Вы находитесь на странице: 1из 30

Next Generation Frame (NGF)

600 mm Product Family


Ordering Guide

Next Generation Frame 600 mm Products


Table of Contents

Frames
Fiber Main Distributing Frame (FMDF) ................................................................................................2
Front Facing Fiber Main Distributing Frame (F3MDF)..........................................................................3
Fiber Slim Rack ..................................................................................................................................4
Blocks
Fiber Termination Blocks (FTB) Unterminated......................................................................................5
Cable Clamping Kit ............................................................................................................................6
Fiber Termination Blocks Preterminated ..........................................................................................7-8
Fiber Combination Blocks (FCB) ....................................................................................................9-11
Sliding Adapter Packs ......................................................................................................................12
Mini Value-Added Modules (Mini VAMs) ..................................................................................13-21
Accessories
Fiber Optic Terminal Jumper Storage Bay ........................................................................................22
Equipment Bay ................................................................................................................................23
End Guard........................................................................................................................................24
Cable Clamp Kits ............................................................................................................................24
Rack Installation Kits ........................................................................................................................24
AC Outlet Kits..................................................................................................................................24
Ultra Physical Contact Fiber Optic Patch Cords ..........................................................................25-26
Index ..............................................................................................................................................27

6/03

852

Next Generation Frame 600 mm Products

Introduction ..................................................................................................................................1

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products

852

Next Generation Frame 600 mm Products

Introduction
Unprecedented growth in the telecommunications industry has driven wide-spread deployment of optical
fiber over the past few years. As a result, many service providers are finding that their existing fiber frames
and troughs are overflowing with large masses of optical fiber patch cords. In addition, the rapid
deployment of SONET/SDH, fiber in the loop and video initiatives has created the demand for increased
termination density at the fiber distributing frame. Service providers must build a sound network
infrastructure that will provide a solid base for delivering the new and enhanced broadband services
promised by the ever-advancing information superhighway.
What's Next?
It's clear that simply adding additional fiber frames to an existing FDF lineup is not the answer, as
conventional fiber frames allow only a small number of bays in a lineup before the horizontal trough
system becomes unmanageable. A more innovative fiber management plan is needed that will provide
unlimited expansion as well as alleviate jumper pile-up in the horizontal troughs.
With the introduction of its Next Generation Frame family of products, ADC offers the innovative solution
that service providers have been waiting for. Designed specifically to provide higher density while improving
fiber cable management, the Next Generation Frame product family allows for virtually unlimited growth.
Frames
ADC's Next Generation Frame product line has fiber frames designed to fit a variety of termination, splice,
and storage applications. Each frame option is designed with an emphasis on superior cable management
and ease of use, including features such as ample trough space for cable and jumpers, easy access to
connectors, and storage for jumpers. The frame sections are shipped from the factory fully equipped with
all cable management hardware including a built-in jumper storage panel.
Fiber Termination Blocks (FTB)
Fiber Termination Blocks (FTBs) are available with SC, FC, ST and E-2000 adapters in block configurations
of 48, 72 or 96 positions. Also, 144 position FTBs are available using LX.5 and LC adapters. FTBs utilize
sliding adapter packs to gain easy access to both the front and rear connectors. There is also a block
configuration available to accommodate Mini Value-Added Modules (Mini VAMs) for applications requiring
splitters or WDMs. FTBs can be ordered with or without IFC or outside plant cable.
Fiber Combination Blocks Blocks (FCB)
Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block.
The block occupies two mounting positions on the frame section. They are available with SC, FC, ST and
E-2000 adapters in block configurations of 48, 72 or 96 positions. Also, 144 position FCBs are available
using LX.5 or LC adapters.

Features and Benefits


Ample Trough Space

Sliding Adapter Packs

Reduces jumper pile-up and congestion


- Reduces maintenance time due to easy removal
and tracing of jumpers
- Minimizes risk of microbends or damage to fiber

Promotes high density


Provides easy access to connectors
- Saves valuable floor space
- Reduces time required for operations and
maintenance

6/03

Built-in Jumper Storage Panel


Minimizes number of required jumper lengths
Maintains fiber bend radius
Simplifies frame installation
- Saves money by reducing the number of different
jumper lengths that have to be kept in inventory
- Minimizes risk of microbends or damage to fiber

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

Intelligent Cable Routing System


No fiber cross-over points
Multiple vertical troughways
- Reduces maintenance time due to easier
removal and tracing of jumpers and minimizes
fiber weaving

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products


The FMDF is the cornerstone of the NGF product line. This innovative frame has six rear horizontal
troughs. This abundant trough space minimizes fiber pile up and congestion leading to easier jumper
traceability and removal. The frame has twelve Fiber Termination Block (FTB) mounting positions equally
divided between vertical columns on the left and right sides of the frame as shown in the figure below.
The frame is 600 mm wide x 600 mm deep. The built-in jumper storage panel will store up to 5 meters
of jumper slack.
Left
Vertical

Right
Vertical
Horizontal
Trough (6)

Jumper
Storage
Panel

FTB
Mounting
Position
(12)

600 mm

Front ISO View

600 mm

Front View

Side View

Ordering Information
Description
600 mm FMDF Frame Section

Dimensions

Catalog Number

2.2 m x 600 mm x 600 mm

NGF-ETSIMDF6060

6/03

852

Next Generation Frame 600 mm Products

Fiber Main Distributing Frame (FMDF)

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products


The F3MDF is designed for single-sided access applications and may be mounted up against a wall or
back-to-back to save floor space. Unlike the FMDF, the more compact F3MDF is equipped with a single
230 mm horizontal trough. The F3MDF has twelve FTB mounting positions equally divided between
vertical columns on the left and right sides of the frame as shown in the figure below. The frame is
600 mm wide x 480 mm deep. The built-in jumper storage panel will store up to 5 meters of
jumper slack.
Left
Vertical
Jumper
Storage
Panel

Right
Vertical

FTB
Mounting
Position
(12)

2.2 m

Horizontal
Trough (6)

