Dual Frequency Combiner

Trunk Amplifier

User Manual
GZF-DW-VI (40M00JC02A3Y)

FiberHome reserves the right to make changes without further notice to any products
herein to improve reliability, function or design. FiberHome dose not assume any liability arising
out of the application or use any product or circuit described herein.

No part of this documentation may be excerpted, reproduced, translated,


annotated or duplicated, in any form or by any means without the prior written
permission of FiberHome Corporation.
All rights reserved.
Copyright 2012 FiberHome Corporation.

Instruction for your safety


Please be sure to pay attention to all cautions and
warnings before using the system.
Incorrect usage could lead to an electrical shock,
damage to the system or a fire hazard.
Warning

Do not modify, disassemble or remove the cover. These action could cause
electrical shock. We shall never be responsible for any problems caused by your
reconstruction or modification.
Do not touch the internal components. They may have high voltage or high
temperature. You may get electrical shock or burnt.
When the system is operating, keep your hands and face away from it. Otherwise,
you may get injured by an accident.
Caution

Please read catalogue and instruction manual carefully before use.


Use the products within the specified input voltage, temperature and humidity.
Use of products in non-specified condition may damage the product.
Connect the frame ground terminal to the ground terminal of the device for
safety. Use of the products without ground connection may cause an electrical shock.
Do not use the product in the environment with strong electromagnetic field, gas
and conductive substances.

Preface
GZF-DW-VI Trunk Amplifier is widely used for constructing a hybrid DCS/
WCDMA mobile communications network. It receives and amplifies forward and
reverse Radio Frequency (RF) signal to extend the coverage of base station.
This Element Management System Manual covers the system frame, technical
specification, operation and maintenance of software of the Trunk Amplifier.

User Manual
INDEX

INDEX
1. Genera
1.1 System Frame.............................................1
1.2 Product Features.........................................1
1.3 Hardware and Software Configuration
Requirement......................................................2
1.4 Technical Specification................................ 3
1.4.1 Specification of GZF-DW-VI..................... 3
1.4.2 Other Specification................................... 4
1.5 Interfaces.....................................................4

2. Installation
2.1 Installation Flow...........................................5
2.2 Project preparations.................................... 6
2.2.1 Users cooperation................................... 6
2.2.2 On-site survey..........................................6
2.2.3 Installation tools........................................6
2.3 Installation Conditions................................ 6
2.3.1 Basic installation conditions..................... 6
2.3.2 Recommended environment requirements.7
2.4 Equipment Check........................................7
2.4.1 Counting the goods.................................. 7
2.4.2 Unpacking inspection............................... 7
2.5 Installation of the Main Chassis of the
Repeater............................................................8
2.5.1 Grey case mounting................................. 8

3. Monitoring Software
3.1 Software Operation Flow............................. 9

3.2 Configuration Requirement......................... 9


3.2.1 Computer Requirement............................ 9
3.2.2 Other Monitoring Instruments
Requirement....................................................10
3.3 Initial Operation......................................... 11
3.3.2 Initial Monitor Setting.............................. 12
3.3.1 Configure the Monitor Software.............. 12
3.4 Monitor Interface Illustration...................... 13
3.4.1Repeater Info...........................................13
3.4.2 Principle Settings....................................14
3.4.3 Alarm Report..........................................15
3.4.4 Realtime Data.........................................16
3.4.5 Extend Query.........................................17
3.4.6 Device TelNum And Query/Set Number
Settings...........................................................18
3.5 SMS Monitor..............................................19
3.5.1 Basic Setting .........................................19
3.5.2 SMS Alarm Report..................................21

4. Maintenance
4. Maintenance................................................22

5. Packing List
5. Packing List ................................................23
History.............................................................23

User Manual
1. General
1. General
1.1 System Frame
The following figure shows the system frame of GZF-DW-VI Dual
Frequency Combiner Trunk Amplifier.

D
L
X

LNA
Door
Sensor

PA

DCS
Rx

DCS
Rx

Tx

Tx

Monitor

D
L
X

Cable
Access

WCDMA
Tx
Rx

WCDMA
Rx
Tx

PA

LNA
MODEM
RF signal flow

Power Supply
Monitoring signal flow

Antenna

GZF-DW-VI(40M00JC02A3Y))

1.2 Product Features


1. Excellent RF performance: FiberHome provides wireless
repeaters with state-of-the-art performance such as minimized noise
figure, time delay and IMD, excellent link balance and out-of-band
suppression.
2. Modular design: Modular design is easier for operators to make
upgrade and for maintenance.
3. Monitor and control (M&C): The interior M&C module is the core
to control the whole repeater and implements four functions: detection,
control, communication, and alarming. The standby battery on the M&C
board supports the normal running of the system.
4.

