Вы находитесь на странице: 1из 38

www.siemens.

com / protection

Selection Guide
for SIPROTEC and Reyrolle
Edition 3

Answers for infrastructure and cities.

Overview of Siemens Protection Catalogs

Selection
Guide for
SIPROTEC and
Reyrolle
6,3527(&
&RPSDFW 6,3527(&
'9'
',*6,
6,3527(&
7XWRULDO
7XWRULDO

SIPROTEC
Compact
Catalog

SIPROTEC 5
Catalog
Protection,
Automation and
Monitoring

5H\UROOH
'9'

SIPROTEC 4
Catalog
- SIPROTEC easy
- SIPROTEC
series 600
- Communication
- Accessories

Reyrolle
Catalog 1) 2)

 $YDLODEOHRQO\LQHQJOLVK
 ,QSUHSDUDWLRQ

Overview of Siemens protection catalogs

Protection selection guide:


The selection guide offers an overview of the device series of
the Siemens protection devices, and a device selection table.
SIPROTEC Compact catalog:
The SIPROTEC Compact catalog describes the features of the
SIPROTEC Compact series and presents the available devices
and their application possibilities.
SIPROTEC 5 catalog:
The catalog describes the system features and the devices of
SIPROTEC 5.

2 Selection Guide for SIPROTEC and Reyrolle Edition 3

SIPROTEC 4, SIPROTEC series 600, SIPROTEC easy,


communication and accessories:
This catalog describes the features of the device series
SIPROTEC 4, SIPROTEC series 600 and SIPROTEC easy, as
well as their devices. In further chapters, the accessories of
the complete SIPRROTEC family for communication,
auxiliary relays and test equipment are described.
Reyrolle catalog:
This catalog gives an overview of the reyrolle devices.

Contents
Selection Guide
for SIPROTEC
and Reyrolle
Edition 3

Protection Devices Series


SIPROTEC and Reyrolle Relay Families
SIPROTEC 5
SIPROTEC Compact
SIPROTEC 4
SIPROTEC easy and SIPROTEC Compact (series 600)
Reyrolle

4
5
6
7
8
9

Overview, Relay Selection Table


Part 1

Invalid: Selection Guide for SIPROTEC and Reyrolle Edition 2

10 to 17
Functions

Part 2

www.siemens.com/protection

19 to 26
Functions (continued)
Further Functions
Hardware Feature

Part 3

28 to 35
Hardware Feature (continued)
Communication

Legal Notice
36

The products and systems described in this catalog


are manufactured and sold according to a certied
management system (acc. to ISO 9001, ISO 14001
and BS OHSAS 18001).

Selection Guide for SIPROTEC and Reyrolle Edition 3 3

Protection Devices
SIPROTEC and Reyrolle Relay Families
Solutions for today's and future power supply systems
for more than 100 years
With the two brands SIPROTEC and REYROLLE, Siemens is the
world market leader in digital protection technology. Prot from
the experience out of an installed base of more than 1 million
devices and 300,000 with IEC 61850.
SIPROTEC has established itself on the energy market for
decades as a powerful and complete system family of numerical protection relays and bay controllers from Siemens.
SIPROTEC protection relays from Siemens can be consistently
used throughout all applications in medium and high voltage.
With SIPROTEC, operators have their systems rmly and safely
under control, and have the basis to implement cost-efcient
solutions for all duties in modern, intelligent and smart grids.
Users can combine the units of the different SIPROTEC device
series at will for solving manifold duties because SIPROTEC
stands for continuity, openness and future-proof design.
As the innovation driver and trendsetter in the eld of protection systems for 100 years, Siemens helps system operators to
design their grids in an intelligent, ecological, reliable and
efcient way, and to operate them economically. As a pioneer,
Siemens has decisively inuenced the development of numerical protection systems (g. 2). The rst application went into
operation in Wrzburg, Germany, in 1977. Consistent integration of protection and control functions for all SIPROTEC devices
was the innovation step in the 90ies. After release of the
communication standard IEC 61850 in the year 2004, Siemens
was the rst manufacturer worldwide to put a system with this
communication standard into operation.
How can system operators benet from this experience?
Proven and complete applications
Easy integration into your system
Highest quality of hardware and software
Excellent operator friendliness of devices and tools

Fig. 2: SIPROTEC Pioneer over generations


4 Selection Guide for SIPROTEC and Reyrolle Edition 3

Fig. 1: Siemens protection family

Easy data exchange between applications


Extraordinary consistency between product- and
systemengineering
Reduced complexity by easy operation
Siemens as a reliable, worldwide operating partner
Reyrolle
The products of the long-standing British manufacturer Reyrolle
are considered especially powerful and reliable by many
markets. With the latest numerical products, Reyrolle as a part
of Siemens shows that the development is being pushed
forward, and that new innovations are continuously being
developed further for the users' benet. In this way, Reyrolle
completes the offerings for protection devices, particularly in
Great Britain and the Commonwealth countries.

Protection Devices
SIPROTEC 5
SIPROTEC 5 the new benchmark for protection, automation
and monitoring
The SIPROTEC 5 series is based on the long eld experience of
the SIPROTEC device series, and has been especially designed for
the new requirements of modern high-voltage systems. For this
purpose, SIPROTEC 5 is equipped with extensive functionalities
and device types. With the holistic and consistent engineering
tool DIGSI 5, a solution has also been provided for the
increasingly complex processes, from the design via the
engineering phase up to the test and operation phase.
Thanks to the high modularity of hardware and software, the
functionality and hardware of the devices can be tailored to the
requested application and adjusted to the continuously changing
requirements throughout the entire life cycle.
Besides the reliable and selective protection and the complete
automation function, SIPROTEC 5 offers an extensive database
for operation and monitoring of modern power supply systems.
Synchrophasors (PMU), power quality data and extensive
operational equipment data are part of the scope of supply.
Powerful protection functions guarantee the safety of the
system operator's equipment and employees
Individually congurable devices save money on initial
investment as well as storage of spare parts, maintenance,
expansion and adjustment of your equipment
Clear and easy-to-use of devices and software thanks to
user-friendly design
Increase of reliability and quality of the engineering process
High reliability due to consequent implementation of safety
and security
Powerful communication components guarantee safe and
effective solutions
Full compatibility between IEC 61850 Editions 1 and 2
Integrated switch for low-cost and redundant optical and
electrical Ethernet rings
Ethernet redundancy protocols RSTP, PRP and HSR
Efcient operating concepts by exible engineering of
IEC 61850 Edition 2
Comprehensive database for monitoring of modern power
grids
Optimal smart automation platform for transmission grids
based on integrated synchrophasor measurement units
(PMU) and power quality functions.

Fig. 3: SIPROTEC 5 modular hardware

Fig. 4: SIPROTEC 5 rear view

The SIPROTEC 5 devices have a basic housing width of


1/3 x 19, and are exibly expandable except for 7xx82
and 7xx84.

Fig. 5: Application in the high-voltage system

Selection Guide for SIPROTEC and Reyrolle Edition 3 5

Protection Devices
SIPROTEC Compact
SIPROTEC Compact
Maximum protection-minimum space
Reliable and exible protection for energy distribution and
industrial systems with minimum space requirements. The
devices of the SIPROTEC Compact family offer an extensive
variety of functions in a compact and thus space-saving 1/6 x 19"
housing. The devices can be used as main protection in mediumvoltage applications or as back-up protection in high-voltage
systems.
SIPROTEC Compact provides suitable devices for many
applications in energy distribution, such as the protection of
feeders, lines or motors. Moreover, it also performs tasks such as
system decoupling, load shedding, load restoration, as well as
voltage and frequency protection.
The SIPROTEC Compact series is based on millions of operational
experience with SIPROTEC 4 and a further-developed, compact
hardware, in which many customer suggestions were integrated.
This offers maximum reliability combined with excellent
functionality and exibility.
Simple installation by means of pluggable current and
voltage terminal blocks
Thresholds adjustable via software (3 stages guarantee a
safe and reliable recording of input signals)
Easy adjustment of secondary current transformer values
(1 A/5 A) to primary transformers via DIGSI 4
Quick operations at the device by means of 9 freely
programmable function keys
Clear overview with six-line display
Easy service due to buffer battery replaceable at the front
side
Use of standard cables via USB port at the front
Integration in the communication network by means of two
further communication interfaces
Integrated switch for low-cost and redundant optical
Ethernet rings
Ethernet redundancy protocols RSTP, PRP and HSR for highest
availability
Reduction of wiring between devices by means of crosscommunication via Ethernet (IEC 61850 GOOSE)
Time synchronization to the millisecond via Ethernet with
SNTP for targeted fault evaluation
Adjustable to the protection requirements by means of
exible protection functions
Comfortable engineering and evaluation via DIGSI 4.

Fig. 6: SIPROTEC Compact

Fig. 7: SIPROTEC Compact rear view

Fig. 8: Feeder Protection SIPROTEC 7SC80 with HMI

6 Selection Guide for SIPROTEC and Reyrolle Edition 3

Protection Devices
SIPROTEC 4
SIPROTEC 4 the proven, reliable and future-proof
protection for all applications
SIPROTEC 4 represents a worldwide successful and proven
device series with more than 1 million devices in eld use.
Due to the homogenous system platform, the unique engineering program DIGSI 4 and the great eld experience, the
SIPROTEC 4 device family has gained the highest appreciation
of users all over the world. Today, SIPROTEC 4 is considered
the standard for numerical protection systems in all elds of
application.
SIPROTEC 4 provides suitable devices for all applications from
power generation and transmission up to distribution and
industrial systems.
SIPROTEC 4 is a milestone in protection systems. The SIPROTEC 4
device series implements the integration of protection, control,
measuring and automation functions optimally in one device.
In many elds of application, all tasks of the secondary systems
can be performed with one single device. The open and
future-proof concept of SIPROTEC 4 has been ensured for the
entire device series with the implementation of IEC 61850.
Proven protection functions guarantee the safety of the
systems operator's equipment and employees
Comfortable engineering and evaluation via DIGSI 4
Simple creation of automation solutions by means of the
integrated CFC
Targeted and easy operation of devices and software thanks
to user-friendly design
Powerful communication components guarantee safe and
effective solutions
Maximum experience worldwide in the use of SIPROTEC 4
and in the implementation of IEC 61850 projects
Future-proof due to exchangeable communication interfaces
and integrated CFC
Integrated switch for low-cost and redundant optical and
electrical Ethernet rings
Ethernet redundancy protocols RSTP, PRP and HSR.

