Академический Документы
Профессиональный Документы
Культура Документы
Bases Tcnicas
1) Red Multiservicio
de S.T.C.
ANEXO TCNICO
Pg. 1 de 78
INTRODUCCIN.......................................................................................................................................................................... 4
2.
OBJETIVOS .................................................................................................................................................................................. 4
3.
ARQUITECTURA DE LA SOLUCIN...................................................................................................................................... 5
3.1.
INFRAESTRUCTURA DE FIBRA PTICA ............................................................................................................................6
3.2.
ELECTRNICA DE RED ........................................................................................................................................................7
3.3.
GESTIN DEL TRFICO DE RED.........................................................................................................................................9
3.3.1. Gestin de Trfico a Nivel 2......................................................................................................................................10
3.3.2. Gestin de Trfico a Nivel 3......................................................................................................................................10
3.3.3. Calidad de Servicio ....................................................................................................................................................11
3.3.4. Transporte de Canales Sncronos............................................................................................................................12
3.4.
SISTEMAS DE GESTIN DE RED .......................................................................................................................................12
4.
5.
CONDICIONES DE INSTALACIN.......................................................................................................................................46
5.1.
5.2.
5.3.
5.4.
6.
DOCUMENTACIN...................................................................................................................................................................58
6.1.
DOCUMENTACIN TCNICO-ECONMICA ............................................................................................................58
6.2.
DOCUMENTACIN DE ESTUDIOS ..............................................................................................................................59
6.3.
3. DOCUMENTACIN DE OPERACIN Y MANTENIMIENTO..............................................................................61
3.6.1. Documentacin preliminar .......................................................................................................................................62
3.6.2. Documentacin definitiva .........................................................................................................................................62
7.
8.
CAPACITACIN........................................................................................................................................................................63
Pg. 2 de 78
CONDICIONES DE LA GARANTA...............................................................................................................................65
PROLONGACIN DE LA GARANTA ..........................................................................................................................66
VICIOS OCULTOS .............................................................................................................................................................67
CONSIDERACIONES HASTA LA RECEPCIN PROVISIONAL..............................................................................67
MANTENIMIENTO PREVENTIVO Y CORRECTIVO DURANTE LA GARANTA ...............................................68
10.
11.
11.1.
TOPOLOGA .........................................................................................................................................................................72
11.1.1
Estructura Jerrquica...........................................................................................................................................73
11.1.2
Funciones ................................................................................................................................................................74
Pg. 3 de 78
1. INTRODUCCIN
La red de servicio del Sistema de Transporte Colectivo (S.T.C.) esta integrada por 175 estaciones, 7
talleres y varias reas administrativas, prestandose en todas estas ubicaciones diferentes servicios.
Esta dispersin geogrfica de ubicaciones, y por tanto de servicios, y la futura implantacin de servicios
centralizados (como Video-Vigilancia, Video-Audimetro, Alarmas, etc) hace que sea necesario contar
con una infraestructura de comunicaciones que permita interconectar todos estos elementos entre s, de
forma que se puedan prestar los servicios de forma remota e integrada.
El presente documento define los objetivos y requisitos con los que deber contar la Nueva Red de
Comunicaciones Multiservicio de S.T.C.
2. OBJETIVOS
El objetivo de la Red de Comunicaciones Multiservicio del STC es permitir interconectar las diferentes
ubicaciones entre s, a travs de un soporte de transmisin nico de alta capacidad, que permita la
transmisin de datos, voz y video.
Solucion IP de extremo a extremo escalable que permita la convergencia de todo tipo de trfico (voz,
video, datos,etc.) sobre la misma estructura y equipos, utilizando tecnologa estandar con QoS y QoE
apropiadas para todos los usuarios.
En concreto se integrarn dentro del alcance del presente proyecto:
Talleres Zaragoza
Talleres Tasquea
Talleres Ticomn Indios Verdes
Talleres El Rosario
Talleres Constitucin
Talleres La Paz
Talleres Ciudad Azteca
Pg. 4 de 78
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
rea I. la Catlica
rea Chabacano
rea Delicias
rea Juarez
rea Balbuena
rea Sevilla
rea Cuauhtemoc
rea Revolucin
rea Guelatao
rea Salto del Agua
rea Ingeniera Desarrollo de Nuevos Proyectos/ INCADE
rea Zapata
rea Guerrero
SEAT Oceana
SEAT Estrella
Deber ser construida para integrar los servicios actuales y prever la integracin de servicios futuros, por lo
que deber una solucin ampliable y responder a criterios de mxima modularidad.
Entre los servicios que se conectarn a la Red de Comunicaciones Multiservicio estarn:
Video-vigilancia
Sistema de Tarjeta Sin Contacto (Tarjeta Inteligente)
Redes LAN
Video-Audiometro.
Sistemas Integral de alarmas
Sistema de Telefona IP
Control de asistencia y horarios
etc
Dado lo crtico de los servicios a prestar sobre la Red de Comunicaciones Multiservicio, tanto el diseo
topolgico de la red, como el equipamiento elegido debern proporcionar el mximo nivel de fiabilidad
posible.
Dado que la mayor parte de los servicios previstos se basarn en el protocolo TCP/IP, la solucin de red
propuesta deber estar optimizada para este tipo de trfico, aunque debe permitir tambin el transporte de
canales sncronos (tipo serie, E1/T1, STM-1/OC-3 ,etc).
Pg. 5 de 78
3. ARQUITECTURA DE LA SOLUCIN
La Red de Comunicaciones propuesta debera integrar
Los servicios de explotacin, se operan mayoritariamente por lneas, con un puesto de control central. Esto
hace que la mayor parte del trfico vaya a mantenerse dentro de la misma lnea en la que se gener, o se
concentre en ciertos puntos centrales determinados.
La topologa de red a implementar, deber tener en cuenta estos flujos de trfico mayoritarios, y optimizarse
teniendolos en cuenta.
La Topologa propuesta deber mantener una estructura jerarquica, redundante, con una distribucin
basada en lneas.
La interconexin entre los diferentes nodos se realizar a travs de fibra ptica implementando conexiones
de alta capacidad (10 Gb como mnimo) redundadas, de forma que cada nodo cuente con al menos 2
conexiones que permitan mantener el servicio ante la caida de cualquier otro equipo o enlace.
La topologa exacta, en cuanto a nmero de Nodos de Distribucin y Troncal, as como su ubicacin, se
dejan a criterio del licitador, que deber proponer la mejor solucin desde el punto de vista tcnico y
econmico, intentando minimizar en todo momento el uso de recursos de interconexin (fibra ptica) y el
nmero de saltos para alcanzar el Puesto Central y maximizando el rendimiento de transporte de la red en
funcin de los flujos de trfico esperados.
Pg. 6 de 78
Nodos Principales
Nodos de Distribucin
Nodos de Acceso
Nodos de Red Local
Los Nodos Principales son los encargados de interconectar el trfico de todas las lneas entre s y hacia los
Puestos Centrales de Control, para lo cual se requieren equipos pticos multiplataforma de servicios de alta
velocidad en el plano de transporte, que proporcionen ancho de banda de 10 GE con posibilidad de escalar
a 320 GE, preparados para la convergencia de los sitemas de comunicacin (recomendacin ITU-T H.323)
y crear una red NGN.
La Recomendacin ITU-T Y.2001 (ITU-T H.323) expone entre sus caractersticas ms relevantes: el uso
de tecnologa de conmutacin de paquetes IP/MPLS en el plano de transporte y la separacin entre las
funciones relacionadas con el servicio y las tecnologas de transporte. Esta divisin es importante porque
permite que los servicios trabajen sin el conocimiento de la tecnologa de red y el acceso con absoluta
rapidez al plano de trasporte, pudiendo evolucionar cada uno de forma independiente. Similarmente,
permite la migracin desde las redes actuales, verticalmente separadas y especficas para diferentes
servicios, hacia una nica red capaz de ofrecer y transportar todos los servicios.
Debern ser equipos modulares de al menos 12 slots, redundados en todos sus elementos fundamentales
(fuentes de alimentacin, tarjeta procesadora, etc) y con una muy alta capacidad de gestin de trfico tanto
a nivel 2 (switching) como a Nivel 3 (routing) incluyendo protocolos de routing dinmico (RIP, OSPF,
IGRP, IS-IS, BGP, etc) y un completo soporte de Multicast.
Pg. 7 de 78
Cada Nodo Principal contar con al menos 2 interfaces pticas a 10 Gigabit Ethernet Configurables
mediante mdulos XENPAK/XFP y 14 interfaces 1 Gigabit Ethernet de alcance configurable mediante
mdulos GBIC o SFP, deberan presentar la posibilidad escalar a interfaces pticas a 10 Gigabit Ethernet
Configurables mediante mdulos XENPAK/XFP y 8 interfaces 10/100/1000BaseT para conexin de
posibles servicios locales.
El equipo contar con una amplia capacidad de crecimiento, manteniendo libres al menos el 30% de los
slots destinados a tarjetas de interfaces.
Los Nodos de Distribucin concentran el trfico procedente de los Nodos de Acceso y lo distribuyen a
los distinitos niveles de la topologa de red. Contarn con al menos 8 interfaces pticas Gigabit Ethernet de
alcance configurable mediante mdulos GBIC o SFP y deberan presentar la posibilidad escalar a interfaces
pticas a 10 Gigabit Ethernet Configurables mediante mdulos XENPAK/XFP
Los Nodos de Distribucin contarn con una alta capacidad de gestin de trfico, tanto a Nivel 2, como a
Nivel 3, incluyendo protoclos de routing dinmico (RIP, OSPF, IGRP, etc) y un completo soporte de
Multicast.
Los Nodos de Distribucin debern permitir una ampia capacidad de crecimiento por lo que debern ser
equipos modulares o apilables, tambien deben ser aptos para la NGN.
Los Nodos de Acceso sern los nodos que se instalarn en cada una de las ubicaciones (estaciones,
talleres y reas administrativas) y a ellos se enlazarn los equipos que compondrn los servicios de
explotacin.
Existirn diversos tipos de Nodo de Acceso en funcin de la complejidad del recinto al que dar servicio.
Se contemplan 3 tipos de Nodos de Acceso:
Pg. 8 de 78
Pg. 9 de 78
3.3.1.
Pg. 10 de 78
3.3.2.
Los Nodos de Red Principal, Distribucin y Acceso contarn con la capacidad de gestin trfico a nivel 3
(routing) incluyendo el soporte de protocolos estndar de routing dinmico.
El licitante deber realizar una propuesta de filosofa de direccionamiento IP y una propuesta de solucin de
routing acorde con el direccionamiento IP que defina. Evidentemente, al no poroporcionarse datos
concretos sobre los servicios, dicha propuesta no podr ser completa, pero deber reflejar la filosofa de
diseo de solucin propuesta, incluyendo al menos:
El diseo deber contemplar caminos alternativos que permitan mantener el servicio ante la caida de
cualquier equipo.
Se optimizar la convergencia de los cminos alternativos, as como el reclculo de rutas ante
situaciones de indisponibilidad de algn nodo.
Deber existir un control de trfico generado en cada estacin y que tenga como destino la misma
estacin, para que se propage a travs de la Red de Distribucin y Principal.
Se optimizarn las rutas de acceso a los Nodos Principales y Centros de Control
3.3.3.
Calidad de Servicio
La solucin de red propuesta deber contar con amplias capacidades de Calidad de Servicio (QoS) que
permitan diferenciar y clasificar el trfico circulante por la red priorizando los flujos ms estratgicos o
importantes.
Los equipos debern contar con mecanismos para
Pg. 11 de 78
3.3.4.
Aunque dentro del alcance previsto para el presente proyecto no se prev que sea necesario implementar
ninguna conexin de tipo sncrono, la red deber estar preparada para poder transportar canales sncronos
de tipo PDH (E1/T1) o SDH/SONET (hasta STM-1).
Este transporte podr ser tipo TDM (Time Division Multiplex) nativo, o emulado a travs de soluciones
estandarizadas (CESoPSN, SAToP, TDMoIP, etc).
Aunque no se incluira dentro del alcance del proyecto, el licitante deber explicar la solucin propuesta para
realizar este tipo de transporte, incluyendo una propuesta de hardware necesario para por lo menos el
transporte de canales tipo E1/T1.
El Software de Gestin de Proposito General sera un gestor SNMP en su version ms reciente, que permita
monitorear, no slo los elelemntos de red, sino tambin cualquier otro elementos compatible SNMP.
Pg. 12 de 78
4. CARCTERISTICAS
TCNICAS
EQUIPAMIENTO Y MATERIALES
DE
A continuacin se incluyen las caractersticas mnimas que debern cumplir los equipos y materiales
empleados en el presente proyecto
Pg. 13 de 78
Interfaz de acoplamiento
1.4.1.
Pg. 14 de 78
1.4.2.
Caractersticas
Menor de 15 mm 22.6
Menor de 250 kg/km 460
Minimo 1500 N
Mnimo 2000 N
220 mm
-30C +70C
De la Fibra
La fibra ptica a utilizar debe cumplir con la norma internacional ITU-T G.652.D. para transmitir
informacin en todo el espectro de longitud de onda de 1280 a 1625 nm que incluye las longitudes de
banda 1310 y 1550 nm.
1300 1322 m
0.092ps/m2-Km
Pg. 15 de 78
Atenuacin
1310
0.4 dB/km
1383
valor a 1300nm
1550
0.3 dB/km
1625
0.4 dB/km
Nmero de
vueltas
32
1550
60
100
1310
60
100
1550
60
100
1550
60
100
Longitud de
Onda (m)
Atenuacin
Inducida
(dB)
0.05
1625
2.4.1.
Pg. 16 de 78
2.4.2.