600 mm

Front ISO View

480 mm

Front View

Side View

Ordering Information
Description
600 mm F3MDF Frame Section

Dimensions

Catalog Number

2.2 m x 600 mm x 480 mm

NGF-ETSIF3MDF6048

3/03

852

Next Generation Frame 600 mm Products

Front Facing Fiber Main Distributing Frame (F3MDF)

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products


The Fiber Slim Rack is designed for lower density applications than the FMDF or F3MDF. It has six FTB
mounting positions and is designed for single-sided access applications. The Slim Rack is intended for
use in a single frame application and should not be used in a multiframe lineup. The built-in jumper
storage panel will store up to 5 meters of jumper slack.
When ordering FTBs for the Slim Rack, remember that only left oriented blocks are used on
this frame.
FTB
Mounting
Position

Jumper
Storage
Panel

2.14 m

480 mm

Front ISO View

480 mm

Front View

Side View

Ordering Information
Description
NGF Fiber Slim Rack Frame Section

Dimensions

Catalog Number

2.14 m x 480 mm x 480 mm

NGF-SLM7A100

3/03

852

Next Generation Frame 600 mm Products

Fiber Slim Rack

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products

Next Generation Frame 600 mm Products

Fiber Termination Blocks (FTB) Unterminated


FTBs without fiber can be ordered fully loaded with adapters or empty (no adapters), in which case the
adapter packs for the block must be ordered separately (see page 12). Before ordering, determine the
block orientation and cable exit direction. Unterminated FTBs may be ordered with a left orientation
(mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame).
The cable exit direction will be either upward (cables terminated to the rear side of the block exit up
toward the top of the frame) or downward (cables terminated to the rear side of the block exit down
toward the bottom of the frame). All blocks with adapters only are configured to terminate single or
dual jumpers on the rear of the block. If a multi-fiber breakout style cable (i.e., OSP/IFC) is to be
terminated to the rear of the block, a separate clamping kit is required (see page 6).

Catalog Number
NGF-TB
Block Style
Block Orientation

1 1 SC
2
3
4

3 L

FC/ST
E-2000
LX.5/LC

Left
Right

Adapter Type
Singlemode
7
8

Cable Exit Direction


Block Configuration

2 A 48

U
D

L
2
3

Upward
Downward

B 72
C 96
M 144 (LX.5 or LC only)*

Q
4
V
N

* 144 blocks using style 1, 2, or 3 cannot be used


in 26" wide NGF frames

X
K

Adapter Type
SC ultra polish
(62.5/125)
SC ultra polish,
Multimode
zirconia sleeve
SC 8 angled polish OR 9 SC
FC ultra polish
A FC
FC ultra polish,
5 ST
zirconia sleeve
Y LX.5
FC 8 angled polish
(144 only)
ST ultra polish
P LC
E-2000 angled polish
(144 only)
LX.5 ultra polish
(144 only)
LX.5 angled polish
(144 only)
LC ultra polish
(144 only)

Block Style
General adapter type required in the FTB

Block Configuration
Maximum number of terminations that the FTB will accommodate when fully loaded

Block Orientation
Vertical column of the frame the FTB is to be mounted on

Cable Exit Direction


Direction the equipment jumpers or OSP cable will exit from the FTB

Adapter Type
Specific adapter type required in the FTB

6/03

852

Definition of Variables

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products


Cable Clamping Kit
Clamping kit includes: Cable clamp, protective cover and fanout bracket. It is required when terminating
a multifiber breakout style cable to the rear of the block.
Protective
Cover

Fanout
Bracket

72 position block loaded


with jumpers

72 position block loaded with


multifiber breakout cable

72 position block with


clamping kit

Ordering Information
Description

Catalog Number

Block style originally purchased


All 48- and 72-position blocks
96-position blocks with rear cable management
as shown above (blocks ordered before June 2002
96- or 144-position Left Up Blocks
96- or 144-position Right Up Blocks
96- or 144-position Left Down Blocks
96- or 144-position Right Down Blocks

NGF-ACCOSPKIT02
NGF-ACCOSPKIT01
NGF-ACCRCMSLU
NGF-ACCRCMSRU
NGF-ACCRCMSLD
NGF-ACCRCMSRD

Rear Cable Management Tray


for 144 Block Conversion Kit

6/03

852

Next Generation Frame 600 mm Products

Fiber Termination Blocks

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products


Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or stranded
configurations. All blocks are 100% factory tested to guarantee continuity and reliable connections.
Preterminated FTBs make installation quick and easy, reducing labor costs. Before ordering, determine
the block orientation and cable exit direction. Preterminated FTBs may be ordered with a left
orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of
the frame). The cable exit direction will be either upward (cables terminated to the rear side of the
block exit up toward the top of the frame) or downward (cables terminated to the rear side of the
block exit down toward the bottom of the frame).

Preterminated Fiber
Termination Blocks
arrive from the factory
with either IFC or
OSP Cables

Fiber cable easily uncoils


during installation

Fiber Termination Block


ships inside the drum

Fiber Termination Block


loaded with multifiber
breakout cable

Ordering information follows on next page.

Block Style
General adapter type required in the FTB

Block Configuration
Maximum number of terminations that the FTB will accommodate when fully loaded

Block Orientation
Vertical column of the frame the FTB is to be mounted on

Cable Exit Direction


Direction the equipment jumpers or OSP cable will exit from the FTB

Adapter/Connector #1
Specific adapter/connector type required in the FTB. Refers to the adapter/
connector type at the FTB

Connector #2
Specific connector type required at the cable end opposite the FTB

Cable Type
Type of cable to be terminated to the FTB

Cable Length
Required length of the cable terminated to the FTB

6/03

852

Definition of Variables

Next Generation Frame 600 mm Products

Fiber Termination Blocks (FTB) Preterminated

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products


Preterminated FTBs

NGF-TB
Cable Length

8 XXX Length in

Block Style

1
2
3
4

meters

Adapter Type
Singlemode

SC
FC/ST
E-2000
LX.5/LC

Block Configuration

A
B
C
M

7
8
L
2
3

48
72
96
144 (LX.5 or
LC only)**

Q
4
V
N
X

Block Orientation

L
R

Left
Right

IFC Type Singlemode

7 ZB

SC ultra polish
SC ultra polish,
zirconia sleeve
SC 8 angled polish
FC ultra polish
FC ultra polish,
zirconia sleeve
FC 8 angled polish
ST ultra polish
E-2000 angled polish
LX.5 ultra polish
(144 only)
LX.5 angled polish
(144 only)
LC ultra polish
(144 only)

