Basic Characteristics:
Flow Chart:
Protection Assembly:
Determined on the basis of criteria : power output, type of the set, customers requirements, price
Selection of manufakturers : SIEMENS, ABB, ALSTHOM, SEG, General Electric
Supply of further service components : notebook, source case for protection testing
Possibility of delivering stand-by protections using the TE 5401 system
Possibility of interconnecting protections via communication line and connection to the central control
Flow chart of protections coded according to IEC 617 numeric codes:
81 - overfrequency and underfrequency
27 - undervoltage for blocking
59 - overvoltage, two-stages
64 F - rotor earth fault
32R - reverse power
87 G - differentia
67N - stator earth fault, directiona
40 - loss of field and asynchron.oper.
50 - def. time overcurrent, blocked by U<
51 - inverse time overcurrent
46 - unbalanced load
Supply possibility of protections of transformers, bus-bars, mains - complex protecion solution
Flow Chart:
Ochrany genertoru:
Monitorovac systm:
Regultor buzen:
mikroprocesorov regulace
regulan smyky napt, napt se statikou, cos j, jalov vkon
ochrann funkce: omezovae stator. a rotorovho proudu, hldn podbuzen, U/f funkce
MOTORS
Basic Charakteristics:
Optimum solution from the view point of field energy and speed of field suppression
Type series:
Type
Use
BBS / G
BBS / M
Flow chart:
MOTORS
Basic Characteristics:
Type series:
Type
Use
SBS 0 / G
SBS 1 / G
SBS 2 / G
SBS 3 / G
SBS 4 / G
SBS / M
Technical Parameters:
Dimensions and weight:
Type
width
(mm)
depth
(mm)
height
(mm)
Ibn
A
Ibmax
A
weight
(kg)
SBS0
1000
600
2 100
150
300
230
SBS1
1000
800
2 100
400
750
350
SBS2
1200
800
2 100
600
1100
600
SBS3
1200
800
2 100
800
1500
900
SBS4
1600
800
2 100
2000
3000
1600
Flow Chart:
Possibility of field cubicle completing with complete generator and/or motor protection
Choice possibility of regulation: Voltage - Power factor - Reactive power - Field current
Implemented additional functions in AVR: stator and rotor current limiters, protection against machine
oversaturation U/f, keeping guard over underexcitation limit
Stand-by system of generator protections in AVR
RS 485 serial communication interface by Modbus RTU protocol for connect. to central control
Possibility of extension of AVR algorithms with auxil. drives control and set appliances control
Diagnostic functions in AVR making putting into operation and operation checking easier
Complete measuring of currents, voltages, outputs, power factor on the AVR display
Fitting of AVR with EEPROM memory for storage of parameters for putting into operation
Fitting of regulator with history and statistics for operation monitoring and set failure analysis.
Flow Chart:
Component Specification:
Component Specification:
Source set - choice of prestigious producers, according to the customers requirements
Output wiring and connection of LV and HV generators into power network
Zero point solution
Measuring and monitoring
Digital protections of generator (General Electric, ABB, Siemens, Alsthom, SEG)
Manual and automatic synchronizing instruments
Power plant home consumption
Connection to central control system and/or local control with PC and visualization
Electronic soft-starters of L.V. squirrel-cage motors of output power from 100 kW to 700 kW and H.V.
squirrel-cage motors of output power from 300 kW to 1500 kW for low starting-load torque
Programmable microprocessor control enables working comfort, fexibility and a number of additional
functions
Stepless and smooth control of voltage, torque and motor-speed according to required course of
starting
Compact solution in one cubicle
Turn-key supply including service
Flow Chart:
Flow Chart: