ROOF SOLUTIONS
TRUS JOIST
TJI 110 TJI 210
TJI 230 TJI 360
TJI 560 JOISTS
www.iLevel.com
1.888.iLevel8 (1.888.453.8358)
All In One
WELCOME TO iLEVEL
February 2008
91 2 "
1178"
14"
16"
TJI
Joist
Weight
(lbs/ft)
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
2.3
2.6
2.7
2.5
2.8
3.0
3.0
4.0
2.8
3.1
3.3
3.3
4.2
3.3
3.5
3.5
4.5
Basic Properties
Maximum
Joist Only
Resistive
El x 10 6
Moment (1)
(in. 2-lbs)
(ft-lbs)
2,380
2,860
3,175
3,015
3,620
4,015
6,180
9,500
3,565
4,280
4,755
7,335
11,275
4,895
5,440
8,405
12,925
140
167
183
238
283
310
419
636
351
415
454
612
926
566
618
830
1,252
Maximum
Vertical
Shear
(lbs)
1,220
1,330
1,330
1,560
1,655
1,655
1,705
2,050
1,860
1,945
1,945
1,955
2,390
2,190
2,190
2,190
2,710
Material Weights
Reaction Properties
31 2" Intermediate
13 4"
Reaction (lbs)
End
Reaction
No Web
With Web
(lbs)
S tiffeners Stiffeners
885
1,935
N.A.
980
2,145
N.A.
1,035
2,410
N.A.
885
1,935
2,295
980
2,145
2,505
1,035
2,410
2,765
1,080
2,460
2,815
1,265
3,000
3,475
885
1,935
2,295
980
2,145
2,505
1,035
2,410
2,765
1,080
2,460
2,815
1,265
3,000
3,475
980
2,145
2,505
1,035
2,410
2,765
1,080
2,460
2,815
1,265
3,000
3,475
(1) Caution: Do not increase joist moment design properties by a repetitive member use factor.
Floor Panels
Southern Pine
1 2"
plywood. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7
5 8"
3 4"
5 8"
3 4"
7 8"
Roofing
Asphalt shingles . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 psf
Wood shingles. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0 psf
Clay tile. . . . . . . . . . . . . . . . . . . . . . . . . . . 9.0 to 14.0 psf
Slate (3 8" thick). . . . . . . . . . . . . . . . . . . . . . . . . . 15.0 psf
Roll or Batt Insulation (1" thick):
Floor Finishes
Hardwood (nominal 1") . . . . . . . . . . . . . . . . . . . . . 4.0 psf
General Notes
Design reaction includes all loads on the joist. Design shear is computed at the inside face of supports
and includes all loads on the span(s). Allowable shear may sometimes be increased at interior supports in
accordance with ICC ES ESR-1153, and these increases are reflected in span tables.
The following formulas approximate the uniform load deflection of (inches):
For
TJI 110, 210, 230, and 360 Joists
4
2
= 22.5 wL + 2.67 wL5
El
d x 10
w =
L =
d =
El =
For
TJI 560 Joists
4
2
= 22.5 wL + 2.29 wL5
El
d x 10
Concrete:
Regular (1"). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.0 psf
Lightweight (1"). . . . . . . . . . . . . . . . . . . . . 8.0 to 10.0 psf
Gypsum concrete (3 4"). . . . . . . . . . . . . . . . . . . . . . 6.5 psf
Ceilings
Acoustical fiber tile. . . . . . . . . . . . . . . . . . . . . . . . 1.0 psf
1 2"
5 8"
February 2008
134"
11/4"138"
38"
117 8"
912"
1178"
14"
14"
2116"
912"
1178"
14"
16"
Depth
91 2"
117 8"
2516"
14"
11/4"138"
912"
38"
1178"
14"
16"
16"
2516"
110
210
230
360
560
138"
1178"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
1178"
14"
16"
Long-term deflection under dead load, which includes the effect of creep, has not been considered. Bold italic spans reflect initial dead
load deflection exceeding 0.33".
General Notes
(1) Web stiffeners are required at intermediate supports of continuous-span joists when the intermediate bearing length is less than 514"
and the span on either side of the intermediate bearing is greater than the following spans:
TJI
38"
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
11/4"138"
38"
TJI
February 2008
91 2"
117 8"
14"
16"
TJI
Live
Load
L /480
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
10'
Total
Load
Live
Load
L /480
190
210
236
190
210
236
241
294
190
210
236
241
294
210
236
241
294
127
147
159
*
*
*
*
*
*
*
*
*
*
*
*
*
*
12'
14'
Total
Load
Live
Load
L /480
Total
Load
Live
Load
L /480
152
169
190
152
169
190
193
236
152
169
190
193
236
169
190
193
236
77
90
98
*
*
*
*
*
*
*
*
*
*
*
*
*
*
127
141
158
127
141
158
162
197
127
141
158
162
197
141
158
162
197
50
59
64
83
97
105
136
*
*
*
*
*
*
*
*
*
*
40
44
57
67
73
95
138
83
96
104
*
*
*
*
*
*
81
88
92
106
119
121
148
95
106
119
121
148
106
119
121
148
48
52
69
101
59
69
75
98
*
93
100
*
*
87
97
108
132
85
94
106
108
132
94
106
108
132
20'
Live
Load Total
L /480 Load
22'
Live
Load Total
L /480 Load
39
51
76
78
97
119
39
58
78
108
51
56
73
107
69
75
*
*
84
93
97
119
85
95
97
119
43
56
83
53
57
75
*
77
88
108
77
87
88
108
24'
Live
Load Total
L/480 Load
45
91
44
65
81
99
59
86
81
99
General Notes
1. Calculate actual total and live load in pounds per linear foot (plf).
If a live load deflection limit of L /360 is desired, multiply value in Live Load
column by 1.33. The resulting live load shall not exceed the Total Load shown.
20
25
12"
16"
19.2"
24"
20
27
32
40
25
34
40
50
55
60
55
74
88
110
60
80
96
120
WARNING
DO NOT walk on joists until braced.
INJURY MAY RESULT.
Joists are
unstable
until braced
laterally
Bracing Includes:
Blocking
Hangers
Rim Board
Sheathing
Rim Joist
Strut Lines
WARNING NOTES:
1. All blocking, hangers, rim boards, and rim joists at the end supports of the TJI
joists must be c ompletely installed and properly nailed.