ZC
ZD
AA
BA
CA
2A
7A
VA
DA
FH
GA
HA
MA
JA
KA
EG
FJ
KB
EF
FK

OR

Adapter/Connector #1
Multimode (62.5/125)

Cable Exit Direction

4 U Upward
D

9
A
5
Y
P

Downward

SC
FC
ST
LX.5 (144 only)
LC (144 only)

0
7
8
L
2
3
Q
4
V
N
X
K

No connector/stub end
SC ultra polish
SC ultra polish, zirconia sleeve
SC 8 angled polish
FC ultra polish
FC ultra polish, zirconia sleeve
FC 8 angled polish
ST ultra polish
E-2000 angled polish
LX.5 ultra polish (144 only)
LX.5 angled polish (144 only)
LC ultra polish (144 only)

Connector #2
Multimode (62.5/125)

6/03

0
9
A
5
Y
P

72 fiber stranded
96 fiber stranded
144 fiber stranded
12 fiber stranded
24 fiber stranded
36 fiber stranded
48 fiber stranded
54 fiber stranded
72 fiber stranded
96 fiber stranded
144 fiber stranded
12 fiber ribbon
24 fiber ribbon
36 fiber ribbon
48 fiber ribbon
72 fiber ribbon
96 fiber ribbon
144 fiber ribbon
72 fiber ribbon
96 fiber ribbon
144 fiber ribbon

Glass Type
House Cable*
House Cable*
House Cable*
Corning
Corning
Corning
Corning
Corning
Corning
Corning
Corning
Sumitomo
Sumitomo
Sumitomo
Sumitomo
Sumitomo
Sumitomo
Sumitomo
Alcatel
Alcatel
Alcatel

OR

Connector #2 Singlemode

852

Next Generation Frame 600 mm Products

Catalog Number

OR

IFC Type Multimode


(62.5/125)
AM 12 fiber stranded
BM 24 fiber stranded
DM 36 fiber stranded
2M 48 fiber stranded
VM 72 fiber stranded
WM 96 fiber stranded

Glass Type
Corning
Corning
Corning
Corning
Corning
Corning

OSP Cable Type Singlemode


VP
VT
VU
VW
EN
FL
FM

OR

72 fiber ribbon dielectric


72 fiber stranded dielectric
96 fiber ribbon dielectric
96 fiber ribbon dielectric
96 fiber stranded dielectric
144 fiber stranded dielectric
144 fiber ribbon dielectric

Glass Type
Alcatel
Pirelli
Alcatel
Pirelli
Pirelli
Pirelli
Pirelli

Other cable types are available upon request.


Please contact your ACD representative.

No connector/stub end
SC
FC
ST
LX.5 (144 only)
LC (144 only)

* House cable will use Corning SMF28, Sumitomo,


Alcatel or similar singlemode fiber based on current
market availability.
** 144 blocks using style 1, 2, or 3 cannot be used
in 26" wide NGF frames

See previous page for definition of variables.


w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products


Fiber Combination Blocks provide a place to terminate pigtails and splice IFC/OSP cables on the frame.
The blocks are available with several different adapter types in block configurations of 48, 72, or 96
positions. Also, a 144 position FCB is available using an LX.5 adapter. The termination portion of the
fiber combination block utilizes sliding adapter packs to gain easy access to connectors on both the front
and rear side of the block. The block is available with factory-installed pigtails for easy installation. Splice
trays are shipped with the block if ordered with pigtails; otherwise trays must be ordered separately. The
block is shipped with a cable clamp for OSP/IFC. The FCB occupies two mounting positions on a frame
section. Before ordering, determine the block orientation. FCBs may be ordered with a left orientation
(mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame).

Ordering information follows on next page.

6/03

852

Next Generation Frame 600 mm Products

Fiber Combination Blocks (FCB)

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Next Generation Frame 600 mm Products


Catalog Number
NGF-CB

6/03

Pigtail Type
Adapter Type
Singlemode

44
Block Style
1 1 SC
2 FC/ST
3 E-2000
4 LX.5 /LC
Block Configuration
2 A 48
B 72
C 96
M 144 (LX.5 or LC only) 1

7
8

SC ultra polish
SC ultra polish,
zirconia sleeve
L SC 8 angled polish
2 FC ultra polish
3 FC ultra polish,
zirconia sleeve
Q FC 8 angled polish
4 ST ultra polish
V E-2000 angled polish
N LX.5 ultra polish (144 only)
X LX.5 angled polish
(144 only)
K LC ultra polish (144 only)

No pigtails
12 fiber pigtail
12 fiber stranded
Maxi-Strip
8 fiber pigtail
12 fiber ribbon

Number of Pigtail
Assemblies

6 XX Number of assemblies
Splice Chip

OR

A
5
9
Y
P

0
1
2
4
5

Adapter/Connector Type
Multimode (62.5/125)

Block Orientation
3 L Left
R Right

FC
ST
SC
LX.5 (144 only)
LC (144 only)

0
1
2
3
6
7
8
9
4

Empty
Bare fusion
Heat shrink fusion
Mechanical (elastomeric)
Nortel QPAK
Swiss ANT
Rotary
FibrLok
16 position heat shrink fusion

144 termination block requires the use of either:


Mechanical (elastomeric) splice tray when using mass fusion ribbon splicing
Nortel QPAK splice tray when using single fiber heat shrink fusion splicing
144 blocks using block style 1, 2, or 3 cannot be used in 26" wide NGF frames
1

Definition of Variables
1

Block Style
General adapter type required in the FCB

Block Configuration
Maximum number of terminations that the FCB will accommodate when fully loaded

Block Orientation
Vertical column of the frame the FCB is to be mounted on

Adapter/Connector Type
Specific adapter/connector type required in the FCB

Pigtail Type
Type of pigtail required

Number of Pigtail Assemblies


Number of pigtails to be pre-installed in the FCB

Splice Chip
Type of splice chip required for splice trays

852

Next Generation Frame 600 mm Products

Fiber Combination Blocks (FCB)

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

10

Next Generation Frame 600 mm Products


Splice Trays For Fiber Combination Block

FST - DRS

Splice Tray Type


Number of Splices

1 12
24

2 00

12 splices
24 splices

Note: For LX.5 FCB with 12 fiber ribbon


pigtails, select mechanical splicing only.
For LX.5 FCB with 12 fiber stranded pigtails
select Nortel QPAK (compatible with heat
shrink fusion), bare fusion or Swiss ANT only.