Caractersticas
Menor de 10 mm
Menor de 120 kg/km
Minimo 800 N
Mnimo 2500 N
120 mm
-30C +70C
De la Fibra
La fibra ptica a utilizar deber estar preparada para funcionar en las bandas de 850 y 1300 nanometros,
permitiendo su uso con todo tipo de conexiones, desde 10 Mbps hasta 10Gb.
Coeficiente de Atenuacin:
A 850 nanmetros 2,3 dB/Km.
A 1300 nanmetros 0,6 dB/km.
Apertura Numrica
Apertura Numrica
0,2 0,015
Dispersin Cromtica:
Longitud de Onda con cero dispersin
Pendiente de dispersin cromtica
1297 1316 m
0.101 ps/m2-Km
Pg. 17 de 78
ANSI/TIA/EIA-568-B.2-1 Categora 6
Las caractersticas mnimas de los elementos empleados para el Cableado de Pares sern las siguientes:
Cableado Horizontal
Cable de 4 pares, certificado Categora 6
Conductores de cobre slido AWG- 23
Cumpliendo con los estndares
ANSI/TIA/EIA-568-B.2-1 Categora 6
UL Listed.
Cableado Vertical
Cable de 4 pares, certificado Categora 6
Conductores de cobre slido AWG- 23
Cumpliendo con los estndares
ANSI/TIA/EIA-568-B.2-1 Categora 6
Pg. 18 de 78
UL Listed.
Tomas de Usuario
Roseta Modular de pared formada por un Face Plate doble y 2 conectores encastrables tipo RJ-45
hembra, cumpliendo con la siguiente normativa:
ANSI/TIA/EIA-568-B.2-1 Category 6 component compliant to the latest draft (9b)
IEEE 802.3ab Gigabit Ethernet verified
ETL Tested for Category 6 channel performance
UL Listed 1863
CSA Certified
FCC part 68.5, subpart F compliant
IEC-603-7 compliant
ISO 11801 Class E compliant
Repartidores (Patch-Pannel)
Paneles repartidores de 24 o 48 interfaces RJ-45.
Enracables en armarios de 19
cumpliendo con la siguiente normativa:
ANSI/TIA/EIA-568-B.2-1 Category 6 component compliant to the latest draft (9b)
IEEE 802.3ab Gigabit Ethernet verified
ETL Tested for Category 6 channel performance
UL Listed 1863
CSA Certified
FCC part 68.5, subpart F compliant
IEC-603-7 compliant
ISO 11801 Class E compliant
Certificado de laboratorio para soportar IEEE 802.3af DTE POWER
Pg. 19 de 78
ANSI/TIA/EIA-568-B.2-1 Category 6
UL Listed 1863
CSA Certified
IEC-603-7 compliant
Patch cord
ANSI/TIA/EIA-568-B.2-1 Category 6
UL Listed 1863
CSA Certified
IEC-603-7 compliant
Administradores Horizontales
Lamina de hacero 16 ga
2 unidad de rack
Pg. 20 de 78
Aplicaciones:
En el interior de locales con ambiente seco, hmedo o aceite, en conduit, ductos o charolas.
Tensin Mxima de Operacin:
600 V
Sobrecarga
Cortocircuito
105 C
150 C
Propiedades:
Pg. 21 de 78
Para permitir crecer de una forma modular, sin interferir con los elementos instalados previamente, la
interconexin a las fibras alojadas dentro de los paneles se realiar a travs de su parte delantera, mediante
frontales equipados con los conectores adecuados.
Para el presente proyecto se emplearn preferiblemente conectores SC o LC/PC para la fibra ptica
monomodo y LC o MT-RJ para la multimodo.
Cada panel contar con un frontal de al menos 36 conectores.
4.6. Gabinete
Repartidores
para
Ubicacin
de
Equipos
El gabinete para ubicacin de equipos y repartidores de cableado ser metlico, con puerta transparente
resistente a golpes.
Sus principales caractersticas
Como armarios repartidores secundarios en edificios administrativos o talleres, podrn emplearse gabinetes
murales de 3 pies, con las mismas caractersticas fisicas.
Pg. 22 de 78
Pg. 23 de 78
Debern presentar la posibilidad de ser montados en rack de 19, al interior de armarios estndar
de 23.
Doble fuente de Alimentacin, con posibilidad de alimentacin en corriente alterna o continua.
Sistema de refrigeracin con ventiladores independientes
Soporte de PoE (Power over Ethernet) IEEE 802.3af integrado en el chasis (sin necesidad de
mdulos de alimentacin externos)
Posibilidad de integrar en el chasis tarjetas de los siguientes tipos de interfaces con las siguientes
cantidades mnimas
o Fast Ethernet 10/100BaseT (RJ-45) 240 Puertos
o Fast Ethernet 10/100BaseT (R-45) con PoE (Power over Ethernet) compatible IEEE
802.3af 240 Puertos
o Fast Ethernt sobre Fibra ptica (100BaseFX / 100BaseLX) 240 Puertos
o Gigabit Ethernet Configurables mediante mdulos GBIC/SFP 244 Puertos
o 10 Gigabit Ethernet Configurables
o 10/100/1000BaseT (RJ-45) 240 puertos
o 10/100/1000BaseT (RJ-45) con soporte PoE compatible IEEE 802.3af 240 puertos
Soporte DWDM para la implementacin de varias conexiones 10 Gigabit sobre un mismo par de
fibras pticas
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
o IEEE 802.3, 100BASE-FX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
10 Gigabit Ethernet
o IEEE 802.3ae
o IEEE 802.3x
Pg. 24 de 78
IEEE 802.3aq
10GBASE-SR
10GBASE-LR
10GBASE-ER
10GBASE-ZX
Seguridad
o IEEE 802.1x
Rendimiento
Topologias soportadas
Punto a punto, add/drop lineal, anillo, estrella y malla.
Multianillo con soporte de cierre mnimo de 5 anillos en el mismo sistema y esquema de anillo de proteccin
para 2 4 fibras.
Funcionalidades de Nivel 2
Pg. 25 de 78
Soporte de Spanning Tree por VLAN (PVST+) y Rapid Spanning Tree por VLAN (PVRST)
Soporte IGMP (Internet Group Management Protocol) snooping v1, v2, v3
Soporte 802.1s, 802.1w, 802.1ad
Soporte de Jumbo Frames
Soporte de Agregacin de Canales Ethernet, Fast Ethernet o Gigabit Ethernet.
Funcionalidades de Nivel 3
Calidad de Servicio
Seguridad y Gestin
Pg. 26 de 78
o 802.1x accounting
o 802.1x authentication failure
o 802. 1x Private VLAN assignment
o 802. 1x Private Guest VLAN
o 802. 1x Radius-supplied time out
Soporte de ACLs (Access Control List) por puerto y VLAN
Soporte de DHCP.
Soporte de SSHv1 y SSHv2.
Filtrado MAC unicast.
Inspeccin dinmica ARP
Filtado por direccin MAC Unicast
Compatible SNMP v1, v2, v3.
Telnet.
TFTP (Trivial File Transfer Protocol).
RMON (Remote Monitoring).
RSPAN (Remote Switched Port Analyzer):
o Filtrado SPAN ACL
o Autoconfiguracin DHCP (Dynamic Host Configuration Protocol).
o Soporte de Enhanced SNMP MIB.
Pg. 27 de 78
Soporte DWDM para la implementacin de varias conexiones sobre un mismo par de fibras pticas.
En caso de optar por soluciones apilables, la configuracin de los equipos apilados deber ser conjunta,
como si fueran un nico equipo fsico, manteniendose todas las caractersticas definidas en todos y cada uno
de los equipos que forman la pila.
Debern presentar la posibilidad de ser montados en rack de 19, al interior de armarios estndar de 23.
Protoclos de Red Soportados
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
10 Gigabit Ethernet
o IEEE 802.3ae
o IEEE 802.3x
o IEEE 802.3aq
o 10GBASE-SR
o 10GBASE-LR
o 10GBASE-ER
o 10GBASE-ZX
VLAN trunking y tagging
o IEEE 802.1Q
o IEEE 802.3ad
Pg. 28 de 78
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Funcionalidades de Nivel 3
Pg. 29 de 78
Seguridad y Gestin
Pg. 30 de 78
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
o IEEE 802.1Q
o IEEE 802.3ad
Pg. 31 de 78
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Funcionalidades de Nivel 3
Pg. 32 de 78
Calidad de Servicio
Seguridad y Gestin
Pg. 33 de 78
4.10. Nodo
de
Acceso
para
Correspondencia de Lneas
Estacin
Con
Los Nodos de Acceso son los encargados de propocionar la conectividad a los usuarios y servicios.
En el caso de Estaciones con Correspondencia de Lneas, o reas de Edificios Administrativos Estandar,
contarn con al menos 4 interfaces Gigabit Ethernet configurables en alcance mediante mdulos GBIC o
SFP y 48 interfaces 10/100BaseT. Con capacidad de gestin de trfico tanto a nivel 2 (switching/bridging)
como a nivel 3 (routing).
Sus caractersticas mnimas debern ser:
Capacidad del Hardware
Soporte DWDM para la implementacin de varias conexiones sobre un mismo par de fibras pticas.
Doble fuente de Alimentacin, con posibilidad de alimentacin en corriente alterna o continua.
48 Interfaces 10/100/1000BaseT para acceso de usuarios y servicios, 4 Puertos Gigabit configurables en
alcance mediante mdulos GBIC o SFP para interconexin con otros nodos.
Debern presentar la posibilidad de ser montados en rack de 19, al interior de armarios estndar de 23.
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
Pg. 34 de 78
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
o IEEE 802.1Q
o IEEE 802.3ad
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Pg. 35 de 78
Funcionalidades de Nivel 3
Calidad de Servicio
Seguridad y Gestin
Pg. 36 de 78
Pg. 37 de 78
Soporte DWDM para la implementacin de varias conexiones Gigabit sobre un mismo par de fibras
pticas
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
Pg. 38 de 78
10 Gigabit Ethernet
o IEEE 802.3ae
o IEEE 802.3x
o IEEE 802.3aq
o 10GBASE-SR
o 10GBASE-LR
o 10GBASE-ER
o 10GBASE-ZX
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Pg. 39 de 78
Funcionalidades de Nivel 3
Calidad de Servicio
Seguridad y Gestin
Pg. 40 de 78
Pg. 41 de 78
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Pg. 42 de 78
Calidad de Servicio
Seguridad y Gestin
Deber componerse de dos subsistemas independientes, con la capacidad de integrarse en uno slo.
Descubrimiento de Redes
Deteccin de Problemas
Mediante una serie de procesos en background (que no necesitan actuacin por parte del
opoerador del sistema) el sistema ser capaz de descubrir todos los equipos conectados en la
red as como las posibles conexiones con otras redes diferentes redes
A travs de las tablas de rutas de los elementos deber ser capaz de crear un mapa topolgico
en el que aparezcan los nodos de la red con sus interconexiones.
Deteccin de Problemas
Pg. 44 de 78
Las alarmas sern categorizas segn su nivel crtico. Este nivel crtico deber ser definido por el
administrador del sistema.
Cualquier problema o evento detectado ser almacenado en un log, o base de datos abierta,
que permita su consulta y tratamiento a posteriori
Consola de Operacin
La operacin del software de Gestin de Red se realizar a travs de una consola grfica de facil
manejo, accesible de forma remota , con un sistema de control de acceso y validacin por usuario y
password.
Esta consola permitira gestionar la infraestructura instalada a trves de planos topolgicos, mediante el
uso de cdigos de colores.
La visualizacin de la topologa de red se deber poder realziar a diferentes niveles, siendo obligatorio
poder contar con como mnimo 5 niveles o mapas, que permitan tener vistas del estado de la red en al
menos los siguientes modos:
Pg. 45 de 78
Funcionamiento normal
Con avisos (warnings) que no afectan a su normal funcionamiento
Con errores que limitan alguna capacidad
Estado de No disponible
Permitir realizar una gestin de MIB (Management Information Base) que incluya, como mnimo la
carga, descarga y actualizacin de MIBs propietarias de los equipos instalados
Permitir la generacin de informes de inventario, rendimiento y alarmas
Inventario detallado tanto software como hardware de todo el equipamiento de red , incluyendo:
o Versiones de software
o Mdulos
o Tarjetas
o Configuraciones
Captura mensajes generados en la consola de cada nodo de una forma remota y desatendida
(Syslog Analysis).
Actualizacin de Sistema Operativo desatendidamente y de una forma planificada.
Monitorizacin de la accesibilidad y el tiempo de respuesta de los dispositivos de red.
Control de cada cambio hardware de cada dispositivo.
Control del histrico de Configuraciones de cada dispositivo, permitiendo comparar distintas
versiones.
Modificacin, borrado e incorporacin de nuevos configuraciones de una forma desatendida y
programada.
Diseo de un mapa de todos los nodos instalados permitiendo filtrar por VLAN, dominios VTP,
etc.
Creacin, modificacin y borrado de VLANs de varios de equipos de la red a la vez.
Pg. 46 de 78
Control de todos los equipos conectados a cada puerto del equipamiento. (Direccin MAC,
Direccin IP, Nombre del equipo, Usuario Conectado, etc.).
Visualizacin grfica de cada dispositivo mostrando una representacin real (tal y como es
fsicamente el equipo) con el estado en tiempo real de los mdulos, interfaces, etc.
Plataforma Hardware
Las 2 aplicaciones que integran la Plataforma de Gestin de Red debern instalarse sobre una misma
plataforma hardware.
Las caractersticas, a nivel de rendimiento (CPU, memora, disco duro, etc) de la Plataforma Hardware
debern superar de forma holgada los requerimientos definidos por los fabricantes de las aplicaciones.
Deber ser una plataforma de alta disponibilidad, que cuente con:
5. Condiciones de Instalacin
Todas las instalaciones, conexionados y tendidos de cable se realizarn conforme a las normativas
mexicanas vigentes y a los procedimientos definidos por el S.T.C. asi como los horarios prestablecidos para
estos trabajos.
