Вы находитесь на странице: 1из 10

B Vane Pumps(P15-24)_E.

03.11.20 1:18 PM

Page 15

VDR SERIES
VARIABLE VOLUME VANE PUMP

VDR13 Design Series


Variable Volume Vane Pump

R /min
20 to 45R
6MPa

The new design number 13 was created by modifying some of the components of old design numbers 11 and
12, and the new design installation compatible with the old design.

qE n e r g y e f f i c i e n t , e c o n o m i c a l
operation
wBuilt-in high-precision temperature compensation mechanism
eT h e r i n g i s d i s p l a c e d b y a
spring, and a rise in pressure
automatically moves it to the
center to make the discharge
rate zero.

rRelief valve and unloading valve


can be eliminated from the circuit.
tI t w a s p o s s i b l e t o r e d u c e t h e
size of the unit because there
was no increase of proportional
input to pressure which prevented increases in the temperature
of the fluid.

yNew design for lower noise and


improved durability

Specifications
Single Pump

Model No.

Capacity
c m3/rev

No-load Discharge Rate (r/min)


1000min 1

1200min 1

1500min 1

1800min 1

Allowable
Pressure
Peak Pressure
Adjustment Range
MPa
MPa{kgf/cm2}
{kgf/cm2}

Revolution Speed
min 1
Weight
kg
Min.
Max.

VDR-1A(B) -1A1-13
-1A2-1A3-

13.9
13.9
11.1

14
14
11

16.5
16.5
13.1

21
21
17

25
25
20

1 to 2 {10.2 to 20.6}
1.5 to 3.5 {15.3 to 35.7}
3 to 6 {30.6 to 61.2}

14
{143}

800

1800

VDR-2A(B) -1A1-13
-1A2-1A3-

25.1
25.1
22.2

25
25
22

30.1
30.1
26.5

38
38
34

45
45
40

1 to 2 {10.2 to 20.4}
1.5 to 3.5 {15.3 to 35.7}
3 to 6 {30.6 to 61.2}

14
{143}

800

1800

21

Double Pump
Model No.
Foot Mounting Type
(Flange Mounting Type)
VDR-11A(B)-1A1-1A1-13
VDR-11A(B)-1A1-1A2-13
VDR-11A(B)-1A1-1A3-13

Vent Side
Discharge
Rate
r/min

VDR-11A(B)-1A3-1A3-13

Pressure
Adjustment
Range
MPa{kgf/cm2}

Discharge
Rate
r/min

1 to 2
{10.2 to 20.4}

25

1.5 to 3.5
{15.3 to 35.7}

25
20

1.5 to 3.5 {15.3 to 35.7}


3 to 5 {30.6 to 51}

3 to 5 {30.6 to 51}

20

25

VDR-11A(B)-1A2-1A2-13
VDR-11A(B)-1A2-1A3-13
20

Shaft Side

20

Pressure Adjustment
Range
MPa{kgf/cm2}
1 to 2. {10.2 to 20.4}
1.5 to 3.5 {15.3 to 35.7}
3 to 5 {30.6 to 51}

to 5

{30.6 to 51}

Vent Side

Shaft Side

Allowable Peak
Pressure
MPa{kgf/cm2}

Revolution1Speed
min
Min.

Max.

800

1800

14
{143}
14
{143}

Weight
kg

A : 13.6
B : 13.9

14{143}

Note) 1. The discharge rate is the value at 1800min -1 no-load.


2. In addition to this model, the VDC Series (maximum working pressure: 14MPa) high-pressure variable vane pump is also available.
See page B-25 for more information.
3. The change from VDR-1 Series design number 11 to design number 12 represents a change in the shaft key width from 3.2mm to
4.76mm. This means that when using a 3.2mm key coupling, you need to use a stepped key (VD31J-302000) or add a new key
groove at 4.76.
4. There is no change in the mounting method with the change from the VDR-1 size design number 12 and VDR-2 design number 11 to
design number 13.

