BTSE commissioning

Siemens

BTSE commissioning

Contents
1
2
3
4
5
6
7
7.1
7.2
7.3
7.4
7.5
8
9
10
11
12
13

Commissioning procedure
Visual inspection of BTSE
Reset CCTRL
Download BTSE software
Activate BTSE software
Set rack
Create hardware related managed objects
CREATE ENVABTSE
Set attributes for BTS site equipment
Creation of Bport
Enter BTS site manager attributes
LAPDLE creation
Verify module state/status
Manually switch to phase three
Generate backup files
BTSE restart verification
Functional structure
Exercises

MN1784EU12MN_0001
2002 Siemens AG

3
7
11
15
21
25
29
32
33
34
36
38
41
43
45
49
53
59

Siemens

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Commissioning procedure

MN1784EU12MN_0001
2002 Siemens AG

Siemens

BTSE commissioning

To bring-up the BTSE, follow the "Procedures" chapter in the ITMN:BTSE BS XX.
In the CML:BTSE you will find more information about the meaning of specific
attributes.

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Reset CCTRL

Download BTSE Software

Activate BTSE Software

Set Rack Attributes

Create Hardware Related


Managed Objects
Set Environmental Alarms
and BTS Site Equipment

Create Bport and Xconnect

Enter BTS Site Manager


Attributes
Verify Module
State/Status
Manually Switch
to Phase Three

Fig. 1 BTSE bring-up

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Siemens

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Visual inspection of BTSE

MN1784EU12MN_0001
2002 Siemens AG

Siemens

BTSE commissioning

Visually inspect the BTSE mechanics, electrics and modules. Follow the appropriate
chapters in the ITMN:BTSE BS XX.

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

CB

FP

A
C
O
M

A
C
O
M

A
C
O
M

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

P T P T P T P T P T P T P T
A P A P A P A P A P A P A P
U
U
U
U
U
U
U

D
C
P
A

D
C
T
P
U

B
B
S
I
G

B
B
S
I
G

D
C
P
A

B
B
S
I
G

D
C
T
P
U

B
B
S
I
G

D
C
P
A

B
B
S
I
G

B
B
S
I
G

D
C
T
P
U

D
C
P
A

M
C
L
K

D
C
T
P
U

D
C
P
A

C
C
T
R
L

D
C
T
P
U

L
I

D
C
T
P
U

D
C
P
A

A
L
C
O
GPSU

FANS
AIR FILTER

Fig. 2 Visual inspection of BTSE

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Siemens

10

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Reset CCTRL

MN1784EU12MN_0001
2002 Siemens AG

11

BTSE commissioning

Siemens

Press the small black push button on the CCTRL board.


After about 15 seconds the CCTRL reaches the start connection status.
LED Indication of CCTRL:

12

RY: green

RBM: red

ACT: yellow

PRGA: off

SPA1: off

SPA2: green, flashing

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

CCTRL

TAD

LED green

RY

RBM

LED red

LED yellow

ACT

PRGA

LED red

LED green

SPA 1

SPA 2

LED green

Pushbutton

RES

Fig. 3 CCTRL front plate with LED and reset button

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

13

Siemens

14

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Download BTSE software

MN1784EU12MN_0001
2002 Siemens AG

15

BTSE commissioning

Siemens

In BTSE phase 1 only very few commands are available. One of them is
DNLALLEXE:
LMT tree:

MANAGED-ELEMENT --> SOFTWARE-MANAGEMENT

Command:

DNLALLEXE

Name:

none

Attributes:

SCRDIR=<path where the SW Load is stored on the LMT>


HEADER=<enter header according to the SW Load e.g.:
HSxxxxxx.SWL>
OVERWRITE=YES

Submit
Command line:
DNLALLEXE:SRCDIR="<path where the SW Load is stored on the LMT>",
HEADER="HSxxxxxx.swl", OVERWRITE=YES;
The result is a complete SW download, on LMT the load progress in % is indicated.
The entire procedure requires about ca 10 minutes.
During the download procedure the CCTRL PRGA LED is flashing.
Check during downloading whether all BTSE executable files (*.swi files) are
successfully transferred.

16

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Fig. 4 Software download to BTSE

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

17

BTSE commissioning

Siemens

SW Image

Description

Module

btsarc01.swi

analog radio controller

TPU/TRXA

btsdrx01.swi

digital radio controller

TPU/TRXD

btsdrx03.swi

digital radio controller

TPU/TRXD2

btsbbx01.swi

baseband and signaling processors

BBSIG

btsbbx03.swi

baseband and signaling processors

BBSIG44

btsbmc01.swi

base station master controller

CCTRL

btscac01.swi

central alarm controller

ALCO

btscck01.swi

common clock

CCLK

btslic01.swi

link interface controller

LI

btslic04.swi

link interface controller

LI

BTSE executable files

18

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

download software

CCTRL Flash EPROM

LMT
Fig. 5 Download BTSE software

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

19

Siemens

20

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Activate BTSE software

MN1784EU12MN_0001
2002 Siemens AG

21

BTSE commissioning

Siemens

From LMT perform the following steps:


LMT tree:

MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTS --> BTSM

Command:

ACTIVATE BTSM

Name:

NAME=BTSM:0

Attributes:

FID=<Name of the Software Load Header file: HSxxyyzz.SWL>


FV=<Software Load Header: SS-VV-RR-PR-LL-CL_Year-Month-Day

Submit
Command line:
ACTSW BTSM:NAME=BTSM:0,FID=<Name of the Software Load Header file:
HSxxyyzz.SWL>, FV=<Software Load Header: SS-VV-RR-PR-LL-CL_Year-MonthDay
This procedure requires about 1 minute.
The BTSE switches from phase 1 to phase 2 and therefore a new Logon is
necessary.

22

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Fig. 6 Activate BTSM

activate software

CCTRL Flash EPROM

RAM of Processors

Fig. 7 Activate BTSE software

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

23

Siemens

24

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Set rack

MN1784EU12MN_0001
2002 Siemens AG

25

BTSE commissioning

Siemens

To enter the rack attributes, perform the following steps from LMT:
LMT tree:

MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK

Command:

SET RACK

Name:

NAME=RACK:0

Attributes:

BATTBAK=<installed or not_installed>
TYPBTSE=BSxx
TYPRFSR=<Type of RF Subrack: horizontal or vertical>

Submit
Command line:
SET RACK:NAME=RACK:0,BATTBAK=<installed or not_installed>,TYPBTSE=BSxx,
TYPRFSR=<Type of RF Subrack: horizontal or vertical>;

BA TTBAK

This attribute indicates whether or not a battery backup is installed.

TYPBTSE

This attribute identifies the type of BTSE. Validity range: BS20,


BS21E, BS60, BS61E, BS22.

TYPRFSR

This attribute identifies the type of the RF subrack. Validity range:


RF_SUBRACK_V1 (horizontal design), RF_SUBRACK_V2
(vertical design).

Rack attributes

26

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Fig. 8 Set rack attributes

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

27

Siemens

28

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Create hardware related managed objects

MN1784EU12MN_0001
2002 Siemens AG

29

BTSE commissioning

Siemens

The CCTRL is the only module, which is created automatically by the system. All
other modules have to be created by manually. Creating these so called hardware
related managed objects means that the modules are defined in the local database of
the BTSE, which is stored on the CCTRL Flash EPROM.
For each BTSE up to 14 different types of hardware related managed objects have to
be created.
For each module (type), which is equipped in the specific BTSE you are just
commissioning, perform the following steps from the LMT:
LMT tree:

MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK -->


Module

Command:

CREATE Module

Name:

NAME=RACK:0/Module:<Module Number>

Attributes:

depending on the module type

Submit
Command line:
CREATE Module:NAME=NAME=RACK:0/Module:<Module Number>,Attributes
According to this scheme, create all the modules, which are equipped in the specific
BTSE you are just commissioning. Refer to the corresponding procedure in the
ITMN:BTSE BS XX.
The following table summarizes the different types of possible managed objects.
Refer to the customer specific documentation in order to determine the managed
objects, which need to be created for the site.

