Вы находитесь на странице: 1из 6

ComFlor 46/1.

2/S280

BS 5950 Parts 4, 6 and 8

SCI
JOB REFERENCE:
DECK REFERENCE:
COMPANY NAME:
CLIENT NAME:

Tata Steel
NOVO CINEMA
CF46/1.2_280

FILENAME:

Calcs by:

Page 1 of 6

v9.0.22.0
1/8/2015
12:07:22

Date:
Time:
Job No.:
Checked by:

FULL OUTPUT
NOTE: SECTION DESIGNED TO BRITISH STANDARDS
Construction Stage:
PASS
Max Unity Factor = 0.46
Normal Stage:
PASS
Max Unity Factor = 0.18
Fire Condition:
PASS
Max Unity Factor = 0.37
Serviceability:
SATISFACTORY
Max Unity Factor = 0.19
*** SECTION ADEQUATE ***
FLOOR PLAN DATA : (unpropped composite construction with ComFlor 46/1.2/S280 decking)
Beam centres - equal
1.90 m
Span type
DOUBLE
Beam or wall width
152 mm
Propping
NONE
PROFILE DATA : (ComFlor 46/1.2/S280 decking)
Depth
46 mm
Trough width
105 mm
Nominal sheet thickness
1.20 mm
Deck weight
0.13 kN/m

Pitch of deck ribs


Crest width
Design sheet thickness
Yield strength

CONCRETE SLAB : [Normal Weight Concrete ; Mesh : A193]


Overall slab depth
165 mm
Concrete characteristic strength 40 N/mm
Concrete wet density
Modular ratio
10
Concrete dry density
Bar reinforcement
NONE
Mesh reinforcement :

Mesh
Cover to Mesh
Account for End Anchorage
Diameter of Shear Connectors
Screeds

A193
30 mm
NO
N/A
N/A

Yield strength
Mesh Layers
Shear connectors per rib

225 mm
67.0 mm
1.16 mm
280 N/mm
2400 kg/m
2350 kg/m
460 N/mm
Single
N/A

SECTION PROPERTIES :
***NOTE - 1: All values of inertia are expressed in steel units
***NOTE - 2: Average inertia is used for deflection calculations for the composite stage
***NOTE - 3: Cracked dynamic inertia is used for natural frequency calculations

DECK PROFILE:

Sagging Inertia, Ixx


Hogging Inertia, Iyy

File Name:

53.000 cm4/m
0.000 cm4/m

Area of profile (Net), Ap

1534 mm/m

v9.0.22.0

ComFlor 46/1.2/S280

BS 5950 Parts 4, 6 and 8

Page 2 of 6

COMPOSITE:
Inertia, Ixx - Uncracked

3624 cm4/m

Cracked

1835 cm4/m

Average inertia

2730 cm4/m

Cracked inertia (dynamic)

2077 cm4/m

Shear bond coefficients - Mr

86.80

Kr

0.039600

Concrete volume

0.146 m/m/m

LOADS ACTING ON SLAB :


*** NOTE: Slab subjected to uniformly distributed loads (UDL) ONLY
Imposed (occupancy)

5.00 kN/m

Partitions

1.00 kN/m

Ceilings and services

0.50 kN/m

Finishes

0.50 kN/m

Self weight of concrete slab (wet)

3.43 kN/m

Self weight of decking

0.13 kN/m

Self weight of concrete slab (dry)

3.36 kN/m

Screeds

NONE

Construction load

2.4 kN/m

Fire resistance period

120 mins

LINE LOADS PERPENDICULAR TO DECK SPAN :


None

LINE LOADS PARALLEL TO DECK SPAN :


None

FIRE DATA :
Design method

SIMPLE

Non-permanent imposed loads

0.0 kN/m

PARTIAL SAFETY FACTORS :


Dead (self weight)

1.40

Imposed

1.60

Super imposed dead

1.40

Fire (occupancy loads)

0.80

File Name:

v9.0.22.0

ComFlor 46/1.2/S280

BS 5950 Parts 4, 6 and 8

Page 3 of 6

CONSTRUCTION STAGE
LOADINGS

Self weight of decking


Self weight of concrete slab (wet)
Construction load (one span)
Construction load (adjacent span(s))
Total factored load (maximum)

