39

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Description

Unit

2
Providing and fixing of Exhaust fan
405mm (16) dia Metal body best
quality (i.e. Royal GFC, Pak etc)

3
no

4
3341.36

Providing and fixing of Exhaust fan


455mm (18) dia Metal body best
quality (i.e. Royal GFC, Pak etc)

no

3503.32

Providing and fixing of Exhaust fan


505mm (20) dia Metal body best
quality (i.e. Royal, GFC, Pak etc)

no

3907.68

Providing and fixing of Exhaust fan


605mm (24) dia Metal body best
quality (i.e. Royal GFC, Pak etc)

no

4325.08

F)

Rate (Rs)

Providing and fixing of Exhaust fan


150mm (6) dia Plastic body best
quality (i.e. Royal, GFC, Pak etc)

no

1635.90

10

Providing and fixing of Exhaust fan


200mm (8) dia Plastic body best
quality (i.e. Royal, GFC, Pak etc)

no

1988.08

11

Providing and fixing of Exhaust fan


250mm (10) dia Plastic body best
quality (i.e. Royal, GFC, Pak etc)

no

6734.81

12

Providing and fixing of Exhaust fan


305mm (12) dia Plastic body best
quality (i.e. Royal, GFC, Pak etc)

no

2262.00

Bracket Fans:

13

Providing and fixing of Bracket fan


305mm (12) best quality (i.e.
Royal, GFC, Pak etc)

no

2379.39

14

Providing and fixing of Bracket fan


355mm (14)
best quality (i.e.
Royal, GFC, Pak etc)

no

2901.14

15

Providing and fixing of Bracket fan


405mm (16)
best quality (i.e.
Royal, GFC, Pak etc)

no

2966.36

16

Providing and fixing of Bracket fan


455mm (18) best quality (i.e.
Royal, GFC, Pak etc)

no

3044.62

Providing and fixing of Bracket fan


no
605mm (24)
best quality (i.e.
Royal, GFC, Pak etc)
WAPDA
21 - 40

4453.34

17

Remark

Exhaust Fans plastic body:

G)

Specification
5

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

18

H)

Description

Unit

Rate (Rs)

2
Providing and fixing of Bracket fan
355mm (14) Louver Type best
quality (i.e. Royal, GFC, Pak etc)

3
no

4
2914.18

Remark
6

Indoor type lights:

Providing and fixing of Down Light


100 mm / 125 mm (4" / 5) Dia
complete with Energy Saver 23 W

no

640.23

Providing and fixing Recessed


Mounting Light Fixture 605x605mm
(2 x 2) (4 X 18W PHILIPS TBS088/418 G2 or equivalent) complete
with 4XTDL-18W/54 & 4X20W
Starter.

no

3801.15

Providing and fixing of Indoor Light


Fixture Batten Type 1 x TLD-36W
(Philips TMS/015/136 or equivalent)
complete with Chock 1xTLD36W/54 & 2 x 40W starter & chain
for suspension mounting.

no

1520.68

Providing and fixing of Indoor Light


Fixture Batten Type 1 x TLD-36W
(Philips TMS/015/136 or equivalent)
complete with Electronic Ballast etc.

no

2544.61

Providing and fixing of Indoor Light


Fixture Batten Type 2 x TLD-36W
(Philips TMS/015/236 or equivalent)
complete with Chock 2xTLD36W/54 & 2 x 40W starter & chain
for suspension mounting.

no

2466.35

Providing and fixing of Indoor Light


Fixture Batten Type 2 x TLD-36W
(Philips TMS/015/236 or equivalent)
complete with Electronic Ballast.

no

3164.19

I)

Specification
5

Cable Tray:
7

Providing and fixing of Cable Tray


230x75mm (9 x 3) with angle
support

1579.42

Providing and fixing of Cable Tray


100x75mm (4 x 3) with angle
support

1058.89

WAPDA

21 - 41

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

B. O/H Transmission & Distribution


Sr.
No.
1
A)

Description

Unit

Rate (Rs)

Specification
5

Remark
6

Erecting Structures/Poles
1 Collection from designated stores,
construction of foundation &
erection of given H.T. structures 36'
with complete foundation size
610x610x1981 mm as per WAPDA
Specification & backfilling.

each

7033.26

P-34
(1967)

2 Collection from designated stores,


Installation and erection of H.T.
P.C. Pole with backfilling as per
Wapda Specifications.

each

3014.25

P-5
(1967)

3 Collection from designated stores,


Installation and erection of L.T. P.C.
Pole with backfilling as per WAPDA
Specifications.

each

2210.45

-do-

1 Collection from designated stores,


Installation
and
earthing
arrangements for
H.T. steel
structures as per Wapda Drawing
No.PDW/DF-246

each

401.90

2 Collection from designated stores,


Installation for arrangement for L.T.
tubular pole as per Wapda Drawing
No.PDW/DF-247.

each

301.43

3 Collection from designated stores,


Installation for arrangement for L.T.
steel structure pole as per Wapda
Drawing No.PDW/DF-246.

each

401.90

4 Collection from designated stores,


Installation of earthing arrangement
(Configuration for Dist. Transformer
on single structure according to
specification as per Drawing
No.PDW/DF-263.

each

1004.75

5 Collection from designated stores,


construction of foundations and
erection of L.T steel structures
9.49metre (31ft) with complete
foundation size 508x508x1829 mm
and back filling as per WAPDA
Specification.

each

4014.99

B)

WAPDA

Earthing of Structures/Poles/SubStation Capacitors

21 - 42

P-34
(1967)

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Description

Unit

Rate (Rs)

Specification
5

6 Collection from designated stores,


Installation
of
earth
rod
(configuration)
for
distribution
transformer
on
double
structures/poles
according
to
Wapda Drawing No.PDW/DF-264.

each

1205.70

7 Collection from designated stores,


Installation
of
earthing
arrangements for 300/600 KVARH
Capacitor as per Wapda drawing
No.PDW/DF-262.

each

502.38

1 Collection from designated stores,


Installation of wooden cross arms
Wapda spec. P-1:76 on H.T.
Structures 100x125x200 mm size,
complete with nuts, bolts, washers
etc as required as per Drawing
No.ES/DD-14-1L

each

150.71

P-1:76
(1967)

2 Collection from designated stores,


Installation of double cross arms on
H.T. steel pole 100x125x200 mm
size, complete with clamps, nuts,
washers as required as per
Drawing No.ES/DD-2L.

each

301.43

-do-

3 Collection from designated stores,


Installation of wooden cross arms
size 100x125x200 mm on H.T. steel
pole single dead end assembly with
all nuts, bolts, washers etc as
required as per Drawing No.ES/D7L.

each

301.43

-do-

4 Collection from designated stores,


Installation of OFF set single cross
arms size 100x125x200 mm
assembly H.T. steel per Drawing
No.ES/DD-15L.

each

301.43

-do-

each

30.15

P-24:82
P-6 (1967)

2 Collection from designated stores,


each
Installation and fixing of 11 KV Pin
insulators with Pins on angle iron XWAPDA
21 - 43

30.15

C)

D)

Remark
6

Cross Arms (11 KV Overhead Lines):

Insulators (11 KV):


1 Collection from designated stores,
Installation of 11 KV Pin insulator
with 11KV Pin as per spec. No.P24:82 on wooden cross arms as per
Wapda spec. No. P-6 with washers
etc.

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Description

Unit

Rate (Rs)

2
arms as per Wapda spec. No.DDS-12.

3 Collection from designated stores,


Installation & fixing of 11 KV Disc
insulator as per spec. No.P-7:66 on
wooden X-arms dead on assembly
single as per WAPDA Drawing
No.8L.

Specification
5
P-24:82
P-6 (1967)

each

100.48

P-7:66
(1967)

1 Collection from designated stores &


Stringing of given aluminium
conductor Gnat size 7/.089 single
phase 2-wire L.T. 230 V line

per km

8038.01

2 Collection from designated stores &


Stringing of given aluminium
conductor ANT size 7/.122 single
phase 2-wire L.T. 230 V line

per km

8038.01

3 Collection from designated stores &


Stringing of given aluminium
conductor WASP size 7/.173 single
phase 2-wire L.T. 230 V line

per km

8038.01

4 Collection from designated stores &


Stringing of given aluminium
conductor Gnat size 7/.089 3-phase
4-wire L.T. 400 V line

per km

10047.51

5 Collection from designated stores &


Stringing of given aluminium
conductor ANT size 7/.122 3-phase
4-wire L.T. 400 V line

per km

10047.51

6 Collection from designated stores &


Stringing of given aluminium
conductor WASP size 7/.173 3phase 4-wire L.T. 400 V line

per km

10047.51

7 Collection from designated stores &


Stringing of given ACSR Gopher
conductor size 7/.093 for 3-phase
11 KV line.

per km

11052.26

8 Collection from designated stores &


Stringing of given ACSR RABBIT
conductor size 7/.132 for 3-phase
11 KV line.

per km

13061.76

9 Collection from designated stores &


Stringing of given ACSR DOG
conductor for 3-phase 11 KV line.

per km

16076.01

E)

Remark
6

Stringing of Conductors:

WAPDA

21 - 44

WCSR-2013 (Zone-2)

SECTION 21 ELECTRIFICATION

Sr.
No.
1

Description

Unit

Rate (Rs)

Specification
5

10 Collection from designated stores &


Stringing of given ACSR OSPREY
conductor for 3-phase 11 KV line.

per km

28133.02

11 Collection from designated stores &


Stringing of given ACSR PANTHER
conductor for 3-phase 11 KV line.

per km

28133.02

each

502.38

1 Installation and fixing of ordinary


bulb fitting (complete) for street light
as per WAPDA specification.

each

140.67

2 Installation and fixing of tube light


(single) fitting complete for street
light as per WAPDA specification.

each

200.95

3 Installation and fixing of Mercury


bulb fitting (complete) for street light
as per WAPDA specification.

each

200.95

F)

Remark
6

Stay Set
1 Collection from designated stores &
installation and fixing of stay set
complete.

G)

Street Lights

WAPDA

21 - 45

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

SECTION-22

BASIC RATES OF MATERIAL FOR CIVIL WORKS


Sr.
No.

Name of Article

Unit

Rate ( Rs.)

A. C. Pipe 100mm (4")


A. C. Pipe 150mm (6")

3
m
m

A. C. Pipe 200mm (8")

1,479

4
5

A. C. Pipe 250mm (10")


A. C. Pipe 300mm (12")

m
m

2,386
3,194

A. C. Pipe 400mm (16")

5,261

A. C. Pipe 75mm (3")

319

8
9

Acid carbolic
Acoustic Tile false ceiling (300X300X20mm)

litre
sqm

2,210
185

10

Adhesive

litre

451

11

Admixture (water proofing purpose)

kg

113

12

Aluminum Angle Iron 1.5"x0.5" size

94

13

Aluminum Channel 1.5"x0.5"x0.5" size (U) shape

118

14

Aluminum Door closer (double action)

No.

11,368

15
16

Aluminum Door closer (single action)


Aluminum Joint Cover 3" size (gole)

No.
m

3,241
141

17

Aluminum Anodized Double Leaf

sqm

4,510

18

Aluminum Anodized Fixed Panel

sqm

2,499

19
20

Aluminum Anodized Fly Screen


Aluminum Anodized Frame

sqm
sqm

1,372
3,758

21

Aluminum Anodized Louver

sqm

6,013

22

Aluminium Window

sqm

3,750

23
24

Anchor bolt & Nut


Anchorage cones in sets for 12/0.276" cable

kg
Set

81
1,330

25

Andrine

kg

2,954

26

Bamboo (2.45 to 3 m long & 65 to 125 mm .)

No.

155

27
28

Bamboo (3.1 to 3.7 m long & 65 to 125 mm .)


Bamboo (3.7 to 4.3 m long & 65 to 125 mm .)

No.
No.