Perfect query, statistic and report: It can support query, statistic

and report for the history data including log, repeater data and query data
etc.

Page

2/ 3

5.

Reliability: Industrial-level components are used, which can

sustain a temperature range of -25C ~ +55C (for outdoor repeater only)


so that the product can work reliably in a wide range of environments; the
power supply of the integrated system is designed with high redundancy to
make sure that the power module can work under normal load in 55C and
start normally in -25C; the repeater is provided with multi-level lightning
protection devices to ensure reliable lightning protection for the power
supply, antenna and feeder. The lightning protection device of the power
supply is a combination of a gas discharge tube and a piezo-resistor and
is designed with 2-level protection, so that it can absorb very high lightning
strike energy as well as remove residual voltage satisfactorily.
6.

Input power: Input power of repeater should follow the table

below.
Rpt Type

Optical Fiber Repeater


Cable Access FSR
Master

Wireless Repeater
FSR Slave

Mini Repeater

Forward (dBm)

-80 ~ -50

-75 ~ -45

-15 ~ -5

Reverse (dBm)

-80 ~ -50

-75 ~ -45

-80 ~ -50

Link

Note: Repeater maybe can not reach its rated output power even
though its input power follows the table above, since output power is also
determined by system gain.

1.3 Hardware and Software Configuration


Requirement
1. Computer hardware
CPU primary frequency: 1.8G or above, 256M memory or above,
above 16M graphic memory, 15" display with pixel of 800600;
Options: 16-bit sound card, sound box, laser or jet printer.
2. Computer software
If installing V5.1.0 (Local version), it is suggested to install
Window2000/ XP/Window2003. It is necessary to install DirectX (8.0 or
above) for Window98/ME.

Element
Management
User
Manual System Manual
1. General

There is no special requirement for configuring communication


server.

1.4 Technical Specification


1.4.1 Specification of GZF-DW-VI
Item

Specification
Uplink

Downlink

Frequency range

1710-1785MHz

1805-1880MHz

Maximum Output Power

-5dBm2dB

40 dBm2dB

DCS

Gain

453dB

Gain adjustment range

20dB

Gain adjustment step

1dB

Ripple in band

4dB

UL.Noise Figure

5dB

System Delay

1.5us

Spurious
Emission

9KHz~1GHz

-36 dBm/100KHz

1GHz~12.75GHz

-30 dBm/1MHz

VSWR

1.5

WCDMA
Frequency range

1920-1980MHz

2110-2170MHz

Maximum Output Power

-15dBm2dB

40dBm2dB

Gain

453dB

Gain adjustment range

20dB

Gain adjustment step

1dB

Ripple in band

2dB/3.84MHz

UL.Noise Figure

5dB

System Delay

5us

Spurious Emission
VSWR

9KHz~1GHz

-36 dBm/100KHz

1GHz~12.75GHz

-30 dBm/1MHz
1.5

Page

4/ 5

1.4.2 Other Specification


MECHANICAL SPECIFICATION
Dimensions Approx.

630510330mm

Weight Approx.

50kg

Ingress Protection Class

IP65

ENVIRONMENT SPECIFICATION
Storage

-40

Operating Temperature

+5

Humidity

+85

+40(indoor)
95%

OTHER SPECIFICATION
System Impedance

50

Cooling

convection

RF Connector

N-type

Power Supply

AC 176 264V, 45 55Hz

Power Consumption

270W10%

1.5 Interfaces
Antenna interface: N-type connector
Module control Interface: RS485
Laptop interface: RS232

User Manual
2. Installation
2.1 Installation Flow
The general workflow of the Repeater is shown in Fig. 2-1.

Start
Project Preparation

Unpacking&goods checking

Antenna&feeder installtion

Repeater installtion

Grounding

AC power connection
End
Fig. 2-1 general workflow of the repeater installation

To ensure your safety during the installation, make sure to wear


safety belt and safety hat during installation work.
It is forbidden at anytime to work in rainstorms.

Page

6/ 7

2.2 Project preparations


2.2.1 Users cooperation
Hongxins technicians will take charge of the equipment installation
and the users technicians should provide help if necessary. To ensure the
normal running and maintenance of the equipment, the users technicians
should proactively work together with Hongxins engineers and technicians
and get familiar with the installation, structure, cabling, debugging
procedure, etc.