Unfactored(kN/m)

0.13
3.43
2.37
0.79
= 0.18 + 4.81 + 0.00 + 3.79
= 8.78 kN/m

Factored(kN/m)

0.18
4.81
3.79
1.26

EFFECTIVE SPAN OF DECK :

Effective span Le, is the smaller of


1) c/c of supports
2) clear span + deck depth
Therefore Le

= 1.90 m
= 1.75 + 46.0 / 1000
= 1.79 m
= 1.79 m

SHEAR RESISTANCE CHECK :

*** Check at first interior support position


Applied shear
Shear strength of decking, pv
Shear resistance, Pv
UNITY FACTOR

= [1.250 * 0.18 + 1.250 * 4.81 + 1.250 * 0.05 + 2.500 * 3.79/3] * 1.79 / 2


= 8.48 kN/m
= 168.0 N/mm
= 79.7 kN/m
= 0.11

PASS

16.96 kN/m
68.99 kN/m
= 0.25

PASS

WEB CRUSHING RESISTANCE CHECK :

*** Check at first interior support position


Applied reaction
Web crushing resistance, Pw
UNITY FACTOR
BENDING RESISTANCE CHECK :

NOTE: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
SAGGING:

Max applied moment


Moment resistance, Mc
UNITY FACTOR

HOGGING:

Max. applied moment


Moment resistance, Mc
UNITY FACTOR

= [0.070 * 0.18 + 0.096 * 4.81 + 0.096 * 0.05 + 0.096 * 3.79] * 1.79^2


= 2.71 kNm/m
= 5.99 kNm/m
= 0.45

PASS

= 2.13 kNm/m
= 6.23 kNm/m
= 0.34

PASS

INTERACTION OF BENDING MOMENT AND SHEAR :

NOTE 1: *** Check at first interior support position


NOTE 2: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
Applied shear
= 7.97 kN/m
Shear resistance, Pv
= 79.68 kN/m
Applied moment
= 2.13 kNm/m
Moment resistance, Mc
= 6.23 kNm/m
UNITY FACTOR
= [7.97/79.68]^2 + [2.13/6.23]^2
= 0.13
PASS

File Name:

v9.0.22.0

ComFlor 46/1.2/S280

BS 5950 Parts 4, 6 and 8

Page 4 of 6

INTERACTION OF BENDING MOMENT AND WEB CRUSHING :

NOTE 1: *** Check at first interior support position


NOTE 2: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
Applied reaction
= 15.95 kN/m
Web crushing resistance, Pw
= 79.68 kN/m
Applied moment
= 2.13 kNm/m
Moment resistance, Mc
= 6.23 kNm/m
UNITY FACTOR
= [15.95/68.99 + 2.13/6.23]
= 0.57 < 1.25
PASS
DEFLECTION CHECK :

Allowable deflection max, is the lesser of


1) Effective span/180 (= 10.0 mm ), and
2) 20 mm ( absolute maximum value ), and
3) Slab depth/10 = ( 16.5 mm )
Max. self weight deflection

= 1.85 mm
( < 9.97 mm )
***NOTE: Deflection within code limits; ponding is not considered

File Name:

SATISFACTORY

v9.0.22.0

ComFlor 46/1.2/S280

BS 5950 Parts 4, 6 and 8

Page 5 of 6

NORMAL STAGE
LOADINGS : (see construction load calculations for details):

Dead
Imposed
Superimposed dead
Total

Unfactored (kN/m)
0.13 + 3.36
= 3.49
5.00 + 1.00
= 6.00
0.50 + 0.50 + 0.00
= 1.00
= 10.49 kN/m

Factored (kN/m)
4.89
9.60
1.40
15.89 kN/m

EFFECTIVE SPAN :

Effective span Le, is the smaller of


1) c/c of supports
2) clear span + slab overall depth - depth to centroid = 1.75 + 165 / 1000 - 20.44 / 1000
= 1.89 m
Therefore Le
= 1.89 m

SHEAR RESISTANCE CHECK :