30

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Module

Parameter range

ACOM/TXAMOD

0...2

ALCO

BBSIG

0...5

CCLK

FAN

0...2

GPSU

LI

PA

0...5

RXAMOD

0...5

RXMUCO/RXAMCO

0...7

TPU

0...5

AC_DC

FICOM_VSWR

0...2

FICOM_TNF

0...5

List of the hardware related managed objects

Fig. 9 Example: Creation of ACOM (wiring data)

MN1784EU12MN_0001
2002 Siemens AG

31

BTSE commissioning

Siemens

7.1

CREATE ENVABTSE

To configure external alarms perform the following steps from LMT:


LMT tree:

MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK -->


ENVABTSE

Command:

CREATE ENVABTSE

Name:

NAME=RACK:0/ENVABTSE:<Number of environmental alarm>

Attributes:

INTINF=<interfaceInformation>
ASEV=<associatedSeverity>
ASTRING=<associatedString>

Submit
Command line:
CREATE ENVABTSE:NAME=RACK:0/ENVABTSE:<Number of environmental
alarm>, INTINF=<interfaceInformation>, ASEV=<associatedSeverity>,
ASTRING=<associatedString>
Number of environmental alarm

This attribute selects one of the 20 possible


environmental alarms. Validity range: 0 - 19.

associatedSeverity

This attribute allows the operator to define a


specific severity level for the failure event report
related to an environmental alarm. Validity range:
CRITICAL, MAJOR, MINOR, WARNING.

associatedString

This attribute allows the operator to define a


specific text string for the failure event report
related to an environmental alarm. Validity range:
STRING with max. 26 ASCII characters.

interfaceInformation

Depending on the type of external alarm sensor


this attribute must be set to high for a break
contact (normal closed) or to low for a make
contact (normal open).

Attributes of BTSE environmental alarms

32

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

7.2

Siemens

Set attributes for BTS site equipment

Fig. 10 Set BTSE attributes

locationName

This attribute identifies a location. Validity range: a string of 1


to n, n = 37 characters (default: EARTH).

vendorName

This attribute identifies the vendor of the associated object.


Validity range: a string of 1 to n, n = 37 characters (default:
SIEMENS).

swLoadSafety

This attribute describes the file ID and the version number of


the SW Load stored in the BTSE as the most trusted SW load
that is used if the intended SW is damaged in some way.

salesUniqueName

With the help of this attribute a sales unique name can be set.
This sales unique name must be a string with min = max = 11
characters.

Important BTS site equipment attributes

MN1784EU12MN_0001
2002 Siemens AG

33

BTSE commissioning

Siemens

7.3

Creation of Bport

Before the BTSM attributes can be set, the Bports must be created. The range of
possible values for BS2x/6x is "0,2"
A layer1 control timeslot (16 kbit/s) is needed when the line configuration is "loop" or
when two PCMB lines are connected to the BTSE. These two configurations are
mutually exclusive.

34

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Fig. 11 Creation of Bport

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

35

BTSE commissioning

Siemens

7.4

Enter BTS site manager attributes

Here, the attributes of the BTS_Site_Manager (BTSM) are set. The BTS Site
Manager represents the O&M functionality related to a site and not to any specific
BTS. A site is a logical grouping of one or more BTS (maximum 3) at a single
physical location with common management needs. This configuration has to match
with the related LPDLM-Object in the BSC.
Note: the LAPD signaling on BTSM must terminate on Bport 0.
ABISTIME

This attribute provides the time-of-day time of the BTSE. This


attribute functions as a reference for all time stamp activities in the
BTSE. Validity range: Year 1000-9999, Month 1-12, Day 1-31, Hour
0-23, Minute 0-59, Second 0-59.

ABISCH

This attribute identifies the LAPD signaling Timeslot Number (and


Subslot Number) allocated on the Abis-interface. Validity range:
Timeslot_Number: 1-31 (PCM30), 1-24 (PCM24). Subslot Number: a
(bits 1,2)=0, b (bits 3,4)=1, c (bits 5,6)=2, d (bits 7,8)=3, 64 kb/s
signal.=0xFF.

