Вы находитесь на странице: 1из 130

Siemens AG 2012

System Cubicles, System Lighting


and System Air-Conditioning
Catalog LV 50 2012

SIVACON
Answers for industry.

Siemens AG 2012

Related catalogs

Contents

Low-Voltage Power Distribution and LV 10.1


Electrical Installation Technology
SENTRON Protection, Switching, Measuring
and Monitoring Devices

Air circuit breakers Molded case circuit breakers Miniature


circuit breakers Residual current protective devices
Fuse systems Overvoltage protection devices Switch
disconnectors Switching devices Transformers, bells and
socket outlets Busbar systems Measuring devices and
power management Monitoring devices Software

LV 10.2

E86060-K8250-A101-A2-7600
Low-Voltage Power Distribution and
Electrical Installation Technology
SIVACON Switchboards and
Distribution Systems

Switchboards Busbar trunking systems System cubicles


and cubicle lighting Cubicle air-conditioning
Distribution boards Terminal blocks

E86060-K8260-A101-A2-7600
ALPHA
Distribution systems

LV 51

SIVACON
LV 56
Power Distribution Boards SIVACON S4

PDF only
(E86060-K1851-A101-A1-7600)

ALPHA SIMBOX WP small distribution boards ALPHA 125


UNIVERSAL distribution boards ALPHA 630 UNIVERSAL
distribution boards ALPHA AS 800 UNIVERSAL distribution
boards Assembly kits/Accessories for ALPHA UNIVERSAL
distribution boards ALPHA 8HP molded-plastic distribution
systems

Power distribution boards Standard configurations Cubicles, supporting structure and enclosure Busbar systems
Assembly kits for protection and switching devices Covers,
modular doors, mounting plates and 19" racks Internal separation System air-conditioning Accessories

E86060-K1856-A101-A1-7600
SIVACON 8PS
Busbar Trunking Systems
CD-K, BD01, BD2 up to 1250 A

LV 70

Busbar Trunking Systems, Overview CD-K System


(25 A ... 40 A) BD 01 System (40 A ... 160 A)
BD2 System (160 A ... 1250 A)

E86060-K1870-A101-A6-7600
Products for Automation
and Drives
Interactive Catalog

CA 01

All products of automation, drives and installation technology,


including those in the catalogs listed above.

DVD: E86060-D4001-A510-D2-7600
Industry Mall
Information and Ordering Platform
in the Internet:

All products of automation, drives and installation technology,


including those in the catalogs listed above.

www.siemens.com/industrymall
Catalog PDF
Internet:

All catalogs for low-voltage power distribution and electrical


installation technology can be downloaded as PDF files.

www.siemens.com/lowvoltage/infomaterial

Trademarks
All product designations may be registered trademarks or
product names of Siemens AG or other supplying companies.
Third parties using these trademarks or product names for
their own purposes may infringe upon the rights of the trademark owners.
Further information about low-voltage power distribution and
electrical installation is available on the Internet at:
www.siemens.com/industrymall
Siemens LV 56 2011

Technical Support
Expert advice on technical questions with a
wide range of demand-optimized services
for all our products and systems.

www.siemens.com/lowvoltage/technical-support

Siemens AG 2012

SIVACON
System Cubicles,
System Lighting and
System Air-Conditioning

System Overview

Cubicle Racks

Enclosures

Cubicle Expansions

Preconfigured Cubicles

Special Cubicles

System Lighting

System Air-Conditioning

Superseded:
Catalog LV 50 2009 (German version)
For the latest updates of this catalog,
please visit our Industry Mall:
www.siemens.com/industrymall
The products in this catalog can also be found
in the interactive catalog CA 01.
Order No.:
E86060-D4001-A510-D2-7600
Contact your local Siemens sales office
for further information
Siemens AG 2012

SIVACON 8MR / 8MF

With commercial data valid in Germany


from May 2012

The products and


systems listed in this
catalog are
manufactured/
distributed using a
certified quality
managementsystem
which complies with
EN ISO 9001
(Certificate Register No.
1210016950 TMS). The
certificate is recognized
in all IQNet countries.

SIVACON sicube 8MF

Catalog LV 50 2012

Appendix

Siemens AG 2012

Siemens LV 50 2012

The right one for everyone

Sustainability in focus

Our portfolio includes switchboards, busbar trunking systems, distribution boards,


protection, switching, measuring and
monitoring devices, building management systems, switches and socket outlets. All over the world, the universality,
modularity and intelligence of our components and systems give you innumerable
benefits all the time they are in use. Developed according to the respective international standards, we offer forwardlooking design with innovative functions
and ensure the highest quality standards
world-wide.

As a worldwide leader in the provision of


high-quality, standards-compliant products and systems for low-voltage power
distribution, we contribute to the sustainable and responsible handling of electrical
energy. With our integrated portfolio of
energy saving and distribution through
short circuit protection and overload protection through to energy management,
we support the implementation of environmentally friendly energy concepts on
the basis of wind power, photovoltaics, intelligent buildings and electromobility.

Siemens AG 2012

Universal, safe and intelligent


power distribution
Whether in industrial plants, in infrastructure or in buildings: Each technical plant depends on the reliable supply of
electricity. Even a short outage can have grave consequences. We offer the best technology for the responsible
use of electrical energy and at the same time help to protect people and property and to conserve natural resources.
We are happy to help you with comprehensive support
from the initial information through to operation. Take a
closer look at all the options available from Siemens.

Everything for power distribution

Excellent support

Consistent solutions are required for electric power distribution in buildings. Our
answer is Totally Integrated Power (TIP).
TIP stands for innovative products, systems and software tools which ensure the
safe and reliable distribution of electric
power. They are supplemented by communication-capable circuit breakers and
modules which connect the power distribution system to the building automation
system or industrial automation solutions. These in turn can be linked to a
comprehensive energy management system which contributes to optimizing the
consumption of electricity and hence to
lowering the costs of operation.

As a competent and reliable partner, we


also offer you comprehensive support
from the initial information, through planning, configuring and ordering to commissioning, operation and technical support. We know the needs of your working
environment and your daily business.
Based on this, we give you flexible and
high quality support, which allows you to
concentrate fully on your customers and
their needs.

Siemens LV 50 2012

Siemens AG 2012

Much more
than a catalog.
The Industry Mall.

Selecting
Find your products in the structure tree, in the new "Bread-crumb"
navigation or with the integral search machine with expert functions.
Electronic configurators are also integrated into the Mall. Enter the
various characteristic values and the appropriate product will be displayed with the relevant order numbers. You can save configurations,
load them and reset them to their initial status.

You have a catalog in your hands that will serve


you well for selecting and ordering your products.
But have you heard of the electronic online catalog (the Industry Mall) and all its benefits? Take a
look around it sometime:

Ordering
You can load the products that you have selected in this way into the
shopping basket at a click of the mouse. You can create your own templates and you will be informed about the availability of the products
in your shopping cart. You can load the completed parts lists directly
into Excel or Word.

www.siemens.com/industrymall
Delivery status
When you have sent the order, you will receive a short e-mail confirmation which you can print out or save. With a click on "Carrier", you
will be directly connected to the website of the carrier where you can
easily track the delivery status.
Added value due to additional information
So you have found your product and want more information about it?
In just a few clicks of the mouse, you will arrive at the image data base,
manuals and operating instructions. Create your own user documentation with My Documentation Manager.
Also available are FAQs, software downloads, certificates and
technical data sheets as well as our training programs. In the image
database you will find, depending on the product, 2D/3D graphics,
dimension drawings and exploded drawings, characteristic curves or
circuit diagrams which you can download.
Convinced? We look forward to your visit!

Siemens LV 50 2012

Siemens AG 2012

System Overview

1/2

Degrees of Protection
Meaning of the code numbers

1/3
1/4
1/5

System Cubicles
Introduction
8MF system cubicles
Preconfigured cubicles

1/7

System Lighting
Cubicle lighting, plug-on mounts

1/8

System Air-Conditioning
8MR system air-conditioning
Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 50 2012

Siemens AG 2012

System Overview
Degrees of Protection
Meaning of the code numbers

Overview
Cubicles are installed in the most varied environments, from
office buildings to workshops and manufacturing centers.
SIVACON sicube system cubicles are designed for all these
environments. In their standard versions, they offer the following
degrees of protection:
System cubicles without ventilation: IP40 and IP54
System cubicles with ventilation: IP30 and IP40
Different degrees of protection are available on request.
We are able to supply cubicles with all the degrees of protection
indicated in blue in the table below.
First code
number
0

Degree of protection (protection against contact and foreign


objects)
Description

Explanation

No protection

No particular protection for persons


against accidental contact with live or
moving parts.
No protection of the equipment against
the penetration of solid foreign objects.

Degree of protection (protection against water)


Description

Explanation

No protection

No particular protection

Protection against
vertically falling water
drops

Vertically falling water drops must have


no harmful effects.

Protection against solid Protection against accidental broad


2
foreign objects > 50 mm contact with live or internal moving parts,
e. g. with the hand, but no protection
against deliberate access to these parts. 3
Protection against the penetration of
solid foreign objects with a diameter
greater than 50 mm.

Protection against water Falling water drops must have no harmful


drops falling at an angle effects at any angle up to 15 from the
vertical.
Protection against
spraying water

Water spraying at any angle up to 60


from the vertical must have no harmful
effects.

Protection against
solid foreign objects
> 12 mm

Protection against finger contact with live 4


or internal moving parts.

Protection against
splashing water

Protection against the penetration of


solid foreign objects with a diameter
greater than 2.5 mm.

Water splashing against the equipment


must have no harmful effects,
irrespective of its direction.

Protection against
water jets

Water directed at the equipment from a


nozzle must have no harmful effects,
irrespective of its direction.

Protection against contact with live or


6
internal moving parts with tools, wires or
the like with a thickness greater than
2.5 mm.
7
Protection against the penetration of
solid foreign objects with a diameter
greater than 2.5 mm.

Protection against
flooding

Water must have no harmful effects in


case of temporary flooding.

Protection against
immersion

Water must not ingress to such an extent


that it causes harmful effects when the
equipment is immersed in water in
accordance with the defined pressure
and time conditions.

Protection against contact with live or


8
internal moving parts with tools, wires or
the like with a thickness greater than
1 mm.

Protection against
submersion

Water must not ingress to such an extent


that it causes harmful effects when the
equipment is immersed in water in
accordance with the defined pressure
conditions but for an unspecified time.

Example for
specification of a
degree of protection:

Code letters: IP
First code number: 4
Second code number: 0

Protection against
solid foreign objects
> 2.5 mm

Second
code
number

Protection against
solid foreign objects
> 1 mm

Protection against the penetration of


solid foreign objects with a diameter
greater than 1 mm.
5

Protection against
dust deposits

Full protection against contact with live


or internal moving parts.
Protection against harmful dust deposits.
The ingress of dust is not fully prevented,
but dust may not enter to such an extent
that the functioning of the device is
impaired.

Protection against
dust ingress

Full protection against contact with live


or internal moving parts.
No ingress of dust.

1/2

Siemens LV 50 2012

Siemens AG 2012

System Overview
System Cubicles
Introduction

Overview
SIVACON sicube offers a modular system for unequipped,
empty enclosures. The system cubicles can be used in different
application areas and environments.
Degrees of protection
Available degrees of protection as standard:
System cubicles without ventilation: IP40 and IP54
System cubicles with ventilation: IP20 to IP40
Further degrees of protection are available upon request.

Application
SIVACON sicube 8MF system cubicles are designed especially
for:
Open- and closed-loop control technology
Power electronics
Data systems
Preconfigured cubicles
SIVACON sicube 8MF system cubicles are also available for
special applications, e. g. in special sizes:

Available dimensions

8MF6 earthquake-resistant versions

Minimum and Maximum sizes:


Height: From 1800 mm to 2200 mm
Width: From 600 mm to 1200 mm
Depth: From 400 mm to 800 mm
Special sizes available on request

Applications:
In nuclear power plants
In case of increased vibrations (e. g. on excavators)
In areas at risk of earthquakes

The exact graduations can be found in "Order designations of


the standard versions", see page 2/2.

Measures for enhancing electromagnetic compatibility (EMC)


are becoming more and more important, both for individual
devices and complete systems:
Increasing processing speeds of communication systems
Growing complexity of plants
Contact between different systems working in a plant
Different power levels
More and more external interference sources

Transport
Cubicles are dispatched ex works on transport skids, or in the
case of cubicle suites, on transport bases.
Structure
A system cubicle comprises the following basic elements:
Cubicle rack
Enclosures
Cubicle expansions

EMC versions

A standard cubicle is supplied with the following standard


enclosure parts:
Rear panel
Plain roof
Door with espagnolette lock and lock inserts
Side panels (in case of stand-alone installation)
Versions
Cutouts for customized components
Double-wing doors
Instrument covers
Additional doors
Roofs with busbar holders
Doors with ventilation slots
Perforated ventilation covers
Mounted units for cubicle air-conditioning
Possible cubicle modifications see chapter 5.

Siemens LV 50 2012

1/3

Siemens AG 2012

System Overview
System Cubicles
8MF system cubicles

Overview

Application
8MF system cubicles are intended for the installation of devices
and equipment for electronic and conventional open- and
closed-loop control systems.
The design allows cubicle racks for 19-inch installations for the
most varied industrial electronics applications, alongside distribution modules for power distribution.
Specific design measures permit 8MF6 cubicles with the dimensions H W = 2200 900 mm or 2200 600 mm to be supplied
as earthquake-resistant versions for operation in nuclear power
stations (see "8MF6 earthquake-resistant cubicles" on the previous page 1/3).

8MF system cubicle

Design
8MF2: Completely welded cubicle
8MF5: Welded side frame sections, screwed on lateral stays,
delivery form: unassembled
8MF6: Welded side frame sections, screwed on lateral stays,
delivery form: assembled
Side and rear panels add 9 mm to the frame dimensions
Ground clearance of the doors: 63 mm
Concealed hinges with an opening angle of 180
(130 for cubicle suites)
Trim strips for labeling and integration of signaling lights

1/4

Siemens LV 50 2012

Siemens AG 2012

System Overview
System Cubicles
Preconfigured cubicles

Overview
Ventilated cubicles 8MF2 (IP30/40)
Compact designs and high packing densities demand special
measures for heat dissipation. We offer ventilated cubicles in a
preconfigured version, i. e. the complete cubicle can be ordered
with one order number.

NSE0_01344

Features
Perforated roof plates
Doors with 5 rows of ventilation slots
High air throughput per unit of area thanks to special
SBL ventilation design
IP30 and IP40 degrees of protection available

IP54 cubicles
Special ambient conditions require a high degree of protection.
Particularly its protection against splashing water makes this
cubicle solution suitable for use on production lines and in other
areas with sprinkler systems.

NSE0_01371a

Features
Seals on all enclosure parts

Siemens LV 50 2012

1/5

Siemens AG 2012

System Overview
System Cubicles
Preconfigured cubicles
EMC cubicles
To ensure a system's EMC, it is necessary that its devices emit
only limited interference and are at the same time immune as far
as possible to external interference.
Features
Cubicle rack and enclosure fully galvanized
Paint finish only on the outer surfaces of doors and rear/side
panels
Conductive seals pre-mounted for doors and rear/side panels
Additional standard base plate

PC cubicles 8MF2
A variant of the 8MF system cubicles can also be ordered as a
PC cubicle. The PC cubicle is a robust construction and is thus
suitable for use in industrial environments.
Features
The standard door is replaced by:
An upper compartment door (monitor cutout with inspection
pane)
A central hinged flap (with telescopic shelf for a keyboard)
A lower compartment door (with shelf for a printer)

Earthquake-resistant cubicles 8MF6


This cubicle is a certified earthquake-resistant system cubicle.
An appropriate weight distribution and center of gravity are
prescribed by the certification The devices and components
installed by the customer must also satisfy the relevant
demands.
Features
Bracing stays at the top and bottom, plus a stay on the side
Base plate with multiple divisions and foam rubber profile
Corner bracings at the top and bottom
Reinforcement plate

NSE0_02135

1/6

Siemens LV 50 2012

Siemens AG 2012

System Overview
System Lighting
Cubicle lighting, plug-on mounts

Overview
Plug-on mounts
If a cubicle light is provided with a plug-on mount, it remains
immune to vibration and can be removed at any later time
without tools.
If fitted between two plug-on mounts, the cubicle light is fixed
statically to the cubicle. The cubicle light can only be fitted to the
cubicle by using plug-on mounts.