A continuacin se incluyen los criterios bsicos de instalacin definidos para el presente proyecto.
Los horarios de trabajo podrn ser realizados acorde a la siguiente tabla:
Lugar
Centro Estratgico de Operaciones
Horario permitido de
Lunes a Viernes hbiles
24 hrs
Actividad a realizar
Instalacin de equipos
Estaciones
Andenes y zona de vas
Locales Tcnicos
Tendido e instalacion de
bandeja de rejilla y cable de
fibra ptica
24 hrs
Instalacin, conexionado de
equipos, armarios, fibra y
distribuidores pticos
Pg. 47 de 78
Instalacin de cableado
estructurado
Pg. 48 de 78
Pg. 49 de 78
Pg. 50 de 78
Cajas Registro
Serie Rectangular, para reas no peligrosas y a la intemperie.
Material: Aluminio libre de cobre
Acabado: Pintura electrosttica.
Tipos: FS, FSC, FSCC, FSCD, FSX
Tapas: Tapa ciega para caja registro serie rectangular tipo FS.
Pg. 51 de 78
La cantidad de cables y espacio a ocupar en los tubos ser de acuerdo a lo indicado en la norma oficial
mexicana NOM-001-SEMMP-1994.
No se deben colocar dos o ms tubos para una misma ruta y tipo de cableado. En su lugar se utilizar
un solo tubo de mayor dimetro, salvo los casos que permita la norma antes mencionada, que el
dimetro requerido rebase las 2 o bien que se trate de una seal con potencial para alimentacin, la
cual debe ir en forma independiente a las seales de datos y control.
Pg. 52 de 78
Tuberas
Ductos
Charolas
En general, cualquiera que sea el tipo de canalizacin que se emplee debe cumplir con los siguientes puntos:
Los conductores no deben introducirse en las canalizaciones sino hasta que estas hayan sido instaladas y
formen un sistema completo con todos sus accesorios.
Si se usan guas para introducir los conductores, estas debern insertarse hasta que las canalizaciones estn
instaladas en su lugar.
Para introducir los conductores no deben utilizarse lubricantes que puedan daar el aislamiento de dichos
conductores.
Cuando un tubo o ducto entre a una caja, gabinete o accesorio, debe colocarse una boquilla que evite
raspaduras en el aislamiento o cubierta de los conductores, a menos que la construccin propia del
accesorio ofrezca una proteccin equivalente.
El doblado del tubo o ducto debe hacerse con las tcnicas y herramientas adecuadas, de manera que no se
produzcan grietas y que su dimetro interior no se reduzca ms del 10%. El radio de curva interior, en el
caso de dobleces, no debe ser menor a 10 veces el dimetro exterior del tubo.
En un tramo de tubera entre dos cajas de conexin consecutivas, entre una caja y un accesorio o entre dos
accesorios no deben existir ms de dos curvas de 90 grados o su equivalente (180 grados en total),
incluyendo las curvas inmediatas a las cajas o accesorios. En su lugar se utilizarn los condulets apropiados
para cada caso, con el fin de permitir un alambrado fcil por el tubo.
En tubos y ductos cerrados, sin tapa, los conductores deben ser fsicamente continuos (sin empalmes) entre
dos cajas o entre dos accesorios consecutivos.
Debe instalarse una caja de conexiones en cada punto de empalme o derivacin de conductores o en cada
punto de interrupcin o punto de confluencia de la canalizacin, cuando la instalacin cambie de un tipo de
canalizacin a otro.
No se requieren registros para hacer derivaciones de conductores en canalizaciones que tengan tapas
removibles, tales como ductos con tapa, condulets o charolas.
El nmero mximo de conductores en una canalizacin debe respetar los factores de relleno especificados
en cada caso.
Pg. 53 de 78
Tuberas
Se utilizarn los siguientes tipos:
a) Tubo conduit metlico
b) Tubo metlico flexible
c) Tubo no metlico
A.
Su utilizacin ser general exceptundose aquellos lugares en donde se deben cruzar vas energizadas o
cuando la superficie donde sern colocadas sea muy irregular.
La seccin transversal del tubo debe ser circular.
Pg. 54 de 78
Cajas Registro
Serie Rectangular, para reas no peligrosas y a la intemperie.
Material: Aluminio libre de cobre
Acabado: Pintura electrosttica.
Tipos: FS, FSC, FSCC, FSCD, FSX
Tapas: Tapa ciega para caja registro serie rectangular tipo FS.
Empaques:
Empaque cerrado de neopreno para caja registro serie rectangular tipo FS.
Asimismo debern emplearse tapones de cierre PLG y reducciones RB a prueba de polvos,
combustible y lluvia.
La tubera debe fijarse firmemente, cuando menos cada 1.50 metros y a no ms de 75 cm de cada caja,
gabinete o accesorio, utilizando para ello abrazaderas o accesorios que no daen el tubo y que cumplan
con las siguientes caractersticas:
La cantidad de cables y espacio a ocupar en los tubos ser de acuerdo a lo indicado en la norma oficial
mexicana NOM-001-SEMMP-1994.
Pg. 55 de 78
No se deben colocar dos o ms tubos para una misma ruta y tipo de cableado. En su lugar se utilizar
un solo tubo de mayor dimetro, salvo los casos que permita la norma antes mencionada, que el
dimetro requerido rebase las 2 o bien que se trate de una seal con potencial para alimentacin, la
cual debe ir en forma independiente a las seales de datos y control.
B.
Dentro de esta designacin tenemos el tubo flexible sin forro y con forro, hecho de cinta metlica
engargolada (en forma helicoidal), el cual deber cumplir con las siguientes caractersticas:
Tubo flexible sin forro.
Tubo metlico flexible, engatillado simple, fabricado con fleje de acero galvanizado por
ambas caras.
Caractersticas del fleje: acabado mate, bordes cizallados sin galvanizar, recubrimiento de
zinc.
Temperatura mxima de uso: 300 C
Tubo metlico flexible, engatillado simple, fabricado con fleje de acero galvanizado con
una funda plstica autoextinguible adaptada a su contorno exterior para incrementar su
estanqueidad.
Caractersticas del fleje: acabado mate, bordes cizallados sin galvanizar, recubrimiento de
zinc.
Caractersticas del recubrimiento de PVC: Autoextinguible, color gris.
Temperatura mxima de uso: 70 C
Se utilizar en las entradas para los racks y gabinetes, es decir, para llevar los conductores desde
la canalizacin hasta los muebles de monitoreo o donde se resguardan los equipos de control.
Tambin podrn utilizarse en aquellos lugares en donde la superficie a la cual se fijar la
canalizacin sea muy irregular.
No deber usarse tubo metlico flexible de dimetro nominal inferior a 13 mm (1/2) ni superior a
51 mm (2).
El acoplamiento a cajas, ductos y gabinete deber hacerse usando los accesorios apropiados para este
objeto y que cumplan con lo siguiente:
Pg. 56 de 78
La cantidad de cables y espacio a ocupar en los tubos, ser de acuerdo a lo indicado en la norma
oficial mexicana NOM-001-SEMMP-1994.
No se deben colocar dos o ms tubos para una misma ruta y tipo de cableado. En su lugar se utilizar
un solo tubo de mayor dimetro, salvo los casos que permita la norma antes mencionada, que el
dimetro requerido rebase 51 mm (2), o bien que se trate de una seal con potencial para
alimentacin, la cual debe ir en forma independiente a las seales de datos y control.
C.-Tubo no metlico
La seccin transversal de este tubo debe ser circular y se utilizar nicamente cuando la instalacin
cruce vas energizadas o cuando la instalacin corra en forma paralela a las vas a menos de 2 metros de
separacin.
No deber utilizarse tubos no metlicos de dimetro nominal inferior a 13 mm (1/2) ni superior a 51
mm (2).
Los extremos de cada tubo deben quedar libres de bordes cortantes.
El material empleado para su construccin debe ser autoextinguible, resistente a la humedad, debe tener
suficiente resistencia mecnica para proporcionar adecuada proteccin a los cables y para soportar un
trato rudo durante su instalacin, por lo que el tipo de tubo que se utilice debe ser de uso rudo.
Todas las uniones entre tubos, tubos y cajas, tubos y accesorios o entre accesorios y cajas, deben
hacerse por mtodos y con los materiales adecuados para este tipo de instalacin.
Las cajas y accesorios que se empleen en las instalaciones con tubo no metlico deben ser del mismo
material que el tubo.
Cuando se empleen cajas metlicas con tubo no metlico, las cajas debern conectarse a tierra.
Las instalaciones con tubo no metlico deben fijarse a intervalos no mayores a 1.50 metros.
Adems, deben soportarse a no ms de 75 cm de cada caja, gabinete u otro extremo del tubo.
Ductos
Pg. 57 de 78
Charolas
Estos requisitos se aplican a las estructuras rgidas y continuas especialmente construidas para soportar
cables, tales como charolas, canales, escalerillas y estructuras similares.
En general, las charolas, canales y escalerillas ya se encuentran instalados en el S.T.C., por lo que no se
requiere de la instalacin de ellas.
Podrn utilizarse siempre y cuando exista espacio disponible en ellas y adems no corran por la misma
charola cables de alta tensin.
En recorridos que no sean horizontales o donde los cables no puedan mantenerse por s mismos sobre las
charolas, los cables deben sujetarse firmemente a los elementos transversales de la misma charola por
medio de cinchos.
Deben proveerse soportes para evitar esfuerzos en los cables cuando stos se deriven fuera de la charola
hacia cualquier tipo de canalizacin.
Alimentacin y Tierra Fsica de las Instalaciones
Pg. 58 de 78
La forma de alimentar y conectar a tierra fsica los equipos, ser de acuerdo a la norma oficial mexicana
NOM-001-SEMMP-1994; asimismo se dispondr de la alimentacin elctrica en los locales que se indican
a continuacin.
En el Local Tcnico nmero 2 en estaciones y en las Subestaciones de Alumbrado y Fuerza en garages y
talleres se dispondr de una alimentacin de 127 y 220 Vca + 10% a 60 Hz + 1 Hz, de la cabina
preferencial P, por lo cual el proveedor deber considerar un tablero, con las pastillas termomagnticas
necesarias para alimentar los equipos que instalar.
Este tablero servir para alimentar todos los equipos que se ubicarn en cada instalacin, por lo que dentro
de los alcances del proveedor, se incluye llevar esta alimentacin desde el Local Tcnico 2 hasta la
ubicacin fsica de los equipos.
6. Documentacin
Pg. 59 de 78
Programa detallado de realizacin del proyecto, indicando cada parte del sistema y su seguimiento, este
programa deber ser validado y aprobado por personal responsable por parte del S.T.C. A entregar
30 das naturales despus de la firma del contrato.
Proyecto de tuberas, cableado e instalacin por lnea. A entregar una semana antes del inicio de los
trabajos en la lnea afectada
Manual de instalacin y operacin general del SISTEMA que deber cubrir cuando menos los
siguientes aspectos:
Pg. 60 de 78
Manuales de instalacin y operacin particular de los equipos, que debern cubrir cuando menos los
siguientes aspectos:
a) Medidas de seguridad en la instalacin y operacin de los equipos.
b) Descripciones detalladas sobre la operacin y caractersticas particulares de cada uno de los
equipos, con sus mdulos, accesorios y controles respectivos.
c) Diagramas de principio a bloques sobre la operacin e instalacin de los equipos, con sus
mdulos, accesorios y controles respectivos.
d) Procedimientos de instalacin y configuracin de los equipos, con ejemplos de aplicaciones tpicas.
e) Instrucciones de operacin y/o programacin del software utilizado en el proyecto.
f) Gua para la localizacin de fallas y mantenimiento a primer nivel (intercambio de mdulos e
intervenciones menores en campo), el cual debe incluir las actividades de mantenimiento
preventivo y su periodicidad.
g) Especificaciones.
Esta documentacin deber entregarse antes de la finalizacin total del proyecto
Manuales de servicio de los equipos, que debern cubrir cuando menos los siguientes aspectos:
a) Medidas de seguridad en el momento de dar servicio a los equipos, mdulos, accesorios y
controles respectivos, incluyendo el tipo y caractersticas de los equipos requeridos para efectuar
el servicio.
b) Descripcin detallada de cada uno de los circuitos elctricos y electrnicos, incluyendo las fuentes
de alimentacin de los equipos y ajustes necesarios para calibrar la operacin ptima de stos.
Pg. 61 de 78
Cuaderno de pruebas que debern cubrir cuando menos los siguientes aspectos:
a) Un certificado de las pruebas de aceptacin en sitio, en donde se relacionen de manera global
todos los bienes solicitados, de acuerdo al proyecto de que se trate, indicndolos con su nombre,
marca y modelo, nmero de serie, la cantidad de elementos, el tipo de aceptacin y la fecha en
que se reciben.
b) Una relacin a detalle y por reas sobre la inspeccin fsica y pruebas funcionales practicadas a
cada uno de los equipos en donde se incluir el nmero de serie en cada uno de ellos.
c) Se debe incluir las hojas sobre los reportes de las pruebas en fbrica, as como aquellos registros
de las pruebas practicadas en campo, sobre estas ltimas, el personal del S.T.C. debe haber
firmado en dichas hojas, respecto a la validacin de las pruebas.
d) En el cuaderno se deben marcar las pruebas de tipo mecnico, elctrico que se deben practicar a
cada uno de los equipos, asimismo se deben describir los procedimientos de prueba a cumplir.
Esta documentacin deber entregarse para cada tipo de equipo una semana antes de las primeras
pruebas de aceptacin de equipo que se realicen de dicho equipo
Manual de operacin, el cual deber cubrir cuando menos los siguientes aspectos:
a) Los principios bsicos de los sistemas instalados.
b) La configuracin del SISTEMA, con la ubicacin de los equipos en las estaciones, talleres,
garajes y en los Centros de Monitoreo.
c) Los procedimientos para la operacin de cada uno de los equipos en donde se incluya el
procedimiento para la inicializacin, arranque y apagado de los mismos.