2. Lateral strength, like a braced end wall or an existing deck, must be established at
the ends of the bay. This can also be accomplished by a temporary or permanent
deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.
3. Safety bracing of 1x4 ( minimum) must be nailed to a braced end wall or sheathed
area (as in note 2) and to each joist. Without this bracing, buckling sideways or
rollover is highly probable under light c onstruction loadssuch as a worker or one
layer of unnailed sheathing.
4. Sheathing must be completely attached to each TJI joist before additional loads
can be placed on the system.
5. Ends of cantilevers require safety bracing on both the top and b ottom flanges.
6. The flanges must remain straight within a tolerance of 12" from true alignment.
February 2008
Works
as part of iLevel Trus Joist
TJ-Beam and TJ-Xpert software
Customer Satisfaction
84%
96% 99.9%
63%
28%
Better
Excellent
Blocking
February 2008
For projects that demand quality, performance, and customer satisfaction, upgrade to the iLevel TJ-Pro Rated Floor System.
Contact your iLevel representative or call 1-888-453-8358 for more information.
112" knockouts
at approximately
12" on-center
WARNING
Joists are unstable until
laterally braced.
See Warning Notes on page 5.
Gap:
18" minimum
234" maximum
Three 8d (0.113" x 212") nails,
clinched
Web stiffener(1) each side
TJI 110 joists:
58" x 2516" minimum
TJI 210 joists:
34" x 2516" minimum
TJI 230 and 360 joists:
78" x 2516" minimum
Tight
1"
134" minimum
bearing
112"
TJI 560
floor joist
Gap:
18" minimum
234" maximum
Three 16d (0.135"
x 312") nails
112"
2x4 web
stiffener(2)
Tight
TJI 560
rim joist
February 2008
floor details
Intermediate Bearing
No Load Bearing Wall Above
2x4 minimum
squash blocks
Blocking
panel
116"
B1
B1
W
B2
B3
B3
W
Apply subfloor
adhesive to all
contact surfaces
Top flange
hanger
Face mount
hanger
H1
H3
TJI
Backer block
both sides of
web with single
TJI joist
110
912" or 14"
117 8"
Filler Block(1)
(Detail H2)
2x6
2x8
Cantilever
Filler
(Detail E4)
2x6
4'-0"
long
2x10
6'-0"
long
2x6 + 38"
sheathing
4'-0" long
Depth
210
912" or
117 8"
2x6 + 38"
sheathing
Backer Block(1)
(Detail F1
or H2)
5 8"
or 34"
34"
14" or
16"
2x8 + 38"
sheathing
230 or 360
912" or
14" or
117 8"
16"
2x6 + 12" 2x8 + 12"
sheathing sheathing
2x10 + 38"
sheathing
6'-0" long
2x6 + 12"
sheathing
4'-0" long
or 7 8"
2x10 + 12"
sheathing
6'-0" long
1" net
560
14" or
16"
Two
Two
2x6
2x8
117 8"
Not applicable
2x6
2x8
(1) If necessary, increase filler and backer block height for face mount hangers and maintain 18" gap at top of joist.
See detail W. Filler and backer block dimensions should accommodate required nailing without splitting. The
suggested minimum length is 24" for filler and 12" for backer blocks.
2x4 minimum
squash blocks
116"
4"(3)
4"(3)
4"(3)
6"
6"
6"
Equivalent
Nominal
Framing Width
Maximum
Capacity
(plf)
2"
3"
3"
425
480
720
(1) One row of fasteners permitted (two at abutting panel edges) for diaphragms. Stagger nails when using
4" oncenter spacing and maintain 38" joist and panel edge distance. For other applications, multiple rows of fasteners are
permitted if the rows are offset at least 12" and staggered.
(2) To achieve code-tabulated, unblocked diaphragm design values for TJI 110, 210, and 230 joists, use fasteners in combination with an ASTM D3498 non-polyurethane sub-floor adhesive. For nailed-only conditions, use 85% of code-tabulated values.
(3) Can be reduced to 3" on-center for light gauge steel straps with 10d (0.148" x 11/2") nails.
CS
February 2008
Rim board is often an important structural link in the ability of a home to resist lateral wind loads. It also transfers
vertical load around the TJI joists.
Rim board detail A3 (shown below) satisfies conventional construction requirements. But if your project requires a
designed solution, see our iLevel Rim Board Specifiers Guide for Lateral Wind Loads. This easytouse guide for
specifiers and code officials goes beyond conventional construction guidelineswhich were based on the smaller,
simpler homes of the pastand p rovides design information that considers todays larger, more complex homes.
Plate nail
Floor panel nail
A1
When sheathing thickness
exceeds 78", trim sheathing
tongue at rim board
Toe
nail
A3. A3.
A3 A3.
1
2
3
2x_ stud wall at
16" on-center
A2
Flashing
A3.
4
lag bolt
lag bolt
4"
6"(1)
If more than one row of nails is used, the rows must be offset at least 1/2" and staggered.
14 ga. staples may be substituted for 8d (0.113" x 21/2") nails if minimum penetration of 1" is achieved.
Specifications
Rim Board Thickness
Plate Nail16d (0.135" x 312")
Floor Panel Nail8d (0.131" x 212")
Toe Nail10d (0.128" x 3")
Wall Sheathing
applications.
A3
Conventional Construction,
Code Minimum
11 8" or 114"
16" o.c.
6" o.c.
6" o.c.
Per code
10
6"
16"
LA
(1) Can be reduced to 4" on-center with maximum nail penetration of 138" into the narrow edge.
12"
min.