Slimline SL 025 light with motion detector

Cubicle lighting
The cubicle light is specifically suitable for operation in
switchgear and controlgear cubicles.
In the case of lights with a SCHUKO socket outlet, the outlet is
incorporated with an on/off switch or motion detector in the
plastic enclosure.
The flat SL 025 slimline light with motion detector or on/off switch
is ideal for operation in cubicles and enclosures with a high
density of built-in electrical/electronic components.
All lights are fitted with environmentally-friendly energy-saving
lamps.
Rating of energy-saving lamps Rating of conventional incandescent
lamps
9W

60 W

11 W

75 W

20 W

100 W

Spare lamp: Osram SPD1411-2B (100 W)

Siemens LV 50 2012

1/7

Siemens AG 2012

System Overview
System Air-Conditioning
8MR system air-conditioning

Overview
Optimum, extended
air duct for the system
air-conditioning

35 C
Hot air from the
equipment and
busbars

55 C

Cubicle

Cold air
recirculation

25 C

In control cubicles, depending on the ambient conditions


(e. g. heat, cold, air humidity etc.), there may be a tendency to
overheat or for mold to form. In such cases the cubicles should
be air-conditioned. The following air-conditioning equipment is
available for this purpose:
Filter fans
Air conditioners/cooling devices
Heat exchangers, air/air
Heaters/thermostats
When selecting individual air-conditioning components, the
ambient temperature, the power losses of the installed devices,
the maximum permissible device temperatures and the heat
dissipation capacity of the cubicle used are the factors to be
considered. In addition, it is necessary to take into account the
required degree of protection.

NSE0_01390a

System air-conditioning optimum air guidance


Control supply voltage or voltage for switching capacity
24/48 V DC

115 V AC

230 V AC

400/440 V AC

------

-----

-----

--

--

--

--

--

--

--

--

--

100 W ... 1200 W

--

Setting ranges 0 ... +60 C, +32 ... +140 F

--

8MR system air-conditioning


Filter fans
Standard filter fans, IP54 or IP55

With or without additional EMC protection


Cooling capacity 8 W/K ... 282 W/K
Air rate 25 m3/h ... 845 m3/h
Size 92 92 mm to 292 mm 292 mm
Color RAL 7035 or RAL 7032

Roof filter fans, IP44

Cooling capacity 113 W/K ... 242 W/K


Air rate 350 m3/h ... 690 m3/h
Size 430 mm 430 mm to 470 mm 470 mm
Color RAL 7035 or RAL 7032

Air conditioners/cooling devices


For door and side mounting (recessed)
380 ... 5800 W
For roof mounting
410 ... 3850 W
Heat exchangers
Standard
Air/air (at T = 20 K)
For side and door mounting
700 ... 1900 W
Heater units optionally without or with thermostat
10 W ... 150 W
Fan heaters optionally without or with thermostat

Thermostats, hygrostats, hygrotherms, switching modules


Thermostats, optionally NC, NO, CO contacts
Setting ranges -10... +80 C

--

--

Switching capacities up to 16 A

--

Hygrostats, changeover contacts

--

40 ... 95 % relative air humidity

--

--

--

--

--

-----

Hygrotherms, optionally NC, NO, CO contacts

Setting ranges 0 ... 60 C, +32 ... +140 F


50 ... 90 % relative air humidity
Switching capacities 6 (1) A ... 8 (1.6) A
Switching modules 16 A

Available or possible
-- Not available or not possible
On request
The figures in brackets indicate inductive switching capacities.

1/8

Siemens LV 50 2012

Siemens AG 2012

Cubicle Racks
2/2

General data

2/3

Welded cubicle racks

2/5

Screwed cubicle racks

2/8

Cubicle suites

Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 50 2012

Siemens AG 2012

Cubicle Racks
General data

Overview
Scope of delivery

8MF2

8MF5

8MF6

Cubicle racks

Welded,
zinkcor coated and
powder coated

Screwed (unassembled),
zinkcor coated and
powder coated

Screwed (assembled),
zinkcor coated and
powder coated

Side frame profile

Sheet steel 2.5 mm

Sheet steel 2.5 mm

Sheet steel 2.5 mm

Lateral stay profile

Sheet steel 2.5 mm

Sheet steel 4 mm

Sheet steel 4 mm

Surface

Powder coating
Finely textured surface for indoor installation RAL 7032

Standard version

A standard rack is supplied with the


following standard enclosure parts:
Rear panel

Edge-folded, sheet steel 1.5 mm, powder coated

Side panels (for stand-alone


installation only)

Edge-folded, sheet steel 1.5 mm, powder coated

Door

Sheet steel 1.5 mm, powder coated

Sheet steel 1.5 mm, powder coated

Front door (right-hand hinges) or double-wing doors with


minimum width = 1000 mm

Front door (right-hand hinges) or double-wing doors with


minimum width = 1200 mm

Espagnolette lock with double-bit key acc. to DIN 43668

Espagnolette lock with double-bit key acc. to DIN 43668

Lock insert with 3 mm dia. pin, 180 hinges


(opening angle on cubicle suites approx. 130)

Lock insert with 3 mm dia. pin, 180 hinges


(opening angle on cubicle suites approx. 130)

Trim strip

Petrol

Roof plate

Plain, steel sheet 1.5 mm, galvanized

Degree of protection

IP40 according to EN 60529

Paint finish

Powder coated, finely textured surface, for indoor installation


RAL 70321) (other cubicle colors on request)

1)

The colors RAL 7032 and 7035 are identical in price.

Order designations of the standard versions


8MF5 and 8MF6 cubicles (screwed)

8MF2 cubicles (welded)

8 MF 5 7 7 7 7 7
8 MF 2 7 7 7 7 7
Height

1800 mm
2000 mm
2200 mm

Width

600 mm
800 mm
900 mm
1000 mm
1200 mm

Depth

400 mm
600 mm
800 mm

Degree of
protection

IP40
IP54

Installation

Stand-alone installation
with two side panels
Suite installation
without side panels

8 MF 6 7 7 7 7 7
Height

1800 mm
2000 mm
2200 mm

Width

600 mm
800 mm
900 mm
1200 mm

Depth

400 mm
600 mm
800 mm

Degree of
protection

IP40
IP54

Installation

Stand-alone installation
with two side panels

Suite installation
without side panels

8
0
2
6
8
9
0
2
4
6
8
4
5

8
0
2
6
8
9
2
4
6
8
4
5

Addition to the rack dimension due to side panels, rear panels and doors
Example:
Addition to the rack dimensions
Width in mm

Depth in mm

Per side panel

--

Per rear panel

--

Per door

--

25

2/2

Siemens LV 50 2012

If a cubicle is ordered with side panels on the left and right, a


rear panel and a front door, the final dimensions will be larger by
18 mm for the width and by 34 mm for the depth.

Siemens AG 2012

Cubicle Racks
Welded cubicle racks

Overview
8MF2 system cubicles
Features
Cubicle rack comprising two side frame sections and four lateral stays
Fully welded
Profile of the side frames folded 5 times

Scope of delivery

NSE0_02133

A standard rack is delivered with the following standard enclosure parts


Rear panel
Plain roof
Door with espagnolette lock and lock inserts
Side panels (in case of stand-alone installation)
Mounting of the enclosure parts using self-tapping screws;
no additional grounding measures are necessary therefore
Fitting of devices and internal partitions
Internal interfaces for partitions and devices:
Two rows of holes with a diameter of 9.2 mm and spacing of
20 mm
Mounting with special bolts and contact washers which
comply with the grounding regulations

2
1
2
3
4

Welded rack
5
Door (right-hand hinge) 6
Side panel
Roof panel

Rear panel
Trim strip

Siemens LV 50 2012

2/3

Siemens AG 2012

Cubicle Racks
Welded cubicle racks

Selection and ordering data


8MF2 standard cubicles (welded)
Height

Width

Depth

DT Stand-alone installation
Order No.

mm

mm

mm

Weight DT Suite installation


per PU*)
Order No.
approx.

kg

Weight
per PU*)
approx.

kg

Degree of protection IP40


1800

2000

2200

600

400
600
800

8MF2 864-4E
8MF2 866-4E
8MF2 868-4E

85.000
90.000
100.000

8MF2 864-4R
8MF2 866-4R
8MF2 868-4R

85.000
90.000
100.000

800

400
600
800

8MF2 884-4E
8MF2 886-4E
8MF2 888-4E

95.000
100.000
110.000

8MF2 884-4R
8MF2 886-4R
8MF2 888-4R

95.000
100.000
110.000

00

400
600
800

8MF2 894-4E
8MF2 896-4E
8MF2 898-4E

100.000
110.000
120.000

8MF2 894-4R
8MF2 896-4R
8MF2 898-4R

100.000
110.000
120.000

1000

400
600
800

8MF2 804-4E
8MF2 806-4E
8MF2 808-4E

100.000
110.000
120.000

8MF2 804-4R
8MF2 806-4R
8MF2 808-4R

100.000
110.000
120.000

1200

400
600
800

8MF2 824-4E
8MF2 826-4E
8MF2 828-4E

115.000
125.000
135.000

8MF2 824-4R
8MF2 826-4R
8MF2 828-4R

115.000
125.000
135.000

600

400
600
800

8MF2 064-4E
8MF2 066-4E
8MF2 068-4E

105.000
105.000
120.000

8MF2 064-4R
8MF2 066-4R
8MF2 068-4R

105.000
105.000
120.000

800

400
600
800

8MF2 084-4E
8MF2 086-4E
8MF2 088-4E

110.000
120.000
165.000

8MF2 084-4R
8MF2 086-4R
8MF2 088-4R

110.000
120.000
165.000

900

400
600
800

8MF2 094-4E
8MF2 096-4E
8MF2 098-4E

125.000
135.000
145.000

8MF2 094-4R
8MF2 096-4R
8MF2 098-4R

125.000
135.000
145.000

1000

400
600
800

8MF2 004-4E
8MF2 006-4E
8MF2 008-4E

130.000
145.000
155.000

8MF2 004-4R
8MF2 006-4R
8MF2 008-4R

130.000
145.000
155.000

1200

400
600
800

8MF2 024-4E
8MF2 026-4E
8MF2 028-4E

145.000
155.000
165.000

8MF2 024-4R
8MF2 026-4R
8MF2 028-4R

145.000
155.000
165.000

600

400
600
800

8MF2 264-4E
8MF2 266-4E
8MF2 268-4E

130.000
135.000
145.000

8MF2 264-4R
8MF2 266-4R
8MF2 268-4R

130.000
135.000
145.000

800

400
600
800

8MF2 284-4E
8MF2 286-4E
8MF2 288-4E

135.000
145.000
175.000

8MF2 284-4R
8MF2 286-4R
8MF2 288-4R

135.000
145.000
175.000

900

400
600
800

8MF2 294-4E
8MF2 296-4E
8MF2 298-4E

140.000
165.000
175.000

8MF2 294-4R
8MF2 296-4R
8MF2 298-4R

140.000
165.000
175.000

1000

400
600
800

8MF2 204-4E
8MF2 206-4E
8MF2 208-4E

165.000
175.000
185.000

8MF2 204-4R
8MF2 206-4R
8MF2 208-4R

165.000
175.000
185.000

1200

400
600
800

8MF2 224-4E
8MF2 226-4E
8MF2 228-4E

185.000
195.000
210.000

8MF2 224-4R
8MF2 226-4R
8MF2 228-4R

185.000
195.000
210.000

Note
Package size for 8MF2 cubicles = 1 unit, i. e. 1 unit or a multiple
thereof can be ordered.
If a door with left-hand hinges is required, add the suffix "-Z" to
the Order No. and "left-hand hinge" to the text.
Special size available on request.
Note the addition to the cubicle dimensions by side panels, rear
panels and doors.
Further information see page 2/2.

2/4

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Racks
Screwed cubicle racks

Overview
8MF5 and 8MF6 system cubicles
4

3
6

Features
Cubicle rack comprising two side frame sections and four lateral stays
Angle-welded side frame
Screwed lateral stays
Profile of the side frames folded 5 times
Type of delivery of the 8MF5: unassembled
Type of delivery of the 8MF6: assembled
The cubicle is secured to the floor using 4 holes with a
diameter of 14.5 mm in both bottom lateral stays (see the
Configuration CD at the end of the appendix).

NSE0_02132

Scope of delivery

2
1
2
3
4

Screwed rack
5
Door (right-hand hinge) 6
Side panel
Roof panel

Rear pane
Trim strip

A standard rack is delivered with the following standard


enclosure parts
Rear panel
Plain roof
Door with espagnolette lock and lock inserts
Side panels (in case of stand-alone installation)
Mounting of the enclosure parts using self-tapping screws;
no additional grounding measures are necessary therefore
Fitting of devices and internal partitions
Internal interfaces for partitions and devices:
Two rows of holes with a diameter of 9.2 mm and spacing of
20 mm
Mounting with special bolts and contact washers which
comply with the grounding regulations

Siemens LV 50 2012

2/5

Siemens AG 2012

Cubicle Racks
Screwed cubicle racks

Selection and ordering data


8MF5 standard cubicles (screwed, unassembled)
Height

Width

Depth

DT Stand-alone installation
Order No.

mm

mm

mm

Weight DT Suite installation


per PU*)
Order No.
approx.

kg

Weight
per PU*)
approx.

kg

Degree of protection IP40


1800

2000

2200

600

400
600
800

8MF5 864-4E
8MF5 866-4E
8MF5 868-4E

85.000
90.000
100.000

8MF5 864-4R
8MF5 866-4R
8MF5 868-4R

85.000
90.000
100.000

800

400
600
800

8MF5 884-4E
8MF5 886-4E
8MF5 888-4E

95.000
100.000
110.000

8MF5 884-4R
8MF5 886-4R
8MF5 888-4R

95.000
100.000
110.000

900

400
600
800

8MF5 894-4E
8MF5 896-4E
8MF5 898-4E

100.000
110.000
120.000

8MF5 894-4R
8MF5 896-4R
8MF5 898-4R

100.000
110.000
120.000

1200

400
600
800

8MF5 824-4E
8MF5 826-4E
8MF5 828-4E

115.000
125.000
135.000

8MF5 824-4R
8MF5 826-4R
8MF5 828-4R

115.000
125.000
135.000

600

400
600
800

8MF5 064-4E
8MF5 066-4E
8MF5 068-4E

105.000
105.000
120.000

8MF5 064-4R
8MF5 066-4R
8MF5 068-4R

105.000
105.000
120.000

800

400
600
800

8MF5 084-4E
8MF5 086-4E
8MF5 088-4E

110.000
120.000
165.000

8MF5 084-4R
8MF5 086-4R
8MF5 088-4R

110.000
120.000
165.000

900

400
600
800

8MF5 094-4E
8MF5 096-4E
8MF5 098-4E

125.000
135.000
145.000

8MF5 094-4R
8MF5 096-4R
8MF5 098-4R

125.000
135.000
145.000

1200

400
600
800

8MF5 024-4E
8MF5 026-4E
8MF5 028-4E

145.000
155.000
165.000

8MF5 024-4R
8MF5 026-4R
8MF5 028-4R

145.000
155.000
165.000

600

400
600
800

8MF5 264-4E
8MF5 266-4E
8MF5 268-4E

130.000
135.000
145.000

8MF5 264-4R
8MF5 266-4R
8MF5 268-4R

130.000
135.000
135.000

800

400
600
800

8MF5 284-4E
8MF5 286-4E
8MF5 288-4E

135.000
145.000
175.000

8MF5 284-4R
8MF5 286-4R
8MF5 288-4R

135.000
145.000
175.000

900

400
600
800

8MF5 294-4E
8MF5 296-4E
8MF5 298-4E

140.000
165.000
175.000

8MF5 294-4R
8MF5 296-4R
8MF5 298-4R

140.000
165.000
175.000

1200

400
600
800

8MF5 224-4E
8MF5 226-4E
8MF5 228-4E

185.000
195.000
210.000

8MF5 224-4R
8MF5 226-4R
8MF5 228-4R

185.000
195.000
210.000

Note
Package size for 8MF5 cubicles = 1 unit, i. e. 1 unit or a multiple
thereof can be ordered.
If a door with left-hand hinges is required, add the suffix "-Z" to
the Order No. and "left-hand hinge" to the text.
Note the addition to the cubicle dimensions by side panels, rear
panels and doors.
Further information see page 2/2.