Esta documentacin deber entregarse antes de la finalizacin total del proyecto
Pg. 62 de 78
Este manual servir de base para el curso que debe impartir el proveedor al personal operativo.
El proveedor deber presentar el programa detallado de realizacin del proyecto y requerimientos a ms
tardar 30 das naturales despus de la firma del contrato para su aprobacin por parte del S.T.C.
Todos los documentos arriba indicados debern ser presentados al S.T.C. Para revisin y aprobacin en
los formatos y nmero de copias indicadas.
Para este proyecto el proveedor entregara planos que se ajustarn a las dimensionesde 0.91 metros
por 1.40 metros (dimensiones mximas), con pie de plano, cuyas caractersticas se darn
posteriormente a dicho proveedor. Los anteproyectos y proyectos ejecutivos debern tener la
autorizacin del S.T.C. y tambin debern presentar la memoria tcnica descriptiva de cada uno de
los planos para revisin y validacin del S.T.C.
3.6.1.
Documentacin preliminar
Es la documentacin de estudios previamente mencionada y total del sistema (planos, diagramas, manuales,
cuadernos, etc.) de montaje, instalacin, funcionamiento y mantenimiento de los equipos, esta informacin
dar constancia del cumplimiento de la presente especificacin.
La documentacin preliminar se utilizar como borrador para anotar las modificaciones que pudieran surgir
durante el montaje, instalacin, pruebas y puesta en servicio del sistema de vdeo vigilancia. Esta se
proporcionar en forma de reproducciones heliogrficas y/o fotocopiado, claramente legibles, para formar
dos (2) juegos, y deber ser entregada conforme se vaya desarrollando el proyecto, basndose en el
programa aprobado.
No se aceptar que la documentacin est incompleta, o que las copias no sean legibles y/o que est
desordenada, sin ndice, sin paginacin o con diagramas borrosos.
Es necesario que la documentacin sea entregada al S.T.C., de manera relacionada y cuando sea necesario
se aceptarn anexos, siempre y cuando estos estn perfectamente identificados.
Se deber entregar la documentacin preliminar en el idioma espaol.
Pg. 63 de 78
3.6.2.
Documentacin definitiva
Esta documentacin es la que comprende toda la documentacin de estudios y preliminar corregida con
base a como qued instalado y funcionando el sistema de vdeo vigilancia, en forma total y completa.
La documentacin definitiva consistir de un juego en original y 2 copias claramente legibles, que permitan el
fotocopiado cuando se requiera; el S.T.C., podr rechazar dicha documentacin si no cumple con lo antes
citado.
El plazo mximo para entregar esta documentacin ser el da de la recepcin provisional del grupo de
estaciones marcada como entregable, antes de esta fecha dicha documentacin deber ser presentada a la
Coordinacin Tcnica con por lo menos 10 das hbiles antes de concluir la instalacin del entregable al
S.T.C. para su revisin y aprobacin.
Toda esta documentacin deber presentarse en idioma espaol. Adems de los juegos de documentacin
anteriormente solicitados, el proveedor deber proporcionar esta documentacin en idioma espaol en dos
juegos de CDs, o DVDs, elaborados en procesador de textos WORD versin 2003, para WINDOWS
XP, para los manuales operativos, tcnicos y de mantenimiento; y en AUTOCAD ltima versin, lo
correspondiente a los planos, diagramas de principio, etc., que se requieran. Las versiones en que fueron
elaborados los documentos, planos, diagramas de principio, etc., debern ser indicadas en las etiquetas de
identificacin de los CD`s o DVDs.
7. Plan de Pruebas
Los procedimientos de pruebas que sern aplicados a los equipos, conjuntos o subconjuntos, son lo
siguientes:
Recepcin provisional
La recepcin provisional se considerar realizada a la puesta en servicio del equipo y/o sistema
involucrado, despus de haber pasado satisfactoriamente las pruebas realizadas en cada instalacin, segn
el programa de pruebas acordado previamente entre el proveedor y el S.T.C..
Al concluirse las pruebas de recepcin provisional, se levantar un acta donde se indiquen las condiciones
de la puesta en servicio del equipo o sistema indicndose si se declara o no recibido provisionalmente el
equipo o sistema.
Las fallas menores (que no comprometan la operacin y funcionalidad del sistema) y que hayan sido
anotadas en el acta de recepcin que no se hayan resuelto en el plazo de 15 das calendario, se
considerarn no atendidas y la garanta del equipo y/o sistema se considerar automticamente prorrogada
en el tiempo que se exceda en la resolucin de estas.
Pg. 64 de 78
Recepcin definitiva
La recepcin definitiva de los equipos suministrados ser llevada a cabo al trmino del perodo de garanta
general, si todas las obligaciones correspondientes ya fueron cumplidas, y que todas las reservas emitidas en
el acta de recepcin provisional y perodo de garanta hayan sido resueltas a satisfaccin del S.T.C.,
levantndose el acta de cumplimiento.
8. Capacitacin
El proveedor deber efectuar los estudios de ingeniera necesarios para el buen desarrollo del proyecto:
Adems, el proveedor deber proporcionar al personal que designe el S.T.C. cursos de capacitacin que
incluirn la operacin, el funcionamiento, mantenimiento y software utilizado en la programacin, as como
las recomendaciones y cuidados que se deben tener a los equipos, conjuntos y subconjuntos del sistema,
dicha capacitacin comprender:
Pg. 65 de 78
Asimismo se incluirn los temas que por la experiencia del proveedor considere necesarios para que el
personal tcnica de la Coordinacin Tcnica puede llevar a cabo las labores de mantenimiento preventivo y
correctivo tanto de los equipos en forma individual, como del sistema en si conjunto.
El lugar de imparticin del curso para el caso de las instalaciones ser en las oficinas del proveedor..
Los cursos de capacitacin para la instalacin debern ser impartidos a 20 personas divididos en 2 grupos
en turno matutino y vespertino (un grupo por turno), la fecha de inicio y horario de los cursos sern
determinados por el S.T.C., de acuerdo al programa de actividades que se defina.
El curso de capacitacin para el mantenimiento deber ser impartido a 20 personas divididos en 2 grupos
en turno matutino y vespertino (un grupo por turno), en donde la fecha de inicio y horario del curso ser
definido por el S.T.C., de acuerdo al programa de actividades que se defina.
La documentacin que servir para la imparticin de cada curso deber ser entregada al S.T.C., a ms
tardar diez das hbiles antes del inicio de la capacitacin, para su aprobacin. Esta documentacin
Pg. 66 de 78
9. Garanta y Mantenimiento
El proveedor es responsable de garantizar y mantener el buen funcionamiento del equipo o sistema
suministrado durante un plazo que se menciona a continuacin:
La reposicin de cualquier equipo, mdulo o elemento debe ser por otro igual, no aceptndose
equivalentes.
En el caso en que a pesar de las intervenciones, el funcionamiento de un aparato, subconjunto o dispositivo
continuara fallando, el proveedor estar obligado a reemplazar, por su cuenta, no solamente el elemento
daado, sino la totalidad de los elementos del mismo tipo que existan en cada conjunto o subconjunto, por
elementos de un modelo o serie diferente y equivalente sometido a la previa aceptacin del S.T.C. La
garanta para los materiales que hayan sido reemplazados por falla sistemtica se extender por un nuevo
perodo de veinticuatro (24) meses.
Todo perjuicio ocasionado a otros equipos o a la operacin del S.T.C. debido a una falla del equipo y/o
sistema en garanta o a las intervenciones del proveedor ser responsabilidad del mismo, de acuerdo a lo
establecido en las leyes mexicanas.
9.4. CONSIDERACIONES
PROVISIONAL
HASTA
LA
RECEPCIN
Incluye:
Pg. 68 de 78
Pg. 69 de 78
Mantenimiento correctivo
El mantenimiento correctivo a cargo del proveedor consistir en la reparacin de todas las fallas de equipo
y/o sistema, para su correcto funcionamiento. Para cumplir con lo anterior, el proveedor deber contar con
los recursos materiales y humanos necesarios para que en este perodo se tenga disponibilidad para asistir a
atender las fallas presentadas en cualquier da de la semana, las 24 horas del da, los 365 das del ao.
Para garantizar la eficiencia de estos trabajos, el personal del proveedor responsable del mantenimiento
deber proporcionar una forma de comunicacin rpida y directa con l, para la atencin de las averas que
puedan ocurrir, con el objeto de facilitar su localizacin.
El seguimiento a lo anterior, ser de la siguiente manera:
Al presentarse la falla en uno de los equipos del sistema suministrado, el encargado del mantenimiento de los
equipos y/o sistema por parte del S.T.C., se comunicar va telefnica con la persona responsable del
mantenimiento en la Ciudad de Mxico, describindole a ste las caractersticas de la falla con el propsito
Pg. 70 de 78
Pg. 71 de 78
Suministro de los gabinetes, repartidores, conectores, pig-tails, patch-cords, etc necesarios para
implementar todas las conexiones necesarias para la implementacin de la Red Multiservicio (segn
la topologa definida por el licitante), teniendo en cuenta que todas las fibras (incluyendo las no
utilizadas), sern conectorizadas en todas las estaciones.
Electrnica de Red
Suministro, tendido y conexionado de los latiguillos de F.O. necesarios para interconectar los
equipos suministrados, segn la topologa definida por el licitante.
Pg. 72 de 78
Todos los equipos de la solucion debern ser de la misma marca para evitar incopatibilidad e
inoperatividad de los mismos.
rea I. la Catlica
222 Puntos de Red
rea Chabacano
132 Puntos de Red
rea Delicias
263 Puntos de Red
rea Juarez
333 Puntos de Red
rea Balbuena
85 Puntos de Red
rea Sevilla
98 Puntos de Red
rea Cuauhtemoc (y policlnica) 306 Puntos de Red
rea Revolucin
250 Puntos de Red
rea Guelatao
76 Puntos de Red
rea Salto del Agua
279 Puntos de Red
Ingeniera Desarrollo/ INCADE 250 Puntos de Red
rea Zapata
40 Puntos de Red (Estimado)
rea Guerrero
40 Puntos de Red (Estimado)
SEAT Oceana
40 Puntos de Red (Estimado)
SEAT Estrella
40 Puntos de Red (Estimado)
Pg. 73 de 78
Para la conexin del Sistema de Tarjeta sin contacto se deben suministrar 175 cables de cobre UTP de
aproximadamente 10 m. para la conexin del equipo Concentrador de Estacin de este sitema hacia el
Nodo de Acceso de la Red de Comunicaciones y Servicios.
Suministro de la canalizacin y los cables para la conexin de los sistemas de Sistema de
Videovigilancia y Sistema Integral de Alarmas
o 185 Subestaciones de Rectificacin (SRs)
Enlace con par de cobre categora mnima 5, para instalacin de alarmas y videovigilancia.
11.1. Topologa
La red de comunicaciones estar conformada por una Red Principal (backbone), con equipos clase
metropolitana en tecnologa plataforma de transporte multiservicios 10 Gigabit Ethernet, interconectados
entre s por medio de fibra ptica monomodo, en forma de anillo redundante, Redes de Distribucin por
Lnea, interconectadas en forma de rbol redundante por medio de fibra ptica monomodo a Gigabit
Ethernet, y un nivel de Red de Acceso por cada estacin o punto de importancia relacionado en los
objetivos; adems contar con todo el equipamiento necesario para proporcionar conexin a la aplicacin
de los diversos servicios, equipamiento como: cables de cobre (UTP) y paneles de parcheo.
Esto hace conveniente que el trfico de las estaciones se concentre por Lneas y alcance los Puestos de
Control en un nmero reducido de saltos.
Para ste propsito se desempear bajo una arquitectura jerrquica, con niveles y funciones claramente
definidos: Red Primaria (Ncleo, backbone), Red Secundaria (distribucin), Red de Acceso y Aplicacin.
Descritos a continuacin y mostrados en la figura 1.
Pg. 74 de 78
Estructura Jerrquica.
Pg. 75 de 78
11.1.2 Funciones
El anillo de Backbone o Red Principal de fibra ptica realizar la transferencia de informacin del Sistema
bajo tecnologa DWDM a 10 Gigabit en una plataforma metropolitana de transporte multiservicios IP; la
tecnologa de toda la Red de Comunicaciones, en sus tres niveles, debe ser la apropiada que suministre
servicios de transporte de voz, datos y video.
Los Nodos de Distribucin, realizaran la interconexin delos Nodos de Acceso de las estaciones y el enlace
hacia la Red Primaria. Los Nodos de Acceso, en la Red de Distribucin fungirn como puesto de enlace en
las estaciones, proporcionando el punto de conexin a las Redes de Acceso.
El parmetro principal de diseo es la alta disponibilidad de la red. Es preciso que todos los equipos
dispongan de redundancia a nivel de enlaces, descartando la existencia de un punto de fallo en la red.
Pg. 76 de 78
Red de Acceso, sta conexin emplear equipos satlites (Nodo de Red Local) en una arquitectura de
estrella, fungir como puente conectando los nodos secundarios a los sistemas o redes locales. Existir un
equipo de acceso por cada sitio en que sea requerido el enlace de alguna aplicacin, si sta conexin est
ubicada fuera de la estacin (edificio administrativo, garage, etc.). Adems se incluir un equipo de acceso
en los casos en los que por el nmero de interfaces necesarios, por la naturaleza de la aplicacin o por la
ubicacin fsica de los usuarios, sea necesario incluir nodos adicionales.
Pg. 77 de 78
Pg. 78 de 78
1) Red Multiservicio
de S.T.C.
ANEXO TCNICO
Pg. 1 de 78
INTRODUCCIN.......................................................................................................................................................................... 4
2.
