Commissioning procedure
Visual inspection of BTSE
Reset CCTRL
Download BTSE software
Activate BTSE software
Set rack
Create hardware related managed objects
CREATE ENVABTSE
Set attributes for BTS site equipment
Creation of Bport
Enter BTS site manager attributes
LAPDLE creation
Verify module state/status
Manually switch to phase three
Generate backup files
BTSE restart verification
Functional structure
Exercises
MN1784EU12MN_0001
2002 Siemens AG
3
7
11
15
21
25
29
32
33
34
36
38
41
43
45
49
53
59
Siemens
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Commissioning procedure
MN1784EU12MN_0001
2002 Siemens AG
Siemens
BTSE commissioning
To bring-up the BTSE, follow the "Procedures" chapter in the ITMN:BTSE BS XX.
In the CML:BTSE you will find more information about the meaning of specific
attributes.
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Reset CCTRL
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Siemens
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
MN1784EU12MN_0001
2002 Siemens AG
Siemens
BTSE commissioning
Visually inspect the BTSE mechanics, electrics and modules. Follow the appropriate
chapters in the ITMN:BTSE BS XX.
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
CB
FP
A
C
O
M
A
C
O
M
A
C
O
M
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
P T P T P T P T P T P T P T
A P A P A P A P A P A P A P
U
U
U
U
U
U
U
D
C
P
A
D
C
T
P
U
B
B
S
I
G
B
B
S
I
G
D
C
P
A
B
B
S
I
G
D
C
T
P
U
B
B
S
I
G
D
C
P
A
B
B
S
I
G
B
B
S
I
G
D
C
T
P
U
D
C
P
A
M
C
L
K
D
C
T
P
U
D
C
P
A
C
C
T
R
L
D
C
T
P
U
L
I
D
C
T
P
U
D
C
P
A
A
L
C
O
GPSU
FANS
AIR FILTER
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Siemens
10
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Reset CCTRL
MN1784EU12MN_0001
2002 Siemens AG
11
BTSE commissioning
Siemens
12
RY: green
RBM: red
ACT: yellow
PRGA: off
SPA1: off
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
CCTRL
TAD
LED green
RY
RBM
LED red
LED yellow
ACT
PRGA
LED red
LED green
SPA 1
SPA 2
LED green
Pushbutton
RES
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
Siemens
14
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
MN1784EU12MN_0001
2002 Siemens AG
15
BTSE commissioning
Siemens
In BTSE phase 1 only very few commands are available. One of them is
DNLALLEXE:
LMT tree:
Command:
DNLALLEXE
Name:
none
Attributes:
Submit
Command line:
DNLALLEXE:SRCDIR="<path where the SW Load is stored on the LMT>",
HEADER="HSxxxxxx.swl", OVERWRITE=YES;
The result is a complete SW download, on LMT the load progress in % is indicated.
The entire procedure requires about ca 10 minutes.
During the download procedure the CCTRL PRGA LED is flashing.
Check during downloading whether all BTSE executable files (*.swi files) are
successfully transferred.
16
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
17
BTSE commissioning
Siemens
SW Image
Description
Module
btsarc01.swi
TPU/TRXA
btsdrx01.swi
TPU/TRXD
btsdrx03.swi
TPU/TRXD2
btsbbx01.swi
BBSIG
btsbbx03.swi
BBSIG44
btsbmc01.swi
CCTRL
btscac01.swi
ALCO
btscck01.swi
common clock
CCLK
btslic01.swi
LI
btslic04.swi
LI
18
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
download software
LMT
Fig. 5 Download BTSE software
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
19
Siemens
20
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
MN1784EU12MN_0001
2002 Siemens AG
21
BTSE commissioning
Siemens
Command:
ACTIVATE BTSM
Name:
NAME=BTSM:0
Attributes:
Submit
Command line:
ACTSW BTSM:NAME=BTSM:0,FID=<Name of the Software Load Header file:
HSxxyyzz.SWL>, FV=<Software Load Header: SS-VV-RR-PR-LL-CL_Year-MonthDay
This procedure requires about 1 minute.
The BTSE switches from phase 1 to phase 2 and therefore a new Logon is
necessary.
