Theater Layout

Large

System Summary
This summary is intended to explain, in general terms, some of the possible uses and reasons for having the
recommended equipment shown in the following pages.
These pages are only meant to be a starting point, a tool to begin the design process which will give you
a better understanding of the types of components which are needed to put together a flexible and fully
functional theatrical lighting system.
If, after reviewing this information, you have further questions you are invited to contact a local Leviton
Lighting Controls Representative for further assistance in putting together a system that meets the needs
of your facility.

General Layout
This layout is recommended for a Large Proscenium stage. This Bill of Material is recommended for a
large sized Community Theatre, Professional Stage or High School.

Dimming & Control


The dimmers dedicated to the stage circuits will allow a great deal of flexibility for lighting several different
types of productions or events which may be presented in a facility of this type, while allowing for future
growth as the need arises. The difference in dimmer count between the circuits shown on the Theatre
Layout and the Bill of Material is the number of circuits being dedicated to House Lights.
The control console allows for rapid reprogramming of the system for each of the different events and the
ability to save the event setup on a disk for future access. All that is needed to recall a saved setup and cues
is to insert the disk and load the saved program. This can be extremely important for a facility that hosts several different events or productions.
The Hand Held Remote Unit allows for the flexibility of focusing lights and reviewing stage looks without
having to be sitting at the control console location. This can save a great deal of time when preparing for
a production.
The Network Protocol Converter is used for programming the House Lighting control system, which can be
programmed to control House Lights and Stage Lights allowing limited use of the Stage lighting without
access to the Control Console. It is also used to combine several different control protocols to control the
dimming system.

Power Distribution
The combination of Connectors Strips, Floor Pockets and Wall Pockets helps to maximize the flexibility of
system by providing power distribution to all areas of the stage, as well as the Front of House positions.

Fixtures & Accessories


The selection of Fixtures and Accessories provides for a versatile lighting plot using more general area
lighting while maintaining a plentiful amount of fixtures for highlighting key areas. The actual fixture
requirement, however, would depend upon the requirements of the facility.

Theater Layout Large


3 Circuits
(168-170)

3 Circuits
(171-173)

3 Circuits
(165-167)

28 Circuits
(119-146)

Fourth Electric
18 Circuits
(101-118)
3 Circuits
(159-161)

3 Circuits
(162-164)
Third Electric Pipe
18 Circuits
(83-100)
Second Electric Pipe
36 Circuits
(47-82)
3 Circuits
(156-158)
3 Circuits
(150-152)

Stage Manager's Panel

3 Circuits
(147-149)

First Electric Pipe

3 Circuits
(153-155)

Proscenium Line

Apron Line

its
ircu
8C

uit
circ
2-4

s
xe
bo

(39-46)

(31-38) 8
Side Slot
(One Each Side)
Designer's Remote Station

Beam
(House Ceiling)

30 Circuits
(1-30)

C
L

Control Console (Control Booth)


Located at rear of auditorium

Followspot

Notes:
All load circuits are 2 wire
(no common neutrals)
All load circuits terminate
in the Dimmer Bank
Locate Dimmer bank remotely
Side slots (vertical positions)
located approximately below
beam on left and right wall

Beam location to be determined by


plotting a 40 angle from house to
ceiling to head height of an actor
standing approximately under the
first electric pipe.
Multi-Conductor cable lengths to be
determined to allow electric pipes to
lower to the stage floor maintenance.