OBJETIVOS .................................................................................................................................................................................. 4
3.
ARQUITECTURA DE LA SOLUCIN...................................................................................................................................... 5
3.1.
INFRAESTRUCTURA DE FIBRA PTICA ............................................................................................................................6
3.2.
ELECTRNICA DE RED ........................................................................................................................................................7
3.3.
GESTIN DEL TRFICO DE RED.........................................................................................................................................9
3.3.1. Gestin de Trfico a Nivel 2......................................................................................................................................10
3.3.2. Gestin de Trfico a Nivel 3......................................................................................................................................10
3.3.3. Calidad de Servicio ....................................................................................................................................................11
3.3.4. Transporte de Canales Sncronos............................................................................................................................12
3.4.
SISTEMAS DE GESTIN DE RED .......................................................................................................................................12
4.
5.
CONDICIONES DE INSTALACIN.......................................................................................................................................46
5.1.
5.2.
5.3.
5.4.
6.
DOCUMENTACIN...................................................................................................................................................................58
6.1.
DOCUMENTACIN TCNICO-ECONMICA ............................................................................................................58
6.2.
DOCUMENTACIN DE ESTUDIOS ..............................................................................................................................59
6.3.
3. DOCUMENTACIN DE OPERACIN Y MANTENIMIENTO..............................................................................61
3.6.1. Documentacin preliminar .......................................................................................................................................62
3.6.2. Documentacin definitiva .........................................................................................................................................62
7.
8.
CAPACITACIN........................................................................................................................................................................63
Pg. 2 de 78
CONDICIONES DE LA GARANTA...............................................................................................................................65
PROLONGACIN DE LA GARANTA ..........................................................................................................................66
VICIOS OCULTOS .............................................................................................................................................................67
CONSIDERACIONES HASTA LA RECEPCIN PROVISIONAL..............................................................................67
MANTENIMIENTO PREVENTIVO Y CORRECTIVO DURANTE LA GARANTA ...............................................68
10.
11.
11.1.
TOPOLOGA .........................................................................................................................................................................72
11.1.1
Estructura Jerrquica...........................................................................................................................................73
11.1.2
Funciones ................................................................................................................................................................74
Pg. 3 de 78
1. INTRODUCCIN
La red de servicio del Sistema de Transporte Colectivo (S.T.C.) esta integrada por 175 estaciones, 7
talleres y varias reas administrativas, prestandose en todas estas ubicaciones diferentes servicios.
Esta dispersin geogrfica de ubicaciones, y por tanto de servicios, y la futura implantacin de servicios
centralizados (como Video-Vigilancia, Video-Audimetro, Alarmas, etc) hace que sea necesario contar
con una infraestructura de comunicaciones que permita interconectar todos estos elementos entre s, de
forma que se puedan prestar los servicios de forma remota e integrada.
El presente documento define los objetivos y requisitos con los que deber contar la Nueva Red de
Comunicaciones Multiservicio de S.T.C.
2. OBJETIVOS
El objetivo de la Red de Comunicaciones Multiservicio del STC es permitir interconectar las diferentes
ubicaciones entre s, a travs de un soporte de transmisin nico de alta capacidad, que permita la
transmisin de datos, voz y video.
Solucion IP de extremo a extremo escalable que permita la convergencia de todo tipo de trfico (voz,
video, datos,etc.) sobre la misma estructura y equipos, utilizando tecnologa estandar con QoS y QoE
apropiadas para todos los usuarios.
En concreto se integrarn dentro del alcance del presente proyecto:
Talleres Zaragoza
Talleres Tasquea
Talleres Ticomn Indios Verdes
Talleres El Rosario
Talleres Constitucin
Talleres La Paz
Talleres Ciudad Azteca
Pg. 4 de 78
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
rea I. la Catlica
rea Chabacano
rea Delicias
rea Juarez
rea Balbuena
rea Sevilla
rea Cuauhtemoc
rea Revolucin
rea Guelatao
rea Salto del Agua
rea Ingeniera Desarrollo de Nuevos Proyectos/ INCADE
rea Zapata
rea Guerrero
SEAT Oceana
SEAT Estrella
Deber ser construida para integrar los servicios actuales y prever la integracin de servicios futuros, por lo
que deber una solucin ampliable y responder a criterios de mxima modularidad.
Entre los servicios que se conectarn a la Red de Comunicaciones Multiservicio estarn:
Video-vigilancia
Sistema de Tarjeta Sin Contacto (Tarjeta Inteligente)
Redes LAN
Video-Audiometro.
Sistemas Integral de alarmas
Sistema de Telefona IP
Control de asistencia y horarios
etc
Dado lo crtico de los servicios a prestar sobre la Red de Comunicaciones Multiservicio, tanto el diseo
topolgico de la red, como el equipamiento elegido debern proporcionar el mximo nivel de fiabilidad
posible.
Dado que la mayor parte de los servicios previstos se basarn en el protocolo TCP/IP, la solucin de red
propuesta deber estar optimizada para este tipo de trfico, aunque debe permitir tambin el transporte de
canales sncronos (tipo serie, E1/T1, STM-1/OC-3 ,etc).
Pg. 5 de 78
3. ARQUITECTURA DE LA SOLUCIN
La Red de Comunicaciones propuesta debera integrar
Los servicios de explotacin, se operan mayoritariamente por lneas, con un puesto de control central. Esto
hace que la mayor parte del trfico vaya a mantenerse dentro de la misma lnea en la que se gener, o se
concentre en ciertos puntos centrales determinados.
La topologa de red a implementar, deber tener en cuenta estos flujos de trfico mayoritarios, y optimizarse
teniendolos en cuenta.
La Topologa propuesta deber mantener una estructura jerarquica, redundante, con una distribucin
basada en lneas.
La interconexin entre los diferentes nodos se realizar a travs de fibra ptica implementando conexiones
de alta capacidad (10 Gb como mnimo) redundadas, de forma que cada nodo cuente con al menos 2
conexiones que permitan mantener el servicio ante la caida de cualquier otro equipo o enlace.
La topologa exacta, en cuanto a nmero de Nodos de Distribucin y Troncal, as como su ubicacin, se
dejan a criterio del licitador, que deber proponer la mejor solucin desde el punto de vista tcnico y
econmico, intentando minimizar en todo momento el uso de recursos de interconexin (fibra ptica) y el
nmero de saltos para alcanzar el Puesto Central y maximizando el rendimiento de transporte de la red en
funcin de los flujos de trfico esperados.
Pg. 6 de 78
Nodos Principales
Nodos de Distribucin
Nodos de Acceso
Nodos de Red Local
Los Nodos Principales son los encargados de interconectar el trfico de todas las lneas entre s y hacia los
Puestos Centrales de Control, para lo cual se requieren equipos pticos multiplataforma de servicios de alta
velocidad en el plano de transporte, que proporcionen ancho de banda de 10 GE con posibilidad de escalar
a 320 GE, preparados para la convergencia de los sitemas de comunicacin (recomendacin ITU-T H.323)
y crear una red NGN.
La Recomendacin ITU-T Y.2001 (ITU-T H.323) expone entre sus caractersticas ms relevantes: el uso
de tecnologa de conmutacin de paquetes IP/MPLS en el plano de transporte y la separacin entre las
funciones relacionadas con el servicio y las tecnologas de transporte. Esta divisin es importante porque
permite que los servicios trabajen sin el conocimiento de la tecnologa de red y el acceso con absoluta
rapidez al plano de trasporte, pudiendo evolucionar cada uno de forma independiente. Similarmente,
permite la migracin desde las redes actuales, verticalmente separadas y especficas para diferentes
servicios, hacia una nica red capaz de ofrecer y transportar todos los servicios.
Debern ser equipos modulares de al menos 12 slots, redundados en todos sus elementos fundamentales
(fuentes de alimentacin, tarjeta procesadora, etc) y con una muy alta capacidad de gestin de trfico tanto
a nivel 2 (switching) como a Nivel 3 (routing) incluyendo protocolos de routing dinmico (RIP, OSPF,
IGRP, IS-IS, BGP, etc) y un completo soporte de Multicast.
Pg. 7 de 78
Cada Nodo Principal contar con al menos 2 interfaces pticas a 10 Gigabit Ethernet Configurables
mediante mdulos XENPAK/XFP y 14 interfaces 1 Gigabit Ethernet de alcance configurable mediante
mdulos GBIC o SFP, deberan presentar la posibilidad escalar a interfaces pticas a 10 Gigabit Ethernet
Configurables mediante mdulos XENPAK/XFP y 8 interfaces 10/100/1000BaseT para conexin de
posibles servicios locales.
El equipo contar con una amplia capacidad de crecimiento, manteniendo libres al menos el 30% de los
slots destinados a tarjetas de interfaces.
Los Nodos de Distribucin concentran el trfico procedente de los Nodos de Acceso y lo distribuyen a
los distinitos niveles de la topologa de red. Contarn con al menos 8 interfaces pticas Gigabit Ethernet de
alcance configurable mediante mdulos GBIC o SFP y deberan presentar la posibilidad escalar a interfaces
pticas a 10 Gigabit Ethernet Configurables mediante mdulos XENPAK/XFP
Los Nodos de Distribucin contarn con una alta capacidad de gestin de trfico, tanto a Nivel 2, como a
Nivel 3, incluyendo protoclos de routing dinmico (RIP, OSPF, IGRP, etc) y un completo soporte de
Multicast.
Los Nodos de Distribucin debern permitir una ampia capacidad de crecimiento por lo que debern ser
equipos modulares o apilables, tambien deben ser aptos para la NGN.
Los Nodos de Acceso sern los nodos que se instalarn en cada una de las ubicaciones (estaciones,
talleres y reas administrativas) y a ellos se enlazarn los equipos que compondrn los servicios de
explotacin.
Existirn diversos tipos de Nodo de Acceso en funcin de la complejidad del recinto al que dar servicio.
Se contemplan 3 tipos de Nodos de Acceso:
Pg. 8 de 78
Pg. 9 de 78
3.3.1.
Pg. 10 de 78
3.3.2.
Los Nodos de Red Principal, Distribucin y Acceso contarn con la capacidad de gestin trfico a nivel 3
(routing) incluyendo el soporte de protocolos estndar de routing dinmico.
El licitante deber realizar una propuesta de filosofa de direccionamiento IP y una propuesta de solucin de
routing acorde con el direccionamiento IP que defina. Evidentemente, al no poroporcionarse datos
concretos sobre los servicios, dicha propuesta no podr ser completa, pero deber reflejar la filosofa de
diseo de solucin propuesta, incluyendo al menos:
El diseo deber contemplar caminos alternativos que permitan mantener el servicio ante la caida de
cualquier equipo.
Se optimizar la convergencia de los cminos alternativos, as como el reclculo de rutas ante
situaciones de indisponibilidad de algn nodo.
Deber existir un control de trfico generado en cada estacin y que tenga como destino la misma
estacin, para que se propage a travs de la Red de Distribucin y Principal.
Se optimizarn las rutas de acceso a los Nodos Principales y Centros de Control
3.3.3.
Calidad de Servicio
La solucin de red propuesta deber contar con amplias capacidades de Calidad de Servicio (QoS) que
permitan diferenciar y clasificar el trfico circulante por la red priorizando los flujos ms estratgicos o
importantes.
Los equipos debern contar con mecanismos para
Pg. 11 de 78
3.3.4.
Aunque dentro del alcance previsto para el presente proyecto no se prev que sea necesario implementar
ninguna conexin de tipo sncrono, la red deber estar preparada para poder transportar canales sncronos
de tipo PDH (E1/T1) o SDH/SONET (hasta STM-1).
Este transporte podr ser tipo TDM (Time Division Multiplex) nativo, o emulado a travs de soluciones
estandarizadas (CESoPSN, SAToP, TDMoIP, etc).
Aunque no se incluira dentro del alcance del proyecto, el licitante deber explicar la solucin propuesta para
realizar este tipo de transporte, incluyendo una propuesta de hardware necesario para por lo menos el
transporte de canales tipo E1/T1.
El Software de Gestin de Proposito General sera un gestor SNMP en su version ms reciente, que permita
monitorear, no slo los elelemntos de red, sino tambin cualquier otro elementos compatible SNMP.
Pg. 12 de 78
4. CARCTERISTICAS
TCNICAS
EQUIPAMIENTO Y MATERIALES
DE
A continuacin se incluyen las caractersticas mnimas que debern cumplir los equipos y materiales
empleados en el presente proyecto
Pg. 13 de 78
Interfaz de acoplamiento
1.4.1.
Pg. 14 de 78
1.4.2.
Caractersticas
Menor de 15 mm 22.6
Menor de 250 kg/km 460
Minimo 1500 N
Mnimo 2000 N
220 mm
-30C +70C
De la Fibra
La fibra ptica a utilizar debe cumplir con la norma internacional ITU-T G.652.D. para transmitir
informacin en todo el espectro de longitud de onda de 1280 a 1625 nm que incluye las longitudes de
banda 1310 y 1550 nm.
1300 1322 m
0.092ps/m2-Km
Pg. 15 de 78
Atenuacin
1310
0.4 dB/km
1383
valor a 1300nm
1550
0.3 dB/km
1625
0.4 dB/km
Nmero de
vueltas
32
1550
60
100
1310
60
100
1550
60
100
1550
60
100
Longitud de
Onda (m)
Atenuacin
Inducida
(dB)
0.05
1625
2.4.1.
Pg. 16 de 78
2.4.2.
Caractersticas
Menor de 10 mm
Menor de 120 kg/km
Minimo 800 N
Mnimo 2500 N
120 mm
-30C +70C
De la Fibra
La fibra ptica a utilizar deber estar preparada para funcionar en las bandas de 850 y 1300 nanometros,
permitiendo su uso con todo tipo de conexiones, desde 10 Mbps hasta 10Gb.
Coeficiente de Atenuacin:
A 850 nanmetros 2,3 dB/Km.