2.2.2 On-site survey


Before installation, the installation technicians should consult
with the project manager of the user and learn whether the installation
site is ready for equipment installation. Specifically, they should survey
such items as the installation site, iron tower or high pole, surrounding
environment (temperature and humidity) and power supply. Where
conditions permit, they should make an on-site survey together with the
relevant persons of the user.

2.2.3 Installation tools


Installation tools include: electric percussion drill, iron hammer,
pulley, rope, safety belt, safety hat, ladder, screwdriver, hacksaw, knife,
pliers, spanner, compass, tape, tweezers, electric iron, etc.

2.3 Installation Conditions


2.3.1 Basic installation conditions
The repeater is designed to work outdoor under the temperature
-25~55 (5~40 for indoor repeater) and relative humidity up to
95%, so it can work in the indoor/outdoor natural environments in most
areas. The following basic conditions should be ready before installation:
1. 220V AC power is available.
2. A grounding bar is available nearby.
3. There are appropriate buildings, iron towers or high poles to
mount the donor antenna and service antenna.

User Manual
2. Installation
2.3.2 Recommended environment requirements
1. The installation height should be such as to facilitate RF cabling,
heat radiation, safety protection and maintenance.
2. Independent and stable power should be provided, which mustnt
be shared with other large-power communication equipment and electric
appliances.
3. The installation building, iron tower or high pole should be
provided with lightning protection facilities and should be strong and stable
enough.
4. The antenna backstay or roof should be provided with a pole
to help mount the antenna. The diameter of the pole may be 50mm ~
105mm, depending on the antenna to be mounted. A ladder should also
be available to help mount the antenna. All metal parts should be properly
grounded and provided with lightning protection facilities.

2.4 Equipment Check


2.4.1 Counting the goods
Check whether the packing box is intact in appearance. If any goods
are wrong or missing or if the outer package is damaged seriously, stop
unpacking immediately and find out the cause, and report to the relevant
department.

2.4.2 Unpacking inspection


Open the packing box if it is intact. Handle with care to avoid
damaging anything.
After the packing box is opened, check whether the goods inside
match the packing list and whether the packing list matches the inspection
list in the Unpacking Inspection Report. If any goods are wrong or missing
or if the outer package is damaged seriously, find out the cause, and
report to the relevant department.
After unpacking inspection, fill out the Unpacking Inspection
Report. Both parties shall sign the Report, and then the goods shall

Page

8/ 9

be handed over to the user. Each party shall hold one copy of the
Unpacking Inspection Report, and the project supervisor should feed
back the Inspection Conclusion within seven days to the vendor for
documentation.

2.5 Installation of the Main Chassis of the Repeater


The Repeater is attached with such installation fittings as installation
board and fixing pieces. The chassis of the Repeater can be mounted
either on the wall or on a high pole
The bottom of the equipment is usually about 1.2 m above the
ground.
Your repeater should be one of the following cases.

Fig. 2-2 pole mounting

Fig. 2-3 wall mounting

User Manual
3. Monitoring Software
3.1 Software Operation Flow
The general workflow of the Monitor Software is shown in Fig. 3-1.
Start

Hardware and Software


Environment Check

Monitor Software
Installation

Equipment Connection

Commission Test

End

Fig. 3-1 The general workflow of the Repeater


To ensure safety during the installation, make sure to wear safety
belt for overhead operations and wear safety hats for on-the-ground
operations, and take care never to work in rainstorms.

3.2 Configuration Requirement


3.2.1 Computer Requirement
3.2.1.1 Hardware
CPU primary frequency1.8G or above, 256M memory or above,

Page

1 0 / 11

above 16M graphic memory, 15" display with pixel of 800600;


Options: 16-bit sound card, sound box, laser or jet printer.
3.2.1.2 Software
It is suggested to install Window2000/ XP/Window2003. It is
necessary to install DirectX (8.0 or above) for Window98/ME.

3.2.2 Other Monitoring Instruments Requirement


3.2.2.1 Local Monitor Method
The instruments we need in this case include: a RS232 cable, a PC
or laptop
Here is a photo of a RS232 cable:
1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

Port 1

Port 2

The pin 2 and pin 3 of the RS232 cable are crossing connected,
and two pins 5 of the two tie-ins are connected directly. Pins left are not
connected.
The following figure explains how to use a RS232 cable to do
monitoring work.

RS232 Cable

Monitor Center

Repeater

User Manual
3. Monitoring Software
3.2.2.2 Remote Monitoring Method
In this case, what we need should include:
1. One PC or laptop;
2. One 9-stitch straight-through cable ;
3. One set of modem which supports DCS1800 communication
method, including its own power supply unit, e.g. HXMO900-3;
4. One small antenna which also supports DCS1800 communication
method
5. One SIM card which support data transfer to insert into the
Modem module
The following figure explains how to use a modem module to finish
the remote monitoring work.

