General
Dynamic BTS Power Control is performed for Traffic channels
(TCHs) as well as for Stand alone dedicated control channels
(SDCCHs).
Power control of the SDCCHs is enabled with the switch
SDCCHREG.
All time slots on the BCCH frequency are transmitted on full power,
i.e. there is no Power Control of these time slots.
Slide
3 (32)
MS distribution
C/I Distributions
FHOP+BTSPC
FHOP+BTSPC+DTX
FHOP
Nothing
C/I
Acceptable C/I
FHOP
03813-LZU 108 3704 Uae Rev E
Acceptable C/I
no FHOP
Slide
4 (32)
Slide
MS received power
Maximum
allowed
power level
Minimum
allowed
power level
Regulation area
BTS output power
Path loss
MS received power
Base station output power (dashed) and MS signal strength (solid) versus path loss.
Quality is not taken into account.
03813-LZU 108 3704 Uae Rev E
Slide
5 (32)
Slide
6 (32)
Slide
Slide
7 (32)
Full
Sub set
Slide
8 (32)
Slide
DL quality
DL signal strength
BTS power level used
DL DTX indicator
BSC
BTS power order
Slide
9 (32)
Preparation of
input data
Filtering of
measurements
Calculation of
power order
Slide
10 (32)
Slide
Slide
11 (32)
Slide
12 (32)
Slide
Slide
13 (32)
QDESDL [dtqu]
10
20
30
40
50
60
70
rxqual
C/I [dB]
23
19
17
15
13
11
Slide
14 (32)
Slide
Slide
15 (32)
pui =
i * (SSDESDLAFR - SS FILTERED) +
i * (QDESDLAFR_dB - QFILTERED)
i = 1,2
QDESDLAFR_dB is QDESDLAFR expressed in C/I (in dB)
1 = LCOMPDL / 100
(pathloss compensation)
(quality compensation)
1 = QCOMPDL / 100
(pathloss compensation)
2 = 0.3
2 = 0.4
(quality compensation)
Slide
16 (32)
Slide
The two power orders are calculated simultaneously and the one with
the highest value (minimum down regulation) is used:
pu = max(pu1 ,pu2 )
The power order is converted to PLused representation and transmitted
to the BTS:
PLused = Int(-pu/2 ) [0..15]
where PLused is the power level. PLused = 0 represents full power and
PLused = 15 represents 30 dB down regulation.
Slide
17 (32)
If the BSC does not receive the Measurement result from a BTS, the
power regulation is inhibited for that connection. At the same time the
REGINTDL counting is suspended. When a Measurement result is
received again, power regulation and REGINTDL counting are
resumed.
The signal strength filter will not be updated when signal strength
results (measured in the Measurement report) are missing. This means
that the output from the signal strength filter is held until the next value
is received.
Missing quality values in the Measurement report are set to the worst
possible value. This means that missing quality values are interpreted as
rxqual =7.
If information about the BTS power level used is missing in the
Measurement report, the missing values are set to the latest calculated
power order.
Slide
18 (32)
Slide
-30
BSTXPWR - BSPWRMIN
Slide
19 (32)
Slide
20 (32)
10
Slide
Regulation procedure
When a TCH connection is set up, in some situations maximum
nonfigurative output power is always used, for example at:
assignment of a TCH.
assignment failure or handover failure.
intra-cell handover and subcell change.
inter-cell handover.
Slide
21 (32)
Multislot configuration
If the channel is a main channel in a multislot configuration, the
difference between the computed power order and the previous power
order must exceed a hysteresis of two dB before a new power order is
sent.
BTS power regulation on bi-directional channels is done independently
of the other channels.
For uni-directional channels BTS Power Control is activated without
starting normal power regulation. No Measurement reports will be
received for uni-directional channels. Instead the BTS power value of
the main channel is distributed to the uni-directionals in the multislot
configuration.
In a multislot configuration only the main channel is affected by the
handover power boost.
Slide
22 (32)
11
Slide
Slide
23 (32)
Slide
24 (32)
12
Slide
Slide
25 (32)
Slide
26 (32)
13
Slide
Slide
27 (32)
Slide
28 (32)
14
Slide
Slide
29 (32)
Slide
30 (32)
15
Slide
Rec. value
SSDESDL
QDESDL
-70
20
-90
30
SSDESDLAFR
QDESDLAFR
LCOMPDL
QCOMPDL
-70
20
70
30
-90(3)
40(3)
5
55
Value
range
-110 to 47
0 to 70
-110 to 47
0 to 70
0 to 100
0 to 100
REGINTDL
1 to 10
SSLENDL
3 to 15
QLENDL
SDCCHREG
8
OFF
3
ON
1 to 20
ON, OFF
BSPWRMIN
BSTXPWR
-20
-20
UPDWNRATIO
STEPLIMDL
200
OFF
300
OFF
-20 to +50
0 to 80
100 to
700
ON, OFF
Parameter name
Slide
Unit
dBm
dtqu
dBm
dtqu
%
%
SACCH
periods
SACCH
periods
SACCH
periods
dBm
dBm
%
31 (32)
Filter coefficient a
Filter length L
Filter coefficient a
0.1000
16
0.8660
0.3162
17
0.8733
0.4642
18
0.8799
0.5623
19
0.8859
0.6310
20
0.8913
0.6813
21
0.8962
0.7197
22
0.9006
0.7499
23
0.9047
0.7743
24
0.9085
10
0.7943
25
0.9120
11
0.8111
26
0.9152
12
0.8254
27
0.9183
13
0.8377
28
0.9211
14
0.8483
29
0.9237
15
0.8577
30
0.9261
Slide
32 (32)
16