B-15

Vane Pumps

Features

B Vane Pumps(P15-24)_E.q

03.11.20 1:18 PM

Page 16

Understanding Model Numbers


Single Pump

Double Pump

VDR 1 A 1 A 2 13

VDR 1 1 A 1 A 1 1 A 2 13
Design number

Design number

Vane Pumps

Pressure adjustment range


1: 1 to 2MPa
2
{10.2 to 20.4kgf/cm }
2: 1.5 to 3.5MPa
2
{15.3 to 35.7kgf/cm }
3: 3 to 6MPa
{30.6 to 61.2kgf/cm2}

Shaft side pressure adjustment range


1: 1 to 2MPa
{10.2 to 20.4kgf/cm2}
2: 1.5 to 3.5MPa
{15.3 to 35.7kgf/cm2}
3: 3 to 5MPa
{30.6 to 51kgf/cm2}
Shaft side flow rate characteristics
A: Constant discharge rate type

Flow characteristics
A: Constant discharge type

Shaft side ring size 1

Ring size 1
Mounting method
A: Foot type mounting
B: Flange type mounting

Head side pressure adjustment range


Head side flow rate characteristics

Pump size 1, 2

Head side ring size 1

Pump Type: VDR Series


Variable Discharge Rate Vane Pump

Mounting method A: Foot type mounting


B: Flange type mounting
Shaft side pump size 1
Head side pump size 1
Pump Type: VDR Series
Variable Discharge Rate Vane Pump

Handling
zRotation Direction
The direction of rotation is always is
clockwise (rightward) when
viewed from the shaft side.
xDrain
Drain piping must be
direct piping up to a point that is
below the tank fluid level, and
back pressure due to pipe resistance should not exceed
0.03MPa.
cDischarge Volume Adjustment
The discharge flow rate is
decreased by clockwise (rightward) rotation of the discharge
rate adjusting screw, and
increased by counterclockwise
(leftward) rotation. Loosen the
lock nut before making adjustments. After adjustment is complete, re-tighten the lock nut. The
graph below provides general
guidelines for the relationship
between the rotation angle of the
flow rate adjusting screw and
the no-load discharge rate.

25

Pump capacity q cm /rev

30

However:
Q: No-load Discharge Rate Qr/min
q: Volume cm3/rev
N: Revolution Speed min-1
vPressure Adjustment
Pressure
is decreased by clockwise (rightward) rotation of the discharge
rate adjusting screw, and
increased by counterclockwise
(leftward) rotation.
bF a c t o r y D e f a u l t P - Q S e t t i n g s
(Standard Model)
Flow Rate Setting = Maximum
flow rate for model as indicated in the catalog
Pressure Setting = Pressure
shown in table to the right
nInitial Operation
Before operating the pump for the first time,
put the pump discharge side into
the no-load state and then
repeatedly start and stop the
motor to bleed all air from inside
the pump and the suction piping.
After confirming that the pump is
discharging oil, continue the noload operation for at least 10
minutes to discharge all the air
from the circuit.

20
15
10
8
5
4
0

B-16

45

90

135

180

225

270

Note) The values indicated above


are at maximum pump discharge volume with the flow
volume adjusting screw at
the 0position.
The broken line shows the
flow volume adjustment
range lower limit value.

Factory Default
Pressure Settings
MPa{kgf/cm2}
1 : 2.5{20.4}
2 : 3.5{35.7}
3 : 3.5{30.6}

Provide an air bleed valve in circuits where it is difficult to bleed


air before startup.
mSub Plate
When a sub plate
is required, specify a sub-plate
type from the table in the installation dimension diagram.
,For the hydraulic operating fluid,
use an R&O type and wearresistant type of ISO VG32 to 68
or equivalent (viscosity index of
at least 90). Use hydraulic operating fluid that provides kinematic viscosity during operation in
the range of 20 to 150mm2/s.
.The operating temperature range
is 15 to 60C. When the oil temperature at startup is 15C or
less, perform a warm-up operation at low pressure and low
speed until the oil temperature
reaches 15C. Use the pump in
an area where the temperature
is within the range of 0 to 60C.
0S u c t i o n p r e s s u r e i s - 0 . 0 3 t o
+0.03MPa (-0.3 to +0.3kgf/cm2 ),
and the suction port flow rate
should be to greater than
2m/sec.