KEY
40 Ellipsoid

8" Theater Frensel

Connector Strip

30 Ellipsoid

6' Borderlight

Floor Pocket

20 Ellipsoid

3 Light Far Cyc

Wall Box

Zoom Ellipsoid

Followspot

Grid Junction Box

6" Theater Fresnel

Cir
cu
its
2-4
cir
cu
it b
ox
es

HH REMOTE
RECEPTACLE STATION
MODEL 7-4041

HH REMOTE
RECEPTACLE STATION
MODEL 7-4041

HAND HELD
REMOTE UNIT
MODEL 7-2021

HH REMOTE
RECEPTACLE STATION
MODEL 7-4041
7

i96e DIMMER RACK


MODEL 4-0114E

1
5
3

-N.P.C.NETWORK
PROTOCOL
CONVERTER
ENCLOSURE

11

INNOVATOR 600
CONTROL CONSOLE
MODEL# 7-0600
SUPPLIED WITH:
(2) SVGA COLOR MONITOR MODEL# 7-2091

CONSOLE CONTROL
RECEPTACLE STATION
MODEL 7-4201

2
1
9

10
3

D8000 5-BUTTON
CONTROL STATION
MODEL 000-KB05X-00X

D8000 5-BUTTON
CONTROL STATION
MODEL 000-KB05X-00X

D8000 LCD CONTROL STATION MODEL


000-KLCD0-00X

LOAD CIRCUIT:
(96) 20 A, 120VAC, 2 WIRE
[PULL SEPARATE NEUTRALS]
LOAD CIRCUIT:
(90) 20 A, 120VAC, 2 WIRE
[PULL SEPARATE NEUTRALS]
MAIN FEED:
BUSSING RATED FOR 800 AMPS. MAX. CAPACITY. 3,
4 WIRE PLUS GROUND
208Y/120VAC, 60HZ FEED. AMPERAGE
RATING OF MAIN DISCONNECT TO BE
DETERMINED BY OTHERS.

D8000 LCD CONTROL STATION MODEL


000-KLCD0-00X

NOTES: (UNLESS OTHERWISE SPECIFIED)


1. THIS DRAWING DOES NOT INDICATE THE NUMBER OR SIZE
OF CONDUITS REQUIRED, BUT THE SEPARATION OF GROUPS OF WIRES.
INTERCONNECTING WIRE AND CONDUIT ARE NOT BY LEVITON.

3. PROVIDE AN EQUIPMENT GROUND, AS REQUIRED BY THE NATIONAL


ELECTRICAL CODE, BETWEEN BUILDING SERVICE ENTRANCE AND THE
DIMMER EQUIPMENT.
4. CABLE RUNS ARE CONTINUOUS BETWEEN CONNECTED DEVICES. NO
SPLICING ALLOWED.

(1)- BELDEN 9829 LOW CAPACITANCE SHIELDED 2 TWISTED


PAIR CABLE PER WIRING CHART LABELED "DMX A" PER DRAWING.

5. "DMX" CONTROL CABLE RUN FROM END TO END, NOT TO


EXCEED 1000 FEET. DAISY CHAIN ONLY, NO STARRING ALLOWED.

(1)- BELDEN 9829 LOW CAPACITANCE SHIELDED 2 TWISTED


PAIR CABLE PER WIRING CHART LABELED "DMX B" PER DRAWING.

(1)- BELDEN 9830 LOW CAPACITANCE SHIELDED 3 TWISTED


PAIR CABLE PER WIRING CHART LABELED "HHR".
(1)- BELDEN 9829 LOW CAPACITANCE SHIELDED 2 TWISTED
PAIR CABLE PER WIRING CHART LABELED "LN1"
-------- AND --------(2)- #14 AWG -MINIMUM- STRANDED CU CONDUCTORS
LABELED "COM" & "+V" PER WIRING CHART.
(1)- BELDEN 9829 LOW CAPACITANCE SHIELDED 2 TWISTED
PAIR CABLE PER WIRING CHART LABELED "LN2"
-------- AND --------(2)- #14 AWG -MINIMUM- STRANDED CU CONDUCTORS
LABELED "COM" & "+V" PER WIRING CHART.

10

LINE: 15AMP, 120VAC, 2 WIRE PLUS GROUND, 60HZ.

11

(1)- BELDEN 9829 LOW CAPACITANCE SHIELDED 2 TWISTED


PAIR CABLE PER WIRING CHART LABELED "DMX 1" PER DRAWING.

D8000 5-BUTTON
CONTROL STATION
MODEL 000-KB05X-00X

D8000 5-BUTTON
CONTROL STATION
MODEL 000-KB05X-00X

CABLES PROVIDED BY LEVITON.


1

25' CONSOLE DMX CONTROL CABLE. MODEL 7-3014.

6' CONSOLE POWER CORD PROVIDED WITH CONTROL CONSOLE.

25' HHR CONTROL CABLE. MODEL 7-3033.

2. WHEREVER CONTROL WIRES SHOWN MUST BE RUN CLOSE


TO A.C. CONTROL AND/OR POWER CIRCUITS, THESE CONTROL
WIRES MUST BE RUN IN SEPARATE METAL CONDUIT.

LINE: 15AMP, 120VAC, 2 WIRE PLUS


COMPUTER GRADE GROUND, 60HZ.

WIRE RUNS NOT BY LEVITON.


1

INNOVATOR 24/48
CONTROL CONSOLE
MODEL# 7-0048
SUPPLIED WITH: COLOR SVGA MONITOR
MODEL# 7-2091

CONSOLE CONTROL
RECEPTACLE STATION
MODEL 7-4011

LUMANET WIRING CHART FOR BELDEN #9829 "LN" & 14


AWG MIN. CABLE RUN(S)

PAIR
NO.
SHIELD

COLOR
SHIELD
WT W/BL STRIPE
BL W/WT STRIPE
WT W/OR STRIPE
OR W/WT STRIPE

TERMINAL FUNCTION

1
2

*
1
2
N/C
N/C

REM+
REM-

3
4

COM
+V

BLACK (14AWG)
RED (14AWG)

* SHIELDS TO BE TIED TOGETHER AND INSULATED.