Fig. 9: SIPROTEC 4

Fig. 10: SIPROTEC 4 rear view

Fig. 11: SIPROTEC 4 in power plant application

Selection Guide for SIPROTEC and Reyrolle Edition 3 7

Protection Devices
SIPROTEC easy, SIPROTEC Compact (series 600)
SIPROTEC easy
SIPROTEC easy are CT power supplied numerical overcurrent
protection relays, which can be used as line and transformer
protection (back-up protection) in electrical power supply
systems with single-ended supply. They offer denite-time and
inverse-time overcurrent protection functions according to
IEC and ANSI. The comfortable operation via DIP switch is
self-explanatory and simple.
Two-stage overcurrent-time protection
Saving the auxiliary power supply by operation via
integrated current transformer supply
Cost-efcient due to the use of instrument transformers with
low ratings
Tripping via pulse output (DC 24 V / 0.1 Ws) or tripping relay
output
Simple, self-explanatory parameterization and operation via
DIP switch directly at the device
Easy installation due to compact assembly on DIN rail.
Fig. 12: SIPROTEC easy

SIPROTEC Compact (series 600)


The devices of this series are compact, numerical protection
devices for application in medium-voltage or industrial power
supply systems. The corresponding device types are available for
the different applications such as overcurrent-time protection,
line differential protection, transient earth-fault relay or busbar
protection.
Space-saving due to compact design
Reliable process connections by means of solid terminal
blocks
Effective fault evaluation by means of integrated fault
recording and SIGRA 4
Communication interface
Operable and evaluable via DIGSI 4
Different device types available for directional and nondirectional applications.

Fig. 13: SIPROTEC Compact (series 600)

8 Selection Guide for SIPROTEC and Reyrolle Edition 3

Protection Devices
Reyrolle
Reyrolle Withdrawable solutions for distribution grids
Reyrolle has been synonymous with electrical protection devices
in the sectors of sub-transmission, distribution and industrial
applications for decades. Historically, Reyrolle relays, initially
sold mainly in traditional markets, are now sold worldwide as
part of the Siemens protection network.
Since its foundation, Reyrolle has been an innovation driver in
product development based on a strong focus on market,
customer and technology. Worldwide established brand names
such as Solkor and Argus demonstrate this. But there is more:
A wide range of Reyrolle products has determined technological
rsts in the market.
The comprehensive range of Reyrolle products provides the total
protection requirements of distribution markets ranging from
overcurrent protection via transformer protection and voltage
control to a full spectrum of auxiliary and trip relays. The
portfolio includes many famous products such as Argus,
Duobias, Solkor, MicroTAPP, etc.

Fig. 14: Front view Argus 7SR210

To serve specic needs in industrial applications, a range of


proven products such as Argus overcurrent, Solkor line
differential and Rho motor protection devices is offered.
Through successive generations, Reyrolle numerical products
have been developed to increase value to system operators.
This increase in value is the result of consistent development:
Ease-of-use as a principle our withdrawable product
solutions allow exible, easy operation through high user
friendliness.
One size ts all the 4U housing height and the latest
generation of numerical products features 1A/5A CT Input,
and some models are provided with universal DC supplies.
Learn once, know all the new product generation provides
a similar look and feel as earlier products. If Reyrolle
numerical devices have been previously used, there is a high
consistency in both programming and interrogation.
With Reydisp Evolution, a comprehensive software support
toolkit for relay setting, fault interrogation and general
system information is provided. It is backward-compatible
with all previous Reyrolle numerical devices.

Fig. 15: Rear view Argus 7SR210

Selection Guide for SIPROTEC and Reyrolle Edition 3 9

Overview, Relay Selection Table


Functions

Part 1
Siemens Protection Portfolio for all areas of application

Denition of device types based on designation


The devices are easily identied with the aid of a ve-digit abbreviation code. The rst digit
(6 or 7) stands for the classication. The two letters describe the functionality and the last two
digits identify typical properties.
Overview of the main functions
Main functions

Distinguishing features

6 or 7

YY

Classication
XX
SIPROTEC devices
KE
MD
RW
SA
SC
SD
SJ
SK
SL
SS
UM
UT
VK
VU
Reyrolle devices
SG
SR
PG

XX

Main functions
Fault recorder
Bay Controller
Voltage and Frequency Protection
Distance Protection
Feeder Protection
Line Differential Protection
Overcurrent Protection
Motor protection
Line Differntial and Distance Protection
Busbar Protection
Generator Protection
Transformer Protection
Breaker Manangement
High Speed Busbar
Numerical Protection
New Numerical protection
Electromechanical protection

Selection Guide for SIPROTEC and Reyrolle Edition 3 10

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

SIPROTEC 5

SIPROTEC 5

SIPROTEC 5

SIPROTEC 4

Reyrolle

SIPROTEC 4

Reyrolle

SIPROTEC 5

SIPROTEC 4

SIPROTEC 5

Abbr.

7SA84

7SA86

7SA87

7SA522

7SA61

Protection functions for 3-pole tripping

3-pole

Protection functions for 1-pole tripping

1-pole

14

Locked rotor protection

I> + V<

21

Distance protection

Z<

24

Overexcitation protection

V/f

25

Synchrocheck, synchronizing function

Sync

27

Undervoltage protection

V<

27TN / 59TN

Stator ground fault 3rd harmonics

V0<,>(3.Harm.)

27Q

Undervoltage-controlled reactive power protection

Q>/V<

32

Directional power supervision

37

Undercurrent protection, underpower

38
40

Line differential protection


SIPROTEC 4

SIPROTEC 5

Distance protection

7SA63

7SA64

7SG163

7SG164

7SD84

7SD86

7SD87

V
V

P<>, Q<>

Temperature supervision

I<, P<
>

Underexcitation protection

1/XD

46

Unbalanced-load protection

I2>

46
47

Negative-sequence system overcurrent protection

I2>, I2/I1>

Phase-sequence-voltage supervision

LA, LB, LC

48

Starting-time supervision

I2start

49

Thermal overload protection

>, I2t

Device series

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration
ANSI

Function
Functions

49H

Hot spot calculation

h>, I2t

50 / 50N

Denite time-overcurrent protection

I>

50Ns

Sensitive ground-current protection

INs>

Intermittent ground-fault protection

Iie>

50L

Load-jam protection

I>L

50BF

Circuit-breaker failure protection

CBFP

51 / 51N

Inverse time-overcurrent protection

Ip, INp

51C

Cold load pickup

51V

Voltage dependent overcurrent protection

t=f(I)+V<

55

Power factor

cos

C 2)

C 2)

C 2)

C 2)

C 2)

C 2)

C 2)

C 2)

C 2)

C 2)

C 2)

C 2)

59

Overvoltage protection

V>

59C

Peak overvoltage protection, 3-phase, for capacitors

V> cap.

59N

Overvoltage protection, zero-sequence system

V0>

59R, 27R

Rate-of-voltage-change protection

dV/dt

60C

Current-unbalance protection for capacitor banks

Iunbal>

60FL

Measuring-voltage failure detection

64

Sensitive ground-fault protection (machine)

66

Restart inhibit

I 2t

67

Directional time-overcurrent protection, phase

I>,IP (V,I)

IN>, INP (V,I)

67N

Directional time-overcurrent protection for ground-faults

67Ns

Dir. sensitive ground-fault detection for systems with resonant INs>, (V,I)
or isolated neutral

67Ns

Transient ground-fault function, for transient and permanent


ground faults in resonant-grounded or isolated networks

W0p,tr>

67Ns

Directional intermittent ground fault protection

Iie dir>

68

Power-swing blocking

Z/t

74TC

Trip-circuit supervision

TCS

78

Out-of-step protection

Z/t

79

Automatic reclosing

AR

11 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table

7SD80

14

21
C

7SD610

7SD5

7SD60

7PG2111

7SG18

7SL86

Protection
functions
for 3-pole
C
C
C tripping

3-pole

tripping
Protection
functions
for 1-pole
V

1-pole

Locked
rotor protection

I> + V<

Distance
protection
C
C

Z<

Reyrolle

Abbr.

Reyrolle

7SD87

Reyrolle

7SD86

High impedance protection

SIPROTEC 5

SIPROTEC 5

Reyrolle

Reyrolle

SIPROTEC
600er

SIPROTEC
Compact

SIPROTEC 4

SIPROTEC 5

7SD84

7SG163
Function 7SG164

Device series

SIPROTEC 4

SIPROTEC 5

7SA64

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Combined line differential


and distance protection

Line differential protection

SIPROTEC 5

7SA63
ANSI

Line differential protection


Reyrolle

SIPROTEC 4

SA61

Reyrolle

SIPROTEC 4

C = basic
V = optional (additional price)
= not available

SIPROTEC 4

protection

7SL87

7SR23

7PG23

7SG12

Functions

24

Overexcitation

protection

V/f

25
V

Synchrocheck,
V
VsynchronizingVfunction

Sync

27
V

Undervoltage
protection
V
V

V<

27TN
/ 59TN

Stator
ground fault
3rd harmonics

V0<,>(3.Harm.)

