Вы находитесь на странице: 1из 52

30 | Schco

Schco Fassade USC 65


Schco Faade USC 65

Schco Fassade USC 65


Schco Faade USC 65

Schco | 31

Schco Fassade USC 65


Schco Faade USC 65
SchcoUSC65 (Unitised System
Construction) is a versatile system
solution which offers design
freedom due to its architecturally
sophisticated design options.
SchcoUSC65F, a unitised
faade with a framed look, has
impressive aesthetic standards, as
does Schco USC65FSG, a
semi-structural glazing unitised
faade.

Schco USC 65

Schco USC 65 (Unitized System


Construction) ist eine vielseitige
Systemlsung, die durch seine
architektonisch, anspruchvollen
Designvarianten Gestaltungsfreiheit bietet: Schco USC 65 F,
eine Elementfassade mit Rahmenoptik berzeugt genauso durch
seine sthetischen Ansprche
wie Schco USC 65 FSG, eine
Semi-Structural Glazing-Elementfassade.

32 Systemeigenschaften
System properties
36 Prfzeugnisse
Test certificates
40 Konstruktionsprinzipien
Construction principles
45 Anwendungsbeispiele
Examples
74 Profilbersicht
Overview of profiles

32 | Schco

Systemeigenschaften
System properties

Systemeigenschaften Schco Fassade USC 65


System properties for Schco Faade USC 65
65

10
Schco Fassade USC 65 F
Schco Faade USC 65 F

Mastab 1:1
Scale 1:1

Eigenschaften und Vorteile


Umlaufend schmale Ansichtsbreite bis zu 65 mm
Gestaltungsvarianten:
Rahmenoptik
Semi-Structural Glazing
Variable Elementgliederung durch Sprossen
Senkrechte Sprossen
Waagerechte Sprossen
Gekreuzte Sprossen
Groe Elementabmessungen und
Elementgewichte mglich:
Bautiefen 125 und 150 mm
Statisch optimierte Profilgeometrien
Asymmetrische Eckverbinder fr groe
Glaslasten
Fassadenbefestigung fr Einfeld- und Durchlauftrger
Variable Anpassung an unterschiedliche
Anforderungen an die Wrmedmmung durch
3unterschiedliche Isoliersteglngen
Glasdicken:
Einfachglas von 4 - 16 mm
Isolierglas von 16 - 56 mm
Variables Dichtungsprogramm fr:
10 mm horizontale Stofuge, Aufnahme von
+/- 5 mm Dehnung
20 mm horizontale Stofuge, Aufnahme von
+/- 10 mm Dehnung
Hohe Dichtigkeit durch:
berlappendes Dichtungsprinzip bei
Kopplungs- und Satteldichtung
3-Kammer-Prinzip
System Schco e-connect:
Keine Undichtigkeiten bei der Leitungsfhrung
von innen nach auen
Keine Beschdigung der Leitung beim
Leitungsbergang
Reduzierte Gefahr fehlerhafter elektrischer
Anschlsse durch eindeutige Gewerkeschnittstelle
Einsatzelemente:
Schco AWS 102
Schco AWS 70 BS.HI
Schco AWS 75 BS.HI
Umfangreiche Systemprfungen nach
europischen und amerikanischen Normen

65

10
Schco Fassade USC 65 FSG
Schco Faade USC 65 FSG

Mastab 1:1
Scale 1:1

Features and benefits


All-round narrow face widths (up to 65 mm)
Design types:
Framed look
Semi-structural glazing
Different unit divisions created by glazing bars
Vertical glazing bars
Horizontal glazing bars
Crossed glazing bars
Large unit dimensions and heavy unit weights
possible:
125 mm and 150 mm basic depths
Structurally optimised profile geometries
Asymmetric corner cleats for large glass loads
Faade fixing brackets for single-field and
continuous beams
Can be adjusted to meet different thermal
insulation requirements thanks to 3 different
insulating bar lengths
Glass thicknesses:
Single glazing from 4 - 16 mm
Insulating glass from 16 - 56 mm
Different gaskets for:
10 mm horizontal butt joint, to take up an
expansion of +/- 5 mm
20 mm horizontal butt joint, to take up an
expansion of +/- 5 mm
Excellent weathertightness due to:
Overlapping gasket design for coupling gasket
and saddle gasket
3-chamber principle
Schco e-connect system:
Sealed wiring from inside to outside
No damage to the wiring where cable is
connected
Single connection interface reduces danger of
defective electrical connections
Insert units:
Schco AWS 102
Schco AWS 70 BS.HI
Schco AWS 75 BS.HI
Extensive system tests in accordance with
European and American standards

