Академический Документы
Профессиональный Документы
Культура Документы
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted in
any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity, or
performance of the mentioned hardware or software products are given “as is” and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS
DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,
DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT
NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA, THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE
INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of
Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners,
and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2008. All rights reserved.
Contents
Contents 3
List of tables 5
List of figures 6
Summary of changes 7
List of tables
List of figures
Summary of changes
New counters 005034 and 005035 have been added and counters 005006
and 005007 have been updated.
Editorial changes.
Measurement description
Measurement counters
Related topics
Instructions
.
Activating and Testing BSS7064: Handover Support for Coverage
Enhancements
.
Activating and Testing BSS20082: Single Antenna Interference
Cancellation
Reference
Descriptions
. Intelligent Underlay-Overlay
. Support for Enhanced Measurement Report
Updated: When a command is sent causing the new RF power level to become lower than the level
currently used by the MS.
Logical type: Sum Trigger type: Event Sampling interval:
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S1 Definition updated in release: S2
Updated: During calls the RF power level of the MS is sampled at regular 20 second intervals. The
average MS power level used in the cell is calculated on the basis of these samples; 0..19;
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S1 Definition updated in release: S13
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S1 Definition updated in release:
RF power level value mapping (Pmax is the maximum transmission power of the BTS):
0 -> Pmax - 0 dBm
1 -> Pmax - 2 dBm
2 -> Pmax - 4 dBm
...
15 -> Pmax - 30 dBm.
If Pmax is 43 dBm, then the value 0 means 43 dBm and the value 15 means 13 dBm.
The average TRX specific downlink RF power level used in the cell can be calculated by dividing this
counter with the denominator counter 005007 POWER DENOMINATOR 2.
Updated: The RF power level value is sampled every 20 seconds during a call.
Logical type: Sum Trigger type: Sample Sampling interval: 20 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S1 Definition updated in release: S13
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S1 Definition updated in release: S13
Updated: When a command is sent causing the new RF power level to exceed the level on the
channel currently used by the TRX.
Logical type: Sum Trigger type: Event Sampling interval:
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S2 Definition updated in release:
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S2 Definition updated in release: S13
Updated:
Logical type: Sum Trigger type: Sample Sampling interval: 20 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S2 Definition updated in release:
Counter ID: 005014 Network element name: AVE UPLINK SIGNAL STRENGTH
Version: 2.1 NetAct name: AVE_UL_SIG_STR
Description: Strength of the average uplink signal measured in the cell.
NOTE! In case of BB hopping the value is not TRX-specific, but related to one hopping group.
Logical type: Sum Trigger type: Sample Sampling interval: 20 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S2 Definition updated in release: S13
Counter ID: 005016 Network element name: AVE DOWNLINK SIGNAL QUALITY
Version: 2.1 NetAct name: AVE_DL_SIG_QUAL
Description: Average quality of the downlink signal measured in the cell.
Updated: During calls the quality of the downlink signal received from the MSs measurements is
sampled at regular 20 second intervals. The average quality of the downlink signal measured in the
cell is calculated on the basis of these samples.
Quality of the received signal. The value is the percentage value x 100. For example, 14 equals
0.14% (BER); GSM 05.08 (8.2).
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S2 Definition updated in release: S13
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S2 Definition updated in release:
Counter ID: 005018 Network element name: AVE UPLINK SIGNAL QUALITY
Version: 2.1 NetAct name: AVE_UL_SIG_QUAL
Description: Average quality of the uplink signal measured in the cell.
Quality of the received signal. The value is the percentage value x 100. For example, 14 equals
0.14% (BER); GSM 05.08 (8.2).
Rxqual_0 = less than 0.2 %
Rxqual_1 = 0.2 % to 0.4 %
Rxqual_2 = 0.4 % to 0.8 %
Rxqual_3 = 0.8 % to 1.6 %
Rxqual_4 = 1.6 % to 3.2 %
Rxqual_5 = 3.2 % to 6.4 %
Rxqual_6 = 6.4 % to 12.8 %
Rxqual_7 = greater than 12.8 %
NOTE! In case of BB hopping the value is not TRX-specific, but related to one hopping group.
Logical type: Sum Trigger type: Sample Sampling interval: 20 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S2 Definition updated in release:
Updated: During calls the timing advance used is sampled at regular 20 second intervals. The
distance between the MS and the BS within the cell is calculated on the basis of these samples. The
value of the timing advance varies from 0 to 63. One step equals a distance of about 550 metres.
Logical type: Sum Trigger type: Sample Sampling interval: 20 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S3 Definition updated in release: S13
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S3 Definition updated in release:
The value varies from 0 to 63. One step equals a distance of about 550 metres.
Logical type: Max Trigger type: Event Sampling interval:
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
3GPP Measurement name (Clause header):
3GPP Measurement type:
Exceptions to related standard:
Used from release: S3 Definition updated in release:
Description: The sum of sampled TCH interference band values. The BTS reports the interference for
each idle TCH as a band number (0-4, where 0 means the lowest). The average idle TCH interference
level (0-4) can be counted from the ratio between counters 005027 and 005028.
Operability class:
Related to feature: Related to standard:
Counter ID: 005029 Network element name: AVE SUM OF IDLE TCHS PER TRX
Version: 2.2 NetAct name: AVE_SUM_IDLE_TCH_PER_TRX
Description: Sum of the idle TCH samples. The average idle TCH interference level (0-4) can be
counted from the ratio between counters 005029 and 005030.
Note that if the channel type is dual (TCHD) then one time slot gives 3 TCHs in this counter (one FR
TCH and 2 HR TCHs).
Logical type: Sum Trigger type: Sample Sampling interval: 20 s
Unit: Integer number Range: 0-24 Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
Updated:
Logical type: Sum Trigger type: Sample Sampling interval: 20 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
This counter contains MS power control messages where the new commanded RF power level is
higher than the RF power level the MS is currently using while the connection type is 14.4 kbit/s data.
Updated:
Logical type: Sum Trigger type: Event Sampling interval:
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard:
This counter contains BS power control messages where the new commanded RF power level is
higher than the RF power level the TRX is currently using while the connection type is 14.4 kbit/s
data.
Updated:
RF power level value mapping (Pmax is the maximum transmission power of the BTS):
0 -> Pmax - 0 dBm
1 -> Pmax - 2 dBm
2 -> Pmax - 4 dBm
...
15 -> Pmax - 30 dBm.
If Pmax is 43 dBm, then the value 0 means 43 dBm and the value 15 means 13 dBm.
The average TRX specific downlink RF power level used in the cell can be calculated by dividing this
counter with the denominator counter 005035 AVERAGE SAIC BS POWER DENOMINATOR.
Updated: The RF power level value is sampled every 20 seconds during a call.
Logical type: Sum Trigger type: Sample Sampling interval: 20 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Updated: Increased by one every 20 seconds when counter 005034 AVERAGE SAIC BS POWER is
updated.
Logical type: Sum Trigger type: Sample Sampling interval: 20 s
Unit: Integer number Range: Example values:
Dependencies with other counters:
Operability class:
Related to feature: Related to standard: