EE6211 - ELECTRICAL CIRCUITS LAB


LIST OF EXPERIMENTS (SYLLABUS )

LIST OF EXPERIMENTS
1. Experimental verification of Kirchhoffs voltage and current laws
2. Experimental verification of network theorems (Thevenin, Norton, Superposition and maximum power
transfer Theorem).
3. Study of CRO and measurement of sinusoidal voltage, frequency and power factor.
4. Experimental determination of time constant of series R-C electric circuits.
5. Experimental determination of frequency response of RLC circuits.
6. Design and Simulation of series resonance circuit.
7. Design and Simulation of parallel resonant circuits.
8. Simulation of low pass and high pass passive filters.
9. Simulation of three phases balanced and unbalanced star, delta networks circuits.
10. Experimental determination of power in three phase circuits by two-watt meter method.
11. Calibration of single phase energy meter.
12. Determination of two port network parameters.

www.Vidyarthiplus.com

www.Vidyarthiplus.com

INDEX
S.NO

DATE

NAME OF EXPERIMENT

Page
No

Verification of ohms & kirchoffs law.

Verification of Thevenins and Norton theorem.

15

Verification of reciprocity theorem.

27

Verification of superposition theorem.

31

Maximum power transfer theorem.

37

Transient Response of RC Circuits for DC input

41

10

11

12

Frequency response of series & Parallel


resonance circuit.
Design and Simulation of series resonance
circuit
Design and Simulation of parallel resonant
circuits
Simulation of low pass and high pass passive
filters
Simulation of three phases balanced and
unbalanced star, delta networks circuits.
Experimental determination of power in three
phase circuits by two-watt meter method

57

63

67

71

79

Calibration of single phase energy meter.

83

14

Determination of two port network parameters

87

Study of CRO and measurement of sinusoidal


voltage, frequency and power factor

www.Vidyarthiplus.com

Signature

47

13

15

Marks

93

www.Vidyarthiplus.com

www.Vidyarthiplus.com

www.Vidyarthiplus.com

Circuit Diagram:

OHM'S Law
S.No.

Voltage Current Resistance

1
2
3
4
5

FOEMULAE USED:

V=IR
WHERE V - VOLTAGE
I- CURRENT
R-RESISTANCE
www.Vidyarthiplus.com

www.Vidyarthiplus.com

EXP.NO: 1
DATE:

VERIFICATION OF OHMS LAW, KVL AND KCL


(a) VERIFICATION OF OHMS LAW
AIM
To verify the ohms law for the given electrical circuit
APPARATUS REQUIRED
Sl.
No

Name of the apparatus

Range

Type

Quantity

Regulated power supply

(0 - 30) V

Analog

Voltmeter

(0 - 30) V

MC

Resistor

1 k, 1 W

Bread board

Connecting wires

As
Required

Statement:
Ohms law: Ohms law states that At constant temperature, the steady current flowing
through the conductor is directly proportional to the potential difference across the two ends
of the conductor.
Procedure:1. Connections are made as per the circuit diagram
2. By Varying the Input Voltage , the voltage and the corresponding current values
are noted down for the given Resistor.

www.Vidyarthiplus.com

www.Vidyarthiplus.com

3. Repeat the same procedure for different values of Resistors.

www.Vidyarthiplus.com

www.Vidyarthiplus.com

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

www.Vidyarthiplus.com

RESULT:
Thus Ohms law has been verified.

www.Vidyarthiplus.com

10

www.Vidyarthiplus.com

CIRCUIT DIAGRAM:
(0-30V)

(0-30V)

(0-30V)

+ V -

1k
R2

1k
R1

1k
R3

+
(0-30V)

(0 - 30V)

TABULAR COLUMN:-

S.No

Voltage

Voltage

Voltage V2

(V)

V1 (V)

(V)

Total voltage
Voltage V3
(V)

www.Vidyarthiplus.com

Vt

= V 1+V 2+V3 (V)

Theoretical

Practical

11

www.Vidyarthiplus.com

(b) VERIFICATION OF KIRCHOFFS VOLTAGE LAW


AIM
To verify the kirchoffs voltage law for the given electrical circuit

APPARATUS REQUIRED
Sl.
No

Name of the apparatus

Range

Type

Quantity

Regulated power supply

(0 - 30) V

Analog

Voltmeter

(0 - 30) V

MC

Resistor

1 k, 1 W

Bread board

Connecting wires

As
Required

KIRCHOFFS VOLTAGE LAW


In any closed circuit the sum of potential drop is equal to the sum potential rise.
PROCEDURE
1. Make the connections as per the circuit diagram
2. Switch on the power supply
3. Vary the RPS to a specified voltage and note down the corresponding voltage
readings across resistors
4. Repeat the above step for various RPS voltages and tabulate the readings

THEORETICAL CALCULATION:
www.Vidyarthiplus.com

12

www.Vidyarthiplus.com

www.Vidyarthiplus.com

13

www.Vidyarthiplus.com

RESULT:
Thus Kirchoffs voltage law has been verified.

www.Vidyarthiplus.com

14

www.Vidyarthiplus.com

CIRCUIT DIAGRAM:

(0-20mA)
+ A

(0-20mA)

R1 = 1k

R3 = 1k

(0-30V)

(0-30V)

RPS

(0-20mA)

R2 = 1k

TABULAR COLUMN:-

S.No

Current I1

Current I2

Current I3

(mA)

(mA)

(mA)

www.Vidyarthiplus.com

Current I1= I2 + I3
Theoretical

practical

15

www.Vidyarthiplus.com

(c) VERIFICATION OF KIRCHOFFS CURRENT LAW


AIM:
To verify Kirchoffs current law for the given circuit

APPARATUS REQUIRED:
Sl.
No

Name of the apparatus

Range

Type

Quantity

Regulated power supply

(0 - 30) V

Analog

Voltmeter

(0 - 30) V

MC

Ammeter

(0 - 20) mA

MC

Resistor

1 k,1 W

Bread board

Connecting wires

As
Required

KIRCHOFFS CURRENT LAW


The algebraic sum of the current meeting at any junction or node is zero. In other
words, the sum of the current flowing towards a junction is equal to the sum of the current
leaving the junction.
PROCEDURE:
1. Make the connections as per the circuit diagram
2. Switch on the power supply
3. Vary the RPS to a specified voltage and note down the corresponding ammeter
readings
4. Repeat the above step for various RPS voltages and tabulate the readings

www.Vidyarthiplus.com

16

www.Vidyarthiplus.com

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

17

www.Vidyarthiplus.com

RESULT:
Thus the Kirchoffs current law has been verified.
-

www.Vidyarthiplus.com

18

www.Vidyarthiplus.com

CIRCUIT DIAGRAM 1:
R1 = 1k

(0-30V)
RPS

R3 = 1k

R2 = 1k

RL= 1k

CIRCUIT DIAGRAM 2:
DETERMINATION OF THEVENIN VOLTAGE (Vth)
R1 = 1k

R3 = 1k

(0-30V)
RPS

R2 = 1k

(0-30V)

V
-

CIRCUIT DIAGRAM 3:
DETERMINATION OF LOAD CURRENT (IL)
R1= 1k

R3= 1k

+
(0-30V)
RPS

RL= 1k
R2= 1k

(0-20mA)

A
-

www.Vidyarthiplus.com

19

www.Vidyarthiplus.com
EXP.NO : 2
DATE :

VERIFICATION OF THEVENIN AND NORTON THEOREM


(i) VERIFICATION OF THEVENIN THEOREM
AIM
To verify the Thevenin theorem for the given electrical circuit

APPARATUS REQUIRED
Sl.
No

Name of the apparatus

Range

Type

Quantity

(0 - 30) V

Analog

Regulated power supply

Ammeter

(0 - 30) mA

MC

Voltmeter

(0 - 30) V

MC

Resistor

1 k

Bread board

Connecting wires

Required

THEVENINS THEOREM
Any linear active network with output terminal A and B can be replaced by an
equivalent circuit with a single voltage source Vth (thevenins voltage) in series with Rth
(thevenins resistance)
Vth - open circuit voltage across terminal A & B
Rth equivalent resistance obtained by looking back the circuit through the open
circuit terminal A and B
THEORETICAL CALCULATION
Thevenins voltage, Vth = V [R2 / (R 1 + R 2)] Volts
www.Vidyarthiplus.com

20

www.Vidyarthiplus.com

CIRCUIT DIAGRAM 4:
DETERMINATION OF Rth
R3 = 1k

R1 = 1k

R2 = 1k

Rth

CIRCUIT DIAGRAM 5:
THEVENIN EQUIVALENT CIRCUIT:

DRB

Rth

RPS
Vth

RL = 1k

www.Vidyarthiplus.com

21

www.Vidyarthiplus.com

PROCEDURE:
To determine Thevenins voltage, Vth
1. Make the connections as per the circuit diagram
2. Switch on the power supply
3. Vary the regulated power supply to a specified voltage and note down the
corresponding voltmeter readings
4. Repeat the previous step for different voltage by varying the RPS.
5. Switch off the power supply
To determine of load current, IL
1. Make the connections as per the circuit diagram
2. Switch on the power supply
3. Vary the regulated power supply to a specified voltage and note down the
corresponding ammeter readings
4. Repeat the previous step for different voltage by varying the RPS.
5. Switch off the power supply

www.Vidyarthiplus.com

22

www.Vidyarthiplus.com

TABULAR COLUMN:-

S.No

Voltage
(V)

Thevenins Voltage
(VTh)
Practical
(V)

Theoretical
(V)

Load current (IL)


Practical
(I)

Theoretical
(I)

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

23

www.Vidyarthiplus.com

RESULT:
Thus the Thevenins theorem was verified for the given electrical circuit.
Theoretical:
Vth =
Rth =
IL =
Practical:
Vth =
Rth =
IL =

www.Vidyarthiplus.com

24

www.Vidyarthiplus.com

CIRCUIT DIAGRAM
R3= 1k

R1= 1k

(0-30V)
RPS

R2= 1k

RL= 1k

CIRCUIT DIAGRAM :
DETERMINATION OF Rth

R3 = 1k

R1 = 1k

Rth

R2 = 1k

DETERMINATION OF (IL)

R3 = 1k

R1 = 1k

RL= 1k

(0-30V)
RPS

R2= 1k

(0-20mA)

A
-

EQUIVALENT CIRCUIT:

Isc
-

Rth

www.Vidyarthiplus.com

RL = 1k

25

www.Vidyarthiplus.com

VERIFICATION OF NORTON THEOREM


AIM:
To verify the Norton theorem for the given electrical circuit.
APPARATUS REQUIRED
Sl.
No

Name of the apparatus

Range

Type

Quantity

(0 - 30) V

Analog

Regulated power supply

Ammeter

(0 - 30) mA

MC

Voltmeter

(0 - 30) V

MC

Resistor

1 k

Bread board

Connecting wires

As
Required

NORTON THEOREM
Any linear active network with output terminals A & B can be replaced by an
equivalent circuit with a single current source I in parallel with Rth ( Thevenin equivalent
resistance)
Where Rth is the equivalent resistance obtained by looking back the circuit through the
open terminal A & B
FORMULAE
IL = ISC * ( Rth / (Rth + RL))
where,ISC - Norton equivalent current source in amperes
IL

- Current through the load in amperes

Rth - Thevenins equivalent resistance in ohms


RL - Load resistance in ohms

www.Vidyarthiplus.com

26

www.Vidyarthiplus.com

TABULAR COLUMN:Isc
S.No

Voltage
(V)

Practical
(mA)

Theoretical
(mA)

Load current (IL)


Practical
(mA)

Theoretical
(mA)

V L = IL * RL
www.Vidyarthiplus.com

27

www.Vidyarthiplus.com

PL = IL2 * RL

PROCEDURE :
1. The connections are given as per the circuit diagram
2. Switch on the power supply
3. The current in short circuited branch is noted using the ammeter
4. Tabulate the readings and check with the theoretical values

Determination of load current


1. Make the connections as per the circuit diagram
2. Switch on the power supply
3. Vary the RPS to a specified voltage and note the corresponding ammeter reading
4. Repeat the above step for various RPS voltages and tabulate the reading

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

28

www.Vidyarthiplus.com

www.Vidyarthiplus.com

29

www.Vidyarthiplus.com

RESULT
Thus Norton theorem was verified for the given electrical circuit.
Theoretical:
Isc =
Rth =
IL =
Practical:
Isc =
Rth =
IL =

www.Vidyarthiplus.com

30

www.Vidyarthiplus.com

CIRCUIT DIAGRAM 1:
R3= 1k

R1= 1k

(0-30V)
RPS

R2= 1k

RL= 1k

CIRCUIT DIAGRAM 2:
CASE A:
R1 = 1k

R3 = 1k

(0-30V)
RPS

R2 = 1k

(0-10mA)

CIRCUIT DIAGRAM 3:
CASE B:
R1 = 1k

R3 = 1k

+
(0-10mA)

R2 = 1k

(0-30V)
RPS

www.Vidyarthiplus.com

31

www.Vidyarthiplus.com
EXP.NO :3
DATE :

VERIFICATION OF RECIPROCITY THEOREM


AIM:
To practically verify the reciprocity theorem for the network with the theoretical
calculation.

APPARATUS REQUIRED:
S.NO

Components

Type / Range

Quantit
y

Regulated power supply

(0-30)V

Resistor

1k

Ammeter

MC (0-30)mA

Bread board

Wires

THEORY:
In any linear bilateral network the ratio of voltage to current response, in any
element to the input is constant even when the position of the input and output are
interchanged.
PROCEDURE:
1.

Connections are made as per the circuit diagram.

2.

Note down the ammeter reading and find the ratio of output current and input
voltage.

3.

Interchange the position of ammeter and voltage source.

4.

Note down the ammeter reading and find the ratio of output and input voltage.

5.