2/6

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Racks
Screwed cubicle racks
8MF6 standard cubicles (screwed, assembled)
Height

Width

Depth

DT Stand-alone installation
Order No.

mm

mm

mm

Weight DT Suite installation


per PU*)
Order No.
approx.

kg

Weight
per PU*)
approx.

kg

Degree of protection IP40


1800

2000

2200

600

400
600
800

8MF6 864-4E
8MF6 866-4E
8MF6 868-4E

85.000
90.000
100.000

8MF6 864-4R
8MF6 866-4R
8MF6 868-4R

85.000
90.000
100.000

800

400
600
800

8MF6 884-4E
8MF6 886-4E
8MF6 888-4E

95.000
100.000
110.000

8MF6 884-4R
8MF6 886-4R
8MF6 888-4R

95.000
100.000
110.000

900

400
600
800

8MF6 894-4E
8MF6 896-4E
8MF6 898-4E

100.000
110.000
120.000

8MF6 894-4R
8MF6 896-4R
8MF6 898-4R

100.000
110.000
120.000

1200

400
600
800

8MF6 824-4E
8MF6 826-4E
8MF6 828-4E

115.000
125.000
135.000

8MF6 824-4R
8MF6 826-4R
8MF6 828-4R

115.000
125.000
135.000

600

400
600
800

8MF6 064-4E
8MF6 066-4E
8MF6 068-4E

105.000
105.000
120.000

8MF6 064-4R
8MF6 066-4R
8MF6 068-4R

105.000
105.000
120.000

800

400
600
800

8MF6 084-4E
8MF6 086-4E
8MF6 088-4E

110.000
120.000
165.000

8MF6 084-4R
8MF6 086-4R
8MF6 088-4R

110.000
120.000
165.000

900

400
600
800

8MF6 094-4E
8MF6 096-4E
8MF6 098-4E

125.000
135.000
145.000

8MF6 094-4R
8MF6 096-4R
8MF6 098-4R

125.000
135.000
145.000

1200

400
600
800

8MF6 024-4E
8MF6 026-4E
8MF6 028-4E

145.000
155.000
165.000

8MF6 024-4R
8MF6 026-4R
8MF6 028-4R

145.000
155.000
165.000

600

400
600
800

8MF6 264-4E
8MF6 266-4E
8MF6 268-4E

130.000
135.000
145.000

8MF6 264-4R
8MF6 266-4R
8MF6 268-4R

130.000
135.000
145.000

800

400
600
800

8MF6 284-4E
8MF6 286-4E
8MF6 288-4E

135.000
145.000
175.000

8MF6 284-4R
8MF6 286-4R
8MF6 288-4R

135.000
145.000
175.000

900

400
600
800

8MF6 294-4E
8MF6 296-4E
8MF6 298-4E

140.000
165.000
175.000

8MF6 294-4R
8MF6 296-4R
8MF6 298-4R

140.000
165.000
175.000

1200

400
600
800

8MF6 224-4E
8MF6 226-4E
8MF6 228-4E

185.000
195.000
210.000

8MF6 224-4R
8MF6 226-4R
8MF6 228-4R

185.000
195.000
210.000

Note
Package size for 8MF6 cubicles = 1 unit, i. e. 1 unit or a multiple
thereof can be ordered.
If a door with left-hand hinges is required, add the suffix "-Z" to
the Order No. and "left-hand hinge" to the text.
Special size available on request.
Note the addition to the cubicle dimensions by side panels, rear
panels and doors.
Further information see page 2/2.

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

2/7

Siemens AG 2012

Cubicle Racks
Cubicle suites

Selection and ordering data


We offer two delivery options for cubicles:
individual cubicles for side-by-side installation by the
customer, or
fully assembled cubicle suites (assembly drawings required).

The following order number must be quoted when ordering


cubicle suites.

2
Version

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

Cubicle suites (screwing together of two cubicles to make a cubicle suite)


In degree of protection IP40

8MF9 100

1 unit

0.150

In degree of protection IP54

8MF9 101

1 unit

0.825

Example of an order using order numbers


You want to order a cubicle suite comprising three 8MF2 cubicles with the dimensions
Height Width Depth = 2000 800 600 mm,
for side-by-side installation, in degree of protection IP40, with
plinth, two side panels and interior cubicle expansions.
This would require the following order, see table on the right.
Note
If required, send a cubicle interior expansion diagram with your
order.

Item Description

Order No.

1.1

8MF2 086-4R

1.2
1.3
1.4

Standard cubicle (welded), degree of prot. IP40,


H W D 2000 800 600 mm
Side panel on left
Plinth, H = 100 mm
Mounting panel

2.1

Cubicle suite in degree of protection IP40

8MF9 100

3.1
3.2

Standard cubicle (welded), degree of prot. IP40, 8MF2 086-4R


H W D 2000 800 600 mm
Plinth, H = 100 mm
8MF4 016

4.1

Cubicle suite in degree of protection IP40

5.1

Standard cubicle (welded), degree of prot. IP40, 8MF2 086-4R


H W D 2000 800 600 mm
Plinth, H = 100 mm
8MF4 016
Side panel on right
8MF4 131

5.2
5.3

8MF4 131
8MF4 016
8MF4 511

8MF9 100

All cubicles fully assembled

Accessories
Version

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

Assembly kits
The assembly kit for cubicle interconnection comprises:

8MF9 113

1 unit

0.150

8MF9 115

1 unit

0.056

12 bolts size M8 15
12 hexagonal nuts size M8, DIN 4032-8
12 contact washers size 10, SN 70093

Sealing material
Set of seals to interconnect two cubicles with degree of protection IP54

2/8

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Enclosures

3/2
3/3

General Data
Introduction
Modification of enclosure parts
with ventilation options

3/7

Doors
Doors with ventilation openings
Double-wing doors
Compartment doors
for cubicle width 600 to 900 mm
Rear doors

3/9

Panels
Side panels and mounted windows

3/10

Bases
Base plates and foam rubber profiles

3/11
3/12
3/13
3/14

Roofs
Roof plates for cable entry
Busbar roof plates
Perforated roof plates
Perforated ventilation roofs

3/15
3/16

Accessories
Locking systems
Defined openings

3/4
3/5
3/6

Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 50 2012

Siemens AG 2012

Enclosures
General Data
Introduction

Overview
Scope of delivery
1

Busbar roof
panel

Side cover
panel for
busbar roof
Roof panel
for cable entry
Perforated ventilation
roof

3
4

Perforated roof panel

SBL ventilation roof


panel

Double-wing
compartment door
Ventilation slots

If special enclosure parts are ordered for a standard cubicle,


they will be delivered in place of the standard enclosure parts.

Note

Symmetrical doublewing door

10

Asymmetrical double-wing
door

11

Rack

Note the addition to the cubicle dimensions by side panels, rear


panels and doors.
Further information see page 2/2.

NSE0_01340a

A standard cubicle rack is supplied with the following standard


enclosure parts:
Rear panel
Plain roof
Door with espagnolette lock and lock inserts

10
9

11

10
9
8
7

3/2

Siemens LV 50 2012

Siemens AG 2012

Enclosures
General Data
Modification of enclosure parts
with ventilation options

Overview
The customizing of enclosure parts for cubicles is one of our
major strengths. Depending on the required degree of
protection, ventilation slots or gills can be incorporated directly
into doors or side/rear panels.
Ordering examples for customized enclosure parts
Example
An 8MF cubicle (8MF2266-4R) in degree of protection IP20 can
look as follows:
Door with six rows of 8MF ventilation slots, four cutouts for
measuring instruments and three holes for command devices
plus a perforated roof plate or a ventilation roof plate.
In this case the following must be ordered:

3
8MF ventilation slots with ventilation cross-section, see page 3/4.

Item

Designation

Qty

Order No.

1.1

Cubicle

8MF2 266-4R

1.2

Customizing basic price for door

1.3

Row of ventilation slots, IP20


6 times per row

1.4

Small rectangular cutout

1.5

Single hole

1.6

Perforated ventilation roof in IP20 in


place of standard roof plate

Overall height of 8MF cubicle Max. possible rows of


8MF ventilation slots
mm
1800

15

2000

17

2200

19

Holes/cutouts/bolts

Dimensions

Single hole
Small; round/square
Large; round/square

Up to 30 mm
Over 30 mm

Rectangular cutouts
Small
Large

Sum of height and width < 0.5 m


Sum of height and width > 0.5 m

With window
With Plexiglas insert

Sum of height and width < 0.5 m


Sum of height and width > 0.5 m

For connector holders


(Harting connectors)

40 mm 108 mm
(incl. 4 times fastening holes, 3.5 mm)

Bolts
Additional welding bolt

M6 20 mm or M4 10 mm

8MF3 441

Ventilation versions
Row of ventilation slots for 8MF,
cubicle door, rear panel

Width in mm

Ventilation slots in IP20

500
600
800
900

Ventilation slots in IP30/40


(with grille backing)

Ventilation slots with Masterdrive


perforation in IP20

Row of ventilation gills for 8MF,


cubicle door, rear panel and side
panel

500
600
800
900
500
600
800
900
Version

Dimensions in mm
SBL ventilation gills in IP23

60 12 5
80 12 5

SBL ventilation gills in IP33

80 12 4

Siemens LV 50 2012

3/3

Siemens AG 2012

Enclosures
Doors
Doors with ventilation openings

Overview
All door versions can be equipped with ventilation openings,
see ordering notes on page 3/3.
Dimensions of the ventilation slots
8MF ventilation with "Masterdrive" perforation (25 7.5 mm)

8MF ventilation slots (75 8 mm)


)

For cubicle door with Ventilation cross-section


width
per row of ventilation slots
mm

For cubicle door with Ventilation cross-section


width
per 20 rows of ventilation
slots

cm

mm

IP201)

120
180
210
216
240

1913
2662
3000
3075
3826

Dimensions

Steel sheet thickness

mm

mm

Backed up with frame and fine-meshed grille in order to increase the


degree of protection to IP30/40.

Ventilation gills

IP23
80 12 5

1.5

IP33/43 (with grille backing)


80 12 4

NSE0_01348a

1)

600
800
900
1000
1200

NSE0_01347

NSE0_01346

600
800
900
1000
1200

cm

IP30

3/4

Siemens LV 50 2012

1.5

Siemens AG 2012

Enclosures
Doors
Double-wing doors

Overview
Double-wing doors are available as
Symmetrically divided double-wing doors and
Asymmetrically divided double-wing doors
In both versions the espagnolette lock is fitted in the right-hand
door.
If the double-wing door is required with left-hand hinges, add the
suffix "-Z" to the Order No. and "left-hand hinge" to the text.
Other divisions on request.

Selection and ordering data


Symmetrically divided double-wing doors
Cubicle height

Cubicle width

mm

mm

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

Degree of protection IP40


1800

800
900

8MF3 040
8MF3 041

1 unit
1 unit

5.000
5.000

2000

800
900

8MF3 042
8MF3 043

1 unit
1 unit

5.000
5.000

2200

800
900

8MF3 044
8MF3 045

1 unit
1 unit

5.000
5.000

1800

800
900

8MF3 046
8MF3 047

1 unit
1 unit

5.000
5.000

2000

800
900

8MF3 048
8MF3 050

1 unit
1 unit

5.000
5.000

2200

800
900

8MF3 051
8MF3 052

1 unit
1 unit

5.000
5.000

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

NSE0_01271

Degree of protection IP54

Asymmetrically divided double-wing doors


Cubicle height

Cubicle width

mm

mm

kg

NSE0_01272

Degree of protection IP40


1800

800
900
1000
1200

8MF3 053
8MF3 054
8MF3 055
8MF3 056

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

2000

800
900
1000
1200

8MF3 057
8MF3 058
8MF3 121
8MF3 122

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

2200

800
900
1000
1200

8MF3 123
8MF3 124
8MF3 125
8MF3 126

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

1800

800
900
1000
1200

8MF3 127
8MF3 128
8MF3 130
8MF3 131

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

2000

800
900
1000
1200

8MF3 132
8MF3 133
8MF3 134
8MF3 135

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

2200

800
900
1000
1200

8MF3 136
8MF3 137
8MF3 138
8MF3 140

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

Degree of protection IP54

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

3/5

Siemens AG 2012

Enclosures
Doors
Compartment doors
for cubicle width 600 to 900 mm

Overview

NSE0_01341

Dimensions
Various divisions are possible
Ground clearance: 63 mm
Distance to top edge of cubicle: 6.3 mm
Distance between the compartment doors: 26 mm
Espagnolette lock with 3 mm double-bit
Types on request

3/6

Siemens LV 50 2012

Siemens AG 2012

Enclosures
Doors
Rear doors

Overview
Rear doors
For rear access
Configured as a double door for a cubicle width of 1000 mm
and more

Selection and ordering data


Rear standard doors
.

Cubicle height

Cubicle width

mm

mm

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

NSE0_01275

Degree of protection IP40


1800

600
800
900
1000
1200

8MF3 200
8MF3 201
8MF3 202
8MF3 203
8MF3 204

1 unit
1 unit
1 unit
1 unit
1 unit

15.000
15.000
15.000
15.000
15.000

2000

600
800
900
1000
1200

8MF3 206
8MF3 207
8MF3 208
8MF3 210
8MF3 211

1 unit
1 unit
1 unit
1 unit
1 unit

15.000
15.000
15.000
15.000
15.000

2200

600
800
900
1000
1200

8MF3 212
8MF3 213
8MF3 214
8MF3 215
8MF3 216

1 unit
1 unit
1 unit
1 unit
1 unit

15.000
15.000
15.000
15.000
15.000

1800

600
800
900
1000
1200

8MF3 220
8MF3 221
8MF3 222
8MF3 223
8MF3 224

1 unit
1 unit
1 unit
1 unit
1 unit

15.000
15.000
15.000
15.000
15.000

2000

600
800
900
1000
1200

8MF3 226
8MF3 227
8MF3 228
8MF3 230
8MF3 231

1 unit
1 unit
1 unit
1 unit
1 unit

15.000
15.000
15.000
15.000
15.000

2200

600
800
900
1000
1200

8MF3 232
8MF3 233
8MF3 234
8MF3 235
8MF3 236

1 unit
1 unit
1 unit
1 unit
1 unit

15.000
15.000
15.000
15.000
15.000

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

Degree of protection IP54

Rear, symmetrically divided double-wing doors


.

Cubicle height

Cubicle width

mm

mm

kg

Degree of protection IP40


1800

800
900

8MF3 240
8MF3 241

1 unit
1 unit

25.000
25.000

2000

800
900

8MF3 242
8MF3 243

1 unit
1 unit

25.000
25.000

2200

800
900

8MF3 244
8MF3 245

1 unit
1 unit

25.000
25.000

1800

800
900

8MF3 246
8MF3 247

1 unit
1 unit

25.000
25.000

2000

800
900

8MF3 248
8MF3 250

1 unit
1 unit

25.000
25.000

2200

800
900

8MF3 251
8MF3 252

1 unit
1 unit

25.000
25.000

NSE0_01271

Degree of protection IP54

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

3/7

Siemens AG 2012

Enclosures
Doors
Rear doors
Rear, asymmetrically divided double-wing doors
Cubicle height

Cubicle width

mm

mm

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

Degree of protection IP40

NSE0_01272

3/8

1800

800
900
1000
1200

8MF3 253
8MF3 254
8MF3 255
8MF3 256

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

2000

800
900
1000
1200

8MF3 257
8MF3 258
8MF3 321
8MF3 322

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

2200

800
900
1000
1200

8MF3 323
8MF3 324
8MF3 325
8MF3 326

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

1800

800
900
1000
1200

8MF3 327
8MF3 328
8MF3 330
8MF3 331

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

2000

800
900
1000
1200

8MF3 332
8MF3 333
8MF3 334
8MF3 335

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

2200

800
900
1000
1200

8MF3 336
8MF3 337
8MF3 338
8MF3 340

1 unit
1 unit
1 unit
1 unit

25.000
25.000
25.000
25.000

Degree of protection IP54

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Enclosures
Panels
Side panels and mounted windows

Overview
Side panels
Side panels serve to complete a cubicle or cubicle suite. If an
assembled side panel is ordered, but no side is specified, the

side panel will be assembled on the right-hand side of the


cubicle.

Selection and ordering data


Side panels
Cubicle height

Cubicle depth

mm

mm

Order No.

PS*/
P. unit

DT

Weight
per PU
approx.
kg

Side panels
Versions

NSE0_01287

Degree of protection IP40


- 1800

- 400
- 600
- 800

8MF4 120
8MF4 121
8MF4 122

1 unit
1 unit
1 unit

8.404
12.631
16.858

- 2000

- 400
- 600
- 800

8MF4 130
8MF4 131
8MF4 132

1 unit
1 unit
1 unit

9.334
28.009
37.405

- 2200

- 400
- 600
- 800

8MF4 140
8MF4 141
8MF4 142

1 unit
1 unit
1 unit

20.473
16.700
41.151

- 1800

- 400
- 600
- 800

8MF4 125
8MF4 126
8MF4 127

1 unit
1 unit
1 unit

8.560
12.787
17.014

- 2000

- 400
- 600
- 800

8MF4 135
8MF4 136
8MF4 137

1 unit
1 unit
1 unit

9.490
28.165
18.886

- 2200

- 400
- 600
- 800

8MF4 145
8MF4 146
8MF4 147

1 unit
1 unit
1 unit

20.629
30.967
20.759

Degree of protection IP54

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

3/9

Siemens AG 2012

Enclosures
Bases
Base plates and foam rubber profiles

Overview
If the cubicle is installed on a closed base frame, it achieves
degree of protection IP20. If a one-piece base plate is used,
the degree of protection of the cubicle is increased to IP40.
Customer-specific holes (e. g. heavy-gauge threaded joints)
permit cable entry.