FT
HS
MT
NT
ANT
RT
3M

Empty tray*
Bare fusion
Heat shrink fusion
Mechanical (elastomeric)
Nortel QPAK
Swiss ANT
Rotary
FibrLok

* Maximum size of chip allowed in


empty tray: .3"H x 2.5"W x 3.6"L

6/03

852

Next Generation Frame 600 mm Products

Catalog Number

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

11

Next Generation Frames

Next Generation Frame 600 mm Products

Sliding Adapter Packs

Sliding adapter packs house groups of fiber optic adapters and are mounted in Fiber Termination Blocks to
provide easy access to connectors. Sliding Adapter Packs are available with SC, FC, ST, E-2000 and LX.5
adapters. The adapters come in packs of two, four, six and eight depending on the adapter type and the
desired termination density. See table below for configuration guidelines.
* Sliding Adapter Pack Configuration Guidelines
Block
Configuration

Adapter Type

48-Position
72-Position
72-Position
96-Position
96-Position
96-Position
144-Position (block code'E')
144-Position (block code'M')

SC, FC, ST, E-2000


SC, E-2000
FC, ST
SC, E-2000
FC, ST
SC, FC, ST, E-2000
LX.5
SC, FC, E-2000, LX.5, LC

Option A
(SC shown)

852

2 Pack /
2 Pack /
6 Pack
2 Pack /
8 Pack
4 Pack /
12 Pack
6 Pack /

2 Pack
4 Pack
6 Pack
4 Pack
6 Pack

Option F
(E-2000 shown)

Option E
(ST shown)

Adapter Pack
Option
B (shown below)
A (shown below)
E (shown below)
F (shown below)
G (shown below)
J (not shown below)
H (not shown below)
K (not shown below)

Option G
(FC shown)

Option H
(LX.5 only)

Catalog Number
NGF- SAP

Adapter Type
Singlemode

6/03

Option B
(FC shown)

Adapter Pack
Configuration

7
8
L
2
3
Q
4
V
N
X
K

Adapter Pack Option*

SC ultra polish
Adapter Type
SC ultra polish,zirconia sleeve
Multimode
SC 8 angled polish
SC
9
FC ultra polish
OR
A FC
FC ultra polish, zirconia sleeve
ST
5
FC 8 angled polish

LX.5
Y
ST ultra polish
(144 only)
E-2000 angled polish
LX.5 ultra polish (144 only)
LX.5 angled polish (144 only)
LC ultra polish (144 only)

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

A
B
E
F
G
H
J
K

2 pack/4 pack
2 pack/2 pack
6 pack
2 pack/6 pack
8 pack
12 pack (LX.5 block
code "E" only)
4 pack / 4 pack
6 pack / 6 pack
(all block code "M" blocks)

1 - 8 0 0 - 3 6 6 - 3 8 9 1

12

Next Generation Frames


ADCs Next Generation Frame (NGF) Value-Added
Modules are designed to support emerging circuit
requirements. This high-density fiber frame
solution provides unlimited expansion while
optimizing fiber cable management. The NGF
system uses Mini Value-Added Modules to
incorporate optical splitters for circuit monitoring
and video distribution. Mini Value-Added Modules
can also be configured with wavelength division
multiplexing capabilities to increase transmission
capacity over existing fiber lines. Various input
and output interface options are available.

6/03

Features:

Enclosed plug-in modules


Optical components are protected from
physical and environmental damage

Flexible platform
Modules can be created for new applications
quickly and easily to meet customer
requirements

Monitor and/or test


Enables providers to troubleshoot networks
without forcing disruption of service

Custom configurations
Custom splitter configurations available
upon request

VAM Chassis
The NGF VAM chassis is designed to mount
on all standard NGF frame styles and is
interchangeable with termination, splice, and
storage modules. Each chassis accommodates
up to twelve Mini-VAM modules.

NGF VAM Chassis

Catalog Number
NGF - TB
Block Style
1
SC
2
FC/ST
3
E-2000

D
Cable Exit Direction (Rear)
Upward
U
D
Downward
Block Orientation
L
Left
R
Right

852

Next Generation Frame 600 mm Products

Value-Added Module System

* NGF VAMs with LX.5 or LC adapters can be placed in any of these block styles.
Please contact ADC Technical Assistance Center at 1-800-366-3891 with any questions.

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

13

Next Generation Frames

Next Generation Frame 600 mm Products

Value-Added Module System


Video Splitter Module Ordering Information
Catalog Number
NGF-V__ __ __ __ __ __ __ __ __ __ __ __ __ __ __
Module Option
2 Input front, output front
5 Input rear, output front

Split Ratio
2000
1x2
2100
1x2
2200
1x2
2300
1x2
2350
1x2
2400
1x2
2500
1x2
2600
1x2
2700
1x2
2800
1x2
2900
1x2
2950
1x2
2030
1x2
3900
1x3
4900
1x4
5300
1x5
6000
1x6

Input Connector/Adapter
Singlemode
2U FC ultra polish
2A FC angled polish
7U SC ultra polish
7A SC angled polish
4U ST ultra polish
8A E-2000 angled polish
LU LX.5 ultra polish
LA LX.5 angled polish
KU LC ultra polish
00 Bare fiber
or
Multimode**
2M FC 62.5/125
2N FC 50/125
9A SC 50/125
9B SC 62.5/125
5F
ST 50/125
5U ST 62.5/125
LM LX.5
PM LC
00 Bare fiber