3 8"
Nail Size
1 2"
Toe nail
Treated
2x_ ledger
Fastener
Plate nail
Floor panel nail
February 2008
ALLOWABLE HOLES
Minimum distance from Table B
6"
6"
2 x D1
D1
minimum
(applies to all holes
except knockouts)
L2
L1
2 x L2 D2
minimum
6"
6"
Minimum distance from edge of hole to inside face of nearest end support
Depth
9 1 2 "
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
2"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
3"
1'-6"
1'-6"
2'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
4"
2'-0"
2'-0"
2'-6"
1'-0"
1'-0"
1'-0"
1'-6"
1'-6"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
87 8"
5'-0"
5'-6"
6'-0"
7'-0"
8'-0"
2'-6"
3'-0"
3'-6"
5'-6"
6'-0"
1'-6"
2'-0"
3'-0"
3'-0"
11"
5'-0"
6'-0"
6'-6"
8'-0"
9'-0"
3'-6"
4'-0"
6'-0"
6'-6"
13"
6'-0"
6'-6"
9'-0"
10'-0"
2"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
3"
1'-6"
2'-0"
2'-0"
1'-0"
1'-0"
1'-0"
1'-0"
2'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
4"
2'-6"
2'-6"
3'-0"
1'-6"
2'-0"
2'-0"
2'-6"
3'-6"
1'-0"
1'-0"
1'-0"
1'-0"
1'-6"
1'-0"
1'-0"
1'-0"
1'-0"
5"
3'-6"
4'-0"
4'-6"
2'-6"
3'-0"
3'-0"
4'-0"
5'-0"
1'-6"
2'-0"
2'-0"
2'-6"
3'-6"
1'-0"
1'-0"
1'-0"
1'-6"
6 1 2 "
4'-6"
5'-0"
5'-0"
4'-6"
5'-0"
5'-6"
6'-6"
7'-0"
3'-6"
4'-0"
4'-0"
5'-6"
6'-6"
2'-6"
3'-0"
4'-0"
5'-0"
7"
87 8"
11"
13"
4'-6"
5'-6"
5'-6"
6'-6"
7'-6"
4'-0"
4'-6"
5'-0"
6'-6"
7'-0"
3'-6"
3'-6"
5'-0"
6'-0"
6'-0"
6'-6"
7'-0"
7'-6"
8'-0"
6'-0"
6'-6"
7'-0"
8'-0"
9'-0"
6'-6"
7'-0"
9'-0"
10'-0"
8'-0"
8'-6"
9'-0"
9'-6"
10'-0"
8'-0"
9'-0"
10'-0"
11'-0"
10'-6"
11'-0"
11'-6"
12'-0"
Minimum distance from edge of hole to inside face of nearest intermediate or cantilever support
Depth
9 1 2 "
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
2"
1'-6"
2'-0"
2'-6"
1'-0"
1'-0"
1'-0"
2'-0"
1'-6"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
3"
2'-6"
2'-6"
3'-0"
1'-0"
1'-0"
2'-0"
3'-0"
3'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
4"
3'-0"
3'-6"
4'-0"
1'-6"
2'-0"
2'-6"
4'-0"
4'-6"
1'-0"
1'-0"
1'-0"
2'-0"
1'-6"
1'-0"
1'-0"
1'-0"
1'-0"
87 8"
8'-0"
9'-0"
9'-6"
11'-0"
12'-0"
4'-6"
5'-0"
5'-6"
8'-6"
9'-6"
3'-0"
4'-0"
6'-6"
7'-0"
11"
8'-0"
9'-0"
10'-0"
12'-6"
13'-6"
5'-6"
6'-6"
10'-0"
11'-0"
13"
9'-6"
10'-6"
13'-6"
15'-0"
2"
1'-6"
2'-0"
2'-6"
1'-0"
1'-0"
1'-0"
2'-0"
3'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
3"
2'-6"
3'-0"
3'-0"
1'-6"
2'-0"
2'-6"
3'-6"
4'-6"
1'-0"
1'-0"
1'-0"
2'-0"
3'-0"
1'-0"
1'-0"
1'-0"
1'-0"
4"
3'-6"
4'-0"
4'-6"
2'-6"
3'-0"
3'-6"
5'-0"
6'-0"
1'-0"
2'-0"
2'-6"
4'-0"
5'-0"
1'-0"
1'-0"
2'-0"
3'-6"
5"
5'-6"
6'-0"
6'-6"
4'-0"
4'-6"
5'-0"
7'-0"
8'-0"
2'-6"
3'-6"
4'-0"
5'-6"
7'-0"
2'-0"
2'-6"
4'-0"
5'-6"
6 1 2 "
6'-6"
7'-0"
7'-6"
6'-6"
7'-6"
8'-0"
9'-6"
10'-6"
5'-0"
6'-0"
6'-0"
9'-0"
10'-0"
4'-6"
5'-0"
7'-6"
9'-0"
7"
87 8"
11"
13"
7'-0"
8'-0"
8'-6"
9'-6"
11'-0"
6'-0"
7'-0"
7'-6"
10'-0"
11'-0"
5'-6"
6'-0"
8'-6"
10'-0"
9'-0"
10'-0"
10'-0"
11'-0"
12'-0"
9'-0"
10'-0"
10'-6"
12'-0"
13'-6"
9'-6"
10'-6"
13'-0"
14'-6"
12'-0"
12'-6"
13'-0"
14'-0"
15'-0"
12'-6"
13'-0"
14'-6"
16'-0"
15'-6"
16'-0"
17'-0"
18'-0"
DO NOT
cut or notch flange.
General Notes
4. Maintain the required minimum distance from the end and the
intermediate or cantilever support.
DO NOT
cut holes in cantilever
reinforcement.
February 2008
11
cantilevers
Cantilevers Less Than 5" (Brick Ledge)
2'-0"
2'-0"
L1
Less than 5"
L1
5" to 24"
12" length of
reinforcement on
one side at E5/E7, both sides at
E6/E8. Attach to joist with one 8d
(0.131" x 212") nail at each corner.
34"
5"
Web stiffeners
required at E1W
4"
to 2
11 2
Blocking panel between each
joist. Full depth vertical
blocking at E5 and E6,
horizontal blocking at E7
and E8.
Wood
backer
Nail with connections
equivalent to floor panel
schedule (E7 and E8)
s
ime
til
can
th
eng
rl
eve
gth
len m
r
e
v
u
tile xim nly)
Can 0" ma ads o
o
l
4' orm
if
(un
6'-0" length of TJI joist reinforcement and filler block at E4. Attach to joist
web with three rows 10d (0.148" x 3") nails at 6" on-center, clinched. Use 4'-0"
length with 912" and 1178" TJI joists, and attach to joist web with two rows 10d
(0.148" x 3") nails at 6" on-center, clinched. Not for use with TJI 560 joists.