27Q
V

Undervoltage-controlled
reactive
power protection
V
V
V
V

Q>/V<

32
C

Directional
power

supervision
V

P<>, Q<>

37
V

Undercurrent
protection,
underpower
V
V
V

38
V

Temperature
supervision
V
V

I<, P<
>

40

Underexcitation

protection

1/XD

46

Unbalanced-load

protection V

I2>

46

Negative-sequence

system overcurrent
protection
V
V

I2>, I2/I1>

47
C

Phase-sequence-voltage
supervision
C
C
C

LA, LB, LC

48

Starting-time
supervision

I2start

49
C

Thermal

overload
V protectionV

>, I2t

h>, I2t

I>

49H

Hot
spot calculation

50
C / 50N

De
protection
C nite time-overcurrent
C
C

50Ns
V

Sensitive
ground-current
protection

V
V

INs>

Intermittent
ground-fault
protection
V
V
V

Iie>

50L

Load-jam
protection

I>L

50BF
V

Circuit-breaker
failure protection
V
V

CBFP

51
C / 51N

Inverse
time-overcurrent
protection

Ip, INp

51C

load pickup

Cold

51V
V

Voltage
dependent
overcurrent
V
V
V protectionV

t=f(I)+V<

cos

C 2)

C 2)

C 2)

C 2)

C 2)

2)
C55

C 2)

2)
Power
factor C 2)
C

59
V

Overvoltage
protection
V
V

59C

59N
V

59R,
27R

60C

C
C 2)

C 2)

C 2)

V>

Peak
capacitors
overvoltage
protection,3-phase, for

V> cap.

Overvoltage
protection,
zero-sequence
system

V
V

V0>

Rate-of-voltage-change
protection

dV/dt

Current-unbalance
protection

for capacitor banks

Iunbal>

60FL
C

Measuring-voltage
failure detection
C
C
C

64

Sensitive
ground-fault
protection
(machine)

66

Restart
inhibit

I 2t

67
C

Directional
time-overcurrent

Vprotection, phase
V

I>,IP (V,I)

67N
V

Directional
time-overcurrent

Vprotection forV ground-faults


V

IN>, INP (V,I)

67Ns
V

Dir.
detection
for systems
with resonant
INs>, (V,I)
sensitive ground-fault

V
V
V
or isolated neutral

67Ns
_

Transient
ground-fault
function,

V for transient
V and permanent
V
ground faults in resonant-grounded or isolated networks

W0p,tr>

67Ns

Directional
intermittent
ground

fault protection

Iie dir>

68
V

Power-swing
blocking
C
C

Z/t

74TC
C

Trip-circuit
supervision
C
C

TCS

78
V

Out-of-step
protection

Z/t

79
V

Automatic
reclosing
V
V

AR

12 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

SIPROTEC 5

SIPROTEC 5

SIPROTEC 5

SIPROTEC
Compact

SIPROTEC
Compact

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

SIPROTEC
easy

SIPROTEC
easy

SIPROTEC
600er

Overcurrent and feeder protection

Abbr.

7SJ82

7SJ85

7SJ86

7SJ80

7SJ81

7SJ61

7SJ62

7SJ63

7SJ64

7SJ66

7SJ45

7SJ46

7SJ600

Protection functions for 3-pole tripping

3-pole

Protection functions for 1-pole tripping

1-pole

14

Locked rotor protection

I> + V<

21

Distance protection

Z<

24

Overexcitation protection

V/f

25

Synchrocheck, synchronizing function

Sync

27

Undervoltage protection

V<

27TN / 59TN

Stator ground fault 3rd harmonics

V0<,>(3.Harm.)

27Q

Undervoltage-controlled reactive power protection

Q>/V<

32

Directional power supervision

P<>, Q<>

37

Undercurrent protection, underpower

C 2)

38

Temperature supervision

I<, P<
>

40

Underexcitation protection

1/XD

46

Unbalanced-load protection

I2>

46

Negative-sequence system overcurrent protection

I2>, I2/I1>

47

Phase-sequence-voltage supervision

LA, LB, LC

48

Starting-time supervision

I2start

49

Thermal overload protection

>, I2t

Device series

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration
ANSI

Function
Functions

49H

Hot spot calculation

h>, I2t

50 / 50N

Denite time-overcurrent protection

I>

50Ns

Sensitive ground-current protection

INs>

Intermittent ground-fault protection

Iie>

50L

Load-jam protection

I>L

50BF

Circuit-breaker failure protection

CBFP

51 / 51N

Inverse time-overcurrent protection

Ip, INp

51C

Cold load pickup

51V

Voltage dependent overcurrent protection

t=f(I)+V<

55

Power factor

cos

C 2)

C 2)

C 2)

C 2)

59

Overvoltage protection

V>

59C

Peak overvoltage protection, 3-phase, for capacitors

V> cap.

59N

Overvoltage protection, zero-sequence system

V0>

59R, 27R

Rate-of-voltage-change protection

dV/dt

60C

Current-unbalance protection for capacitor banks

Iunbal>

60FL

Measuring-voltage failure detection

64

Sensitive ground-fault protection (machine)

66

Restart inhibit

I 2t

67

Directional time-overcurrent protection, phase

I>,IP (V,I)

67N

Directional time-overcurrent protection for ground-faults

IN>, INP (V,I)

67Ns

Dir. sensitive ground-fault detection for systems with resonant INs>, (V,I)
or isolated neutral

67Ns

Transient ground-fault function, for transient and permanent


ground faults in resonant-grounded or isolated networks

W0p,tr>

67Ns

Directional intermittent ground fault protection

Iie dir>

68

Power-swing blocking

Z/t

74TC

Trip-circuit supervision

TCS

78

Out-of-step protection

Z/t

79

Automatic reclosing

AR

13 Selection Guide for SIPROTEC and Reyrolle Edition 3

7SR210

7SR220

SIPROTEC
Compact

7SR191

SIPROTEC
Compact

7SR12

SIPROTEC 5

7SR11

SIPROTEC 5

7SJ602

Reyrolle

Abbr.

Device series

Generator and motor protection

SIPROTEC
Compact

7SJ600

Reyrolle

7SJ46

Reyrolle

7SJ45

Reyrolle

SIPROTEC
600er

7SJ63 Function
7SJ64

Reyrolle

SIPROTEC
easy

7SJ61 ANSI 7SJ62

Reyrolle

SIPROTEC
easy

7SJ66

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Feeder Automation

SIPROTEC
600er

SIPROTEC 4

Overcurrent and feeder protection


SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

C and
= basic
Overcurrent
feeder protection
V = optional (additional price)
= not available
SIPROTEC 4

Compact

Overview, Relay Selection Table

7SC80

7SR224

7SK82

7SK85

7SK80

7SK81
C

Functions
C

Protection
C functions
C for 3-pole tripping
C

3-pole

functions
for 1-pole tripping

Protection

1-pole

1)

LockedVrotor protection
V

I> + V<

14

21

protection
Distance

Z<

24

Overexcitation
protection

V/f

25

Synchrocheck,
synchronizing
function

V
V

Sync

V 1)

27

Undervoltage
protection
V
V

V<

27TN / 59TN

Stator
ground fault3rd harmonics

V0<,>(3.Harm.)

27Q

Undervoltage-controlled
reactive
power protection

C
C

Q>/V<

32

37

C 2)

38

40

46

Directional
power supervision

V
V

P<>, Q<>

Undercurrent
protection,
underpower

C
C

Temperature
supervision
V
V

I<, P<
>

Underexcitation
protection

1/XD

Unbalanced-load
protection
C
C

I2>

46

Negative-sequence
protection

C
Csystem overcurrent

I2>, I2/I1>

47

Phase-sequence-voltage
supervision

C
C

LA, LB, LC

48

Starting-time
supervision
V
V

I2start

49

Thermal
C overload protection
C

>, I2t

49H

Hot spot
calculation

h>, I2t

50 / 50N C

Denite
protection
C time-overcurrent
C
C

I>

50Ns

Sensitive
protection

V ground-current
V

INs>

Intermittent
ground-fault
protection

V
V

Iie>

V 1)

V 1)

I>L

50L

Load-jam
V protection
V

50BF

Circuit-breaker
failure

C
C protection

CBFP

51 / 51N C

InverseCtime-overcurrent
protection
C
C

Ip, INp

51C

Cold load
C pickup

51V

VoltageC dependentCovercurrentprotection

t=f(I)+V<

55

C 2)

Power Vfactor

cos

C 2)

C 2)

59

Overvoltage
protection
V
V

V>

59C

Peak overvoltage
protection,
3-phase,
for capacitors

V> cap.

59N

Overvoltage
protection,
zero-sequence
system

V
V

V0>

59R, 27RV

Rate-of-voltage-change
protection

V
V

dV/dt

60C

Current-unbalance

protection for
capacitor banks

Iunbal>

60FL

Measuring-voltage

C
Cfailure detection

C
V

64

Sensitive
ground-fault
protection
(machine)

66

RestartVinhibit

I 2t

I>,IP (V,I)

IN>, INP (V,I)

67

Directional
time-overcurrent
protection,
phase

V
V

67N

Directional
time-overcurrent
protection
for ground-faults

V
V

67Ns

Dir. sensitive
ground-fault
detection
for systems
with resonant
INs>, (V,I)

V
V
or isolated neutral

67Ns

Transient
ground-fault
function, for transient
and permanent

ground faults in resonant-grounded or isolated networks

W0p,tr>

67Ns

Directional
intermittent
groundfault protection

C
C

Iie dir>

68

Power-swing
blocking

Z/t

74TC

Trip-circuit
supervision
C
C

TCS

78

Out-of-step
protection

Z/t

79

Automatic
V reclosing
V

AR

14 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

SIPROTEC 4

Reyrolle

Reyrolle

SIPROTEC 5

SIPROTEC 5

SIPROTEC 5

SIPROTEC 5

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

Transformer protection

SIPROTEC 4

Generator and motor protection

Abbr.

7UM61

7UM62

7SR17

7SG17

7UT82 1)

7UT85

7UT86

7UT87

7UT612

7UT613

7UT63

Protection functions for 3-pole tripping

3-pole

Protection functions for 1-pole tripping

1-pole

Locked rotor protection

I> + V<

21

Distance protection

Z<

24

Overexcitation protection

V/f

25

Synchrocheck, synchronizing function

Sync

27

Undervoltage protection

V<

27TN / 59TN

Stator ground fault 3rd harmonics

V0<,>(3.Harm.)