7000

1x7

8000

1x8

50/50
55/45
60/40
65/35
66.6/33.3
70/30
75/25
80/20
85/15
90/10
95/5
99/1
50/50
33/33/33
25/25/25/25
20/20/20/20/20
16.6/16.6/16.6
16/6/16.6/16.6
14.3/14.3/14.3/14.3
14.3/14.3/14.3
12.5/12.5/...12.5

Output Connector/Adapter
Singlemode
2U FC ultra polish
Multimode**
2A FC angled polish
2M FC 62.5/125
7U SC ultra polish
or
2N FC 50/125
7A SC angled polish
9A SC 50/125
4U ST ultra polish
9B SC 62.5/125
8A E-2000 angled polish
5F
ST 50/125
LU LX.5 ultra polish

5U
ST
62.5/125
LA LX.5 angled polish
LM LX.5
KU LC ultra polish
PM LC
00 Bare fiber
00 Bare fiber

Splitter Type
LEAVE Wideband 1310 and
BLANK 1550 nm
G 1310 nm wavelength
flattened
J
1550 nm wavelength
flattened
Output Pigtail
Length (in meters)
Example:
00 = No pigtail
01 = 1 meter
10 = 10 meters
Input Pigtail
Length (in meters)
Example:
00 = No pigtail
01 = 1 meter
10 = 10 meters
Leave 00 for
adapter option

Number of Splitters
A Single splitter
B Dual splitter
C Triple splitter

REAR

Input Front,
Output Front
REAR

FRONT

4
FRONT

OUT
OUT
IN

852

Output Front

INPUT

6/03

IN

OUT
1xN

INPUT
OUTPUT
OUTPUT

**Contact ADC for multimode specifications


and available split ratios

OUT
1xN

Other split ratios are available.


Call ADC Technical Assistance Center
at 1-800-366-3891.

OUTPUT
OUTPUT

OUTPUT
OUTPUT

INPUT

Input Rear,
Output Front

w w w. a d c . c o m

Input Front,
Output Rear

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

14

Next Generation Frames


Singlemode Wideband Optical Splitter Specifications
Other splitter configurations are available. Please call ADC Technical Assistance Center,
1-800-366-3891.
Splitter
Number

Splitter
Type

2000
2100
2200
2300
2350
2400
2500
2600
2700
2800
2900
2950
2030
3900
4900
5300
6000
7000
8000
9000
A110
B111
C112
D113
E114
F115
G116
M132

1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
2x2
1x3
1x4
1x5
1x6
1x7
1x8
1x9
1x10
1x11
1x12
1x13
1x14
1x15
1x16
1x32

Splitter
Ratio
50/50
55/45
60/40
65/35
66.6./33.3
70/30
75/25
80/20
85/15
90/10
95/5
99/1
50/50
33/33/33
25/25/25/25
20/20/20/20/20
16.6/16.6/ . . . 16.6
14.3/14.3/ . . . /14.3
12.5/12.5/ . . .12.5
11.1/11.1/ . . . /11.1
10/10/10 . . . /10
9.1/9.1/ . . . /9.1
8.3/8.3/ . . . /8.3
7.7/7.7/ . . . /7.7
7.14/7.14/ . . . /7.14
6.66/6.66/ . . . /6.66
6.25/6.25/ . . . 6.25
3.13/3.13/ . . . 3.13

Maximum
Insertion Loss*
3.7/3.7
3.2/4.1
2.7/4.7
2.3/5.3
2.2/5.5
2.0/6.0
1.6/6.8
1.3/7.8
1.0/9.2
.8/11.2
.5/14.4
0.3/22.5
3.7/3.7
5.9/5.9/5.9
7.4/7.4/7.4/7.4
8.6/8.6/8.6/8.6/8.6
9.8/9.8/9.8/ . . ./9.8
10.6/10.6/ . . . /10.6
11.3/11.3/ . . . /11.3
11.5/11.5/ . . . /11.5
12.1/12.1/ . . . /12.1
13.1/13.1/ . . . /13.1
13.3/13.3/ . . . /13.3
13.8/13.8/ . . . /13.8
13.8/13.8/ . . . /13.8
14.5/14.5/ . . . /14.5
14.9/14.9/ . . . 14.9
18.5/18.5/ . . . 18/5

Typical
Insertion Loss*
3.1/3.1
2.7/3.6
2.3/4.1
2.0/4.7
1.9/5.0
1.7/5.4
1.4/6.2
1.1/7.1
.8/8.4
.6/10.2
.4/13.2
NA/NA
3.1/3.1
5.0/5.0/5.0
6.2/6.2/6.2/6.2
7.3/7.3/7.3/7.3/7.3
8.1/8.1/8.1 . . . /8.1
8.9/8.9/ . . . /8.9
9.5/9.5/ . . ./9.5
9.9/9.9/ . . . /9.9
10.4/10.4/ . . . /10.4
10.9/10.9/ . . . /10.9
11.3/11.3/ . . . /11.3
11.6/11.6/ . . . /11.6
11.8/11.8/ . . . /11.8
12.4/12.4/ . . . /12.4
12.6/12.6/ . . . 12.6
15.8/15.8/ . . . 15.8

* Does not include connector loss. See table on the following page or call ADC Technical Assistance Center,
1-800-366-3891.

Maximum Insertion Loss


Maximum insertion loss is the upper limit of insertion loss for the coupler and applies over the entire
wavelength range specified in the bandpass.
Typical Insertion Loss
Typical insertion loss is the expected insertion loss value for the coupler measured at the specified center
wavelength (i.e., 1310 nm and/or 1550 nm).