Schco | 33

Schco USC 65

Systemeigenschaften
System properties

34 | Schco

Systemeigenschaften
System properties

bersicht der Gestaltungsvarianten


Overview of design options
Zur Realisierung unterschiedlicher architektonischer
Entwrfe bietet das System
Schco USC65 interessante
Gestaltungsvarianten: Schco
USC65F als Elementfassade
mit Rahmenoptik sowie Schco
USC65FSG in Ganzglas-Optik
mit horizontal oder vertikal
angeordneten Glasleisten.

Different architectural designs to


be created can be created using
the interesting design options of
the Schco USC 65 system:
Schco USC 65 F as a unitised
faade with framed look and
Schco USC 65 FSG in an allglass look with horizontally or
vertically arranged glazing beads.

Schco USC 65 F Elementfassade mit Rahmenoptik


Schco USC 65 F unitised faade with framed look

Mastab 1:4
Scale 1:4

Schco | 35

Schco USC 65

Systemeigenschaften
System properties

Schco USC 65 FSG Elementfassade mit Semi-Structural Glazing-Optik und horizontaler Betonung
Schco USC 65 FSG unitised faade with semi-structural glazing look and horizontal emphasis

Schco USC 65 FSG Elementfassade mit Semi-Structural Glazing-Optik und vertikaler Betonung
Schco USC 65 FSG unitised faade with semi-structural glazing look and vertical emphasis

Mastab 1:4
Scale 1:4

36 | Schco

Prfzeugnisse
Test certificates

Prfzeugnisse
Test certificates
Art der Prfung
Type of test

Norm
Standard

Prfinstitut
Test institute

Prfzeugnis
Test certificate

Prfergebnis
Test result

Luftdurchlssigkeit
Air permeability

EN 12153

ift-Rosenheim

10835288

AE

Schlagregendichtigkeit
Watertightness

EN 12155

ift-Rosenheim

10835288

RE 1200

Windlast
Wind load

EN 12179

ift-Rosenheim

10835288

1,5 KN/m2
2,25 KN/m2

Stofestigkeit
Impact resistance

EN 13049

ift-Rosenheim

10835288

I5 / E5

Luftschalldmmung
Airborne sound reduction

EN ISO 717-1

ift-Rosenheim

16928386/3

siehe nachfolgende Seite


See following page

Wrmedmmung
Thermal insulation

DIN EN ISO 10077,T2

eigene Berechnung
Own calculation

Absturzsicherheit
(Pendelschlagversuch)
Protection against glass falling out
(Pendulum impact test)

E-TRAV
DIN EN 12600

PSP
RWTH Aachen

auf Anfrage
On request

voll absturzsichernd
Full safety barrier

DIBt

auf Anfrage
On request

siehe Bericht
See report

Allgemeine bauaufsichtliche Zulassung


General building approval

siehe nachfolgende Seite


See following page

Brandschutz / Kaltbrstung
Fire protection/ ventilated spandrel

DIN 4102-3

MPA
Braunschweig

b eantragt
Pending

W90

Air, Water, Structural, Interstory Movement,


Seismic

ASTM E 283-04
ASTM E 331-00
ASTM E 330-02
AAMA 501.4

ATI

81184.02-120-47

siehe Bericht
See report

Prfzeugnisse
Test certificates

Schco | 37

Schallschutz
Sound reduction
Schco-System
Schco system

Prfzeugnis
Test certificate

R45, w = 36 dB

R45, w = 40 dB

Hinweis:
Bei Verwendung von Schallschutzglsern ist darauf zu
achten, da die vom Lieferanten fr das Glas
angegebenen Schalldmmwerte nach der neuesten
Prfnorm ermittelt wurden.