B Vane Pumps(P15-24)_E.q

03.11.20 1:18 PM

Page 17

7T o ensure proper lubrication of


the pump's rubbing surfaces,
supply oil to the interior of the
pump before starting operation.
8W hen centering the pump shaft,
eccentricity with the motor shaft
should be no greater than 0.05mm.
Use a pump mounting base of sufficient rigidity. The angle error
should be no greater than 1.

matter, and watch out for discoloration. Whitish fluid indicates


that air has contaminated the
f l u i d , a n d b r o w n i s h f l u i d i n d icates the fluid is dirty.
4C ontact your agent about using
water- and glycol-based hydraulic
operating fluids.
5A t startup, repeat the inching
operation (start-stop) to bleed air
from the pump and pipes.
6E quip an air bleed valve in circuits where it is difficult to bleed
air before startup. See page C13 for more information.

Installation Dimension Drawings


VDR-1A-*-13 (Foot Mounting)
188.5
113

Flow rate adjusting screw

MVD-1-135Y-10

3.7

115 61.1 188

32

26

4.9

135 81.1 208

40

40

Pressure adjusting screw


M10 mounting bolt

10

16

B
MVD-1-135-10

Weight
H
kg

51

2 20

2 13
DR 2-Rc 1/4

59.5
60

210
178

C
MVD-1-115Y-10

25.5

53.90.1

120.6

h
Sub-plate

MVD-1-115-10

25

106

+0.024

4.76 +0.012

Sub Plate
Number

147.6
65

33

21.15 0.2
0

0.021

75.5

Motor Output
k W(4P)

1/2

3/8

3/4

1/2

1/2

3/8

3/4

1/2

0.75 to 1.5

2.2 to 3.7

VDR-1B-*-13 (Flange Mounting)

55

90
IN Rc 1/2

90
113
130

OUT 3/8

0
95.02 0.04

113
+0.024
4.76 +0.012

37

147.6
61

25

106

21.150.2
0
19.05 0.021

188.5
75.5

73

11 holes
Flow rate adjusting screw

4 16
59.5

Pressure adjusting screw


DR Rc 1/4

B-17

B
Vane Pumps

1A v o i d p u l l e y , g e a r , a n d o t h e r
drive systems that impart a radial or thrust load on the end of
the pump shaft. Mount the pump
so its pump shaft is oriented
horizontally.
2P rovide a suction strainer with a
filtering grade of about 100 m
(150 mesh). For the return line to
the tank, use a 25m line filter.
3M a n a g e h y d r a u l i c o p e r a t i n g
fluid so contamination is maintained at class NAS10 or lower.
Take care to avoid contamination with water and other foreign

B Vane Pumps(P15-24)_E.q

03.11.20 1:18 PM

Page 18

VDR-2A-*-13 (Foot Mounting)

212.1
90

278
170

54
27.7 0.1
0
25.4 0.021

+0.024

96.75

Vane Pumps

30

159

19

75 0.1

40

Flow rate adjusting screw


M12 mounting bolt

16

86.5

IN 2 to Rc Y

Pressure
adjusting
screw

OUT Rc 3/4
14

256
228
38 38

DR 2-Rc 1/4

Sub Plate
Number
MVD-2-135-10
MVD-2-160-10
MVD-2-160Z-10

Weight
kg

7.0 135 60
8.2 160 85

A
231.75
256.75

Motor Output
kW(4P)

33 29

2.2 to 3.7

48 48

5.5

1 1 /4

Applicable Pump
Model No.

VDR-2A-1A*-13

48
76

4 28x0.5 counterbore
13.5 holes

VDR-2B-*-13 (Flange Mounting)

278
108

170

42

+0.024

4 25x1 counterbore
13.5 holes

88.5
OUT Rc 3/4

DR Rc 1/4
IN Rc 1

B-18

212.1
102
20
16
50

140

0
0.021

40

25.4

27.7 0.1

Flow rate
adjusting screw

0
135 0.04

75

4.76 +0.012
96.75
171.75

4.76 +0.012

140

108

Pressure
adjusting
screw

B Vane Pumps(P15-24)_E.q

03.11.20 1:18 PM

Page 19

VDR-11A-*-13 (Foot Mounting)

+0.024

73

4.76 +0.012

32.5

65

77

25

25.5

208

53.9 0.1
14

25.5

135

120.6 0.35

20

25

2 to 43

81.1

M10 mounting bolt

77
38

OUT 3-Rc Z

8
42

IN 2-Rc 1

97.5

DR Rc 3/8

13 holes

Note) Sub plate is not include.