6/03

852

Next Generation Frame 600 mm Products

Value-Added Module System

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

15

Next Generation Frames


Singlemode Optical Splitter Specifications
MATERIAL
Fiber:
Jacket:
Housing:

Corning SMF-28
0.900 mm hytrel tube
Stainless steel tube

OPTICAL
Bandpass
Wavelength 1:
Wavelength 2:
Directivity:
Reflectance:
Polarization Stability:

1260/1360 nm
1430/1580 nm
55 dB minimum
< -55 dB
.5 dB maximum

MECHANICAL
Cable Retention:

.45 kg (1.0 lb.) maximum for .25 mm and .900 mm fiber,


1 kg (2.2 lbs.) maximum for cabled fiber assemblies
300 cycles; .45 kg (1.0 lb.) maximum load (fiber cable only)
100 cycles; .45 kg (1.0 lb.) maximum load (fiber cable only)
10-55 Hz per FOTP II condition I
8 drops from 1.5 meters
All materials used in fabrication of coupler housing meet
UL 94, Level V-I requirements

Flex:
Twist:
Vibration:
Impact:
Flammability:
ENVIRONMENTAL
Humidity:
Thermal Aging:
Temperature Cycling:

336 hours, 60C at 95% relative humidity


336 hours, 85C
336 hours, -40C to 85C

Singlemode Optical Connector Specifications


INSERTION LOSS
(dB)

RETURN LOSS
(dB)

Ultra Polish
PC Connectors:

0.3 dB maximum
0.15 dB typical

57 dB minimum

Angled Polish
Connectors:

0.5 dB maximum
0.2 dB typical

65 dB minimum

6/03

852

Next Generation Frame 600 mm Products

Value-Added Module System

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

16

Next Generation Frames

852

Next Generation Frame 600 mm Products

Value-Added Module System


WDM Module Ordering Information
Catalog Number
NGF-W__ __ __ __ __ __ __ __ __ __ __ __ __
Configuration
2 MUX front, DEMUX front
5 MUX rear, DEMUX front
Mux Port
Connector/Adapter
2U FC ultra polish
2A FC angled polish
4U ST ultra polish
7U SC ultra polish
7A SC angled polish
8A E-2000 angled polish
LU LX.5 ultra polish
LA LX.5 angled polish
KU LC ultra polish
00 Bare fiber

WDM Type ( , )
A Undirectional multiplexer
C Undirectional demultiplexer
E Bidirectional Tx/ Rx
G Bidirectional Rx/ Tx
J
45 dB isolation, pass 1310
K 45 dB isolation, pass 1550
L (Dual only) unidirectional
multiplexer, undirectional
demultiplexer*
M (Dual only) bidirectional
Tx/ Rx, bidirectional
Tx/ Rx
1

Demux Port
Connector/Adapter
2U FC ultra polish
2A FC angled polish
4U ST ultra polish
7U SC ultra polish
7A SC angled polish
8A E-2000 angled polish
LU LX.5 ultra polish
LA LX.5 angled polish
KU LC ultra polish
00 Bare fiber

* WDM Type "L" includes


(1) unidirectional multiplexer
(standard isolation) and
(1) unidirectional demultiplexer
(isolation specified by next character)

Mux Port
Pigtail Length
Length (in meters)
Example:
00 = No pigtail
01 = 1 meter
10 = 10 meters
Leave 00 for
adapter option

Wavelength
A 1310 ( )/1550( )
B 1533 ( )/1557( )
E 1550 ( )/1625( )
F
1310 ( )/1625( )
1

Isolation
1
2
3

Standard
High
Very high

In the ordering charts, the abbreviation mux references the multiplexed


side of the WDM, the side where two optical signals coexist on one fiber.
The abbreviation demux references the demultiplexed side of the WDM,
the side where each signal appears on its own fiber. Both unidirectional
and bidirectional WDMs are available as shown below.
UNIDIRECTIONAL MULTIPLEXER
1310

Demux Port
Pigtail Length
Length (in meters)
Example:
00 = No pigtail
01 = 1 meter
10 = 10 meters

Module
Configuration
A Single
B Dual
C Triple

UNIDIRECTIONAL DEMULTIPLEXER
1310 1550

1310 1550

DEMUX

MUX

MUX

BIDIRECTIONAL TRANSMISSION

1310
DEMUX

1310

1550

6/03

1550

1310 1550

DEMUX

MUX
1550
1310

1310 1550
MUX

DEMUX
1550

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

17

Next Generation Frames


WDM Module

Mux Front,
Demux Front
REAR

5
FRONT

REAR

Demux
Demux

WDM

Mux Rear,
Demux Front

Mux

FRONT

WDM

Demux
Demux

Mux

6/03

852

Next Generation Frame 600 mm Products

Value-Added Module System

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

18

Next Generation Frames

6/03

852

Next Generation Frame 600 mm Products

Value-Added Module System


Singlemode WDM Specifications
MATERIAL
Fiber:
Jacket:

Corning SMF-28
0.900 mm

OPTICAL
Uniformity:
Polarization Stability:
Bandpass:
Insertion Loss:
Reflectance:
Isolation
Near End:
Far End:

1.0 Log2N (where N = number of channels)


0.5 dB maximum
(see table below)
(see table below)
< -55 dB
55 dB
(see table below)

MECHANICAL
Cable Retention:

.45 kg (1.0 lb.) maximum for .250 mm and .900 mm fiber;


1.0 kg (2.2 lbs.) maximum for cabled fiber assemblies
300 cycles; .45 kg (1.0 lb.) maximum load (fiber cable only)
100 cycles; .45 kg (1.0 lb.) maximum load (fiber cable only)
10-55 Hz per FOTP II condition I
8 drops from 1.5 meters
All materials used in fabrication of the coupler housing meet UL 94,
Level V-I requirements

Flex:
Twist:
Vibration:
Impact:
Flammability:
ENVIRONMENTAL
Humidity Resistance:
Thermal Aging:
Temperature Cycling:

336 hours, 60C at 95% relative humidity


336 hours, 85C
336 hours, -40C to 85C

1310/1550 nm

MAXIMUM INSERTION LOSS* MINIMUM ISOLATION


(dB)
(dB)

PASSBAND
(nm)

Multiplexer/Demultiplexer:
High Isolation Demultiplexer:
Very High Isolation
Demultiplexer:
Wavelength Filters:

1310 20 nm and 1550 20 nm


1310 20 nm and 1550 20 nm

0.3
0.7

15
30

1310 20 nm and 1550 20 nm


1310 20 nm and 1550 20 nm

1.0
0.3

45
15

1533/1557 nm

Unidirectional Multiplexer:
High Isolation
Undirectional Multiplexer
or Bidirectional
Multiplexer/Demultiplexer:
Very High Isolation
Undirectional Multiplexer
or Bidirectional
Multiplexer/Demultiplexer:
Filter Passing 1533 nm:
Filter Passing 1557 nm:

PASSBAND
(nm)

MAXIMUM INSERTION LOSS*


(dB)

MINIMUM ISOLATION
(dB)

1533 3 and 1557 3 nm

0.9

N/A

1533 3 and 1557 3 nm

1.8

20

1533 3 and 1557 3 nm


1533 3 nm
1557 3 nm

2.1
0.9
0.9

35
13
13

* Maximum Insertion Loss does not include connector loss. See pages 15-16 for connector
specifications and definitions.