6. LUMANET "LN" CONTROL CABLE RUN FROM END TO END, NOT TO


EXCEED 2000 FEET. DAISY CHAIN ONLY, NO STARRING ALLOWED.

= ON
"DIP-SWITCH SETTING CHART"
1

7. 3 1/2" DEEP INDUSTRY STANDARD GANG BACK BOXES NOT PROVIDED BY


LEVITON. BACK BOXES MUST BE GROUNDED.

8.

1
2
3

SET DEVICE ADDRESS TO THE NUMBER SHOWN IN THE SYMBOL.

4
5

9. HANDHELD REMOTE CONTROL "HHR" CABLE WIRE RUN FROM


FURTHEST CONTROL CONSOLE LOCATION TO FURTHEST HANDHELD
REMOTE UNIT LOCATION, INCLUDING PLUG-IN CABLES, NOT TO
EXCEED 1000 FEET.

6
7
8

DMX WIRING CHART FOR BELDEN #9829


"DMX" CABLE RUNS
COLOR
SHIELD
WT W/BL STRIPE
BL W/WT STRIPE
WT W/OR STRIPE
OR W/WT STRIPE

PAIR
NO.
SHIELD
1
2

PIN/
TERM.
1
2
3
4
5

Bill of Material
Typical Large Theater
ITEM

QTY

PART NO.

DESCRIPTION

1.0

CTP-4-0114E

1.1
1.2
1.3
1.4

2
93
3
2

OPT-40001-00
CTP-4-0012E
CTP-4-0099
CTP-4-0311E

DIMMING & CONTROL


Dimmer Rack
i96e Dimmer Bank, with:
2 - 48 Module 120V i96e Dimmer Rack(s) for:
186 - 20A Circuits
Bussed for: 1 - 800A Maximum 120/208 Volt,
3 Phase 4 Wire plus Ground Feed, with Main Lugs Only
i96e Rack Ground Bus Kit
ie500 2.4kW 120V Dual Dimmer Module
i Air Flow Module (Single Slot)
ie 120V Control Module

2.0

CTP-7-2300

Network Protocol Converter


NPC/XP, Surface Mount

3.0
3.1
3.2
3.3
3.4
3.5
3.6

1
1
2
1
2
1
1

CTP-7-0600
OPT-31388-00
CTP-7-2091
CTP-7-5064
CTP-7-5107
CTP-7-3014
CTP-7-3033

Control Console
Innovator 600 Control Console
Second Monitor Card
Color Monitor - SVGA, 17"
Innovator 600 Console Dust Cover
Monitor Dust Cover (17")
25' DMX Control Cable
25' Hand-Held Remote Control Cable

4.0

CTP-7-4201

5.0
5.1
5.2
5.3
5.4
5.5
5.6

1
1
1
1
1
1

CTP-7-0048
CTP-7-5052
CTP-7-2091
CTP-7-5061
CTP-7-5107
CTP-7-3014
CTP-7-4011

6.0
6.1

1
1

CTP-7-2021
CTP-7-3034

7.0

CTP-7-4041

8.0

000-KLCD0-00X

Master Control Station


D8000 LCD Station w/ 15 Buttons
Note: Requires 4-gang back box by others.

9.0

000-KB050-00X

Remote Station
D8000 Station w/ 5 Buttons
Note: Requires 1-gang back box by others.

10.0

BOI-172000-00

11.0

BOI-172000-00

11.1

BOI-175000-00

Receptacle Wallplate
Two-Gang Control Wallplate, with:
1 - DMX Input Receptacle
1 - Hand-Held Remote Receptacle (System)
Note: Requires 2-gang back box by others.
Stage Manager's Panel
Innovator 24/48 Control Console
Console Worklight
Color Monitor - SVGA, 17"
Innovator 24/48 Console Dust Cover
Monitor Dust Cover (17")
25' DMX Control Cable
Single-Gang Control Wallplate, with:
1 - DMX Input Receptacle
Note: Requires 1-gang back box by others.
Designer's Remote
Hand-Held Remote
50' Hand-Held Remote Control Cable
Designer's Remote Receptacle Wallplate
Single-Gang Control Wallplate, with:
1 - Hand-Held Remote Receptacle (Unit)
Note: Requires 1-gang back box by others.