182
215

29

Bamboo (4.3 to 4.9 m long & 65 to 125 mm mm .)

No.

245

30

Bamboo (4.9 to 6.1 m long & 65 to 125 mm mm .)

No.

305

31
32

Bamboo (normal size)


Bamboo (small size)

No.
No.

94
68

33

Barbed wire

kg.

112

34

No.
No.

45

35

Basket (required during road surfacing)


Bath Tub (Plain)

4,059

36

Bath Tub (With Arm Rest)

No.

6,765

37

BCP Connection 13mm (1/2")

No.

79

38

Bent metal 16SWG, 345mm wide (3'x7')


Bent metal 16SWG, 250mm wide (2.5'x7')

No.
No.

4,500

39
WAPDA

22-1

481
925

3,000
WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

1
Bewelled Nuts
Bhoosa

No.
kg.

43

Bib Tap 13mm (1/2")


Bib Tap 20mm (3/4")

No.
No.

96
132

44

Bib Tap 25mm (1")

No.

180

45
46

Bidet Complete
Binder (required during road surfacing)

No.
kg

4,538
23

47

Binding Wire

kg.

105

48

Bitumen

49
50

Bitumen washers
Black Japan Paint

No.
litre

2
94

51

Bolt 1/2"(13mm) 3"(75 mm) long

kg.

60

52

Bolts, nuts & washer

No.

60

53
54

Bolts, nuts, nail etc


Bolts, nuts, washers, brackets, hooks

kg.
No.

60
9

55

Bond Cement

cum

550

56

Bowl Valve

No.

135

57

Brass Ball Valve 13mm (1/2")

No.

58

Brass Ball Valve 20mm (3/4")

No.

192
271

59

Brass Ball Valve 25mm (1")

No.

406

60

Brass Ball Valve 32mm (1.25")

No.

778

61
62

Brass Ball Valve 40mm (1.5")


Brass Ball Valve 75 mm (3")

No.
No.

1,150
1,556

63

Brass Bib Tap 13mm (1/2")

No.

113

64

Brass Finger Plates

No.

94

65

Brass Hook

66
67

Brass P. Trap 32mm (1.25")


Brass P. Trap 40mm (1.5")

Packet
(100 Nos.)
No.
No.

68

Brass S. Trap 32mm (1.25")

No.

699

69

Brass S. Trap 40mm (1.5")

No.

981

70

Brass Screw 1"(25mm)

Packet
(100 Nos.)

400

71

Brass Screw 1.5"(40 mm)

Packet
(100 Nos.)

500

72

Brass Sliding Bolt (250 mm)

No.

730

73

No.
m

900

74

Brass Sliding Bolt (300mm)


Brass strainer 100mm (4")

1,954

75

Brass strainer 125mm (5")

3,129

76

Brass strainer 150mm (6")

3,007

77

Brass strainer 175mm (7")

78

Brass strainer 200mm (8")

3,335
3,833

40
41
42

WAPDA

M. Ton

22-2

85,000

4,000
699
958

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

Brass strainer 225mm (9")


Brass strainer 250mm (10")

m
m

4,388

82

Brass strainer 300mm (12")


Brass strainer 375mm (15")

m
m

6,832
10,645

83

Brass strainer 40mm (1.5")

658

84
85

Brass strainer 50mm (2")


Brass strainer 75mm (3")

m
m

911
1,146

86

Brick 230x115x75mm

87
88

1
79
80
81

4,895

100 Nos.

700

Brick/Stone Ballast 1.5" size (40 mm)

cum

788

89

Brick Tiles coping (300x150x40mm)


Brick/Stone Ballast (13 mm)

100 Nos.
cum

1,100
788

90

Bricks (Standard Size)

1000 Nos.

700

91

Bricks Tiles (9"x4.5"x1.5")(230x115x40mm)

100 Nos.

600

92
93

Brick tiles (12"x6"x1") (300x150x40mm)


Broken Bricks

100 Nos.
cum

900
621

94

Brush 2-1/2" (65 mm)

No.

243

95

Brush 4" (100 mm)

No.

175

96

Building Paper 2 Ply

sqm

97

Building Stone (Ordinary)

cum

136
1,291

98

Burnt Bricks

100 Nos.

700

99

Burnt Clay Tiles (300x150x32mm)

100 Nos.

400

100
101

Burnt Clay Tiles (300x150x50mm)


Bush Wood

100 Nos.
kg

600
2

102

C.I Brackets (For sink)

pair

90

103

C.I Brackets (For wash hand basin)

pair

124

104
105

C.I. Cistern (13.5 litre Capacity)


C.I. Cistern (4.5 litre Capacity)

No.
No.

1,240
1,056

106

C.I. Cover with frame 300mm (12")

No.

338

107

C.I. Cover with frame 450mm (18")

No.

108

C.I. Grating 150x150mm

No.

676
32

109

C.I. Grating for Floor Trap 100x50mm

No.

28

110

C.I. Head 3"(75 mm)

No.

208

111

C.I. Head 4"(100 mm)

No.

112

C.I. Pipe 4"(115 mm)

334
1,398

113

C.I. Pipe (sandcast) 100mm (4")

1,274

114

C.I. Pipe (sandcast) 50mm (2")

851

115
116

C.I. Pipe 10" (250 mm)


C.I. Pipe 12" (300 mm)

m
m

7,723
9,467

117

C.I. Pipe 13mm (1/2")

96

118

C.I. Pipe 14" (375 mm)

11,211

119

C.I. Pipe 2" (50 mm)

1,018

WAPDA

22-3

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

1
C.I. Pipe 2.5" (65 mm)
C.I. Pipe 20mm (3/4")

m
m

1,059

123

C.I. Pipe 25mm (1")


C.I. Pipe 90 mm ( 3")

m
m

163
1,099

124

C.I. Pipe 75 mm (3)

1,099

125
126

C.I. Pipe 32mm (1.25")


C.I. Pipe 100 mm (4")

m
m

179
1,398

127

C.I. Pipe 40mm (1.5")

128

C.I. Pipe 125mm (5")

222

129
130

C.I. Pipe 150mm (6")


C.I. Pipe 175mm (7")

m
m

1,945
2,492
4,236

131

C.I. Pipe 200mm (8")

5,980

132

C.I. Shoes, bends, Offsets

each.

133
134

C.I. Specials 100mm (4")


C.I. Specials 50mm (2")

No.
No.

135

C.P Brass Waste Pipe 32mm (1.25")

No.

136

C.P Brass Waste Pipe 40mm (1.5")

No.

137

C.P Waste Coupling 32mm (1.25")

No.

138

C.P Waste Coupling 40mm (1.5")

No.

139

C.P. Bib Cock 13mm (1/2")

No.

140

C.P. Bib Tap 13mm (1/2")

No.

141
142

C.P. Bib Tap 20mm (3/4")


C.P. Bottle Trap with C.P. waste pipe 32mm (1.25")

No.
No.

143

C.P. Grating for Floor Trap 100x50mm

No.

144

C.P. Knob

No.

145
146

C.P. mixing valve


C.P. Pillar cock 13mm (1/2")

No.
No.

147

C.P. Pillar cock 20mm (3/4")

No.

148

C.P. Rod

149

C.P. shower arm 13mm (1/2")

No.

150

C.P. Shower Rose 13mm x 100mm

No.

151

C.P. Stop Cock 13mm (1/2")

No.

152

C.P. Tee Stop Cock 13mm (1/2")

No.

153

C.P. Tee Stop Cock 20mm (3/4")

No.

154

C.P.Stop Cock 20mm (3/4")

No.

155

Cane Bamboo

kg.

156
157

Cane Plastic
Carbon (Low) Steel

kg.
kg

158

Catcher

No.

159

Caustic Soda

kg.

160

Cement

bag

120
121
122

WAPDA

22-4

111

520
263
180
517
571
192
361
376
342
462
789
39
15
1,127
357
489
15
1,033
195
338
282
406
316
698
235
78
25
100
440
WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)
4

Cement Concrete Tiles (150x150x20 mm)


Cement Concrete Tiles (200x200x20 mm)

100 Nos.
100 Nos.

1,500

164

Cement Concrete Tiles (225x225x20 mm)


Cement Concrete Tiles (300x300x25 mm)

100 Nos.
100 Nos.

1,800
2,300

165

Cement White

bag

678

166
167

Centring shuttering
Ceramic tile light color glazed finish (150X150mm)

cum
sqm

940
690

168

Ceramic tile light color glazed finish (200X200mm)

sqm

630

169

Ceramic tile light color glazed finish (300X300mm)

sqm

643

170
171

Ceramic tile light color glazed finish (400X400mm)


Ceramic tile light color matt finish (150X150mm)

sqm
sqm

893
725

172

Ceramic tile light color matt finish (200X200mm)

sqm

710

173

Ceramic tile light color matt finish (300X300mm)

sqm

636

174
175

Ceramic tile light color matt finish (400X400mm)


Chalk

sqm
kg

690
13

176

Charcoal

kg.

12

177

Chisel

No.

56

178

Chip Board 1/2" (13 mm) thick

sqm

179

Chip Board 3/4" (20mm) thick

sqm

302
341

180

Cinder

cum

312

181

Clamp 3" (75 mm)

No.

28

182
183

Clamp 4" (100 mm)


Cloth for Flags

No.
m

65
23

184

Coirban

kg

113

185

Colchisin

kg

2,193

186
187

Coloured Cement Tiles (225x225x20mm)


Coloured Glazed Tiles (150x150x6mm)

100 Nos.
100 Nos.

3,100
2,600

188

Colouring material

kg

113

189

Concure 90

litre

190

Conmix SP4

litre

55
90

191

Cooking Range (3 burner / oven)

No.

13,153

192

Copper Pipe 6mm to 10mm

193

161
162
163

1,600

150

Corrugated A.C. Sheets

sqm

194

Corrugated ridge sheets

pair

531
106

195

Cotton Bag (200-250 kg)

No.

51

196

Cotton Bag (50 kg)

No.

197
198

Cotton Waste
Cow dung

kg
cum

38
3,251

199

Creosote Paint

litre

105

200

Curtain Railing (C-Section)

93

201

Dampo

kg

103

WAPDA

22-5

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)
4

Dawan
Diluted Termite Proofing Solution

kg
litre

1,115

205

Deodar Wood
Dhajji

cum
kg

141,280
9

206

Diesel Oil

litre

110

207
208

Distemper
Door Handle

kg
No.

45
125

209

Door Lock Anodised

No.

1,879

210

Door Stop

No.

11

211
212

Double Action Hinges 5" (125 mm) (Imported)


Double Action Hinges 5" (125 mm) (Local)

pair
pair

1,000
250

213

Double Burner (sui gas)

No.

733

214

Drawer Lock

No.

49

215
216

Drawer Railing
Dressed Stone

No.
cum

160
1,483

217

Earth (fine Clay)

cum

399

218

Earth (ordinary)

cum

399

219

Elbow 100 mm 45 degree

No.

220

Electrode

Packet

564
338

221

Emulsion

litre

251

222

Enamel Synthetic

litre

480

223
224

Expanded Metal 1/2" - 3/4"(13 to 20mm) Mesh


Fence Handle

sqm
No.

364
30

225

Ferrule 13mm (1/2")

No.

96

226

Ferrule 20mm (3/4")

No.

132

227
228

Ferrule 25mm (1")


Fiber Glass Pipe 150mm (6")

No.
m

199
3,461

229

Fiber Glass Pipe 200mm (8")

4,038

230

Fiber Glass Pipe 250mm (10")

231

Fiber Glass Pipe 300mm (12")

4,976
6,552

232

Fiber Glass Pipe 450mm (18")

9,858

233

Fiber Glass strainer 150mm (6")

4,395

234

Fiber Glass strainer 200mm (8")

235

Fiber Glass strainer 250mm (10")

5,252
6,509

236

Fiber Glass strainer 300mm (12")

8,247

237

Fiber Glass strainer 450mm (18")

12,909

238
239

Fiber Sheet 3ply


Fiber Sheet 5ply

sqm
sqm

969
1,500

240

Filler Dust

cum

526

241

Fine grit

cum

1,381

242

Fine Powder Murum

cum

394

202
203
204

WAPDA

22-6

75

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

1
243
244

Fire brick
Fire hydrant 50mm (2") (Pak made)

100 Nos.
No.

246

Fire hydrant 65mm (2.5") (Pak made)


Fixation material for Gully Trap

No.
kg

247

Flaps (including hinges)

No.