Note:
When using sound reduction glazing, it is important to
ensure that the sound reduction values given by the
supplier have been calculated in accordance with the
most recent test norms.

Empfohlene Verglasung
Recommended glazing

16434412/R1

[6-(16)-6]
andere Glasaufbauten auf
Anfrage
Other glazing configurations
on request

16434412/R1

[6-(12)-9 VSG SF]


andere Glasaufbauten auf
Anfrage
Other glazing configurations
on request

Schco USC 65

Bewertetes Schalldmm-Ma
Airborne sound reduction index

38 | Schco

Prfzeugnisse
Test certificates

Wrmedmmung
Thermal insulation
Schco Fassade USC 65 F
Schco Faade USC 65 F

Uf-Wert in W/m2K nach DIN EN ISO 10077, T2


Uf value in W/m2K in accordance with DIN EN ISO 10077, part 2

mm

25

32,5

42,5
Mastab 1:2
Scale 1:2

mm

125 mm

150 mm

22

3,23

3,27

23 - 30

3,00

3,03

31 - 38

2,91

2,94

30

2,43

2,45

31 - 38

2,27

2,29

39 - 46

2,20

2,23

40

1,91

1,93

41 - 48

1,83

1,84

49 - 56

1,78

1,79

Uf-Wert in W/m2K nach DIN EN ISO 10077, T2


Uf value in W/m2K in accordance with DIN EN ISO 10077, part 2

mm

25

32,5

42,5
Mastab 1:2
Scale 1:2

mm

44 mm

124 mm

149 mm

22

2,71

2,86

2,88

23 - 30

2,64

2,80

2,83

31 - 38

2,63

2,82

2,86

30

2,30

2,42

2,43

31 - 38

2,21

2,33

2,35

39 - 46

2,23

2,37

2,39

40

2,01

2,08

2,09

41 - 48

1,96

2,04

2,06

49 - 56

1,98

2,08

2,10

Prfzeugnisse
Test certificates

Schco | 39

Schco USC 65

Schco Fassade USC 65 FSG


Schco Faade USC 65 FSG

Uf-Wert in W/m2K nach DIN EN ISO 10077, T2


Uf value in W/m2K in accordance with DIN EN ISO 10077, part 2

mm

25

32,5
Mastab 1:2
Scale 1:2

mm

125 mm

150 mm

32

2,67

2,69

33 - 40

2,52

2,54

41 - 48

2,44

2,46

42

2,07

2,08

43 - 50

1,97

1,98

51 - 58

1,95

1,96

Uf-Wert in W/m2K nach DIN EN ISO 10077, T2


Uf value in W/m2K in accordance with DIN EN ISO 10077, part 2

mm

25

32,5
Mastab 1:2
Scale 1:2

mm

44 mm

124 mm

149 mm

32

2,29

2,39

2,41

33 - 40

2,17

2,28

2,30

41 - 48

2,18

2,28

2,29

42

1,99

2,06

2,08

43 - 50

1,91

1,98

2,00

51 - 58

1,90

1,99

2,00

40 | Schco

Konstruktionsprinzipien
Construction principles

Konstruktionsprinzipien
Construction principles
berlappendes Dichtungsprinzip
Overlapping gasket design

Die vertikalen Kopplungsdichtungen werden berlappend


montiert. Die berlappung
erfolgt ber die Satteldichtung
(Elementauenseite) bzw.
ber die horizontale
Kopplungsdichtung
(Elementinnenseite)
Die horizontalen Kopplungsund Satteldichtungen werden
auf der Baustelle ber
mehrere Elemente durchlaufend montiert. Ein eventueller
Satteldichtungssto hat in
Feldmitte zu erfolgen
Die Montage der vertikalen
Kopplungsdichtung erfolgt
bereits einseitig in der
Werkstatt
Zur Ableitung von eventuell
anfallendem Kondensat aus
dem System, wird die Satteldichtung versetzt, auf einer
Breite von 10 mm
eingeschnitten