Compare this value with the value obtained in step 2.

www.Vidyarthiplus.com

32

www.Vidyarthiplus.com

www.Vidyarthiplus.com

33

www.Vidyarthiplus.com

TABULAR COLUMN:Case A
S.No Voltage (V) Voltage V
1
(V)

Case B

Current
I2 (mA)

Voltage V 2
(V)

Current I1
(mA)

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

34

www.Vidyarthiplus.com

RESULT:
The reciprocity theorem was verified for given network with the theoretical
calculation.

www.Vidyarthiplus.com

35

www.Vidyarthiplus.com

CIRCUIT DIAGRAM 1:
CASE 1: When both voltage sources E1 and E2 are present
R3 = 1k

R1 = 1k

RL= 1k

(0-30V)
RPS

(0-30V)
RPS

(0-20mA)

A
-

CIRCUIT DIAGRAM 2:
CASE 2: When voltage source E1 is present
R1 = 1k

(0-30V)
RPS

R3 = 1k

RL= 1k
+

(0-20mA)

A
-

CIRCUIT DIAGRAM 3: CASE 3: When voltage source E2 is present


R3 = 1k

R1 = 1k

RL= 1k

(0-30V)
RPS

(0-20mA)

www.Vidyarthiplus.com

36

www.Vidyarthiplus.com
EXP.NO: 4
DATE:

VERIFICATION OF SUPERPOSITION THEOREM


AIM:
To practically verify superposition theorem for the given network with the theoretical
calculation.
APPARATUS REQUIRED:
S. No

Components

Type/Range

Qty

1.

Regulated supply

(0 - 30)V

2.

Resister

1k

4.

Ammeter

(0-20mA)

5.

Bread board

6.

Wires

As Required

THEORY:
In a linear bilateral active network containing more than one source the total response
obtained is algebraic sum of response obtained individually considering only one source at a
time the source being suitable suppressed.
PROCEDURE:
1.

The connection is made as per the circuit diagram.

2.

With V1 = 20V and V 2 = 0V observe the ammeter reading.

3.

The above procedure repeated with V1 = 0V and V2 = 20V.

4.

The total response at the required terminal is obtained using sum of individual
response.

5.

Respect same procedure for different values of V1 and V2.

www.Vidyarthiplus.com

37

www.Vidyarthiplus.com

www.Vidyarthiplus.com

38

www.Vidyarthiplus.com

TABULAR COLUMN:CASE 1: When both voltage sources E1 and E2 are present.


Current I
S.No

Voltage E1 (V)

Voltage E2 (V)
Practical

(I)

Theoretical (I)

TABULAR COLUMN:CASE 2: When voltage source E1 is present. [Circuit Diagram 2]


Current I
S.No

Voltage E1 (V)
Practical

(I)

www.Vidyarthiplus.com

Theoretical (I)

39

www.Vidyarthiplus.com

TABULAR COLUMN:CASE 3: When voltage source E1 is present. [Circuit Diagram 3]


Current I
S.No

Voltage E2 (V)
Practical

(I)

Theoretical (I)

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

40

www.Vidyarthiplus.com

RESULT:
Thus superposition theorem was verified theoretically and experimentally.

www.Vidyarthiplus.com

41

www.Vidyarthiplus.com

CIRCUIT DIAGRAM 1:
R3= 1k

R1= 1k

(0-30V)
RPS

R2= 1k

RL= 1k

CIRCUIT DIAGRAM 2:
DETERMINATION OF THEVENIN VOLTAGE (Vth)
R3 = 1k

R1 = 1k

(0-30V)
RPS

R2 = 1k

(0-30V)

V
-

CIRCUIT DIAGRAM 3:
DETERMINATION OF Rth
R1= 1k

(0-30V)
RPS

R3= 1k

R2= 1k

Rth

EXP.NO : 5

www.Vidyarthiplus.com

42

www.Vidyarthiplus.com
DATE :

VERIFICATION OF MAXIMUM POWER TRANSFER THEOREM


AIM:
To verify the maximum power transformation in purely passive circuit and the
load resistance is variable.
APPARATUS REQUIRED:
Components

Type / Range

Quantity

Resistor

1k

4 Nos

voltmeter

(0-30V)MC

RPS

(0-30V)

S.No

THEORY:
Maximum power will be delivered from a voltage source to a load, if load resistance is
equal to the internal resistance of the sources.
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. Remove the load resistor on the network
3. Calculated RTH by substituting all sources with their internal resistances
looking back at the network.
4. Calculate VTH, the open circuit voltage between the terminals by replacing all
the sources to their original position.

www.Vidyarthiplus.com

43

www.Vidyarthiplus.com

FORMULAE:
2

V
Maximum Power th watts
RL

Where Vth - Thevenin voltage


RL-Load resistor
TABULAR COLUMN:Thevenins voltage Vth
S.No

Voltage
(V)

Practical
Voltage

Theoretical
Voltage

Maximum power
delivered=[Vth2/RL]Watts

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

44

www.Vidyarthiplus.com

RESULT:
Thus the maximum power transfer theorem was verified theoretically and
experimentally.

www.Vidyarthiplus.com

45

www.Vidyarthiplus.com

RC Transients :-

S. No.

T(ms) V (t) Amps.

1
2
3
4
5

www.Vidyarthiplus.com

46

www.Vidyarthiplus.com
Ex No. : 06
Date

TRANSIENT RESPONSE OF RL AND RC CIRCUITS FOR DC INPUT


AIM:
To obtain the transient response of RL and RC circuits for dc input
APPARATUS REQUIRED:
S. No.

Components

Type/Range
( 0-15 )V

Qty.

Regulated power supply

2 Nos.

SPST (single pole single throw switch)

Resistor

100

2 No

Capacitor

0.01 F

1 No

Stop watch

1 No

DPST

1 No

1 No

THEORY:
Electrical devices are controlled by switches which are closed to connect supply to the
device, or opened in order to disconnect the supply to the device. The switching operation
will change the current and voltage in the device. The purely resistive devices will allow
instantaneous change in current and voltage.
An inductive device will not allow sudden change in current and capacitance device
will not allow sudden change in voltage. Hence when switching operation is performed in
inductive and capacitive devices, the current & voltage in device will take a certain time to
change from pre switching value to steady state value after switching. This phenomenon is
known as transient.
The study of switching condition in the circuit is called transient analysis.The state of
the circuit from instant of switching to attainment of steady state is called transient state. The

www.Vidyarthiplus.com

47

www.Vidyarthiplus.com

www.Vidyarthiplus.com

48

www.Vidyarthiplus.com

time duration from the instant of switching till the steady state is called transient period. The
current & voltage of circuit elements during transient period is called transient response.

PROCEDURE:
1. Charge on capacitor is o initially.
2. If there is a charge in it, short circuit the terminal then the charge will be dissipated.
3. Close the switch at t = 0
4. Simultaneously switch on the stop watch.
5. For every 2 seconds note down the voltage across capacitor until
Voltmeter reaches 5 V.After reaching 15V allow 10 sec. for it.