A 1300 nanmetros 0,6 dB/km.
Apertura Numrica
Apertura Numrica
0,2 0,015
Dispersin Cromtica:
Longitud de Onda con cero dispersin
Pendiente de dispersin cromtica
1297 1316 m
0.101 ps/m2-Km
Pg. 17 de 78
ANSI/TIA/EIA-568-B.2-1 Categora 6
Las caractersticas mnimas de los elementos empleados para el Cableado de Pares sern las siguientes:
Cableado Horizontal
Cable de 4 pares, certificado Categora 6
Conductores de cobre slido AWG- 23
Cumpliendo con los estndares
ANSI/TIA/EIA-568-B.2-1 Categora 6
UL Listed.
Cableado Vertical
Cable de 4 pares, certificado Categora 6
Conductores de cobre slido AWG- 23
Cumpliendo con los estndares
ANSI/TIA/EIA-568-B.2-1 Categora 6
Pg. 18 de 78
UL Listed.
Tomas de Usuario
Roseta Modular de pared formada por un Face Plate doble y 2 conectores encastrables tipo RJ-45
hembra, cumpliendo con la siguiente normativa:
ANSI/TIA/EIA-568-B.2-1 Category 6 component compliant to the latest draft (9b)
IEEE 802.3ab Gigabit Ethernet verified
ETL Tested for Category 6 channel performance
UL Listed 1863
CSA Certified
FCC part 68.5, subpart F compliant
IEC-603-7 compliant
ISO 11801 Class E compliant
Repartidores (Patch-Pannel)
Paneles repartidores de 24 o 48 interfaces RJ-45.
Enracables en armarios de 19
cumpliendo con la siguiente normativa:
ANSI/TIA/EIA-568-B.2-1 Category 6 component compliant to the latest draft (9b)
IEEE 802.3ab Gigabit Ethernet verified
ETL Tested for Category 6 channel performance
UL Listed 1863
CSA Certified
FCC part 68.5, subpart F compliant
IEC-603-7 compliant
ISO 11801 Class E compliant
Certificado de laboratorio para soportar IEEE 802.3af DTE POWER
Pg. 19 de 78
ANSI/TIA/EIA-568-B.2-1 Category 6
UL Listed 1863
CSA Certified
IEC-603-7 compliant
Patch cord
ANSI/TIA/EIA-568-B.2-1 Category 6
UL Listed 1863
CSA Certified
IEC-603-7 compliant
Administradores Horizontales
Lamina de hacero 16 ga
2 unidad de rack
Pg. 20 de 78
Aplicaciones:
En el interior de locales con ambiente seco, hmedo o aceite, en conduit, ductos o charolas.
Tensin Mxima de Operacin:
600 V
Sobrecarga
Cortocircuito
105 C
150 C
Propiedades:
Pg. 21 de 78
Para permitir crecer de una forma modular, sin interferir con los elementos instalados previamente, la
interconexin a las fibras alojadas dentro de los paneles se realiar a travs de su parte delantera, mediante
frontales equipados con los conectores adecuados.
Para el presente proyecto se emplearn preferiblemente conectores SC o LC/PC para la fibra ptica
monomodo y LC o MT-RJ para la multimodo.
Cada panel contar con un frontal de al menos 36 conectores.
4.6. Gabinete
Repartidores
para
Ubicacin
de
Equipos
El gabinete para ubicacin de equipos y repartidores de cableado ser metlico, con puerta transparente
resistente a golpes.
Sus principales caractersticas
Como armarios repartidores secundarios en edificios administrativos o talleres, podrn emplearse gabinetes
murales de 3 pies, con las mismas caractersticas fisicas.
Pg. 22 de 78
Pg. 23 de 78
Debern presentar la posibilidad de ser montados en rack de 19, al interior de armarios estndar
de 23.
Doble fuente de Alimentacin, con posibilidad de alimentacin en corriente alterna o continua.
Sistema de refrigeracin con ventiladores independientes
Soporte de PoE (Power over Ethernet) IEEE 802.3af integrado en el chasis (sin necesidad de
mdulos de alimentacin externos)
Posibilidad de integrar en el chasis tarjetas de los siguientes tipos de interfaces con las siguientes
cantidades mnimas
o Fast Ethernet 10/100BaseT (RJ-45) 240 Puertos
o Fast Ethernet 10/100BaseT (R-45) con PoE (Power over Ethernet) compatible IEEE
802.3af 240 Puertos
o Fast Ethernt sobre Fibra ptica (100BaseFX / 100BaseLX) 240 Puertos
o Gigabit Ethernet Configurables mediante mdulos GBIC/SFP 244 Puertos
o 10 Gigabit Ethernet Configurables
o 10/100/1000BaseT (RJ-45) 240 puertos
o 10/100/1000BaseT (RJ-45) con soporte PoE compatible IEEE 802.3af 240 puertos
Soporte DWDM para la implementacin de varias conexiones 10 Gigabit sobre un mismo par de
fibras pticas
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
o IEEE 802.3, 100BASE-FX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
10 Gigabit Ethernet
o IEEE 802.3ae
o IEEE 802.3x
Pg. 24 de 78
IEEE 802.3aq
10GBASE-SR
10GBASE-LR
10GBASE-ER
10GBASE-ZX
Seguridad
o IEEE 802.1x
Rendimiento
Topologias soportadas
Punto a punto, add/drop lineal, anillo, estrella y malla.
Multianillo con soporte de cierre mnimo de 5 anillos en el mismo sistema y esquema de anillo de proteccin
para 2 4 fibras.
Funcionalidades de Nivel 2
Pg. 25 de 78
Soporte de Spanning Tree por VLAN (PVST+) y Rapid Spanning Tree por VLAN (PVRST)
Soporte IGMP (Internet Group Management Protocol) snooping v1, v2, v3
Soporte 802.1s, 802.1w, 802.1ad
Soporte de Jumbo Frames
Soporte de Agregacin de Canales Ethernet, Fast Ethernet o Gigabit Ethernet.
Funcionalidades de Nivel 3
Calidad de Servicio
Seguridad y Gestin
Pg. 26 de 78
o 802.1x accounting
o 802.1x authentication failure
o 802. 1x Private VLAN assignment
o 802. 1x Private Guest VLAN
o 802. 1x Radius-supplied time out
Soporte de ACLs (Access Control List) por puerto y VLAN
Soporte de DHCP.
Soporte de SSHv1 y SSHv2.
Filtrado MAC unicast.
Inspeccin dinmica ARP
Filtado por direccin MAC Unicast
Compatible SNMP v1, v2, v3.
Telnet.
TFTP (Trivial File Transfer Protocol).
RMON (Remote Monitoring).
RSPAN (Remote Switched Port Analyzer):
o Filtrado SPAN ACL
o Autoconfiguracin DHCP (Dynamic Host Configuration Protocol).
o Soporte de Enhanced SNMP MIB.
Pg. 27 de 78
Soporte DWDM para la implementacin de varias conexiones sobre un mismo par de fibras pticas.
En caso de optar por soluciones apilables, la configuracin de los equipos apilados deber ser conjunta,
como si fueran un nico equipo fsico, manteniendose todas las caractersticas definidas en todos y cada uno
de los equipos que forman la pila.
Debern presentar la posibilidad de ser montados en rack de 19, al interior de armarios estndar de 23.
Protoclos de Red Soportados
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
10 Gigabit Ethernet
o IEEE 802.3ae
o IEEE 802.3x
o IEEE 802.3aq
o 10GBASE-SR
o 10GBASE-LR
o 10GBASE-ER
o 10GBASE-ZX
VLAN trunking y tagging
o IEEE 802.1Q
o IEEE 802.3ad
Pg. 28 de 78
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Funcionalidades de Nivel 3
Pg. 29 de 78
Seguridad y Gestin
Pg. 30 de 78
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
o IEEE 802.1Q
o IEEE 802.3ad
Pg. 31 de 78
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Funcionalidades de Nivel 3
Pg. 32 de 78
Calidad de Servicio
Seguridad y Gestin
Pg. 33 de 78
4.10. Nodo
de
Acceso
para
Correspondencia de Lneas
Estacin
Con
Los Nodos de Acceso son los encargados de propocionar la conectividad a los usuarios y servicios.
En el caso de Estaciones con Correspondencia de Lneas, o reas de Edificios Administrativos Estandar,
contarn con al menos 4 interfaces Gigabit Ethernet configurables en alcance mediante mdulos GBIC o
SFP y 48 interfaces 10/100BaseT. Con capacidad de gestin de trfico tanto a nivel 2 (switching/bridging)
como a nivel 3 (routing).
Sus caractersticas mnimas debern ser:
Capacidad del Hardware
Soporte DWDM para la implementacin de varias conexiones sobre un mismo par de fibras pticas.
Doble fuente de Alimentacin, con posibilidad de alimentacin en corriente alterna o continua.
48 Interfaces 10/100/1000BaseT para acceso de usuarios y servicios, 4 Puertos Gigabit configurables en
alcance mediante mdulos GBIC o SFP para interconexin con otros nodos.
Debern presentar la posibilidad de ser montados en rack de 19, al interior de armarios estndar de 23.
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
Pg. 34 de 78
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
o IEEE 802.1Q
o IEEE 802.3ad
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Pg. 35 de 78
Funcionalidades de Nivel 3
Calidad de Servicio
Seguridad y Gestin
Pg. 36 de 78
Pg. 37 de 78
Soporte DWDM para la implementacin de varias conexiones Gigabit sobre un mismo par de fibras
pticas
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
Pg. 38 de 78
10 Gigabit Ethernet
o IEEE 802.3ae
o IEEE 802.3x
o IEEE 802.3aq
o 10GBASE-SR
o 10GBASE-LR
o 10GBASE-ER
o 10GBASE-ZX
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Pg. 39 de 78
Funcionalidades de Nivel 3
Calidad de Servicio
Seguridad y Gestin
Pg. 40 de 78
Pg. 41 de 78
Ethernet
o IEEE 802.3, 10BASE-T
Fast Ethernet
o IEEE 802.3u, 100BASE-TX
Gigabit Ethernet
o IEEE 802.3z
o IEEE 802.3x
o IEEE 802.3ab
o 1000BASE-T
o 1000BASE-SX
o 1000BASE-LX/LH
o 1000BASE-ZX
Seguridad
o IEEE 802.1x
Rendimiento
Funcionalidades de Nivel 2
Pg. 42 de 78
Calidad de Servicio
Seguridad y Gestin
Deber componerse de dos subsistemas independientes, con la capacidad de integrarse en uno slo.
Descubrimiento de Redes
Deteccin de Problemas
Mediante una serie de procesos en background (que no necesitan actuacin por parte del
opoerador del sistema) el sistema ser capaz de descubrir todos los equipos conectados en la
red as como las posibles conexiones con otras redes diferentes redes
A travs de las tablas de rutas de los elementos deber ser capaz de crear un mapa topolgico
en el que aparezcan los nodos de la red con sus interconexiones.
Deteccin de Problemas
Pg. 44 de 78
Las alarmas sern categorizas segn su nivel crtico. Este nivel crtico deber ser definido por el
administrador del sistema.
Cualquier problema o evento detectado ser almacenado en un log, o base de datos abierta,
que permita su consulta y tratamiento a posteriori
Consola de Operacin
La operacin del software de Gestin de Red se realizar a travs de una consola grfica de facil
manejo, accesible de forma remota , con un sistema de control de acceso y validacin por usuario y
password.
Esta consola permitira gestionar la infraestructura instalada a trves de planos topolgicos, mediante el
uso de cdigos de colores.
La visualizacin de la topologa de red se deber poder realziar a diferentes niveles, siendo obligatorio
poder contar con como mnimo 5 niveles o mapas, que permitan tener vistas del estado de la red en al
menos los siguientes modos:
Pg. 45 de 78
Funcionamiento normal
Con avisos (warnings) que no afectan a su normal funcionamiento
Con errores que limitan alguna capacidad
Estado de No disponible
Permitir realizar una gestin de MIB (Management Information Base) que incluya, como mnimo la
carga, descarga y actualizacin de MIBs propietarias de los equipos instalados
Permitir la generacin de informes de inventario, rendimiento y alarmas
Inventario detallado tanto software como hardware de todo el equipamiento de red , incluyendo:
o Versiones de software
o Mdulos
o Tarjetas
o Configuraciones
Captura mensajes generados en la consola de cada nodo de una forma remota y desatendida
(Syslog Analysis).
Actualizacin de Sistema Operativo desatendidamente y de una forma planificada.
Monitorizacin de la accesibilidad y el tiempo de respuesta de los dispositivos de red.
Control de cada cambio hardware de cada dispositivo.
Control del histrico de Configuraciones de cada dispositivo, permitiendo comparar distintas
versiones.
Modificacin, borrado e incorporacin de nuevos configuraciones de una forma desatendida y
programada.
Diseo de un mapa de todos los nodos instalados permitiendo filtrar por VLAN, dominios VTP,
etc.
Creacin, modificacin y borrado de VLANs de varios de equipos de la red a la vez.
Pg. 46 de 78
Control de todos los equipos conectados a cada puerto del equipamiento. (Direccin MAC,
Direccin IP, Nombre del equipo, Usuario Conectado, etc.).
Visualizacin grfica de cada dispositivo mostrando una representacin real (tal y como es
fsicamente el equipo) con el estado en tiempo real de los mdulos, interfaces, etc.
Plataforma Hardware
Las 2 aplicaciones que integran la Plataforma de Gestin de Red debern instalarse sobre una misma
plataforma hardware.
Las caractersticas, a nivel de rendimiento (CPU, memora, disco duro, etc) de la Plataforma Hardware
debern superar de forma holgada los requerimientos definidos por los fabricantes de las aplicaciones.
