Module Functions:
User can select from below eight functions, by using the key buttons onboard.
User can select and save the set parameters. The set time is 1 second at
minimum, and precision is better than 0.1 second. The eight functions are as
follows:
1)C lose upon the set time: after power one, the delay time T1 reaches, and
the relay closes. T1 is adjustable between 0 second to 270 hours. When we
feed C H1 a high level pulse signal, the cycle repeats itself (the high level time
lasts longer or equal to 20ms. Same applies to below).
2)Disconnect upon the set time: when the relay closes, the delay time T1
reaches, and the relay opens. T1 is adjustable between 0 second to 270 hours.
When we feed C H1 a high level pulse signal, the cycle repeats itself.
3)C ycle Mode 1: after power on, the relay does not close at first. When T1
reaches, the relay closes. When T2 reaches, the relay opens. And the cycle
goes on. T1 and T2 adjustable between 0 second to 270 hours. When we feed
C H1 a high level pulse signal, the cycle repeats itself.
4)C ycle Mode 2: after power on, the relay immediately closes. When T1
reaches, relay opens; when T2 reaches, the relay closes again, and the cycle
goes on. When we feed C H1 a high level pulse signal, the cycle repeats itself.
5)Self-lock relay mode: we feed C H1 a high level pulse signal, relay closes.
When we again feed a high level pulse signal, the relay opens.
6)Trigger relay mode: we feed C H1 a high level signal, relay closes. When the
high level finishes, the relay opens.
7)Limited cycle mode 1: on basis of function 3, we increase the cycles. Under
this mode, T1 and T2 are adjustable between 0 second to 9999 second, the
cycle is selectable between 1 to 9999 times.
8)Limited cycle mode 2: on basis of function 4, we increase the cycles. Under
this mode, T1 and T2 are adjustable between 0 second to 9999 second, the
cycle is selectable between 1 to 9999 times.
C onnections:
Module control side: there are 3-wire interface, all interfaces are terminal
1, DC +:12V positive
2, DC -: power in negative
3, C H1: Input Detection Interface
Relay outputs: a 3-wire interface, all interfaces are terminal
1, NO: normal open (before relay closes, this pin is not connected. After relay
closes, the pin short-connects with C OM)
2, C OM: Relay C ommon Interface
3, NC : Normal closed (before relay closes, this pin short-connect with C OM.
After relay closes, the pin is not connected )
Specification:
Size:66x40x1.5mm(approx)
PHOTO GALLERY
Add to Cart
Options :
For more efficiancy and to simplify your choice of the requested products, we automatically offer accessoiries,
complementary or matching products. (batteries, cables, accus, etc...)
E lec tronic analys er elec tric module 1 2 vdc from 0
to 9 0 ...
Ref. A E M I