Вы находитесь на странице: 1из 16

Metal, types XCKM, XCKL and XCKML

561644

v With head for linear movement


(plunger)

with 3 cable entries

561643

OsiSense XC Standard, Classic format

v With head for rotary movement


(lever) or multi-directional
561645

b XCKM,

Limit switches

808148

Presentation,
general characteristics

2
Page 1/76

v With head for rotary movement


(lever) or multi-directional
808147

808145

v With head for linear movement


(plunger)

808141

b XCKL,
with 1 cable entry

808140

3
4

v With head for rotary movement


(lever)
561642

v With head for linear movement


(plunger)
561639

with 3 cable entries and 2 x 2-pole contacts

561641

b XCKML,

561640

Page 1/78

6
7

Page 1/80

Environment characteristics
Conformity to standards

8
9

Product certifications
Protective treatment
Ambient air temperature
Vibration resistance
Shock resistance
Electric shock protection
Degree of protection
Repeat accuracy
Cable entry or connector
Materials

10

1/74

Products
Machine assemblies
Version
For operation
For storage
Conforming to IEC 60068-2-6
Conforming to IEC 60068-2-27

Depending on model

IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n 14


IEC 60204-1, EN 60204-1
UL, CSA, CCC (only for XCK M)
Standard: TC. Special: TH
- 25+ 70C
- 40+ 70C
25 gn (10500 Hz)
50 gn (11 ms)
Class I conforming to IEC 61140 and NF C 20-030
IP 66 conforming to IEC 60529; IK05 conforming to EN 50102
XCKML 0.1 mm; XCKM and XCKL 0.05 mm on the tripping points, with 1 million operating
cycles for head with end plunger
XCKM: 3 tapped entries for n 11 cable gland or tapped ISOM20, or with 1/2" NPT adaptor
XCKL: 1 tapped entry incorporating cable gland or 1 entry tapped 1/2" NPT
XCKML: 3 tapped entries for n 13 cable gland or tapped ISOM20
Bodies: zamak.
Rotary heads: zamak or plastic, depending on product reference. Other heads: plastic

General characteristics
(continued)

Limit switches

OsiSense XC Standard, Classic format


Metal, types XCKM, XCKL and XCKML

Contact block characteristics

XE2pP
XE3pP

Rated impulse
withstand voltage

XE2pP
XE3pP
Positive operation (depending on model)
Resistance across terminals
Short-circuit
XE2pP
protection
XE3pP
Connection
XE2S P21p1
(screw clamp terminals)
XE2N P21p1
XESP2151L and XENP2151L
XE3NP and XE3SP
Minimum actuation speed
Electrical durability

AC supply
50/60 Hz a
o inductive circuit

Ithe

110 V

0.5

230/400 V

0.1
0.5

DC supply c

24 V

48 V
2

5
4
3

1
0.5

110 V
230/400 V

24 V

3
4

12/24/48 V

110 V

1
0.5

0.1
0.5

3 4 5
10
Current in A

XE3NPpppp
Ithe

Ithe
230 V

Power broken in W for 5 million operating


Power broken in W for 5 million operating
cycles.
cycles.
Voltage
V
24
48
120
Voltage
V
24
48
120
o
o
W
10
7
4
W
13
9
7
For XE2SPp151 on a or c, NC and NO contacts simultaneously loaded to the values shown
with reverse polarity.

0.2

10
3 4 5
Current in A

XE3SPpppp
AC supply
50/60 Hz a
o inductive circuit

Millions of operating cycles

Rated insulation
voltage

Millions of operating cycles

XE3pP

a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A


c DC-13; Q300 (Ue = 250 V, Ie = 0.27 A), conforming to IEC 60947-5-1 Appendix A, EN60947-5-1
a AC-15; B300 (Ue = 240 V, Ie = 1.5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
Ui = 500 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n 14
Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n 14
U imp = 6 kV conforming to IEC 60947-1, IEC 60664
U imp = 4 kV conforming to IEC 60947-1, IEC 60664
NC contacts with positive opening operation conforming to IEC 60947-5-1 Appendix K, EN60947-5-1
y 25 m conforming to IEC 60255-7 category 3
10 A cartridge fuse type gG (gl)
6 A cartridge fuse type gG (gl)
Clamping capacity, min: 1 x 0.34 mm2, max: 2 x 1.5 mm2
Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 2.5 mm2
Clamping capacity, min: 1 x 0.34 mm2, max: 2 x 1.5 mm2 or 1 x 2.5 mm2
Clamping capacity, min: 1 x 0.34 mm2, max: 1 x 1 mm2 or 2 x 0.75 mm2
XE2SP21p1, XESP2151L and XE3SP: 0.01 m/minute
XE2NP21p1, XENP2151L and XE3NP: 6 m/minute
b Conforming to IEC 60947-5-1 Appendix C
b Utilisation categories AC-15 and DC-13
b Maximum operating rate: 3600 operating cycles/hour
b Load factor: 0.5
XE2NP21p1, XENP2151L
XE2SP21p1, XE2SP2141, XESP2151L
Millions of operating cycles