Less
than 5"
12
February 2008
cantilevers
Cantilever Reinforcement
Section A: Cantilevers less than 5" (Brick Ledge)
Depth
9 1 2 "
117 8"
14"
9 1 2 "
117 8"
14"
16"
9 1 2 "
117 8"
14"
16"
117 8"
14"
16"
117 8"
14"
16"
TJI
110
210
230
360
560
Roof
Truss
Span
35 PSF
16"
19.2"
E5
E5
E5
E5
E5
E5
X
20'
22'
24'
26'
28'
30'
32'
20'
22'
24'
26'
28'
30'
32'
24'
26'
28'
30'
32'
34'
28'
30'
32'
34'
36'
38'
40'
30'
32'
34'
36'
38'
40'
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
TJI
55 PSF
19.2"
E5
E5
E5
E5
E5
E5
X
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
E5
35 PSF
24"
E5
E5
E5
E6
X
X
X
E5
E5
E5
E5
E6
E6
X
E5
E5
E5
E5
X
X
E5
E5
E5
E6
E6
E6
E6
E5
E5
E5
E6
E6
E6
16"
E2
19.2"
E2
E3
X
E2
E2
E3
E2
E3
X
E2
E3
X
E2
E3
E2
E3
X
E2
E3
E2
E2
E3
X
E2
E2
X
X
X
X
E2
E2
E3
X
X
X
E1W
E1W
E2
E2
E2
E2
E2
E1W
E1W
E1W
E1W
55 PSF
19.2"
X
X
X
X
X
X
E2
E3
X
E2
X
X
X
E2
E2
E3
X
E2
E3
X
X
X
E1W
E2
E2
E2
24"
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
E2
E2
E2
E3
E3
E3
E3
E2
E2
E2
E2
General Notes
2. Locate the Roof Truss Span (horizontal) that meets or exceeds your c ondition.
3. Identify the cantilever condition (less than 5" or 5" to 24") and locate the Roof
Total Load and On-Center Joist Spacing for your a pplication.
4. Scan down to find the appropriate cantilever detail and refer to drawing
on page 12:
Blank cells indicate that no reinforcement is required.
E4 may be used in place of E2 or E3 except when using TJI 560 joists.
X indicates that cantilever will not work. Use TJBeam or TJ-Xpert software,
or reduce spacing of joists and recheck table.
February 2008
13
Fire-safe construction
Fire-safe construction and life safety are major concerns for everyone in the building materials and
construction industry. The 2005 US Fire Administration (http://www.usfa.dhs.gov/statistics/national/) statistics
on residential and commercial fires in the U.S. alone include 3,675 fire fatalities and an estimated $10.7 billion
in property damage. These numbers underscore the seriousness of the issue and the need for fire-safe
construction.
Over the past 35 years, prefabricated wood I-joists and other iLevel building products have established a
record of safe and reliable performance in millions of structures. Many of these structures, such as one- or twofamily residential dwellings, do not require specific fire-resistance ratings per the building codes. The following
information is intended to help you specify and install iLevel TrusJoist brand products with fire safety in
mind.
Smoke Detectors
Smoke detectors are universally recognized as the most cost-effective life-saving
devices. While smoke detectors do not provide protection to the structure or to the
contents in a home, they do alert occupants to potential fire hazards and allow them
time to escape. Similarly, carbon monoxide detectors can also alert occupants to
faulty heating appliances or air contamination in the early stages of a fire.
5. Optional when used with resilient channels. Minimum 31/2" thick glass fiber
insulation or non-combustible insulation that is rated R-30 or less.
One-Hour Assembly
1. 48/24 tongue-and-groove, span-rated sheathing (Exposure 1)
Note
Resilient channels may be installed between the joists and g ypsum board if
improved STC and IIC sound r atings are desired.
For more information on fire assemblies and fire-safe construction,
please refer to the iLevel Fire Facts Guide (Reorder #1500) or
visit www.iLevel.com and www.i-joist.com
14
February 2008
Bend tab
and fasten
Seat the joist tight to the bottom of the hanger. When using hangers with tabs, bend
the flange tabs over and nail to the TJI joist bottom flange.
Placing a dab of subfloor adhesive in the seat of the hanger prior to installing the joist
can reduce squeaks.
Nail interior partitions to the joists when possible. If the wall can be nailed only to the
floor panel, run a bead of adhesive under the wall and either cross nail, nail through
and clinch tight, or screw tightly into the wall from below.
Avoid Shiners
Prevent Shrinkage
Movement
Gaps develop as
sheathing shrinks
Keep building materials dry, and properly glue floor panels to the joists. Panels that
become excessively wet during construction shrink as they dry. This shrinkage may
leave gaps that allow the panel to move when stepped on.
Shiner
Exercise care when nailing. Nails that barely hit the joists (shiners) do not hold the
panel tight to the joist and should be removed. If left in, the nails will rub against the
side of the joist when the panel deflects.
For more information and tips on how to prevent floor noise, refer to the
iLevel Prevention and Repair of Floor System Squeaks Technical Resource Sheet (Reorder #9009) or contact your iLevel representative.