Base plates with single or multiple subdivisions possess


degree of protection IP40 (without cable entry). If a higher
degree of protection is required, it is recommended to
incorporate a foam rubber profile.
Further base plate designs, e. g. base plates for cable entry,
on request.

Selection and ordering data


Cubicle width

Cubicle depth

mm

mm

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

NSE0_01284

One-piece base plates (standard)


600

400
600
800

8MF4 060
8MF4 061
8MF4 062

1 unit
1 unit
1 unit

2.344
3.758
5.154

800

400
600
800

8MF4 065
8MF4 066
8MF4 067

1 unit
1 unit
1 unit

3.194
5.084
6.964

900

400
600
800

8MF4 070
8MF4 071
8MF4 072

1 unit
1 unit
1 unit

3.574
5.694
7.824

1000

400
600
800

8MF4 073
8MF4 074
8MF4 075

1 unit
1 unit
1 unit

3.943
6.264
8.369

1200

400
600
800

8MF4 076
8MF4 077
8MF4 078

1 unit
1 unit
1 unit

4.294
7.144
5.324

600

400
600
800

8MF4 080
8MF4 081
8MF4 082

1 unit
1 unit
1 unit

3.564
5.094
6.544

800

400
600
800

8MF4 085
8MF4 086
8MF4 087

1 unit
1 unit
1 unit

4.894
7.054
8.934

900

400
600
800

8MF4 090
8MF4 091
8MF4 092

1 unit
1 unit
1 unit

5.514
7.944
10.074

1000

400
600
800

8MF4 093
8MF4 094
8MF4 095

1 unit
1 unit
1 unit

6.084
8.747
11.060

1200

400
600
800

8MF4 096
8MF4 097
8MF4 098

1 unit
1 unit
1 unit

5.514
8.534
11.374

600

600
800

8MF4 101
8MF4 102

1 unit
1 unit

6.823
8.966

800

600
800

8MF4 106
8MF4 107

1 unit
1 unit

8.683
11.376

900

600
800

8MF4 111
8MF4 112

1 unit
1 unit

9.611
12.578

1000

600
800

8MF4 114
8MF4 115

1 unit
1 unit

11.042
14.284

1200

600
800

8MF4 117
8MF4 118

1 unit
1 unit

13.012
16.804

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF3 500

1 unit

0.025

NSE0_01285

Base plates with single sub-division

Base plates with multiple sub-divisions

NSE0_01286

Base plates

Foam rubber profile


Cubicle width

3/10

Cubicle depth

mm

mm

Foam rubber 20 20

1800

Siemens LV 50 2012

kg

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Enclosures
Roofs
Roof plates for cable entry

Overview
A rectangular cutout (with an angled panel fold along the rear
edge) enables cables to be routed into the cubicle. With the aid
of a similarly angled slide plate, the remaining gap can be
closed down to the maximum cable diameter.
This roof plate (without cable entry) has degree of protection
IP40. If a higher degree of protection is required, it is
recommended to use a foam rubber profile or to foam out the
remaining gap.

Selection and ordering data


Cubicle width

Cubicle depth

mm

mm

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

NSE0_01278

Degree of protection IP40


600

400
600
800

8MF3 480
8MF3 481
8MF3 482

1 unit
1 unit
1 unit

1.000
1.000
1.000

800

400
600
800

8MF3 485
8MF3 486
8MF3 487

1 unit
1 unit
1 unit

1.000
1.000
1.000

900

400
600
800

8MF3 490
8MF3 491
8MF3 492

1 unit
1 unit
1 unit

1.000
1.000
1.000

1000

400
600
800

8MF3 493
8MF3 494
8MF3 495

1 unit
1 unit
1 unit

1.000
1.000
1.000

1200

400
600
800

8MF3 496
8MF3 497
8MF3 498

1 unit
1 unit
1 unit

1.000
1.000
1.000

Cubicle width

Cubicle depth

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF3 500

1 unit

0.025

Foam rubber profile

mm

mm

Foam rubber 20 20

1800

* You can order this quantity or a multiple thereof.

kg

Siemens LV 50 2012

3/11

Siemens AG 2012

Enclosures
Roofs
Busbar roof plates

Overview
Roof plate to accommodate a busbar

Side cover panel for busbar roofs

The roof plate for accommodating a busbar can be mounted in


place of the standard closed roof plate.

This cover panel serves to prevent impermissible or accidental


contact with the busbars.

Where it is necessary to mount busbars on the top of the system


cubicle rack, e. g. for space reasons, this roof plate version
serves as an ideal cover.

The same cover panel must be fitted on both sides of the roof.

The cubicle height is increased by 200 mm.

The panel is perforated in the area of the busbars to permit heat


dissipation. Degree of protection IP20.

Selection and ordering data


Roof plates to accommodate a busbar
.

Cubicle width

Cubicle depth

mm

mm

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

Degree of protection IP20


600
800

8MF3 510
8MF3 511

1 unit
1 unit

5.000
5.000

800

600
800

8MF3 513
8MF3 514

1 unit
1 unit

5.000
5.000

900

600
800

8MF3 516
8MF3 517

1 unit
1 unit

5.000
5.000

1000

600
800

8MF3 518
8MF3 520

1 unit
1 unit

5.000
5.000

1200

600
800

8MF3 521
8MF3 522

1 unit
1 unit

5.000
5.000

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

NSE0_01279

600

Side cover panels for busbar roofs


Cubicle depth

kg

mm

Degree of protection IP20


600
800

8MF3 527
8MF3 528

1 unit
1 unit

1.231
1.690

NSE0_01280

The clear passage provided for the busbars is:


Height = 170 mm
Depth = Cubicle depth minus 70 mm.

Other versions on request.

3/12

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Enclosures
Roofs
Perforated roof plates

Overview
The simplest method to dissipate the heat arising in a cubicle
is to provide openings in the roof plate. To achieve degree of
protection IP20, no solid objects with a diameter >12 mm
must be able to penetrate into the cubicle.
In the open area left by the rack, our perforated roof plate has
8 mm 8 mm holes in a 10 mm grid. In the version for degree
of protection IP40, an additional fine-meshed grille is
integrated below the holes.

Selection and ordering data


Cubicle width

Cubicle depth

Effective ventilation
cross-section

mm

mm

cm2

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

NSE0_01276

Degree of protection IP20


600

400
600
800

610
1230
1840

8MF3 400
8MF3 401
8MF3 402

1 unit
1 unit
1 unit

0.100
0.100
0.100

800

400
600
800

870
1740
2610

8MF3 405
8MF3 406
8MF3 407

1 unit
1 unit
1 unit

0.100
0.100
0.100

900

400
600
800

1000
2000
3000

8MF3 410
8MF3 411
8MF3 412

1 unit
1 unit
1 unit

0.100
0.100
0.100

1000

400
600
800

1120
2250
3380

8MF3 413
8MF3 414
8MF3 415

1 unit
1 unit
1 unit

0.100
0.100
0.100

1200

400
600
800

1380
2760
4150

8MF3 416
8MF3 417
8MF3 418

1 unit
1 unit
1 unit

0.100
0.100
0.100

Degree of protection IP40


600

400
600
800

360
710
1070

8MF3 420
8MF3 421
8MF3 422

1 unit
1 unit
1 unit

0.100
0.100
0.100

800

400
600
800

500
1010
1510

8MF3 425
8MF3 426
8MF3 427

1 unit
1 unit
1 unit

0.100
0.100
0.100

900

400
600
800

580
1160
1740

8MF3 430
8MF3 431
8MF3 432

1 unit
1 unit
1 unit

0.100
0.100
0.100

1000

400
600
800

650
1300
1950

8MF3 433
8MF3 434
8MF3 435

1 unit
1 unit
1 unit

0.100
0.100
0.100

1200

400
600
800

800
1600
2410

8MF3 436
8MF3 437
8MF3 438

1 unit
1 unit
1 unit

0.100
0.100
0.100

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

3/13

Siemens AG 2012

Enclosures
Roofs
Perforated ventilation roofs

Overview
In the case of a ventilation roof, a tray is mounted above the
perforated roof plate. This tray prevents vertically falling water
drops from entering the cubicle.

Selection and ordering data


.

Cubicle width

Cubicle depth

Effective ventilation
cross-section

mm

mm

cm2

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

NSE0_01277

Degree of protection IP20


600

400
600
800

610
1230
1840

8MF3 440
8MF3 441
8MF3 442

1 unit
1 unit
1 unit

10.000
10.000
10.000

800

400
600
800

870
1740
2610

8MF3 445
8MF3 446
8MF3 447

1 unit
1 unit
1 unit

10.000
10.000
10.000

900

400
600
800

1000
2000
3000

8MF3 450
8MF3 451
8MF3 452

1 unit
1 unit
1 unit

10.000
10.000
10.000

1000

400
600
800

1120
2250
3380

8MF3 453
8MF3 454
8MF3 455

1 unit
1 unit
1 unit

10.000
10.000
10.000

1200

400
600
800

1380
2760
4150

8MF3 456
8MF3 457
8MF3 458

1 unit
1 unit
1 unit

10.000
10.000
10.000

Degree of protection IP40

3/14

600

400
600
800

360
710
1070

8MF3 460
8MF3 461
8MF3 462

1 unit
1 unit
1 unit

10.000
10.000
10.000

800

400
600
800

500
1010
1510

8MF3 465
8MF3 466
8MF3 467

1 unit
1 unit
1 unit

10.000
10.000
10.000

900

400
600
800

580
1160
1740

8MF3 470
8MF3 471
8MF3 472

1 unit
1 unit
1 unit

10.000
10.000
10.000

1000

400
600
800

650
1300
1950

8MF3 473
8MF3 474
8MF3 475

1 unit
1 unit
1 unit

10.000
10.000
10.000

1200

400
600
800

800
1600
2410

8MF3 476
8MF3 477
8MF3 478

1 unit
1 unit
1 unit

10.000
10.000
10.000

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Enclosures
Accessories
Locking systems

Selection and ordering data


Handles
Version

Locking system

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

Large T-handle

Without

8MF3 110

1 unit

0.125

Small T-handle

With

8MF3 111

1 unit

0.170

Latch handle

Without

8MF3 112

1 unit

0.210

Wing handle

Without

8MF3 113

1 unit

0.227

Wing handle

With

8MF3 114

1 unit

0.300

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

kg

Lock insert/actuator pins


Version

Dimensions

7 Square

8MF3 100

1 unit

0.250

8MF3 101

1 unit

0.250

8MF3 102

1 unit

0.250

8MF3 103

1 unit

0.250

8MF3 104

1 unit

0.250

8MF3 105

1 unit

0.250

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

kg

mm

x Triangular
Double-bit key

Locking systems
For cubicle height

kg
Locking rods
1800
2000
2200

8MF9 060
8MF9 061
8MF9 062

1 unit
1 unit
1 unit

0.380
0.430
0.480

8MF9 065
8MF9 066

1 unit
1 unit

0.364
0.364

8ME8 468
8ME8 473

1 unit
1 unit

0.033
0.023

T-handle without lock


T-handle with lock

8MF9 070
8MF9 071

1 unit
1 unit

0.165
0.165

Latch handle without lock

8MF9 072

1 unit

0.210

Wing handle without lock


Wing handle with lock

8MF9 073
8MF9 074

1 unit
1 unit

0.300
0.350

7 Square, 8 mm

8MF9 081

1 unit

0.015

Double-bit, 3 mm
Double-bit, 5 mm

8MF9 082
8MF9 083

1 unit
1 unit

0.015
0.020

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

Locks
right, with key retainer
left, with key retainer
Espagnolette lock accessory sets
for single-wing door
for double-wing door
Handles

Actuator pins

Keys
Version

Dimensions

kg

Keys are supplied as standard together with all lock- mm


ing systems. The following keys are made available
as replacements:
7 Square

8MF9 052

1 unit

0.200

Double-bit key

3
5

8MF9 055
8MF9 056

1 unit
1 unit

0.200
0.200

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

3/15

Siemens AG 2012

Enclosures
Accessories
Defined openings

Selection and ordering data


Door stay
The door stay holds the door open at 90.
Designation

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MC4 300

1 unit

0.346

mm
Door stay for one door wing

kg

NSE0_01361

NSE0_01292

3/16

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Expansions

4/2
4/3

Exteriors
Base parts
Accessories

4/4
4/8
4/15
4/16
4/17

Interiors
Internal partitions
Mounting of devices
Fastening plates
PE expansion
Accessories

4/18

Outside
Paint finish
Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 50 2012

Siemens AG 2012

Cubicle Expansions
Exteriors
Base parts

Selection and ordering data


Feet
Feet enable the cubicle to be installed at a slightly raised height.
Version

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF4 050

1 unit

1.043

kg
Height = 100 mm. Feet are supplied in the color of the cubicle (1 set = 4 units)

NSE0_01281

Plinths
A plinth increases the floor clearance of the cubicle and
simplifies cable entry and routing. Removal of the side cover
panels permits cables to be routed between cubicles in an
Cubicle width

Cubicle depth

mm

mm

interconnected suite. Plinths are supplied in the color of the


cubicle.
DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

NSE0_01282

Plinth height 100 mm


600

400
600
800

8MF4 010
8MF4 011
8MF4 012

1 unit
1 unit
1 unit

7.100
8.000
8.800

800

400
600
800

8MF4 015
8MF4 016
8MF4 017

1 unit
1 unit
1 unit

8.000
8.800
9.600

900

400
600
800

8MF4 020
8MF4 021
8MF4 022

1 unit
1 unit
1 unit

8.200
9.200
10.000

1000

400
600
800

8MF4 023
8MF4 024
8MF4 025

1 unit
1 unit
1 unit

7.428
8.124
8.982

1200

400
600
800

8MF4 026
8MF4 027
8MF4 028

1 unit
1 unit
1 unit

8.124
9.000
9.768

600

400
600
800

8MF4 030
8MF4 031
8MF4 032

1 unit
1 unit
1 unit

11.500
12.600
14.200

800

400
600
800

8MF4 035
8MF4 036
8MF4 037

1 unit
1 unit
1 unit

12.600
14.200
15.700

900

400
600
800

8MF4 040
8MF4 041
8MF4 042

1 unit
1 unit
1 unit

13.400
14.800
16.400

1000

400
600
800

8MF4 043
8MF4 044
8MF4 045

1 unit
1 unit
1 unit

12.926
14.496
16.066

1200

400
600
800

8MF4 046
8MF4 047
8MF4 048

1 unit
1 unit
1 unit

15.600
17.500
18.600

NSE0_01283

Plinth height 200 mm

4/2

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Expansions
Exteriors
Accessories

Selection and ordering data


Transport aids can be ordered only in conjunction with a cubicle
or cubicle suite.
Transport eyebolts
The transport eyebolts enable a cubicle to be lifted
(according to DIN 580).
Version

Recommendation: the overall crane hook load should


not exceed 500 kg.
DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF4 220

1 unit

1.248

kg
Eyebolts, washers and nuts

Transport brackets
Transport brackets are designed for the crane-lifting of cubicle
suites. Unlike eyebolts, a transport bracket over the whole length
of a cubicle suite is able to ensure that the tensile loads from the
lifting tackle are taken up evenly and simultaneously.
Version

Lengths over 2400 mm on request.

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF4 221

1 unit

6.200

8MF4 222

1 unit

6.200

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF4 225

1 unit

9.800

8MF4 226

1 unit

9.800

kg
1 pair of brackets
per running meter of cubicle
up to 2400 mm in length
in RAL 3000
1 pair of brackets

NSE0_01290

per running meter of cubicle


up to 2400 mm in length
in untreated black plate

Transport rails
Transport rails are mounted above or below cubicles or cubicle
suites. They serve to transport heavy fully configured cubicles or
cubicle suites.
Version

Lengths over 2400 mm on request.

kg
1 pair of rails
per running meter of cubicle
up to 2400 mm in length
in RAL 3000
1 pair of rails

NSE0_01291

per running meter of cubicle


up to 2400 mm in length
in untreated black plate

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

4/3

Siemens AG 2012

Cubicle Expansions
Interiors
Internal partitions

Selection and ordering data


Partition panels/separation panels
Partition/separation panels are installed to separate the cubicles
within a cubicle suite. If an assembled partition/separation panel
is ordered, but no side is specified, the partition/separation
panel will be fitted on the left-hand side of the cubicle.
Cubicle height

Cubicle depth

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

mm

mm

1800

400
600
800

8MF4 150
8MF4 151
8MF4 152

1 unit
1 unit
1 unit

6.071
10.065
14.059

kg

2000

400
600
800

8MF4 160
8MF4 161
8MF4 162

1 unit
1 unit
1 unit

6.764
11.229
15.694

2200

400
600
800

8MF4 170
8MF4 171
8MF4 172

1 unit
1 unit
1 unit

7.456
12.392
17.328

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

NSE0_01288

Further partition panel designs, e. g. with cutouts for plug


connector enclosures, cable entries, etc., on request.