Contact your agent for more
information.

137

MVD-11-135-10

3/8

MVD-11-135X-10

1/2

Weight Applicable Pump Model


kg
No.
10.3

15

Sub Plate Number

185
158

DR Rc 3/8

VDR-11A-1A*-1A*-13

VDR-11B-*-*-13 (Flange Mounting)


4 21x0.5 counterbore
11 holes
222.1
113

IN 2-Rc 1/2

90
113
130

61

77

25
0
95.02 0.04

55

113
90

73

4.76

+0.024
+0.012

37

106

75.5

0
21.15 0.2
0
19.05 0.021

188.5
2-flow rate adjusting
screw

4 16
59.5
OUT 2-Rc 3/8

77

2-pressure
adjusting screw
DR 2-Rc 1/4

B-19

Vane Pumps

0
21.15 0.2
0
19.05 0.021

2-flow rate adjusting


screw

222.1

2-pressure adjusting
screw

113

106

188.5
75.5

B Vane Pumps(P15-24)_E.q

03.11.20 1:18 PM

Page 20

Performance Curves

Typical characteristics at hydraulic operating fluid kinematic viscosity of 32 mm2/s

1800min 1

VDR-1A-1A1-13

Lin

10

1.0
0.5

15
Lin
10

1.0

0.5

0.5
1
1.5
2
{5} {10.2}{15.7} {20.4}

10

2.0

Lin

1.0
0
1
2
3
4
5
6
7
{10.2}{20.4} {30.6} {40.8} {51} {61.2}{71.4}
2

VDR-2A-1A3-13

50

1.0

10

0.5

20

2.0

Lin

10

1.0

1
1.5
2
{10.2} {15.7} {20.4}

3.0

30

0.5 1
1.5
2
2.5 3.0 3.5
{5} {10.2}{15.7}{20.4}{25.4}{30.6}{35.7}

40
30
20

5.0
4.0
3.0
2.0
1.0
0
1
2
3
4
5
6
7
{10.2}{20.4} {30.6}{40.8} {51} {61.2}{71.4}
Lin

10
0

Discharge pressure P MPa{kgf/cm }

Discharge pressure P MPa{kgf/cm }

Discharge pressure P MPa{kgf/cm }

Use the formula below to calculate a pump's required drive force.


PQ
H =
60

H
+L P
Q
L

:
:
:
:

Input kW
Pressure MPa
Flow rate r/min
Power loss kW

Power Loss Curve


VDR-1

2.0

1.5

1.0
1

min

1800

0.5

min

1500

1
{10.2}

VDR-2

2.5

Power loss at full cutoff kW

Power loss at full cutoff kW

2.5

2
3
{20.4} {30.6}

4
{40.8}

5
{51}

6
{61.2}

2.0

1.5
1

1.0

180

0m

in

in

0m

150

0.5

7
{71.4}

Discharge pressure P MPa{kgf/cm2}

1
{10.2}

2
3
{20.4} {30.6}

4
{40.8}

5
{51}

6
{61.2}

7
{71.4}

Discharge pressure P MPa{kgf/cm2}

Noise Characteristics

1800min1

1500min1

60

1
{10.2}

2
{20.4}

3
{30.6}

4
{40.8}

5
{51}

6
{61.2}

Discharge pressure P MPa{kgf/cm2}

B-20

7
{71.4}

Measurement Position:
1 meter behind pump

VDR-2

80

Noise level dB(A)

Noise level dB(A)