February 2008
15
Depth
9 1 2 "
117 8"
16"
14"
16"
9 1 2 "
117 8"
19.2"
14"
16"
9 1 2 "
117 8"
24"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
Non-Snow (125%)
20LL + 15DL
20LL + 20DL
Low
High
Low
High
19'-3"
17'-2"
18'-4"
16'-3"
20'-5"
18'-2"
19'-5"
17'-3"
21'-0"
18'-9"
20'-0"
17'-9"
23'-0"
20'-6"
21'-11"
19'-5"
24'-4"
21'-9"
23'-3"
20'-7"
25'-1"
22'-5"
23'-11"
21'-3"
27'-9"
24'-9"
26'-5"
23'-5"
31'-11"
28'-6"
30'-5"
27'- 0"
26'-3"
23'-5"
25'- 0"
22'-2"
27'-9"
24'-9"
26'-5"
23'-5"
28'-7"
25'-6"
27'-2"
24'-2"
31'-6"
28'-2"
30'-0"
26'-8"
36'-3"
32'-4"
34'-6"
30'-7"
30'-9"
27'-5"
29'-4"
26'- 0"
31'-8"
28'-3"
30'-2"
26'-9"
34'-11"
31'-2"
33'-3"
29'-6"
40'-1"
35'-9"
38'-2"
33'-11"
18'-1"
16'-1"
17'-3"
15'-3"
19'-2"
17'-1"
18'-3"
16'-2"
19'-9"
17'-7"
18'-10"
16'-8"
21'-7"
19'-3"
20'-7"
18'-3"
22'-11"
20'-5"
21'-10"
19'-4"
23'-7"
21'-1"
22'-6"
19'-11"
26'-1"
23'-3"
24'-10"
22'-0"
30'- 0"
26'-9"
28'-7"
25'-4"
24'-6"
22'- 0"
22'-9"
20'-10"
26'-0"
23'-3"
24'-10"
22'-0"
26'-10"
23'-11"
25'-7"
22'-8"
29'-7"
26'-5"
28'-2"
25'-0"
34'-0"
30'-4"
32'-5"
28'-9"
28'-8"
25'-9"
26'-9"
24'-5"
29'-9"
26'-7"
28'-2"
25'-2"
32'-10"
29'-3"
31'-3"
27'-9"
37'-8"
33'-7"
35'-10"
31'-10"
16'-9"
14'-11"
15'-11"
14'-2"
17'-9"
15'-10"
16'-11"
15'- 0"
18'-3"
16'-4"
17'-5"
15'-5"
20'-0"
17'-10"
18'-9"
16'-11"
21'-2"
18'-11"
20'-2"
17'-11"
21'-10"
19'-6"
20'-10"
18'-5"
24'-1"
21'-6"
23'- 0"
20'-5"
27'-9"
24'-9"
26'-5"
23'-6"
21'-10"
20'-4"
20'-4"
19'-1"
24'- 0"
21'-6"
22'-4"
20'-5"
24'-10"
22'-2"
23'-7"
21'- 0"
27'-5"
24'-6"
26'-1"
23'-2"
31'-6"
28'-1"
30'- 0"
26'-8"
25'-8"
23'-11"
23'-11"
22'-4"
27'-1"
24'-7"
25'-2"
23'-3"
30'-4"
27'-1"
28'-11"
25'-8"
34'-10"
31'-2"
33'-2"
29'-6"
See page 17 for General Notes and information on how to use this table
16
February 2008
50LL + 15DL
Low
High
15'-6"
14'-3"
16'-7"
15'-1"
17'-1"
15'-6"
17'-6"
16'-11"
19'-2"
18'-0"
20'-3"
18'-7"
22'-7"
20'-6"
26'- 0"
23'-7"
19'-1"
18'-5"
20'-11"
20'-3"
22'-0"
21'-1"
25'-8"
23'-4"
29'-6"
26'-9"
22'-4"
21'-8"
23'-7"
22'-10"
26'- 0"
25'-10"
31'-8"
29'-8"
14'-2"
13'-4"
15'-7"
14'-2"
16'-1"
14'-7"
16'- 0"
15'-5"
17'-6"
16'-11"
18'-5"
17'-5"
21'-2"
19'-3"
24'-4"
22'-2"
17'- 0"
16'-10"
18'-10"
18'-5"
20'-1"
19'-5"
21'-7"
21'-8"
26'-5"
25'-2"
18'-10"
19'-8"
21'-2"
20'-9"
21'-7"
21'-8"
26'-5"
25'-5"
12'-8"
12'-3"
13'-11"
13'-1"
14'-8"
13'-6"
13'-7"
13'-10"
15'-0"
15'-2"
16'-6"
16'- 0"
17'-3"
17'-4"
21'-1"
20'-3"
13'-7"
14'-2"
15'-0"
15'-8"
16'-11"
16'-7"
17'-3"
17'-4"
21'-1"
20'-3"
15'-0"
15'-8"
16'-11"
16'-7"
17'-3"
17'-4"
21'-1"
20'-3"
Horizontal length = L
2. If your slope is 6/12 or less, use the Low slope column. If it is between 6/12 and
12/12, use the High column.
Add D factor
to obtain proper
cut length
3. Scan down the column until you find a span that meets or exceeds the span of
your application.
D
General Notes
Lx
e
lop
tor
fac
ngt
t le
Cu
A support beam or wall at the high end is required. Ridge board a pplications do
not provide adequate support.
D Factors
Depth
9 1 2 "
117 8"
14"
16"
212 in 12
2"
212"
3"
33 8"
3 in 12
23 8 "
3"
312"
4"
312 in 12
278"
312"
418"
434"
4 in 12
314"
4"
434"
53 8"
412 in 12
358"
412"
514"
6"
5 in 12
4"
5"
578"
634"
Slope
6 in 12
434"
6"
7"
8"
7 in 12
558"
7"
814"
93 8 "
8 in 12
63 8"
8"
93 8 "
1034"
9 in 12
718"
9"
1012"
12"
10 in 12
8"
10"
1134"
1338"
11 in 12
834"
11"
1278"
1434"
12 in 12
912"
1178"
14"
16"
3 in 12
1.031
312 in 12
1.042
4 in 12
1.054
412 in 12
1.068
5 in 12
1.083
6 in 12
1.118
7 in 12
1.158
8 in 12
1.202
9 in 12
1.250
10 in 12
1.302
11 in 12
1.357
12 in 12
1.414
Slope Factors
Slope
Factor
212 in 12
1.021
February 2008
17
roof framing
WARNING
Joists are unstable until
laterally braced.
See Warning Notes on page 5.
Safety bracing (1x4 minimum) placed
at 8' on-center (6' on-center for TJI
110 joists) and extended to a braced
end wall. Fasten at each joist with two
8d (0.113" x 212") nails minimum.
General Notes
Unless otherwise noted, all details are valid to a maximum slope of 12/12.
Web stiffeners are required if the sides of the hanger do not laterally support at
least 38" of the TJI joist top flange.
Intermediate Bearing
(312" minimum bearing required)
18
February 2008
roof details
Birdsmouth Cut
Shear blocking
114" TimberStrand LSL
rim board, iLevel 118"
rim board, or TJI joist
13
Variable slope
seat connector
R1
13
R3
TJI joist
flange must
bear fully on
plate
Two rows 8d
(0.113" x 212") nails
at 8" on-center
0" m
4'- imu
n
mi
112"
R7
W
Birdsmouth
cut must not
overhang
inside face
of plate
Birdsmouth Cut
Intermediate Bearing
R7
R5
"
2'-0 um
m
i
x
ma
R7
S
"
2'-0 um
xim
a
m
R8
Birdsmouth Cut
0" m
4'- imu
n
i
m
Two rows 8d
(0.113" x 212") nails
at 8" on-center
0" m
4'- imu
n
i
m
Filler
Beveled
2x4 block
R9
"
2'-0 um
xim
a
m
R10
19
roof details
Birdsmouth Cut
R14
Strap nails:
Leave 238"
minimum
end distance,
typical
Blocking as
required
End wall
2x_ overhang. Notch around
TJI joist top flange.