TEI

This attribute contains the Terminal Endpoint Identifier used in the


layer2 addressing on the Abis-Interface for the logical O&M Link.
The TEI is used to identify a specific point-to-point connection; each
BTSM normally has one associated TEI. Validity range: 0-63.

BTS site manager attributes

36

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Fig. 12 Set BTSM attributes

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

37

BTSE commissioning

Siemens

7.5

LAPDLE creation

The object LAPDLE identifies the time slot on Abis used for communication between
BSC and BTSE (as viewed from BTSE). Its counterpart on the BSC side is called
"LPDLM".
It is possible to configure up to 8 LAPDLE/LPDLM objects on two PCMB lines. Each
line must carry at least one LAPDLE/LPDLM.
The LAPD links are either all 64 kbit/s (3 and more TRX per BTSE) or all 16 kbit/s
(max 2 TRX/BTSE), and either all satellited or all not satellited.
Note:
The object "LPDLM" on the BSC command tree indicates a time slot, which may
carry both LPDLM and LPDLR type LAPD signaling.
The settings for LAPDLE (BTSE commissioning) and LPDLM (BSC database) must
be consistent.

38

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Fig. 13 LAPDLE creation

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

39

Siemens

40

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Verify module state/status

MN1784EU12MN_0001
2002 Siemens AG

41

BTSE commissioning

Siemens

Check the state and status of all the hardware modules created. For all successfully
created objects the administrative state must be unlocked and the operational state
must be enabled.
From LMT, perform the following steps:
LMT tree:

MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK -->


<module>

Command:

GET <Module Name>

Name:

NAME=RACK:0/<Module Name>

Attributes:

REQATTL=AST&OST

Submit
Command line:
GET Module:NAME=RACK:0/<Module Name>, REQATTL=AST&OST;

42

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Manually switch to phase three

MN1784EU12MN_0001
2002 Siemens AG

43

BTSE commissioning

Siemens

For forced switchover to phase three a special command (connect BSC to BTSM
command) must be entered at the LMT.
LMT tree:

MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTS --> BTSM

Command:

CONNBSC BTSM

Name:

NAME=BTSM:0

Attributes:

none

Submit
Command line:
CONNBSC BTSM:NAME=BTSM:0;
To unlock the BTSM, perform the following steps from LMT:
LMT tree:

MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTSM -->

Command:

UNLOCK BTSM

Name:

NAME=BTSM:0

Attributes:

none

Submit
Command line:
UNLOCK BTSM:NAME=BTSM:0;

44

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

10 Generate backup files

MN1784EU12MN_0001
2002 Siemens AG

45

Siemens

BTSE commissioning

In order to save the latest BTSplus configuration, a backup copy is generated and
stored on site, e.g. on a floppy disk.
By default; all files necessary to perform the backup and restore procedure are
stored in subdirectory C:/Siemens/LMTxxx/BkBts/BTSplusyy on the LMT hard disk
(where yy can be 16, 17 or 18 to indicate BR7.0, BR8.0 or BR9.0 SW version used in
the BTS, respectively).
BTSplus backup files are generated in phase 2 or 3 by performing the following
steps:

start BTS Backup tool (from LMT Evolution , menu View)


Select the command GET (button or file menu)
The objects and attributes of the BTSE are stored in up to 8 TXT files (e.g.
GETBPORP) describing the current configuration. For the restoring these files are
converted into script files (e.g. script1p.lmt) generated.
These script files should be backed up on CD and left in the BTSE so that you can
use them in case of a COBA failure.

46

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Fig. 14 Start BKBTS tool

Fig. 15 Folder for backup files

MN1784EU12MN_0001
2002 Siemens AG

47

Siemens

48

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

11 BTSE restart verification

MN1784EU12MN_0001
2002 Siemens AG

49

Siemens

BTSE commissioning

Power off and on the BTSE to ensure that the BTSE recovers without errors in case
of a total loss of power.

