Академический Документы
Профессиональный Документы
Культура Документы
2/S280
SCI
JOB REFERENCE:
DECK REFERENCE:
COMPANY NAME:
CLIENT NAME:
Tata Steel
NOVO CINEMA
CF46/1.2_280
FILENAME:
Calcs by:
Page 1 of 6
v9.0.22.0
1/8/2015
12:07:22
Date:
Time:
Job No.:
Checked by:
FULL OUTPUT
NOTE: SECTION DESIGNED TO BRITISH STANDARDS
Construction Stage:
PASS
Max Unity Factor = 0.46
Normal Stage:
PASS
Max Unity Factor = 0.18
Fire Condition:
PASS
Max Unity Factor = 0.37
Serviceability:
SATISFACTORY
Max Unity Factor = 0.19
*** SECTION ADEQUATE ***
FLOOR PLAN DATA : (unpropped composite construction with ComFlor 46/1.2/S280 decking)
Beam centres - equal
1.90 m
Span type
DOUBLE
Beam or wall width
152 mm
Propping
NONE
PROFILE DATA : (ComFlor 46/1.2/S280 decking)
Depth
46 mm
Trough width
105 mm
Nominal sheet thickness
1.20 mm
Deck weight
0.13 kN/m
Mesh
Cover to Mesh
Account for End Anchorage
Diameter of Shear Connectors
Screeds
A193
30 mm
NO
N/A
N/A
Yield strength
Mesh Layers
Shear connectors per rib
225 mm
67.0 mm
1.16 mm
280 N/mm
2400 kg/m
2350 kg/m
460 N/mm
Single
N/A
SECTION PROPERTIES :
***NOTE - 1: All values of inertia are expressed in steel units
***NOTE - 2: Average inertia is used for deflection calculations for the composite stage
***NOTE - 3: Cracked dynamic inertia is used for natural frequency calculations
DECK PROFILE:
File Name:
53.000 cm4/m
0.000 cm4/m
1534 mm/m
v9.0.22.0
ComFlor 46/1.2/S280
Page 2 of 6
COMPOSITE:
Inertia, Ixx - Uncracked
3624 cm4/m
Cracked
1835 cm4/m
Average inertia
2730 cm4/m
2077 cm4/m
86.80
Kr
0.039600
Concrete volume
0.146 m/m/m
5.00 kN/m
Partitions
1.00 kN/m
0.50 kN/m
Finishes
0.50 kN/m
3.43 kN/m
0.13 kN/m
3.36 kN/m
Screeds
NONE
Construction load
2.4 kN/m
120 mins
FIRE DATA :
Design method
SIMPLE
0.0 kN/m
1.40
Imposed
1.60
1.40
0.80
File Name:
v9.0.22.0
ComFlor 46/1.2/S280
Page 3 of 6
CONSTRUCTION STAGE
LOADINGS
Unfactored(kN/m)
0.13
3.43
2.37
0.79
= 0.18 + 4.81 + 0.00 + 3.79
= 8.78 kN/m
Factored(kN/m)
0.18
4.81
3.79
1.26
= 1.90 m
= 1.75 + 46.0 / 1000
= 1.79 m
= 1.79 m
PASS
16.96 kN/m
68.99 kN/m
= 0.25
PASS
NOTE: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
SAGGING:
HOGGING:
PASS
= 2.13 kNm/m
= 6.23 kNm/m
= 0.34
PASS
File Name:
v9.0.22.0
ComFlor 46/1.2/S280
Page 4 of 6
= 1.85 mm
( < 9.97 mm )
***NOTE: Deflection within code limits; ponding is not considered
File Name:
SATISFACTORY
v9.0.22.0
ComFlor 46/1.2/S280
Page 5 of 6
NORMAL STAGE
LOADINGS : (see construction load calculations for details):
Dead
Imposed
Superimposed dead
Total
Unfactored (kN/m)
0.13 + 3.36
= 3.49
5.00 + 1.00
= 6.00
0.50 + 0.50 + 0.00
= 1.00
= 10.49 kN/m
Factored (kN/m)
4.89
9.60
1.40
15.89 kN/m
EFFECTIVE SPAN :
PASS
Not Applicable
Shear span
Applied shear
Shear bond resistance
Anchorage resistance
Total shear resistance
UNITY FACTOR
= 1.89 / 4
= 0.47 m
= 10.41 kN/m
= (1000 * 144.56/1.25) * [86.80 * 1534.00 / (1000 * {0.47 * 1000} + 0.04 * 40.00)]
/ 1000 kN/m
= 61.51 kN/m
= 0 kN/m
= (61510.01/1000) + [(0/1000)]/2 = 61.51 kN/m
= 0.17
PASS
PASS
v9.0.22.0
ComFlor 46/1.2/S280
Page 6 of 6
DEFLECTION CHECK :
Allowable deflection max-i under imposed loads, is the lesser of
1) Effective span/350 (= 5.4 mm ), and
2) Absolute maximum value (mm) = 20
Imposed load deflection
Allowable total deflection max-t, is the lesser of
1) Effective span/250 or 7.6 mm, and
2) 30 mm ( SCI recommended absolute maximum value )
Deflection due to imposed loads
Additional deflection due to superimposed dead loads
Total deflection
PASS
SATISFACTORY
DYNAMIC SENSITIVITY :
*** NOTE: loads are dead + super-imposed dead + 10% imposed
File Name:
= 2077 cm4
= 0.013 * 5.09 * (1.89* 1000 )^4 / (205*20769060 )/1000
= 0.20 mm
= 18 / 0.20 )
= 40.13 Hz ( > 5.00 Hz)
SATISFACTORY
v9.0.22.0