BC
Backer block: Install tight to bottom
flange (tight to top flange with top flange
hangers). Attach with ten 10d (0.128" x 3")
nails, clinched when possible.
Additional blocking
may be required for
shear transfer
H5 H5S
H6 H6S
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 2
1 3
1 2
1 3
SB
For TJI joists with slopes of 10/12 to 12/12, the vertical depth at bearing will require 114" TimberStrand LSL or
iLevel 118" rim board (for shear blocking) that is one size deeper than the TJI joist
Product Storage
110
91 2" or
14"
117 8"
2x6
5 8"
2x8
or 34"
210
91 2" or
117 8"
2x6 + 38"
sheathing
34"
14" or
16"
2x8 + 38"
sheathing
or 7 8"
230 or 360
91 2" or
14" or
117 8"
16"
2x6 + 12"
2x8 + 12"
sheathing
sheathing
1" net
If necessary, increase filler and backer block height for face mount hangers and maintain
560
Two
2x6
14" or
16"
Two
2x8
2x6
2x8
117 8"
18"
20
February 2008
91 2"
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
6'
Total Load
Snow
115%
289
321
360
289
321
360
368
449
289
321
360
368
449
321
360
368
449
NonSnow
125%
314
349
392
314
349
392
400
488
314
349
392
400
488
349
392
400
488
8'
Total Load
Defl.
Live
Load
L/240
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Snow
115%
218
242
272
218
242
272
277
338
218
242
272
277
338
242
272
277
338
NonSnow
125%
237
263
295
237
263
295
301
368
237
263
295
301
368
263
295
301
368
Defl.
Live
Load
L/240
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
NonSnow
125%
159
176
198
159
176
198
202
246
159
176
198
202
246
176
198
202
246
Live
Load
L/240
155
*
196
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Defl.
Snow
115%
175
194
218
175
194
218
223
272
175
194
218
223
272
194
218
223
272
NonSnow
125%
190
211
237
190
211
237
242
295
190
211
237
242
295
211
237
242
295
Live
Load
L/240
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Defl.
Snow
115%
146
162
182
146
162
182
186
227
146
162
182
186
227
162
182
186
227
14'
Total Load
Snow
115%
109
131
145
125
139
156
159
195
125
139
156
159
195
139
156
159
195
NonSnow
125%
118
142
158
136
151
170
173
212
136
151
170
173
212
151
170
173
212
Defl.
Live
Load
L/240
101
118
128
*
*
*
*
*
*
*
*
*
*
*
*
*
*
16'
Total Load
Snow
115%
83
100
112
106
122
137
140
170
110
122
137
140
170
122
137
140
170
NonSnow
125%
91
108
118
115
132
149
152
185
119
132
149
152
185
132
149
152
185
Defl.
Live
Load
L /240
69
81
88
*
*
146
*
*
*
*
*
*
*
*
*
*
*
91 2"
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
18'
Total Load
20'
Total Load
Defl.
Defl.
Snow
115%
NonSnow
125%
Live
Load
L/240
Snow
115%
NonSnow
125%
Live
Load
L/240
77
84
84
101
112
124
152
98
108
122
124
152
108
122
124
152
77
84
91
109
121
135
165
106
118
132
135
165
118
132
135
165
58
63
82
96
105
*
*
*
*
*
*
*
*
*
*
*
82
91
112
137
80
97
107
112
137
97
110
112
137
89
98
122
148
87
105
117
122
148
106
119
122
148
71
78
103
*
*
103
112
*
*
*
*
*
*
26'
Total Load
Defl.
28'
Total Load
Defl.
Snow
115%
NonSnow
125%
Live
Load
L/240
Snow
115%
NonSnow
125%
Live
Load
L/240
Snow
115%
NonSnow
125%
Live
Load
L/240
Snow
115%
NonSnow
125%
Live
Load
L /240
75
102
124
79
105
135
59
78
117
82
114
82
122
61
91
97
97
73
79
79
59
80
89
102
124
89
100
102
124
87
96
111
135
96
108
111
135
79
86
*
*
*
*
*
*
75
93
114
77
85
93
114
81
101
124
83
93
101
124
67
88
*
*
90
*
*
86
105
94
114
70
104
76
98
76
106
57
85
86
105
79
94
114
72
*
*
80
98
87
106
76
*
Slope Factors
Slope
Factor
21 2 in 12
1.021
3 in 12
1.031
31 2 in 12
1.042
4 in 12
1.054
41 2 in 12
1.068
5 in 12
1.083
6 in 12
1.118
7 in 12
1.158
8 in 12
1.202
General Notes
2. Select appropriate Roof Joist Horizontal Clear Span. For slopes greater than 2"
in 12", approximate the increased dead load by multiplying the joist horizontal
clear span by the Slope Factor above.
3. Scan down the column to find a TJI joist that meets or exceeds actual total load.
Total Load values are limited to deflection of L/180. For stiffer deflection criteria,
use the Live Load L/240 values.
9 in 12
1.250
10 in 12
1.302
11 in 12
1.357
12 in 12
1.414
February 2008
21
Joist
Depth
91 2"
117 8"
14"
16"
TJI
Hanger
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
ITS1.81/9.5
ITS2.06/9.5
ITS2.37/9.5
ITS1.81/11.88
ITS2.06/11.88
ITS2.37/11.88
ITS2.37/11.88
ITT411.88
ITS1.81/14
ITS2.06/14
ITS2.37/14
ITS2.37/14
ITT414
ITT2.1/16
MIT3516
MIT3516
MIT416
Nailing
Capacity
(lbs)
Header
Joist
1,365
10d
N.A.
1,365
10d
N.A.
1,365
10d
N.A.
1,365
10d
N.A.
1,365
10d
N.A.
1,365
10d
N.A.
1,365
10d
N.A.
1,300
10d
10d x 112"
1,365
10d
N.A.
1,365
10d
N.A.
1,365
10d
N.A.
1,365
10d
N.A.