Shelves
Shelves can be supplied for fixed mounting or as withdrawable
shelves on telescopic rails. The maximum width of a shelf is
calculated as the nominal cubicle width minus 60 mm.

Load bearing capacity: 50 kg.

Version

kg

NSE0_01329

Shelves
Versions

Cubicle width in mm

Cubicle depth in mm

Standard shelf (fixed installation)

600

400
600
800

8MF4 800
8MF4 801
8MF4 802

1 unit
1 unit
1 unit

5.418
7.699
9.979

800

400
600
800

8MF4 805
8MF4 806
8MF4 807

1 unit
1 unit
1 unit

7.110
10.175
13.241

600

400
600
800

8MF4 810
8MF4 811
8MF4 812

1 unit
1 unit
1 unit

3.500
4.000
4.400

800

400
600
800

8MF4 815
8MF4 816
8MF4 817

1 unit
1 unit
1 unit

4.200
4.700
5.100

600

400
600
800

8MF4 840
8MF4 841
8MF4 842

1 unit
1 unit
1 unit

4.886
7.697
10.398

800

400
600
800

8MF4 845
8MF4 846
8MF4 847

1 unit
1 unit
1 unit

6.098
9.541
12.474

600

400
600
800

8MF4 850
8MF4 851
8MF4 852

1 unit
1 unit
1 unit

4.700
5.200
5.600

800

400
600
800

8MF4 855
8MF4 856
8MF4 857

1 unit
1 unit
1 unit

4.700
5.200
5.600

Perforated shelves (fixed installation)

Shelves for withdrawal on telescopic rails

Perforated shelves for withdrawal on


telescopic rails

4/4

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Expansions
Interiors
Internal partitions
Telescopic rails
Telescopic rails can be used for maximum shelf withdrawal
(= Cubicle depth minus 20 mm). They are designed for loads up
to 50 kg per rail pair and are retained in their end position.
Busbar length

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

300

8MF4 860

1 unit

0.500

600

8MF4 861

1 unit

0.500

NSE0_01330

mm

kg

If interior expansion parts are to be supplied ready-assembled,


an assembly drawing must be provided.
Supporting bars
Supporting bars permit the cubicle to be subdivided in all
planes.
The U-shaped profile of the supporting bars has 9.2 mm holes at
20 mm intervals.
Version

The supporting bars are mounted either on the cubicle rack or


on other supporting bars using 2 universal fixings each or 2 to 4
mounting brackets.
(Supporting bars are supplied together with the necessary fixing
accessories.)
DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

Supporting bars for cubicle

NSE0_01316

Versions
Height in mm
- 1800
- 2000
- 2200

8ME1 461
8ME1 462
8ME1 463

1 unit
1 unit
1 unit

3.701
4.204
4.636

Width in mm
- 600
- 800
- 900
- 1000
- 1200

8ME1 464
8ME1 465
8ME1 466
8ME1 467
8ME1 468

1 unit
1 unit
1 unit
1 unit
1 unit

1.339
1.771
1.987
2.203
2.634

Depth in mm
- 400
- 600
- 800

8ME1 470
8ME1 471
8ME1 472

1 unit
1 unit
1 unit

0.718
1.150
1.572

Joining sheets/mounting brackets


Joining sheets/mounting brackets are used to fix supporting
bars with two or four M8 screws.
They are suitable for the mounting of supporting bars in all three
planes.
Version

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

Joining sheets

8ME8 812

1 unit

0.090

Mounting brackets
Without spare set
With spare set

8ME8 813
8ME8 811

1 unit
1 unit

0.010
0.075

kg

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

4/5

Siemens AG 2012

Cubicle Expansions
Interiors
Internal partitions
Vertical profile bars
Vertical profile bars divide a cubicle in its width. They have the
same rows of holes as the side frame profile of the 8MF cubicle.
Cubicle height

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

1800

8MF4 380

1 unit

5.702

2000

8MF4 381

1 unit

6.204

2200

8MF4 382

1 unit

7.000

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

kg

NSE0_01319

mm

C-profile bars/cable clamping bars


C-profile bars (EN 50024) permit a cubicle to be divided into
numerous planes to accept loads. C30 is also used as a cable
clamping rail.
The surfaces of the C-profile bars are galvanized and blue
chromated.
Further profiles on request.
Version

kg
C-profile bars for cubicle
NSE0_01320

Versions
C30
- Width in mm:
Y 600
Y 800
Y 900
Y 1000
Y 1200
- Depth in mm:
Y 400
Y 600
Y 800
C40
- Width in mm:
Y 600
Y 800
Y 900
Y 1000
Y 1200
- Depth in mm:
Y 400
Y 600
Y 800
C50
- Width in mm:
Y 600
Y 800
Y 900
Y 1000
Y 1200
- Depth in mm:
Y 400
Y 600
Y 800

4/6

Siemens LV 50 2012

8MF4 400
8MF4 401
8MF4 402
8MF4 403
8MF4 404

1 unit
1 unit
1 unit
1 unit
1 unit

0.445
0.590
0.662
1.534
0.880

8MF4 405
8MF4 406
8MF4 407

1 unit
1 unit
1 unit

0.481
0.747
1.005

8MF4 410
8MF4 411
8MF4 412
8MF4 413
8MF4 414

1 unit
1 unit
1 unit
1 unit
1 unit

0.490
0.649
0.728
1.687
0.968

8MF4 415
8MF4 416
8MF4 417

1 unit
1 unit
1 unit

0.529
0.822
1.106

8MF4 420
8MF4 421
8MF4 422
8MF4 423
8MF4 424

1 unit
1 unit
1 unit
1 unit
1 unit

0.538
0.714
0.801
1.856
1.065

8MF4 425
8MF4 426
8MF4 427

1 unit
1 unit
1 unit

0.582
0.904
1.216

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Expansions
Interiors
Internal partitions
Serrated (toothed) bars
Version

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

Serrated bars
Versions
U-shape, for cubicle width/depth:
- 600 mm
- 800 mm
- 900 mm

NSE0_01336

- 1000 mm
- 1200 mm
Plain, for cubicle width/depth:
- 600 mm
- 800 mm
- 900 mm
- 1000 mm
- 1200 mm
All-round

* You can order this quantity or a multiple thereof.

8MF4 922
8MF4 923
8MF4 924

1 unit
1 unit
1 unit

1.184
1.581
1.605

8MF4 925
8MF4 926

1 unit
1 unit

1.784
2.142

8MF4 932
8MF4 933
8MF4 934

1 unit
1 unit
1 unit

0.984
1.381
1.405

8MF4 935
8MF4 936

1 unit
1 unit

1.584
1.942

On request

Siemens LV 50 2012

4/7

Siemens AG 2012

Cubicle Expansions
Interiors
Mounting of devices

Selection and ordering data


Mounting panels incl. fixing brackets
Mounting panels are used for cubicle installations and for the
mounting of individual devices (also outside the cubicle).
The 2.5 mm galvanized sheet steel panels are depth-adjustable
and are fixed on the cubicle frame (side frame) by way of
4 brackets.
Cubicle height

NSE0_01322

Cubicle width

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

mm

mm

1800

600
800
900
1000
1200

8MF4 500
8MF4 501
8MF4 502
8MF4 503
8MF4 504

1 unit
1 unit
1 unit
1 unit
1 unit

22.010
28.840
32.250
34.651
41.714

kg

2000

600
800
900
1000
1200

8MF4 510
8MF4 511
8MF4 512
8MF4 513
8MF4 514

1 unit
1 unit
1 unit
1 unit
1 unit

24.430
32.050
35.860
39.670
47.290

2200

600
800
900
1000
1200

8MF4 520
8MF4 521
8MF4 522
8MF4 523
8MF4 524

1 unit
1 unit
1 unit
1 unit
1 unit

26.894
35.260
39.470
43.680
39.470

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF4 530

1 unit

0.280

Additional brackets for center fixing of a mounting panel


To further enhance installation stability, additional brackets can
be provided to fix the mounting panel in the center.
The additional fixing brackets cannot be used in conjunction
with side mounting plates.
Version

kg

NSE0_01323

Brackets

4/8

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Expansions
Interiors
Mounting of devices
Mounting plates
Mounting plates (2.5 mm galvanized sheet) are used for cubicle
installations and for the mounting of devices (in installed state
only).

Further dimensions and versions on request.

The plates are screwed to the rear side frame profiles of the
cubicle rack. If they are to be depth-adjustable, they must be
ordered in conjunction with additional vertical supporting bars.
Effective height

Cubicle width

DT Order No.

8MF
mm

PS*/
P. unit

mm

Weight
per PU
approx.
kg

Mounting plates
Versions

NSE0_01324

For all cubicle heights


- 100

600
800
900
1000
1200

8MF4 600
8MF4 601
8MF4 602
8MF4 603
8MF4 604

1 unit
1 unit
1 unit
1 unit
1 unit

2.500
6.167
8.000
9.833
13.500

- 200

600
800
900
1000
1200

8MF4 610
8MF4 611
8MF4 612
8MF4 613
8MF4 614

1 unit
1 unit
1 unit
1 unit
1 unit

4.500
8.167
10.000
11.833
15.500

- 400

600
800
900
1000
1200

8MF4 620
8MF4 621
8MF4 622
8MF4 623
8MF4 624

1 unit
1 unit
1 unit
1 unit
1 unit

6.500
10.167
12.000
13.833
17.500

- 800

600
800
900
1000
1200

8MF4 630
8MF4 631
8MF4 632
8MF4 633
8MF4 634

1 unit
1 unit
1 unit
1 unit
1 unit

8.500
12.167
14.000
15.833
19.500

- 1200

600
800
900
1000
1200

8MF4 640
8MF4 641
8MF4 642
8MF4 643
8MF4 644

1 unit
1 unit
1 unit
1 unit
1 unit

11.000
14.667
16.500
18.333
22.000

600
800
900
1000
1200

8MF4 660
8MF4 661
8MF4 662
8MF4 663
8MF4 664

1 unit
1 unit
1 unit
1 unit
1 unit

24.000
26.000
28.000
30.000
32.000

600
800
900
1000
1200

8MF4 670
8MF4 671
8MF4 672
8MF4 673
8MF4 674

1 unit
1 unit
1 unit
1 unit
1 unit

26.000
28.000
30.000
32.000
34.000

600
800
900
1000
1200

8MF4 680
8MF4 681
8MF4 682
8MF4 683
8MF4 684

1 unit
1 unit
1 unit
1 unit
1 unit

28.000
30.000
32.000
34.000
36.000

For cubicle height 1800 mm


- 1600

For cubicle height 2000 mm


- 1800

For cubicle height 2200 mm


- 2000

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

4/9

Siemens AG 2012

Cubicle Expansions
Interiors
Mounting of devices
Side mounting plates
Side mounting plates (2.5 mm galvanized sheet) are used for
cubicle installations and for the mounting of devices (in installed
state only).

Further dimensions and versions on request.

The plates are screwed between the side frame profiles of the
cubicle rack.
Cubicle depth

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

mm

mm

1800

400
600
800

8MF4 550
8MF4 551
8MF4 552

1 unit
1 unit
1 unit

7.968
14.344
20.728

2000

400
600
800

8MF4 555
8MF4 556
8MF4 557

1 unit
1 unit
1 unit

8.908
16.074
23.238

2200

400
600
800

8MF4 560
8MF4 561
8MF4 562

1 unit
1 unit
1 unit

9.852
17.803
25.753

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

kg

NSE0_01325

Cubicle height

Fixing kits for circuit breakers


The fixing kit comprises two supporting bars for the cubicle
depth and four C 50 profile bars (including fixing accessories).

Further dimensions and versions on request.

NSE0_01326

The bolts, nuts, etc. required for a circuit breaker are not
included in the scope of delivery.
Cubicle depth

Cubicle width

mm

mm

400

600
800
900
1000
1200

8MF4 700
8MF4 701
8MF4 702
8MF4 703
8MF4 704

1 unit
1 unit
1 unit
1 unit
1 unit

4.446
4.960
5.218
5.474
5.990

600

600
800
900
1000
1200

8MF4 710
8MF4 711
8MF4 712
8MF4 713
8MF4 714

1 unit
1 unit
1 unit
1 unit
1 unit

4.960
5.474
5.732
5.988
6.504

800

600
800
900
1000
1200

8MF4 720
8MF4 721
8MF4 722
8MF4 723
8MF4 724

1 unit
1 unit
1 unit
1 unit
1 unit

5.824
6.338
6.596
6.852
7.368

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

kg

Cable ducts according to DIN 43659, form B (slotted)


Unmounted cable ducts are not included in the scope of
delivery!
Duct height

mm

mm

50

50
75
125

On request
On request
On request

75

25
37.5
50
100
125

On request
On request
On request
On request
On request

NSE0_01327

4/10

Duct width

Siemens LV 50 2012

kg

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Expansions
Interiors
Mounting of devices
Standard mounting rails
Specify order requirements in plain text.
Unmounted standard mounting rails are not included in the
scope of delivery!
Designation

Dimensions

DT Order No.

PS*/
P. unit

mm

Weight
per PU
approx.
kg

35 7.5

On request

35 15

On request

G rail to IEC 60715

G32/15/9

On request

NSE0_01328

TH 35 mounting rail 1.5 LL Zn


to IEC 60715

Device plates with standard mounting rail and cable ducts


The device plate is fitted with a standard mounting rail and two
cable ducts (H W = 75 mm 50 mm).
The device plate height is 210 mm.
Designation

Further dimensions and versions on request.

For cubicle width

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF4 570

1 unit

3.000

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

NSE0_01350

mm
Device plate with standard mounting rail
and cable ducts

900

kg

Multi-purpose door bars


The multi-purpose door bars serve both as stiffening bars and as
mounting aids for components (cable clamping, cable ducts,
etc.) which are to be installed in the door.
For cubicle height

Sets

Qty

1800

8MF4 320

1 unit

2.700

kg

2000

8MF4 321

1 unit

3.300

2200

8MF4 322

1 unit

3.650

NSE0_01294

mm

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

4/11

Siemens AG 2012

Cubicle Expansions
Interiors
Mounting of devices
Punched bars
The 19-inch punched bars for captive nuts (or alternatively for
self-tapping screws) possess the same profile as a swing frame.
They are screwed to the upright section of the side frame of a
600 mm wide cubicle.

The row of holes is set back 50 mm from the front edge of the
frame. Additional supporting bars are required to permit
installation in wider cubicles or alternative depth positioning.

For cubicle height

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

NSE0_01331

mm

kg

Punched bars
With M6 captive nut profile
- 1800
- 2000
- 2200

8MF4 870
8MF4 871
8MF4 872

1 unit
1 unit
1 unit

5.658
6.438
6.918

Swing frames (standard)

Hinged frame height


(1 height unit (HU) = 44.45 mm)

the hinging on either the left or the right. The hinging side is
switched by rotating the frame and crossbars. If an order
contains no specifications as to the mounting position, the
swing frame is mounted centrally with left-hand hinges.
Surface: galvanized.
Further swing frame dimensions on request.
For cubicle height

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

mm

kg

3 HU
6 HU
9 HU
12 HU

-----

8MF4 880
8MF4 881
8MF4 882
8MF4 883

1 unit
1 unit
1 unit
1 unit

3.000
3.500
4.500
5.000

35/34 HU
39/38 HU
44/43 HU

1800
2000
2200

8MF4 886
8MF4 887
8MF4 888

1 unit
1 unit
1 unit

15.442
16.242
17.242

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

600
800
900

8MF4 894
8MF4 895
8MF4 896

1 unit
1 unit
1 unit

7.396
9.139
9.803

1000
1200

8MF4 897
8MF4 898

1 unit
1 unit

10.649
12.595

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

Stop

8MF4 820

1 unit

0.105

Grounding strap mm2

8MF4 821

1 unit

0.038

Cable connection strip

8MF4 822

1 unit

4.000

NSE0_01332

Crossbars for swing frames


The set of swing frame crossbars comprises two identical parts
which are to be screwed to the upright stay of the side frame.
Hinged frame crossbars
for cubicle width

Its surface is galvanized.

mm

NSE0_01333

A swing frame comprises welded 19-inch profiles. From a height


of 35 HU, it is possible to install devices weighing up to 160 kg.
In case of standard installation, the opening angle of the swing
frame is 180 and the front row of mounting holes is set back
50 mm from the front edge of the frame. The swing frame is
mounted in the cubicle with a set of crossbars and can be fitted
either centrally or flush to the left or right side, in each case with

Swing frame accessories

kg

kg

4/12

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Expansions
Interiors
Mounting of devices
Heavy-duty swing frames
A heavy-duty swing frame comprises welded 19-inch profiles.
Such swing frames are designed only for the 8MF cubicle
version and are able to accept loads up to 300 kg.