XE2pP

Millions of operating cycles

Rated operational
characteristics

6
7

Ithe

5
4
3
2

230 V
1

12/24/48 V
110 V

0.5
0.2

48 V
0.1

0.5

DC supply c

3 4 5
10
Current in A

Power broken in W for 5 million operating


cycles.
Voltage
V
24
48
120
o
W
3
2
1

0.1
0.5

3 4 5
10
Current in A

Power broken in W for 5 million operating


cycles.
Voltage
V
24
48
120
o
W
4
3
2

10

1/75

Limit switches

References,
characteristics

OsiSense XC Standard, Classic format

Metal, type XCKM


Complete switches with 3 cable entries

Type of head

Plunger (fixing by the body)

Rotary
(fixing by the
body)

Multi-directional,
(fixing by the
body)

Thermoplastic
roller lever (1)

Cats whisker (2)

2
Type of operator

Metal end plunger

XCKM110
13

21
22

2-pole NC + NO
snap action
(XE2SP2151)

XCKM110H29
21-22
13-14
21-22
13-14

4.5(P)

1.8
0

5.5mm

13
14

21
22

21-22
13-14

1.8 3.2(P)
0

ZCKM9H29 +
ZCKD10
1.8

XCKM102

XCKM121

XCKM102H29

XCKM121H29

5.5mm

11

21

12

22

31

21

13

32

22

14

3-pole
NC + NC + NO
snap action
(XE3SP2141)

1.8

5.5mm

ZCKMD39H29 +
ZCKD10
1.8 4.5 (P) mm

5.5

31

21

13

22

14

0.9

3-pole
NC + NC + NO
break before make,
slowbreak
(XE3NP2141)

ZCKMD37H29 +
ZCKD10
21-22
31-32
13-14

Weight (kg)
Contact operation

mm

1.8 3.2 (P) mm


3

0.250
closed
open

5.5

mm

1.5

2.2

XCKM502H29

XCKM521H29

21-22
13-14

3.1(A) 5.6(P)
0

5.2

11-12
21-22
11-12
21-22

21-22
13-14

mm

XCKM115

XCKM106

3.1(A) 7.8(P)
0

7.6 mm

4.6(A) 11.1(P)

11-12
21-22
11-12
21-22

mm

11-12
21-22

5.6(P)

ZCKMD39H29 +
ZCKD02
21-22
31-32
13-14
21-22
31-32
13-14

4.6(A) mm

ZCKMD39H29 +
ZCKD21

3.1 (A) 7.8 (P) mm

21-22
31-32
13-14
21-22
31-32
13-14

4.6 (A) 11.1 (P)mm

ZCKMD37H29 +
ZCKD21

3.1 (A) 3.2 (P) mm


5.2

5.5

21-22
13-14
21-22
13-14

XCKM506H29

XCKM515H29
21-22
13-14

21-22
13-14

ZCKM9H29 +
ZCKD15
11-12
21-22
11-12
21-22

ZCKM9H29 +
ZCK D06
11-12
21-22
11-12
21-22

ZCKM7H29 +
ZCKD15

ZCKM7H29 +
ZCK D06

21-22
31-32
13-14

0.255
0.300
(A) = cam displacement
(P) = positive opening point

11-12
21-22

11-12
21-22

ZCKMD39H29 +
ZCKD15
26 58 (P)

21-22
31-32
13-14
21-22
31-32
13-14

2.2

ZCKMD37H29 +
ZCKD02

21-22
13-14
21-22
13-14

8(P)

11-12
21-22

1.5

21-22
31-32
13-14

mm

2.2

ZCKM7H29 +
ZCKD21

3.1(A) 9mm

XCKM106H29

XCKM115H29

4.6(A) 8(P)

ZCKM9H29 +
ZCKD21

ZCKM7H29 +
ZCKD02

3.2(P)

21-22
31-32
13-14
21-22
31-32
13-14

4.6(A) 11.1(P)

21-22
13-14
21-22
13-14

1.5

ZCKM7H29 +
ZCKD10
11-12
21-22

3.1(A) 7.8(P)

21-22
13-14
21-22
13-14

ZCKM9H29 +
ZCKD02

4.5(P)

5.5mm

0.9

32

XCKM510H29

11-12
21-22
11-12
21-22

2-pole NC + NC
simultaneous,
slowbreak
(XE2NP2141)

11

12

2-pole NC + NC
snap action
(XE2SP2141)

22

2-pole NC + NO
break before make,
slowbreak
(XE2NP2151)

21

0.9

Thermoplastic roller
lever plunger,
horizontal actuation
in 1 direction

References of complete switches with 3 ISO M20 x 1.5 cable entries (3)
14

Steel roller plunger

4.6 (A) 8 (P) mm


7.6

70

11

ZCKMD37H29 +
ZCKD15
21-22
31-32
13-14

26

42 (P)
36

ZCKMD39H29 +
ZCK D06
21-22
31-32
13-14
21-22
31-32
13-14

14

ZCKMD37H29 +
ZCK D06
21-22
31-32
13-14

70

0.280

30

30

40

0.250

NC contact with positive opening operation

References of complete switches with 3 Pg 11 cable entries


For complete switches with 3 Pg 11 cable entries, delete H29 from the end of the reference. Example: XCKM110H29 becomes XCKM110.