1,300
10d
10d x 112"
1,300
10d
10d x 112"
2,115
16d
10d x 112"
2,115
16d
10d x 112"
2,115
16d
10d x 112"
Hanger
IUS1.81/9.5
IUS2.06/9.5
IUS2.37/9.5
IUS1.81/11.88
IUS2.06/11.88
IUS2.37/11.88
IUS2.37/11.88
IUS3.56/11.88
IUS1.81/14
IUS2.06/14
IUS2.37/14
IUS2.37/14
IUS3.56/14
IUS2.06/16
IUS2.37/16
IUS2.37/16
IUS3.56/16
Nailing
Capacity
(lbs)
Header
Joist
935
10d
N.A.
935
10d
N.A.
935
10d
N.A.
1,170
10d
N.A.
1,170
10d
N.A.
1,170
10d
N.A.
1,170
10d
N.A.
1,405
10d
N.A.
1,405
10d
N.A.
1,405
10d
N.A.
1,405
10d
N.A.
1,405
10d
N.A.
1,405
10d
N.A.
1,640
10d
N.A.
1,640
10d
N.A.
1,640
10d
N.A.
1,640
10d
N.A.
SUR/L1.81/9
SUR/L2.1/9
SUR/L2.37/9
SUR/L1.81/11
SUR/L2.1/11
SUR/L2.37/11
SUR/L2.37/11
SUR/L410
SUR/L1.81/14
SUR/L2.1/11
SUR/L2.37/14
SUR/L2.37/14
SUR/L414
SUR/L2.1/11
SUR/L2.37/14
SUR/L2.37/14
SUR/L414
Joist
Depth
91 2"
117 8"
14"
16"
TJI
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
Nailing
Capacity
(lbs)
Header
Joist
MIT49.5
2,115
16d
10d x 112"
MIT4.28/9.5
2,115
16d
10d x 112"
MIT359.5-2
2,115
16d
10d x 112"
MIT411.88
2,115
16d
10d x 112"
MIT4.28/11.88 2,115
16d
10d x 112"
MIT3511.88-2
2,115
16d
10d x 112"
MIT3511.88-2
2,115
16d
10d x 112"
B7.12/11.88
3,355
16d
16d
MIT414
2,115
16d
10d x 112"
MIT4.28/14
2,115
16d
10d x 112"
MIT3514-2
2,115
16d
10d x 112"
MIT3514-2
2,115
16d
10d x 112"
B7.12/14
3,355
16d
16d
LBV4.28/16
2,460
16d
10d x 112"
LBV4.75/16
2,460
16d
10d x 112"
LBV4.75/16
2,460
16d
10d x 112"
B7.12/16
3,355
16d
16d
Hanger
Hanger
MIU3.56/9
MIU4.28/9
MIU4.75/9
MIU3.56/11
MIU4.28/11
MIU4.75/11
MIU4.75/11
HU412-2
MIU3.56/14
MIU4.28/14
MIU4.75/14
MIU4.75/14
HU414-2
MIU4.28/16
MIU4.75/16
MIU4.75/16
HU414-2
Nailing
Capacity
(lbs)
Header
Joist
2,270
16d
10d x 112"
2,270
16d
10d x 112"
2,270
16d
10d x 112"
2,840
16d
10d x 112"
2,840
16d
10d x 112"
2,840
16d
10d x 112"
2,840
16d
10d x 112"
2,145
16d
16d
3,125
16d
10d x 112"
3,125
16d
10d x 112"
3,125
16d
10d x 112"
3,125
16d
10d x 112"
2,680
16d
16d
3,410
16d
10d x 112"
3,410
16d
10d x 112"
3,410
16d
10d x 112"
2,680
16d
16d
TJI
110
210
230
360
560
Nailing
Hanger Capacity
(lbs)
Header
Joist
VPA25
1,050
10d
10d x 112"
VPA2.1 1,230
10d
10d x 112"
VPA35
1,230
10d
10d x 112"
VPA35
1,230
10d
10d x 112"
VPA4
1,230
10d
10d x 112"
General Notes
Bold italic hangers require web stiffeners.
Joist
Capacities will vary with different nailing criteria or other support conditions; contact your iLevel
representative for assistance.
TJI
Hanger
110
210
230
360
560
LSSUI25
LSSU2.1
LSSUI35
LSSUI35
LSSU410
Capacity (lbs)
Nailing
Sloped
Sloped and Header
Joist
Only
Skewed
1,110
995
10d
10d x 112"
1,110
995
10d
10d x 112"
1,110
995
10d
10d x 112"
1,110
995
10d
10d x 112"
2,430
1,625
16d
10d x 112"
Hanger capacities shown are either joist bearing capacity or hanger capacitywhichever
is less. Joist end reaction must be checked to ensure it does not exceed the capacity shown
in the tables.
Use sloped seat hangers and beveled web stiffeners when TJI joist slope exceeds 14" per foot.
Leave 116" clearance (18" maximum) between the end of the supported joist and the header or
hanger.