The swing frame is completed with crossbars for cubicle width


900 mm, a lock trim and a cable connection strip. Its surface is
galvanized.
Further swing frame dimensions on request.

Hinged frame height


(1 height unit (HU) = 44.45 mm)

For cubicle width

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF4 885

1 unit

25.000

mm
43 HU

900

kg

NSE0_01351

Lock trims
The lock trim permits easier opening and closing of the swing
frame. It is normally fitted with a handle and espagnolette lock
for a 3 mm double-bit key, though other locking systems are also
possible. Its surface is galvanized.
Hinged frame height
(1 HU = 44.45 mm)

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF4 823

1 unit

8.000

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

250

8MF4 824

1 unit

3.500

400

8MF4 825

1 unit

5.000

kg

NSE0_01352

44 HU/43 HU

19" shelves
19" shelves are intended for fixed installation in the swing frame.
Their surface is galvanized.
Shelf depth

mm

kg

NSE0_01353

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

4/13

Siemens AG 2012

Cubicle Expansions
Interiors
Mounting of devices
Device panel
A device panel is installed either to the left or to the right of the
swing frame and makes up the full width of the cubicle. It can be
used to mount switches, devices and other instruments.
Height
(1 HU = 44.45 mm)

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

8MF4 828

1 unit

11.300

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

kg

NSE0_01354

44 HU/43 HU

Cover plates for swing frames


The swing frame can be fitted with cover plates, frames for 19"
installations and mounting brackets. The surfaces are painted.
Height
(1 HU = 44.45 mm)/
Version
mm

kg

Cover plates
8MF4 831
8MF4 832
8MF4 833

1 unit
1 unit
1 unit

0.600
0.900
1.300

4 HU
5 HU
6 HU

8MF4 834
8MF4 835
8MF4 836

1 unit
1 unit
1 unit

1.700
2.100
2.500

7 HU
44/43 HU

8MF4 837
8MF4 827

1 unit
1 unit

2.900
14.600

For 7 HU

8MF4 838

1 unit

2.500

Mounting brackets for enclosures (7XP20)

8MF4 826

1 unit

0.300

NSE0_01355

1 HU
2 HU
3 HU

Frames

4/14

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Expansions
Interiors
Fastening plates

Overview
Version

DT Order No.

PS*/
P. unit

Weight
per PU
approx.
kg

NSE0_01380

Fastening plates
Lamp plate

8MF4 890

1 unit

1.200

Heater plate

8MF4 891

1 unit

1.500

NSE0_01378

8MF4 892

1 unit

0.300

Door position switch plate

8MF4 893

1 unit

0.200

NSE0_01381

NSE0_01379

Thermostat plate

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

4/15

Siemens AG 2012

Cubicle Expansions
Interiors
PE expansion

Selection and ordering data


Grounding
The use of self-tapping screws for the 8MF cubicles means that
it is not necessary to provide separate grounding of the
enclosure parts or other elements screwed to the cubicle rack.
Grounding cables are only required for the doors and are
already fitted at the factory. Other materials required for
grounding:
Version

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

Grounding plates

8MF4 910

1 unit

0.103

Grounding cables 6 mm2

8MF4 911

1 unit

0.033

Grounding bars
made of copper 30 mm 5 mm
for cubicle width:
600 mm
800 mm
900 mm
1000 mm
1200 mm

8MF4 912
8MF4 913
8MF4 914
8MF4 915
8MF4 916

1 unit
1 unit
1 unit
1 unit
1 unit

0.937
1.246
1.402
1.556
1.865

Grounding bars
made of copper 30 mm 10 mm
for cubicle width:
600 mm
800 mm
900 mm
1000 mm
1200 mm

8MF4 942
8MF4 943
8MF4 944
8MF4 945
8MF4 946

1 unit
1 unit
1 unit
1 unit
1 unit

1.874
2.492
2.804
3.112
3.730

kg

4/16

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Cubicle Expansions
Interiors
Accessories

Selection and ordering data


Circuit diagram pocket
The circuit diagram pocket serves to hold documents to be kept
in the cubicle. Four different versions are available:
A4 upright, depth 30 mm, plastic
A4 upright, depth 75 mm, galvanized sheet steel
A4 horizontal, depth 50 mm, galvanized sheet steel
A3 horizontal, galvanized sheet steel, only for 600 mm doors
in conjunction with multi-purpose door bars

Versions 2 and 3 are mounted on additional welding bolts (must


be specified when ordering the cubicle), version 4 is mounted
on multi-purpose door bars.

Version

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

Plastic

8MF4 301

1 unit

0.010

Sheet steel
A4 upright
A4 horizontal
A3 horizontal

8MF4 302
8MF4 303
8MF4 304

1 unit
1 unit
1 unit

1.472
1.621
2.519

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

Single
1 NO contact + 1 NC contact

8MF4 310

1 unit

0.201

Double
1 NO contact + 2 NC contacts

8MF4 311

1 unit

0.189

DT Order No.

PS*/
P. unit

Weight
per PU
approx.

NSE0_01293

kg

Door position switch


The door position switch serves to switch the cubicle lighting or
any other circuit on and off when the cubicle door is opened and
closed. It is supplied mounted on the hinge side of the cubicle.
Version

kg

Sealing strip
Version

kg
Sealing strips for
Roof plate
Door
Side and rear panel

* You can order this quantity or a multiple thereof.

8MF8 810
8MF8 806
8MF8 807

1 unit
1 unit
1 unit

Siemens LV 50 2012

2.000
5.000
5.000

4/17

Siemens AG 2012

Cubicle Expansions
Outside
Paint finish

Overview
RAL colors
All colors except RAL 7032 are treated as special colors, for
which an additional price is calculated in accordance with the
number of cubicles ordered.
Number of cubicles

Additional price as % of the price of the


ordered cubicle

1 to 3

20 %

4 to 10

18 %

11 to 20

10 %

> 20

No additional price

This additional price refers to a special color for the actual


cubicle, excluding any expansion parts. The additional price is
always calculated on the basis of the IP40 version of the cubicle,
even if the cubicle is ordered with degree of protection IP54.

Munsell colors
All Munsell colors are special colors. Calculation of the
additional price see the table "RAL colors" above.
Siemens standard colors (SN colors)
All colors except SN610 and SN611 are treated as special
colors.
Calculation of the additional price for other SN colors,
see the table "RAL colors" above.
Ordering example
You want two 8MF2 cubicles,
height x width x depth = 2000 mm x 800 mm x 600 mm,
for suite installation, degree of protection IP54,
in the special color RAL 3000.
This would require the following order:
Item

Number

Description

Order No.

1.1

Cubicle

8MF2 086-5R

1.2

Special color RAL 3000

The additional price for the special color amounts to 20 % of the


price for the IP40 version of the cubicle (8MF2 086-4R).

4/18

Siemens LV 50 2012

Siemens AG 2012

Preconfigured Cubicles

5/2

Ventilated Cubicles
8MF2 (IP30/40) cubicles

5/4

IP54 Cubicles
8MF2, 8MF5/6 cubicles

5/9

EMC Cubicles
8MF5, 8MF6 cubicles

5/12

Earthquake-Resistant Cubicles
8MF6 cubicles
Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 50 2012

Siemens AG 2012

Preconfigured Cubicles
Ventilated Cubicles
8MF2 (IP30/40) cubicles

Overview
Compact designs and high packing densities demand special
measures for heat dissipation. We offer ventilated cubicles in a
preconfigured version, i. e. the complete cubicle can be ordered
with one order number.
Features
Perforated roof plates
Doors with 5 rows of ventilation slots
High air throughput per unit of area thanks to special
SBL ventilation design
IP30 and IP40 degrees of protection available
Scope of delivery
8MF2

Standard version
Welded, 2.5 mm steel sheet,
zinkcor coated and powder coated

Cubicle racks
Enclosure parts

Rear panel

Edge-folded,
sheet steel 1.5 mm,
powder coated

Side panels
(can be optionally
ordered)

Edge-folded, sheet steel 1.5 mm, powder coated

Door

With 5 rows of ventilation slots, sheet steel


1.5 mm, powder coated
Front door (right-hand hinges) or
double-wing doors with
minimum width = 1000 mm
Espagnolette lock with double-bit key
acc. to DIN 43668
Lock insert with 3 mm dia. pin
180 hinges (opening angle on cubicle suites
approx. 130)

Trim strip

Petrol

Roof plate

Perforated, sheet steel 1.5 mm, sendzimir coated

Paint finish

Powder coated, finely textured surface,


for indoor installation

NSE0_01392

Cubicle color

RAL 70321) (other cubicle colors on request)

Rack color

RAL 7032

Degree of protection

IP30/IP40 according to EN 60529

1)

The colors RAL 7032 and 7035 according to the Siemens standard are
identical in price

Order designations of the standard versions


8 MF 2 7 7 7 7 7 7
Height

1800 mm
2000 mm
2200 mm

Width

600 mm
800 mm
900 mm
1000 mm
1200 mm

Depth

400 mm
600 mm
800 mm

Degree of
protection

IP30
IP40

Installation

Suite installation

Ventilation

Ventilated

2
1
2
3

5/2

Welded rack
Door (right-hand hinge)
with ventilation slots (SBL)
Side panel

Siemens LV 50 2012

Ventilation roof
panel (SBL)

5
6

Rear panel
Trim strip

8
0
2
6
8
9
0
2
4
6
8
3
4
R
B

Siemens AG 2012

Preconfigured Cubicles
Ventilated Cubicles
8MF2 (IP30/40) cubicles
Ventilation cross-sections in roof plate

Ventilation cross-sections in the doors

Cubicle width Cubicle


depth

Effective ventilation cross-section

mm

cm

mm

Degree of protection IP30


400
600
800

518.40
725.70
933.10

800

400
600
800

710.40
994.60
1278.70

1000

400
600
800

902.40
1263.30
1624.30

400
600
800

1094.40
1532.10
1969.90

1200

Ventilation cross-section
per row of ventilation
slots

mm

cm

IP30
600
800
900
1000
1200

86
131
146
156
172

IP40
NSE0_01344

NSE0_01349

600

For cubicle door


with width

600
800
900
1000
1200

52
72
80
93
104

Degree of protection IP40


600

400
600
800

311.00
435.40
559.80

800

400
600
800

426.40
596.70
767.20

1000

400
600
800

541.40
758.00
974.50

1200

400
600
800

656.60
919.20
1181.90

Siemens LV 50 2012

5/3

Siemens AG 2012

Preconfigured Cubicles
IP54 Cubicles
8MF2, 8MF5/6 cubicles

Overview
Scope of delivery
8MF2

8MF5

8MF6

Cubicle racks

Welded,
zinkcor coated and
powder coated

Screwed (unassembled),
zinkcor coated and
powder coated

Screwed (assembled),
zinkcor coated and
powder coated

Side frame profile

Sheet steel 2.5 mm

Sheet steel 2.5 mm

Sheet steel 2.5 mm

Lateral stay profile

Sheet steel 2.5 mm

Sheet steel 4 mm

Sheet steel 4 mm

Surface

Powder coating
Finely textured surface for indoor installation RAL 7032

Standard version

A standard rack is supplied with the


following standard enclosure parts:

Rear panel

Edge-folded, sheet steel 1.5 mm, powder coated

Side panels (for stand-alone


installation only)

Edge-folded, sheet steel 1.5 mm, powder coated

Door

Sheet steel 1.5 mm, powder coated


Front door (right-hand hinges) or double-wing doors with
minimum width = 1000 mm
Espagnolette lock with double-bit key acc. to DIN 43668
Lock insert with 3 mm dia. pin
180 hinges (opening angle on cubicle suites
approx. 130)

Trim strip

Petrol

Roof plate

Plain, steel sheet 1.5 mm, galvanized

Degree of protection

IP40 according to EN 60529

Paint finish

Powder coated, finely textured surface, for indoor installation

Sheet steel 1.5 mm, powder coated


Front door (right-hand hinges) or double-wing doors with
minimum width = 1200 mm
Espagnolette lock with double-bit key acc. to DIN 43668
Lock insert with 3 mm dia. pin
180 hinges (opening angle on cubicle suites
approx. 130)

RAL 70321) (other cubicle colors on request)


1)

The colors RAL 7032 and 7035 are identical in price.

Order designations of the standard versions


8MF5 and 8MF6 cubicles (screwed)

8MF2 cubicles (welded)


8 MF 2 7 7 7 7 7
Height

Width

1800 mm
2000 mm
2200 mm
600 mm
800 mm
900 mm
1000 mm
1200 mm

6
8
9
0
2

Depth

400 mm
600 mm
800 mm

Degree of
protection

IP54

Installation

Stand-alone installation
with two side panels

Suite installation
without side panels

5/4

Siemens LV 50 2012

8 MF 5 7 7 7 7 7
8 MF 6 7 7 7 7 7

8
0
2

4
6
8
5

Height

1800 mm
2000 mm
2200 mm

Width

600 mm
800 mm
900 mm
1200 mm

Depth

400 mm
600 mm
800 mm

Degree of
protection

IP54

Installation

Stand-alone installation
with two side panels

Suite installation
without side panels

8
0
2
6
8
9
2
4
6
8
5

Siemens AG 2012

Preconfigured Cubicles
IP54 Cubicles
8MF2, 8MF5/6 cubicles

Design
8MF2 system cubicles
Features
Cubicle rack comprising two side frame sections and four
lateral stays
Fully welded
Profile of the side frames folded 5 times

Scope of delivery
A standard rack is delivered with the following standard
enclosure parts
Rear panel
Plain roof
Door with espagnolette lock and lock inserts
Side panels (in case of stand-alone installation)
Mounting of the enclosure parts using self-tapping screws;
no additional grounding measures are necessary therefore
Seal

7
3

NSE0_01357

Fitting of devices and internal partitions


1

Internal interfaces for partitions and devices:


Two rows of holes with a diameter of 9.2 mm and spacing of
20 mm

2
Welded rack
5
Door (right-hand hinge) 6
Side panel
7
Roof panel

1
2
3
4

Rear panel
Zierblende
Seal (only for degree
of protection IP54)

Mounting with special bolts and contact washers which comply with the grounding regulations
8MF5 and 8MF6 system cubicles
Features
Cubicle rack comprising two side frame sections and four
lateral stays
Angle-welded side frame
Screwed lateral stays
Profile of the side frames folded 5 times
Type of delivery of the 8MF5: unassembled
Type of delivery of the 8MF6: assembled
Seal
The cubicle is secured to the floor using 4 holes with a
diameter of 14.5 mm in both bottom lateral stays
(see the Configuration CD at the end of the appendix).