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

19

Next Generation Frames

6/03

852

Next Generation Frame 600 mm Products

Value-Added Module System


Monitor Module Ordering Information
Catalog Number
NGF-M__ __ __ __ __ __ __ __ __

Input Connector/Adapter
Singlemode
2U FC ultra polish
2A FC angled polish
7U SC ultra polish
7A SC angled polish
4U ST ultra polish
8A E-2000 angled polish
LU LX.5 ultra polish
LA LX.5 angled polish
KU LC ultra polish
00 Bare fiber
or
Multimode**
2M FC 62.5/125
2N FC 50/125
9A SC 50/125
9B SC 62.5/125
5F
ST 50/125
5U ST 62.5/125
LM LX.5
PM LC
00 Bare fiber
Output Connector/Adapter
Singlemode
2U FC ultra polish
2A FC angled polish
7U SC ultra polish
7A SC angled polish
4U ST ultra polish
8A E-2000 angled polish
LU LX.5 ultra polish
LA LX.5 angled polish
KU LC ultra polish
00 Bare fiber
or
Multimode**
2M FC 62.5/125
2N FC 50/125
9A SC 50/125
9B SC 62.5/125
5F
ST 50/125
5U ST 62.5/125
LM LX.5
PM LC
00 Bare fiber

w w w. a d c . c o m

Monitor Pigtail Length

Number of Circuits
per VAM
1 1 circuit
2 2 circuits
3 3 circuits
Split
A
B
C
E
F
H
J
K

Output Pigtail Length


Input Pigtail Length
Length (in meters)
Example:
00 = No pigtail
01 = 1 meter
10 = 10 meters

Ratio
90/10
95/05
50/50
80/20
75/25
70/30
60/40
99/01

Leave 000 for


adapter option

Monitor Connector Type


Singlemode
2U FC ultra polish
2A FC angled polish
7U SC ultra polish
7A SC angled polish
4U ST ultra polish
8A E-2000 angled polish
LU LX.5 ultra polish
LA LX.5 angled polish
KU LC ultra polish
00 Bare fiber

Module Style
B
Cross-connect customer
premises
D
Dual monitor cross-connect
G
Dual monitor cross-connect
J
Dual monitor
P
Customer premises
R
Single monitor cross-connect
* See detailed splitter and connector
specifications on pages 19-20.
Contact ADC for multimode
specifications and available split ratios
at 1-800-366-3891.

or
Multimode**
2M FC 62.5/125
2N FC 50/125
9A SC 50/125
9B SC 62.5/125
5F
ST 50/125
5U ST 62.5/125
LM LX.5
PM LC
00 Bare fiber

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

20

Next Generation Frames


Monitor Module
Mon tor Modu e

Cross Connect

Cross Connect

XX%

1x2
SPLITTER B

XX%

CUST MON
Tx
SRC MON

XX%

1x2
SPLITTER A

10%
SPLITTER

SRC Rx

90%

XX%

90%

Rx MON

Tx Mon
Tx

1x2

Rx

SPLITTER

CUST Tx

Tx
Tx
Rx

SRC Tx

Dual Monitor
Cross-Connect

1x2

Rx Mon

Tx MON

10%

CUST Rx

1x2

Rx

Rx

Customer Premises
Monitor Module

Single Monitor
Cross-Connect

Mon Tx
Mon Rx

XX.XX%

CUST
MON

1x2
SPLITTER

XX.XX%

CUST Rx
CUST Tx

XX.XX%

Tx
AI

1x2
SPLITTER
XX.XX%

Tx
SRC
MON

Rx
1x2

XX.XX%

1x2
SPLITTER
XX.XX%

Tx MON
A2

SRC Rx
Rx

Tx
A

SRC Tx

Tx SRC

Rx

Rx SRC

6/03

852

Next Generation Frame 600 mm Products

Value-Added Module System

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

21

Next Generation Frame 600 mm Products

2.2 m

300 mm

Front ISO View

600 mm

Front View
(NGF-ACCFOTSB300 Shown)

Side View

Ordering Information
Description

Catalog Number

Dimensions

FOT Storage Bay for 600 mm


FMDF Lineups

2.2 m x 300 mm x 600 mm

NGF-ACCFOTSB300

FOT Storage Bay for 600 mm


F3MDF Lineups (not shown)

2.2 m x 300 mm x 480 mm

NGF-F3ACCFOTSB300

6/03

852

Next Generation Frame 600 mm Products

Fiber Optic Terminal Jumper Storage Bay

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

22

Next Generation Frame 600 mm Products


The NGF Equipment Bay provides a mounting location for 19" rack
mount equipment within an FMDF lineup. The equipment deployment
in the bay can include video transmitters, RF Splitter/Combiners, or
Remote Fiber Test Systems. NGF Equipment Bays are available for
FMDF lineups (600 mm deep) and F3MDF lineups (480 mm deep).