248
249

Floor Trap 100x50mm


Flush Door (Complete)

No.
sqm

250

Foundation Bolt Template Drawing No. PDW/TC 263

No.

251

Frame for cooking range

No.

252
253

French Polish
Fuel wood

litre
kg

254

G.I Pipe 65 mm (2.5" )

255

G.I Pipe 100 mm (4" )

256
257

G.I Pipe 125 mm (5" )


G.I Pipe 13 mm (1/2" )

m
m

258

G.I Pipe 150 mm (6" )

259

G.I Pipe 20 mm (3/4" )

260

G.I Pipe 25 mm (1" )

261

G.I Pipe 30 mm (1.25" )

262

G.I Pipe 40 mm (1.5" )

263

G.I Pipe 50 mm (2" )

264
265

G.I Pipe 75 mm (3" )


G.I Sheet corrugated

m
kg.

266

G.I Sheet Gutter

267

G.I Sheet plain

kg.

268
269

G.I. Flanges 100mm (4")


G.I. Flanges 125mm (5")

pair
pair

270

G.I. Flanges 13mm (1/2")

pair

271

G.I. Flanges 150mm (6")

pair

272

G.I. Flanges 175mm (7")

pair

273

G.I. Flanges 200mm (8")

pair

274

G.I. Flanges 20mm (3/4")

pair

275

G.I. Flanges 225mm (9")

pair

276

G.I. Flanges 250mm (10")

pair

277

G.I. Flanges 25mm (1")

pair

278

G.I. Flanges 300mm (12")

pair

279
280

G.I. Flanges 32mm (1.25")


G.I. Flanges 375mm (15")

pair
pair

281

G.I. Flanges 40mm (1.5")

pair

282

G.I. Flanges 50mm (2")

pair

283

G.I. Flanges 65mm (2.5")

pair

245

WAPDA

22-7

Rate ( Rs.)
4
2200
911
1,240
366
45
188
2,488
54
32
209
6
656
1,086
1,609
112
1,979
161
229
301
381
477
769
110
23
108
1,250
1,920
124
2,200
2,480
2,760
169
3,040

3,320
207
3,600
248
3,880
650
700
860
WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

1
G.I. Flanges 75mm (3")
G.I. Wire No. 15

pair
kg

1,050

287

Gas Cock 6mm to 10mm (Single way)


Gas Cock 6mm to 10mm (Three way)

No.
No.

278
402

288

Gas Cock 6mm to 10mm (Two way)

No.

346

289
290

Gas Room Heater (double plate)


Gas (LPG)

No.
kg

11,800
122

291

Gate Valve 50 mm (2") .

No.

2,850

292

Gate Valve 75 mm (3")

No.

8,000

293
294

GI Union 75mm(3") (China)


Glass panes 3 mm (16 oz to 18 oz)

No.
sqm

1,028
475

295

Glass panes 5 mm (24 oz to 26 oz)

sqm

564

296

Glass shelf with C.P. Railings (600 mm x 125 mm)

No.

169

297

Glass shelf without C.P. Railings (600 mm x 125 mm)

No.

113

298
299

Glass Strip 1.5" wide 5 mm thickness


Glass Strip 25mm wide 5 mm thickness

m
m

13
10

300

Glass Strip 40mm wide 5 mm thickness

11

301

Glass Strip 50mm wide 5 mm thickness

13

302

Glass Strip 75mm wide 5 mm thickness

303

Glue

kg.

14
90

304

Granite Glazed Tiles

Sqm

1,200

305

Grip Handle

No.

306
307

Gully Trap 100mm of Cast Iron


Gully Trap 100mm of Cement Concrete

No.
No.

643
169

308

Gum, indigo

kg

150

309

Gun powder and fuse

No.

169

310
311

Gypsum
Gypsum board

kg
Sqm

124
120

312

H.T. wire for 12/0.276" cable

kg

109

313
314

Hack saw Blade


Handles 10"(250 mm)

No.
each

38
128

315

Handles 6" (150 mm)

each

57

316

Handles 8" (200 mm)

each

85

317

Hanger Chock

No.

318

Hard Board

sqm

9
346

319

Hard Murum

cum

179

320

Hasp and staple

doz.

406

321
322

Hemp
Helical core for 12/0.276" cable

kg
m

26
15

323

Hinges 10" (250 mm)

doz.

3,072

324

Hinges 2" (50 mm)

doz.

84

284
285
286

WAPDA

22-8

138

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

1
Hinges 4" (100 mm)
Hinges 5" (125 mm)

doz.
doz.

192

328

Hinges 6" (150 mm)


Hinges 8" (200 mm)

doz.
doz.

768
1,536

329

Hold Fast

kg.

83

330
331

Hold Fast (7/8" MS bar with 3/8" flate)


Hold Fast 100 mm (4")

No.
No.

676
28

332

Hold Fast 13mm (1/2")

No.

333

Hold Fast 20mm (3/4")

No.

334
335

Hold Fast 25mm (1")


Hold Fast 32mm (1.25")

No.
No.

7
10

336

Hold Fast 40mm (1.5")

No.

16

337

Hold Fast 50 mm (2") .

No.

26

338
339

Hold Fast 65 mm (2.5")


Hold Fast 75 mm (3")

No.
No.

32
36

340

Hook for fixing Gauge

No.

341

Iron Gratings (for fire places)

sqm

4,510

342

Iron Shoe

No.

343

Jointing Solution

kg

28
366

344

Jute

kg.

170

345

Jute Bag

No.

62

346
347

Kail or Cheer wood


Kerosine Oil

cum
litre

48,565
97

348

Kiker Wood

cum

29,139

325
326
327

396

KSB Pump (2900 rpm 37 metre head) & Seimens Motor


(15 Hp) with Accessories
Laminated (double side) sheet 20mm thick

No.

99,215

Sqm

467

352

Laminated (single side) sheet 20mm thick


Lead

Sqm
kg.

252
147

353

Lead wool

kg

90

354

Lime Slaked (White Lime)

40 kg.

560

355

Lime Unslaked

40 kg.

356

Limpet washers

No.

369
7

357

Linseed Oil

litre

596

358

Lock Superior quality

No.

66

359

Long Hinges

15

360

Low Level Flushing Cistern, 13.5 litre Capacity (Plastic/


Pak Made Best Quality)

No.

852

No.

1,299

litre

221
26

349
350
351

362

Low Level Flushing Cistern, 13.5 litre Capacity (White


glazed earthen ware/ Pak Made Best Quality)
Lubricating Oil

363

Molding Gola 20mm

361

WAPDA

m
22-9

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

Molding Plain 20 mm
M.S. (Plain bars) 40 Grade(Tensile Strength 276 MPa)

m
M. Ton

75,000

367

M.S. (Plain bars) 60 Grade(Tensile Strength 420 MPa)


M.S. Angles

M. Ton
M. Ton

80,000
81,000

368

M.S. Deformed Bars 40 Grade(Tensile Strength 276 MPa)

M. Ton

76,000

369
370

M.S. Deformed Bars 60 Grade(Tensile Strength 420 MPa)


M.S. Flat Iron

M. Ton
kg

82,000
81

371

M.S. Pipe 1.0" (25 mm)

173

372

M.S. Pipe 1.5" (40 mm)

442

373
374

M.S. Pipe 1/2" (13mm)


M.S. Pipe 3/4" (20mm)

m
m

98
139

375

M.S. Pipe Conduit 4" (100 mm)

1,740

376

M.S. Pipe Conduit 5" (125 mm)

2,290

377
378

M.S. Pipe Conduit 6" (150 mm)


M.S. Plates

m
M. Ton

2,990
118,000

379

M.S. Section (Channel)

M. Ton

106,000

380

M.S.Pipe 100mm (4")

1,740

381

M.S.Pipe 125mm (5")

382

M.S.Pipe 150mm (6")

2,290
2,990

383

M.S.Pipe 175mm (7")

4,004

384

M.S.Pipe 200mm (8")

5,018

385
386

M.S.Pipe 225mm (9")


M.S.Pipe 250mm (10")

m
m

6,179
7,340

387

M.S.Pipe 300mm (12")

9,600

388

M.S.Pipe 375mm (15")

14,250

389
390

M.S.Pipe 450mm (18")


M.S.Pipe 50mm (2")

m
m

18,900
605

391

M.S.Pipe 75mm (3")

1,194

392

Main Lock for Iron Gate

No.

393

Manila Rope

kg

1,082
78

394

Manure

cum

291

395

Marble chips

bag

97

396

Marble Flooring 1"(25mm) thick

sqm

397

Marble Flooring 3/4"(19mm) thick

sqm

1,820
1,688

398

Marble Powder

399

Marble Tile (Boticina) 300x300x12mm

sqm

545

400
401

Marble Tile (Boticina) 300x300x20mm


Marble Tile (Boticina) 300x300x25mm

sqm
sqm

696
1,245

402

Mineral Oil

403
404

364
365
366

WAPDA

kg

16

kg

38

Mirror 22" x 16" (550x400mm)(Pak.)

each

500

Mirror 22" x 16" Belgium Genuine(550x400mm)

each

875

22-10

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

litre
cum

5,602

408

Mosaic tiles (6"x6"x3/4")(150x150x20mm)


Mosaic tiles (6"x6"x3/4")(150x150x20mm)

100 Nos.
100 Nos.

409

Mosaic tiles 6"x6"x3/4"(150mmx150mmx20mm)

100 Nos.

1,900
2,400

410
411

Motrice Lock
MS 18 gauge Square tube 32x32mm (1 x 1)

each
m

412

MS Bail Plug 100mm (4")

No.

413

MS Bail Plug 125mm (5")

No.

414
415

MS Bail Plug 150mm (6")


MS Bail Plug 175mm (7")

No.
No.

416

MS Bail Plug 200mm (8")

No.

417

MS Bail Plug 225mm (9")

No.

418

No.
No.

1,052

419

MS Bail Plug 250mm (10")


MS Bail Plug 300mm (12")

420

MS Bail Plug 375mm (15")

No.

421

MS Bail Plug 40mm (1.5")

No.

1,240

422

MS Bail Plug 450mm (18")

No.

423

MS Bail Plug 50mm (2")

No.

424

MS Bail Plug 75mm (3")

No.

425

MS bars (square)

kg

426
427

MS Eye Hook
MS Iron Hook

No.
No.

428

MS sheet 2 mm thick

kg

429

MS Sheet 22 SWG

kg

430
431

MS strap
MS Tee

kg
kg

432

MS Tubular Pipe

433

Muller Tee 20mm

No.

434

Muller Tee 25mm

No.

435

Muller Tee 50mm

No.

436

Munj, ban or patha

kg

437

Neoprene Gasket

kg

438

Nickel Waste Pipe 32mm (1.25")

No.

439

Nickel Waste Pipe 40mm (1.5")

No.

440

Nipple\bush

No.

441
442

Oil and Grease


Oil Bond Distemper

kg.
litre

443

P. Trap CP 32mm (1.25")

No.

444

P. Trap CP 40mm (1.5")

No.

445

Packing Material

kg

405
406
407

WAPDA

Mobil Oil / C. Oil


Mortar (1:2:4)

22-11

381

1,700
516
156
460
564
780
836
883
977
1,127
122
1,644
301
526
79
6
26
92
106
79
79
237
156
738
1,466
53
695
282
304
23
372
152
643
902
94
WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

1
Paint
Partal Wood

litre
cum

42,384

449

Pedistal for Wash Basin


Peeable Regulator

No.
No.