22
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
activate software
RAM of Processors
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
Siemens
24
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Set rack
MN1784EU12MN_0001
2002 Siemens AG
25
BTSE commissioning
Siemens
To enter the rack attributes, perform the following steps from LMT:
LMT tree:
Command:
SET RACK
Name:
NAME=RACK:0
Attributes:
BATTBAK=<installed or not_installed>
TYPBTSE=BSxx
TYPRFSR=<Type of RF Subrack: horizontal or vertical>
Submit
Command line:
SET RACK:NAME=RACK:0,BATTBAK=<installed or not_installed>,TYPBTSE=BSxx,
TYPRFSR=<Type of RF Subrack: horizontal or vertical>;
BA TTBAK
TYPBTSE
TYPRFSR
Rack attributes
26
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
27
Siemens
28
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
MN1784EU12MN_0001
2002 Siemens AG
29
BTSE commissioning
Siemens
The CCTRL is the only module, which is created automatically by the system. All
other modules have to be created by manually. Creating these so called hardware
related managed objects means that the modules are defined in the local database of
the BTSE, which is stored on the CCTRL Flash EPROM.
For each BTSE up to 14 different types of hardware related managed objects have to
be created.
For each module (type), which is equipped in the specific BTSE you are just
commissioning, perform the following steps from the LMT:
LMT tree:
Command:
CREATE Module
Name:
NAME=RACK:0/Module:<Module Number>
Attributes:
Submit
Command line:
CREATE Module:NAME=NAME=RACK:0/Module:<Module Number>,Attributes
According to this scheme, create all the modules, which are equipped in the specific
BTSE you are just commissioning. Refer to the corresponding procedure in the
ITMN:BTSE BS XX.
The following table summarizes the different types of possible managed objects.
Refer to the customer specific documentation in order to determine the managed
objects, which need to be created for the site.
30
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Module
Parameter range
ACOM/TXAMOD
0...2
ALCO
BBSIG
0...5
CCLK
FAN
0...2
GPSU
LI
PA
0...5
RXAMOD
0...5
RXMUCO/RXAMCO
0...7
TPU
0...5
AC_DC
FICOM_VSWR
0...2
FICOM_TNF
0...5
MN1784EU12MN_0001
2002 Siemens AG
31
BTSE commissioning
Siemens
7.1
CREATE ENVABTSE
Command:
CREATE ENVABTSE
Name:
Attributes:
INTINF=<interfaceInformation>
ASEV=<associatedSeverity>
ASTRING=<associatedString>
Submit
Command line:
CREATE ENVABTSE:NAME=RACK:0/ENVABTSE:<Number of environmental
alarm>, INTINF=<interfaceInformation>, ASEV=<associatedSeverity>,
ASTRING=<associatedString>
Number of environmental alarm
associatedSeverity
associatedString
interfaceInformation
32
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
7.2
Siemens
locationName
vendorName
swLoadSafety
salesUniqueName
With the help of this attribute a sales unique name can be set.
This sales unique name must be a string with min = max = 11
characters.
MN1784EU12MN_0001
2002 Siemens AG
33
BTSE commissioning
Siemens
7.3
Creation of Bport
Before the BTSM attributes can be set, the Bports must be created. The range of
possible values for BS2x/6x is "0,2"
A layer1 control timeslot (16 kbit/s) is needed when the line configuration is "loop" or
when two PCMB lines are connected to the BTSE. These two configurations are
mutually exclusive.
34
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
35
BTSE commissioning
Siemens
7.4
Here, the attributes of the BTS_Site_Manager (BTSM) are set. The BTS Site
Manager represents the O&M functionality related to a site and not to any specific
BTS. A site is a logical grouping of one or more BTS (maximum 3) at a single
physical location with common management needs. This configuration has to match
with the related LPDLM-Object in the BSC.
Note: the LAPD signaling on BTSM must terminate on Bport 0.
ABISTIME
ABISCH
TEI
36
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
37
BTSE commissioning
Siemens
7.5
LAPDLE creation
The object LAPDLE identifies the time slot on Abis used for communication between
BSC and BTSE (as viewed from BTSE). Its counterpart on the BSC side is called
"LPDLM".
It is possible to configure up to 8 LAPDLE/LPDLM objects on two PCMB lines. Each
line must carry at least one LAPDLE/LPDLM.
The LAPD links are either all 64 kbit/s (3 and more TRX per BTSE) or all 16 kbit/s
(max 2 TRX/BTSE), and either all satellited or all not satellited.
Note:
The object "LPDLM" on the BSC command tree indicates a time slot, which may
carry both LPDLM and LPDLR type LAPD signaling.
The settings for LAPDLE (BTSE commissioning) and LPDLM (BSC database) must
be consistent.
38
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
39
Siemens
40
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
MN1784EU12MN_0001
2002 Siemens AG
41
BTSE commissioning
Siemens
Check the state and status of all the hardware modules created. For all successfully
created objects the administrative state must be unlocked and the operational state
must be enabled.