27Q

Undervoltage-controlled reactive power protection

Q>/V<

32

Directional power supervision

P<>, Q<>

37

Undercurrent protection, underpower

38

Temperature supervision

I<, P<
>

40

Underexcitation protection

1/XD

46

Unbalanced-load protection

I2>

Device series

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration
ANSI

Function
Functions

14

46

Negative-sequence system overcurrent protection

I2>, I2/I1>

47

Phase-sequence-voltage supervision

LA, LB, LC

48

Starting-time supervision

I2start

49

Thermal overload protection

>, I2t

49H

Hot spot calculation

h>, I2t

50 / 50N

Denite time-overcurrent protection

I>

50Ns

Sensitive ground-current protection

INs>

Intermittent ground-fault protection

Iie>

50L

Load-jam protection

I>L

50BF

Circuit-breaker failure protection

CBFP

51 / 51N

Inverse time-overcurrent protection

Ip, INp

51C

Cold load pickup

51V

Voltage dependent overcurrent protection

t=f(I)+V<

55

Power factor

cos

59

Overvoltage protection

V>

59C

Peak overvoltage protection, 3-phase, for capacitors

V> cap.

59N

Overvoltage protection, zero-sequence system

V0>

59R, 27R

Rate-of-voltage-change protection

dV/dt

60C

Current-unbalance protection for capacitor banks

Iunbal>

60FL

Measuring-voltage failure detection

64

Sensitive ground-fault protection (machine)

66

Restart inhibit

I 2t

67

Directional time-overcurrent protection, phase

I>,IP (V,I)

IN>, INP (V,I)

67N

Directional time-overcurrent protection for ground-faults

67Ns

Dir. sensitive ground-fault detection for systems with resonant INs>, (V,I)
or isolated neutral

67Ns

Transient ground-fault function, for transient and permanent


ground faults in resonant-grounded or isolated networks

W0p,tr>

67Ns

Directional intermittent ground fault protection

Iie dir>

68

Power-swing blocking

Z/t

74TC

Trip-circuit supervision

TCS

78

Out-of-step protection

Z/t

79

Automatic reclosing

AR

15 Selection Guide for SIPROTEC and Reyrolle Edition 3

SIPROTEC 4

7SS85

SIPROTEC 4

7SR24

SIPROTEC 4

7SG14

SIPROTEC 5

Abbr.

SIPROTEC 5

7UT63

SIPROTEC
600er

7UT613

Bay controller

SIPROTEC 4

7UT86Function7UT87

SIPROTEC 5

7UT82 1) ANSI 7UT85

Device series

Busbar protection

Reyrolle

SIPROTEC 4

7UT612

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Reyrolle

SIPROTEC 4

Transformer protection
SIPROTEC 4

SIPROTEC 5

SIPROTEC 5

C = basic
Transformer protection
V = optional (additional price)
= not available
SIPROTEC 5

SIPROTEC 5

Overview, Relay Selection Table

7SS52

7SS60

6MD85

6MD86

6MD61

6MD63

6MD66

Functions
C

Protection functions
for 3-pole
tripping C
C
C

3-pole

Protection functions
for 1-pole
tripping

1-pole

14

protection
Locked rotor

I> + V<

21

Distance protection
V

Z<

24

Overexcitation
V protection

V/f

25

Synchrocheck,
function
V synchronizing

Sync

27

Undervoltage
V protection

V<

27TN / 59TN

Stator ground
fault 3rd harmonics

V0<,>(3.Harm.)

27Q

Undervoltage-controlled
reactive

power protection
V

Q>/V<

32

Directional Vpower supervision

P<>, Q<>

37

Undercurrent
protection, underpower

38

Temperature
V supervision V

I<, P<
>

40

Underexcitation
protection

1/XD

46

Unbalanced-load
protection
V
V

I2>

46

Negative-sequence
systemV overcurrent protection
V
V

I2>, I2/I1>

47

Phase-sequence-voltage
supervision
C
C

LA, LB, LC

48

Starting-time
supervision

I2start

49

Thermal overload
protection
C
C

>, I2t

49H

Hot spot calculation


V

h>, I2t

50 / 50N C

Denite time-overcurrent
C
Cprotection

I>

50Ns

Sensitive ground-current
protection

INs>

Intermittent
ground-fault protection

Iie>

50L

Load-jam protection

I>L

50BF

Circuit-breaker
V failure protection
V

CBFP

51 / 51N C

Inverse time-overcurrent
protection
C
C

Ip, INp

51C

Cold load pickup

51V

Voltage dependent

overcurrent

protection

t=f(I)+V<

55

Power factor
V

cos

59

Overvoltage
V protection

V>

59C

Peak overvoltage
protection,

3-phase, for capacitors

V> cap.

59N

Overvoltage
system

V protection, zero-sequence
V

V0>

59R, 27R

Rate-of-voltage-change
protection

dV/dt

60C

Current-unbalance
protection

for capacitor
banks

Iunbal>

60FL

Measuring-voltage
failuredetection
V

64

Sensitive ground-fault
protection
(machine)

66

Restart inhibit

I 2t

67

Directional Vtime-overcurrent
protection, phase

I>,IP (V,I)

67N

Directional Vtime-overcurrent
protection for
ground-faults

IN>, INP (V,I)

67Ns

Dir. sensitive
with resonant
INs>, (V,I)

V ground-faultdetection for systems


or isolated neutral

67Ns

Transient ground-fault
function,
for transient
and permanent

ground faults in resonant-grounded or isolated networks

W0p,tr>

67Ns

Directional Vintermittent ground


fault protection

Iie dir>

68

Power-swing
blocking

Z/t

74TC

Trip-circuit Csupervision

TCS

78

Out-of-stepprotection

Z/t

79

Automatic reclosing

AR

16 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table


Reyrolle

Reyrolle

SIPROTEC 5

7VE6

Reyrolle

7VK61

Fault Recorder

SIPROTEC
600er

7VK87

Voltage and frequency protection


SIPROTEC
Compact

Abbr.

High speed
Busbar transfer
SIPROTEC 4

Function

SIPROTEC 4

ANSI

SIPROTEC 4

Device series

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Synchronizing

SIPROTEC 5

Breaker management

Reyrolle

C = basic
V = optional (additional price)
= not available

7SG117

7VU683

7RW80

7RW60

7SR158

7SG118

7SG15

7KE85

Functions
Protection functions for 3-pole tripping

3-pole

Protection functions for 1-pole tripping

1-pole

14

Locked rotor protection

I> + V<

21

Distance protection

Z<

24

Overexcitation protection

V/f

25

Synchrocheck, synchronizing function

Sync

27

Undervoltage protection

V<

27TN / 59TN

Stator ground fault 3rd harmonics

V0<,>(3.Harm.)

27Q

Undervoltage-controlled reactive power protection

Q>/V<

32

Directional power supervision

P<>, Q<>

37

Undercurrent protection, underpower

Temperature supervision

I<, P<
>

38

40

Underexcitation protection

1/XD

46

Unbalanced-load protection

I2>

46

Negative-sequence system overcurrent protection

I2>, I2/I1>

47

Phase-sequence-voltage supervision

LA, LB, LC

48

Starting-time supervision

I2start

49

Thermal overload protection

>, I2t

49H

Hot spot calculation

h>, I2t

50 / 50N

Denite time-overcurrent protection

I>

50Ns

Sensitive ground-current protection

INs>

Intermittent ground-fault protection

Iie>

50L

Load-jam protection

I>L

50BF

Circuit-breaker failure protection

CBFP

51 / 51N

Inverse time-overcurrent protection

Ip, INp

51C

Cold load pickup

51V

Voltage dependent overcurrent protection

t=f(I)+V<

55

Power factor

cos

59

Overvoltage protection

59C

Peak overvoltage protection, 3-phase, for capacitors

59N

Overvoltage protection, zero-sequence system

59R, 27R

Rate-of-voltage-change protection

Iunbal>

C 2)

V>

V> cap.

V0>

dV/dt

60C

Current-unbalance protection for capacitor banks

60FL

Measuring-voltage failure detection

64

Sensitive ground-fault protection (machine)

66

Restart inhibit

I 2t

67

Directional time-overcurrent protection, phase

67N

Directional time-overcurrent protection for ground-faults

67Ns

Dir. sensitive ground-fault detection for systems with resonant INs>, (V,I)
or isolated neutral

67Ns

Transient ground-fault function, for transient and permanent


ground faults in resonant-grounded or isolated networks

67Ns
68
74TC
78
79

I>,IP (V,I)

IN>, INP (V,I)

W0p,tr>

C 1)

Directional intermittent ground fault protection

Iie dir>

Power-swing blocking

Z/t

Trip-circuit supervision

TCS

Out-of-step protection

Z/t

Automatic reclosing

AR

17 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table

Relay Selection Table


to be continued
on the following pages

Selection Guide for SIPROTEC and Reyrolle Edition 3 18

Overview, Relay Selection Table


Functions (continued)
Further fuctions
Hardware Feature
Part 2
Siemens Protection Portfolio for all areas of application

Denition of device types based on designation


The devices are easily identied with the aid of a ve-digit abbreviation code. The rst digit
(6 or 7) stands for the classication. The two letters describe the functionality and the last two
digits identify typical properties.
Overview of the main functions
Main functions

Distinguishing features

6 or 7

YY

Classication
XX
SIPROTEC devices
KE
MD
RW
SA
SC
SD
SJ
SK
SL
SS
UM
UT
VK
VU
Reyrolle devices
SG
SR
PG

XX

Main functions
Fault recorder
Bay Controller
Voltage and Frequency Protection
Distance Protection
Feeder Protection
Line Differential Protection
Overcurrent Protection
Motor protection
Line Differntial and Distance Protection
Busbar Protection
Generator Protection
Transformer Protection
Breaker Manangement
High Speed Busbar
Numerical Protection
New Numerical protection
Electromechanical protection

Selection Guide for SIPROTEC and Reyrolle Edition 3 19

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

Reyrolle

Reyrolle

SIPROTEC 5

SIPROTEC 5

SIPROTEC 5

Abbr.