676
361

450

Peet Valve 100mm (4")

No.

2,334

451
452

Peet Valve 13mm (1/2")


Peet Valve 20mm (3/4")

No.
No.

90
130

453

Peet Valve 25mm (1")

No.

192

454

Peet Valve 32mm (1.25")

No.

284

455
456

Peet Valve 40mm (1.5")


Peet Valve 50 mm (2") .

No.
No.

406
571

457

Peet Valve 65 mm (2.5")

No.

1,037

458

Peet Valve 75 mm (3")

No.

1,353

459
460

Peg (wooden)
Petrol

No.
litre

15
103

461

Pigment for cement/concrete

kg.

95

462

Pigment for colour wash

kg.

175

463

Pilchi

cum

464

Pit run gravel/granular material

cum

996
1,691

465

Plain A C sheet False ceiling (1200x1200x6mm)

No.

864

466

Plain Asbestos Cement Sheets

sqm

551

467
468

Plain Concrete block (solid) 200X200X300mm


Plain Concrete block (solid) 150X200X300mm

No.
No.

48
47

469

Plain Concrete block (hollow)200X200X400mm

No.

51

470

Plain Concrete block (hollow) 150X200X400mm

No.

43

471
472

Plain Concrete block (hollow) 150X190X390mm


Plain Concrete block (hollow) 100X190X390mm

No.
No.

44
33

473

Plastic Emulsion Paint

litre

325

474

Plastic Pipe 19 mm (3/4")

475

Ply Wood (3mm)

sqm

47
349

476

Ply Wood (5 mm)

sqm

403

477

Polythene Sheet 0.20 mm thick

kg.

255

478

Private Plantation Wood

kg

479

Putty

kg

2
94

480

PVC class 'B' Pipe 100mm (4")

534

481

PVC class 'B' Pipe 125mm (5")

728

482
483

PVC class 'B' Pipe 150mm (6")


PVC class 'B' Pipe 200mm (8")

m
m

1,031
1,587

484

PVC class 'B' Pipe 250mm (10")

3,109

485

PVC class 'B' Pipe 300mm (12")

4,631

486

PVC class 'B' Pipe 350mm (14")

6,153

446
447
448

WAPDA

22-12

436

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

PVC class 'B' Pipe 75mm (3")


PVC class 'B' strainer 100mm (4")

m
m

352

490

PVC class 'B' strainer 125mm (5")


PVC class 'B' strainer 150mm (6")

m
m

650
919

491

PVC class 'B' strainer 200mm (8")

1,411

492
493

PVC class 'B' strainer 250mm (10")


PVC class 'B' strainer 300mm (12")

m
m

2,766
3,819

494

PVC class 'B' strainer 350mm (14")

4,872

495

PVC class 'B' strainer 75mm (3")

312

496
497

PVC class 'D' Pipe 100mm (4")


PVC class 'D' Pipe 125mm (5")

m
m

831
1,239

498

PVC class 'D' Pipe 150mm (6")

1,798

499

PVC class 'D' Pipe 32mm (1.25")

125

500
501

PVC class 'D' Pipe 40mm (1.5")


PVC class 'D' Pipe 50mm (2")

m
m

175
231

502

PVC class 'D' Pipe 65mm (2.5")

364

503

PVC class 'D' Pipe 75mm (3")

496

504

PVC class 'D' strainer 100mm (4")

505

PVC class 'D' strainer 125mm (5")

807
1,204

506

PVC class 'D' strainer 150mm (6")

1,749

507

PVC class 'D' strainer 32mm (1.25")

112

508
509

PVC class 'D' strainer 40mm (1.5")


PVC class 'D' strainer 50mm (2")

m
m

148
226

510

PVC class 'D' strainer 65mm (2.5")

354

511

PVC class 'D' strainer 75mm (3")

482

512
513

PVC Connection 13mm (1/2")


PVC Flushing Bend 32mm

No.
No.

45
34

514

PVC Flushing Pipe 32mm

No.

19

515

PVC Gasket

kg

516

PVC sockets 75 mm (3") Class 'B'

each

47
38

517

PVC sockets 100 mm (4") Class 'B'

each

74

518

PVC sockets 125 mm (5") Class 'B'

each

153

519

PVC sockets 150 mm (6") Class 'B'

each

520

PVC sockets 200 mm (8") Class 'B'

each

233
379

521

PVC sockets 250 mm (10") Class 'B'

each

447

522

PVC sockets 300 mm (12") Class 'B'

each

517

523
524

PVC sockets 350 mm (14") Class 'B'


PVC sockets 50 mm (2") Class 'D'

each
each

618
24

525

PVC sockets 75 mm (3") Class 'D'

each

62

526

PVC sockets 100 mm (4") Class 'D'

each

94

527

PVC sockets 125 mm (5") Class 'D'

each

237

487
488
489

WAPDA

22-13

458

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

each
sqm

250

531

PVC Waste Pipe 32mm (1.25")


PVC Waste Pipe 40mm (1.5")

No.
No.

34
79

532

PVC water stopper 190 mm wide

357

533
534

R.C.C. Pipe (BSS&ASTM) 4" (100 mm)


R.C.C. Pipe (BSS&ASTM)10"(250mm)

m
m

146
723

535

R.C.C. Pipe (BSS&ASTM)12"(300mm)

851

536

R.C.C. Pipe (BSS&ASTM)15"(375mm)

1,086

537
538

R.C.C. Pipe (BSS&ASTM)18" (450 mm)


R.C.C. Pipe (BSS&ASTM)21"(525mm)

m
m

1,301
1,530

539

R.C.C. Pipe (BSS&ASTM)24" (600 mm)

1,760

540

R.C.C. Pipe (BSS&ASTM)27"(675mm)

2,288

541
542

R.C.C. Pipe (BSS&ASTM)30"(750mm)


R.C.C. Pipe (BSS&ASTM)6" )150 mm

m
m

2,793
381

543

R.C.C. Pipe (BSS&ASTM)7"(175 mm)

570

544

R.C.C. Pipe (BSS&ASTM)8"(200mm)

605

545

R.C.C. Pipe (BSS&ASTM)9"(225 mm)

546

Rawl Plug

No.

616
2

547

Razor Barbed wire

kg

11

548

RCC Pre-stressed Batten

No.

541

549
550

Red Oxide
Reducer 100mm (4")

kg
No.

62
217

551

Reducer 125mm (5")

No.

424

552

Reducer 150mm (6")

No.

630

553
554

Reducer 175mm (7")


Reducer 200mm (8")

No.
No.

837
1,043

555

Reducer 225mm (9")

No.

1,250

556

Reducer 250mm (10")

No.

557

Reducer 300mm (12")

No.

1,456
1,663

558

Reducer 375mm (15")

No.

1,869

559

Reducer 450mm (18")

No.

2,076

560

Reducer 50mm (2")

No.

561

Reducer 75mm (3")

No.

85
121

562

Reducing Elbow 100x50 mm 90 degree

No.

902

563

Reflux valve 100 mm (4")

No.

778

564
565

Retarder Admixture (Conmix P4R)


Rim Lock (Adjustable)

litre
each

40
631

566

Rim Lock 10" (250 mm)

each

591

567

Rolling Spring

No.

19

568

Rubber Bearing for Prestressed Bridges

cu cm

528
529
530

WAPDA

PVC sockets150 mm (6") Class 'D'


PVC Tiles (300x300x3mm)

22-14

540

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

Rubber Plug with Chain 32mm (1.25")


Rubber Plug with Chain 40mm (1.5")

No.
No.

34

572

Rubber Strip (Joint Filler)


Rumbi

m
litre

113
88

573

RW 043 Regulator

No.

1,804

574
575

S. Trap 102mm China ware (Pak.made)


S. Trap CP 32mm (1.25")

No.
No.

79
699

576

S. Trap CP 40mm (1.5")

No.

981

577

Sand (Coarse)

cum

869

578
579

Sand (Fine)
Sand Paper

cum
No.

489
14

580

Saw Dust

kg

20

581

Scarping material for pained brick works

kg

141

582
583

Scrap Wood
Screws

kg
100 Nos.

12
500

584

Seat & Cover (Backelite) for European type W.C

No.

496

585

Seat & Cover (PVC) for European type W.C

No.

372

586

Sheath 1-9/16" i/d 12/0.276"cable

587

Sheet Glass 5mm Plain

sqm

88
475

588

Shutter (MS)

160

589

Simple Burner

No.

180

590
591

Single Burner (sui gas)


Sink stain less steel (50Cm x 100 Cm)

No.
No.

383
2,931

592

Sink stain less steel (50Cm x 120 Cm)

No.

3,270

593

Sink white glazed earthen ware domestic type

No.

2,255

594
595

Sliding Bolt (300 mm)


Sliding Bolt 10" (250 mm)

No.
each

596

Sluice valve 100mm (4")

No.

25,650

597

Sluice valve 125mm (5")

No.

598

Sluice valve 150mm (6")

No.

36,000
4,800

599

Sluice valve 175mm (7")

No.

7,150

600

Sluice valve 200mm (8")

No.

9,500

601

Sluice valve 225mm (9")

No.

602

Sluice valve 250mm (10")

No.

10,213
10,925

603

Sluice valve 300mm (12")

No.

19,110

604

Sluice valve 375mm (15")

No.

27,295

605
606

Sluice valve 50mm (2")


Sluice valve 65mm (2-1/2")

No.
No.

1,165
1,100

607

Sluice valve 75mm (3")

No.

16,500

608

Snowcem Cement Base

pack

1,344

609

Soap Dish (Chromium plated)

No.

1,699

569
570
571

WAPDA

22-15

68

150
125

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

Soap Dish (glazed earthen ware)


Soap Dish (Plastic)

No.
No.

1,133

613

Socket 100mm (4")


Socket 125mm (5")

No.
No.

696
1,529

614

Socket 150mm (6")

No.

2,361

615
616

Socket 175mm (7")


Socket 200mm (8")

No.
No.

3,194
4,026

617

Socket 225mm (9")

No.

4,859

618

Socket 250mm (10")

No.

5,691

619
620

Socket 300mm (12")


Socket 375mm (15")

No.
No.

6,524
7,356

621

Socket 450mm (18")

No.

8,189

622

Socket 50mm (2")

No.

148

623
624

Socket 75mm (3")


Soft board

No.
sqm

475
654

625

Solignum Paint

litre

105

626

Soling Stone 6"x9" (150x230 mm)

cum

394

627

Solvent

litre

628

Specials (pipe fittings)

No.

156
94

629

Spikes, Wire nails

kg.

142

630

Sprit

litre

78

631
632

Spun Yarn
Stack

kg
No.

45
9

633

Staple (heavy)

kg

338

634

Stead Handles

No.

19

635
636

Steam Coal
Steel Bearing for Prestressed Bridges

kg
each

13
5,690

637

Stone (Machine Crushed.)Bajri

cum

1,291

638

Stone (Quarried & Screened)

cum

639

Stone Ballast (Hand Broken)

cum

1,432
1,291

640

Stone Dust

cum

996

641

Stone for Rubbing Floor

No.

156

642

Stone Hammer Dressed

sqm

643

Stone Tiles coping (300x150x40mm)

149
1,700

644

Stop Cock 15mm (1/2")

No.

77

645

Stop Cock 20mm (3/4")

No.

118

646
647

Stop Cock 25mm (1")


Stopper for Window

No.
No.

220
23

648

Sui Gas Metre

No.

5,073

649

Sulphate Resisting Cement

bag

451

650

Surface Box ( 100x100mm)

No.

195

610
611
612

WAPDA

22-16

100 Nos.

566

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)

1
Surface Box ( 230x150mm)
Surface Box (230x230mm)

No.
No.