DISTRIBUTION
Connector Strip (Front of House/Beam)
BAL Series Connector Strip, with:
45
- Feet of 4.75" high x 3.375" deep Wireway
30
- 20A Circuits
30
- 20A 2P&G (Stagepin) 18" Pigtail Receptacles
10
- Double Pipe Hanger Brackets
and Standard 2" Die Cut Circuit Labels on 1 Side
Connector Strip (1st Electric)
BAL Series Connector Strip, with:
36
- Feet of 4.75" high x 3.375" deep Wireway
36
- 20A Circuits
36
- 20A 2P&G (Stagepin) 18" Pigtail Receptacles
8
- Double Pipe Hanger Brackets
and Standard 2" Die Cut Circuit Labels on 1 Side
Gridiron Junction Box, 36 Circuit

ITEM

QTY

PART NO.

DESCRIPTION
Connector Strip (2nd Electric)
BAL Series Connector Strip, Set Up For Borderlights with:
36
- Feet of 4.75" high x 3.375" deep Wireway
18
- 20A Circuits
18
- 20A 2P&G (Stagepin) 18" Pigtail Receptacles
8
- Double Pipe Hanger Brackets
and Standard 2" Die Cut Circuit Labels on 1 Side
Gridiron Junction Box, 18 Circuit

12.0

BOI-172000-00

12.1

BOI-175000-00

13.0

BOI-172000-00

13.1

BOI-175000-00

14.0

BOI-172000-00

14.1

BOI-175000-00

15.0

BOI-174000-00

16.0

BOI-174000-00

16.1
16.2

2
6

BOI-157000-01
CTP-152-031

17.0

CTP-6-7203

Floorpocket
Floorpocket, with:
3 - 20A 2P&G (Stagepin) Flush Receptacles

18.0

20

CTP-6-9205

Stage Cables
Cable - Stage 12/3 SO 20A 2P&G (Stagepin) - 5 foot

19.0

25

CTP-6-9210

Cable - Stage 12/3 SO 20A 2P&G (Stagepin) - 10 foot

20.0

10

CTP-6-9225

Cable - Stage 12/3 SO 20A 2P&G (Stagepin) - 25 foot

21.0

10

CTP-142-000

24" Two-fer, 20A 2P&G (Stagepin)

22.0

CTP-650-025

22.1
22.2

4
4

OPT-00002-02
CTP-176-601

23.0

18

CTP-650-035

23.1
23.2

18
18

OPT-00002-02
CTP-176-601

Connector Strip (3rd Electric)


BAL Series Connector Strip, Set Up For Borderlights with:
36
- Feet of 4.75" high x 3.375" deep Wireway
18
- 20A Circuits
18
- 20A 2P&G (Stagepin) 18" Pigtail Receptacles
8
- Double Pipe Hanger Brackets
and Standard 2" Die Cut Circuit Labels on 1 Side
Gridiron Junction Box, 18 Circuit
Connector Strip (4th Electric)
BAL Series Connector Strip, Set Up For CYC Lights with:
36
- Feet of 4.75" high x 3.375" deep Wireway
28
- 20A Circuits
28
- 20A 2P&G (Stagepin) 18" Pigtail Receptacles
8
- Double Pipe Hanger Brackets
and Standard 2" Die Cut Circuit Labels on 1 Side
Gridiron Junction Box, 28 Circuit
Wall Pocket Plugging Box (Side Slots)
WP Series Plugging Box, with:
1
- Wall Pocket Plugging Box
4
- 20A 2P&G (Stagepin) 18" Pigtail Receptacles
Wall Pocket Plugging Box (Tormentors)
WP Series Plugging Box, with:
1
- Wall Pocket Plugging Box
3
- 20A 2P&G (Stagepin) 18" Pigtail Receptacles
Tormentor Boom Pipe (1-1/2") - Surface Mtd. - 12 foot
Single Side-Arm

LUMINAIRES & ACCESSORIES


40 Degree Ellipsoidal Spotlight
40 Degree Ellipsoidal with "C" Clamp, Color Frame,
Safety Cable and 3' cord
20A 2P&G (Stagepin) Connector (attached to Fixture)
575W HX601 Lamp
30 Degree Ellipsoidal Spotlight
30 Degree Ellipsoidal with "C" Clamp, Color Frame,
Safety Cable and 3' cord
20A 2P&G (Stagepin) Connector (attached to Fixture)
575W HX601 Lamp
Note: The 30 Degree Ellipsoidal Spotlight is
shipped with the parts to convert it to a
20 Degree or 40 Degree unit.

