Вы находитесь на странице: 1из 3

850MHz Split Band Selective Repeater

RD-8132
Features

Two sub band-selective modules with independently adjustable bandwidth


to cope with A"A+A or B+B rejecting the competitor band.
Compatible with all modulation schemes (GSM/EDGE/GPRS/CDMA/1xRTT/
EVDO/WCDMA/HSDPA).
Integrated wireless modem for remote configuration, monitor and control.
Automatic control to avoid self-oscillation caused by low isolation between
donor (DT) and mobile (MT) antennas.
Internal backup battery keeps the alarm unit running for up to three hours
after power failure.
Optional OMC is available for remote operation and maintenance of a
group of repeaters.
Designed for all weather outdoor installation waterproof, damp-proof
and omni-sealed (IP65).

Product Description
The RD-8132 dual split band-selective repeater is designed to operate in 850MHz. Band-specific linear amplifier and
filtering effectively amplifies the desired BTS carriers and provides superior out-of-band rejection. The unit incorporates
two filter modules, the first one with adjustable bandwidth 2-15MHz and the second one with adjustable bandwidth
1-6MHz. This way you can amplify B+B suppressing the A and A band or vice versa. Remote configuration and
surveillance is possible through Combas remote control and monitoring system via PC or wireless modem to the
OMT/OMC. Internal Li-ion backup battery ensures alarm signals are sent out during power failure, an optional external
backup battery ensures operation in conditions with insufficient power supply or unstable supply voltages. The RD-8132
comes in a sealed, cast aluminum enclosure, suitable for operation in all weather conditions.

Functional Block Diagram

ALC
DLBand Selective
Module

M-ATT
LNA1

PA1

ALC

Downlink

DLBand Selective
Module

Donor
Ant

Mobile
Ant

ALC

DT

MT

DLBand Selective
Module

Mobile

M-ATT
PA2

LNA2

ALC
DLBand Selective
Module

Uplink

RPS
Computer with
Data card
Alarm
Indicator
Wireless
Modem

Main Control Unit

Power
Supply

Li-ion
BATT

Modem

External
Power

OMC
RPS

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

RD-8132

Issue:24Feb06
Uncontrolled: 2-6-0 / B6
1/3

850MHz Split Band Selective Repeater


RD-8132
Technical Specifications

Model

10W

Electrical
Frequency Range, Uplink

MHz

824 - 849

Frequency Range, Downlink

MHz

869 - 894

MHz

2 15 and 1-6

dB

60 90

Number of filter modules

Operating Bandwidth (BW)


Gain Adjustment Range (1dB step)
Total Output Power PEP Downlink

dBm

40

Total Output Power PEP Uplink

dBm

33

Pass Band Ripple @ FBW, p-p

dB

System Noise Figure at Max. System Gain

dB

sec

System Group Delay

6 (typical 4)

at Offset 400KHz

dB

at Offset 600KHz

dB

>45

at Offset 1MHz

dB

>60

Spurious

dBm

-36

Intermodulation

dBm

-13

Absolute Maximum RF Input Power

dBm

Band width selectivity

>30

+10
1.5

Input VSWR
Impedance

50

mm

600 x 450 x 195

Power, Mechanical & Environmental


Dimensions, H x W x D
Weight (approx.)

kg

37

Power Consumption (approx.)

200

Power Supply

VAC

Power Up Waiting Time (approx.)

sec

MCU Battery Backup Time (approx.)

hr

90-135/176 264 / 47 - 63Hz


60
3

Enclosure Color

Grey

Enclosure Material

Aluminum

Enclosure Cooling

Convection

Connectors

DIN/N-Female

Operating Temperature

Operating Humidity

-40 to +55
95

Environmental Class
MTBF

IP65
> 50,000

hr

Note: Typical specification at room temperature

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

RD-8132

Issue:24Feb06
Uncontrolled: 2-6-0 / B6
2/3

850 MHz Dual Split Band Selective Repeater


RD-8132
Operation and Maintenance
Using a direct serial connection to a PC, installation and commissioning of the RD-8132 is accomplished by the OMT. Using
the integrated wireless modem (data or SMS), the equipment parameters can be monitored and controlled remotely.
Controlled equipment parameters include: Channel No. Range, ATT, Soft ON/OFF, Oscillation Control ON/OFF, Over-Temp
Threshold, DL Output Power Threshold, DL Input Power Threshold and Alarm Report Enable.
Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault, Chassis Lock,
Self-Oscillation, DL Input Power Low, DL Output Power Low, Over Temp, VSWR), UL/DL Output Power and DL Input Power
The RD-8132 has been developed to take advantage of advanced network operation, where the OMC (optional) provides
an effective solution for central monitoring of a group of Comba products.

600

Outline Drawing

9122

450

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

RD-8132

Issue:24Feb06
Uncontrolled: 2-6-0 / B6