Schco | 41

The vertical coupling gaskets


are mounted so that they
overlap. They overlap with the
saddle gasket (external side of
unit) or with the horizontal
coupling gasket (internal side
of unit)
The horizontal coupling
gaskets and the saddle
gaskets are mounted
continuously across several
units on the construction site.
Any saddle gasket butt joint
must be positioned in the
centre of the field
The vertical coupling gasket is
already mounted on one side
in the workshop
The saddle gasket is offset
and notched to a width of
10mm to drain any
condensation from the system

Schco USC 65

Konstruktionsprinzipien
Construction principles

42 | Schco

Konstruktionsprinzipien
Construction principles

Verarbeitung und Verglasung Schco USC 65 FSG


Fabrication and glazing for Schco USC 65 FSG

Mastab 1:2
Scale 1:2

Grundstzlich sind bei der Versiegelung und bei der


Structural Glazing-Verklebung bezglich der Haftung
und Vertrglichkeit mit dem Randverbund die
Verarbeitungsrichtlinien der Dichtstofflieferanten
wie Dow Corning oder Sika zu beachten. Ebenso
muss die Vertrglichkeit mit Silikon- und EPDMProfilen sowie Butylbndern gesichert sein.

When sealing and bonding the structural glazing,


observe the guidelines provided by the sealant
supplier, such as Dow Corning or Sika, relating to
adhesion and compatibility with the edge bonding
of the glazing units. It is also important to ensure
compatibility with silicone and EPDM profiles and
butyl tape.

Versiegelung (aussteifend)
Die Versiegelung der Glasfugen muss mit
UV-bestndigem Silikon Klebstoff z.B.
DowCorning993, Dow Corning895, Sikasil
SG-500 oder Sikasil SG-20 erfolgen.
Structural Glazing-Verklebung
Die Structural Glazing-Verklebung muss mit
UV-bestndigem Silikon Klebstoff z.B.
DowCorning993, DowCorning895, Sikasil
SG-500 oder Sikasil SG-20 erfolgen.
Aluminiumoberflche
Die uere Aluminium-Schale des Rahmens
bzw. der Sprosse ist in Eloxaltnen C0 bis C35
ausfhrbar.
Eckausbildung
Im Bereich der Eckausbildung empfiehlt die
Glasindustrie einen dichtstofffreien Falz, um
Kondensat abzuleiten und einen Dampfdruckausgleich nach auen (z.B. ber die Riegel) zu
gewhrleisten. ffnungen in den einzusetzenden
Silikon-Hohlprofilen drfen oben wie unten nicht
verschlossen werden.
Die zu verwendende Glasart ist nach den
jeweils gltigen baurechtlichen Vorschriften
auszuwhlen (ESG, TVG, VSG).
Es sind die technischen Richtlinien fr linienfrmig gelagerte Verglasungen zu beachten.
Die Glaskantenbearbeitung ist mit dem Glaslieferanten abzustimmen.
Ein statischer Nachweis fr die Ganzglasecke
muss erfolgen.
Isolierglas
Es drfen nur Isolierglser mit UV-bestndigen
Randverbund verwendet werden. Alle Kombinationen von Glas, Klebstoff und Vorfller sind
mit den Glas-Klebstoff- und Dichtstofflieferanten
abzustimmen (Gewhrleistung).
Scheibenberstand
Scheibenberstand aus optischen Grnden
abspachteln, bedrucken, etc.