THEORETICAL VERIFICATION:
R-L Circuit:
V.
15
S

= Ri + L

di
dt

= R I(S) + L S I(s)

R-C Circuit;
V. = Ri +

1
idt
C

15
= I (s)
S

10 8
100
s

www.Vidyarthiplus.com

49

www.Vidyarthiplus.com

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

50

www.Vidyarthiplus.com

RESULT:
Thus, the transient response of RC circuits for dc input was obtained .

www.Vidyarthiplus.com

51

www.Vidyarthiplus.com

CIRCUIT DIAGRAM
250mH

FG

(0-30)MHz

1F

1k

CRO

Input voltage, V = ..V

TABULAR COLUMN:-

in

Voltage Gain

S.No Frequency (Hz) Voltage (Vo)

= 20 log V /Vin
0

www.Vidyarthiplus.com

52

www.Vidyarthiplus.com

Ex No. :07
Date

FREQUENCY RESPONSE OF SERIES AND PARALLEL RESONANCE


CIRCUITS
(a) FREQUENCY RESPONSE OF SERIES RLC CIRCUIT
AIM
To determine and obtain the frequency response of a series RLC circuit
APPARATUS REQUIRED
Sl. No

Name of the apparatus

Range

Type

Quantity

Decade Resistance Box

1 k

Decade Inductance Box

250 mH

Decade Capacitance Box

1 F

Function Generator

(0 - 3) MHz

C.R.O.

Analog

Bread Board

Connecting wires

Required

THEORY
An A.C. circuit is said to be in resonance with its power factor becomes unity at which
the impedance of circuit becomes purely resistive. The frequency at which such condition
occurs is called resonant frequency. At resonance the circuit current is maximum for series
resonant.
FORMULAE
Resonant frequency, F0 = 1 / [ 2 LC ]
Band width = F2 F1
Quality factor = W0 L / R Where, F0 Resonant frequency

www.Vidyarthiplus.com

53

www.Vidyarthiplus.com

Model graph:

F1 Lower cut off frequency in Hz


F2 Upper cut off frequency in Hz

www.Vidyarthiplus.com

54

www.Vidyarthiplus.com

PROCEDURE:
1. Make the connections as per the circuit diagram
2. Set the values of R, L & C
3. Frequency varied from 1kHz to 100 kHz in steps
4. At each step the frequency and voltage is noted down
5. Graph is drawn between frequency along X axis and voltage along Y axis

www.Vidyarthiplus.com

55

www.Vidyarthiplus.com

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

56

www.Vidyarthiplus.com

RESULT:
Thus the frequency response of series resonant circuit was obtained
www.Vidyarthiplus.com

57

www.Vidyarthiplus.com

www.Vidyarthiplus.com

58

www.Vidyarthiplus.com

CIRCUIT DIAGRAM

FG

(0-30)MHz

TABULAR COLUMN:-

1F

250mH

1k

CRO

Input voltage, Vin = ..V

Voltage Gain

S.No Frequency (Hz) Voltage (Vo)

= 20 log V /Vin
0

www.Vidyarthiplus.com

59

www.Vidyarthiplus.com

(B) FREQUENCY RESPONSE OF PARALLEL RLC CIRCUIT


AIM
To determine and obtain the frequency response of parallel R L C circuit
APPARATUS REQUIRED
Sl.
No

Name of the apparatus

Range

Type

Quantity

Decade Resistance Box

1 k

Decade Inductance Box

250 mH

Decade Capacitance Box

2 F

Function Generator

(0 - 3) MHz

C.R.O.

Analog

Bread Board

Connecting wires

Required

THEORY
An A.C. circuit is said to be in resonance when its power factor becomes unity. The
impedance of circuit at resonance becomes purely resistive. The frequency at which such a
condition occurs is called resonant frequency.
The impedance is given by Z = R + j (XL - XC)
When the impedance is real, the | Z | is minimum. At resonance the power factor is unity
Therefore, Z = R and reactive part is zero. Thus XL - XC = 0
0 = 1 / LC
f0 = 1 / 2 LC

www.Vidyarthiplus.com

60

www.Vidyarthiplus.com

MODEL GRAPH:

THEORETICAL CALCULATION:

www.Vidyarthiplus.com

61

www.Vidyarthiplus.com

FORMULAE USED:
Resonant frequency, f0 = 1 / 2 LC
Band width

= F2 F1

Quality factor

= 0L / R

Where,
f0 Resonant frequency in Hz
F1 Lower cut off frequency in Hz
F2 Upper cut off frequency in Hz

PROCEDURE
1. Make the connections as per the circuit diagram
2. Set the values of R, L & C
3. Frequency varied from 1kHz to 100 kHz in steps
4. At each step the frequency and voltage is noted down
5. Graph is drawn between frequency along X axis and voltage along Y axis

RESULT
The frequency response of a parallel R.L.C. circuit was obtained.

www.Vidyarthiplus.com

62

www.Vidyarthiplus.com

SIMULATION DIAGRAM

www.Vidyarthiplus.com

63

www.Vidyarthiplus.com
EXP.NO: 08
DATE:

DESIGN AND SIMULATION OF SERIES RESONANCE CIRCUIT

AIM
To design and simulation of series resonance circuit using pspice and matlab

SOFTWARE REQUIRED
Orcad-Pspice
Matlab
PROCEDURE
Pspice

1. Build the schematic shown in Figure 1.


2. Vm is an AC voltage source (VAC) from the source library. It needs to be set for 1 volt.
3. L1 is an ideal inductor from the Analog Library. Set for 1000mH.
4. R is an ideal resistor from the Analog Library. Set value to {Rx}. Next add part named
Parameters. Then double click on part to enter edit mode. Click on new column, name = Rx, value
= 200. Then click on column, select display and click on name and value.
5. C1 is an ideal capacitor from the Analog library. Change the value to 40pF.

PSPICE SIMULATION PROFILE SETTINGS


1. Do analysis setup
a. At top of screen click on Pspice
b. Click on New Simulations Profile
c. Type name of profile that you wish.
d. Under Analysis tab, select AC sweep from the Analysis type pull down menu.
e. Under AC Sweep Type

www.Vidyarthiplus.com

64

www.Vidyarthiplus.com

Fig. a

Fig.b
Fig.(a)&(b) Result of input impedance of series RLC tank circuit

www.Vidyarthiplus.com

65

www.Vidyarthiplus.com
2.Select Logarithmic and Decade as shown.

i. Start freq = 100


ii. End freq = 10Meg
iii. Points/Decade = 101
f. Then click the run Pspice button. (Looks like a play button)
g. After running, look at schematic file and click on trace, add trace.
h. Next Select Db() on left, select M() on left, select V(Vm:+), then divide by M(I(Vm)).

3. Use the same circuit as above, and from the Pspice button, Markers, Advanced, select db magnitude of
current marker and Phase of Current marker, and place in series next to L1.