24.0

14

CTP-650-045

24.1
24.2

14
14

OPT-00002-02
CTP-176-601

25.0

CTP-650-095

25.1
25.2

6
6

OPT-00002-02
CTP-176-601

26.0

CTP-213-525

26.1
26.2
26.3
26.4
26.5

8
8
8
8
8

OPT-00002-02
CTP-120-015
CTP-118-032
CTP-138-059
CTP-176-194

20 Degree Ellipsoidal Spotlight


20 Degree Ellipsoidal with "C" Clamp, Color Frame,
Safety Cable and 3' cord
20A 2P&G (Stagepin) Connector (attached to Fixture)
575W HX601 Lamp
15 -35 Degree Zoom Ellipsoidal Spotlight
15-35 Degree Zoom Ellipsoidal with "C" Clamp,
Safety Cable and 3' cord
20A 2P&G (Stagepin) Connector (attached to Fixture)
575W HX601 Lamp
8" Fresnel
8" Theater Fresnel with "C" Clamp and
3' cord
20A 2P&G (Stagepin) Connector (attached to Fixture)
Color Frame
Eight-Leaf Barndoor
Safety Cable
2000W BVW Lamp

ITEM

QTY

27.0

32

CTP-213-515

27.1
27.2
27.3
27.4

32
32
32
32

OPT-00002-02
CTP-120-005
CTP-118-013
CTP-176-169

28.0

ALT-R40-6-3

28.1
28.2
28.3
28.4
28.5
28.6
28.7

24
48
16
32
32
32
96

ALT-52-138GM
ALT-INSTALL
CTP-138-059
CTP-238-021
CTP-238-022
CTP-238-023
BOI-157000-00

29.0

CTP-108-415

29.1
29.2
29.3
29.4
29.5

18
18
18
12
18

OPT-00002-02
CTP-120-058
CTP-138-064
CTP-138-059
CTP-176-182

Three Light Far-Cyc


Three Light Far-Cyc with "C" Clamp and
3 - 3' cords
20A 2P&G (Stagepin) Connector (attached to Fixture)
Color Frame
Safety Frame
Safety Cable
1000W FFT Lamp

30.0

CTP-176-601

Spare Lamps (10% of each type)


575W HX601 Lamp

31.0

CTP-176-169

750W BTN Lamp

32.0

10

BOI-157000-00

250W 250PAR/CAP/SPL/FL30 Flood Lamp (Osram/Sylvania)

33.0

CTP-176-194

2000W BVW Lamp

34.0

CTP-176-182

1000W FFT Lamp

35.0

30

CTP-138-003

Patterns and Holders


Pattern Holder For Ellipsoidal Luminaires

36.0

BOI-157000-01

Set of 6 Patterns

37.0

50

BOI-128000-00

Color Media
Sheet of Lee Color Media, Standard Colors

PART NO.

DESCRIPTION
6" Fresnel
6" Theater Fresnel with "C" Clamp and
3' cord terminated
20A 2P&G (Stagepin) Connector (attached to Fixture)
Color Frame
Eight-Leaf Barndoor
750W BTN Lamp
Borderlight
6' Three-Circuit Borderlight with "C" Clamp and Hanging
Brackets, Color/Roundel Frames and 6 - 3' cords
20A 2P&G (Stagepin) Connector
Altman Connector Installation
Safety Cable
Roundel - Red
Roundel - Blue
Roundel - Green
250W 250PAR/CAP/SPL/FL30 Flood Lamp (Osram/Sylvania)

SYSTEM SERVICES
38.0

Freight: This project is quoted F.O.B. factory, surface freight prepaid


to the jobsite. Any special delivery services (airfreight,
expedited delivery, etc.) may incur additional charges.
Engineering Services: System Check-Out, Commissioning and Training
by a Factory Authorized Engineer.

39.0

Warranty: Leviton lighting systems are warranted against defects in


material and workmanship for two (2) years from date of
shipment. Units returned to the appropriate Leviton office
will be repaired at no charge, excepting surface freight.
Contact your Leviton Representative for details.

40.0

41.0

Factory Services: Complete sets of working drawings detailing the


equipment to be supplied, submitted for approval
prior to manufacture. Operation and maintenance
manuals provided after shipment. Working drawings
and manuals require 6 weeks for preparation after
shipment of equipment.

For more information, contact your Leviton representative or:


Leviton Manufacturing Co., Inc.
59-25 Little Neck Parkway, Little Neck, New York 11362-2591
Phone: 1-800-367-5424 FAX: 1-800-832-9538
Tech Line (8:30AM-7:30PM E.S.T. Monday-Friday) 1-800-824-3005
www.leviton.com
2003 Leviton Manufacturing Co., Inc. All rights reserved.

G-6738B/E3-TP