Вы находитесь на странице: 1из 31

1

3D TRASAR Technology for


Membranes
3DTfM
Indonesia Customer Seminar
June 13 & 14 2012
Jakarta Indonesia

Water Technology Company of the Year 2012

Nalco, an Ecolab company, was named the 2012 Water


Technology Company by Global Water Intelligence - for the
company which has made the most significant contribution in the
field of water technology over the past year.

The award, given for Nalco's contributions in the field of water


technology, was presented during the 2012 Global Water Awards
ceremony in Rome.

Nalco was recognized for its integrated water technology solutions


platform and the automation and control capabilities it offers
customers, including:
3D TRASAR Membrane Technology as a key expansion of the 3D TRASAR
cooling and boiler automation programs
Nalco 360 Service provides expert monitoring of customer water systems and
identifies potential causes of system variability and abnormal operating
conditions

Critical Factor in Reverse Osmosis Membrane

Pre-Treatment

RO system Design

Monitoring &
Control

RO
Performance

Chemical
Treatment

Damage

P exceeded!

Here is a membrane that was exposed to extremely high


differential pressures due to excessive bio-fouling. Proper
monitoring & control would have prevented this!

P exceeded!

Bio-Fouling!

Scaling

Fouling

Why Is Monitoring & Control Important?

Put very simply


Because it costs money

TCO
Communicate

10

Why Is Monitoring & Control Important?


PT. XYZ
Train

Vessel/Train Membrane/Vessel Total Membrane Price/Membrane

Cost

SWRO

11

132

13,500,000

1,782,000,000

BWRO

56

10,000,000

560,000,000

11

You NEVER want to STOP!


It looks OK
to me

Are you confident that your RO


system is being correctly
treated?
Under varying plant
conditions?

12

RO system management

13

RO system management
No personnel
available

Poor data
collection &
analysis

No time
available

Nalco Solutions!! Integrated MEMBRANE solutions

Chemicals

PermaFloc
Filter Aid for Reducing SDI
Compatible with Treatment Programs
and Membranes

14

Cl2 Scavenger
ORP Monitoring & Control
Prevent RO Oxidation Damage

Automations

3DT for Membranes

PermaTreat

Membrane Performance Management

Antiscalant Programs prevent scaling and assist


in maintaining membrane performance
100% Traced Product Line
Online monitoring & Control

Chemical + Automation + Services + N360

Online / Offline Biocides

CIP

Biocide Programs minimize fouling


due to microbiological growth

PermaClean
Comprehensive line of membrane cleaners
designed to restore membrane performance
due to fouling

Services

Equipment
Membrane Services

Routine system check up


On site membrane cleaning
Offline cleaning
Membrane autopsy
Expert onsite auditing

Nalco N360
Expert Centre

15

Nalco Solutions!!
3D TRASAR Technology for Membranes
Online Monitoring
& Control

System Optimization

Membrane Performance Management

N360 24/7

16

Nalco Solutions!!
Drive performance towards Best Practices

Real time control and monitoring


Immediate feedback on problems
Improve chemical control
Reduce risk for chlorine exposure
Minimize risk of membrane scaling
Safely operate at optimal recovery
Minimize plant labor requirements
Verify membrane integrity
Cleaning at the right time

17

Right Anti-Scalant, Product Selected

18

Anti-Scalant Dosage

Concentration

Over feed = fouling

Target Dose

Under feed = scale

19

Anti-Scalant Dosage

20

Right Dosage

21

Cleaning at The Right Time

22

RO system chemical control

Are you facing the same dosing problem

23

3DT for Membrane


Cartridge Filter

RO
Permeate

Feed
HP

Antiscalant
Sodium Bisulfite

PID Pump

3DTfM

Chemical real-time monitoring & control


System performance monitoring and optimization

24

Membrane Automation - 3DT for Membrane

Chemicals Control + Monitoring + Alerting

25

On-line Anti-Scalant Monitoring & Control

26

Chlorine Surge Protection

Chlorine damage is a common reason for low


performing membranes and premature membrane
replacement.
A new Best Practice approach to prevent chlorine
from damaging RO membranes is to employ 3D
TRASAR Membrane Technology with its built-in
Chlorine Surge Protection (CSP).
3DTfM with Chlorine Surge Protection uses a
fixed SBS dosage rate with an override feature
that will increase SBS dosage only after a
prescribed ORP high limit is detected.
This strategy delivers the needed amount of SBS
to quickly arrest chlorine excursions as shown in
the figure.

27

RO data collection & Trending

Data
Download

All Coming into 3DTfM

Feed/Concentrate/Permeate Flow

Feed/Permeate Conductivity & Temperature

Feed/Inter-stage/Concentrate/Permeate Pressures

Trending &
Analysis

Permeate
Feed Water
Concentrate

28

3DT for Membrane Skid

29

In Summary..We Are Heading Toward


Concentrate

Permeate
Feed Water

2011/12
No Control

RO Trasar
3DT for Membranes

No Performance Assurance
No online monitoring & control

Limited Performance Assurance

Proactive Membrane Performance Management

Online monitoring & control of antiscalant


Ensure accurate antiscalant dosage at all times
ORP & temperature monitoring

Online monitoring & control of antiscalant


Ensure accurate antiscalant dosage at all times
RO system parameter normalization & trending
Service Report available via web

30

Nalco RO Treatment Reference Power Industry

31

Thank You..

Вам также может понравиться