Characteristics

Switch actuation
Type of actuation

Maximum actuation speed

10

On end

By 30 cam

0.5 m/s
1.5 m/s
20
15
Mechanical durability (4)
(in millions of operating cycles)
Minimum force For tripping
15 N
12 N
8N
0.1 N.m
or torque
For positive opening
45 N
36 N
24 N
0.25 N.m
Cable entry
3 entries tapped M20 x 1.5 mm for ISO cable gland, clamping capacity 7 to 13 mm
(1) Adjustable throughout 360 in 5 steps, or in 90 steps by reversing the notched washer.
(2) Value taken with actuation by moving part at 100 mm from the fixing.
(3) Switches with gold contacts or eyelet type connections: please consult our Customer Care Centre.
(4) Limited to 15 million operating cycles for switches with contacts XE3pP.

1/76

By any moving part

1 m/s (any direction)


10
0.13 N.m

Limit switches

Dimensions

OsiSense XC Standard, Classic format


Metal, type XCKM
Complete switches with 3 cable entries

XCKMp02
ZCKMD3p + ZCKD02

XCKMp10
ZCKMD3p + ZCKD10

XCKMp21
ZCKMD3p + ZCKD21

14

14

108

88.5
(1)

41

(1)

64

30

41

XCKMp06
ZCKMD3p + ZCKD06

22 15

41

(1)
30

64

30

XCKMp15
ZCKMD3p + ZCKD15

112.5

30

48.5

54

14

11.5

65

Rear view XCKMppp, ZCKMp,


ZCKMD3p

4
5

41

54

119

201

60.5

34.5

142.5

14

5.5

(2)

30
8

(1)

41
64

34

(1)
30

41

27

6
=

64

(1) 3 tapped entries for ISO M20 x 1.5 or Pg 11 cable gland or with 1/2" NPT conduit adaptor DE9RA1012.
(2) 2 x 4 H 11, depth 10.
: 2 elongated holes 5.2 x 6.2

Adaptor for 1/2" NPT conduit


DE9RA1012

(1)

21

(2)

(1) Tapped entry for 1/2" NPT conduit.


(2) Threaded sleeve.

9
10

1/77

Limit switches

References,
characteristics

OsiSense XC Standard, Classic format

Metal, type XCKL


Complete switches incorporating cable gland

Type of head

Plunger (fixing by the body)

Rotary
(fixing by
thebody)

Multi-directional,
(fixing by
thebody)

Thermoplastic
roller lever (1)

Cats whisker (2)

2
Type of operator

Metal end plunger

XCKL110
13

21
22

2-pole NC + NO
snap action
(XE2SP2151)

14

References (3)
4.5(P)

1.8
0

5.5mm

21

13

22

21

14

13

31

22

3-pole
NC + NC + NO
snap action
(XE3SP2141)

32

14

0.9

2-pole NC + NO
break before make,
slowbreak
(XE2NP2151)

5.5mm

ZCKLD39 +
ZCKD10

5.5

11

21

12

22

31

21

13

22

14

3-pole
NC + NC + NO
break before make,
slow break
(XE3NP2141)

10

1.8

21-22
31-32
13-14

0.255
closed
open

Maximum actuation speed

0.5 m/s
20

mm

21-22
13-14
21-22
13-14

21-22
13-14

4.6(A) 11.1(P)
0

21-22
31-32
13-14
21-22
31-32
13-14

5.2

mm

5.5

21-22
13-14

7.6 mm

21-22
31-32
13-14
21-22
31-32
13-14

4.6 (A) 11.1 (P)mm

21-22
31-32
13-14

21-22
13-14

5.6(P)
3.1(A) 9mm

5.2

ZCKL7 + ZCKD21

11-12
21-22

5.5

21-22
31-32
13-14

21-22
13-14

21-22
31-32
13-14
21-22
31-32
13-14

26 58 (P)

70

11

ZCKLD39 +
ZCK D06

ZCKL7+ ZCKD15

21-22
31-32
13-14
21-22
31-32
13-14

30

14

ZCKL7 + ZCKD06

8(P)
4.6(A) mm

ZCKLD37 +
ZCKD21

3.1 (A) 3.2 (P) mm

XCKL506

ZCKLD39 +
ZCKD15

2.2

ZCKL7 + ZCKD02

XCKL515

ZCKLD39 +
ZCKD21

3.1 (A) 7.8 (P) mm

21-22
13-14
21-22
13-14

4.6(A) 8(P)
0

1.5

11-12
21-22

mm

2.2

21-22
13-14
21-22
13-14

XCKL106
XCKL106

XCKL115

XCKL521

3.1(A) 5.6(P)
0

XCKL115

4.6 (A) 8 (P) mm

0.260
0.305
(A) = cam displacement
(P) = positive opening point

7.6

11-12
21-22

11-12
21-22

ZCKLD37 +
ZCKD15
21-22
31-32
13-14

26

0.285

ZCKLD37 +
ZCK D06

42 (P)
36

21-22
31-32
13-14

70

30

40

0.255

NC contact with positive opening operation

By 30 cam

By any moving part

1.5 m/s
15

15 N
12 N
8N
0.1 N.m
45 N
36 N
24 N
0.25 N.m
Cable entry
1 entry incorporating metal cable gland. Clamping capacity 6 to 13.5 mm.
(1) Adjustable throughout 360 in 5 steps, or in 90 steps by reversing the notched washer.
(2) Value taken with actuation by moving part at 100 mm from the fixing.
(3) Switches with gold contacts or eyelet type connections: please consult our Customer Care Centre.
(4) Limited to 15 million operating cycles for switches with contacts XE3pP.