50

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

CB

FP

A
C
O
M

A
C
O
M

A
C
O
M

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

R
X
M
U
C

P T P T P T P T P T P T P T
A P A P A P A P A P A P A P
U
U
U
U
U
U
U

D
C
P
A

D
C
T
P
U

D
C
P
A

B
B
S
I
G

B
B
S
I
G

B
B
S
I
G

D
C
T
P
U

B
B
S
I
G

D
C
P
A

B
B
S
I
G

B
B
S
I
G

D
C
T
P
U

D
C
P
A

M
C
L
K

D
C
T
P
U

D
C
T
P
U

D
C
P
A

C
C
T
R
L

L
I

D
C
P
A

D
C
T
P
U

A
L
C
O
GPSU

FANS
AIR FILTER

Fig. 16 Restart verification

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.

51

Siemens

52

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

12 Functional structure
Cell 0
Abis
LI 0
DUKIT
fx (2:1)

PA 0

DUKIT
0

TPU 0

MSG 0

TPU 1

BBSIG 0
BUS 1

PA 1

RXAMCO
1

BUS 2

DCTPU
0

MCUX 0

DCTPU
1

ALCO 0

DCPA
0

ALCO 0

RXAMCO
1

LMT
Site Inputs
Site Outputs

DCPA
1
FAN 0
-48 V

GPSU 0

Backup
Battery

DC
Breaker

AC/DC 0

PDB

230 V AC

...Diversity

Fig. 17 Functional blocks of a 2 carrier BTSE (BS20) with DUKIT (configured for 1 cell with 2 carriers)

MN1784EU12MN_0001
2002 Siemens AG

53

BTSE commissioning

Siemens

Link
Equipment

Abis

Cell 0

LI 0

DUKIT
fx (2:1)

0
PA 0

DUKIT 0

TPU 0

MCLK 0

TPU 1

BBSIG 1

0
RXAMCO
1
0

DCTPU 0

BUS 1

PA 1

BUS 2

MCLK 0

0
RXAMCO
1

CCTRL 0

DCTPU 1

LMT
Site Inputs

DCPA 1

ALCO 0

Site Outputs

DCPA 1
AC/DC 0

FAN 0
DC
-48 V Breaker
GPSU 0

Backup
Battery

HOST
EXCHANGE

HOSTER

PDB

230 V AC

AC/DC 1

...Diversity

Fig. 18 Functional blocks of a 2 carrier BTSE (BS21E) with DUKIT (configured for 1 cell with 2 carriers)

54

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Abis

LI

PA

TPU

DUCOMT

BUS 1

BUS 2

BBSIG

CCLK

RXAMCO

CCTRL
RXAMCO

LMT

ALCO

FCB 0

...Diversity

230V AC

FP

ACMDC

Fig. 19 Functional blocks of a 2 carrier BTSE (BS22) with DUCOMT (configured for 1 cell with 2 carriers)

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

55

BTSE commissioning

Siemens

Abis
(OVPT, NTPM or Wave)

LI

PA

TPU

BBSIG
BUS 2

HYCOM

BUS 1

RXAMOD

CCLK

RXMUCO

CCTRL
LMT

RXAMOD

Site Inputs

RXMUCO
ALCO
FAN 2

...Diversity

FAN 1

DCPA

DCTPU

GPSU

Site Outputs

FP

-48 V DC

FAN 0

Fig. 20 Functional blocks of a 6 carrier BTSE with HYCOM (configured for 1 cell with 4 carriers)

56

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Abis

LI

PA

TPU

BBSIG

BUS 2

DLCOM

BUS 1

CCLK
RXAMCO

CCTRL
LMT
Site

RXAMCO

Input

...Diversity

ALCO

Site
Output

FAN 2
DCPA

DCTPU

-48 V DC

FAN 1

GPSU

FP

FAN 0

Fig. 21 Functional blocks of a 6 carrier BTSE with DUCOM (configured for 1 cell with 4 carriers)

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN1784EU12MN_0001
2002 Siemens AG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

57

BTSE commissioning

Siemens

Abis

PA

LI

TPU

FICOM

BBSIG

RXAMCO

BUS 2

RXFIL

RXFIL

CCLK

BUS 1

RXMUCO

RXAMCO
CCTRL
LMT

RXMUCO

Site Inputs

ALCO
FAN 2
...Diversity

DCPA

Site Outputs

DCTPU
-48 V DC

FAN 1

GPSU

FP

FAN 0

Fig. 22 Functional blocks of a 6 carrier BTSE with FICOM (configured for 1 cell with 6 carriers)