From LMT, perform the following steps:
LMT tree:
Command:
Name:
NAME=RACK:0/<Module Name>
Attributes:
REQATTL=AST&OST
Submit
Command line:
GET Module:NAME=RACK:0/<Module Name>, REQATTL=AST&OST;
42
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
MN1784EU12MN_0001
2002 Siemens AG
43
BTSE commissioning
Siemens
For forced switchover to phase three a special command (connect BSC to BTSM
command) must be entered at the LMT.
LMT tree:
Command:
CONNBSC BTSM
Name:
NAME=BTSM:0
Attributes:
none
Submit
Command line:
CONNBSC BTSM:NAME=BTSM:0;
To unlock the BTSM, perform the following steps from LMT:
LMT tree:
Command:
UNLOCK BTSM
Name:
NAME=BTSM:0
Attributes:
none
Submit
Command line:
UNLOCK BTSM:NAME=BTSM:0;
44
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
MN1784EU12MN_0001
2002 Siemens AG
45
Siemens
BTSE commissioning
In order to save the latest BTSplus configuration, a backup copy is generated and
stored on site, e.g. on a floppy disk.
By default; all files necessary to perform the backup and restore procedure are
stored in subdirectory C:/Siemens/LMTxxx/BkBts/BTSplusyy on the LMT hard disk
(where yy can be 16, 17 or 18 to indicate BR7.0, BR8.0 or BR9.0 SW version used in
the BTS, respectively).
BTSplus backup files are generated in phase 2 or 3 by performing the following
steps:
46
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
MN1784EU12MN_0001
2002 Siemens AG
47
Siemens
48
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
MN1784EU12MN_0001
2002 Siemens AG
49
Siemens
BTSE commissioning
Power off and on the BTSE to ensure that the BTSE recovers without errors in case
of a total loss of power.
50
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
CB
FP
A
C
O
M
A
C
O
M
A
C
O
M
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
R
X
M
U
C
P T P T P T P T P T P T P T
A P A P A P A P A P A P A P
U
U
U
U
U
U
U
D
C
P
A
D
C
T
P
U
D
C
P
A
B
B
S
I
G
B
B
S
I
G
B
B
S
I
G
D
C
T
P
U
B
B
S
I
G
D
C
P
A
B
B
S
I
G
B
B
S
I
G
D
C
T
P
U
D
C
P
A
M
C
L
K
D
C
T
P
U
D
C
T
P
U
D
C
P
A
C
C
T
R
L
L
I
D
C
P
A
D
C
T
P
U
A
L
C
O
GPSU
FANS
AIR FILTER
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
51
Siemens
52
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
12 Functional structure
Cell 0
Abis
LI 0
DUKIT
fx (2:1)
PA 0
DUKIT
0
TPU 0
MSG 0
TPU 1
BBSIG 0
BUS 1
PA 1
RXAMCO
1
BUS 2
DCTPU
0
MCUX 0
DCTPU
1
ALCO 0
DCPA
0
ALCO 0
RXAMCO
1
LMT
Site Inputs
Site Outputs
DCPA
1
FAN 0
-48 V
GPSU 0
Backup
Battery
DC
Breaker
AC/DC 0
PDB
230 V AC
...Diversity
Fig. 17 Functional blocks of a 2 carrier BTSE (BS20) with DUKIT (configured for 1 cell with 2 carriers)
MN1784EU12MN_0001
2002 Siemens AG
53
BTSE commissioning
Siemens
Link
Equipment
Abis
Cell 0
LI 0
DUKIT
fx (2:1)
0
PA 0
DUKIT 0
TPU 0
MCLK 0
TPU 1
BBSIG 1
0
RXAMCO
1
0
DCTPU 0
BUS 1
PA 1
BUS 2
MCLK 0
0
RXAMCO
1
CCTRL 0
DCTPU 1
LMT
Site Inputs
DCPA 1
ALCO 0
Site Outputs
DCPA 1
AC/DC 0
FAN 0
DC
-48 V Breaker
GPSU 0
Backup
Battery
HOST
EXCHANGE
HOSTER
PDB
230 V AC
AC/DC 1
...Diversity
Fig. 18 Functional blocks of a 2 carrier BTSE (BS21E) with DUKIT (configured for 1 cell with 2 carriers)
54
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Abis
LI
PA
TPU
DUCOMT
BUS 1
BUS 2
BBSIG
CCLK
RXAMCO
CCTRL
RXAMCO
LMT
ALCO
FCB 0
...Diversity
230V AC
FP
ACMDC
Fig. 19 Functional blocks of a 2 carrier BTSE (BS22) with DUCOMT (configured for 1 cell with 2 carriers)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
55
BTSE commissioning
Siemens
Abis
(OVPT, NTPM or Wave)
LI
PA
TPU
BBSIG
BUS 2
HYCOM
BUS 1
RXAMOD
CCLK
RXMUCO
CCTRL
LMT
RXAMOD
Site Inputs
RXMUCO
ALCO
FAN 2
...Diversity
FAN 1
DCPA
DCTPU
GPSU
Site Outputs
FP
-48 V DC
FAN 0
Fig. 20 Functional blocks of a 6 carrier BTSE with HYCOM (configured for 1 cell with 4 carriers)