Sealing (reinforcing)
Use a UV-resistant silicone sealing compound,
e.g. DowCorning993, DowCorning895,
SikasilSG-500 or SikasilSG-20, to seal the
glass joints.
Structural glazing bonding
Use a UV-resistant silicone sealing compound,
such as Dow Corning 993, Dow Corning 895,
Sikasil SG-500 or Sikasil SG-20, to bond the
structural glazing.
Aluminium surface
The outer aluminium skin of the frame and the
glazing bar are available in anodised colours C0
to C35.
Corner construction
The glass industry recommends the use of a
sealant-free rebate for corner constructions in
order to channel condensation and to ensure
pressure equalisation with the outside (e.g. via
the transoms). Openings in the silicone hollow
profiles to be inserted must not be closed at the
top or the bottom.
The type of glazing to be used must be selected
in accordance with the relevant construction
regulations (toughened safety glass, partially
toughened safety glass, laminated safey glass).
The technical regulations for overhead glazing
must be observed. The preparation of the glass
edge must be agreed with the glass supplier.
Structural calculations must be supplied for allglass corners.
Insulating glass
Only use insulating glass with UV-resistant edge
seals. All combinations of glass, silicone
adhesive and pre-filler should be agreed with the
glass adhesive and sealant suppliers (warranty).
Glass overlap
The stepped edge unit can either be coated or
ceramic fritted to give a uniform appearance.

Schco | 43

Schco USC 65

Konstruktionsprinzipien
Construction principles

44 | Schco

Konstruktionsprinzipien
Construction principles

Maximale Glaslasten und Elementgren


Maximum glass loads and unit sizes
Einfeldraster
Single module
max. Elementbreite
Max. unit width
max. Elementhhe
Max. unit height
max. Scheibengewicht
Max. pane weight

1350 mm

1350 mm

3600 mm

3600 mm

Profilauswahl
Profile selection

125

150 kg
125 mm

500 kg

150

350 kg

150 mm

Doppelraster
Double module
max. Elementbreite
Max. unit width
max. Elementhhe
Max. unit height
max. Scheibengewicht
Max. pane weight

2700 mm

2700 mm

3600 mm

3600 mm

Profilauswahl
Profile selection

125

125 mm

250 kg

125 kg

125 kg

125 kg

125 kg

250 kg

150

150 mm
Lastabtragung auch ber Sprosse
Load is also transferred to the glazing bar

Anwendungsbeispiele
Examples

Schco | 45

bersicht der Anwendungsbeispiele


Overview of examples
Die hier gezeigten Elementsymbole geben eine bersicht
der mglichen Bauformen. Alle
auf dieser Seite angegebenen
Zahlen sind Seitenzahlen zu den
im Folgenden gezeigten
Anwendungsbeispielen.

The diagrams shown here


provide an overview of the
different shapes that are possible.
The numbers below are the page
numbers for the relevant
examples.

55
56
58
62
63

61

56
57
59
60

52

47
48
49
50
54

46
48
49
50
52
53

Anwendungsbeispiele Schco Fassade USC 65 FSG


Examples Schco Faade USC 65 FSG

73
65
66
67
68
70
71
72

64
66
67
68
69
70
74
73

Schco USC 65

Anwendungsbeispiele Schco Fassade USC 65 F


Examples Schco Faade USC 65 F

51

46 | Schco

Anwendungsbeispiele
Examples

Anwendungsbeispiele Schco Fassade USC 65 F


Examples for Schco Faade USC 65 F
Rahmen mit horizontaler Dehnfuge 10 mm
Frame with 10 mm horizontal expansion gap

