Вы находитесь на странице: 1из 10

Plinth beam FOR SCREEN HOUSE

Beam Data
width
depth
clear cover to
main reinf.
Material Grades
Concrete
Steel
Span Moment
End Moment

Span
End

Area of Steel
Percentage
Area of Steel

250 mm
400 mm
25 mm

d'
eff depth

35 mm
365 mm

25 MPa
415 MPa
Normal moment

Torsional moment

Equivalent moment

60 KN-m
60 KN-m

0 KN-m
0 KN-m

60
60

Span Condition End Condition

Mu/bd2
xumax
Mulim
Mulim/bd2

1.80
175
115
3.45

1.80
175
115
3.45

Beam is designed as Singly Reinforced Beam


Beam is designed as Singly Reinforced Beam
Span Reinforcement
Tension (Ast)
0.549 %

Compr (Asc)

Area of Steel
Percentage
Area of Steel

-------

501 sqmm

Tension Reinforcement for span moment


Type
Bar dia
Layer 1
20 mm
Layer 2
25 mm
Layer 3
32 mm
Total Steel Provided

Nos
3
0
0

Area of Steel
942 sqmm
0 sqmm
0 sqmm
942 sqmm

End Reinforcement
Tension (Ast) Compr (Asc)

1.033 %

0.549 %

-------

501 sqmm

Tension Reinforcement for end moment


Bar dia
Nos
16 mm
2
20 mm
1
32 mm
0
Total Steel Provided

Provided Steel OK

Provided Steel OK

Compression Reinforcement for span moment


Type
Bar dia
Nos
Layer 1
20 mm
4
Layer 2
12 mm
4
Layer 3
Total Steel Provided

Shear Force (Vu)


Tortional Moment
Equivalent Shear
v
c
cmax

Type
Layer 1
Layer 2
Layer 3

30 KN
0 KN-m
30 KN
0.329
0.868
3.1

Bar Dia
20 mm
16 mm
12 mm

Compression Reinforcement for end moment


Bar dia
Nos
20 mm
3
12 mm
0

Area of Steel

#VALUE!

.=Vu / (b * d)
Refer Table 61 SP 16 pg 179
Refer Table J SP 16 pg 175

Nos
Area of Steel
7
2199 sqmm
0
0 sqmm
0
0 sqmm
Total Steel Provided 2199 sqmm

Sectional Dimensions OK
Shear Check OK
Provide Nominal Shear Reinforcement

Total Steel Provided

or =(0.85*(0.8*fck)*(1+5)-1)) / (6)

2.410 %

Type of stirrup
Stirrup diameter
Spacing
Provide

2 legged
8 mm
274 c/c
150 mm c/c

OK

Plinth beam FOR SCREEN HOUSE

.= cc+ sdia + mdia/2


.= d - d'

.= (700/(1100 * (0.87 * fy)) * d


.= 0.36*fck*b*xumax*(d-(0.42*xumax))

Refer Table 2 SP 16 pg 48

Tension Reinforcement for end moment


Area of Steel
402 sqmm
314 sqmm
0 sqmm
716 sqmm
Provided Steel OK
Compression Reinforcement for end moment
Area of Steel

or =(0.85*(0.8*fck)*(1+5)-1)) / (6)

Steel Calculation for span moment

Grade Check
7.8
SRB
a
b
c
-p
Ast

0.60
-3.611
1.801
0.549
501

.=(0.87435/100) * (fy/fck)2
.=(0.87/100) * (fy)
.=Mu/bd2
.=-(b(b2-4ac))/2a
.=(p*b*d)/100

0.0959
0.1

DRB
a
b
c
-p
Astlim

0.60
-3.611
3.453
1.194
1090

Mu2
Ast2
Ast

-55
-462
628

.=Mu - Mulim
.=Mu2/((0.87*fy)*(d-d'))
.=Astlim+Ast2

d'/d
fsc
fcc
Asc

0.10
353
11.15
-487

Refer Table F SP 16 pg 13
.=0.466*fck
.=Mu2/((fsc-fcc)*(d-d'))

Min steel %
Ast
Asc

0.205
501
-487

.=0.85% / fy

Min Steel
Max Steel

187
3650

.=(0.85*b*d) / fy
.=0.04*b*d)

Ast
Asc

501

Pt provided
Pc provided

2.410

Shear Calculations

1.204

Shear Capacity of Concrete (Vs)


Shear Stg to be caried by Stirrup (Vus)
Spacing
actual req
min
max
max
X1
(X1+X2)/4

417
363
274
300
184
129

79
-49

.=(Asv*0.87fy*d)/Vus
.=(Asv*0.87fy)/(b*0.4)
.=0.75d
.=300mm

.=c*b*d
.=Vu-Vs
provide the
least of the 6

.=(Ast*100)/(b*d)
.=(Asc*100)/(b*d)
.=(0.8*fck)/(6.89*Pt)

.=(0.87435/100) * (fy/fck)2
.=(0.87/100) * (fy)
.=Mulim/bd2
.=-(b(b2-4ac))/2a
.=(p*b*d)/100