Fig. Simulation Profile Settings

www.Vidyarthiplus.com

66

www.Vidyarthiplus.com

Fig. Series Resonance Circuit

www.Vidyarthiplus.com

67

www.Vidyarthiplus.com
MATLAB
Input impedance of series RLC tank circuit

disp('starting the function of Zinput_seriesRLC1');


%define all the component values and units for Tank
Vm=1; %volts
R=200; %ohms
C=40e-12; %Farads
L=1000e-6; %Henrys
%define the input impedance
Zin_numb=[L*C R*C 1];
Zin_de=[0 C 0];
Zinput=tf(Zin_numb,Zin_de)
figure(1)
bode(Zinput)
title('Input impedance of series RLC tank circuit')
%calculating important parameters of the tank
[z,p,k]=zpkdata(Zinput,'v');
wo=sqrt(1/L/C)
Beta=R/L
Q=wo/Beta
disp(' finished the function of Zinput_seriesRLC1');

Result

Thus the series resonance circuit was designed and simulated using Pspice and Matlab

www.Vidyarthiplus.com

68

www.Vidyarthiplus.com

Pspice Simulation Diagram of Parallel Resonant Circuit

Output

www.Vidyarthiplus.com

69

www.Vidyarthiplus.com
EXP.NO:09
DATE:

DESIGN AND SIMULATION OF PARALLEL RESONANCE CIRCUIT

AIM
To design and simulation of parallel resonance circuit using orcad - Pspice and Matlab
SOFTWARE REQUIRED

Orcad-Pspice

PROCEDURE
Pspice
1.
2.
3.
4.
5.

Build the schematic shown in Figure 1.


Apply the IAC, because we want to plot the frequency response
Set ACMAG =0.001 in IAC
L1 is an ideal inductor from the Analog Library. Set for 1H.
R is an ideal resistor from the Analog Library. Set value to {Rx}. Next add part named
Parameters. Then double click on part to enter edit mode. Click on new column, name = Rx, value
= 200. Then click on column, select display and click on name and value.
6. C1 is an ideal capacitor from the Analog library. Change the value to 100nF.

PSPICE SIMULATION PROFILE SETTINGS


1. Do analysis setup
a. On the ORCAD Capture CIS menu select new simulation profile
b. Choose AC Sweep/Noise in the Analysis type menu
c. Set the Start Frequency at 100, the End Frequency at 10Meg and the Points/Decade at 101
d. Make sure Logarithmic is selected and set to Decade
e. Click OK
2. Use the same circuit as above and place the db magnitude of voltage marker
and the phase of voltage marker in series next to output capacitor.

www.Vidyarthiplus.com

70

www.Vidyarthiplus.com

Fig. Matlab output for input impedance for parallel resonance circuit

www.Vidyarthiplus.com

71

www.Vidyarthiplus.com
MATLAB
Input impedance of Parallel RLC tank circuit

function [Zinput]=Zinput_parallelRLC1()
disp('Starting the function of Zinput_seriesRLC1');
Im =0.0001;
R=20000;
C=100e-09;
L=0.1;
Zinductor=tf([L 0],[0,1]);
Zcapacitor=tf([0 1], [C 0]);
Zinput=1/(1/R+1/Zcapacitor+1/Zinductor)
figure(1)
bode(Zinput)
title('Input impedance of parallel RLC tank circuit')
[z,p,k]=zpkdata(Zinput,'v');
w0=sqrt(1/L/C)
Beta=1/R/C
Q=w0/Beta
disp('finished the function of Zinput_seriesRLC1');

Result

Thus the parallel resonance circuit was designed and simulated using Pspice and Matlab

www.Vidyarthiplus.com

72

www.Vidyarthiplus.com

Fig.1.a.Circuit diagram

Fig.1.b.Output for above circuit


Fig.1.Low Pass Passive Filter

www.Vidyarthiplus.com

73

www.Vidyarthiplus.com
EXP.NO:10
DATE:
SIMULATION OF LOW PASS AND HIGH PASS PASSIVE FILTERS
AIM
To design and simulation of low pass and high passive filter using P-spice

SOFTWARE REQUIRED

Orcad Pspice

PROCEDURE
(a) Low Pass Passive Filter
Pspice
1.
2.
3.
4.

Build the schematic shown in Figure 1.


Apply the VAC, set VAC to 1.
R is an ideal resistor from the Analog Library. Set value to 1k
C is an ideal capacitor from the Analog library. Change the value to 0.1u.

This is a classical low pass filter with RC cut off frequency (-3db) that can be estimated by the formula fc=
(6.28*R*C), and in our case fc=1 / (6.28*0.1*1k)=1.59khz, where we express the capacitances in uF,
resistance in kohm and frequency in khz

PSPICE SIMULATION PROFILE SETTINGS


1. Do analysis setup
a. On the ORCAD Capture CIS menu select new simulation profile
b. Choose AC Sweep/Noise in the Analysis type menu
c. Set the Start Frequency at 10, the End Frequency at 1Meg and the Points/Decade at 10
d. Make sure Logarithmic is selected and set to Decade
e. Click OK
2. Use the same circuit as above and place the voltage marker and the db of voltage marker

www.Vidyarthiplus.com

74

www.Vidyarthiplus.com

Fig.2.a.Circuit diagram

Fig.2.b.Output for above circuit


Fig2 .High Pass Passive Filter

www.Vidyarthiplus.com

75

www.Vidyarthiplus.com
High Pass Passive Filter
Pspice
1.
2.
3.
4.

Build the schematic shown in Figure 1.


Apply the VAC, set VAC to 1.
R is an ideal resistor from the Analog Library. Set value to 1k
C is an ideal capacitor from the Analog library. Change the value to 0.1u.

This is a classical low pass filter with RC cut off frequency (-3db) that can be estimated by the formula fc=
(6.28*R*C), and in our case fc=1 / (6.28*0.1*1k)=1.59khz, where we express the capacitances in uF,
resistance in kohm and frequency in khz

Result

Thus the passive low pass and high pass filter was designed and simulated using Pspice .

www.Vidyarthiplus.com

76

www.Vidyarthiplus.com

Fig. Three-Phase Circuits with Line and Load Impedances

Fig. Pspice circuit for Three-Phase Circuits with Line and Load Impedances

www.Vidyarthiplus.com

77

www.Vidyarthiplus.com
EXP.NO:11
DATE:
SIMULATION OF THREE PHASES BALANCED AND UNBALANCED STAR, DELTA
NETWORKS CIRCUITS
AIM
To build, simulate, and analyze three-phase circuits using OrCAD Capture Pspice Schematics under
balanced and unbalanced conditions, and to understand the characteristic of 3-phase power transmission
circuits
SOFTWARE REQUIRED

Orcad Pspice

Problem:
1 .In Fig, lets assume that the three-phase circuits are balanced and each has a magnitude (peak value) of
170 V at 60Hz in the positive sequence with Va = 170 V 00 . The line impedance is (1 + j10) , and the
load is (20 + j20). Find: a) the line currents (Ia, Ib, Ic) and the neutral current (In) in peak values b) the power
loss in each line, including the neutral c) the power factor for each phase of the load

2. Repeat problem for given figure, but lets now assume that the three-phase circuits are unbalanced and
operating in the positive sequence with Va = 170 V 00 . Use the same line impedance, but the load is now
(20 + j20) for phase A, (50 + j10) for phase B, and (5 + j50) for phase c.