SIPROTEC 4

Function

SIPROTEC 5

ANSI

SIPROTEC 5

Device series

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Line differential protection

SIPROTEC 5

Distance protection

7SA84

7SA86

7SA87

7SA522

7SA61

7SA63

7SA64

7SG163

7SG164

7SD84

7SD86

7SD87

Functions
81

Frequency protection

f<, f>

81R

Rate-of-frequency-change protection

df/dt

Vector-jump protection

U>

81LR

Load restoration

LR

85

Teleprotection

86

Lockout

87

Differential protection

87N

Differential ground-fault protection

IN

V
C

Broken-wire detection for differential protection

90V

Automatic voltage control

FL

Fault locator

FL

PMU

Synchrophasor measurement

PMU

Measured values

Switching-statistic counters

Logic editor

Inrush-current detection

External trip initiation

Control

High Speed busbar transfer function

Fault recording of analog and binary signals

Further Functions

Circuit breaker wear monitoring

Ix, I2t, 2P

Fast-scan recorder

FSR

Slow-scan recorder

SSR

Continuous recorder

CR

Power quality recorder (class S)

PQR

Extended fault recording

GOOSE recorder
Sequence-of-events recorder

SOER

Extended trigger functions

ExTrFct

Monitoring and supervision

Protection interface, serial

No. Setting groups

Changeover of setting group

Circuit breaker test

Hardware Feature

Binary Inputs (max)

5 3)

31 3)

31 3)

24

33

33

33

27

27

5 3)

31 3)

31 3)

Binary Outputs (max) incl. Life contact

8 3)

46 3)

46 3)

44

34

34

34

29

29

8 3)

46 3)

46 3)

Hardware quantity structure expandable

I/O

Internal RTD Inputs (max)

Transducer inputs (0-20mA) (max)

12

12

12

12

Analog measured value outputs (0-20mA) (max)

Current Inputs (max)

4 3)

8 3)

8 3)

4 3)

8 3)

8 3)

Voltage Inputs (max)

4 3)

8 3)

8 3)

4 3)

8 3)

8 3)

Low Power CT Inputs

Low Power VT Inputs

20 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table


SIPROTEC 5

SIPROTEC
Compact

SIPROTEC 4

SIPROTEC 4

SIPROTEC
600er

Reyrolle

Reyrolle

SIPROTEC 5

SIPROTEC 5

Reyrolle

Reyrolle

Reyrolle

81
V

Frequency
protection

81R

Rate-of-frequency-change
protection
V

Vector-jump
protection

81LR

85
C

High impedance protection

SIPROTEC 5

7SA64

Combined line differential


and distance protection

Line differential protection

SIPROTEC 5

7SA63
ANSI

7SD84

7SD86

7SD87

Abbr.

7SD80

7SD610

7SD5

7SD60

7PG2111

7SG18

7SL86

7SL87

7SR23

7PG23

7SG12

f<, f>

df/dt

U>

restoration

Load

LR

Teleprotection
V
V

86
C

Lockout
C

87

Differential
protection

87N
V

Differential
ground-fault
protection
V
V
V

IN

Broken-wire
detection
for differential
protection

C
C

90V

Automatic

voltage
control

FL
C

Fault
C locator C

FL

PMU

Synchrophasor

measurement
V

PMU

Reyrolle

SA61

Reyrolle

SIPROTEC 4

Line differential protection

SIPROTEC 4

C = basic
V = optional (additional price)
= not available

SIPROTEC 4

protection

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration
7SG163
Function 7SG164

Device series

Functions

Further Functions
C

Measured
values
C
C

Switching-statistic
C
C counters C

Circuit
breaker wear monitoring

Logic
editor

Inrush-current

detection

External
trip initiation
C
C

Control
C

High
transfer function
Speed busbar

Fault
C recordingCof analog and
C binary signals
C

Extended
faultrecording

Fast-scan recorder

FSR

Slow-scan recorder

SSR

Continuous recorder

CR

Power quality
recorder (class
S)

PQR

GOOSE recorder

recorder
Sequence-of-events

SOER

functions
Extended trigger

ExTrFct

Monitoring
andC supervision C
C

Protection
interface,
serial C
C
C

No.
8 Setting groups
8

Changeover
ofCsetting groupC
C

Circuit
breaker test

Ix, I2t, 2P

Hardware Feature

Hardware
quantity
structureexpandable C
C
C

33

33

33

Binary
Inputs (max)
27
27

31 3)

31 3)

3/7

24

31 3)

31 3)

19

27

34

34

34

Binary
Outputs29(max) incl. Life
29
8 3) contact 46 3)

46 3)

6/9

33

46 3)

46 3)

16

29

Internal
RTD Inputs
(max)

Transducer
inputs

(0-20mA) 4(max)

12

12

12

12

Analog
measured
(0-20mA) (max)

value outputs

Current
Inputs 4(max)
4

4 3)

8 3)

8 3)

8 3)

8 3)

Voltage
Inputs 4(max)
4

4 3)

8 3)

8 3)

8 3)

8 3)

Low
Inputs
Power CT

Low
Inputs
Power VT

21 Selection Guide for SIPROTEC and Reyrolle Edition 3

5 3)

I/O

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

SIPROTEC 5

SIPROTEC 5

SIPROTEC 5

SIPROTEC
Compact

SIPROTEC
Compact

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

SIPROTEC
easy

SIPROTEC
easy

SIPROTEC
600er

Overcurrent and feeder protection

Abbr.

7SJ82

7SJ85

7SJ86

7SJ80

7SJ81

7SJ61

7SJ62

7SJ63

7SJ64

7SJ66

7SJ45

7SJ46

7SJ600

Device series

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration
ANSI

Function
Functions

81

Frequency protection

f<, f>

81R

Rate-of-frequency-change protection

df/dt

Vector-jump protection

U>

81LR

Load restoration

LR

85

Teleprotection

86

Lockout

87

Differential protection

87N

Differential ground-fault protection

IN

Broken-wire detection for differential protection


90V

Automatic voltage control

FL

Fault locator

FL

PMU

Synchrophasor measurement

PMU

Measured values

Switching-statistic counters

Logic editor

Inrush-current detection

External trip initiation

C 2)

Control

High Speed busbar transfer function

Fault recording of analog and binary signals

Extended fault recording

Further Functions

Circuit breaker wear monitoring

Ix, I2t, 2P

Fast-scan recorder

FSR

Slow-scan recorder

SSR

Continuous recorder

CR

Power quality recorder (class S)

PQR

GOOSE recorder
Sequence-of-events recorder

SOER

Extended trigger functions

ExTrFct

Monitoring and supervision

Protection interface, serial

No. Setting groups

Changeover of setting group

Circuit breaker test

Hardware Feature
C

Binary Inputs (max)

11/23

59 3)

23 3)

3/7/11 1)

3/7

3/8/11

8/11

37

48

36

Binary Outputs (max) incl. Life contact

9/16

33 3)

24 3)

6/9/6 1)

6/9

5/9/7

9/7

19

26

24

Hardware quantity structure expandable

I/O

Internal RTD Inputs (max)

Transducer inputs (0-20mA) (max)

12

12

Analog measured value outputs (0-20mA) (max)

Current Inputs (max)

4 3)

4 3)

Voltage Inputs (max)

4 3)

4 3)

0/3

3/4

Low Power CT Inputs

Low Power VT Inputs

0/3

22 Selection Guide for SIPROTEC and Reyrolle Edition 3

SIPROTEC
Compact

7SR11

SIPROTEC
Compact

7SJ602

SIPROTEC 5

Abbr.

SIPROTEC 5

7SJ600

Reyrolle

Reyrolle

7SJ46

SIPROTEC
Compact

SIPROTEC
600er

7SJ45

Reyrolle

SIPROTEC
600er

7SJ63 Function
7SJ64

Reyrolle

SIPROTEC
easy

7SJ61 ANSI 7SJ62

Device series

Generator and motor protection

Reyrolle

SIPROTEC
easy

7SJ66

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Feeder Automation

Reyrolle

SIPROTEC 4

Overcurrent and feeder protection


SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

C and
= basic
Overcurrent
feeder protection
V = optional (additional price)
= not available
SIPROTEC 4

Compact

Overview, Relay Selection Table

7SR12

7SR191

7SR210

7SR220

7SC80

7SR224

7SK82

7SK85

7SK80

7SK81

Functions

81

Frequency
V protection
V

f<, f>

81R

Rate-of-frequency-change
protection
V
V

df/dt

Vector-jump
protection

U>

LR

81LR

Load restoration

85

Teleprotection

86

Lockout
C

IN

87

Differential
protection

87N

Differential
ground-fault
protection

V
V

Broken-wire
detection
protection

for differential

90V

Automatic
control
voltage

FL

Fault locator
V

FL

V 1)

V 1)

PMU

Synchrophasor
measurement

PMU

Further Functions
C

Measured
C values C

Switching-statistic
counters
C
C

Circuit breaker wear


monitoring

Logic editor
C

Inrush-current
detection
C
C

C 2)

External
C trip initiation
C

ControlC

High Speed
busbartransfer function

Fault recording
of analog
and binary
signals

C
C

Extended
fault recording

Fast-scan
recorder

FSR

Slow-scan
recorder

SSR

Continuous
recorder

CR

PQR

Power
(classS)
quality recorder

GOOSE
recorder

Sequence-of-events

recorder

Extended
triggerfunctions

Monitoring
and supervision
C
C

Ix, I2t, 2P

SOER

ExTrFct

Protection
interface,
serial

No. Setting
groups 4
4

Changeover
of setting
C
C group

Circuit breaker test

Hardware Feature

Hardware
quantity structure expandable

3/8/11

8/11

37

Binary48
Inputs (max)
36

19

13

12

43

11/23

27 3)

3/7

3/7

5/9/7

9/7

19

Binary26
Outputs (max)
24 incl. Life contact
1

16

14

30

9/16

17 3)

6/9

6/9

Internal
RTD Inputs(max)

Transducer
inputs (0-20mA)
(max)

12

Analogmeasured value
outputs (0-20mA) (max)

I/O

Current4 Inputs (max)


4

4/3

4 3)

3/4

Voltage4 Inputs (max)


4

0/1

1/4

4 3)

0/3

Low Power
CT Inputs

Low Power
VT Inputs

0/3

23 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

SIPROTEC 5

SIPROTEC 5

SIPROTEC 5

SIPROTEC 5

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

Abbr.

