TEST CERTIFICATE
Equipment
Manfc.No:
2134/1
Construction :
Ring type
Tipe
3161
Inside dia.:
8"
Length:
9 mtrs
Specification :
Date :
20
16
16.10.2012
Chief Officer:
Chief Engineer:
A.KHARCHENKO
YURIY MEDVEDEV
M/T "TAIBAH"
TEST CERTIFICATE
Equipment
Manfc.No:
FLEX0816
Construction :
Ring type
Form
Material
SUS316L
Specification :
Inside dia.:
8"
Length:
9 mtrs
Date :
16.10.2012
Chief Officer:
Chief Engineer:
A.KHARCHENKO
YURIY MEDVEDEV
M/T "TAIBAH"
TEST CERTIFICATE
Equipment
Manfc.No:
FLEX0816
Construction :
Ring type
Form
Material
SUS316L
Specification :
Inside dia.:
8"
Length:
9 mtrs
Date :
16.10.2012
Chief Officer:
Chief Engineer:
A.KHARCHENKO
YURIY MEDVEDEV
M/T "TAIBAH"
TEST CERTIFICATE
Equipment
Type
SUS316L
Manfc.No:
FLEX0816
Material
SUS316L
Inside diam:
8''
Length:
12 mtrs
Date :
20
16
16.10.2012
Chief Officer:
Chief Engineer:
A.KHARCHENKO
YURIY MEDVEDEV
M/T "TAIBAH"
TEST CERTIFICATE
Equipment
Manfc.No:
FLEX0816
Construction
Ring type
Form
Material
SUS316L
Specification
Inside dia.:
8"
Length:
9 mtrs
Date :
16.10.2012
Chief Officer:
Chief Engineer:
A.KHARCHENKO
YURIY MEDVEDEV
M/T "TAIBAH"
TEST CERTIFICATE
Equipment
: Portable tanks cleaning machine's hose
Type
: Junior Jetstream
Manufacturer
: DASIC
Length
: 25 meters
Item inspected/tested : Electrical conductivity a/p to ISGOTT - 11.3.6.3
40 Ohms. Satisfactory
Result of testing
:
1.7
/m
Ohms/meter
:
This is to certify, that on 16th January 2013 the above equipment
has been tested, as specified above, and found in good working order.
Electrical conductivity of the hose is found corresponding to the safety
value (less than 6 Ohms per meter of length).
Date :
16.01.13
Chief Officer:
El officer
M/T "TAIBAH"
Shamik Saha
Muggu Upendra
TEST CERTIFICATE
Equipment
: Cargo hoses
Item inspected/tested : Electrical conductivity a/p to ISGOTT - 18.2.6.4
Type
ID nr.
xL
/m
U-type Omega type
1
8" x 12m
5.1
0.425
U-type Omega type
2
8" x 9m
4.4
0.4889
U-type Omega type
3
8" x 9m
4.6
0.5111
Willcox Composite
4
8" x 9m
4.5
0.5
This is to certify, that on16th January 2013 the above equipment
has been tested, as specified above, and found in good working order.
Electrical conductivity of the hose is found corresponding to the safety
value (less than 0.75 Ohms per meter of length).
Date
16.01.13
Chief Officer:
El officer
Shamik Saha
Muggu Upendra