7
3
6

NSE0_01371a

2
1
2
3
4

Screwed rack
5
Door (right-hand hinge) 6
Side panel
7
Roof panel

Rear pane
Trim strip
Seal (only for degree
of protection IP54)

Siemens LV 50 2012

5/5

Siemens AG 2012

Preconfigured Cubicles
IP54 Cubicles
8MF2, 8MF5/6 cubicles

Selection and ordering data


8MF2 cubicles (welded)
Height

Width

Depth

DT Stand-alone installation
Order No.

mm

mm

mm

Weight DT Suite installation


per PU
Order No.
approx.
kg

Weight
per PU
approx.
kg

Degree of protection IP54


1800

2000

2200

600

400
600
800

8MF2 864-5E
8MF2 866-5E
8MF2 868-5E

85.000
90.000
100.000

8MF2 864-5R
8MF2 866-5R
8MF2 868-5R

85.000
90.000
100.000

800

400
600
800

8MF2 884-5E
8MF2 886-5E
8MF2 888-5E

95.000
100.000
110.000

8MF2 884-5R
8MF2 886-5R
8MF2 888-5R

95.000
100.000
110.000

900

400
600
800

8MF2 894-5E
8MF2 896-5E
8MF2 898-5E

100.000
110.000
120.000

8MF2 894-5R
8MF2 896-5R
8MF2 898-5R

100.000
110.000
120.000

1000

400
600
800

8MF2 804-5E
8MF2 806-5E
8MF2 808-5E

100.000
110.000
120.000

8MF2 804-5R
8MF2 806-5R
8MF2 808-5R

100.000
110.000
120.000

1200

400
600
800

8MF2 824-5E
8MF2 826-5E
8MF2 828-5E

115.000
125.000
135.000

8MF2 824-5R
8MF2 826-5R
8MF2 828-5R

115.000
125.000
135.000

600

400
600
800

8MF2 064-5E
8MF2 066-5E
8MF2 068-5E

105.000
105.000
120.000

8MF2 064-5R
8MF2 066-5R
8MF2 068-5R

105.000
105.000
120.000

800

400
600
800

8MF2 084-5E
8MF2 086-5E
8MF2 088-5E

110.000
120.000
165.000

8MF2 084-5R
8MF2 086-5R
8MF2 088-5R

110.000
120.000
165.000

900

400
600
800

8MF2 094-5E
8MF2 096-5E
8MF2 098-5E

125.000
135.000
145.000

8MF2 094-5R
8MF2 096-5R
8MF2 098-5R

125.000
135.000
145.000

1000

400
600
800

8MF2 004-5E
8MF2 006-5E
8MF2 008-5E

130.000
145.000
155.000

8MF2 004-5R
8MF2 006-5R
8MF2 008-5R

130.000
145.000
155.000

1200

400
600
800

8MF2 024-5E
8MF2 026-5E
8MF2 028-5E

145.000
155.000
165.000

8MF2 024-5R
8MF2 026-5R
8MF2 028-5R

145.000
155.000
165.000

600

400
600
800

8MF2 264-5E
8MF2 266-5E
8MF2 268-5E

130.000
135.000
145.000

8MF2 264-5R
8MF2 266-5R
8MF2 268-5R

130.000
135.000
145.000

800

400
600
800

8MF2 284-5E
8MF2 286-5E
8MF2 288-5E

135.000
145.000
175.000

8MF2 284-5R
8MF2 286-5R
8MF2 288-5R

135.000
145.000
175.000

900

400
600
800

8MF2 294-5E
8MF2 296-5E
8MF2 298-5E

140.000
165.000
175.000

8MF2 294-5R
8MF2 296-5R
8MF2 298-5R

140.000
165.000
175.000

1000

400
600
800

8MF2 204-5E
8MF2 206-5E
8MF2 208-5E

165.000
175.000
185.000

8MF2 204-5R
8MF2 206-5R
8MF2 208-5R

165.000
175.000
185.000

1200

400
600
800

8MF2 224-5E
8MF2 226-5E
8MF2 228-5E

185.000
195.000
210.000

8MF2 224-5R
8MF2 226-5R
8MF2 228-5R

185.000
195.000
210.000

Note
Package size for cubicles = 1 unit, i. e.
1 unit or a multiple thereof can be ordered.
If a door with left-hand hinges is required, add the suffix "-Z" to
the Order No. and "left-hand hinge" to the text.
Special size available on request.

5/6

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Preconfigured Cubicles
IP54 Cubicles
8MF2, 8MF5/6 cubicles
8MF5 cubicles (screwed, unassembled)
Height

Width

Depth

DT Stand-alone installation
Order No.

mm

mm

mm

Weight DT Suite installation


per PU*)
Order No.
approx.
kg

Weight
per PU*)
approx.
kg

Degree of protection IP54


1800

2000

2200

600

400
600
800

8MF5 864-5E
8MF5 866-5E
8MF5 868-5E

85.000
90.000
100.000

8MF5 864-5R
8MF5 866-5R
8MF5 868-5R

85.000
90.000
100.000

800

400
600
800

8MF5 884-5E
8MF5 886-5E
8MF5 888-5E

95.000
100.000
110.000

8MF5 884-5R
8MF5 886-5R
8MF5 888-5R

95.000
100.000
110.000

900

400
600
800

8MF5 894-5E
8MF5 896-5E
8MF5 898-5E

100.000
110.000
120.000

8MF5 894-5R
8MF5 896-5R
8MF5 898-5R

100.000
110.000
120.000

1200

400
600
800

8MF5 824-5E
8MF5 826-5E
8MF5 828-5E

115.000
125.000
135.000

8MF5 824-5R
8MF5 826-5R
8MF5 828-5R

115.000
125.000
135.000

600

400
600
800

8MF5 064-5E
8MF5 066-5E
8MF5 068-5E

105.000
105.000
120.000

8MF5 064-5R
8MF5 066-5R
8MF5 068-5R

105.000
105.000
120.000

800

400
600
800

8MF5 084-5E
8MF5 086-5E
8MF5 088-5E

110.000
120.000
165.000

8MF5 084-5R
8MF5 086-5R
8MF5 088-5R

110.000
120.000
165.000

900

400
600
800

8MF5 094-5E
8MF5 096-5E
8MF5 098-5E

125.000
135.000
145.000

8MF5 094-5R
8MF5 096-5R
8MF5 098-5R

125.000
135.000
145.000

1200

400
600
800

8MF5 024-5E
8MF5 026-5E
8MF5 028-5E

145.000
155.000
165.000

8MF5 024-5R
8MF5 026-5R
8MF5 028-5R

145.000
155.000
165.000

600

400
600
800

8MF5 264-5E
8MF5 266-5E
8MF5 268-5E

130.000
135.000
145.000

8MF5 264-5R
8MF5 266-5R
8MF5 268-5R

130.000
135.000
145.000

800

400
600
800

8MF5 284-5E
8MF5 286-5E
8MF5 288-5E

135.000
145.000
175.000

8MF5 284-5R
8MF5 286-5R
8MF5 288-5R

135.000
145.000
175.000

900

400
600
800

8MF5 294-5E
8MF5 296-5E
8MF5 298-5E

140.000
165.000
175.000

8MF5 294-5R
8MF5 296-5R
8MF5 298-5R

140.000
165.000
175.000

1200

400
600
800

8MF5 224-5E
8MF5 226-5E
8MF5 228-5E

185.000
195.000
210.000

8MF5 224-5R
8MF5 226-5R
8MF5 228-5R

185.000
195.000
210.000

Note
Package size for cubicles = 1 unit, i. e.
1 unit or a multiple thereof can be ordered.
If a door with left-hand hinges is required, add the suffix "-Z" to
the Order No. and "left-hand hinge" to the text.
Special size available on request.

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

5/7

Siemens AG 2012

Preconfigured Cubicles
IP54 Cubicles
8MF2, 8MF5/6 cubicles
8MF6 cubicles (screwed, assembled)
Height

Width

Depth

DT Stand-alone installation
Order No.

mm

mm

mm

Weight DT Suite installation


per PU*)
Order No.
approx.
kg

Weight
per PU*)
approx.
kg

Degree of protection IP54


1800

2000

5
2200

600

400
600
800

8MF6 864-5E
8MF6 866-5E
8MF6 868-5E

85.000
90.000
100.000

8MF6 864-5R
8MF6 866-5R
8MF6 868-5R

85.000
90.000
100.000

800

400
600
800

8MF6 884-5E
8MF6 886-5E
8MF6 888-5E

95.000
100.000
110.000

8MF6 884-5R
8MF6 886-5R
8MF6 888-5R

95.000
100.000
110.000

900

400
600
800

8MF6 894-5E
8MF6 896-5E
8MF6 898-5E

100.000
110.000
120.000

8MF6 894-5R
8MF6 896-5R
8MF6 898-5R

100.000
110.000
120.000

1200

400
600
800

8MF6 824-5E
8MF6 826-5E
8MF6 828-5E

115.000
125.000
135.000

8MF6 824-5R
8MF6 826-5R
8MF6 828-5R

115.000
125.000
135.000

600

400
600
800

8MF6 064-5E
8MF6 066-5E
8MF6 068-5E

105.000
105.000
120.000

8MF6 064-5R
8MF6 066-5R
8MF6 068-5R

105.000
105.000
120.000

800

400
600
800

8MF6 084-5E
8MF6 086-5E
8MF6 088-5E

110.000
120.000
165.000

8MF6 084-5R
8MF6 086-5R
8MF6 088-5R

110.000
120.000
165.000

900

400
600
800

8MF6 094-5E
8MF6 096-5E
8MF6 098-5E

125.000
135.000
145.000

8MF6 094-5R
8MF6 096-5R
8MF6 098-5R

125.000
135.000
145.000

1200

400
600
800

8MF6 024-5E
8MF6 026-5E
8MF6 028-5E

145.000
155.000
165.000

8MF6 024-5R
8MF6 026-5R
8MF6 028-5R

145.000
155.000
165.000

600

400
600
800

8MF6 264-5E
8MF6 266-5E
8MF6 268-5E

130.000
135.000
145.000

8MF6 264-5R
8MF6 266-5R
8MF6 268-5R

130.000
135.000
145.000

800

400
600
800

8MF6 284-5E
8MF6 286-5E
8MF6 288-5E

135.000
145.000
175.000

8MF6 284-5R
8MF6 286-5R
8MF6 288-5R

135.000
145.000
175.000

900

400
600
800

8MF6 294-5E
8MF6 296-5E
8MF6 298-5E

140.000
165.000
175.000

8MF6 294-5R
8MF6 296-5R
8MF6 298-5R

140.000
165.000
175.000

1200

400
600
800

8MF6 224-5E
8MF6 226-5E
8MF6 228-5E

185.000
195.000
210.000

8MF6 224-5R
8MF6 226-5R
8MF6 228-5R

185.000
195.000
210.000

Note
Package size for cubicles = 1 unit, i. e.
1 unit or a multiple thereof can be ordered.
If a door with left-hand hinges is required, add the suffix "-Z" to
the Order No. and "left-hand hinge" to the text.
Special size available on request.

5/8

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Preconfigured Cubicles
EMC Cubicles
8MF5, 8MF6 cubicles

Overview
Definition of EMC
Directive 2004/108/EC, Article 2, Paragraph 1d:
"Electromagnetic compatibility means the ability of equipment to
function satisfactorily in its electromagnetic environment without
introducing intolerable electromagnetic disturbances to other
equipment in that environment."
To ensure a system's EMC, it is necessary that its devices emit
only limited interference and are at the same time immune as far
as possible to external interference. In other words, the level of
interference emitted by a device must lie below the interference
threshold of any second device installed in the same location,
taking into consideration the influence of the interference
transmission path (keyword: "Interference immunity").
For such evaluations, the whole frequency range from 0 Hz to an
upper limit frequency determined by the device concerned,
which could well lie in the GHz range, must be taken into
account. To be able to meet the overall requirements, it is
imperative that the devices satisfy certain demands, and that
they comply with the defined limit values regarding interference
emission and interference immunity.
Design of an EMC cubicle

The 8MF EMC cubicle is available in the version:


galvanized, with approx. 55 dB attenuation.
How does the PC cubicle differ from a system cubicle?
The following differences can be listed compared to a standard
8MF system cubicle:
Paint finish only on the outer surfaces of doors and rear/side
panels
Conductive seals pre-mounted for doors and rear/side panels
Additional standard base plate
The whole cubicle frame and all enclosure parts are galvanized,
which serves to extend the shield attenuation measures to the
cubicle installations.
The visible (exterior) areas of the cubicle enclosure are painted.
Doors, roof plate, side panel and rear panel are provided with
special RF seals and each screwed to the cubicle rack at several
points. Special EMC cubicles can be supplied in all standard
dimensions, but only up to a width of 900 mm and only with
single-wing doors. The cubicle enclosure parts can also be
supplied with ventilation slots and integrated RF seals.
The shield attenuation of the 8MF EMC cubicles is approx. 60 dB
over a frequency range from 10 kHz to 1 GHz (corresponds to
an attenuation factor of 1000). By comparison, standard 8MF
cubicles provide a shield attenuation of up to 20 dB.

Electromagnetic compatibility (EMC)


EMC measures are becoming more and more important both for
individual devices and complete systems. The reasons are in
particular:
System processing speeds are becoming ever faster
Systems are becoming more extensive
Many different device types may be encountered in a single
system
Various power levels may be present in a single system
More and more external interference sources

Siemens LV 50 2012

5/9

Siemens AG 2012

Preconfigured Cubicles
EMC Cubicles
8MF5, 8MF6 cubicles
Order designation
8 MF 5 7 7 7 7 7 7
8 MF 6 7 7 7 7 7 7
Height

Width

Depth

1800 mm

2000 mm

2200 mm

600 mm

800 mm

900 mm

400 mm

600 mm

800 mm

Degree of
protection

IP40

Installation

Stand-alone installation

4
E

With two side panels


Surface

Galvanized

Selection and ordering data


Height

Width

Depth

DT 8MF5
Order No.

Weight DT 8MF6
per PU
approx.
Order No.

mm

mm

mm

1800

600

400
600
800

8MF5 864-4ES
8MF5 866-4ES
8MF5 868-4ES

90.000
100.000
110.000

8MF6 864-4ES
8MF6 866-4ES
8MF6 868-4ES

90.000
100.000
110.000

800

400
600

8MF5 884-4ES
8MF5 886-4ES

100.000
110.000

8MF6 884-4ES
8MF6 886-4ES

100.000
110.000

900

400
600

8MF5 894-4ES
8MF5 896-4ES

110.000
120.000

8MF6 894-4ES
8MF6 896-4ES

110.000
120.000

600

400
600
800

8MF5 064-4ES
8MF5 066-4ES
8MF5 068-4ES

115.000
125.000
135.000

8MF6 064-4ES
8MF6 066-4ES
8MF6 068-4ES

115.000
125.000
135.000

800

400
600

8MF5 084-4ES
8MF5 086-4ES

120.000
130.000

8MF6 084-4ES
8MF6 086-4ES

120.000
130.000

900

400
600

8MF5 094-4ES
8MF5 096-4ES

135.000
145.000

8MF6 094-4ES
8MF6 096-4ES

135.000
145.000

600

400
600
800

8MF5 264-4ES
8MF5 266-4ES
8MF5 268-4ES

140.000
145.000
155.000

8MF6 264-4ES
8MF6 266-4ES
8MF6 268-4ES

140.000
145.000
155.000

800

400
600

8MF5 284-4ES
8MF5 286-4ES

145.000
155.000

8MF6 284-4ES
8MF6 286-4ES

145.000
155.000

900

400
600

8MF5 294-4ES
8MF5 296-4ES

150.000
175.000

8MF6 294-4ES
8MF6 296-4ES

150.000
175.000

2000

2200

kg

Weight
per PU
approx.
kg

Note
Package size for cubicles = 1 unit, i. e.
1 unit or a multiple thereof can be ordered.
If a door with left-hand hinges is required, add the suffix "-Z" to
the Order No. and "left-hand hinge" to the text.
Special size available on request.

5/10

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Preconfigured Cubicles
EMC Cubicles
8MF5, 8MF6 cubicles

Configuration
Principles of EMC

Installation notes for EMC-compliant configuration

Electromagnetic compatibility is achieved where the functioning


of potentially susceptible devices is not influenced by the
existing interference sources.

Applications in industrial environments

If two devices are not electromagnetically compatible, it is


possible to either reduce the interference emission of the
interference source or increase the immunity of the potentially
susceptible device.
Interference emission and interference immunity
EMC is dependent on two properties of the devices involved:
interference emission and
immunity to interference
A device may be both an interference source and a potentially
susceptible device. The power unit of a converter, for example,
is to be seen as an interference source, whereas the sensor, the
control section and the evaluation circuit represent a potentially
susceptible device.
Interference immunity describes the behavior of a device when
subjected to electromagnetic interference. The demands and
evaluation criteria for the behavior of devices in industrial
environments are laid down in the standard EN 50082-2.
Limit values
Compliance with EN 55011 is often demanded for interference
emissions in industrial and residential environments.
The limit values "A1" and "B1" are defined for the RF interference
voltage in the range between 150 kHz and 30 MHz, and for RF
interference radiation between 30 MHz and 2 GHz.
To comply with limit value class A1 as defined by EN 55011, for
example, the RF interference voltage at the system terminal must
not exceed max. 79 dB (V) between 150 and 500 kHz and max.
73 dB (V) between 500 kHz and 30 MHz (9 mV and 4.5 mV).
Example case: As the SIMOREG K converters are used in
industrial environments, the limit value "A1" applies. For
compliance with the limit value "A1", SIMOREG K devices must
be provided with external interference suppressor filters.