Procedure
1. Three-Phase Balanced Circuits
a. Build the three-phase circuits of Figure 1 onto the Schematic window
b. To get parts, click button on the right hand side menu. Alternatively, you could also get parts by going to
the top menu, click on Place, and then select Part.
c. If no library is shown on the Place Part window, then you will have to manually add the library by
clicking the Add Library button. Look for a library called Source and click on it. The SOURCE
library should now be listed on the Place Part window.
d. The three-phase voltages are made up of three ac sinusoidal single-phase voltage sources Vsin under
the SOURCE library to build the three-phase voltages. Once the Vsin part is on the schematic, double
click on it to assign its parameter values:

www.Vidyarthiplus.com

78

www.Vidyarthiplus.com

Simulation Setting window

www.Vidyarthiplus.com

79

www.Vidyarthiplus.com
AC=0 DC=0 FREQ=60 PHASE=0 VAMPL=170 VOFF=0
Note that the other two Vsin voltages should have the same parameter values as above except their phases
(for V2 and V3) should be -1200 and + 1200, respectively (assuming the phase sequence is positive).
e. Passive components such as Resistor, Inductor, or Capacitor can be found under the ANALOG library.
For the given impedances in the problem 1, determine

the resistor and inductor values. These are the

values that you will need to assign for the Resistors and Inductors on the schematic.
f. Connect a 0/ source ground to the neutral points (node n and N in Figure 1). The ground can be obtained
by clicking on the right side bar menu, and then select 0 /SOURCE in the Place Ground window as
shown in Figure.
g. After the schematic is done, go to Pspice on the top menu, and select New Simulation Profile. A
window appears asking you to name the simulation profile. Type in any name, but preferably something that
relates to your schematic, such as three-phase. Then, hit OK and the following window appears.
j. Enter the following values for the simulation settings and then hit OK: Run to time=1050ms, Start saving
data after=1000ms, Maximum step size=0.1ms Check the box for the Skip the initial transient bias point
calculation (SKIPBP)
k. Run Pspice Simulation by selecting Run under Pspice on the menu. Once the simulation is
completed, a Probe window will appear as shown in Figure. However, if there is an error or more on your
schematic then the simulation will stop. You should then go back to the schematic page and trouble-shoot
the schematic.
l. To show various waveforms (voltage, current, power) from the schematic, go back to the schematic
window and then place the markers or probes to any place of your interest on the schematic. The probes are
located just below the top menu and there are four probes available: voltage (V) , voltage differential (V+V-)
, current (I) and power (W). Note that you should run your simulation again every time you add or remove
probes.
m. To observe the input voltage waveforms, place the Voltage markers on top of each Vsin symbol on your
schematic. This will automatically generate the waveforms on the Probe window. Switch to the Probe
window and you should see the waveforms of balanced three-phase voltages as shown in Figure
n. Remove voltage probes for Phase B and Phase C from the schematic, and add a current probe into Phase
A.

www.Vidyarthiplus.com

80

www.Vidyarthiplus.com

Three Phase
voltage waveform

Voltage and current probes or markers on Phase A

www.Vidyarthiplus.com

81

www.Vidyarthiplus.com
o. Switch back to the Probe Window, you should now see the Phase A voltage and the line current A as
shown in Figure.
p. Rescale the current waveform by a factor of 10 to see the current waveform more clearly. This is done by
double clicking the name of the current waveform (I(R1) in Figure
r. To determine the times when these zero crossings occur, you may use the cursors by clicking on the menu.
There are two cursors which are movable by the use of left click and right click of your mouse. At this point,
the two cursors should be on one of the waveforms. To find out which waveform the cursors are currently
on, look at the names of the waveforms (bottom left of the plot). If the legend of the waveform is surrounded
by a square then the cursors will be assigned to the waveform. Also, if you look at the bottom right of the
plot, you should also see a small window entitled Probe Cursor which shows the location of the cursors (x
and y coordinates) on the plot
s. The Probe Cursor window consists of 3 rows and 2 columns. The first column shows the time in ms and
the second column show the voltage in Volts and/or current in Amps. The third row shows the difference
between the two x-points (row 3 column 1) and the two y points (row 3 column 2). See Figure again. t. Use
the right click of your mouse to move one cursor to find the zero crossing of the voltage as shown in Figure.
Use the left hand click to measure the zero crossing of the current. Note that you wont be able to get exactly
0 for the y points, so do the best you can to get a number close to 0. Ask your instructor to verify your result
and then print it out.
u. From the zero crossing values that you just obtained, measure the power factor as seen by the source, i.e.,
power factor associated with the total impedance of he load and the line. Is it a lagging or leading power
factor?
v. Zoom to fit the plot by clicking on the upper right corner of the plot. Delete both waveforms from the
plot, and plot the neutral current by placing the current probe on the neutral line on the schematic. Observe
the value of the neutral current.
w. Delete the neutral current waveform from the plot, and, instead, add the load voltage from phase A to the
plot. Switch to the Probe Window and you should see the load voltage waveform on the plot.

www.Vidyarthiplus.com

82

www.Vidyarthiplus.com

Voltage and current after rescaling the current waveform

Figure. Zooming in to the zero crossing points

www.Vidyarthiplus.com

83

www.Vidyarthiplus.com
2. Three-Phase Unbalanced Circuits
a. Build a three-phase unbalanced circuit using the same three-phase schematic of part 1. Change the load
impedance to the values listed in Problem 2.
b. Run the simulation and obtain the load voltage waveforms into a single plot. Copy and paste into Word.
Note that because the circuit is unbalanced, the voltage at the load side of the neutral line is not the same as
the voltage at its source side, i.e. at ground level. Hence, to obtain the load voltage waveform, you have to
use the Differential Voltage probe or marker from the menu. With this probe, you will have to place two
markers (since it will be measuring a differential voltage): V+ marker and V- marker. Place the V+ marker
with the first click of your mouse
to the top terminal of load resistor R1a and place the V- marker on the bottom terminal of load inductor L1a.
c. Delete the load voltage waveforms and obtain the input voltage waveforms (i.e., the three phase voltages
at the source side) into a single plot. Copy and paste into Word.
d. Remove the input voltage waveforms and now plot the current waveforms (all line currents and neutral
current) into a single plot. Rescale any current waveform if necessary to make all waveforms visible on the
plot. Copy and paste into Word.
e. Determine the power factor for each phase of the load by measuring the phase difference between the
voltage across and the current through it. Note that the phase difference between the voltage across and the
current through each of the three load phases should be equal (theoretically) to the angle of the
corresponding load impedance.

Result
Thus the three phase circuits (balanced or unbalanced, star or delta) are designed and analyzed
using Orcad Pspice software.

www.Vidyarthiplus.com

84

www.Vidyarthiplus.com

CIRCUIT DIAGRAM

THREE PHASE POWER AND POWER FACTOR MEASUREMENT

www.Vidyarthiplus.com

85

www.Vidyarthiplus.com
EXP. NO. 12
DATE:

MEASUREMENT OF THREE PHASE POWER AND POWER FACTOR

AIM
To conduct a suitable experiment on a 3-phase load connected in star or delta to measure the three phase
power and power factor using 2 wattmeter method.

OBJECTIVES
1.

To study the working of wattmeter

2.

To accurately measure the 3 phase power

3.

To accurately measure the power factor

4.

To study the concept of star connected load and delta connected load

APPARATUS REQUIRED:

S.NO

NAME OF THE APPRATUS

RANGE

QUANTITY

(600V,10A,LPF)

Two element wattmeter

MI Ammeter

(0-10)A

3.