Reyrolle

Function

Reyrolle

ANSI

SIPROTEC 4

Device series

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Transformer protection

SIPROTEC 4

Generator and motor protection

7UM61

7UM62

7SR17

7SG17

7UT82 1)

7UT85

7UT86

7UT87

7UT612

7UT613

7UT63

Functions
81

Frequency protection

f<, f>

81R

Rate-of-frequency-change protection

df/dt

Vector-jump protection

U>

81LR

Load restoration

LR

85

Teleprotection

86

Lockout

87

Differential protection

87N

Differential ground-fault protection

IN

Broken-wire detection for differential protection

90V

Automatic voltage control

FL

Fault locator

FL

PMU

Synchrophasor measurement

PMU

Measured values

Switching-statistic counters

Inrush-current detection

External trip initiation

Control

High Speed busbar transfer function

Fault recording of analog and binary signals

Further Functions

Circuit breaker wear monitoring

Ix, I2t, 2P

Logic editor

Extended fault recording

Fast-scan recorder

FSR

Slow-scan recorder

SSR

Continuous recorder

CR

Power quality recorder (class S)

PQR

GOOSE recorder
Sequence-of-events recorder

SOER

Extended trigger functions

ExTrFct

Monitoring and supervision

Protection interface, serial

No. Setting groups

Changeover of setting group

Circuit breaker test

Hardware Feature

Binary Inputs (max)

15

15

4 3)

19 3)

23 3)

27 3)

29

Binary Outputs (max) incl. Life contact

20

21

5 3)

23 3)

34 3)

38 3)

25

Internal RTD Inputs (max)

Transducer inputs (0-20mA) (max)

12

12

12

Analog measured value outputs (0-20mA) (max)

Current Inputs (max)

8 3)

8 3)

12 3)

20 3)

11

14

Voltage Inputs (max)

0 3)

0 3)

4 3)

4 3)

0/4

Low Power CT Inputs

Low Power VT Inputs

Hardware quantity structure expandable

24 Selection Guide for SIPROTEC and Reyrolle Edition 3

I/O

7SS85

SIPROTEC 4

7SR24

SIPROTEC 4

7SG14

SIPROTEC 4

Abbr.

SIPROTEC 5

SIPROTEC 5

7UT63

SIPROTEC 5

Reyrolle

7UT613

SIPROTEC
600er

Reyrolle

7UT86Function7UT87

Device series

Bay controller

SIPROTEC 4

SIPROTEC 4

7UT612

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

7UT82 1) ANSI 7UT85

Busbar protection

SIPROTEC 4

Transformer protection
SIPROTEC 4

SIPROTEC 5

SIPROTEC 5

C = basic
Transformer protection
V = optional (additional price)
= not available
SIPROTEC 5

SIPROTEC 5

Overview, Relay Selection Table

7SS52

7SS60

6MD85

6MD86

6MD61

6MD63

6MD66

Functions

81

Frequency V
protection

f<, f>

81R

protection
Rate-of-frequency-change

df/dt

protection
Vector-jump

U>

LR

81LR

Load restoration

85

Teleprotection

86

Lockout

87

DifferentialCprotection

87N

DifferentialVground-fault protection
V

Broken-wire detection for Cdifferential protection


C

IN

90V

Automatic voltage
control
V

FL

Fault locator

FL

PMU

Synchrophasor

V measurement

PMU

Further Functions
C

Measured values
C

Switching-statistic
counters
C
C

Circuit breaker

C wear monitoring

Logic editorC

Inrush-current
C detection C

External trip
C initiation

Control

Ix, I2t, 2P

High Speedbusbar transfer


function

Fault recording
of analog C
and binary signals
C
C

Extended fault
recording

Fast-scan recorder

FSR

Slow-scan
recorder

SSR

Continuous
recorder

CR

Power quality
recorder (class S)

PQR

GOOSE recorder

Sequence-of-events
recorder

SOER

Extended
trigger functions

ExTrFct

MonitoringCand supervision
C

Protection interface,
serial
C

No. Setting8groups

ChangeoverC of setting group


C

Circuit breaker
C test

Hardware Feature

4 3)

19 3)

23 3) Binary Inputs
27 3)(max)

Hardware quantity
structure
expandable
C
5

29

27

19

15 3)

972

3 4)

59 3)

443 3)

80

37

65

5 3)

23 3)

34 3) Binary Outputs
38 3) (max) incl.5 Life contact 9

25

29

14

15 3)

370

2 4)

33 3)

80 3)

54

21

45

12

inputs (0-20mA)
12 Transducer12
(max)

12

12

12

8 3)

8 3)

12 3) Current Inputs
20 3) (max)

11

14

12

40; 60 1)

192

1 4)

4 3)

8 3)

0 3)

0 3)

4 3) Voltage Inputs
4 3) (max)

0/4

4 3)

8 3)

Low Power CT Inputs

Low Power VT Inputs

Internal RTD
Inputs (max)

Analog measured
value outputs
(0-20mA)

(max)

25 Selection Guide for SIPROTEC and Reyrolle Edition 3

I/O

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

Reyrolle

SIPROTEC 4

SIPROTEC
Compact

SIPROTEC
600er

Reyrolle

Reyrolle

Reyrolle

SIPROTEC 5

81R

Fault Recorder

SIPROTEC 4

81

Voltage and frequency protection

SIPROTEC 4

Function

High speed
Busbar transfer

7VK87

7VK61

7VE6

7SG117

7VU683

7RW80

7RW60

7SR158

7SG118

7SG15

7KE85

U>

LR

Device series

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased configuration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system configuration
ANSI

Synchronizing

SIPROTEC 5

Breaker management

Abbr.

Frequency protection

f<, f>

Rate-of-frequency-change protection

df/dt

Vector-jump protection
81LR

Load restoration

85

Teleprotection

86

Lockout

87

Differential protection

87N

Differential ground-fault protection

IN

Functions

Broken-wire detection for differential protection

90V

Automatic voltage control

FL

Fault locator

FL

PMU

Synchrophasor measurement

PMU

Measured values

Switching-statistic counters

Logic editor

Inrush-current detection

External trip initiation

Control

High Speed busbar transfer function

Fault recording of analog and binary signals

Extended fault recording

Further Functions

Circuit breaker wear monitoring

Ix, I2t, 2P

Fast-scan recorder

FSR

Slow-scan recorder

SSR

Continuous recorder

CR

Power quality recorder (class S)

PQR

V 1)

GOOSE recorder
Sequence-of-events recorder

SOER

Extended trigger functions

ExTrFct

Monitoring and supervision

Protection interface, serial

No. Setting groups

Changeover of setting group

Circuit breaker test

Hardware Feature
Hardware quantity structure expandable

I/O

Binary Inputs (max)

31 3)

20

6/14

17

3/7

19

19 3)

Binary Outputs (max) incl. Life contact

46 3)

19

10/18

19

6/9

11

13

15 3)

Internal RTD Inputs (max)

Transducer inputs (0-20mA) (max)

12

20

Analog measured value outputs (0-20mA) (max)

Current Inputs (max)

8 3)

12

Voltage Inputs (max)

8 3)

16

Low Power CT Inputs

Low Power VT Inputs

26 Selection Guide for SIPROTEC and Reyrolle Edition 3_V1.1

Overview, Relay Selection Table

Relay Selection Table


to be continued
on the following pages

Selection Guide for SIPROTEC and Reyrolle Edition 3 27

Overview, Relay Selection Table


Hardware Feature (continued)
Communication
Part 3
Siemens Protection Portfolio for all areas of application

Denition of device types based on designation


The devices are easily identied with the aid of a ve-digit abbreviation code. The rst digit
(6 or 7) stands for the classication. The two letters describe the functionality and the last two
digits identify typical properties.
Overview of the main functions
Main functions

Distinguishing features

6 or 7

YY

Classication
XX
SIPROTEC devices
KE
MD
RW
SA
SC
SD
SJ
SK
SL
SS
UM
UT
VK
VU
Reyrolle devices
SG
SR
PG

XX

Main functions
Fault recorder
Bay Controller
Voltage and Frequency Protection
Distance Protection
Feeder Protection
Line Differential Protection
Overcurrent Protection
Motor protection
Line Differntial and Distance Protection
Busbar Protection
Generator Protection
Transformer Protection
Breaker Manangement
High Speed Busbar
Numerical Protection
New Numerical protection
Electromechanical protection

Selection Guide for SIPROTEC and Reyrolle Edition 3 28

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

7SA61

7SA63

7SA64

SIPROTEC 5

7SA522

SIPROTEC 5

SIPROTEC 4

7SA87

SIPROTEC 5

SIPROTEC 4

7SA86

Reyrolle

SIPROTEC 4

7SA84

Reyrolle

SIPROTEC 4

Abbr.

SIPROTEC 5

Function

SIPROTEC 5

ANSI

Device series

Line differential protection

SIPROTEC 5

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Distance protection

7SG163

7SG164

7SD84

7SD86

7SD87
1/32/1

Hardware Feature
1/3

1/32/1

1/32/1

1/2; 1/1

1/31/1

1/2; 1/1

1/2; 1/1

1/3

1/32/1

Size (xE)

E12, E16

E12, E16

Small Display (lines)

8
320x240

Case (x19'')

320x240

320x240

320x240

240x120

240x120

320x240

320x240

Push Buttons

Key Switch

LEDs (max)

18

82

82

16

9/16

16

16

33

33

18

82

82

Pluggable terminal blocks

DC 30-48;
DV 88-250

DC 30-48;
DV 88-250

Large, graphical Display (Pixel)

PSU Variants

DC 2448; DC 24-48;
DC 24-48;
DC24-48;
DC24-48;
DC24-48;
DC24-48;
DC 60250/ DC 60-250/ DC 60-250/ DC60-125
DC60-125
DC60-125
DC60-125
AC 115230 AC 115-230 AC 115-230 DC110-250/ DC110-250/ DC110-250/ DC110-250/
AC115-230 AC115-230 AC115-230 AC115-230

DC 24-48;
DC 24-48;
DC 24-48;
DC 60-250/ DC 60-250/ DC 60-250/
AC 115-230 AC 115-230 AC 115-230

Communication
Front User Interface

IEC 60870-5-101

IEC 60870-5-103

IEC 60870-5-104

Probus FMS, Slave

Probus DP, Slave

Modbus RTU Slave

PROFINET I / O

DNP3 serial

DNP 3 TCP

IEC 61850

DIGSI

RTD-unit connection

20 mA unit connection

Synchro Phaser (IEEE C37.118)

Redundancy Protocols

RSTP (Ethernet ring redundancy)

PRP V1 (Parallel Redundancy Protocol)

HSR (High available Seamless Ring conguration)

Further Ethernet protocols on Ethernet modules

Time Synchronisation

V 1)

V 1)

V 1)

V 1)

V 1)

V 1)

IEEE 1588 C37.238 prole (PSRC - prole)

29 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table


Reyrolle

Reyrolle

7SD60

Reyrolle

7SD5

SIPROTEC 5

7SD610

SIPROTEC 5

7SD80

Reyrolle

Abbr.