1/78

For tripping
For positive opening

ZCKLD37 +
ZCKD02

1.8 3.2 (P) mm

On end

Minimum force
or torque

5.5mm

ZCKLD37 +
ZCKD10

Switch actuation
Type of actuation

Mechanical durability (4)


(in millions of operating cycles)

3.2(P)

Weight (kg)
Contact operation

Characteristics

ZCKL7 + ZCKD10

11-12
21-22

32

3.1(A) 7.8(P)

ZCKLD39 +
ZCKD02

1.8 4.5 (P) mm

0.9

2-pole NC + NC
simultaneous,
slow break
(XE2NP2141)

XCKL121

XCKL121

XCKL502

1.8 3.2(P)
0

21-22
31-32
13-14
21-22
31-32
13-14

21-22
13-14
21-22
13-14

Thermoplastic roller
lever plunger,
horizontal actuation
in 1 direction

1.5

XCKL510
21-22
13-14

XCKL102
XCKL102

XCKL110
21-22
13-14
21-22
13-14

Steel roller plunger

1 m/s (any direction)


10
0.13 N.m

Limit switches

Dimensions

OsiSense XC Standard, Classic format


Metal, type XCKL
Complete switches incorporating cable gland

XCKLp10
ZCKLp + ZCKD10
ZCKLD3p + ZCKD10

XCKLp02
ZCKL3p + ZCKD02
ZCKLD3p + ZCKD02

XCKLp21
ZCKLp + ZCKD21
ZCKLD3p + ZCKD21

14

14

(1)

41
52

30

(1)

41
52

30

30

22 15

(1)

41

5.5

Body fixings

14

142.5

1.2

30

(1)

34

41
52

(1)
30

41
52

(1)
30

67

72

127.5

209.5

60.5

34.5

59.5

XCKLp06
ZCKLp + ZCKD06
ZCKLD3p + ZCKD06

XCKLp15
ZCKLp + ZCKD15
ZCKLD3p + ZCKD15

121

97

115.5

30

48.5

54

14

41
52

(1) Incorporated cable gland


: 2 elongated holes 5.2 x 6.2

8
9
10

1/79

Limit switches

References,
characteristics

Type of head

OsiSense XC Standard, Classic format


Metal, 2 x 2-pole contacts, type XCKML
Complete switches with 3 cable entries

Plunger (fixing by the body)

Rotary (fixing by the


body)

1
2
Type of operator

13

21
22

14

21
22

13

2 x 2-pole NC + NO
snap action (XESP2151L)

XCKML110H29
21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14

5(P)
A
B

6mm

1.2

21

13

21-22
13-14
21-22
13-14

A
B
3.3 6.6mm

13

21
22

21

13
14

14

XCKML110
21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14

A
B

6mm

mm

5(A) 12.6(P)
A
B

mm

XCKML502H29

XCKML521H29

21-22
13-14
21-22
13-14

3.3(A) 6(P)
A
B
0
mm
6

21-22
13-14
21-22
13-14

6(A) 9.3(P)
A
B
10 mm

21

13

21-22
13-14
21-22
13-14

21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14

XCKML121

4(A) 9(P)
A
B
0

mm

21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14

21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14

A
B

XCKML515H29
21-22
13-14
21-22
13-14

A
B

A
B
3.3 6.6mm

XCKML502
21-22
13-14
21-22
13-14

3.3(A) 6(P)
A
B
0
mm
6

XCKML115

5(A) 12.6(P)
A
B

mm

XCKML521
21-22
13-14
21-22
13-14

22

14

13

21
22

14

10

21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14

XCKML115H29

6(A) 9.3(P)
A
B
10 mm

21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14

A
B

XCKML515
21-22
13-14
21-22
13-14

A
B

Weight (kg)
Contact operation

Characteristics

2 x 2-pole NC + NO
XCKML510
break before make, slow break
(XENP2151L)
2 3.4(P)

4(A) 9(P)

XCKML102

5(P)

1.2

21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14

XCKML121H29

XCKML115

References of complete switches with 3 entries tapped for n 13 cable gland (2)

XCKML102H29

Thermoplastic roller lever (1)

2 x 2-pole NC + NO
snap action (XESP2151L)

22

Thermoplastic roller lever


plunger, horizontal actuation
in1 direction

22

14

21
22

13

2 x 2-pole NC + NO
XCKML510H29
break before make, slow break
(XENP2151L)
2 3.4(P)

14

Steel roller plunger

XCKML121
References of completeXCKML110
switches with 3 ISO XCKML102
M20 x 1.5 cable entries
(2)

14

Metal end plunger

0.400
closed
open

Switch actuation
Type of actuation

On end

Maximum actuation speed


Mechanical durability
Minimum force For tripping
For positive
opening
Cable entry

0.5 m/s
3 million operating cycles
15 N
60 N

0.405
(A) = cam displacement
(P) = positive opening point

0.450

0.430

NC contact with positive opening operation

By 30 cam

1.5 m/s
12 N
50 N

8N
50 N

0.2 N.m
0.5 N.m

3 entries tapped ISO M20 x 1.5, clamping capacity 7 to 13 mm, or 3 entries tapped for n 13 cable gland conforming to
NF C 68-300 (DIN Pg 13.5), clamping capacity 9 to 12 mm.
(1) Adjustable throughout 360 in 5 steps, or in 90 steps by reversing the notched washer.
(2) Switches available with other 2-pole slow break contact blocks: NO + NC make before break, NC + NC simultaneous (with positive opening operation),
NO + NO simultaneous. Please consult our Customer Care Centre.
Note: replacement parts
The heads of limit switches type XCKML are the same as those for types XCKM and XCKL (see heads ZCKD10, ZCKD02, ZCKD21 and ZCKD15
on page 1/82).