MI voltmeter

(0-600)V

4.

Power Factor meter

5.

Connecting wires

1
Required

FORMULA TO BE USED:

Output power W = W1+W2 in KW

PF = W/( Vp Ip)

Let x revolution / kwh be the rating.

Now x revolution = 1 kwh


= 1* 3600*1000 watt-sec.
Constant k of energymeter = 3600 * 103/ x watt-sec
For each load, indicated power Wi is given as Wi = k/t watts

www.Vidyarthiplus.com

86

www.Vidyarthiplus.com
TABULAR COLUMN:

S.NO

LOAD CURRENT

WATTMETER

INDICATED

I (Amps)

READING,

POWER,

Wa (W)

Wi (W)

Time taken
,

% ERROR

t (secs)

NOTE:
From the calibration curve it is possible to predict the error in recording the energy. So the correction can be applied
to the energy meter reading so that correct energy reading can be obtained and used.

Where

www.Vidyarthiplus.com

87

www.Vidyarthiplus.com
K= energy meter constant (watt-sec)
t = time for 1 revolution(sec)
% error = Wi Wa / Wi * 100
Where Wi is indicated power in watts
Wa is actual power shown by wattmeter in watts
% error can be zero +ve or ve.

PROCEDURE:
1. Switch ON the 3 phase MCB.
2. Vary the load step by step.
3. For each step note down the wattmeter, voltmeter, ammeter readings.
4. Determine the power using the formula.

RESULT:
The Power and Power factor of the given experiment is measured by using two wattmeter methods.

www.Vidyarthiplus.com

88

www.Vidyarthiplus.com
CIRCUIT DIAGRAM

SINGLE PHASE ENERGY METER


TABULAR COLUMN:

S.No

True power KW

No of
revolution

Time

True energy
kWh

Energy
recorded

% error

kWh

www.Vidyarthiplus.com

89

www.Vidyarthiplus.com
EXPT. NO.13
DATE:
CALIBRATION OF SINGLE PHASE ENERGYMETER
AIM:
To calibrate the given single phase energy meter at unity and other power factors
OBJECTIVE:
1. To study the working of energy meter.
2. To accurately calibrate the meter at unity and other power factor.
3. To study the % of error for the given energy meter.
APPARATUS REQUIRED:
S.NO

NAME OF THE APPRATUS

RANGE

QUANTITY

Single-Phase Energy meter

Wattmeter

3.

Stopwatch

4.

M.I Ammeter

(0-5)A

5.

M.I Voltmeter

(0-300)V

6.

Connecting wires

(300V,10A LPF)

1
1

Required

FORMULA TO BE USED:

1. True energy = W*t


2. Energy Recorded = No of revolution /Energy meter constant.
3. %error = (True energy- Energy recorded)/True energy
CONNECTION PROCEDURE:

1. Connect the main supply to the MCB input.


2. Connect voltmeter, Ammeter, in series and parallel with supply.
3. Connect MCB output phase terminal to main M terminal of wattmeter.
4. Connect Line L signal of wattmeter to energy meter 1S terminal.
5. Connect voltage V of wattmeter to supply neutral terminal.
6. Connect main supply neutral to 2S terminal of Energy meter.
7. Connect 2L,1L terminal of Energy meter to RL load terminal L1,L2.

www.Vidyarthiplus.com

90

www.Vidyarthiplus.com

EXPERIMENTAL PROCEDURE:

1. Connections are given as per the circuit diagrams.


2. Switch on the power supply.
3. Vary the load and keep one particular position.
4. Note down the wattmeter readings.
5. Determine the time require to complete the revolution of energy meter.
6. From that find out the actual energy consumed, energy recorded and percentage of error.

THEORY

RESULT:

Thus the given single phase energy meter is calibrated with actual energy consumption and found out the error.

www.Vidyarthiplus.com

91

www.Vidyarthiplus.com

Circuit Diagram

www.Vidyarthiplus.com

92

www.Vidyarthiplus.com
EXP. NO. 14
DATE:
DETERMINATION OF TWO PORT NETWORK PARAMETERS
AIM
To calculate and verify 'Z' ,Y , ABCD, and H parameters of two-port network.
APPARATUS REQUIRED
Sl.
No.

Name of the component

Resistors

2
3
4
5
6
7

Regulated Power Supply (RPS)


Voltmeter
Ammeter
Decade Resistance Box (DRB)
Bread Board
Multi meter

Specifications

Quantity

1K
2K
0-30 V
0-20V
0-20 mA
10W-1MW

2
1
1
1
1
1
1
1

THEORY:
In Z parameters of a two-port, the input & output voltages V1 & V2 can be expressed in terms of input & output
currents I1 & I2. Out of four variables (i.e V1, V2, I1, I2) V1& V2 are dependent variables whereas I1 & I2 are
independent variables. Thus,
V1 = Z11I1+ Z12 I2 -----(1)
V2 = Z21I1 + Z22 I2 -----(2)
Here Z11 & Z22 are the input & output driving point impedances while Z12 & Z21 are the
reverse & forward transfer impedances.

In Y parameters of a two-port, the input & output currents I1 & I2 can be expressed in terms of input & output
voltages V1 & V2 . Out of four variables (i.e I1, I2, V, V2) I1& I2 are dependent variables whereas V1 & V2 are
independent variables.
I1 = Y11V1 + Y12V2 ------(3)
I2 = Y21V1 + Y22V2 -------(4)
Here Y11 & Y22 are the input & output driving point admittances while Y12 & Y21are the
reverse & forward transfer admittances

www.Vidyarthiplus.com

93

www.Vidyarthiplus.com
OBSERVATION TABLE:
Z Parameters
When i/p is open ckt

When o/p is open ckt

S.No
V2

V1

I2

V2

V1

I1

Y Parameters
When i/p is short ckt

When o/p is short ckt

S.No
V2

I1

I2

V1

I1

I2

ABCD Parameters
When o/p is short ckt

When i/p is short ckt

S.No
V1

I1

I2

V2

V1

I2

H Parameters
When o/p is open ckt

When o/p is short ckt

S.No
V1

V2

I1

V1

www.Vidyarthiplus.com

I2

I1

94

www.Vidyarthiplus.com
ABCD parameters are widely used in analysis of power transmission engineering where they are termed as Circuit
Parameters. ABCD parameters are also known as Transmission Parameters. In these parameters, the voltage &
current at the sending end terminals can be expressed in terms of voltage & current at the receiving end.
Thus,
V1 = AV 2 + B (-I2) ---------(5)
I1 = CV2 + D (-I2) -----------(6)
Here A is called reverse voltage ratio, B is called transfer impedance C is called
transfer admittance & D is called reverse current ratio.