Maximum applied shear

Shear stress in concrete, v


Shear strength of concrete, vc
Shear resistance
UNITY FACTOR

= 0.5 * 15.89 * 1.89


= 15.08206
= 0.18 N/mm
= 0.97 N/mm
= 131.50 * 144.56 * 0.97 / 225.00
= 82.16 kN/m
= 0.18

PASS

PUNCHING SHEAR CHECK :

Not Applicable

SHEAR BOND RESISTANCE CHECK :

Shear span

Applied shear
Shear bond resistance
Anchorage resistance
Total shear resistance
UNITY FACTOR

= 1.89 / 4
= 0.47 m
= 10.41 kN/m
= (1000 * 144.56/1.25) * [86.80 * 1534.00 / (1000 * {0.47 * 1000} + 0.04 * 40.00)]
/ 1000 kN/m
= 61.51 kN/m
= 0 kN/m
= (61510.01/1000) + [(0/1000)]/2 = 61.51 kN/m
= 0.17
PASS

BENDING RESISTANCE CHECK :

Applied bending moment

= 0.125 * 15.89 * 1.89^2


= 7.14 kNm/m
Depth of concrete stress block
= 22.19 mm
NOTE: depth of concrete in compression may be limited to 0.45 ds
Tension in decking
= 399.45 kN/m
Tension in bar reinforcement
= 0.00 kN/m
Depth to position of resultant tension
= (0.0 * 135.0 + 399.5 * 144.6) / (0.0 + 399.5)
= 144.56 mm
Lever arm
= 133.46 mm
NOTE: lever arm may be limited to 0.95 ds
Compression in concrete
= 399.45 kN/m
Moment resistance
= 399.45 * 133.46/1000
= 53.31 kNm/m
UNITY FACTOR
= 0.13
File Name:

PASS
v9.0.22.0

ComFlor 46/1.2/S280

BS 5950 Parts 4, 6 and 8

Page 6 of 6

FIRE RESISTANCE CHECK :


Effective span in fire, is the greater of
1) c/c suppports - support width

= 1.90 - 152 / 1000


= 1.75 m
2) c/c supports - 150
= 1.90 - 150 / 1000
= 1.75 m
i.e effective span in fire
= 1.75 m
Fire dead load
= 0.13 + 3.36 + 0.50 + 0.50 + 0.00
= 4.56 kN/m
Non-permanent fire imposed load
= 0.80 * 0.0 *5.00
= 0.0 kN/m
Permanent fire imposed load
= (1 - 0.0) *5.00 + 1.00
= 6.00 kN/m
Fire imposed load
= 0.00 + 6.00
= 6.00 kN/m
Fire free moment
= 4.04 kNm/m
Moment resistance, sagging
= 5.45 kNm/m
Moment resistance, hogging
= 12.84 kNm/m
Moment resistance, Mr
= 5.45 + 0.45 * 12.84 *** for end span
= 10.93 kNm/m
UNITY FACTOR
= 0.37
As spans are approximately equal, no check on uplift at an external support has been made

DEFLECTION CHECK :
Allowable deflection max-i under imposed loads, is the lesser of
1) Effective span/350 (= 5.4 mm ), and
2) Absolute maximum value (mm) = 20
Imposed load deflection
Allowable total deflection max-t, is the lesser of
1) Effective span/250 or 7.6 mm, and
2) 30 mm ( SCI recommended absolute maximum value )
Deflection due to imposed loads
Additional deflection due to superimposed dead loads
Total deflection

PASS

= 0.013 * 6.50 * (1.89* 1000 )^4 / (205*27297130 )/1000


= 0.2 mm ( < 5.4 mm )
SATISFACTORY

= 0.2 mm (based on average inertia)


= 0.0 mm (based on average inertia)
= 0.2 + 0.0
= 0.2 mm ( < 7.6 mm )

SATISFACTORY

DYNAMIC SENSITIVITY :
*** NOTE: loads are dead + super-imposed dead + 10% imposed

Dynamic inertia (cracked section)


Maximum deflection
Frequency

File Name:

= 2077 cm4
= 0.013 * 5.09 * (1.89* 1000 )^4 / (205*20769060 )/1000
= 0.20 mm
= 18 / 0.20 )
= 40.13 Hz ( > 5.00 Hz)
SATISFACTORY

v9.0.22.0

Вам также может понравиться