Plinth beam for crusher house


Beam Data
width
depth
clear cover to
main reinf.
Material Grades
Concrete
Steel
Span Moment
End Moment

Span
End

Area of Steel
Percentage
Area of Steel

250 mm
400 mm
25 mm

d'
eff depth

33 mm
367 mm

25 MPa
415 MPa
Normal moment

Torsional moment

Equivalent moment

20 KN-m
20 KN-m

0 KN-m
0 KN-m

20
20

Span Condition End Condition

Mu/bd2
xumax
Mulim
Mulim/bd2

0.59
176
116
3.45

0.59
176
116
3.45

Beam is designed as Singly Reinforced Beam


Beam is designed as Singly Reinforced Beam
Minimum % of Steel as per IS 456 clause 25.5 required
Span Reinforcement
End Reinforcement
Tension (Ast)
Compr (Asc)
Area of Steel Tension (Ast) Compr (Asc)
0.205 %
------0.205 %
------Percentage
188 sqmm
Area of Steel 188 sqmm

Tension Reinforcement for span moment


Type
Bar dia
Layer 1
16 mm
Layer 2
25 mm
Layer 3
32 mm
Total Steel Provided

Nos
3
0
0

Area of Steel
603 sqmm
0 sqmm
0 sqmm
603 sqmm

0.657 %

Tension Reinforcement for end moment


Bar dia
Nos
16 mm
3
16 mm
0
32 mm
0
Total Steel Provided

Provided Steel OK

Provided Steel OK

Compression Reinforcement for span moment


Type
Bar dia
Nos
Layer 1
20 mm
4
Layer 2
12 mm
4
Layer 3
Total Steel Provided

Shear Force (Vu)


Tortional Moment
Equivalent Shear
v
c
cmax

Type
Layer 1
Layer 2
Layer 3

20 KN
0 KN-m
20 KN
0.218
0.709
3.1

Bar Dia
16 mm
16 mm
12 mm

Compression Reinforcement for end moment


Bar dia
Nos
20 mm
3
12 mm
0

Area of Steel

#VALUE!

.=Vu / (b * d)
Refer Table 61 SP 16 pg 179
Refer Table J SP 16 pg 175

Nos
Area of Steel
6
1206 sqmm
0
0 sqmm
0
0 sqmm
Total Steel Provided 1206 sqmm

Sectional Dimensions OK
Shear Check OK
Provide Nominal Shear Reinforcement

Total Steel Provided

or =(0.85*(0.8*fck)*(1+5)-1)) / (6)

1.315 %

Type of stirrup
Stirrup diameter
Spacing
Provide

2 legged
8 mm
275 c/c
175 mm c/c

OK

Plinth beam for crusher house

.= cc+ sdia + mdia/2


.= d - d'

.= (700/(1100 * (0.87 * fy)) * d


.= 0.36*fck*b*xumax*(d-(0.42*xumax))

Refer Table 2 SP 16 pg 48

Tension Reinforcement for end moment


Area of Steel
603 sqmm
0 sqmm
0 sqmm
603 sqmm
Provided Steel OK
Compression Reinforcement for end moment
Area of Steel

or =(0.85*(0.8*fck)*(1+5)-1)) / (6)

Steel Calculation for span moment

Grade Check
7.8
SRB
a
b
c
-p
Ast

0.60
-3.611
0.594
0.169
155

.=(0.87435/100) * (fy/fck)2
.=(0.87/100) * (fy)
.=Mu/bd2
.=-(b(b2-4ac))/2a
.=(p*b*d)/100

0.0899
0.1

DRB
a
b
c
-p
Astlim

0.60
-3.611
3.453
1.194
1096

Mu2
Ast2
Ast

-96
-798
297

.=Mu - Mulim
.=Mu2/((0.87*fy)*(d-d'))
.=Astlim+Ast2

d'/d
fsc
fcc
Asc

0.10
353
11.15
-843

Refer Table F SP 16 pg 13
.=0.466*fck
.=Mu2/((fsc-fcc)*(d-d'))

Min steel %
Ast
Asc

0.205
155
-843

.=0.85% / fy

Min Steel
Max Steel

188
3670

.=(0.85*b*d) / fy
.=0.04*b*d)

Ast
Asc

188

Pt provided
Pc provided

1.315

Shear Calculations

2.208

Shear Capacity of Concrete (Vs)


Shear Stg to be caried by Stirrup (Vus)
Spacing
actual req
min
max
max
X1
(X1+X2)/4

417
363
275
300
184
130

65
-45

.=(Asv*0.87fy*d)/Vus
.=(Asv*0.87fy)/(b*0.4)
.=0.75d
.=300mm

.=c*b*d
.=Vu-Vs
provide the
least of the 6

.=(Ast*100)/(b*d)
.=(Asc*100)/(b*d)
.=(0.8*fck)/(6.89*Pt)

.=(0.87435/100) * (fy/fck)2
.=(0.87/100) * (fy)
.=Mulim/bd2
.=-(b(b2-4ac))/2a
.=(p*b*d)/100

Вам также может понравиться