In h parameters of a two port network, voltage of the input port and the current of the
output port are expressed in terms of the current of the input port and the voltage of the
output port. Due to this reason, these parameters are called as hybrid parameters, i.e. out
of four variables (i.e. V1, V2, I1, I2) V1, I2 are dependent variables.
Thus,
V1= h11I1 + h12V2 ------------- (1)
I2 = h21I1 + h22V22 ----------- (2)
H11 and H22 are input impedance and output admittance.
H21 and H12 are forward current gain and reverse voltage gain

PROCEDURE:
Z-Parameter
(1) Connect the circuit as shown in fig. & switch ON the experimental board.
(2) First open the O/P terminal & supply 5V to I/P terminal. Measure O/P Voltage & I/P Current.
(3) Secondly, open I/P terminal & supply 5V to O/P terminal. Measure I/P Voltage & O/P current using multi-meter.
(4) Calculate the values of Z parameter using Equation (1) & (2).
(5) Switch OFF the supply after taking the readings.

www.Vidyarthiplus.com

95

www.Vidyarthiplus.com
SAMPLE CALCULATION:
Z PARAMETER:
(1) When O/P is open circuited i.e. I2 = 0
Z11 = V1/I1 , Z21 =V2 /I1.
(2) When I/P is open circuited i.e. II = 0
Z12 = V1/I2 , Z22 = V2 /I2.
Y PARAMETER:

(1) When O/P is short circuited i.e. V2 = 0


Y11 = I1/V1 Y21 = I2 /V1
(2) When I/P is short circuited i.e. VI = 0
Y12 = I1/V2 Y22 = I2 /V2.

ABCD PARAMETER:

(1)When O/P is open circuited i.e. I2 = 0


A = V1/V2 C = I1 /V2
(2)When O/P is short circuited i.e. V2 = 0
B = -V1/I2 D = -I1 /I2
H PARAMETER:

(1)When O/P is short circuited i.e. V2 = 0


h11 = V1/I1 h21 = I2 /I1
(2)When I/P is open circuited i.e. II = 0
h12 = V1/V2 h22 = I2 /V2

www.Vidyarthiplus.com

96

www.Vidyarthiplus.com

Y-Parameter
(1) Connect the circuit as shown in fig. & switch ON the experimental board.
(2) First short the O/P terminal & supply 5V to I/P terminal. Measure O/P & I/P current
(3) Secondly, short I/P terminal & supply 5V to O/P terminal. Measure I/P & O/P current using multi-meter.
(4) Calculate the values of Y parameter using Eq. (1) & (2).
(5) Switch off the supply after taking the readings.

ABCD Parameter
(1) Connect the circuit as shown in fig. & switch ON the experimental board.
(2) First open the O/P terminal & supply 5V to I/P terminal. Measure O/P voltage & I/P current
(3) Secondly, short the O/P terminal & supply 5V to I/P terminal. Measure I/P & O/P current using multi-meter.
(4) Calculate the A, B, C, & D parameters using the Eq. (1) & (2).
(5) Switch off the supply after taking the readings.

H Parameter
(1) Connect the circuit as shown in fig. & switch ON the experimental board.
(2) Short the output port and excite input port with a known voltage source Vs. So that V1 = Vs and V2 = 0. We
determine I1 and I2 to obtain h11 and h21.
(3) Input port is open circuited and output port is excited with the same voltage source Vs. So that V2 = VS and I1 =
0, we determine I2 and V1 to obtain h12 and h22.
(4) Switch off the supply after taking the readings.

RESULT:
Thus the various parameters of the two port network has been calculated and verified

www.Vidyarthiplus.com

97

www.Vidyarthiplus.com

Fig.1.Basic structure of CRO

Fig.2. Front Panel of CRO\

www.Vidyarthiplus.com

98

www.Vidyarthiplus.com
EXP. NO. 15
DATE:
STUDY OF CRO AND MEASUREMENT OF SINUSOIDAL VOLTAGE, FREQUENCY AND POWER
FACTOR
Objective
To introduce the basic structure of a cathode-ray Oscilloscope.
To get familiar with the use of different control switches of the device.
To visualize an ac signal, measure the amplitude and the frequency

Theory
Cathode-ray Oscilloscope

fluorescent screen (see Figure 1). When the cathode is heated (by Theory Cathode-ray Oscilloscope applying a small
potential difference across its terminals), it emits electrons. Having a potential difference between the cathode and the
anode (electrodes), accelerate the emitted electrons towards the anode, forming an electron beam, which passes to fall
on the screen. When the fast electron beam strikes the fluorescent screen, a bright visible spot is produced. The grid,
which is situated between the electrodes, controls the amount of electrons passing through it thereby controlling the
intensity of the electron beam. The X&Y-plates, are responsible for deflecting the electron beam horizontally and
vertically.

A sweep generator is connected to the X-plates, which moves the bright spot horizontally across the screen
and repeats that at a certain frequency as the source of the signal. The voltage to be studied is applied to the Y-plates.
The combined sweep and Y voltages produce a graph showing the variation of voltage with time, as shown in Fig. 2.

Alternating current (ac)


An ac signal can be of different forms: sinusoidal, square, or triangular. The sinusoidal is the most popular
type, which is the natural output of the rotary electricity generators. An ac voltage source can be represented by

(t ) m sin( wt )

(1)

where m is the maximum output voltage value, =2 ( is the frequency), and is the phase shift.
Table 1

www.Vidyarthiplus.com

99

www.Vidyarthiplus.com
Frequency (Hz)

Period (T)Sec

F(Hz)

Vp-p(V)

Vrms(V)

200
X
1000
Y
2000

Vrms(multimeter)=
Procedure
Part one
1. Turn on the Oscilloscope, wait a couple of seconds to warm up, then the trace will show up on the screen.
2. Adjust the intensity and the focus of the trace.
3. Use the X &Y-post. knobs to center the trace horizontally and vertically.
4. Connect a cable to Ch1 socket.
5. Turn on the Heath kit.
6. Connect the cable from Ch1 of the CRO to the SIN connector of the Heathkit, via a piece of wire.
7. A signal will appear on the screen.
8. Make sure that the inner red knobs of the Volt/Div and the Time/Div are locked clockwise.
9. Set the frequency of the generator to 200 Hz.
10. Adjust the Volt/Div and the Time/Div knobs so that you get a suitable size signal
(from 1-2 wavelengths filling most of the screen vertically).
11. Count the number of vertical squares lying within the signal, then calculate the peak
to peak value as:
Vp-p= No. vertical Div x Volt/Div
12. Calculate Vrms value, record in Table I:

www.Vidyarthiplus.com

100

www.Vidyarthiplus.com
Vrms= Vp-p / 2.sqr root(2)
13. Measure Vrms using the multimeter (connect the probes of the multimeter to the SIN
and the GND connectors).
14. Calculate the period T, record in Table I:
T = No. horizontal Div. Time/Div
15. Calculate the frequency, =1/T, record in the table.
16. Repeat steps 10-14 for the frequency values as in the table
Part two
1. Connect the cable from Ch1 to the upper connector of the line frequency of the Heathkit.
2. Adjust the Volt/Div and the Time/Div knobs so that you get a suitable size signal
(from 1-2 wavelengths filling most of the screen vertically).
3. Calculate the peak to peak voltage value.
4. Calculate Vrms value.
5. Measure Vrms using the multimeter.
6. Measure the period T, then calculate the frequency.
Vp-p=
Vrms=
Vrms(multimeter)=
T=
f=

Result