1/80

Limit switches

Dimensions

OsiSense XC Standard, Classic format


Metal, 2 x 2-pole contacts, type XCKML
Complete switches with 3 cable entries

XCKML110H29, XCKML510H29, XCKML110,


XCKML510

XCKML102H29, XCKML502H29, XCKML102, XCKML502

14.65
13

81

(2)

(1)
=

(1)

(2)

(1)

26.3

61.5

77

14.65

(1)

(1)

26.3

(1)

61.5

77

15

35.6

2
81

5.5

6.2

123.2

6.5

6.2

105

5.5

54.5

35
11.5

6.5

11.5

10

14.65

35.6

XCKML121H29, XCKML521H29, XCKML121,


XCKML521

XCKML115H29, XCKML515H29, XCKML115, XCKML515


15.45

22

14.65

5.5

20

5.5

(2)
(1)

5
15

35.6

(1)
=

(1)

26.3

61.5
77

(2)

(1)

6.2

135

6.5

81

5.5

6.2

129

6.5

11.5

59
11.5

34.5

(1)

(1)

26.3

61.5

15
35.6

(1) XCKMLpppH29: 3 entries tapped M20 x 1.5. XCKMLppp: 3 tapped entries for n 13 cable gland.
(2) 2 centring holes 3.9 0.2, for cover fixing holes alignment.
2 elongated holes 6.2 x 6.5, inclined at 26 30' to the vertical axis, for M5 screws.

8
9
10

1/81

Limit switches

Presentation

OsiSense XC Standard, Classic format


Metal, types XCK M and XCK L
Variable composition

1
2

Spring-rod lever
with thermoplastic
end (4)

Spring-rod lever,
metal (4)

Variable length
thermoplastic roller
lever (4)

Round rod lever,


thermoplastic, 6 mm
L = 200 mm (5)

ZCK D81

ZCK D91

ZCK D41

ZCK D59

3
4
5
6
7
8
9
10

Cats whisker

Spring rod

ZCK D06

ZCK D08

Thermoplastic roller
lever (4)

Steel roller lever (4)

Steel ball bearing


mounted roller lever (4)

ZCK D15

ZCK D16

ZCK D17

Thermoplastic roller
lever 1 direction
of actuation

Thermoplastic
roller lever plunger
with protective
boot, 1 direction
of actuation

Steel roller lever


plunger 1 direction
of actuation

Steel roller lever plunger


with protective boot
1 direction of actuation

ZCK D21

ZCK D219

ZCK D23

ZCK D239

Metal end plunger

Metal end plunger


with protective boot

Steel roller plunger

Steel roller plunger with


with protective boot

ZCK D10

ZCK D109

ZCK D02

ZCK D029

Body with 2-pole contact, 3 cable


entries for Pg 11 (1) (2)

Body with 2-pole contact, with incorporated


cable gland (1) (3)

ZCK M1, M5, M6, M7, M9


ZCK M8

ZCK L1, L5, L6, L7


ZCK L8

Body with 3-pole contact, 3 cable


entries for Pg 11 (1) (2)

Body with 3-pole contact, with incorporated


cable gland (1) (3)

ZCK MD3

ZCK LD3

(1) For further information, see page 1/84.


(2) For 3 cable entries tapped ISO M20 x 1.5, add H29 to the reference. Example: ZCK M1 becomes ZCK M1H29.
For one cable entry with 1/2" NPT adaptor, add H7 to the reference. Example: ZCK M1 becomes ZCK M1H7.
(3) For one cable entry tapped 1/2" NPT, add H7 to the reference. Example: ZCK L1 becomes ZCK L1H7.

1/82

Limit switches

Presentation (continued)

OsiSense XC Standard, Classic format


Metal, types XCK M and XCK L
Variable composition

1
Square rod lever,
steel, U 3 mm
L = 125 mm (5)

Round rod lever,


glass fibre, 3 mm
L = 125 mm (5)

Round rod lever,


thermoplastic, 6 mm
L = 200 mm (5)

ZCK Y54

ZCK Y55

ZCK Y59

2
3

Spring-rod lever
withthermoplastic
end (4)

Spring-rod lever,
metal (4)

ZCK Y81

ZCK Y91

Variable length
thermoplastic roller
lever, (4)

Variable
length steel
roller lever
(4)

Variable length
elastomer
roller lever,
50 mm (4)

Elastomer
roller lever,
50 mm (4)

ZCK Y41

ZCK Y43

ZCK Y49

ZCK Y39

4
5
6

Thermoplastic roller
lever (4)

Steel roller
lever (4)

Steel ball bearing


mounted roller
lever (4)

ZCK Y31

ZCK Y33

ZCK Y34

For actuation from


left AND right or from
left OR right

ZCK D05

9
10

: head assuring positive opening operation.