24

32

15

125

65

10
Mastab 1:1
Scale 1:1

Schco | 47

10

65

Schco USC 65

Anwendungsbeispiele
Examples

24

32

15

125

48 | Schco

Anwendungsbeispiele
Examples

Rahmen mit horizontaler Dehnfuge 20 mm


Frame with 20 mm horizontal expansion gap

24

32

15

125

65

75

20

10

24

Mastab 1:2
Scale 1:2

32

15

125

Anwendungsbeispiele
Examples

Schco | 49

Rahmen fr groe Elementgewichte mit horizontaler Dehnfuge 10 mm


Frame for large unit weights with 10 mm horizontal expansion gap

24

32

15

125

Schco USC 65

65

10

65

10

24

Mastab 1:2
Scale 1:2

32

15

125

50 | Schco

Anwendungsbeispiele
Examples

Rahmen fr groe Elementgewichte mit horizontaler Dehnfuge 20 mm


Frame for large unit weights with 20 mm horizontal expansion gap

24

32

15

125

65

75

20

10

24

Mastab 1:2
Scale 1:2

32

15

125

Anwendungsbeispiele
Examples

Schco | 51

10

65

24

1.5

1.5

32

15

125

Schco USC 65

Auensegmentierung
External faceting

24

Mastab 1:2
Scale 1:2

32

15

125

52 | Schco

Anwendungsbeispiele
Examples

27.5

10
65

27.5

90 Auenecke
90 outer corner

65

10
91

Mastab 1:2
Scale 1:2

10

Anwendungsbeispiele
Examples

Schco | 53

Schco USC 65

Rahmen mit vertikaler Sprosse


Frame with vertical glazing bar

65

15
21

32

15
32
24
10

Mastab 1:2
Scale 1:2

27.5

124

125

27.5

10

54 | Schco

Anwendungsbeispiele
Examples

27.5

10

Rahmen mit horizontaler E-Sprosse


Frame with horizontal e-glazing bar

32

15

125

21

32

15

124

27.5

10

65

24

Mastab 1:2
Scale 1:2

Anwendungsbeispiele
Examples

Schco | 55

Schco USC 65

Sonnenschutz
Solar shading

Mastab 1:2
Scale 1:2

56 | Schco

Anwendungsbeispiele
Examples

Kaltbrstung mit Einfachglas


Ventilated spandrel with single glazing

32

15

125

65

10

32

15

125

65

10

15

Mastab 1:2
Scale 1:2

Anwendungsbeispiele
Examples

Schco | 57

Schco USC 65

Kaltbrstung der Feuerwiderstandsklasse W90


Ventilated spandrel in fire-resistance class W90

Mastab 1:2
Scale 1:2

58 | Schco

Anwendungsbeispiele
Examples

Fassadenbefestigung und Kaltbrstung der


Feuerwiderstandsklasse W90
Faade fixing bracket and ventilated spandrel
in fire-resistance class W90

A4

70

A4

70

70
70

A4
A4

Mastab 1:4
Scale 1:4

Anwendungsbeispiele
Examples

Schco | 59

Schco USC 65

Seitlicher Baukrperanschluss mit Kaltbrstung der


Feuerwiderstandsklasse W90
Side attachment to building structure with
ventilated spandrel in fire-resistance class W90

Mastab 1:2
Scale 1:2

60 | Schco

Anwendungsbeispiele
Examples

Seitlicher Baukrperanschluss
Side attachment to building structure

Mastab 1:2
Scale 1:2

Anwendungsbeispiele
Examples

Schco | 61

Schco USC 65

Unterer Baukrperanschluss
Bottom attachment to building structure

Mastab 1:2
Scale 1:2

62 | Schco

Anwendungsbeispiele
Examples

10

Fassadenbefestigung und Kaltbrstung mit Einfachglas


Faade fixing bracket and ventilated spandrel with single glazing

Mastab 1:2
Scale 1:2

Anwendungsbeispiele
Examples

Schco | 63

Schco USC 65

Oberer Baukrperabschluss
Top attachment to building structure

Mastab 1:2
Scale 1:2

A4

70

A4

70

A4

70

A4

70

64 | Schco

Anwendungsbeispiele
Examples

Anwendungsbeispiele Schco Fassade USC 65 FSG


Examples for Schco Faade USC 65 FSG
Rahmen mit horizontaler Dehnfuge 10 mm
Frame with 10 mm horizontal expansion gap