70

50

Measurement Position:
1 meter behind pump

VDR-1

80

1800min1

70

1500min1
60

50

1
{10.2}

2
{20.4}

3
{30.6}

4
{40.8}

5
{51}

6
{61.2}

Discharge pressure P MPa{kgf/cm2}

7
{71.4}

Input Lin kW

Lin

40

Discharge rate Q /min

1.5

30

Discharge rate Q /min

Input Lin kW

Discharge rate Q /min

3.0

Discharge pressure P MPa{kgf/cm }

VDR-2A-1A2-13

50

40

0.5
{5}

15

Discharge pressure P MPa{kgf/cm }

VDR-2A-1A1-13

0
0.5 1 1.5 2.0 2.5 3 3.5
{5}{10.2}{15.3}{20.4}{25.4}{30.6}{35.7}

20

20

Discharge pressure P MPa{kgf/cm }


50

1.5

Input Lin kW

20

Input Lin kW

1.5

25

Discharge rate Q /min

15

VDR-1A-1A3-13

25

Input Lin kW

20

Discharge rate Q /min

25

Input Lin kW

Vane Pumps

Discharge rate Q /min

VDR-1A-1A2-13

B Vane Pumps(P15-24)_E.q

03.11.20 1:18 PM

Page 21

Cross-sectional Drawing
VDR-1A-*-13
VDR-2A-*-13

40 33 20 26 38 15 3 11 21 39 18 13 22 16 12 36

41 37 14 2 35 10

9 28 29 30 19

B
Vane Pumps

4 25 23 17 6

OUTLET
INLET
7 8 32 1 31 34 24

27 5

List of Sealing Parts


Part
No.

Applicable Pump Model No.

VDR-1A-*-13

VDR-2A-*-13

Seal Kit Number

VDAS-101A00

VDAS-102A00

Part Name

Part Number

Q'ty

20

Packing

VD32J-101000

21

Square ring

VD33J-101000

29

Oil seal

ISRD-204010

31

O-ring

32

Part Number

Part No.

Q'ty

VD32J-102000

1A-G45

ISP-284811

1A-P20

1A-G30

O-ring

1A-P10A

1A-P12

33

O-ring

1A-P12

1A-P14

34

O-ring

1A-P5

1A-P9

35

O-ring

1A-G70

1A-G100

Note) 1. Oil seals are manufactured by Nippon Oil Seal Industry


Co. Ltd. (NOK).
2. O-ring 1A-** refers to JIS B2401-1A-**.
3. For VDR-*B-*-13, the seal kit number becomes VDBS10*B00, without the 31 and 32 O-rings.

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Part Name

Part No.

Body
Cover
Cover
Cover
Shaft
Piston
Ring
Vane
Plate (S)
Plate (H)
Plate
Holder
Holder
Shim

15
16
17
18
19
20
21
22
23
24
25
26
27
28

Part Name
Shim
Retainer
Spring
Spring
Key
Packing
Square ring (O-ring)
Needle
Screw
Screw
Nut
Pin
Pin
Bearing

Part No.

Part Name

29
30
31
32
33
34
35
36
37
38
39
40
41

Oil seal
Snap ring
O-ring
O-ring
O-ring
O-ring
O-ring
Nut
Screw
Screw
Screw
Screw
Nameplate

VDR-11A-*-13
39 24 31 20 19 46 17 4 13 25 45 21 15 26 18 14 30

OUTLET
7 9 10 38

44 5 29 27

47 42 16 3

8 23 2 41

INLET
37 40 28 36

12

11 1 33 43 34 35 22

32 6

List of Sealing Parts


Applicable Pump Model No.

Part
No.

Seal Kit Number


Part Name

VDR-11A-*-*-13
VDAS-111A00
Part Number

Q'ty

24

Packing

VD32J-101000

25

Square ring

VD33J-101000

34

Oil seal

ISRD-204010

37

O-ring

1A-P20

38

O-ring

1A-P10A

39

O-ring

1A-P12

40

O-ring

1A-P5

41

O-ring

1A-G70

Part No. Part Name


1
2
3
4
5
6
7
8
9
10

Body
Body
Cover
Cover
Cover
Shaft
Piston
Rotor
Ring
Vane

Part No.
11
12
13
14
15
16
17
18
19
20

Part Name
Plate (S)
Plate (H)
Plate
Holder
Holder
Shim
Shim
Retainer
Spring
Spring

Note) 1. Oil seals are manufactured by Nippon Oil Seal Industry Co. Ltd. (NOK).
2. O-ring 1A-** refers to JIS B2401-1A-**.
3. For VDR-11B-*-*-13, the seal kit number becomes VDBS-111B00, without the
37 and 38 O-rings.