56
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Abis
LI
PA
TPU
BBSIG
BUS 2
DLCOM
BUS 1
CCLK
RXAMCO
CCTRL
LMT
Site
RXAMCO
Input
...Diversity
ALCO
Site
Output
FAN 2
DCPA
DCTPU
-48 V DC
FAN 1
GPSU
FP
FAN 0
Fig. 21 Functional blocks of a 6 carrier BTSE with DUCOM (configured for 1 cell with 4 carriers)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN1784EU12MN_0001
2002 Siemens AG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
57
BTSE commissioning
Siemens
Abis
PA
LI
TPU
FICOM
BBSIG
RXAMCO
BUS 2
RXFIL
RXFIL
CCLK
BUS 1
RXMUCO
RXAMCO
CCTRL
LMT
RXMUCO
Site Inputs
ALCO
FAN 2
...Diversity
DCPA
Site Outputs
DCTPU
-48 V DC
FAN 1
GPSU
FP
FAN 0
Fig. 22 Functional blocks of a 6 carrier BTSE with FICOM (configured for 1 cell with 6 carriers)
58
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
13 Exercises
MN1784EU12MN_0001
2002 Siemens AG
59
Siemens
60
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Exercise 1
Commission a BTSE in the Training Center. Remember, in the Training Center you
will find an already running system. Therefore, before you follow chapters 1, 2 and 3
of this register, you have to do some previous work and to add some additional steps
in order to bring the system down.
Previous work to be done:
Write down the name of the software load header file and the software load header
itself for the BTSE. Take a look to the subdirectory containing the BTSE
software on your LMT hard disk. Compare it with the information in the BSC
database.
With which command can you display the currently running software on the BTSE?
Find out the configuration (star, loop or multidrop chain) of the BTSE.
Find out the TEI and SalesUniqueName of the BTSE.
Find out which timeslot is used for LAPD signaling.
Find out whether a 64 kbit/s or a 16 kbit/s timeslot is used for LAPD signaling.
Find out whether or not CRC is used.
Find out whether or not environmental alarms have to be equipped.
Usually find out means: ask your boss or your colleagues. Since we have a running
system in the Training Center you can also interrogate the system itself. Therefore
use the following commands from LMT:
LMT tree:
Command:
GET BTSE
Name:
NAME=BTSE:0
Attributes:
Submit
Command line:
GET BTSE SWL: NAME=BTSE:0, REQATTL= SWLDINT, SWLDSAF,
SWLDST;
MN1784EU12MN_0001
2002 Siemens AG
61
BTSE commissioning
Siemens
LMT tree:
Command:
GET BTSM
Name:
NAME=BTSM:0
Attributes:
Submit
Command line:
GET BTSM: NAME=BTSM:0, REQATTL= ABISCH, TEI;
LMT tree:
Command:
GET LI
Name:
NAME=RACK:0/LI:0
Attributes:
Submit
Command line:
GET LI: NAME=RACK:0/LI:0, REQATTL= REQATTL= BERT, LCONF, ALRMT1/2/3,
ALRMCOUNTER;
62
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Exercise 2
Additional steps in order to bring the system down
I) Lock BTSM and disconnect (by command) BTSE from BSC
From LMT, enter the following commands:
LMT tree:
Command:
LOCK BTSM
Name:
NAME=BTSM:0
Attributes:
none
Submit
Command line:
LOCK BTSM: NAME=BTSM:0;
LMT tree:
Command:
DISCBSC
Name:
NAME=BTSM:0;
Attributes:
none
Submit
Command line:
DISCBSC BTSM: NAME=BTSM:0;
BTSE switches from phase 3 to phase 2. A new Logon is necessary.
MN1784EU12MN_0001
2002 Siemens AG
63
Siemens
64
BTSE commissioning
MN1784EU12MN_0001
2002 Siemens AG
BTSE commissioning
Siemens
Exercise 3
I) Format CCTRL Flash EPROM
From LMT, perform the following steps:
LMT tree:
Command:
Name:
NAME=BTSE:0;
Attributes:
none
Submit
Command line:
FORMAT BTSE FLASH: NAME=BTSE:0;
This procedure requires about 1-2 minutes.
The BTSE switches from phase 2 to phase 1. A new Logon is necessary.
II) Power off the BTSE
Switch off all fuses.
Follow now chapters 1, 2 and 3 of this register to commission the BTSE.