1.
GENERAL
1.1
INTRODUCTION
1.1.1
Scope
This Section specifies the general requirements for various methods and types of interior
finishes within buildings for walls, floors, and ceilings.
1.1.2
References
QCS 2010
Portland cement
Fire tests on building materials and structures
Testing aggregates
Aggregates from natural sources for concrete
Building limes
Methods of test for colour fastness of textiles
Pigments for Portland cement and Portland and cement products
Nails
Gypsum plasterboard
Fixing accessories for building purposes
Electroplated coatings of cadmium and zinc on iron and steel
Building sands from natural sources
Building sands from natural sources
Thermoplastic flooring tiles
Copper and copper alloys rod and sections (other than forging stock)
Semi-flexible PVC floor tiles
Unbacked flexible PVC flooring
Bitumen based coating for cold application, suitable for use in contact with
potable water
Terrazzo tiles
Determination of constructional details of textile floor coverings with yarn pile
Methods of test for dimensional stability of textile floor coverings
Code applied joint sealant systems for concrete pavements
Masonry cement
Code of practice for the installation of textile floor coverings
Code of practice for external rendering
Code of practice for stone masonry
Underlays for textile floor coverings
Adhesive for use with ceramic tiles and mosaics
Code of practice for false work
Precast concrete masonry units
Ceramic floor and wall tiles
Workmanship on building sites
Code of practice for installation of sheet and tile flooring
In-situ flooring
BURHAN INTERNATIONAL
Section 1
Section 5
Section 15
Section 17
Section 18
Section 26
QCS 2010
Section 24
BS EN 10142
BS EN 10143
Part 1
General
Page 3
Continuously hot-dip zinc coated low carbon steel sheet and strip for cold
forming: technical delivery conditions.
Continuously hot-dip metal coated steel sheet and strip Tolerances and
dimensions and shape
Workmanship
1.1.4
Scaffolding
Scaffolding is to be erected to external facades and any other areas where it is required
before any work is commenced, so that good access is obtained to the whole of the working
area
1.2
1.2.1
Samples
Sample panels minimum size 600 x 600mm are to be prepared for all textured coatings to be
used in the Works.
QCS 2010
BURHAN INTERNATIONAL
1.1.3