457

654

Surkhi
Sutlee

cum
kg

322
56

655

Sutlee Nylon (polythene)

kg

94

656
657

Swan Neck Cock 13mm (Single way)


Swan Neck Cock 13mm (Three way)

No.
No.

395
981

658

Swan Neck Cock 13mm (Two way)

No.

879

659

SWG18/1.2mm

sqm

750

660
661

T. Hinges
Teak Wood

doz.
cum

780
215,452

662

Telephone Shower with mixing Valves

No.

2,255

663

Telephone Shower without mixing Valves

No.

622

664
665

Template Drawing No. PDW/TC 263


Termite proofing concentrated

No.
litre

361
1,115

666

Terpantine Oil

litre

147

667

Thermopore sheet (13mm thick)

No.

193

668

Thermopore sheet (40mm thick)

kg

669

Thermosole

sqm

340
267

670

Trough Stone

No

17

671

Timber (Shisham)

cum

61,810

672
673

Toilet Paper Holder (Chromium plated)


Toilet Paper Holder (glazed earthen ware)

No.
No.

1,426
713

674

Toilet Paper Holder (Plastic)

No.

357

675

Tooth Brush Holder & Tooth Paste Dish


(Chromium plated)

No.

1,881

No.

1,254

No.

314

651
652
653

970

677

Tooth Brush Holder & Tooth Paste Dish


(glazed earthen ware)
Tooth Brush Holder & Tooth Paste Dish (Plastic)

678

Towel Rail 500 x 15 mm (Chromium plated)

No.

1,867

679

Towel Rail 600 x 20 mm (Chromium plated)

No.

680

Towel Ring 150 mm i/d (Chromium plated)

No.

2,334
1,407

681

Tower Bolt 4"(100mm)

doz.

216

682

Tower Bolt 6" (150mm)

doz.

348

683
684

Tower Bolt 8" (200 mm)


Tuff tile

doz.
Sqm

384
485

685

Tumbler Holder (Chromium plated)

No.

147

686
687

Tumbler Holder (glazed earthen ware)


Tumbler Holder (Plastic)

No.
No.

214
45

688

Ultra Plasticizer 300

litre

36

689

Ultra superplasticizer 437

litre

690

Urinal white glazed earthen ware

No.

45
825

676

WAPDA

22-17

WCSR-2013 (Zone-2)

SECTION 22 BASIC RATES OF MATERIAL FOR CIVIL WORKS

Sr.
No.

Name of Article

Unit

Rate ( Rs.)
4

Valve 102 mm flanged (China)


Varnish

No.
Litre

2,368

694

Wash Basin 45 cm
Wash Basin 55/56 cm

No.
No.

1,150
1,400

695

Wash Basin 65 cm

No.

1,600

696
697

Washing Powder
Washing Soap

kg
No.

68
30

698

Water Closet European type

No.

1,800

699

Water Geyser 115 litres (25 gallons)

No.

8,456

700
701

Water Geyser 160 litres (35 gallons)


Wax Polish

No.
kg

11,800
156

702

Weather Shield Paint

litre

435

703

Wedge & stakes

cum

470

704
705

Welding rod
White Glazed Tiles (6"x6"x1/4")(150mmx150mmx6mm)

kg.
100 Nos.

122
114

706

White Glazed Water Closet, Squatting Type

No.

23

691
692
693

405

No.

1,033

708

White Glazed Water Closet, Squatting Type Orrissa


pattern (Pak Made Best Quality)
White Paint

litre

225

709

Wire 10 SWG

kg

710

Wire 144 SWG

120
28

711

Wire Brush

No.

79

712

Wire gauze 22 SWG (mesh)

sqm

126

713
714

Wire gauze mesh 144 SWG


Wooden Beading

sqm
m

291
75,163

715

Wooden Plugs

No.

716

Zinc

kg

94

707

WAPDA

22-18

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

SECTION-23

BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS


Sr.
No.
1

Description

Unit

Rate
(Rs.)
4

PVC WIRES
1.

a) PVC insulated single core copper conductor

12

b) PVC insulated single core copper conductor 250/440


Volts size 1/1.38 mm (3/.036)

16

c) PVC insulated single core copper conductor 250/440


Volts size 1/1.78 mm (7/.029)

22

d) PVC insulated single core copper conductor 250/440


Volts size 7/0.85 mm (7/.036)

33

e) PVC insulated single core copper conductor 250/440


Volts size 7/1.04 mm (7/.044)

49

PVC insulated single core copper conductor 250/440


Volts size 1/1.35 mm (7/052)

75

g) PVC insulated single core copper conductor 250/440


Volts size 1/1.70 mm (7/.064)

99

h) PVC insulated single core copper conductor 250/440


Volts size (19/.044)

162

f)

2.

i)

PVC insulated single core copper conductor 660/1100


Volts size 19/1.53 mm (19/.064)

262

j)

PVC insulated single core copper conductor 660/1100


Volts size 19/2.14 mm (19/.083)

298

a) PVC insulated and PVC sheathed single core copper


conductor 250/440 volts size 1/1.13 mm (3/.029)

12

b) PVC insulated and PVC sheathed single core copper


conductor 250/440 volts size 1/1.38 mm (3/.036)

20

c) PVC insulated and PVC sheathed single core copper


conductor 250/440 volts size 7/.058 mm (7/.029)

26

d) PVC insulated and PVC sheathed single core copper


conductor 250/440 volts size 7/.085 mm (7/.036)

39

e) PVC insulated and PVC sheathed single core copper


conductor 250/440 volts size 7/1.04 mm (7/.044)

53

PVC insulated and PVC sheathed single core copper


conductor 250/440 volts size 7/1.4 mm (7/.052)

79

g) PVC insulated and PVC sheathed single core copper


conductor 250/440 volts size 7/1.70 mm (7/.064)

114

a) PVC insulated and PVC sheathed twin core circular


copper conductor flexible wire size16/.20 mm (14/.0076)

37

b) PVC insulated and PVC sheathed twin core circular


copper conductor flexible wire size24/.20 mm (23/.0076)

41

c) PVC insulated and PVC sheathed twin core circular


copper conductor flexible wire size16/.20 mm
(14/.0076)

37

f)

3.

WAPDA

23-1

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1

4.

5.

Rate
(Rs.)
4

Description

Unit

d) PVC insulated and PVC sheathed twin core circular


copper conductor flexible wire size24/.20 mm
(23/.0076)

41

a) PVC insulated and PVC sheathed Two core copper


conductor 250/440 volts size 7/.085 mm (7/.029)

59

b) PVC insulated and PVC sheathed Two core copper


conductor 250/440 volts size 7/.085 mm (7/.036)

87

c) PVC insulated and PVC sheathed Two core copper


conductor 250/440 volts size 7/.1.04 mm (7/.044)

128

d) PVC insulated and PVC sheathed Two core copper


conductor 250/440 volts size 7/1.4 mm (7/.052)

173

e) PVC insulated and PVC sheathed Two core copper


conductor 250/440 volts size 7/1.70 mm (7/.064)

250

a) PVC insulated and PVC sheathed Four core copper


conductor 250/440 volts size 7/.058 mm (7/.029)

124

b) PVC insulated and PVC sheathed Four core copper


conductor 250/440 volts size 7/.085 mm (7/.036)

185

c) PVC insulated and PVC sheathed Four core copper


conductor 250/440 volts size 7/1.04 mm (7/.044)

260

d) PVC insulated and PVC sheathed Four core copper


conductor 250/440 volts size 7/1.40 mm (7/.052)

359

e) PVC insulated and PVC sheathed Four core copper


conductor 250/440 volts size 7/1.70 mm (7/.064)

520

f) PVC insulated and PVC sheathed Four core copper


conductor 250/440 volts size 7/1.40 mm (19/.052)

847

g) PVC insulated and PVC sheathed Four core copper


conductor 250/440 volts size 7/1.70 mm (19/.064)

1,149

h) PVC insulated and PVC sheathed Four core copper


conductor 250/440 volts size 7/2.14 mm (19/.083)

2,197

3,795

a) Steel conduit 19.1 mm gauge 15/16 (3/4)

75

b) Steel conduit 25.4 mm gauge 15/16 (1)

79

c) Steel conduit 31.7 mm gauge 15/16 (1-1/4)

132

d) Steel conduit 38.2 mm gauge 15/16 (1-1/2)

142

e) Steel conduit 50.8 mm gauge 15/16 (2)

225

a) Bend solid dia 19.1 mm (3/4)

doz

355

b) Bend solid dia 25.4 mm (1)

doz

426

c) Bend solid dia 31.7 mm (1-1/4)

doz

709

d) Bend solid dia 38.2 mm (1-1/2)

doz

1,182

e) Bend solid dia 50.8 mm (2)

doz

1,490

i)

PVC insulated and PVC sheathed Four core copper


conductor 250/440 volts size 7/.085 mm (37/.083)
STEEL CONDUITS AND FITTINGS

6.

7.

WAPDA

23-2

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1
8.

9.

10.

11.

12.

13.

14.

WAPDA

Description

Unit

Rate
(Rs.)
4

a) Bend inspection 25.4 mm (1)

doz

335

b) Bend inspection 31.7 mm (1-1/2)

doz

404

c) Bend inspection 38.2 mm (1-1/2)

doz

1,044

d) Bend inspection 50.8 mm (2)

doz

1,458

a) Tee inspection 19.1 mm (3/4)

doz

296

b) Tee inspection 25.4 mm (1)

doz

355

c) Tee inspection 31.7 mm (1-1/4)

doz

384

d) Tee inspection 38.2 mm (1-1/2)

doz

1,064

e) Tee inspection 50.8 mm (2)

doz

1,230

a) Elbow solid 19.1 mm (3/4)

doz

189

b) Elbow solid 25.4 mm (1)

doz

207

c) Elbow solid 31.7 mm (1-1/4)

doz

355

d) Elbow solid 38.2 mm (1-1/2)

doz

434

e) Elbow solid 50.8 mm (2)

doz

788

f) Elbow inspection 19.1 mm (3/4)

doz

296

g) Elbow inspection 31.7 mm (1-1/4)

doz

443

h) Elbow inspection 38.2 mm (1-1/2)

doz

906

i)

doz

1,143

a) Socket 19.1 mm (3/4)

doz

142

b) Socket 25.4 mm (1)

doz

197

c) Socket 31.7 mm (1-1/4)

doz

307

d) Socket 38.2 mm (1-1/2)

doz

520

e) Socket 50.8 mm (2)

doz

757

a) Nipple 19.1 mm (3/4)

doz

189

b) Nipple 25.4 mm (1)

doz

284

c) Nipple 31.7 mm (1-1/4)

doz

315

d) Nipple 38.2 mm (1-1/4)

doz

414

e) Nipple 50.8 mm (2)

doz

709

a) Saddles 19.1 mm (3/4)

doz

128

b) Saddles 25.4 mm (1)

doz

136

c) Saddles 31.7 mm (1-1/4)

doz

217

d) Saddles 38.2 mm (1-1/2)

doz

256

e) Saddles 50.8 mm (2)

doz

370

a) Chuk nuts 19.1 mm (3/4)

doz

71

b) Chuk nuts 25.4 mm (1)

doz

83

c) Chuk nuts 31.7 mm 1-1/4)

doz

130

d) Chuk nuts 38.2 mm (1-1/2)

doz

162

Elbow inspection 50.8 mm (2)

23-3

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1
15.

16.

17.

18.

