CALCULATION SHEET

Bill of Quantities

Project: Emirates Transport Construction


Sl. No.

ITEM DESCRIPTION

No

STRUCTURAL STEEL CALCULATION WORKSHOP- A

1)

2)

Secondary Beam (SB 1)


Stiffner Plate 12 mm
Portal Beam SB 4
End Plate 6 % of steel l/s
3)

Roof Purlin
PU 1 202 Z 20
PU 2 CH 230x75x26
Purlin Cleates
Anti Sagrods 20 Rod
Vert w Bracing L 100x100x10
Hor. W Bracing L 100x100x10
Bracing Cleats
Bracing End plate
Knee Bracing L 50x50x5

4)

104586.5

kg

10
15
20

12.0
12.0
12.0

@
@
@

137
179
189

16440.0
32220.0
45360.0

kg
kg
kg

10
15
20

0.9
1.4
0.9

0.5
0.5
0.6

0.025
0.025
0.025

883.1
2060.6
2119.5

kg
kg
kg

140
420
280
45

1
1
1
1

@
@
@
0.4

3.86
3.86
3.86
0.016

540.4
1621.2
1080.8
2260.8

kg
kg
kg
kg

93796.8

kg

73050.0

kg

9964.8
2472.8
3000.0
5309.3

kg
kg
kg
kg

38257.6
7950.0
15600.0
918.5
1659.8
2416.0

kg
kg
kg
kg
kg

Steel Beam Rafter


Steel Framne 1

Unit

15
nos
24
420
10

2
both side
12.0
0.3
6.0
88487.6

25
50
375
16
40
80
120
750

Remarks

236640.8

Steel Columns for Workshop- A

SC 1 700/100x300x137
SC 2 1200x300x179
SC 3 700/100x300-3x189
Base Plate 25mm thk
SC 1
SC 2
SC 3
Anchor Bolts 25 mm dia
SC 1
SC 2
SC 3
Cap Plate

Qnty.

@
@
0.25
@

2435
kg/rafter
34.6
0.012
50

60.0
12.0
0.2
42

@
@
0.13
@

5.3
26
0.012
2.47

4.0

4.0
0.25
10%
1.00

@
0.25
of total
@

15.1
15.1
0.012
7248.0
4.6

Sandwich Roof Panel: >>>Aluminum sheet 0.7 mm gauge sheet with


45/250 Trapezoidal profile (Power coated) >>>35 mm thick Injected
Polyeurethan with density not less than 38 KA/m3 >>> Aluminum
Gauge Sheet 0.5 mm Gauge sheet
Roof
1
35
@
76.5

Page 1

4832.0

kg
kg

706.5
724.8
3450.0

kg
kg
kg

2677.5

m2

2677.5

m2

8
8

8.2
L20%m

CALCULATION SHEET
Bill of Quantities

Project: Emirates Transport Construction


Sl. No.

5)
6)
7)
8)
9)

ITEM DESCRIPTION

Rain water Gutter 7 mm


Ridge Cover (Approx 2.5 m
long)
Flushing 4 side
Eave side Curve sheet
Gable Side Curve sheet

No

77

154.0

77

77.0

112

224.0
77.0
35.0

m
Lm
Lm

29723.8

kg

CRANE GUTTER WITH LAP JOINT

Qnty.

Unit

1
2

Crane Beam UB 457x191x67


254X89 RSC

14
14

12
12

@
@

67
46

11256.0
7728.0

kg
kg

Crane beam connection plate

60

0.5

0.3

0.025

1766.3

kg

Rails- solid tube

14

12

28.2

4737.6

kg

Bracket Beam UB 457x191x67

30

0.5

67

1005.0

kg

6
7
8
9

Stiffener Plate for bracket


Angle 120x120x10
Gusset Plate
Stiffener Plate for Column

60
60
30
16

0.5
0.3
0.5
1.2

0.2
@
0.5
0.15

0.025
16.3
0.02
0.012

1177.5
293.4
588.8
271.3

kg
kg
kg
kg

Nut Bolts

30

60

1800

Page 2

900

Remarks

Bill of Quantities (Summary)


Project: Emirates Transport Construction

Sl.
NO.

ITEM DESCRIPTION
STRUCTURAL STEEL IN RIGID FRAME
CRANE BEAM INCLUDING CONNECTIONS

Sandwich Roof Panel: >>>Aluminum sheet 0.7


mm gauge sheet with 45/250 Trapezoidal profile
(Power coated) >>>35 mm thick Injected
Polyeurethan with density not less than 38
KA/m3 >>> Aluminum Gauge Sheet 0.5 mm
Gauge sheet
Rain water Gutter 7 mm
Ridge Cover (Approx 2.5 m long)
Flushing 4 side
Eave side Curve sheet
Gable Side Curve sheet

Workshop A
QUANTITY UNIT

RATE
(AED)

AMOUNT
(AED)