High impedance protection

Reyrolle

7SD87

SIPROTEC
600er

7SD86

SIPROTEC 4

7SG163
Function 7SG164

Device series

SIPROTEC 4

1/2; 1/1

7SD84

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Combined line differential


and distance protection

Line differential protection


SIPROTEC
Compact

1/2; 1/1

SIPROTEC 5

31/1

SIPROTEC 5

7SA64

SIPROTEC 5

7SA63
ANSI

Reyrolle

SIPROTEC 4

SA61

Line differential protection

Reyrolle

SIPROTEC 4

C = basic
V = optional (additional price)
= not available

SIPROTEC 4

protection

7PG2111

7SG18

7SL86

7SL87

7SR23

7PG23

7SG12

Hardware Feature

240x120

240x120

(x19'')
Case

1/3

1/32/1

1/32/1

1/6

1/3

1/2; 1/1

1/6

1/32/1

1/32/1

E12, E16

E6

E8

E6, E8

E3

E8, E12

2
2
Small
Display (lines)

320x240

320x240

320x240

320x240

E12,
E16
Size
(xE)

Display (Pixel)
320x240
Large,
graphical

5 Buttons 5
Push

Switch
Key

9/16

16

16

33 (max)
LEDs

33

18

82

82

10

16

82

82

19

33

Pluggable
terminal
blocks

DC 24-48;
DC 60-250/
AC115-230

DC24-48;
DC60-125
DC110-250/
AC115-230

DC24-48;
DC60-125
DC110-250/
AC115-230

DC 30-48;
DV 88-250

DC 24-48;
DC 60-250/
AC 115-230

DC 24-48;
DC 60-250/
AC 115-230

DC 30-250

DC 30-48;
DV 88-250

24-48;
DC24-48;
DC24-48;
60-125
DC60-125
DC60-125
10-250/ DC110-250/ DC110-250/
15-230 AC115-230 AC115-230

DC PSU
30-48;
DC 30-48;
Variants
DV 88-250 DV 88-250

DC 24-48;
DC 24-48;
DC 24-48;
DC 60-250/ DC 60-250/ DC 60-250/
AC 115-230 AC 115-230 AC 115-230

Communication
C

Front
User Interface
C
C

60870-5-101

IEC

IEC
C 60870-5-103
C

60870-5-104

IEC

bus FMS, Slave

Pro

bus DP, Slave

Pro

Modbus
RTU Slave

PROFINET
I/O

DNP3
serial

DNP
3 TCP

IEC
61850

DIGSI

RTD-unit
connection

20
mA unit connection

Synchro
Phaser(IEEE C37.118)

Redundancy
Protocols

RSTP (Ethernet
ring redundancy)
V

PRP V1 (Parallel
Redundancy
V Protocol) V

Seamless
HSR (High available

V Ring conVguration)

Further
Ethernet

protocols on
C Ethernet modules
C

Time
C Synchronisation
C

IEEE
prole (PSRC
1588 C37.238

V 1) - prole)V 1)

V 1)

V 1)

V 1)

30 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

7SJ86

7SJ80

7SJ81

7SJ61

7SJ62

7SJ63

7SJ64

7SJ66

SIPROTEC
600er

SIPROTEC 4

7SJ85

SIPROTEC
easy

SIPROTEC
Compact

7SJ82

SIPROTEC
easy

SIPROTEC
Compact

Abbr.

SIPROTEC 5

Function

SIPROTEC 5

ANSI

Device series

SIPROTEC 5

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Overcurrent and feeder protection

7SJ45

7SJ46

7SJ600

Hardware Feature
1/3

1/32/1

1/32/1

1/6

1/6

1/3; 1/2

1/3; 1/3

1/2; 1/1

1/31/1

1/3; 1/2

1/6

Size (xE)

Small Display (lines)

320x240

320x240

320x240

240x120

240x120

240x120

240x120

240x128

Case (x19'')

Large, graphical Display (Pixel)


Push Buttons
Key Switch

LEDs (max)

16

82

82

10

10

16

16

16

Pluggable terminal blocks

PSU Variants

DC 24-48; DC 24-48; DC 24-48; DC 24-48; DC 24-48; DC 24-48; DC 24-48; DC 24-48; DC 24-48; DC 110-250/
DC 60-250/ DC 60-250/ DC 60-250/ DC 60-250/ DC 60-250/ DC 60-250/ DC 60-250/ DC 60-250/ DC 60-250/ AC 115-230
AC 115-230 AC 115-230 AC 115-230 AC115-230 AC115-230 AC115-230 AC115-230 AC115-230 AC115-230

DC 24-250/ DC24-48;
AC 60-230 DC60-125
DC110-250/
AC115-230

Communication
Front User Interface

IEC 60870-5-101

IEC 60870-5-103

IEC 60870-5-104

Probus FMS, Slave

Probus DP, Slave

Modbus RTU Slave

PROFINET I / O

DNP3 serial

DNP 3 TCP

IEC 61850

DIGSI

RTD-unit connection

20 mA unit connection

Synchro Phaser (IEEE C37.118)

Redundancy Protocols

RSTP (Ethernet ring redundancy)

PRP V1 (Parallel Redundancy Protocol)

HSR (High available Seamless Ring conguration)

Further Ethernet protocols on Ethernet modules


Time Synchronisation
IEEE 1588 C37.238 prole (PSRC - prole)

31 Selection Guide for SIPROTEC and Reyrolle Edition 3

V 1)

V 1)

V 1)

Reyrolle

SIPROTEC 5

SIPROTEC 5

SIPROTEC
Compact

SIPROTEC
Compact

Abbr.

SIPROTEC
Compact

7SJ600

Reyrolle

7SJ46

Reyrolle

7SJ45

Reyrolle

SIPROTEC
600er

7SJ63 Function
7SJ64

Reyrolle

SIPROTEC
easy

7SJ61 ANSI 7SJ62

Device series

Generator and motor protection

Reyrolle

SIPROTEC
easy

7SJ66

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Feeder Automation

SIPROTEC
600er

SIPROTEC 4

Overcurrent and feeder protection


SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

C and
= basic
Overcurrent
feeder protection
V = optional (additional price)
= not available
SIPROTEC 4

Compact

Overview, Relay Selection Table

7SJ602

7SR11

7SR12

7SR191

7SR210

7SR220

7SC80

7SR224

7SK82

7SK85

7SK80

7SK81

Hardware Feature
1/3; 1/2

1/3; 1/3

1/2; 1/1 Case


1/31/1
(x19'')

Size (xE)

1/3; 1/2

1/6

1/6

1/3

1/32/1

1/6

E4

E4

E4

E6, E8

E6, E8

E10, E12

240x120

240x120

8
Small Display
(lines)

240x120 Large,
240x120
graphical240x128
Display (Pixel)
4

4
Push Buttons

1/6

320x240

320x240

11

11

10

17

Key Switch
C

16

16
LEDs (max)

16

10

10

10

19

19

32

19

82

82

10

10

terminalblocks
Pluggable

48; DC 24-48; DC 24-48; DC 24-48; PSU


DCVariants
24-48; DC 110-250/
250/ DC 60-250/ DC 60-250/ DC 60-250/ DC 60-250/ AC 115-230
230 AC115-230 AC115-230 AC115-230 AC115-230

DC 24-250/ DC24-48;
AC 60-230 DC60-125
DC110-250/
AC115-230

DC24-48;
DC 24-60;
DC60-125 DV 88-250
DC110-250/
AC115-230

DC 24-60;
DV 88-250

DC 24-60;
DC 88250/115V

DC 30-250

DC 30-250

DC 24-48; DC 30-250 DC 24-48;


DC 24-48;
DC 24-48;
DC 24-48;
DC 60-250 /
DC 60-250/ DC 60-250/ DC 60-250/ DC 60-250/
AC115-232
AC 115-230 AC 115-230 AC115-230 AC115-230

Communication
C

Front User
C InterfaceC

IEC 60870-5-101

IEC 60870-5-103
V
V

IEC 60870-5-104

Probus
V FMS, Slave

Probus
V DP, Slave

V
V

Modbus
V RTU Slave V

PROFINET
V I/O

DNP3 serial
V

DNP 3 VTCP

IEC 61850
V

DIGSI V

RTD-unit
V connection
V

20 mAunit connection
V

Synchro
Phaser (IEEE
C37.118)

Redundancy
Protocols

RSTPV (Ethernet ring


redundancy)

PRP VV1 (Parallel Redundancy

Protocol)

HSRV(High available
Seamless Ring conguration)

FurtherV Ethernet protocols


on Ethernet
modules

Time Synchronisation
C
C

IEEE 1588
C37.238prole (PSRC
- prole)

V 1)

V 1)

32 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table


C = basic
V = optional (additional price)
= not available

SIPROTEC 5

SIPROTEC 5

SIPROTEC 5

SIPROTEC 4

SIPROTEC 4

SIPROTEC 4

7UM62

SIPROTEC 5

7UM61

Reyrolle

Abbr.