(4) Adjustable throughout 360 in 5 steps, or in 90 steps by reversing the notched washer.
(5) Adjustable throughout 360 in 5 steps, or in 45 steps by reversing the lever mounting.

1/83

Limit switches

References

OsiSense XC Standard, Classic format


Metal, types XCK M and XCK L
Adaptable sub-assemblies

Bodies with 2-pole contact


With contact block

Scheme

Positive
operation (1)

Cable entry

Reference

Weight
kg

Pg 11
ISO M20 x 1.5
1/2" NPT (2)

ZCK M1
ZCK M1H29
ZCK M1H7

0.210
0.210
0.210

Pg 11
ISO M20 x 1.5
1/2" NPT (2)

ZCK M5
ZCK M5H29
ZCK M5H7

0.210
0.210
0.210

Pg 11
ISO M20 x 1.5
1/2" NPT (2)

ZCK M6
ZCK M6H29
ZCK M6H7

0.210
0.210
0.210

Pg 11
ISO M20 x 1.5
1/2" NPT (2)

ZCK M7
ZCK M7H29
ZCK M7H7

0.210
0.210
0.210

Pg 11
ISO M20 x 1.5
1/2" NPT (2)

ZCK M8
ZCK M8H29
ZCK M8H7

0.210
0.210
0.210

Pg 11
ISO M20 x 1.5

ZCK M9
ZCK M9H29

0.210
0.210

Pg 11
1/2" NPT

ZCK L1
ZCK L1H7

0.210
0.210

Pg 11
1/2" NPT

ZCK L5
ZCK L5H7

0.210
0.210

Pg 11
1/2" NPT

ZCK L6
ZCK L6H7

0.210
0.210

Pg 11
1/2" NPT

ZCK L7
ZCK L7H7

0.210
0.210

Pg 11
1/2" NPT

ZCK L8
ZCK L8H7

0.210
0.210

NC + NC
snap action
(XE2S P2141)

21
22
21

13
21

23
24

22

14

22

13
13
14

21
22
11

21

22

NO + NO
simultaneous,
slow break
(XE2N P2131)

12

NC + NC
simultaneous,
slow break
(XE2N P2141)

13

NO + NC
make before break,
slow break
(XE2N P2161)

14

ZCK Mp

11

12

NC + NO
break before make,
slow break
(XE2N P2151)

14

For limit switches type XCK M


NC + NO
snap action
(XE2S P2151)

21
22
21

13
21
22

14

22

13
13
14

21
22

23

NO + NO
simultaneous,
slow break
(XE2N P2131)

24

11

NC + NC
simultaneous,
slow break
(XE2N P2141)

12

ZCK Lp

NO + NC
make before break,
slow break
(XE2N P2161)

13

NC + NO
break before make,
slow break
(XE2N P2151)

14

14

For limit switches type XCK L


NC + NO
snap action
(XE2S P2151)

(1)
: NC contact with positive opening operation.
(2) 3 tapped entries, one with metal adaptor for 1/2" NPT (USASB2-1) conduit.

8
9
10

1/84

References (continued)

Limit switches

OsiSense XC Standard, Classic format


Metal, types XCK M and XCK L
Adaptable sub-assemblies

Bodies with 3-pole contact


With contact block

Scheme

Positive
operation (1)

Cable entry

Reference

Weight
kg

Pg 13.5
ISO M20 x 1.5
1/2" NPT (2)

ZCK MD31
ZCK MD31H29
ZCK MD31H7

0.210
0.210
0.210

Pg 13.5
ISO M20 x 1.5
1/2" NPT (2)

ZCK MD39
ZCK MD39H29
ZCK MD39H7

0.210
0.210
0.210

Pg 13.5
ISO M20 x 1.5
1/2" NPT (2)

ZCK MD37
ZCK MD37H29
ZCK MD37H7

0.210
0.210
0.210

Pg 13.5
ISO M20 x 1.5
1/2" NPT (2)

ZCK MD35
ZCK MD35H29
ZCK MD35H7

0.210
0.210
0.210

Pg 11
1/2" NPT

ZCK LD31
ZCK LD31H7

0.210
0.210

Pg 11
1/2" NPT

ZCK LD39
ZCK LD39H7

0.210
0.210

Pg 11
1/2" NPT

ZCK LD37
ZCK LD37H7

0.210
0.210

Pg 11
1/2" NPT

ZCK LD35
ZCK LD35H7

0.210
0.210

33

13
14
13

34
21

13

14

21

13

14

33

14

22

22

31
31
32

34

NC + NO + NO
break before make,
slow break
(XE3N P2151)

31

NC + NC + NO
break before make,
slow break
(XE3N P2141)

32

ZCK MD3p

21

NC + NC + NO
snap action
(XE3S P2141)

22

NC + NO + NO
snap action
(XE3S P2151)

32

For limit switches type XCK M

1
2
3

33

13
14
13

34
21

13

14

21

13

14

33

14

22

22

31
31
32
31
32

34

NC + NO + NO
break before make,
slow break
(XE3N P2151)

21

ZCK LD3p

NC + NC + NO
break before make,
slow break
(XE3N P2141)

22

NC + NC + NO
snap action
(XE3S P2141)

32

For limit switches type XCK L


NC + NO + NO
snap action
(XE3S P2151)

(1)
: NC contact with positive opening operation.
(2) 3 tapped entries, one with metal adaptor for 1/2" NPT (USASB2-1) conduit.