Deber ser una plataforma de alta disponibilidad, que cuente con:
5. Condiciones de Instalacin
Todas las instalaciones, conexionados y tendidos de cable se realizarn conforme a las normativas
mexicanas vigentes y a los procedimientos definidos por el S.T.C. asi como los horarios prestablecidos para
estos trabajos.
A continuacin se incluyen los criterios bsicos de instalacin definidos para el presente proyecto.
Los horarios de trabajo podrn ser realizados acorde a la siguiente tabla:
Lugar
Centro Estratgico de Operaciones
Horario permitido de
Lunes a Viernes hbiles
24 hrs
Actividad a realizar
Instalacin de equipos
Estaciones
Andenes y zona de vas
Locales Tcnicos
Tendido e instalacion de
bandeja de rejilla y cable de
fibra ptica
24 hrs
Instalacin, conexionado de
equipos, armarios, fibra y
distribuidores pticos
Pg. 47 de 78
Instalacin de cableado
estructurado
Pg. 48 de 78
Pg. 49 de 78
Pg. 50 de 78
Cajas Registro
Serie Rectangular, para reas no peligrosas y a la intemperie.
Material: Aluminio libre de cobre
Acabado: Pintura electrosttica.
Tipos: FS, FSC, FSCC, FSCD, FSX
Tapas: Tapa ciega para caja registro serie rectangular tipo FS.
Pg. 51 de 78
La cantidad de cables y espacio a ocupar en los tubos ser de acuerdo a lo indicado en la norma oficial
mexicana NOM-001-SEMMP-1994.
No se deben colocar dos o ms tubos para una misma ruta y tipo de cableado. En su lugar se utilizar
un solo tubo de mayor dimetro, salvo los casos que permita la norma antes mencionada, que el
dimetro requerido rebase las 2 o bien que se trate de una seal con potencial para alimentacin, la
cual debe ir en forma independiente a las seales de datos y control.
Pg. 52 de 78
Tuberas
Ductos
Charolas
En general, cualquiera que sea el tipo de canalizacin que se emplee debe cumplir con los siguientes puntos:
Los conductores no deben introducirse en las canalizaciones sino hasta que estas hayan sido instaladas y
formen un sistema completo con todos sus accesorios.
Si se usan guas para introducir los conductores, estas debern insertarse hasta que las canalizaciones estn
instaladas en su lugar.
Para introducir los conductores no deben utilizarse lubricantes que puedan daar el aislamiento de dichos
conductores.
Cuando un tubo o ducto entre a una caja, gabinete o accesorio, debe colocarse una boquilla que evite
raspaduras en el aislamiento o cubierta de los conductores, a menos que la construccin propia del
accesorio ofrezca una proteccin equivalente.
El doblado del tubo o ducto debe hacerse con las tcnicas y herramientas adecuadas, de manera que no se
produzcan grietas y que su dimetro interior no se reduzca ms del 10%. El radio de curva interior, en el
caso de dobleces, no debe ser menor a 10 veces el dimetro exterior del tubo.
En un tramo de tubera entre dos cajas de conexin consecutivas, entre una caja y un accesorio o entre dos
accesorios no deben existir ms de dos curvas de 90 grados o su equivalente (180 grados en total),
incluyendo las curvas inmediatas a las cajas o accesorios. En su lugar se utilizarn los condulets apropiados
para cada caso, con el fin de permitir un alambrado fcil por el tubo.
En tubos y ductos cerrados, sin tapa, los conductores deben ser fsicamente continuos (sin empalmes) entre
dos cajas o entre dos accesorios consecutivos.
Debe instalarse una caja de conexiones en cada punto de empalme o derivacin de conductores o en cada
punto de interrupcin o punto de confluencia de la canalizacin, cuando la instalacin cambie de un tipo de
canalizacin a otro.
No se requieren registros para hacer derivaciones de conductores en canalizaciones que tengan tapas
removibles, tales como ductos con tapa, condulets o charolas.
El nmero mximo de conductores en una canalizacin debe respetar los factores de relleno especificados
en cada caso.
Pg. 53 de 78
Tuberas
Se utilizarn los siguientes tipos:
a) Tubo conduit metlico
b) Tubo metlico flexible
c) Tubo no metlico
A.
Su utilizacin ser general exceptundose aquellos lugares en donde se deben cruzar vas energizadas o
cuando la superficie donde sern colocadas sea muy irregular.
La seccin transversal del tubo debe ser circular.
Pg. 54 de 78
Cajas Registro
Serie Rectangular, para reas no peligrosas y a la intemperie.
Material: Aluminio libre de cobre
Acabado: Pintura electrosttica.
Tipos: FS, FSC, FSCC, FSCD, FSX
Tapas: Tapa ciega para caja registro serie rectangular tipo FS.
Empaques:
Empaque cerrado de neopreno para caja registro serie rectangular tipo FS.
Asimismo debern emplearse tapones de cierre PLG y reducciones RB a prueba de polvos,
combustible y lluvia.
La tubera debe fijarse firmemente, cuando menos cada 1.50 metros y a no ms de 75 cm de cada caja,
gabinete o accesorio, utilizando para ello abrazaderas o accesorios que no daen el tubo y que cumplan
con las siguientes caractersticas:
La cantidad de cables y espacio a ocupar en los tubos ser de acuerdo a lo indicado en la norma oficial
mexicana NOM-001-SEMMP-1994.
Pg. 55 de 78
No se deben colocar dos o ms tubos para una misma ruta y tipo de cableado. En su lugar se utilizar
un solo tubo de mayor dimetro, salvo los casos que permita la norma antes mencionada, que el
dimetro requerido rebase las 2 o bien que se trate de una seal con potencial para alimentacin, la
cual debe ir en forma independiente a las seales de datos y control.
B.
Dentro de esta designacin tenemos el tubo flexible sin forro y con forro, hecho de cinta metlica
engargolada (en forma helicoidal), el cual deber cumplir con las siguientes caractersticas:
Tubo flexible sin forro.
Tubo metlico flexible, engatillado simple, fabricado con fleje de acero galvanizado por
ambas caras.
Caractersticas del fleje: acabado mate, bordes cizallados sin galvanizar, recubrimiento de
zinc.
Temperatura mxima de uso: 300 C
Tubo metlico flexible, engatillado simple, fabricado con fleje de acero galvanizado con
una funda plstica autoextinguible adaptada a su contorno exterior para incrementar su
estanqueidad.
Caractersticas del fleje: acabado mate, bordes cizallados sin galvanizar, recubrimiento de
zinc.
Caractersticas del recubrimiento de PVC: Autoextinguible, color gris.
Temperatura mxima de uso: 70 C
Se utilizar en las entradas para los racks y gabinetes, es decir, para llevar los conductores desde
la canalizacin hasta los muebles de monitoreo o donde se resguardan los equipos de control.
Tambin podrn utilizarse en aquellos lugares en donde la superficie a la cual se fijar la
canalizacin sea muy irregular.
No deber usarse tubo metlico flexible de dimetro nominal inferior a 13 mm (1/2) ni superior a
51 mm (2).
El acoplamiento a cajas, ductos y gabinete deber hacerse usando los accesorios apropiados para este
objeto y que cumplan con lo siguiente:
Pg. 56 de 78
La cantidad de cables y espacio a ocupar en los tubos, ser de acuerdo a lo indicado en la norma
oficial mexicana NOM-001-SEMMP-1994.
No se deben colocar dos o ms tubos para una misma ruta y tipo de cableado. En su lugar se utilizar
un solo tubo de mayor dimetro, salvo los casos que permita la norma antes mencionada, que el
dimetro requerido rebase 51 mm (2), o bien que se trate de una seal con potencial para
alimentacin, la cual debe ir en forma independiente a las seales de datos y control.
C.-Tubo no metlico
La seccin transversal de este tubo debe ser circular y se utilizar nicamente cuando la instalacin
cruce vas energizadas o cuando la instalacin corra en forma paralela a las vas a menos de 2 metros de
separacin.
No deber utilizarse tubos no metlicos de dimetro nominal inferior a 13 mm (1/2) ni superior a 51
mm (2).
Los extremos de cada tubo deben quedar libres de bordes cortantes.
El material empleado para su construccin debe ser autoextinguible, resistente a la humedad, debe tener
suficiente resistencia mecnica para proporcionar adecuada proteccin a los cables y para soportar un
trato rudo durante su instalacin, por lo que el tipo de tubo que se utilice debe ser de uso rudo.
Todas las uniones entre tubos, tubos y cajas, tubos y accesorios o entre accesorios y cajas, deben
hacerse por mtodos y con los materiales adecuados para este tipo de instalacin.
Las cajas y accesorios que se empleen en las instalaciones con tubo no metlico deben ser del mismo
material que el tubo.
Cuando se empleen cajas metlicas con tubo no metlico, las cajas debern conectarse a tierra.
Las instalaciones con tubo no metlico deben fijarse a intervalos no mayores a 1.50 metros.
Adems, deben soportarse a no ms de 75 cm de cada caja, gabinete u otro extremo del tubo.
Ductos
Pg. 57 de 78
Charolas
Estos requisitos se aplican a las estructuras rgidas y continuas especialmente construidas para soportar
cables, tales como charolas, canales, escalerillas y estructuras similares.
En general, las charolas, canales y escalerillas ya se encuentran instalados en el S.T.C., por lo que no se
requiere de la instalacin de ellas.
Podrn utilizarse siempre y cuando exista espacio disponible en ellas y adems no corran por la misma
charola cables de alta tensin.
En recorridos que no sean horizontales o donde los cables no puedan mantenerse por s mismos sobre las
charolas, los cables deben sujetarse firmemente a los elementos transversales de la misma charola por
medio de cinchos.
Deben proveerse soportes para evitar esfuerzos en los cables cuando stos se deriven fuera de la charola
hacia cualquier tipo de canalizacin.
Alimentacin y Tierra Fsica de las Instalaciones
Pg. 58 de 78
La forma de alimentar y conectar a tierra fsica los equipos, ser de acuerdo a la norma oficial mexicana
NOM-001-SEMMP-1994; asimismo se dispondr de la alimentacin elctrica en los locales que se indican
a continuacin.
En el Local Tcnico nmero 2 en estaciones y en las Subestaciones de Alumbrado y Fuerza en garages y
talleres se dispondr de una alimentacin de 127 y 220 Vca + 10% a 60 Hz + 1 Hz, de la cabina
preferencial P, por lo cual el proveedor deber considerar un tablero, con las pastillas termomagnticas
necesarias para alimentar los equipos que instalar.
Este tablero servir para alimentar todos los equipos que se ubicarn en cada instalacin, por lo que dentro
de los alcances del proveedor, se incluye llevar esta alimentacin desde el Local Tcnico 2 hasta la
ubicacin fsica de los equipos.
6. Documentacin
Pg. 59 de 78
Programa detallado de realizacin del proyecto, indicando cada parte del sistema y su seguimiento, este
programa deber ser validado y aprobado por personal responsable por parte del S.T.C. A entregar
30 das naturales despus de la firma del contrato.
Proyecto de tuberas, cableado e instalacin por lnea. A entregar una semana antes del inicio de los
trabajos en la lnea afectada
Manual de instalacin y operacin general del SISTEMA que deber cubrir cuando menos los
siguientes aspectos:
Pg. 60 de 78
Manuales de instalacin y operacin particular de los equipos, que debern cubrir cuando menos los
siguientes aspectos:
a) Medidas de seguridad en la instalacin y operacin de los equipos.
b) Descripciones detalladas sobre la operacin y caractersticas particulares de cada uno de los
equipos, con sus mdulos, accesorios y controles respectivos.
c) Diagramas de principio a bloques sobre la operacin e instalacin de los equipos, con sus
mdulos, accesorios y controles respectivos.
d) Procedimientos de instalacin y configuracin de los equipos, con ejemplos de aplicaciones tpicas.
e) Instrucciones de operacin y/o programacin del software utilizado en el proyecto.
f) Gua para la localizacin de fallas y mantenimiento a primer nivel (intercambio de mdulos e
intervenciones menores en campo), el cual debe incluir las actividades de mantenimiento
preventivo y su periodicidad.
g) Especificaciones.
Esta documentacin deber entregarse antes de la finalizacin total del proyecto
Manuales de servicio de los equipos, que debern cubrir cuando menos los siguientes aspectos:
a) Medidas de seguridad en el momento de dar servicio a los equipos, mdulos, accesorios y
controles respectivos, incluyendo el tipo y caractersticas de los equipos requeridos para efectuar
el servicio.
b) Descripcin detallada de cada uno de los circuitos elctricos y electrnicos, incluyendo las fuentes
de alimentacin de los equipos y ajustes necesarios para calibrar la operacin ptima de stos.
Pg. 61 de 78
Cuaderno de pruebas que debern cubrir cuando menos los siguientes aspectos:
a) Un certificado de las pruebas de aceptacin en sitio, en donde se relacionen de manera global
todos los bienes solicitados, de acuerdo al proyecto de que se trate, indicndolos con su nombre,
marca y modelo, nmero de serie, la cantidad de elementos, el tipo de aceptacin y la fecha en
que se reciben.
b) Una relacin a detalle y por reas sobre la inspeccin fsica y pruebas funcionales practicadas a
cada uno de los equipos en donde se incluir el nmero de serie en cada uno de ellos.
c) Se debe incluir las hojas sobre los reportes de las pruebas en fbrica, as como aquellos registros
de las pruebas practicadas en campo, sobre estas ltimas, el personal del S.T.C. debe haber
firmado en dichas hojas, respecto a la validacin de las pruebas.
d) En el cuaderno se deben marcar las pruebas de tipo mecnico, elctrico que se deben practicar a
cada uno de los equipos, asimismo se deben describir los procedimientos de prueba a cumplir.