Transformer protection

Reyrolle

Function

SIPROTEC 4

ANSI

Device series

SIPROTEC 4

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Generator and motor protection

7SR17

7SG17

7UT82 1)

7UT85

7UT86

7UT87

7UT612

7UT613

7UT63

Hardware Feature
1/3; 1/2

1/2; 1/1

1/3

1/32/1

1/32/1

1/32/1

1/3

1/2

1/1

Size (xE)

E4

E6, E8

Small Display (lines)

Large, graphical Display (Pixel)

240x120

320x240

320x240

320x240

320x240

240x120

Push Buttons

Key Switch

LEDs (max)

9/16

10

16

82

82

82

16

16

Pluggable terminal blocks

DC 24-48;
DC 60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

DC 24-60;
DC 88250/115V

DC 24-60
DC 88-250

DC24-48;
DC60-250/
AC115-230

DC24-48;
DC60-250/
AC115-230

DC24-48;
DC60-250/
AC115-230

DC24-48;
DC60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

Front User Interface

IEC 60870-5-101

IEC 60870-5-103

Case (x19'')

PSU Variants

Communication

IEC 60870-5-104

Probus FMS, Slave

Probus DP, Slave

Modbus RTU Slave

PROFINET I / O

DNP3 serial

DNP 3 TCP

IEC 61850

DIGSI

RTD-unit connection

20 mA unit connection

Synchro Phaser (IEEE C37.118)

Redundancy Protocols

RSTP (Ethernet ring redundancy)

PRP V1 (Parallel Redundancy Protocol)

HSR (High available Seamless Ring conguration)

Further Ethernet protocols on Ethernet modules

Time Synchronisation

IEEE 1588 C37.238 prole (PSRC - prole)

V 1)

V 1)

V 1)

V 1)

33 Selection Guide for SIPROTEC and Reyrolle Edition 3

240x120

SIPROTEC 4

SIPROTEC 4

1/1

SIPROTEC 4

1/2

SIPROTEC 5

1/3

Abbr.

SIPROTEC 5

7UT63

SIPROTEC
600er

7UT613

SIPROTEC 4

7UT86Function7UT87

SIPROTEC 5

SIPROTEC 4

7UT82 1) ANSI 7UT85

Device series

Bay controller

Reyrolle

SIPROTEC 4

7UT612

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased conguration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system conguration

Busbar protection

Reyrolle

SIPROTEC 4

Transformer protection

SIPROTEC 5

SIPROTEC 5

C = basic
Transformer protection
V = optional (additional price)
= not available
SIPROTEC 5

SIPROTEC 5

Overview, Relay Selection Table

7SG14

7SR24

7SS85

7SS52

7SS60

6MD85

6MD86

6MD61

6MD63

6MD66

1/2-1/1; 2x1/1 1)

1/31/1

1/6 4)

1/32/1

1/32/1

1/2; 1/1

1/2; 1/1

1/1

E8, E12, E16

E8, E10

320x240

320x240

320x240

240x120

240x120

240x120

Hardware Feature
1/3

1/32/1

1/32/1Case (x19'')
1/32/1

Size (xE)

8 (lines)
Small Display

320x240

320x240

320x240
320x240 Display (Pixel)

Large, graphical

9
Push Buttons

196

Key Switch V

16

82

82 LEDs (max)82

16

16

33

27

82

898

82

82

16

16

16

Pluggable terminal
blocks
C

DC24-48;
DC60-250/
AC115-230

DC24-48;
DC60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

DC 24-60
DC 88/250

DC 30-250

DC24-48;
DC60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

DC24-48;
DC60-125
DC110-250/
AC115-230

DC24-48;
DC60-250/
AC115-230

DC24-48;
DC60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

DC 24-48;
DC 60-250/
AC115-230

Front User C
Interface

IEC 60870-5-101

IEC 60870-5-103
V

IEC 60870-5-104
V

Slave
Probus FMS,

Probus DP, Slave

Slave
Modbus RTU

PROFINET I/ O

DNP3 serialV

DNP 3 TCP V

IEC 61850 V

DC24-48;
DC24-48;
PSU Variants
DC60-250/
DC60-250/
AC115-230
AC115-230
Communication

DIGSI

RTD-unit connection
V

20 mA unitVconnection

Synchro Phaser
(IEEE C37.118)

Redundancy
V Protocols

RSTP (Ethernet
ring redundancy)
V
V

PRP V1 (Parallel
Redundancy
Protocol)V
V
V

HSR (High
Ring con
V available Seamless
V
V guration)

Further Ethernet
protocolsV on Ethernet modules
V
V

Time Synchronisation
C

V 1)

V 1)

1)
prole(PSRC - prole)

V 1) IEEE 1588VC37.238

V 1)

V 1)

V 1)

34 Selection Guide for SIPROTEC and Reyrolle Edition 3

Overview, Relay Selection Table

7VU683

7RW80

7RW60

7SR158

SIPROTEC 5

7SG117

Reyrolle

Reyrolle

7VE6

Fault Recorder

Reyrolle

SIPROTEC
600er

7VK61

Voltage and frequency protection


SIPROTEC
Compact

7VK87

High speed
Busbar transfer
SIPROTEC 4

Abbr.

Synchronizing
Reyrolle

Function

SIPROTEC 4

ANSI

Device series

SIPROTEC 5

1) in preparation
2) via CFC
3) = IO number of a standard variant (increased configuration
available using the SIPROTEC 5 system)
4) = number of one unit 7SS60. Total number is depending
on system configuration

Breaker management

SIPROTEC 4

C = basic
V = optional (additional price)
= not available

7SG118

7SG15

7KE85
1/32/1

Hardware Feature
Case (x19'')

1/32/1

1/31/2

1/3; 1/2

1/1

1/6

1/6

Size (xE)

E4

E4

E6

E12, E16

Small Display (lines)

8
320x240

Large, graphical Display (Pixel)

320x240

240x120

240x120

240x120

Push Buttons

Key Switch

LEDs (max)

82

9/16

9/16

16

10

10

82

Pluggable terminal blocks

DC 24-60;
DC 88250/115V

DC 24-60;
DC 88-250

DC 24-60;
DC 88-250

DC24-48;
DC60-250/
AC115-230

PSU Variants

DC 24-48;
DC 24-48;
DC 24-60;
DC 24-48;
DC 60-250/ DC 60-250/ DC 60-250/ DC 88-250
AC 115-230 AC115-230 AC 115-230

DC 24-48;
DC 60-250/
AC 115-230

DC 24-48;
DC24-48;
DC 60-250/ DC60-125
AC115-230 DC110-250/
AC115-230

Communication
Front User Interface

IEC 60870-5-101

IEC 60870-5-103

IEC 60870-5-104

Profibus FMS, Slave

Profibus DP, Slave

Modbus RTU Slave

PROFINET I / O

DNP3 serial

DNP 3 TCP

IEC 61850

DIGSI

RTD-unit connection

20 mA unit connection

Synchro Phaser (IEEE C37.118)

Redundancy Protocols

RSTP (Ethernet ring redundancy)

PRP V1 (Parallel Redundancy Protocol)

HSR (High available Seamless Ring configuration)

Further Ethernet protocols on Ethernet modules

Time Synchronisation

V 1)

V 1)

IEEE 1588 C37.238 profile (PSRC - profile)

35 Selection Guide for SIPROTEC and Reyrolle Edition 3_V1.1

Legal Notice
Indication of conformity

Copyright

This product complies with the directive


of the Council of the European Communities on harmonization of the laws of the
Member States relating to electromagnetic compatibility (EMC Council Directive
2004 / 108 / EC) and concerning electrical equipment for use
within specied voltage limits (Low Voltage Directive
2006 / 95 / EC).

Copyright Siemens AG 2014. All rights reserved.

This conformity has been proved by tests performed


according to the Council Directive in accordance with the
generic standards EN 61000-6-2 and EN 61000-6-4 (for
EMC directive) and with the standard EN 60255-27 (for Low
Voltage Directive) by Siemens AG.

SIPROTEC and DIGSI are registered trademarks of Siemens


AG. Any unauthorized use is illegal. All other designations
in this document can be trademarks whose use by third
parties for their own purposes can infringe the rights of the
owner.

The disclosure, duplication, distribution and editing of this


document, or utilization and communication of the content
are not permitted, unless authorized in writing. All rights,
including rights created by patent grant or registration of a
utility model or a design, are reserved.
Registered trademarks

The device is designed and manufactured for application in


an industrial environment.
The product conforms with the international standards of
IEC 60255 and the German standard VDE 0435.
Disclaimer of liability
This document has been subjected to rigorous technical
review before being published. It is revised at regular
intervals, and any modications and amendments are
included in the subsequent issues. The content of this
document has been compiled for information purposes
only. Although Siemens AG has made best efforts to keep
the document as precise and up-to-date as possible,
Siemens AG shall not assume any liability for defects and
damage which result through use of the information
contained herein.
This content does not form part of a contract or of business
relations; nor does it change these. All obligations of
Siemens AG are stated in the relevant contractual agreements.
Siemens AG reserves the right to revise this document from
time to time.
Document version: 03
Release status: 03.2014

Selection Guide for SIPROTEC and Reyrolle Edition 3 36

Notes

Selection Guide for SIPROTEC and Reyrolle Edition 3 37

Published by and copyright 2014:


Siemens AG
Infrastructure & Cities Sector
Smart Grid Division
Energy Automation
Humboldtstr. 59
90459 Nuremberg
Germany

Printed on elementary chlorine-free bleached paper.

All rights reserved.


If not stated otherwise on the individual pages of this
catalog, we reserve the right to include modifications,
especially regarding the stated values, dimensions
and weights. Drawings are not binding.

All product designations used are trademarks or


product names of Siemens AG or other suppliers.
If not stated otherwise, all dimensions in this
catalog are given in mm.

Subject to change without prior notice.


The information in this document contains general
descriptions of the technical options available, which
may not apply in all cases. The required technical
options should therefore be specified in the contract.

For all products using security features of OpenSSL the


following shall apply:
This product includes software developed by the
OpenSSL Project for use in the OpenSSL Toolkit.
(http://www.openssl.org/)
This product includes cryptographic software written
by Eric Young (eay@cryptsoft.com)

For more information, please contact

Order No. IC1000-K4456-A101-A3-7600

our Customer Support Center.

Printed in Germany

Tel.: +49 180 524 84 37

Dispo 06200 SIMC-0000-43397

Fax: +49 180 524 24 71

KG 0314 2.5 42 En

(Charges depending on provider)

7500 / 52191 W

E-mail: support.ic@siemens.com
www.siemens.com/protection

Вам также может понравиться