4
5
6
7
8
9
10

1/85

References (continued)

Limit switches

OsiSense XC Standard, Classic format


Metal, types XCK M and XCK L
Adaptable sub-assemblies

Contact blocks
Type of contact

NC + NC
snap action

13

21
22

13
14

21
22

14
13
14

21

23
24

21
22

22
11
12

13

14

NO + NO
simultaneous,
slow break

21

NC + NC
simultaneous,
slow break

XE2N P21p1

11

NO + NC
make before break,
slow break

22

NC + NO
break before make,
slow break

XE2S P21p1

12

snap action

For bodies

Positive
operation (1)

Reference

Weight
kg

2-pole contact
NC + NO

Scheme

ZCK M1
ZCK L1

XE2SP2151

0.020

ZCK M5
ZCK L5

XE2NP2151

0.020

ZCK M6
ZCK L6

XE2N P2161

0.020

ZCK M7
ZCK L7

XE2N P2141

0.020

XE2N P2131

0.020

ZCK M9

XE2SP2141

0.020

ZCK MD31
ZCK LD31

XE3S P2151

0.035

ZCK MD39
ZCK LD39

XE3S P2141

0.035

ZCK MD37
ZCK LD37

XE3N P2141

0.035

ZCK MD35
ZCK LD35

XE3N P2151

0.035

ZCK M8
ZCK L8

(1)

13
14
13
13

14

13

33

14

31

21

34

31
32

21

22

31
32

Accessories for limit switches type XCK M


Tap-off terminal
for cabling continuity
XCK Z09

22

: NC contact with positive opening operation or sub-assembly assuring positive opening operation.

Description

14

NC + NO + NO
break before make,
slow break

33

21

NC + NC + NO
break before make,
slow break

34

NC + NC + NO
snap action

XE3p P21pp

22

32

3-pole contact
NC + NO + NO
snap action

AB1 R11

10

1/86

Sold in
lots of
1

25
Clip-in markers
(strips of 10 numbers: 0 to 9)
Other markers, please consult our Customer Care Centre.

Other versions

Gold flashed contacts.


Please consult our Customer Care Centre.

Unit
reference
XCK Z09
AB1 R11

Weight
kg
0.010
0.002

Limit switches

Operation

OsiSense XC Standard, Classic format


Metal, types XCK M and XCK L
Adaptable sub-assemblies

Heads ZCK D10, D109 with body


ZCK M1, L1
1.8

21-22
13-14
21-22
13-14

4.5(P)

0.9

1.8

4.5(P)

1.8 3.2(P)

21-22
13-14

5.5mm

ZCK MD39, LD39


21-22
31-32
13-14
21-22
31-32
13-14

ZCK M5, L5
3

1.8 3.2(P)
0

5.5mm

5.5mm

0.9

ZCK M7, L7

3 4.4(P)

21-22
13-14

5.5mm

ZCK MD37, LD37


21-22
31-32
13-14

ZCK M6, L6
1.8

11-12
21-22

1.8

4.5(P)

ZCK M8, L8
13-14
23-24

1.8

5.5mm

1.8

5.5mm

ZCK MD31, LD31


21-22
33-34
13-14
21-22
33-34
13-14

3.2(P)

5.5mm

ZCK M9
1.8

11-12
21-22
11-12
21-22

4.5(P)
5.5mm

0.9

ZCK MD35, LD35


1.8 3.2(P)

21-22
33-34
13-14

5.5mm

5.5mm

0.9

Heads ZCK D02, D029 with body


ZCK M1, L1
3.1(A) 7.8(P)

21-22
13-14
21-22
13-14

ZCK M5, L5
3.1(A) 5.6(P)

21-22
13-14

1.5

3.1(A) 7.8(P)

mm

ZCK MD37, LD37


21-22
31-32
13-14

3.1(A) 5.6(P)
0

5.2 mm

3.1

ZCK M7, L7

7.6(P)

ZCK M8, L8

5.6(P)

11-12
21-22

9mm

9mm

3.1(A)

ZCK MD31, LD31


3.1(A) 7.8(P)

21-22
33-34
13-14
21-22
33-34
13-14

mm

1.5

5.2(A)

13-14
23-24

3.1(A)

mm

ZCK MD39, LD39


21-22
31-32
13-14
21-22
31-32
13-14

5.2

ZCK M6, L6
21-22
13-14

9mm

ZCK M9
11-12
21-22
11-12
21-22

3.1(A) 7.8(P)
0

1.5

mm

ZCK MD35, LD35


21-22
33-34
13-14

3.1(A) 5.6(P)
0

5.2 mm

mm

1.5

Heads ZCK D21, D23, D219, D239 with body


ZCK M1, L1
4.6(A) 11.1(P)

21-22
13-14
21-22
13-14

ZCK M5, L5
4.6(A) 8(P)

21-22
13-14

2.2

4.6(A) 11.1(P)

ZCK MD37, LD37


21-22
31-32
13-14

4.6(A) 8(P)
7.6 mm

2.2

4.6(A)