36

15

125

65

10
Mastab 1:1
Scale 1:1

Schco | 65

10

65

Schco USC 65

Anwendungsbeispiele
Examples

36

15

125

66 | Schco

Anwendungsbeispiele
Examples

Rahmen mit horizontaler Dehnfuge 20 mm


Frame with 20 mm horizontal expansion gap

36

15

125

65

75

20

10

36

Mastab 1:2
Scale 1:2

15

125

Anwendungsbeispiele
Examples

Schco | 67

Rahmen fr groe Elementgewichte mit horizontaler Dehnfuge 10 mm


Frame for large unit weights with 10 mm horizontal expansion gap

36

15

125

Schco USC 65

65

10

65

10

36

Mastab 1:2
Scale 1:2

15

125

68 | Schco

Anwendungsbeispiele
Examples

Rahmen fr groe Elementgewichte mit horizontaler Dehnfuge 20 mm


Frame for large unit weights with 20 mm horizontal expansion gap

36

15

125

65

75

20

10

36

Mastab 1:2
Scale 1:2

15

125

Anwendungsbeispiele
Examples

Schco | 69

Schco USC 65

Rahmen mit vertikaler Sprosse


Frame with vertical glazing bar

27.5

Mastab 1:2
Scale 1:2

36

15

124

125
15
36
10

27.5

65

10

70 | Schco

Anwendungsbeispiele
Examples

Vertikale Betonung, Dehnfuge 10 mm


Vertical emphasis, 10 mm expansion gap

36

15

125

65

10

65

10

20

Mastab 1:2
Scale 1:2

36

15

125

Anwendungsbeispiele
Examples

Schco | 71

36

15

125

20

36

15

124

27.5

10

65

20

Mastab 1:2
Scale 1:2

Schco USC 65

27.5

Vertikale Betonung, Dehnfuge 10 mm


Vertical emphasis, 10 mm expansion gap

72 | Schco

Anwendungsbeispiele
Examples

Vertikale Betonung, Dehnfuge 20 mm


Vertical emphasis, 20 mm expansion gap

36

15

125

65

20

27.5

10

20

Mastab 1:2
Scale 1:2

36

15

125

Anwendungsbeispiele
Examples

Schco | 73

27.5

Schco USC 65

90 Structural Glazing-Auenecke
90 structural glazing outer corner

65

27.5

Mastab 1:2
Scale 1:2

74 | Schco

Profilbersicht
Overview of profiles

Profilbersicht Schco Fassade USC 65


Overview of profiles for Schco faade USC 65
Rahmenprofile Schco USC 65 F
Schco USC 65 F frame profile