58

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

13 Exercises

MN1784EU12MN_0001
2002 Siemens AG

59

Siemens

60

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Exercise 1
Commission a BTSE in the Training Center. Remember, in the Training Center you
will find an already running system. Therefore, before you follow chapters 1, 2 and 3
of this register, you have to do some previous work and to add some additional steps
in order to bring the system down.
Previous work to be done:

Write down the name of the software load header file and the software load header
itself for the BTSE. Take a look to the subdirectory containing the BTSE
software on your LMT hard disk. Compare it with the information in the BSC
database.

With which command can you display the currently running software on the BTSE?
Find out the configuration (star, loop or multidrop chain) of the BTSE.
Find out the TEI and SalesUniqueName of the BTSE.
Find out which timeslot is used for LAPD signaling.
Find out whether a 64 kbit/s or a 16 kbit/s timeslot is used for LAPD signaling.
Find out whether or not CRC is used.
Find out whether or not environmental alarms have to be equipped.
Usually find out means: ask your boss or your colleagues. Since we have a running
system in the Training Center you can also interrogate the system itself. Therefore
use the following commands from LMT:
LMT tree:

MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE

Command:

GET BTSE

Name:

NAME=BTSE:0

Attributes:

REQATTL= SWLDINT, SWLDSAF, SWLDST;

Submit
Command line:
GET BTSE SWL: NAME=BTSE:0, REQATTL= SWLDINT, SWLDSAF,
SWLDST;

MN1784EU12MN_0001
2002 Siemens AG

61

BTSE commissioning

Siemens

LMT tree:

MANAGED-ELEMENT --> BSS.FUNCTIONAL --> BTSM

Command:

GET BTSM

Name:

NAME=BTSM:0

Attributes:

REQATTL= ABISCH, TEI;

Submit
Command line:
GET BTSM: NAME=BTSM:0, REQATTL= ABISCH, TEI;
LMT tree:

MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE --> RACK -->


LI

Command:

GET LI

Name:

NAME=RACK:0/LI:0

Attributes:

REQATTL= BERT, LCONF, ALRMT1/2/3, ALRMCOUNTER;

Submit
Command line:
GET LI: NAME=RACK:0/LI:0, REQATTL= REQATTL= BERT, LCONF, ALRMT1/2/3,
ALRMCOUNTER;

62

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Exercise 2
Additional steps in order to bring the system down
I) Lock BTSM and disconnect (by command) BTSE from BSC
From LMT, enter the following commands:
LMT tree:

MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTSM

Command:

LOCK BTSM

Name:

NAME=BTSM:0

Attributes:

none

Submit
Command line:
LOCK BTSM: NAME=BTSM:0;

LMT tree:

MANAGED-ELEMENT --> BSS-FUNCTIONAL --> BTSM

Command:

DISCBSC

Name:

NAME=BTSM:0;

Attributes:

none

Submit
Command line:
DISCBSC BTSM: NAME=BTSM:0;
BTSE switches from phase 3 to phase 2. A new Logon is necessary.

MN1784EU12MN_0001
2002 Siemens AG

63

Siemens

64

BTSE commissioning

MN1784EU12MN_0001
2002 Siemens AG

BTSE commissioning

Siemens

Exercise 3
I) Format CCTRL Flash EPROM
From LMT, perform the following steps:
LMT tree:

MANAGED-ELEMENT --> BSS-EQUIPMENT --> BTSE

Command:

FORMAT BTSE FLASH

Name:

NAME=BTSE:0;

Attributes:

none

Submit
Command line:
FORMAT BTSE FLASH: NAME=BTSE:0;
This procedure requires about 1-2 minutes.
The BTSE switches from phase 2 to phase 1. A new Logon is necessary.
II) Power off the BTSE
Switch off all fuses.
Follow now chapters 1, 2 and 3 of this register to commission the BTSE.

MN1784EU12MN_0001
2002 Siemens AG

65