236,641
29,724

kg
kg

9
8

2,678

m2

150

401,625

154
154
224
77
35

m
m
m
m
m

150
150
100
150
150

23,100
23,100
22,400
11,550
5,250

TOTAL (AED)

REMARKS

2,129,768
237,790

2,854,583 /-

1,066

AL YARMOUK STEEL & ENGG. CO LLC


P.O BOX. 4952 AJMAN, UAE.
E-mail: yarmoukstl@gmail.com/ yarmouk2@eim.ae

THERMOSORB PAINT THICKNESS AS PER LOADING CHART


Project: Tawam Dialysis Center (B+G+1 Building) Al Ain, UAE
Location: Al Ain, UAE
Client : Abu Dhabi Health Service Company (SEHA)
Consultant: Burt, Hill (BH)
Civil Contructor: Civil Power Contracting (Cpc)
SL No.

Ref

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

STB1
STB2
STB3
STB4
STB5
STB6
STB7
STB8
STB10
STB8'
STB10'
SC1
SC2
SC4
SC7
FSC3
ST 09
ST 09

Item Description
UB 254x254x89
UB 254x254x73
UC 203X203X46
UC203X203X86
UC152X152X37
UC254X254X167
UC152X152X23
UB127X76X13
UC 152x89x16
UC152X152X23
UC203X203X46
CHS 273x10
UC 203X203X46
UB 254x254x73
RHS 150x100x5
UC 152x152x37
RHS 150x100x4
RHS 80x40x4

Thermosorb Paint
Thickness ( Microns)

Remarks

THERMOSORB PAINT THICKNESS AS PER LOADING CHART


Project: Tawam Dialysis Center (B+G+1 Building) Al Ain, UAE
Location: Al Ain, UAE
Client : Abu Dhabi Health Service Company (SEHA)
Consultant: Burt, Hill (BH)
Civil Contructor: Civil Power Contracting (Cpc)

As Per Loading Chart


SL No.

Ref

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

STB1
STB2
STB3
STB4
STB5
STB6
STB7
STB8
STB10
STB8'
STB10'
SC1
SC2
SC4
SC7
FSC3
ST 09
ST 09

Item Description
UB 254x254x89
UB 254x254x73
UC 203X203X46
UC203X203X86
UC152X152X37
UC254X254X167
UC152X152X23
UB127X76X13
UC 152x89x16
UC152X152X23
UC203X203X46
CHS 273x10
UC 203X203X46
UB 254x254x73
RHS 150x100x5
UC 152x152x37
RHS 150x100x4
RHS 80x40x4

HP/A
130
160
200
110
190
75
300
320
310
300
200
105
200
160
210
190
260
270

Paint
Thickness for Thickness for Thickness
(1 hr) in
1 hr fire
2 hr fire
rating in mm rating in mm microns

1.02
1.09
1.42
1.99
1.37
0.89
2.11
2.26
2.18
2.11
1.42
1.20
1.42
1.09
2.30
1.37
2.60
2.60

4.57
5.18
5.89
4.08
5.76
3.15
8.31
8.86
8.64
8.31
5.89
5.60
5.89
5.18
10.40
5.76
12.60
12.60

1,020
1,090
1,420
1,990
1,370
890
2,110
2,260
2,180
2,110
1,420
1,200
1,420
1,090
2,300
1,370
2,600
2,600

Paint
Thickness
(2 hr) in
microns

4,570
5,180
5,890
4,080
5,760
3,150
8,310
8,860
8,640
8,310
5,890
5,600
5,890
5,180
10,400
5,760
12,600
12,600

Remarks

Extrapolated
Extrapolated
Extrapolated
Extrapolated

Extrapolated
Extrapolated
Extrapolated
Extrapolated

Notes:
a

Calculations based on the requirements of UL Design No.X662, X661, and X660.

All data is taken from drawings/information received, as noted on the above schedule. The contractor should check the data for errors or ommisions.

No allowance has been made for site wastage or application over thickness, or for the surface areas of fillets, stiffeners or base-plates.

Please refer to Carboline technical literature for further information on application recommendations.

extrapolated - thickness that has been caculated on its nearest value as the HP/a (subj. for approval).

No test data for rods, plates, and rsa thus considered as I-section in the calculation. (subject for approval)

Disclaimer Notice:

The above quantities are based upon information provided. We recommend that you undertake a full measure of the steelwork prior to commencing
the contract. The information contained on this document is provided in good faith, and every reasonable effort is made to ensure that it is accurate
and up to date. Any person/ company relying on any of the information contained on this document or making any use of the information contained
herein, shall do so at its own risk. Stoncor Middleeast LLC hereby disclaims any liability and shall not be held liable for any damages including,
without limitation, direct, indirect or consequential, damages including loss of revenue, loss of profit, loss of opportunity or other loss. Accordingly, this
information is provided 'as is' without warranty of any kind. In no event shall Stoncor Middleeast LLC be liable for any damage arising, directly or
indirectly, from the use of the information contained on this document including damages arising from inaccuracies, omissions or errors.