Description

Unit

3
doz

Rate
(Rs.)
4
284

a) Joint boxes 1,2,3 & 4 way (Aluminum) 19.1 mm (3/4)

doz

256

b) Joint boxes 1,2,3 & 4 way (Aluminum) 25.4 mm (1)

doz

315

c) Joint boxes 1,2,3 & 4 way (Aluminum) 31.7 mm (1-1/4)

doz

709

d) Joint boxes 1,2,3 & 4 way (Aluminum) 58.2 mm (2)

doz

1,281

a) Adopter size 19.1 mm (3/4)

doz

167

b) Adopter size 25.4 mm (1)

doz

189

c) Adopter size 31.7 mm (1-1/4)

doz

276

d) Adopter size 38.2 mm (1-1/2)

doz

367

e) Adopter size 50.8 mm (2)

doz

473

a) Bushes size 19.1 mm (3/4)

doz

213

b) Bushes size 25.4 mm (1)

doz

284

c) Bushes size 31.7 mm (1-1/4)

doz

355

d) Bushes size 38.2 mm (1-1/2)

doz

426

e) Bushes size 50.8 mm (2)

doz

532

a) Flexible pipe size 19.1 mm (3/4)

doz

59

b) Flexible pipe size 25.4 mm (1)

doz

71

c) Flexible pipe size 31.7 mm (1-1/4)

doz

106

d) Flexible pipe size 38.2 mm (1-1/2)

doz

122

e) Flexible pipe size 50.8 mm (2)

doz

148

a) G.I. Pipe dia 15 mm (1/2)

97

b) G.I. Pipe dia 20 mm (3/4)

136

c) G.I. Pipe dia 25 mm (1)

185

d) G.I. Pipe dia 32 mm (1-1/4)

240

e) G.I. Pipe dia 40 mm (1-1/2)

296

f)

G.I. Pipe dia 50 mm (2)

386

g) G.I. Pipe dia 80 mm (3)

603

h) G.I. Pipe dia 100 mm (4)

945

G.I. tee size 15 mm (1/2)

doz

422

a) G.I. tee size 20 mm (3/4)

doz

611

b) G.I. tee size 25 mm (1)

doz

709

c) G.I. tee size 32 mm (1-1/4)

doz

828

d) G.I. tee size 40 mm (1-1/2)

doz

985

e) G.I. tee size 50 mm (2)

doz

1,419

f)

doz

4,729

g) G.I. tee size 80 mm (3)

doz

5,675

h) G.I. tee size 100 mm (4)

doz

8,536

e) Chuk nuts 50.8 mm (2)

G.I. PIPES AND FITTINGS


19.

i)
20.

WAPDA

G.I. tee size 65 mm (2-1/2)

23-4

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1
21.

22.

23.

24.

WAPDA

Description

Unit

Rate
(Rs.)
4

a) Check nut size 15 mm (1/2)

doz

118

b) Check nut size 20 mm (3/4)

doz

142

c) Check nut size 25 mm (1)

doz

213

d) Check nut size 32 mm (1-1/4)

doz

307

e) Check nut size 40 mm (1-1/2)

doz

378

f)

Check nut size 50 mm (2)

doz

757

g) Check nut size 65 mm (2-1/2)

doz

1,419

h) Check nut size 80 mm (3)

doz

2,128

i)

doz

2,483

a) Long bend size 15 mm (1/2)

doz

520

b) Long bend size 20 mm (3/4)

doz

589

c) Long bend size 25 mm (1)

doz

875

d) Long bend size 32 mm (1-1/4)

doz

1,277

e) Long bend size 40 mm (1-1/2)

doz

1,655

f)

Long bend size 50 mm (2)

doz

2,365

g) Long bend size 65 mm (2-1/2)

doz

2,463

h) Long bend size 80 mm (3

doz

5,557

i)

doz

11,350

a) Gate valve size 15 mm (1/2)

doz

631

b) Gate valve size 20 mm (3/4)

doz

780

c) Gate valve size 25 mm (1)

doz

1,182

d) Gate valve size 32 mm (1-1/2)

doz

1,557

e) Gate valve size 40 mm (1-1/2)

doz

1,892

f)

Gate valve size 50 mm (2)

doz

2,838

g) Gate valve size 65 mm (2-1/2)

doz

3,389

h) Gate valve size 80 mm (3)

doz

7,094

i) Gate valve size 100 mm (4)

doz

10,877

a) G.I socket size 13 mm (1/2)

doz

166

b) G.I socket size 20 mm (3/4)

doz

236

c) G.I socket size 25 mm (1)

doz

402

d) G.I socket size 32 mm (1-1/4)

doz

520

e) G.I socket size 40 mm (1-1/2)

doz

709

f)

G.I socket size 50 mm (2)

doz

1,088

g) G.I socket size 65 mm (2-1/2)

doz

1,951

h) G.I socket size 80 mm (3)

doz

2,128

i)

G.I socket size 100 mm (4)

doz

4,769

j) G.I socket size 15 mm (1/2)


k) G.I socket size 20 mm (3/4)

doz
doz

260

Check nut size 100 mm (4)

Long bend size 100 mm (4)

23-5

339
WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1
25.

26.

Description

Unit

Rate
(Rs.)
4

a) G.I union size 25 mm (1)

doz

355

b) G.I union size 32 mm (1-1/4)

doz

394

c) G.I union size 40 mm (1-1/2)

doz

709

d) G.I union size 50 mm (2)

doz

828

e) G.I union size 65 mm (2-1/2)

doz

1,971

f)

doz

2,975

g) G.I union size 100 mm (4)

doz

4,020

a) Flanges size 15 mm (1/2)

doz

69

b) Flanges size 20 mm (3/4)

doz

85

c) Flanges size 25 mm (1)

doz

128

d) Flanges size 32 mm (1-1/4)

doz

146

e) Flanges size 40 mm (1-1/2)

doz

181

f)

Flanges size 50 mm (2)

doz

246

g) Flanges size 65 mm (2-1/2)

doz

382

h) Flanges size 80 mm (3)

doz

414

i)

doz

473

a) PVC pipe dia 20 mm (3/4)

24

b) PVC pipe dia 25 mm (1)

30

c) PVC pipe dia 30 mm (1-1/4)

32

d) PVC pipe dia 40 mm (1-1/2)

39

a) PVC Tee dia 20 mm (3/4)

no

10

b) PVC Tee dia 25 mm (1)

no

12

c) PVC Tee dia 30 mm (1-1/4)

no

16

d) PVC Tee dia 40 mm (1-1/2)

no

19

a) PVC elbow dia 20 mm (3/4)

no

10

b) PVC elbow dia 25 mm (1)

no

12

c) PVC elbow dia 30 mm (1-1/4)

no

16

d) PVC elbow dia 40 mm (1-1/2)

no

19

a) PVC socket dia 20 mm (3/4)

no

b) PVC socket dia 25 mm (1)

no

c) PVC socket dia 30 mm (1-1/4)

no

10

d) PVC socket dia 40 mm (1-1/2)

no

12

a) PVC bend dia 20 mm (3/4)

no

10

b) PVC bend dia 25 mm (1)

no

12

c) PVC bend dia 30 mm (1-1/4)

no

16

d) PVC bend dia 40 mm (1-1/2)

no

20

G.I union size 80 mm (3)

Flanges size 100 mm (4)


PVC PIPES AND FITTINGS

27.

28.

29.

30.

31.

WAPDA

23-6

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1
32.

Description

Unit

Jointing solution

Rate
(Rs.)
4

kg.

410

a) H.D.B. copper wire 2 mm sq. (No. 16 SWG)

b) H.D.B. copper wire 3.2 mm sq. (No. 14 SWG)

c) H.D.B. copper wire 5.4 mm sq. (No. 12 SWG)

16

d) H.D.B. copper wire 8.7 mm sq. (No. 10 SWG)

20

e) H.D.B. copper wire 13 mm sq. (No. 8 SWG)

24

f)

H.D.B. copper wire 19 mm sq. (No. 6 SWG)

41

g) H.D.B. copper wire 27 mm sq. (No. 4 SWG)

49

h) H.D.B. copper wire 32 mm sq. (No. 3 SWG)

57

i)

H.D.B. copper wire 38.6 mm sq. (No. 2 SWG)

68

j)

H.D.B. copper wire 45.6 mm sq. (No. 1 SWG)

96

k) H.D.B. copper wire 53 mm sq. (No. 1/10 SWG)

113

l)

H.D.B. copper wire 61 mm sq. (No.2/0 SWG)

130

m) H.D.B. copper wire 70 mm sq. (No. 3/0 SWG)

151

a) Switch one way S.P. 5 amps

each

20

b) Switch two way S.P. 5 amps

each

24

c) Switch one way S.P. 10/15 amps

each

30

a) Switch one way S.P. 5 amps

each

16

b) Switch two way S.P. 5 amps

each

22

c) Switch one way S.P. 15 amps

each

30

a) 2 Pin 5 amps plug and sockets

each

18

b) 3 Pin 5 amps plug and sockets

each

20

c) 3 Pin 10/15 amps plug and sockets

each

30

a) Bakelite ceiling rose with two terminals

each

24

b) Bakelite ceiling rose with two terminals

each

28

a) Brass pendent lamp holder

each

30

b) Brass pendent lamp holder, screw type

each

26

39.

a) Brass batten holder

each

24

each
each

24

40.

b) Brass batten holder angle type


Backelite Lamp Holder Pendent

HARD DRAWN BARE COPPER WIRE


33.

ELECTRICAL ACCESSORIES
Surface Type Switches
34.

Flush Type Switches (Piano)


35.

Plugs and Sockets Surface Type


36.

Ceiling Rose
37.

Bakelite Lamp Holder Bayonet Cap Type


38.

WAPDA

23-7

14
WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1

Description

Unit

Rate
(Rs.)
4

41.

Batten holder angle

each

13

42.

E.T. shade 254 mm (10) dia

each

53

43.

Plastic shade 254 mm (10 ) dia

each

20

44.

Brass bracket 228 mm (9) dia size heavy gauge

each

65

a) Switch A.C. one way S.P. 5 amps with side operating


fixed handle

each

138

b) Switch A.C. two way S.P. 5 amps with side operating


fixed handle

each

167

c) Switch A.C. one way S.P. 15 amps with side operating


fixed handle

each

276

a) 3 Pin 5 amps plug and socket

each

197

b) 3 Pin 15 amps plug and socket

each

276

c) 3 Pin 5 amps plug and socket with switch in one case

each

118

d) 3 Pin 15 amps plug and socket with switch in one case

each

167

e) 3 Pin 15 amps plug and socket with ICDP control with


side operating handle cable entries with lamp S.P. fuse.

each

177

a) D.P. change over switch (15 amps)

each

548

b) D.P. change over switch (30 amps)

each

887

c) D.P. change over switch (60 amps)

each

1,192

a) T.P. & N change over switch (15 amps)

each

1,163

b) T.P. & N change over switch (30 amps)

each

1,537

c) T.P. & N change over switch (60 amps)

each

1,833

d) T.P. & N change over switch (100 amps)

each

6,680

e) T.P. & N change over switch (200 amps)

each

11,823

f)

each

14,404

a) 100 amps bus bar chamber 0.6 m (2 ft) long 2 strips

each

1,783

b) 100 amps bus bar chamber 1.37 m (4.5 ft) long 2 strips

each

3,310

c) 100 amps bus bar chamber 1.82 m (6 ft) long 2 strips

each

5,636

d) 100 amps bus bar chamber 0.6 m (2 ft) long 3 strips

each

3,153

e) 100 amps bus bar chamber 1.37 m (4.5 ft) long 3 strips

each

6,660

f)

each

7,685

g) 100 amps bus bar chamber 0.6 m (2 ft) long 4 strips

each

3,547

h) 100 amps bus bar chamber 1.37 m (4.5 ft) long 4 strips

each

7,685

i)

each

11,429

Weather Proof Switches in c/l Case


45.

Weather Proof and Cast iron Case


46.

Change Over Switches


47.

48.

T.P. & N change over switch (300 amps)

Bus Bar Chamber


49.

WAPDA

100 amps bus bar chamber 1.82 m (6 ft) long 3 strips

100 amps bus bar chamber 1.82 m (6 ft) long 4 strips


23-8

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1
50.

51.

52.

53.

