L322
EPIC
F611
CI/SfB
(2-)
Ff5
2003
Product Data
PD9
Standards
Lintels do not conform to a defined
standard. Reinforcement conforms
to BS 4449 and tension bars are bent
to BS 4466. Trough lintel blocks
conform to BS 6073: 1981. Quality
is controlled at every stage, with
procedures assessed and certified
to BS EN ISO 9002 standards.
Lintel Range
Surface Texture and Colour
To match Lignacite, Lignacrete or
Architectural Facing Masonry blocks.
Refer to separate Data Sheets on
these products. Dummy perpends
can be incorporated into beam lintels.
Heights
215mm (standard) or 190mm
(metric modular).
Trough lintels may be designed
as a double height layer in order
to accommodate exceptional loads
or spans.
Lengths
Beam lintels
in any length within manufacturing
and performance limits - see table 2.
Trough lintels
440mm or 215mm (standard), or
390mm or 190mm (metric modular).
Widths
75mm to 215mm - see tables overleaf.
Structural Performance
Lintel design:
For use in masonry where no point
loads or openings occur within the
60 load triangle (Fig 2)
Application
The following alternative methods of
assessing the loads and checking the
suitability of lintels are suggested:
Method 1
Assess the total load (W) on
the lintel using the weights of
building Materials in BS 648.
Calculate the maximum Bending
Moment (BM) and Shear Force (SF)
for the different types of load
indicated on fig 1 and 2.
WL
8
SF =
W
2
Total load W
clear span + 180
Method 2
WL
6
SF =
W
2
load
triangle W
60
clear span + 180
L
High Street, Brandon, Suffolk IP27 0AX - Tel: 01842 810678 - Fax: 01842 814602 - E-mail: info@lignacite.co.uk - Website: www.li gnacite.co.uk
Meadgate Works, Nazeing, Waltham Abbey, Essex EN9 2PD - Tel: 01992 464441 - Fax: 01992 445713
33
Product Data
service values
Width
(mm)
Type
safe
Lengths (mm) 1115 1340 1565 1790 2015 2240 2465 2690
Clear Span (mm) 685 910 1135 1360 1585 1810 2035 2260
Resistance
moment
kNm
Shear
Resistance
kN
Maximum
UDL
kN
Width
(mm)
Type
Unit Weights
(kg)
75
Lignacite
1.52
0.92
1.84
75
Lignacite
30
36
42
48
54
60
75
Lignacrete
3.02
1.70
3.40
75
Lignacrete
40
48
56
64
72
80
90
Lignacite
1.52
0.92
1.84
90
Lignacite
36
43
50
58
65
72
90
Lignacrete
3.02
1.70
3.40
90
Lignacrete
48
57
67
77
86
95
100
Lignacite
2.19
1.83
3.66
100
Lignacite
40
48
56
64
72
80
100
Lignacrete
6.04
2.74
5.48
100 Lignacrete
53
64
75
86
96
107
140
Lignacite
3.08
2.75
5.50
140
56
68
79
91
140
Lignacrete
9.08
3.93
7.86
140 Lignacrete
74
89
150
Lignacite
3.27
2.75
5.50
150
59
72
84
150
Lignacrete
9.08
3.93
7.86
150 Lignacrete
79
95
77
93
Lignacite
Lignacite
190
Lignacite
4.16
3.66
7.32
190
190
Lignacrete
12.08
5.30
10.60
190 Lignacrete
Lignacite
200
Lignacite
4.37
3.66
7.32
200
200
Lignacrete
12.08
5.30
10.60
200 Lignacrete
Lignacite
215
Lignacite
4.70
4.14
8.28
215
215
Lignacrete
15.13
6.20
12.40
215 Lignacrete
Lignacite
96
98
R e i n f o r c e d S i n g l e Tr o u g h B l o c k L i n t e l s 2 1 5 m m h i g h
Performance Data - Table 3
Overall
Width
(mm)
Core
Height
Width
(mm)
Reinforcement
Bars*
Links
Maximum
clear span
(mm)
Shear
Resistance
(kN)
100
165
40
1x
T12
Single leg
R6 at
100mm c/s
2260
15
4.5
4.5
140
165
70
2x
T12
Two legs
R6 at
100mm c/s
4060
28
7.2
7.2
5.9
4.6
3.8
3.3
150
165
70
2x
T12
Two legs
R6 at
100mm c/s
4060
28
7.2
7.2
5.9
4.6
3.8
3.3
190
165
110
3x
T12
Two legs
R6 at
100mm c/s
4510
35
11.4
11.4
9.2
7.2
5.9
5.1
4.3
200
165
110
3x
T12
Two legs
R6 at
100mm c/s
4510
35
11.4
11.4
9.2
7.2
5.9
5.1
4.3
215
165
135
4x
T12
Two legs
R6 at
100mm c/s
4510
39
14.0
14.0
11.4
8.9
7.4
6.4
5.4
34
4. Cover to reinforcement to be
15mm. Bar ends to be bent to
BS 4466. Minimum end bearing
to be 215mm.
5. Concrete for reinforced in-situ
core to be minimum 35N/mm2
with 10mm maximum size
aggregate, thoroughly compacted.
Te l : 0 1 8 4 2 8 1 0 6 7 8 - W e b s i t e : w w w. l i g n a c i t e . c o . u k