22
Nailing
Capacity
(lbs)
Header
Joist
1,595
16d
10d x 112"
1,595
16d
10d x 112"
2,015
16d
10d x 112"
2,130
16d
10d x 112"
2,130
16d
10d x 112"
2,305
16d
10d x 112"
2,305
16d
10d x 112"
1,860
16d
16d
2,500
16d
10d x 112"
2,130
16d
10d x 112"
2,590
16d
10d x 112"
2,590
16d
10d x 112"
2,395
16d
16d
2,130
16d
10d x 112"
2,590
16d
10d x 112"
2,590
16d
10d x 112"
2,395
16d
16d
Hanger
February 2008
Joist
Depth
91 2"
117 8"
14"
16"
TJI
Hanger
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
THO17950
TFL2095
TFL2395
THO17118
TFL20118
TFL23118
TFL23118
THO35118
THO17140
TFL2014
TFL2314
TFL2314
THO35140
TFL2016
TFL2316
TFL2316
THO35160
Nailing
Capacity
(lbs)
Header
Joist
950
10d
10d x 112"
1,045
10d
10d x 112"
1,095
10d
10d x 112"
950
10d
10d x 112"
1,045
10d
10d x 112"
1,095
10d
10d x 112"
1,145
10d
10d x 112"
1,430
10d
10d x 112"
1,215
10d
10d x 112"
1,045
10d
10d x 112"
1,095
10d
10d x 112"
1,145
10d
10d x 112"
1,430
10d
10d x 112"
1,045
10d
10d x 112"
1,095
10d
10d x 112"
1,145
10d
10d x 112"
1,430
10d
10d x 112"
Hanger
THF17925
THF20925
THF23925
THF17112
THF20112
THF23118
THF23118
THF35112
THF17140
THF20140
THF23140
THF23140
THF35140
THF20157
THF23160
THF23160
THF35157
Nailing
Capacity
(lbs)
Header
Joist
910
10d
10d x 112"
910
10d
10d x 112"
1,220
10d
10d x 112"
910
10d
10d x 112"
910
10d
10d x 112"
1,220
10d
10d x 112"
1,265
10d
10d x 112"
1,460
10d
10d x 112"
950
10d
10d x 112"
1,045
10d
10d x 112"
1,220
10d
10d x 112"
1,265
10d
10d x 112"
1,460
10d
10d x 112"
1,400
10d
10d x 112"
1,220
10d
10d x 112"
1,265
10d
10d x 112"
1,460
10d
10d x 112"
91 2"
117 8"
14"
16"
SKH1720L /R
SKH2020L /R
SKH2320L /R
SKH1720L /R
SKH2020L /R
SKH2320L /R
SKH2320L /R
SKH410L /R
SKH1720L /R
SKH2020L /R
SKH2324L /R
SKH2324L /R
SKH414L /R
SKH2024L /R
SKH2324L /R
SKH2324L /R
SKH414L /R
Nailing
Capacity
(lbs)
Header
Joist
915
10d
10d x 112"
1,015
10d
10d x 112"
1,065
10d
10d x 112"
915
10d
10d x 112"
1,015
10d
10d x 112"
1,065
10d
10d x 112"
1,110
10d
10d x 112"
1,460
16d
16d
915
10d
10d x 112"
1,015
10d
10d x 112"
1,065
10d
10d x 112"
1,110
10d
10d x 112"
1,460
16d
16d
1,015
10d
10d x 112"
1,065
10d
10d x 112"
1,110
10d
10d x 112"
1,460
16d
16d
Variable Slope Seat Connector (5)
Joist
Depth
Hanger
TJI
Hanger
110
210
230
110
210
230
360
560
110
210
230
360
560
210
230
360
560
THO35950
THO20950-2
THO23950-2
THO35118
THO20118-2
THO23118-2
THO23118-2
BPH71118
THO35140
THO20140-2
THO23140-2
THO23140-2
BPH7114
THO20160-2
THO23160-2
THO23160-2
BPH7116
Nailing
Capacity
(lbs)
Header
Joist
2,050
10d
10d x 112"
2,330
16d
10d
2,680
16d
10d
2,050
10d
10d x 112"
2,330
16d
10d
2,680
16d
10d
2,770
16d
10d
3,185
16d
10d
2,100
10d
10d x 112"
2,330
16d
10d
2,680
16d
10d
2,770
16d
10d
3,185
16d
10d
2,330
16d
10d
2,680
16d
10d
2,770
16d
10d
3,185
16d
10d
Hanger
THF35925
THF20925-2
THF23925-2
THF35112
THF20112-2
THF23118-2
THF23118-2
HD7120
THF35140
THF20140-2
THF23140-2
THF23140-2
HD7140
THF20140-2
THF23160-2
THF23160-2
HD7160
Nailing
Capacity
(lbs)
Header
Joist
1,370
10d
10d x 112"
1,390
10d
10d
1,625
10d
10d
1,825
10d
10d x 112"
1,855
10d
10d
1,855
10d
10d
1,855
10d
10d
2,240
16d
10d
2,165
10d
10d x 112"
2,320
10d
10d
2,435
10d
10d
2,500
10d
10d
2,800
16d
10d
2,320
10d
10d
2,435
10d
10d
2,530
10d
10d
2,920
16d
10d
TJI
110
210
230
360
560
Nailing
Hanger Capacity
(lbs)
Header
Joist
TMP175
1,150
10d
10d x 112"
TMPH175 1,485
10d
10d x 112"
TMP21
1,290
10d
10d x 112"
TMPH21
1,565
10d
10d x 112"
TMP23
1,460
10d
10d x 112"
TMPH23
1,580
10d
10d x 112"
TMP23
1,505
10d
10d x 112"
TMPH23
1,630
10d
10d x 112"
TMP4
1,725
10d
10d x 112"
TMPH4
1,855
10d
10d x 112"
Support Requirements
Support material assumed to be iLevel engineered lumber or sawn lumber (Douglas fir or southern
pine species).
Minimum support width for single- and double-joist top mount hangers is 3" (112" for ITT hangers).
Minimum support width for face mount hangers with 10d and 16d nails is 134" and 2", respectively.
Footnotes:
(1) Face mount hanger capacities may be increased up to 15% for snow roofs or 25% for non-snow roofs. Maximum
increase for LSSU, LSSUI, and LSSH hangers is 15%.
(2) VPA connectors are allowed on slopes of 3/12 through 12/12 only.
(3) LSSU, LSSUI and LSSH hangers can be field adjusted for slopes and skews of up to 45 degrees. Additional lateral
restraints are required for 16" deep TJI joists.
(4) Miter cut is required at end of joist.
(5) TMP connectors are allowed on slopes of 1/12 through 6/12 only, and TMPH connectors are allowed on slopes of
6/12 through 12/12 only.
Joist
TJI
Hanger
110
210
230
360
560
LSSH179
LSSH20
LSSH23
LSSH23
LSSH35
Capacity (lbs)
Nailing
Sloped Sloped and Header
Joist
Only
Skewed
1,140
1,140
10d
10d x 112"
1,140
1,140
10d
10d x 112"
1,140
1,140
10d
10d x 112"
1,140
1,140
10d
10d x 112"
1,590
1,590
16d
10d x 112"
February 2008
23
ROOF SOLUTIONS
FLOOR SOLUTIONS
CONTACT US
OUR GUARANTEE
1.888.iLevel8 (1.888.453.8358)
www.iLevel.com
iLevel@weyerhaeuser.com
2910 East Amity Road
Boise, ID 83716
208.364.3600
P.O. Box 8449
Boise, ID 83707-2449
February 2008
Reorder TJ-4000
This document supersedes all
previous versions. If this is more
than one year old, contact your
dealer or iLevel rep.
NW