Part No.

Part Name

21
22
23
24
25
26
27
28
29
30

Spring
Key
Key
Packing
Square ring
Needle
Screw
Screw
Nut
Pin

Part No.

Part Name

31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

Pin
Pin
Bearing
Oil seal
Snap ring
Nut
O-ring
O-ring
O-ring
O-ring
O-ring
Screw
Screw
Screw
Screw
Screw
Nameplate

B-21

B Vane Pumps(P15-24)_E.q

03.11.20 1:18 PM

Page 22

Uni-pump Specifications
Understanding Model Numbers

UVD 1 A A 2 1.5 4 16

UVD 11 A A

4 16

Design number

Design number
Number of motor poles: 4 (P)

Number of motor poles: 4 (P)

Motor output (kW)


1.5, 2.2, 3.7

Vane Pumps

Motor output (kW)


0.75, 1.5, 2.2, 3.7

Shaft side pump pressure adjustment range


1: 1.0 to 2.0MPa
{10.2 to 20.4kgf/cm2}
2: 1.5 to 3.5MPa
{15.3 to 35.7kgf/cm2}
3: 3.0 to 5.0MPa
{30.6 to 51kgf/cm2}
Shaft side pump flow rate characteristics
A: Constant discharge type
Head side pump pressure adjustment range:
Same as the shaft side pump
Head side pump flow rate characteristics
A: Constant discharge type
A: Foot type mounting

Pressure adjustment range


1: 1.0 to 2.0MPa
2
{10.2 to 20.4kgf/cm }
2: 1.5 to 3.5MPa
2
{15.3 to 35.7kgf/cm }
3: 3.0 to 6.0MPa
2
{20.4 to 61.2kgf/cm }
Flow characteristics
A: Constant discharge type
A: Foot type mounting
Pump size 1: VDR-1B
2: VDR-2B
Pump Type: VDR (13D) Series Uni-pump

Pump size 11: VDR-11B


Pump Type: VDR (13D) Series Uni-pump

Specifications
Model No.

Maximum Working
Pressure
MPa{kgf/cm2}

UVD-11A
UVD-12A
UVD-11A

Maximum Flow Rate r/min

6{61.2}
5{51.0}
5{51.0}

50Hz

60Hz

21
38
21-21

25
45
25-25

Motor Selection Curves

60Hz 50Hz
areas areas

Discharge rate Q /min

UVD-2A
UVD-1A

UVD-1A

UVD-2A

40

3.7kW

30

20
2.2kW
0.75kW
10

1.5kW

{10.2}

{20.4}

{30.6}

{40.8}

{51.0}

{61.2}

Discharge pressure P MPa{kgf/cm2}

B-22

Selecting a motor
The area under a motor output
curve in the graph to the left is the
operating range for that motor
under the rated output for that
motor.
Example:
To find the motor that can produce
p r e s s u r e o f 3 . 5 M P a a n d a d i scharge rate of 21r/min.
Selection Process
Since the intersection of the two
broken lines from a pressure of
3.5MPa and discharge rate of
2 1r / m i n i n t e r s e c t i n t h e a r e a
under the 2.2kW curve, it means
that a 2.2kW motor should be
used. In the case of a double
pump configuration, select a
motor that is larger than the total
power required by both pumps.

B Vane Pumps(P15-24)_E.q

03.11.20 1:18 PM

Page 23

Installation Dimension Drawings


UVD-1A

108.6

D
KL
130 (IN-OUT Port dimension)
113

75.5
Q

Terminal Rc 1/2 (IN)


box
Rc 3/8
B terminal (OUT on opposite side)

61
22.5
16

IL

A
P

P
O

Rating
plate

Hangers
x2

106
55

V
H
G
0
C 0.5

50
Pressure
adjusting
screw

KD

Vane Pumps

Flow rate
adjusting screw

(Round drain hole)


Rc 1/4 (DR)
J
E

Auxiliary View R (4 locations)