WAPDA

Description

Unit

Rate
(Rs.)
4

a) 200 amps bus bar chamber 0.6 m (2 ft) long 2 strips

each

2,759

b) 200 amps bus bar chamber 0.91 m (3 ft) long 2 strips

each

5,636

c) 200 amps bus bar chamber 1.82 m (6 ft) long 3 strips

each

11,271

d) 200 amps bus bar chamber 0.6 m (2 ft) long 3 strips

each

5,123

e) 200 amps bus bar chamber 0.91 m (3 ft) long 3 strips

each

7,685

f)

each

15,370

g) 200 amps bus bar chamber 0.6 m (2 ft) long 4 strips

each

5,912

h) 200 amps bus bar chamber 0.91 m (3 ft) long 4 strips

each

8,769

i)

200 amps bus bar chamber 1.37 m (4.5 ft) long 4 strips

each

13,005

j)

200 amps bus bar chamber 1.82 m (6.5 ft) long 4 strips

each

17,341

k) 300 amps bus bar chamber 0.91 m (3 ft) long 2 strips

each

3,251

l)

each

8,079

m) 300 amps bus bar chamber 0.6 m (2 ft) long 4 strips

each

6,503

n) 300 amps bus bar chamber 0.91 m (3 ft) long 4 strips

each

9,951

o) 300 amps bus bar chamber 1.37 m (4.5 ft) long 4 strips

each

13,794

p) 300 amps bus bar chamber 1.82 m (6 ft) long 2 strips

each

1,986

q) 300 amps bus bar chamber 0.6 m (2 ft) long 4 strips

each

7,685

r) 500 amps bus bar chamber 1.37 m (4.5 ft) long 2 strips

each

16,365

s) 500 amps bus bar chamber 1.82 m (6 ft) long 3 strips

each

27,587

t)

300 amps bus bar chamber 0.6 m (2 ft) long 3 strips

each

10,247

u) 500 amps bus bar chamber 1.37 m (4.5 ft) long 3 strips

each

26,602

v) 500 amps bus bar chamber 1.82 m (6 ft) long 4 strips

each

43,351

w) 300 amps bus bar chamber 0.6 m (2 ft) long 4 strips

each

15,764

x) 500 amps bus bar chamber 0.91 m (3 ft) long 4 strips

each

2,168

y) 500 amps bus bar chamber 1.37 m (4 ft) long 4 strips


ELECTRICAL BELLS AND BUZZERS

each

32,513

a) Electrical bell 70 mm (2.5) gong

each

83

b) Buzzer (Electric)

each

41

c) W.P. Electrical bell 100 mm (4) gong

each

577

d) W.P. Electric bell 150 mm (6) gong

each

867

BUSH BUTTONS
a) Piano type wall push button

each

24

b) Flush type push button

each

24

c) Table push button

each

26

EXHUAST FANS
a) ACS P Exhaust fan Plastic body 6

each

1,015

b) ACSP exhaust fan 228 mm (8) sweep complete

each

1,379

each

1,419

200 amps bus bar chamber 1.82 m (5 ft) long 3 strips

300 amps bus bar chamber 0.91 m (3 ft) long 3 strips

c) ACSP exhaust fan 228 mm (10) sweep complete with


regulator
23-9

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1

Unit

d) ACSP exhaust fan 305 mm (12) sweep complete with


regulator

each

1,892

e) ACSP exhaust fan 380 mm (16) sweep complete with


regulator

each

2,404

ACSP exhaust fan 457 mm (18) sweep complete with


regulator

each

4,138

g) ACSP exhaust fan with plastic blade A.C. sweep (8)


200 volt

each

1,596

h) ACSP exhaust fan with plastic blade A.C. sweep (10)


200 volt

each

1,695

a) Bracket fan with plastic moveable loovers (12)

each

1,911

b) Bracket fan with plastic moveable loovers (16/18)

each

2,365

c) Butterfly shutter for 305 mm (12) exhaust fan

each

49

d) Butterfly shutter for 380 mm (15) exhaust fan

each

55

e) Butterfly shutter for 457 mm (18) exhaust fan

each

89

f)

54.

Rate
(Rs.)
4

Description

WOODEN MATERIAL
55.

Rawal plug

each

56.

Wooden/Rubber bush

each

a) Brass screws 12.7 mm (1/2)

each

0.51

b) Brass screws 19.1 mm (3/4)

each

0.59

c) Brass screws 25.4 mm (1)

each

0.69

d) Brass screws 31.7 mm (1-1/4)

each

1.18

e) Brass screws 38.0 mm (1-1/2)

each

f)

each

each

a) Tinned clip size 38.0 mm (1-1/2)

100 nos

10

b) Tinned clip size 44.4 mm (1-3/4)

100 nos

11

c) Tinned clip size 50.8 mm (2)

100 nos

12

d) Tinned clip size 57.2 mm (2-1/4)

100 nos

13

e) Tinned clip size 63.5 mm (2-1/2)

100 nos

14

a) Bolts and nuts size 7.90 mm (5/16)

each

12

b) Bolts and nuts size 9.55 mm (3/8)

each

16

c) Bolts and nuts size 12.7 mm (1/2)

each

18

d) Bolts and nuts size 15.8 mm (5/8)

each

22

e) Bolts and nuts size 19.1 mm (3/4)

each

28

TINNED SCREWS
57.

Brass screws 44.4 mm (1-3/4)

g) Brass screws 50.8 mm (2)


TINNED STRAP CLIPS
58.

BOLTS AND NUTS


59.

WAPDA

23-10

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1

Description

Unit

Rate
(Rs.)
4

SHEETS
60.

a) Masonite sheet

sqm

1,596

b) Plastic sheet

sqm

1,438

c) Tufnol sheet

sqm

2,522

d) Delaron sheet

sqm

3,153

OVERHEAD TRANSMISSION AND DISTRIBUTION


61.

i.

Channel iron (3x1.5x1.5x1/4) 76x38x38x6.3 mm

355

ii.

Channel iron (4x2x2x1/2) 101x50x60x6.3 mm

512

i.

Flat iron (2x3/8) 50.8x9.5 mm

71

ii.

Flat iron (3x3/8)76.2 x 9.5 mm

158

a) Galvanized M.S. flat (1.5x3/16) 38 x 4.7 mm

75

b) Galvanized M.S. flat (1.75x1/4) 44 x 6.3 mm

118

c) Galvanized M.S. flat (1.5x3/16) 38 x 4.7 mm

83

d) Galvanized M.S. flat (1x3/16) 25.4 x 4.7 mm

71

e) Galvanized M.S. flat (2x1/4) 50 x 6.3 mm

130

a) Angle iron (2x2x1/4)50x50x6.3 m

256

b) a) Angle iron (2.5x2.5x1/4)63x63x6.3 m

296

a) M.S. bolts with nuts (3x3/8)76.0x9.5 mm

each

b) M.S. bolts with nuts (4.5x0.5)114x12.7 mm

each

18

c) M.S. bolts with nuts (4x0.5)101x12.7 mm

each

16

d) M.S. bolts with nuts (4x1.5)101x38 mm

each

51

G.I. bolts with (4x5/8)101x15.8 mm

each

26

G.I. bolts with pin type insulator

each

26

a) Shackle insulator medium pressure (2.5x2)63x50 mm

each

20

b) Shackle insulator medium pressure (3.5x3)89x76 mm

each

26

68.

Pin type insulator medium pressure

each

32

69.

Robin Reel

each

16

70.

a) Aerial service fuse with 10/15 amps fuse carrier

each

18

b) Aerial service fuse with (30 amps) fuse carrier withdrawable

each

51

c) Aerial service fuse with (60 amps) fuse carrier with


drawable

each

63

d) Aerial service fuse strip type 10/15 amps

each

43

71.

Lighting arrestor horn type

each

3,251

72.

G.I. eye holt with nut (4x5/8) 101 x 15.8 mm

each

24

73.

G.I. Thimble

each

30

74.

a) G.I. stay wire (7/8) size 22.2 mm

71

b) G.I. stay wire (7/10) size 17.7 mm

81

62.
63.

64.
65.

66.
67.

WAPDA

23-11

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
7
75.
76.

77.

Description

Unit

Rate
(Rs.)
4

c) G.I. stay wire (7/14) size 12.7 mm

91

a) Rail 132.6 Kg per metre (90 lbs per foot)

3,941

b) Rail 88.4 kg. Per metre (60 lbs per foot)

2,365

a) Stay swivel (14x1.5) 355 x 38 mm

each

187

b) Stay rod 1.82 Mt. X 19.0 mm (6x3/4) with base plate


c) Stay rod 1.82 Mt. X 9.5 mm (6x3/8) with base plate

each
each

512

a) G.I. strips 2x152x33.3 x 1.5 mm (2x6x1-5/16x1/16) with


bolts and nuts

each

167

b) G.I. strips 2x190x38 x 3.1mm (2x7.5x1.5x1/8) with


bolts and nuts

each

217

a) M.S. bolts with double nuts 76x9.5 mm (3x3/8)

39

b) M.S. bolts with double nuts 76x12.7 mm (3x1/2)

47

c) M.S. bolts with double nuts 181x15.8 mm (4x5/8)

55

d) M.S. bolts with double nuts 355x15.8 mm (14x5/8)

148

a) Angle iron 38x38x6.3 mm (1.5x1.5x1/4)

386

b) Angle iron 50x50x8.3 mm (2x2x1/4)

404

M.S. round bar 15.8 mm (5/8 dia)

122

a) White opel glass globe 150 mm (6)

each

217

b) White opel glass globe 200 mm (8)

each

246

512

BOARDS FITTINGS AND FIXTURES U.G. CABLE AND


EARTHING
Boards
78.

79.
80.

Fitting and Fixture


81.

UNDER GROUND CABLE


82.

Empire tape 19 mm (3/4)

roll

217

83.

Tin ingot

roll

1,025

84.

Kointing ferruls

set

138

85.

Cable compound

kg

128

a) Copper plate 50x50x3.1 mm (2x2x1/8)

kgs

296

b) Copper bolts with nut washers 12.70 x 76 mm (1/2x3)

each

69

87.

G.I. Plate (2x2x1/4) or 50x50x6.3 mm

kgs.

12

88.

Charcoal dust

kgs.

20

89.

G.I. Plate (2x2x1/4) or 50x50x6.3 mm

kgs.

116

90.

G.I. bolts with nuts and washer 76 x 15.8 mm (3x5/8)

each

30

91.

0.91 m (3 ft.) lighting copper rod with 5 spikes and ball etc.
complete

each

1,971

92.

Copper tape (1.5 x 1/8) size 38 x 3.1 mm

93.

Saddles with fixing material

Earthing
86.

WAPDA

23-12

kg.

276

each

39
WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1

Description

Unit

Rate
(Rs.)
4

WATER PUMPS
94.

a) M.S. bolts with nuts 228 mm long with steel base plate

each

118

b) M.S. bolts with nuts 304 mm long x 38 mm with steel


base plate

each

414

c) M.S. bolts with nuts 457 mm long x (18) long with steel
base plate

each

532

a) Pressure gauge 114 mm (4.5) dia

each

640

b) Pressure gauge 152 mm (6) dia

each

828

a) Star delta motor starter 7/15 amps manual operated

each

1,409

b) Star delta motor starter 12/25 amps manual operated

each

3,035

c) Star delta motor starter 7/15 amps automatic

each

5,320

d) Star delta motor starter 12/25 amps automatic

each

7,291

a) Direct on starter upto 4/8 amps

each

2,207

b) Direct on starter upto 7/15 amps

each

828

a) 36 sweep Best Quality Pak Made

each

2,562

b) 48 sweep Best Quality Pak Made

each

2,857

c) 56 sweep Best Quality Pak Made

each

2,956

each

2,365

a) Electric choke ECCO /EKKO 40 W

each

195

b) Electric choke ECCO /EKKO 20 W

each

152

Pkt of 25
pieces

281

b) Tube holder

doz.

197

c) Tube holder AlWIS TYPE

pair

59

102.