Monitor Center

Modem

Repeater

Note: before testing, please insert a SIM card into the equipment.
And make sure both these two cards mentioned above have enough
money to sent SMS or other remote services.

3.3 Initial Operation


Note: Please excuse us for not giving any further notice about any
changes of operation. FIBERHOME privileges to the final explanation of
LMS.
Our LMS just has one set of software. We take local version
software as an example to explain how to operate the software. It is
applicable in the windows2000, and windows XP operation system.

Page

1 2 / 13

3.3.1 Configure the Monitor Software


To open the software, click the icon LMSEP

3.3.2 Initial Monitor Setting


Turn to WKE(W)5.289.287R1.0.1.dcf

Then you will see the interface below:


For local monitoring, click Open SerialOn-line.andSave
ConfigInfo.
NoteThe Site Number and Device Number must be the
same to the equipments, or else, any query or setting will be failed.
Furthermore, if your monitor center does not have any serial port, there
will be a notification like this:

User Manual
3.Monitoring Software

In this case, please click the button and check your computer.

3.4 Monitor Interface Illustration


All the interface functions are in the operation manual which we
provide. The following illustrations below are some important interfaces
that have strong relevance with the coverage quality in the site opening.
The settings of these interfaces are the manufacture initial setting, and on
the site it may need some change of these setting.

3.4.1Repeater Info

Page

1 4 / 15

Note: Please refer to local engineers suggestion for actual


parameters for above items. Choose the NM Parameter

3.4.2 Principle Settings

Before setting, please click the button Query first, in case of faults.
Then choose the function you need, and click Query. The data must be
set as the picture above.

User Manual
3.Monitoring Software
3.4.3 Alarm Report

Before setting, please click the button Query first, in case of faults.
Under the condition of that all the alarms are enabled, the interface reports
the alarms of the equipment under monitoring.

Page

1 6 / 17

3.4.4 Realtime Data

Choose Query to query each real time data. And from the data,
you can know the equipments working statue is normal or not.

User Manual
3.Monitoring Software
3.4.5 Extend Query

Select the option module status query, and click the blank area
beside, then all the modules of the equipment can be queried. From the
table, the module which failed to be queried may be estimated to be
working improperly. And then it is suggested that sending engineer to
check and handle it.

Page

1 8 / 19

3.4.6 Device TelNum And Query/Set Number Settings

Before Monitor and control, Query/set up a phone number should


be set correctly with RS-232 to make sure that SMS can be used.

User Manual
3.Monitoring Software
3.5 SMS Monitor
3.5.1 Basic Setting

For SMS monitor, after setting the right Device TelNum , the reported
number and the Query/set up a phone number, select Init Data. If it
succeeds, such a window shows.

Click Communication, and then choose SMS.

Page

2 0 / 21

After clicking the button On-line, the basic information of the


Repeater will be displayed.
The following operation is according to 3.4.

User Manual
3.Monitoring Software
3.5.2 SMS Alarm Report

In order to use SMS alarm report, turn to Base and click Reported
to the communication, choose Message and click SET (F4). Then all the
alarm report through SMS.

Page

2 2 / 23

User Manual
4.Maintenance
4. Maintenance
Generally, theres no need to maintain specially after opening.
Though the Monitor & Maintenance Center can query the equipments
statue directly, we still advise an ordinary regular checking:
Check whether the cables, the fixtures, power connection are good
or not. If there is any problem, solve it immediately.
Make sure the lightning protection system and grounding are good
Check the equipments power supply.
Test and record the equipment main specifications regularly(such as
downlink output power, uplink gain, downlink gain, etc)
Test the uplink output Noise Level, and compare its value with the
record. If their difference is too large, find out the solution.
Test the coverage effect of whether the system is expected initially
or not.
Check the monitoring performance
Check all kinds of labels of the equipment are integrated or not.
Notes: If there is any problem with the equipments, solve it in time
and record it, or contact with us.

User Manual
5.Packing List
5. Packing List
SEQ

MODEL

UNIT

QTY

set

GZF-DW-VI

Configuration List

piece

User Manual

piece

Software Disc

piece

RS232 cable

piece

Test Notes

Piece

History
Version

Date

FiberHome/SM/GZF-DW-VI/RA.0

2012/4/2

Remark
For Vietnam DCS1800 &WCDMA2100

Page

30/

Wuhan Hongxin Telecommunication


Technologies Co., LTD.
Tel: 86-27-87691380