Motor Dimensions mm

Output

Uni-pump
A

IL

ST

KD

KL

124

105

80

160

62.5

50

10

160

34

229

155

135

10 25

22

126

21

16.5

80M

0.75

20

142.5 118.5

90

178

70

62.5

10

179

35

261

170

155

10 16

22

136

36.5

45

55

18

90L

1.5

24

160.5

100

195

80

70

13

197.5

45

293.5

195

175

12 25

22

150

45.5

50

55

22

100L

2.2

28

UVD-1A-A1-0.75-4-16
UVD-1A-A2-0.75-4-16
UVD-1A-A2-1.5-4-16
UVD-1A-A3-1.5-4-16
UVD-1A-A3-2.2-4-16

Frame
Weight
kW
No. (4poles) kg

133

UVD-2A
D
150 (IN-OUT port dimension)
170
108
Q
Q

IL

42.5

P
Hangers
x2

0
C 0.5

Rc 1 (IN)
Rc 3/4
(OUT on opposite side)
Rc 1/4 (DR)
T

P
O

140

66

75

KD
(Round
drain hole)

L
98
16

Pressure
adjusting
screw

166.1

Flow rate
adjusting screw

KL

F
N

42.5

R
Auxiliary View R: Oval Hole Detail
(4 locations)
Motor Dimensions mm

Output

Uni-pump
C

ST

KD

KL

142.5 118.5

90

178

70

62.5

10

179.0

35

261

170

155

10 16

22

136

36.5

45

55

18

90L

1.5

37

160.5

133

100

195

80

70

13

197.5

45

293.5

195

175

12 25

22

150

45.5

50

55

22

100L

2.2

41

171

140

112

219

95

70

14

221.5

45

311

224

175

12 25

22

161

53

55

66

22

112M

3.7

50

IL

UVD-2A-A1-1.5-4-16
UVD-2A-A2-1.5-4-16
UVD-2A-A2-2.2-4-16
UVD-2A-A3-2.2-4-16
UVD-2A-A2-3.7-4-16
UVD-2A-A3-3.7-4-16

Frame
Weight
kW
No. (4poles) kg

B-23

B Vane Pumps(P15-24)_E.q

03.11.20 1:18 PM

Page 24

UVD-11A
185.6
138
99.5

D
KL
130 (IN-OUT port dimension)
113

A
P

61
22.5
16

75.5
Q

L
IL
P
O

Hangers
x2

106
55

V
0

Pressure
adjusting
screw

C 0.5

50

KD

2-Rc 1/2 (IN)


2-Rc 3/8
(OUT on opposite side)
2-Rc 1/4 (DR)

(Round drain hole)


J
E

Vane Pumps

Flow rate
adjusting screw

Auxiliary View R (4 locations)

Motor Dimensions mm

Output

Uni-pump

Frame
Weight
kW
No. (4poles) kg

ST

KD

KL

142.5 118.5

90

178

70

62.5

10

179

35

261

170

155

10 16

22

136

36.5

45

55

18

90L

1.5

30

160.5

133

100

195

80

70

13

197.5

45

293.5

195

175

12 25

22

150

45.5

50

55

22

100L

2.2

34

171

140

112

219

95

70

14

221.5

45

311

224

175

12 25

22

161

53

55

66

22

112M

3.7

43

IL

UVD-11A-A1-A1-1.5-4-16
UVD-11A-A1-A2-1.5-4-16
UVD-11A-A1-A3-1.5-4-16
UVD-11A-A2-A2-1.5-4-16
UVD-11A-A2-A3-1.5-4-16
UVD-11A-A3-A3-1.5-4-16
UVD-11A-A1-A2-2.2-4-16
UVD-11A-A1-A3-2.2-4-16
UVD-11A-A2-A2-2.2-4-16
UVD-11A-A2-A3-2.2-4-16
UVD-11A-A3-A3-2.2-4-16
UVD-11A-A1-A3-3.7-4-16
UVD-11A-A2-A2-3.7-4-16
UVD-11A-A2-A3-3.7-4-16
UVD-11A-A3-A3-3.7-4-16

B-24

Вам также может понравиться