2.2 m

600 mm
600 mm

NGF-ETSIEB6060-19

Ordering Information
Description

Catalog Number

Dimensions

Equipment Bay for FMDF lineups


For 19" equipment (maximum
equipment depth 48.26 cm)
(36) rack unit mounting spaces
available (EIA hole spacing)
Equipment Bays for
F3MDF lineups
For 19" equipment (maximum
equipment depth 48.26 cm)
(36) rack unit mounting spaces
available (EIA hole spacing)

2.2 m x 600 mm x 600 mm

NGF-ETSIEB6060-19

2.2 m x 600 mm x 480 mm

NGF-ETSIF3EB6048-19

6/03

852

Next Generation Frame 600 mm Products

Equipment Bay

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

23

Next Generation Frame 600 mm Products

6/03

852

Next Generation Frame 600 mm Products

Accessories
End Guard
The end guard provides protection for the fibers entering and exiting frames at the ends of a lineup.
Ordering Information
Description

Catalog Number

FMDF end guard, 600 mm deep


F3MDF end guard, 480 mm deep

NGF-ETSIACCEG
NGF-ETSIF3ACCEG

Cable Clamp Kits


Cable clamp kits are available for securing IFC/OSP cable or equipment (FOT) jumpers on the rear of the FTB.
Ordering Information
Description

Catalog Number

Cable clamp kit for FOT patch cords


included with fiber termination
blocks loaded with adapters only
Cable clamp kit for IFC/OSP cables
included with fiber termination
blocks with IFC

NGF-ACCCLMP04

NGF-ACCCLMP08

Rack Installation Kits


Ordering Information
Description

Catalog Number

Rack installation kit for concrete


floor, kit includes:
(2) M8 bolts, 90 mm
(4) M8 nuts
(8) flat washers
(4) lock washers
shims and anchor plates

RAC-MX0616

Rack installation kit for raised floor,


kit includes:
(4) threaded rods M12 x 1 m
(12) heavy nuts, lock and flat
washers
(4) nuts with springs, M12
(2) 1.8 m unistrut
(1) anchor kit

RAC-MX0615

AC Outlet Kits
Please contact your ADC representative for catalog numbers

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

24

Next Generation Frames

6/03

852

Next Generation Frame 600 mm Products

Patch Cords
Singlemode

Catalog Number
__ __ - __ - S - __ M

Cable Option
FPC Connector on both ends (patch cord)
FPT Connector on one end (pigtail)
Cable Type
Leave
3 mm single
Blank
M 2 mm single
F 1.7 mm single
9 900 micron
Z 3 mm dual zip
2 2 mm dual zip
T 1.7 mm dual zip
For hybrid patch cords, enter both connector types
in this field and separate them with a slash mark;
remove "S" from the ultra polish connector options
(see second ordering example).
2
One connector per end; requires dual zip cable
3
Requires 900 micron, 1.7 mm or 2 mm cable
4
Requires 1.7 mm or 2 mm dual zip cable
1

Length
X Length in meters

Connector Type1
SPSC SC ultra polish
APSC SC angled polish
SDSC SC duplex2
SPFC FC ultra polish
APFC FC angled polish
SPST ST ultra polish
AE2 E-2000 angled polish
SPLX LX.5 ultra polish3
ALX5 LX.5 angled polish3
SDLX LX.5 ultra polish duplex4
ADLX LX.5 angled polish duplex4
SPLC LC ultra polish
SDLC LC ultra polish duplex2

Ordering Example
FPC2-SPFC-10M: Patch cord with ultra polish FC connectors on both ends, 2 mm dual zip
cable, 10 meters in length with standard breakout length of 12" on both ends.
FPC-SPST/PSC-S-10M: Patch cord with ST ultra polish connector on one end and SC ultra
polish connector on the other end, 10 meters in length.

Multimode

Catalog Number
__ __ - __ - __ - __ M

Cable Option
FPC Connector on both ends (patch cord)
FPT Connector on one end (pigtail)
Cable Type
Leave
3 mm single
Blank
M 2 mm single
F 1.7 mm single
9 900 micron
Z 3 mm dual zip
2 2 mm dual zip
T 1.7 mm dual zip

X Length in meters

Fiber Size
A
B

For hybrid patch cords, enter both connector types


in this field and separate them with a slash mark
2
One connector per end; requires dual zip cable
3
Requires 900 micron, 1.7 mm or 2 mm cable
4
Requires 1.7 mm or 2 mm dual zip cable
1

Length

50/125
62.5/125

Connector Type1
MSC SC ultra polish
MDSC SC duplex2
MFC FC ultra polish
MST ST ultra polish
MLX5 LX.5 ultra polish3
MDLX LX.5 duplex4
MLC LC ultra polish
MDLC LC duplex2

Ordering Example
FPC-MST/MSC-B-7M: Patch cord with ST ultra polish connector on one end and SC
ultra polish connector on the other end, 62.5/125 fiber size, 7 meters in length.

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

25

Next Generation Frames


Standard Cross-Connect Patch Cord Lengths
Total Number of Sections
Traversed

Same frame
Adjacent frames
3 to 4
5 to 6
7 to 8
9 to 10

Patch Cord Length


(approximate)
Feet

Meters

18
23
26
33
36
39

6.0
7.0
8.0
10.0
11.0
12.0

*Depending on office requirements, 11 or more frame sections may require the use of interbay tie panels.
For additional information, please call ADC Technical Assistance Center, 1-800-366-3891.

6/03

852

Next Generation Frame 600 mm Products

Cable Assemblies

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

26

Next Generation Frame 600 mm Products


N
NGF-ACCCLMP04 ..................................................24
NGF-ACCCLMP08 ..................................................24
NGF-ACCFOTSB300 ..............................................22
NGF-ACCOSPKIT01 ..................................................6
NGF-ACCOSPKIT02 ..................................................6
NGF-ETSIACCEG ....................................................24
NGF-ETSIF3ACCEG ................................................24
NGF-ETSIEB6060-19 ..............................................23
NGF-ETSIF3EB6048-19 ..........................................23
NGF-ETSIF3MDF6048 ..............................................3
NGF-ETSIMDF6060 ..................................................2
NGF-F3ACCFOTSB300............................................22
NGF-SLM7A100 ......................................................4
R
RAC-MX0615 ........................................................24
RAC-MX0616 ........................................................24

6/03

852

Next Generation Frame 600 mm Products

Index

w w w. a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

27

Web Site: www.adc.com


From North America, Call Toll Free: 1-800-366-3891 Outside of North America: +1-952-938-8080 Fax: +1-952-917-3237
For a listing of ADCs global sales office locations, please refer to our web site.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC
reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters
office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents.
Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
852 6/03 Revision 1999, 2000, 2001, 2003 ADC Telecommunications, Inc. All Rights Reserved