Esta documentacin deber entregarse para cada tipo de equipo una semana antes de las primeras
pruebas de aceptacin de equipo que se realicen de dicho equipo
Manual de operacin, el cual deber cubrir cuando menos los siguientes aspectos:
a) Los principios bsicos de los sistemas instalados.
b) La configuracin del SISTEMA, con la ubicacin de los equipos en las estaciones, talleres,
garajes y en los Centros de Monitoreo.
c) Los procedimientos para la operacin de cada uno de los equipos en donde se incluya el
procedimiento para la inicializacin, arranque y apagado de los mismos.
Esta documentacin deber entregarse antes de la finalizacin total del proyecto
Pg. 62 de 78
Este manual servir de base para el curso que debe impartir el proveedor al personal operativo.
El proveedor deber presentar el programa detallado de realizacin del proyecto y requerimientos a ms
tardar 30 das naturales despus de la firma del contrato para su aprobacin por parte del S.T.C.
Todos los documentos arriba indicados debern ser presentados al S.T.C. Para revisin y aprobacin en
los formatos y nmero de copias indicadas.
Para este proyecto el proveedor entregara planos que se ajustarn a las dimensionesde 0.91 metros
por 1.40 metros (dimensiones mximas), con pie de plano, cuyas caractersticas se darn
posteriormente a dicho proveedor. Los anteproyectos y proyectos ejecutivos debern tener la
autorizacin del S.T.C. y tambin debern presentar la memoria tcnica descriptiva de cada uno de
los planos para revisin y validacin del S.T.C.
3.6.1.
Documentacin preliminar
Es la documentacin de estudios previamente mencionada y total del sistema (planos, diagramas, manuales,
cuadernos, etc.) de montaje, instalacin, funcionamiento y mantenimiento de los equipos, esta informacin
dar constancia del cumplimiento de la presente especificacin.
La documentacin preliminar se utilizar como borrador para anotar las modificaciones que pudieran surgir
durante el montaje, instalacin, pruebas y puesta en servicio del sistema de vdeo vigilancia. Esta se
proporcionar en forma de reproducciones heliogrficas y/o fotocopiado, claramente legibles, para formar
dos (2) juegos, y deber ser entregada conforme se vaya desarrollando el proyecto, basndose en el
programa aprobado.
No se aceptar que la documentacin est incompleta, o que las copias no sean legibles y/o que est
desordenada, sin ndice, sin paginacin o con diagramas borrosos.
Es necesario que la documentacin sea entregada al S.T.C., de manera relacionada y cuando sea necesario
se aceptarn anexos, siempre y cuando estos estn perfectamente identificados.
Se deber entregar la documentacin preliminar en el idioma espaol.
Pg. 63 de 78
3.6.2.
Documentacin definitiva
Esta documentacin es la que comprende toda la documentacin de estudios y preliminar corregida con
base a como qued instalado y funcionando el sistema de vdeo vigilancia, en forma total y completa.
La documentacin definitiva consistir de un juego en original y 2 copias claramente legibles, que permitan el
fotocopiado cuando se requiera; el S.T.C., podr rechazar dicha documentacin si no cumple con lo antes
citado.
El plazo mximo para entregar esta documentacin ser el da de la recepcin provisional del grupo de
estaciones marcada como entregable, antes de esta fecha dicha documentacin deber ser presentada a la
Coordinacin Tcnica con por lo menos 10 das hbiles antes de concluir la instalacin del entregable al
S.T.C. para su revisin y aprobacin.
Toda esta documentacin deber presentarse en idioma espaol. Adems de los juegos de documentacin
anteriormente solicitados, el proveedor deber proporcionar esta documentacin en idioma espaol en dos
juegos de CDs, o DVDs, elaborados en procesador de textos WORD versin 2003, para WINDOWS
XP, para los manuales operativos, tcnicos y de mantenimiento; y en AUTOCAD ltima versin, lo
correspondiente a los planos, diagramas de principio, etc., que se requieran. Las versiones en que fueron
elaborados los documentos, planos, diagramas de principio, etc., debern ser indicadas en las etiquetas de
identificacin de los CD`s o DVDs.
7. Plan de Pruebas
Los procedimientos de pruebas que sern aplicados a los equipos, conjuntos o subconjuntos, son lo
siguientes:
Recepcin provisional
La recepcin provisional se considerar realizada a la puesta en servicio del equipo y/o sistema
involucrado, despus de haber pasado satisfactoriamente las pruebas realizadas en cada instalacin, segn
el programa de pruebas acordado previamente entre el proveedor y el S.T.C..
Al concluirse las pruebas de recepcin provisional, se levantar un acta donde se indiquen las condiciones
de la puesta en servicio del equipo o sistema indicndose si se declara o no recibido provisionalmente el
equipo o sistema.
Las fallas menores (que no comprometan la operacin y funcionalidad del sistema) y que hayan sido
anotadas en el acta de recepcin que no se hayan resuelto en el plazo de 15 das calendario, se
considerarn no atendidas y la garanta del equipo y/o sistema se considerar automticamente prorrogada
en el tiempo que se exceda en la resolucin de estas.
Pg. 64 de 78
Recepcin definitiva
La recepcin definitiva de los equipos suministrados ser llevada a cabo al trmino del perodo de garanta
general, si todas las obligaciones correspondientes ya fueron cumplidas, y que todas las reservas emitidas en
el acta de recepcin provisional y perodo de garanta hayan sido resueltas a satisfaccin del S.T.C.,
levantndose el acta de cumplimiento.
8. Capacitacin
El proveedor deber efectuar los estudios de ingeniera necesarios para el buen desarrollo del proyecto:
Adems, el proveedor deber proporcionar al personal que designe el S.T.C. cursos de capacitacin que
incluirn la operacin, el funcionamiento, mantenimiento y software utilizado en la programacin, as como
las recomendaciones y cuidados que se deben tener a los equipos, conjuntos y subconjuntos del sistema,
dicha capacitacin comprender:
Pg. 65 de 78
Asimismo se incluirn los temas que por la experiencia del proveedor considere necesarios para que el
personal tcnica de la Coordinacin Tcnica puede llevar a cabo las labores de mantenimiento preventivo y
correctivo tanto de los equipos en forma individual, como del sistema en si conjunto.
El lugar de imparticin del curso para el caso de las instalaciones ser en las oficinas del proveedor..
Los cursos de capacitacin para la instalacin debern ser impartidos a 20 personas divididos en 2 grupos
en turno matutino y vespertino (un grupo por turno), la fecha de inicio y horario de los cursos sern
determinados por el S.T.C., de acuerdo al programa de actividades que se defina.
El curso de capacitacin para el mantenimiento deber ser impartido a 20 personas divididos en 2 grupos
en turno matutino y vespertino (un grupo por turno), en donde la fecha de inicio y horario del curso ser
definido por el S.T.C., de acuerdo al programa de actividades que se defina.
La documentacin que servir para la imparticin de cada curso deber ser entregada al S.T.C., a ms
tardar diez das hbiles antes del inicio de la capacitacin, para su aprobacin. Esta documentacin
Pg. 66 de 78
9. Garanta y Mantenimiento
El proveedor es responsable de garantizar y mantener el buen funcionamiento del equipo o sistema
suministrado durante un plazo que se menciona a continuacin:
La reposicin de cualquier equipo, mdulo o elemento debe ser por otro igual, no aceptndose
equivalentes.
En el caso en que a pesar de las intervenciones, el funcionamiento de un aparato, subconjunto o dispositivo
continuara fallando, el proveedor estar obligado a reemplazar, por su cuenta, no solamente el elemento
daado, sino la totalidad de los elementos del mismo tipo que existan en cada conjunto o subconjunto, por
elementos de un modelo o serie diferente y equivalente sometido a la previa aceptacin del S.T.C. La
garanta para los materiales que hayan sido reemplazados por falla sistemtica se extender por un nuevo
perodo de veinticuatro (24) meses.
Todo perjuicio ocasionado a otros equipos o a la operacin del S.T.C. debido a una falla del equipo y/o
sistema en garanta o a las intervenciones del proveedor ser responsabilidad del mismo, de acuerdo a lo
establecido en las leyes mexicanas.
9.4. CONSIDERACIONES
PROVISIONAL
HASTA
LA
RECEPCIN
Incluye:
Pg. 68 de 78
Pg. 69 de 78
Mantenimiento correctivo
El mantenimiento correctivo a cargo del proveedor consistir en la reparacin de todas las fallas de equipo
y/o sistema, para su correcto funcionamiento. Para cumplir con lo anterior, el proveedor deber contar con
los recursos materiales y humanos necesarios para que en este perodo se tenga disponibilidad para asistir a
atender las fallas presentadas en cualquier da de la semana, las 24 horas del da, los 365 das del ao.
Para garantizar la eficiencia de estos trabajos, el personal del proveedor responsable del mantenimiento
deber proporcionar una forma de comunicacin rpida y directa con l, para la atencin de las averas que
puedan ocurrir, con el objeto de facilitar su localizacin.
El seguimiento a lo anterior, ser de la siguiente manera:
Al presentarse la falla en uno de los equipos del sistema suministrado, el encargado del mantenimiento de los
equipos y/o sistema por parte del S.T.C., se comunicar va telefnica con la persona responsable del
mantenimiento en la Ciudad de Mxico, describindole a ste las caractersticas de la falla con el propsito
Pg. 70 de 78
Pg. 71 de 78
Suministro de los gabinetes, repartidores, conectores, pig-tails, patch-cords, etc necesarios para
implementar todas las conexiones necesarias para la implementacin de la Red Multiservicio (segn
la topologa definida por el licitante), teniendo en cuenta que todas las fibras (incluyendo las no
utilizadas), sern conectorizadas en todas las estaciones.
Electrnica de Red
Suministro, tendido y conexionado de los latiguillos de F.O. necesarios para interconectar los
equipos suministrados, segn la topologa definida por el licitante.
Pg. 72 de 78
Todos los equipos de la solucion debern ser de la misma marca para evitar incopatibilidad e
inoperatividad de los mismos.
rea I. la Catlica
222 Puntos de Red
rea Chabacano
132 Puntos de Red
rea Delicias
263 Puntos de Red
rea Juarez
333 Puntos de Red
rea Balbuena
85 Puntos de Red
rea Sevilla
98 Puntos de Red
rea Cuauhtemoc (y policlnica) 306 Puntos de Red
rea Revolucin
250 Puntos de Red
rea Guelatao
76 Puntos de Red
rea Salto del Agua
279 Puntos de Red
Ingeniera Desarrollo/ INCADE 250 Puntos de Red
rea Zapata
40 Puntos de Red (Estimado)
rea Guerrero
40 Puntos de Red (Estimado)
SEAT Oceana
40 Puntos de Red (Estimado)
SEAT Estrella
40 Puntos de Red (Estimado)
Pg. 73 de 78
Para la conexin del Sistema de Tarjeta sin contacto se deben suministrar 175 cables de cobre UTP de
aproximadamente 10 m. para la conexin del equipo Concentrador de Estacin de este sitema hacia el
Nodo de Acceso de la Red de Comunicaciones y Servicios.
Suministro de la canalizacin y los cables para la conexin de los sistemas de Sistema de
Videovigilancia y Sistema Integral de Alarmas
o 185 Subestaciones de Rectificacin (SRs)
Enlace con par de cobre categora mnima 5, para instalacin de alarmas y videovigilancia.
11.1. Topologa
La red de comunicaciones estar conformada por una Red Principal (backbone), con equipos clase
metropolitana en tecnologa plataforma de transporte multiservicios 10 Gigabit Ethernet, interconectados
entre s por medio de fibra ptica monomodo, en forma de anillo redundante, Redes de Distribucin por
Lnea, interconectadas en forma de rbol redundante por medio de fibra ptica monomodo a Gigabit
Ethernet, y un nivel de Red de Acceso por cada estacin o punto de importancia relacionado en los
objetivos; adems contar con todo el equipamiento necesario para proporcionar conexin a la aplicacin
de los diversos servicios, equipamiento como: cables de cobre (UTP) y paneles de parcheo.
Esto hace conveniente que el trfico de las estaciones se concentre por Lneas y alcance los Puestos de
Control en un nmero reducido de saltos.
Para ste propsito se desempear bajo una arquitectura jerrquica, con niveles y funciones claramente
definidos: Red Primaria (Ncleo, backbone), Red Secundaria (distribucin), Red de Acceso y Aplicacin.
Descritos a continuacin y mostrados en la figura 1.
Pg. 74 de 78
Estructura Jerrquica.
Pg. 75 de 78
11.1.2 Funciones
El anillo de Backbone o Red Principal de fibra ptica realizar la transferencia de informacin del Sistema
bajo tecnologa DWDM a 10 Gigabit en una plataforma metropolitana de transporte multiservicios IP; la
tecnologa de toda la Red de Comunicaciones, en sus tres niveles, debe ser la apropiada que suministre
servicios de transporte de voz, datos y video.
Los Nodos de Distribucin, realizaran la interconexin delos Nodos de Acceso de las estaciones y el enlace
hacia la Red Primaria. Los Nodos de Acceso, en la Red de Distribucin fungirn como puesto de enlace en
las estaciones, proporcionando el punto de conexin a las Redes de Acceso.
El parmetro principal de diseo es la alta disponibilidad de la red. Es preciso que todos los equipos
dispongan de redundancia a nivel de enlaces, descartando la existencia de un punto de fallo en la red.
Pg. 76 de 78
Red de Acceso, sta conexin emplear equipos satlites (Nodo de Red Local) en una arquitectura de
estrella, fungir como puente conectando los nodos secundarios a los sistemas o redes locales. Existir un
equipo de acceso por cada sitio en que sea requerido el enlace de alguna aplicacin, si sta conexin est
ubicada fuera de la estacin (edificio administrativo, garage, etc.). Adems se incluir un equipo de acceso
en los casos en los que por el nmero de interfaces necesarios, por la naturaleza de la aplicacin o por la
ubicacin fsica de los usuarios, sea necesario incluir nodos adicionales.
Pg. 77 de 78
Pg. 78 de 78