Iy

65

65

198.8

188.8

125

125

125

65

181.3

Ix

cm4

cm4

mm

331 940

177,09

6,85

25

331 950

259,99

7,53

25

331 960

189,4

6,85

32.5

331 970

274,01

7,53

32.5

331 980

207,24

6,85

42.5

331 990

294,16

7,53

42.5

10
10

10

331 940

331 960

331 980

65
65

223.8

206.3

213.8

150

150

150

65

10

10

331 970

331 950

10

331 990

Einschiebprofile
Insert profiles

Iy
Ix

cm4

cm4

338 160

38,63

0,23

351 650

74,29

0,23

9.5

125

85

338 160

351 650

150

110

9.5

Schco | 75

Profilbersicht
Overview of profiles

Verstrkte Rahmenprofile Schco USC 65 F


Schco USC 65 F reinforced frame profiles

Iy

10

65

125

325 410

cm4

cm4

mm

183,51

17,96

25.0

325 420

195,98

17,96

32.5

325 430

214,04

17,96

42.5

325 810

273,42

20,03

25.0

325 820

287,84

20,03

32.5

325 830

308,54

20,03

42.5

188.8

10

65

125

325 420

198.8

10

65

125

325 430

206.3

10

65

150

325 810

213.8

10

65

150

325 820

223.8

325 830

65

10

150

Mastab 1:4
Scale 1:4

Schco USC 65

325 410

181.3

Ix

76 | Schco

Profilbersicht
Overview of profiles

Rahmenprofile Schco USC 65 FSG


Schco USC 65 FSG frame profiles

Iy

325 320
65

cm4

cm4

mm

140,2

6,2

25

325 330

213,49

6,84

25

325 340

147,28

6,2

32.5

325 350

221,56

6,84

32.5

169.5

162

125

125

65

Ix

10

10

325 320

325 340

65

187

194.5

150

150

65

10

10

325 330

325 350

Einschiebprofile
Insert profiles

Iy
Ix

cm4

cm4

338 160

38,63

0,23

351 650

74,29

0,23

9.5

125

85

338 160

351 650

150

110

9.5

Schco | 77

Profilbersicht
Overview of profiles

Verstrkte Rahmenprofile Schco USC 65 FSG


Schco USC 65 FSG reinforced frame profiles

Iy

325 980

162

cm4

cm4

mm

145,9

17,79

25.0

325 990

153,05

17,79

32.5

353 800

224,64

19,83

25.0

353 850

232,92

19,83

32.5

Schco USC 65

10

65

125

Ix

325 980

169.5

10

65

125

325 990

187

10

65

150

353 800

194.5

65

10

150

353 850

Mastab 1:4
Scale 1:4

78 | Schco

Profilbersicht
Overview of profiles

Sprossenprofile Schco USC 65 F


Schco USC 65 F glazing bar profiles

Iy
Ix

cm4

cm4

331 720

59,96

36,46

331 730

308,64

72,48

331 740

441,2

82,06

331 750

72,63

36,46

65
65

100.3

331 720

117.8

107.85

44

44

44

65

331 780

331 750

65
65

331 760

331 730

197.8

180.3

187.8

124

124

124

65

331 790

65
65

331 740

222.8

205.5

212.8

149

149

149

65

331 770

331 800

331 760

331,5

72,48

331 770

467,27

82,06

331 780

91,83

36,46

331 790

364,77

72,48

331 800

504,96

82,06

Schco | 79

Profilbersicht
Overview of profiles

Sprossenprofile Schco USC 65 FSG


Schco USC 65 FSG glazing bar profiles

Iy

cm4

cm4

331 830

39,45

35,23

331 840

258,01

71,24

331 850

378,02

80,82

331 860

47,99

35,23

331 870

273,97

71,24

331 880

396,49

80,82

124

65

65

81.05

88.55

44

44

161

65

331 860

331 830

331 840

65
65

331 850

331 870

193.5

168.55

186

124

149

149

64.7

331 880

Sprossen Einschiebprofil
Glazing bar insert profile

Iy
Ix

59

cm4

240,93

39,57

149

125

351 620

cm4

351 620

Mastab 1:4
Scale 1:4

Schco USC 65

Ix

80 | Schco

Profilbersicht
Overview of profiles

E-Sprossenprofile Schco USC 65 F


Schco USC 65 F e-glazing bar profiles

Iy
Ix
65

65

cm4

cm4

331 890

284,3

74,96

331 900

307,06

74,96

331 910

340,23

74,96

331 890

196.2

178.7

186.2

122.35

122.4

122.4

64.9

331 900

331 910

E-Sprossenprofile Schco USC 65 FSG


Schco USC 65 FSG e-glazing bar profiles

Iy
Ix

65

159.4

166.9

122.4

122.4

64.9

331 920

331 930

Deckschale fr E-Sprossenprofil
Cover cap for e-glazing bar profile
65

336 950

203 022

cm4

cm4

331 920

234,19

73,73

331 930

250,09

73,73

Schco | 81

Profilbersicht
Overview of profiles

Eckpfosten
Corner mullions

Iy
Ix
65

cm4

33

cm4

236,91

21,37

338 060

1146,74

116,46

225.5

Schco USC 65

80

102

324 330

324 330

338 060

53

.5

91

46

15

Glasleisten fr 90 Auenecke
Glazing beads for 90 outer corner

325 690

325 680

12

325 360

12

27.5

27.5

27.5

27.5

Glasleisten
Glazing beads

15

307 060*

325 280

15

307 070*

* Nur fr Eloxal geeignet


Only suitable for anodising

Abdeckprofile fr horizontale Betonung


Cover profiles for horizontal emphasis
19

336 450

80

70

19

336 490

Mastab 1:4
Scale 1:4