4.6(A) 11.1(P)

ZCK M8, L8

8(P)

11-12
21-22

4.6(A)

mm

ZCK MD31, LD31


21-22
33-34
13-14
21-22
33-34
13-14

mm

ZCK M7, L7

7.6 11.1(P)

mm

ZCK MD39, LD39


21-22
31-32
13-14
21-22
31-32
13-14

7.6 mm

ZCK M6, L6
21-22
13-14

mm

13-14
23-24

4.6(A)

mm

ZCK M9
11-12
21-22
11-12
21-22

4.6(A) 11.1(P)
0

2.2

mm

ZCK MD35, LD35


21-22
33-34
13-14

4.6(A) 8(P)
7.6 mm

mm

2.2

Heads ZCK D15, D16, D17 with body


ZCK M1, L1
21-22
13-14
21-22
13-14

26
0

11

58 (P)
70

ZCK MD39, LD39


26

21-22
31-32
13-14
21-22
31-32
13-14

58(P)

ZCK M5, L5
26 42 (P)

21-22
13-14

36

70

ZCK MD37, LD37


21-22
31-32
13-14

26 42(P)
0

36 70

40

21-22
13-14

24

ZCK M7, L7

60 (P)

43 (P)

11-12
21-22

24

70

ZCK MD31, LD31


21-22
33-34
13-14
21-22
33-34
13-14

70

11

ZCK M6, L6

26

58(P)

ZCK M8, L8
13-14
23-24

24

70

70

ZCK M9
11-12
21-22
11-12
21-22

26
0

11

58 (P)

70

ZCK MD35, LD35


21-22
33-34
13-14

26 42(P)
0

36 70

70

11

Heads ZCK D41, D59, D81, D91 with body


ZCK M1, L1
26

ZCK M5, L5
26

21-22
13-14

21-22
13-14
21-22
13-14

11

26

11

70

24

11-12
21-22

70

24

70

ZCK MD39, LD39


21-22
31-32
13-14
21-22
31-32
13-14

ZCK M7, L7

40

21-22
13-14

36

ZCK M6, L6

ZCK MD37, LD37


21-22
31-32
13-14

26
0

36 70

70

ZCK MD31, LD31


21-22
33-34
13-14
21-22
33-34
13-14

26

11

70

ZCK M8, L8
13-14
23-24

24

70

ZCK M9
26

11-12
21-22
11-12
21-22

11

70

ZCK MD35, LD35


21-22
33-34
13-14

26
0

36 70

70

Heads ZCK D06, D08 with body


ZCK M1, L1
30

21-22
13-14
21-22
13-14

ZCK M6, L6

30

21-22
13-14

40

21-22
13-14

40

ZCK M7, L7

30

ZCK MD37, LD37


21-22
31-32
13-14

30
0

40

21-22
33-34
13-14
21-22
33-34
13-14

14

Contact operation

ZCK MD31, LD31

G closed
H open

30

ZCK M8, L8
13-14
23-24

11-12
21-22

30

30

30

14

ZCK MD39, LD39


21-22
31-32
13-14
21-22
31-32
13-14

ZCK M5, L5

ZCK M9
11-12
21-22
11-12
21-22

30

14

ZCK MD35, LD35


21-22
33-34
13-14

30
0

10

40

14

(A) = cam displacement


(P) = positive opening point

1/87

Limit switches

Dimensions

OsiSense XC Standard, Classic format


Metal, types XCK M and XCK L
Adaptable sub-assemblies

Bodies with contacts


ZCK L1, L5, L6, L7, L8, LD3p
ZCK L1H7, L5H7, L6H7, L7H7, L8H7, LD3pH7

(1)

41

72

58.5

63.6

64

30

(2)
30

Adaptor for 1/2" NPT conduit


DE9RA1012

(3)

(1) 3 tapped entries for ISO M20 x 1.5 or Pg 11 cable gland.


(2) Incorporated cable gland.
: 2 elongated holes 5.2 x 6.2
(3) Tapped entry for 1/2" NPT conduit.
(4) Threaded sleeve.

(4)

26

21

6
7
8
9
10

1/88

67

ZCK M1, M5, M6, M7, M8, M9, MD3p, MD3Hp29, MD3pH7
ZCK M1H29, M5H29, M6H29, M7H29, M8H29, M9H29
ZCK M1H7, M5H7, M6H7, M7H7, M8H7

41
52

Dimensions (continued)

Limit switches

OsiSense XC Standard, Classic format


Metal, types XCK M and XCK L
Adaptable sub-assemblies

Plunger heads
ZCKD10

ZCK D109

ZCKD02

14
4

ZCK D029

30

48.5

14

30

14

ZCK D21, D23

ZCK D219, D239

14

14

14
8

13

13

54

48

54

Rotary heads
ZCK D15, D16, D17

ZCKD41

ZCKD59

51

44.5

37

15

31.7

43

34

(1)

55

56

ZCK D81

(2)

50 ...104.5

34.5
60.5

29.5...84

5.5

5
6

ZCK D91

51
51

112

179

7
8

56

56

Multi-directional heads
ZCK D06

14

ZCK D08

14

129.5

142.5

9
10

(1) 190 max.


(2) 215.5 max.
Note: operating lever spindle threaded M6.

1/89

Вам также может понравиться