Lamp holder brass screw for 500/100 w lamp type

each

59

103.

a) Halogen tublar lamp 500 w (China)

each

158

b) Halogen tublar lamps 1000 w (China)

each

177

104.

Switch socket 20 amps with porceline base PPI

each

591

105.

Switch socket flat type 13 amp imported

each

236

106.

Shoe 13 Amp. Flat pin type imported

each

99

107.

Switch socket 2 pin with earth-link & box imported

each

1,084

108.

Circuit breaker shoe type 16 Amp Busch

each

985

109.

Switch socket 16 amp Busch

each

236

110.

a) Circuit breaker 2 Amp shoe type Busch

each

1,094

95.
96.

97.

CEILING AND BRACKET FANS


Ceiling Fan
98.

Bracket Fan
99.

(a) 18 sweep Best Quality Pak Made


ADDITIONAL ELECTRICAL ITEMS

100.
101.

WAPDA

a) Tube starter 20/40 W

23-13

WCSR-2013 (Zone-2)

SECTION 23 BASIC RATES OF MATERIAL FOR ELECTRICAL WORKS

Sr.
No.
1

Description

Unit

Rate
(Rs.)
4

b) Circuit breaker 2 Amp shoe type AEG

each

1,025

c) Circuit breaker 15 Amp with porceline Base

each

680

d) Circuit breaker 2 Amp with porceline Base

each

729

111.

Bell Ding Dong

each

128

112.

Bell Electronic Remote Control

each

522

113.

a) Pignum wire Ghazilex No. 34 SWG

kg

729

b) Pignum wire Ghazilex No.36 SWG

kg.

788

114.

Cotton Tape roll

doz

189

115.

a) Leatherrite Paper (China)

kg.

473

b) Leatherrite Paper (Italy)

kg.

528

116.

V.D. Paper

kg.

985

117.

Varnish (Insulations)SAMAKA

litre

79

118.

Fan Hook in M.S. Box (Circular)

no.

177

119.

Dimmer for Fan

no.

118

120.

a) Patti fitting 24 SWG M.S Sheet Painted with white stone


enameled paint complete with choke ECCO/EKKO 40 w
holder and tube light 40w.

no.

414

b) Patti fitting 24 SWG M.S Sheet Painted with white stone


enameled paint complete with choke ECCO/EKKO 20 w
holder and tube light 20w .

no.

335

a) Masonry Drill 7mm () Pak

doz.

154

b) Masonry Drill 13mm () Pak

each

218

c) Masonry Drill 25mm (1) Pak

each

522

a) Capacitor 2.2 MFD Pak

each

35

b) Capacitor 2.5 MFD Pak

each

47

c) Capacitor 3 MFD Pak

each

57

d) Capacitor 4.5 MFD Pak

each

69

e) Capacitor HP Motor (China)

each

91

f)

Capacitor 1 HP Motor (China)

each

150

g) Capacitor 1 HP Motor (China)

each

30

a) Rawal Belt 3/8 Pak

each

30

b) Rawal Belt Pak

each

49

121.

122.

123.

WAPDA

23-14

WCSR-2013 (Zone-2)

SECTION 24 BASIC RATES OF LABOUR

SECTION-24

BASIC RATES OF LABOUR

WAPDA

Sr.
No.

Trade

Unit

Rate (Rs.)

1
2

Armature Winder
Belcha man

No
No

441

Belder

No

401

4
5

Bellows man
Blacksmith

No
No

401

Boatman

No

481

Boiler Foreman

No

562

8
9

Bullockman
Bullockman 1/2 pair

No
No

441
401

10

Cable Jointer

No

562

11

Caner

No

441

12
13

Carpenter 2nd Class


Carpenter Ist Class

No
No

401

14

Carrier

No

401

15

Cart man (with cart)

No

642

16
17

Chakriman
Chiseller

No
No

401
646

18

Chowkidar

No

401

19

Cleaner

No

401

20
21

Compressor operator
Concrete Lining Machine Operator

No
No

646
802

22

Crane Driver/Operator

No

562

23

Diesel Engine Mechanic

No

562

24
25

Diesel Engine Operator Grade-I


Diesel Engine Operator Grade-II

No
No

646
401

26

Digger

No

401

27
28

Diver (Deep Water)


Diver (Shallow Water)

No
No

562

29

Dolley man

No

401

30

Dozer Operator

No

562

31
32

Dresser
Driller

No
No

584
562

33

Driver (Sheep Foot Roller)

No

661

34

Driver (Sheep Foot Roller)

No

661

35

Driver (Tractor)

No

36

Electrician

No

646
640

37

Fitter

No

646

38

Fitter (Electrical)

No

481

39

Foreman (Civil)

No

720

24-1

401

680

720

441

WCSR-2013 (Zone-2)

SECTION 24 BASIC RATES OF LABOUR

Sr.
No.

Trade

Unit

Rate (Rs.)

40
41

Foreman (Electrical)
Glazier

No
No

680

42
43

Greaser
Gutti Man

No
No

441
401

44

Hammer Man

No

646

45

Heavy Duty Driver

No

646

46
47

Helper
Light Duty Driver

No
No

440
646

48

Lineman

No

646

49

Machine Mistry

No

521

50
51

Mali
Mason

No
No

441
752

52

Mate

No

481

53

Mechanic

No

521

54
55

Meter Reader
Operator (well sinking)

No
No

441
481

56

Painter

No

640

57

Plumber

No

720

58
59

Polisher
Quarry man

No
No

592
441

60

Rammer

No

401

61
62

Sawyer
Skilled Labour

No
No

441
646

63

Smithy cooly

No

441

64

Spray Man

No

441

65
66

Sprayman Helper
Supervisor

No
No

401
562

67

Surveyor

No

481

68

Switchboard Attendant

No

481

69
70

Tailor
Tiles Layer

No
No

481

71

Trailer Driver

No

562

72

Unskilled Labour/Cooly

No

480

73
74

Water man
Welder Grade-I

No
No

480
640

75

Welder Grade-II

No

441

76

Well Borer

No

441

77

Wireman

No

78

Work Mistry

No

441
481

441

481

Note:
These Rates are hiring charges of Man-power/Labour, per day and one working day is based
on eight (8) hours
WAPDA

24-2

WCSR-2013 (Zone-2)

SECTION 25 BASIC RATES OF MACHINERY USAGE

SECTION-25

BASIC RATES OF MACHINERY USAGE


Sr.
No.
1

Machinery

Unit

Rate (Rs.)

Asphalt Plant Capacity 20 Ton

hour

10,019

Asphalt Plant Capacity 80 Ton

hour

11,363

3.

Assembling Bench for Prestressed Girder

job

9,900

4.

Beading Machine

hour

364

5.

Boring with Rig (12-14)

hour

463

6.

Bull Dozer 90 HP

hour

1,450

7.

Bull Dozer 120 HP

hour

1,865

8.

Cable Forms for Prestressed Girder

9.

job

319

Compressor Capacity 300 CFM

hour

650

10.

Concrete Batching Plant Capacity 30 cum

hour

3,450

11.

Concrete Batching Plant Capacity 50 cum

hour

5,750

12.

Concrete Lining Machine

hour

2,277

13.

Concrete Static mixer 0.2 cum capacity

hour

390

14.

Concrete Static mixer 0.4 cum capacity

hour

515

15.

Concrete Pump 45 cum

hour

2,190

16.

Concrete Transit mixer 4 cum capacity

hour

1,913

17.

Concrete Transit mixer 6 cum capacity

hour

2,318

18.

Concrete vibrator (160cc)

hour

342

19.

Cone Fixer for Prestressed Girder

job

51,615

20.

Densotaps for Prestressed Girder

job

284

21.

Donkey pump with motor 4" delivery (Diesel)

hour

341

22.

Dredger/Motor Scraper/Crane (with bucket & boom)

hour

6,750

23.

Drilling bore hole 1200 mm dia including concreting


with tremmie pipe per meter

job

24.

Drilling bore hole 1600 mm dia including concreting


with tremmie pipe per meter

job

25.

Drilling bore hole 1705 mm dia including concreting


with tremmie pipe per meter

job

26.

Drilling bore hole 457 mm dia including concreting with


tremmie pipe per meter

job

27.

Drilling bore hole 610 mm dia including concreting with


tremmie pipe per meter

job

28.

Drilling bore hole 914 mm dia including concreting with


tremmie pipe per meter

job

29.

Drilling Machine 457 mm dia or above

hour

875

30.

Dumper 10 Ton Capacity

hour

1,540

31.

Dumper 18 Ton Capacity

hour

1,775

32.

Educator Pipe

hour

38

WAPDA

25-1

2,742
3,200
3,279
1,385
1,584
2,513

WCSR-2013 (Zone-2)

SECTION 25 BASIC RATES OF MACHINERY USAGE

Sr.
No.

Machinery

Unit

Rate (Rs.)

33.

Excavator Chain Type

hour

1,780

34.

Excavator (Ex 200)

hour

2,117

35.

Excavator Tire Type

hour

1,805

36.

Front End Loader 1.5 cum

hour

2,400

37.

Front End Loader 2.5 cum

hour

2,813

38.

Front End Loader 3.0 cum

hour

3,900

39.

Grader 140 HP

hour

1,955

40.

Grader 165 HP

hour

2,811

41.

Grouting Pump for Prestressed Girder

job

22,772

42.

Heavy compactor roller

hour

2,250

43.

Hoses for Prestressed Girder

job

4,554

44.

Hydraulic pump for Prestressed Girder

job

154,846

45.

Lifting Tackle for jack for Prestressed Girder

job

103,231

46.

Mechanical rammer / compactor for sloping portion

hour

375

47.

Mixer (road material)

hour

835

48.

Mobile Crane 3 Ton

hour

815

49.

Mobile Crane 10 Ton

hour

1,491

50.

Molding machine

hour

825

51.

Paint Spray Machine

hour

45

52.

Pneumatic Roller 18 Ton Capacity

hour

1,903

53.

Power Generator 150 KVA

hour

2,270

54.

Pump for Dewatering with delivery pipe 4" dia (Diesel)

hour

260

55.

Rail Track for Prestressed Girder

job

56.

Road Roller Tandem 10-12 Ton

hour

1,988

57.

Road Roller Tandem Vibratory 1.5 Ton

hour

425

58.

Road Roller Tandem Vibratory 6 Ton

hour

865

59.

Road Roller Tandem Vibratory 8 Ton

hour

1,160

60.

Road Roller Vibratory & Static Roller 10-12 Ton

hour

1,645

61.

Saw / Wood Cutter Machine (Petrol) 45 cc

hour

625

62.

Sheep Foot Roller

hour

868

63.

Steel Plate Cutter

hour

85

64.

Steel Bar Cutting Machine

hour

75

65.

Steel Bar Bending Machine

hour

55

66.

Stressing jack for Prestressed Girder

67.

Tar Boiler

hour

911

68.

Tractor 50 HP Capacity

hour

400

69.

Tractor with Trolley

hour

442

70.

Tripod & Chain Pulley

hour

170

71.

Trolleys for Prestressed Girder

WAPDA

job

job
25-2

531,335

206,462

75,905
WCSR-2013 (Zone-2)

SECTION 25 BASIC RATES OF MACHINERY USAGE

Sr.
No.

Machinery

Unit

Rate (Rs.)

72.

Truck (5 Ton capacity)

hour

700

73.

Truck (8 Ton capacity)

hour

1,555

74.

Turbine pump

hour

455

75.

Water Bouzer (Capacity 10,000 Ltrs)

hour

509

76.

Water carrier tanker (Capacity 4000 Ltrs)

hour

482

77.

Water sprinkler

hour

531

78.

Welding unit & Generator

hour

284

79.

Well Sinking Machine

hour

1,214

80.

Wheel barrow

hour

228

81.

Wire Cutter for Prestressed Girder

WAPDA

25-3

job

2,277

WCSR-2013 (Zone-2)