In industrial applications, the EMC of the devices should be


based on a balanced mix of interference emission and
interference immunity. Complex filter measures are necessary to
reduce their interference emissions. Less expenditure is
necessary to raise the interference immunity of low-power
devices.
In industrial environments, therefore, measures to raise
interference immunity are often more economical than measures
to reduce interference emissions. In industrial environments, the
interference immunity of devices must be very high, whereas the
requirements regarding interference emissions are more lenient.
According to product standard EN 61800, a solution which is
adapted to the actually existing environment must be specified.
If the drive is part of a system, it is not initially required to meet
specific interference emission demands. The EMC legislation
specifies, however, that the system as a whole must be
electromagnetically compatible with its environment.
If all control components of a system (e. g. automation devices)
possess industry-standard interference immunity, it is not
imperative for each individual drive to observe the limit value
"A1".
Converters are components for electric drives, just like
contactors and switches. Qualified personnel are required to
integrate them into a drive system, which comprises at least the
converter, motor cables and a motor. Usually, commutating
reactors and fuses are also necessary. Proper installation also
determines whether or not limit values are observed.
To limit interference emissions sufficiently to comply with the limit
value "A1", the converter must be configured with at least the
corresponding suppressor filter and commutating reactor.
Without interference suppressor filter, the interference emission
of a SIMOREG K converter exceeds the limit value "A1" defined
in EN 55011.
The least expensive suppression measure is spatial separation
of the interference sources and the potentially susceptible
devices, provided this is already taken into account during the
planning of the machine or equipment. First of all, it is necessary
to classify each device used as either an interference source or
a potentially susceptible device. In the cubicle, the different
types of components (interference sources and potentially
susceptible devices) are kept apart from each other, where
necessary by means of partition plates or installation in metal
enclosures.
Non-grounded systems
In certain branches of industry, non-grounded systems
(IT systems) are used to raise the availability of the equipment.
In case of a ground fault, no residual current flows and
production is able to continue. In conjunction with interference
suppressor filters, however, a ground fault leads to a residual
current which could shut down the drives or even maybe destroy
the suppressor filter. The product standard thus defines no limit
values for such systems. From an economic point of view,
necessary interference suppression should be implemented on
the grounded primary side of the feeding transformer.

Siemens LV 50 2012

5/11

Siemens AG 2012

Preconfigured Cubicles
Earthquake-Resistant Cubicles
8MF6 cubicles

Overview
8MF6 system cubicle in an earthquake-resistant version
The demand for system cubicles in regions with a higher risk of
earthquakes continues to rise. For this reason, we have been the
first system cubicle manufacturer to develop a generally
earthquake- resistant system cubicle. The design has been
subjected to thorough vibration testing (simulated earthquakes).
When developing this system cubicle, we were able to make use
of the considerable know-how already present in the company in
the field of earthquake-resistant switchgear (SIVACON sicube).
This enabled us to derive the necessary measures for
adaptation of the 8MF6 cubicle.
This cubicle is a certified earthquake-resistant system cubicle.
An appropriate weight distribution and center of gravity are
prescribed by the certification and serve as a guideline for
interior installations.
The devices and components installed by the customer must
also satisfy the relevant demands. Installations can be mounted
in the system cubicle in three planes (rear, center and front), the
front plane being intended for 19" expansions.
By eliminating cost-intensive cross-bonding, we have not only
achieved a favorable price, but are also able to perform
deliveries at short notice (approx. 4 weeks after receipt of an
order).

NSE0_01372

5/12

Siemens LV 50 2012

Side supporting bar

Corner brace, bottom

Stiffening bar, top

4
5

Corner brace, top

Stiffening bar, bottom

Base plate with multiple


subdivisions

Strengthening plate

Siemens AG 2012

Preconfigured Cubicles
Earthquake-Resistant Cubicles
8MF6 cubicles
Scope of delivery
8MF6

Earthquake-resistant version
Cubicle racks

Screwed (assembled), zinkcor coated and powder coated

Side frame profile

Sheet steel 2.5 mm

Lateral stay profile

Sheet steel 4 mm,


corner bracing bracket (top and bottom)
Base plates in the lateral stays (top, bottom)

Bracing stay

Screwed to rack at front top and bottom

Enclosure parts
Rear panel or fixed masking frame

Edge-folded, sheet steel 1.5 mm, powder coated

Side panels

One partition panel each on right and left,


sheet steel 2.5 mm, galvanized,
screwed every 200 mm

Support columns

One support column each in the right and left side frame, screwed to the partition panel

Mounting plates

Sheet steel 2.5 mm, galvanized, with bracing profiles at rear


5 units at height of 400 mm or
2 units at height of 1000 mm

Door

Trim strip

Petrol

Roof plate

Plain, steel sheet 1.5 mm, galvanized, screwed every 200 mm

Base plate

With multiple divisions and foam rubber profile

Paint finish

Powder coated, finely textured surface,


for indoor installation

Sheet steel 1.5 mm, powder coated


Front door (right-hand hinges) or double-wing doors with width = 900 mm
Espagnolette lock with double-bit key according to DIN 43668
Lock insert with 3 mm dia. pin
180 hinges (opening angle on cubicle suites approx. 130)

Cubicle color

RAL 70321) (other cubicle colors on request)

Rack color

RAL 7032

Degree of protection

IP40/IP54 according to EN 60529

1)

The colors RAL 7032 and 7035 according to the Siemens standard are
identical in price.

Order designations
8 MF 6 7 7 7 7 7 7
Height

2200 mm

Width

600 mm
900 mm

2
6
9

Depth

600 mm

Degree of
protection

IP40
IP541)

Installation

Earthquake-resistant
installation
(without side panels)

1)

6
4
5
K E

Possible only with side panels.

Selection and ordering data


Height

Width

Depth

mm

mm

mm

DT Order No.

Weight
per PU*)
approx.
kg

Degree of protection IP40


2200

600

600

8MF6 266-4KE

155.000

900

600

8MF6 296-4KE

185.000

Degree of protection IP54


2200

600

600

8MF6 266-5KE

155.000

900

600

8MF6 296-5KE

185.000

Note
Package size for cubicles = 1 unit, i. e.
1 unit or a multiple thereof can be ordered.
If a door with left-hand hinges is required, add the suffix "-Z" to
the Order No. and "left-hand hinge" to the text.
Special size on request

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

5/13

Siemens AG 2012

Preconfigured Cubicles
Notes

5/14

Siemens LV 50 2012

Siemens AG 2012

Special Cubicles
6/2

General information

6/2

Special applications of cubicles


for protection and control systems

6/3

Cubicles for transportation


systems

6/5

Cubicles for control systems

6/6

PC Cubicles
8MF2 cubicles
Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 50 2012

Siemens AG 2012

Special Cubicles
General information

Overview
We are able to offer our customers individual system cubicle
solutions. In this way, customers are able to concentrate on their
own expertise and can be confident of lasting success on the
basis of standardized system solutions.
Customer-specific
Just-in-time delivery of our customized system cubicles straight
to the assembly line helps our customers in designing their
products.
Flexible delivery
We supply system cubicles at all integration levels:
in parts
as screwed or welded unequipped distribution boards
mechanically prepared
pre-wired
Global availability
We possess our own production facilities and cooperate with
partner manufacturers all over the world, enabling us to satisfy
the worldwide demand of global players.

6
Special applications of cubicles
for protection and control systems

Overview
Protection cubicles (LSA)
The LSA cubicle is intended specifically for operation in
substation control and protection systems. It can be prepared
with a 19" swing frame, power supply unit (device panel
alongside the swing frame), cover plates, cable brackets and
rear mounting plate.
Configurations with cable ducts and standard mounting rails can
also be supplied on request.

6/2

Siemens LV 50 2012

Siemens AG 2012

Special Cubicles
Cubicles for transportation systems

Overview
8MF cubicles in practical applications
CP2000

Project-specific 8MF cubicles were developed and


mechanically prepared to meet the requirements of Siemens
Transportation Systems, one of the leading partners of
international railway operators.
The 8MF cubicle offers convincing security, stability and quality,
satisfying all the enhanced demands for railway applications.
It has thus been the cubicle of choice for the projects DESIRO
Slovenia, CP2000 Portugal, DESIRO South-West Train Great
Britain and AVE Spain.
Project CP2000
For the CP2000 project, the 8MF rack profile was welded in
accordance with the SGK 2.2 standard (see illustration on the
left). The mechanical interior installation comprises:
19" expansions
Device holders
Cable ducts
Flexible cable conduits
Standard mounting rails
Air-conditioning with heat exchangers

6
8MF rack profile
welded in accordance with
the SGK 2.2
welding standard

Detail showing
cable ducts and
conduits in an
8MF cubicle with
19" expansion

Mechanical interior installation with 19"


expansion, device holders, cable ducts, flexible
cable conduits, standard mounting rails and
air-conditioning with heat exchangers

Siemens LV 50 2012

6/3

Siemens AG 2012

Special Cubicles
Cubicles for transportation systems
Project AVE
The high-speed trains from Siemens set new standards in
high-speed rail travel. For this project, a specific, mechanically
prepared cubicle was developed on the basis of our
8MF cubicles.
Features to be emphasized are the unconventional cubicle form
and the sophisticated surface treatment of the individual
components.
Here, too, our design department was able to contribute
valuable know-how to promote an optimum product
development.

8MF system cubicle for AVE Spain with special swing


frame, device holders, cable ducts and standard
mounting rails

8MF system cubicle rack with


side installation plates and
strain relief

8MF rack profile acc. to


the SGK 2.3 welding
standard

6/4

Siemens LV 50 2012

Siemens AG 2012

Special Cubicles
Cubicles for control systems

Overview
System cubicle suite with cooling units also in redundant configuration
8MF6 cubicles are able to accommodate compact, highperformance heat exchanger components as single-circuit or
multiple-circuit cooling systems with cooling capacities up to
100 kW.

The illustration below shows a system for power stations with a


cooling capacity of 20 kW. The heat exchanger is installed in an
8MF cubicle. A compartment is incorporated at the head of the
heat exchanger.

Expansion and control system components have been


developed on the basis of technical specifications and in
cooperation with renowned partners of Siemens AG.

System for power stations with a cooling capacity of 20 kW

Compartment
at the head
of the heat
exchanger

Heat exchanger
installed in
an 8MF cubicle

Siemens LV 50 2012

6/5

Siemens AG 2012

Special Cubicles
PC Cubicles
8MF2 cubicles

Overview
How does the PC cubicle differ from a system cubicle?
The standard door is replaced by:
An upper compartment door
- Two espagnolette locks
- Monitor cutout with inspection pane
- Perforated shelf
- At bottom, perforated shelf for the computer
A hinged flap (center)
- Height approx. 150 mm with 90o stay,
plastic handle (black)
- Behind, a telescopic shelf for a keyboard
- Pull-out side extension for a mousepad
A lower compartment door
- Two espagnolette locks
- Telescopic shelf for a printer
Order designations
A variant of the 8MF system cubicles can also be ordered as a
PC cubicle. The PC cubicle is a robust construction and is thus
suitable for use in industrial environments.
All benefits of the system cubicles, such as self-tapping screw
terminals, protective conductor concept and high cubicle
stability, are to be found also in the PC cubicle.

8 MF 2 7 7 7 7 7 7
Height

1800 mm

2000 mm

2200 mm

Width

600 mm

Depth

600 mm

800 mm

Degree of
protection

IP40

Installation

Stand-alone installation

4
E

With two side panels


Version

PC cubicles

Ordering
Please inquire for prices and delivery times.
Special sizes are also available on request.

6/6

Siemens LV 50 2012

Siemens AG 2012

System Lighting
7/2

Compact, dual, slimline lights

Technical information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 50 2012

Siemens AG 2012

System Lighting
Compact, dual, slimline lights

Overview
Plug-on mounts
If a cubicle light is provided with a plug-on mount, it remains
immune to vibration and can be removed at any later time
without tools.
If fitted between two plug-on mounts, the cubicle light is fixed
statically to the cubicle. The cubicle light can only be fitted to the
cubicle by using plug-on mounts.

Slimline SL 025 light with motion detector

Cubicle lighting
The cubicle light is specifically suitable for operation in
switchgear and controlgear cubicles.
In the case of lights with a SCHUKO socket outlet, the outlet is
incorporated with an on/off switch or motion detector in the
plastic enclosure.
The flat SL 025 slimline light with motion detector or on/off switch
is ideal for operation in cubicles and enclosures with a high
density of built-in electrical/electronic components.
All lights are fitted with environmentally-friendly energy-saving
lamps.

Rating of energy-saving lamps Rating of conventional incandescent


lamps
9W

60 W

11 W

75 W

20 W

100 W

Spare lamp: Osram SPD1411-2B (100 W)

7/2

Siemens LV 50 2012

Siemens AG 2012

System Lighting
Compact, dual, slimline lights

Selection and ordering data


Version

DT Order No.

PU
(UNIT,
SET, M)

PS*/
PU

Weight
per PU
approx.
kg

Cubicle lighting
Compact lights
(355 x 65 x 70 mm)

SE0_01334

KL 025
230 V, 50 Hz, 11 W (Germany)

8MF4 900

1 unit

2.230

120 V, 60 Hz, 9 W (Germany)

8MF4 901

1 unit

1.115

240 V, 50 Hz, 11 W

8MF4 900-1A

1 unit

1.000

8MF4 904

1 unit

1.000

8MF4 900-1B

1 unit

1.000

8MF4 900-1BB

1 unit

1.100

8MF4 908

1 unit

0.100

220 ... 240 V, 50-60 Hz, 20 W,


with motion detector

8MF4 902

1 unit

0.600

220 ... 240 V, 50-60 Hz, 20 W,


with on/off switch

8MF4 905

1 unit

0.600

220 ... 240 V, 50-60 Hz, 20 W,


as hand-held lamp

8MF4 906

1 unit

0.600

KL 025 with cover


230 V, 50 Hz, 11 W
KL 025 with 3 m cable
230 V, 50 Hz, 11 W
KL 025 with 3 m cable (orange-colored)
230 V, 50 Hz, 11 W
Spare parts for KL 025 compact lights
Covers

Dual lights
(396 x 67 x 100 mm)
DL 026

Slimline lights
(345 x 91 x 40 mm)
SL 025, 230 V, 50/60 Hz, 11 W
with pushbutton switch (On/Off)

8MF5 900-1A

With socket outlet D, without magnet

8MF5 900-1A

1 unit

0.400

With socket outlet D,


with magnet (approx. 50 N)

8MF5 900

1 unit

0.600

With socket outlet D,


with magnet (approx. 30 N)

8MF5 900-1C

1 unit

0.500

Without socket outlet, without magnet

8MF5 900-2A

1 unit

0.400

Without socket outlet D,


with magnet (approx. 50 N)

8MF5 900-1B

1 unit

0.600

Without socket outlet D,


with magnet (approx. 30 N)

8MF5 900-2B

1 unit

0.500

SL 025, 230 V, 50/60 Hz, 11 W


with motion detector

8MF5 910-1A

With socket outlet D, without magnet

8MF5 910-1A

1 unit

0.400

With socket outlet D,


with magnet (approx. 50 N)

8MF5 910

1 unit

0.600

With socket outlet D,


with magnet (approx. 30 N)

8MF5 910-1C

1 unit

0.500

Without socket outlet, without magnet

8MF5 910-2A

1 unit

0.400

Without socket outlet D,


with magnet (approx. 50 N)

8MF5 910-1B

1 unit

0.600

Without socket outlet D,


with magnet (approx. 30 N)

8MF5 910-2B

1 unit

0.500

Without socket outlet, without magnet

8MF5 900-3A

1 unit

0.400

Without socket outlet,


with magnet (approx. 30 N)

8MF5 900-3B

1 unit

0.500

Without socket outlet, without magnet

8MF5 910-3A

1 unit

0.400

Without socket outlet,


with magnet approx. 30 N

8MF5 910-3B

1 unit

0.500

SL 025, 24 ... 48 V DC, 11 W,


with pushbutton switch (On/Off)

SL 025, 24 ... 48 V DC, 11 W,


with motion detector

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

7/3

Siemens AG 2012

System Lighting
Compact, dual, slimline lights

Accessories
Version

DT Order No.

PU
(UNIT,
SET, M)

PS*/
PU

Weight
per PU
approx.
kg

Plug-on mounts
Plug-on mount
8MF4 903

1 unit

0.100

8MF4 890

1 unit

1.200

NSE0_01335

For fitting the cubicle lighting

NSE0_01380

Fastening plates
Lamp plate
For 8MF cubicle

Further information
Further information see Industry Mall under
"Building Technologies":
"Low-Voltage Power Distribution and Electrical Installation
Technology"
"SIVACON Power Distribution Boards and Busbar Trunking
Systems"
"System Cubicles, System Lighting and
System Air-Conditioning"
"SIVACON 8MF System Lighting"

7/4

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

System Air-Conditioning
8/2

Introduction

8/4

Filter fans

8/7

Air conditioners/cooling devices

8/8

Heat exchangers

8/9

Heater units

8/10

Fan heaters

8/12

Thermostats, hygrostats,
hygrotherms, switching modules
Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 50 2012

Siemens AG 2012

System Air-Conditioning
Introduction

Overview
Control supply voltage or voltage for switching capacity
24/48 V DC

115 V AC

230 V AC

400/440 V AC

With or without additional EMC protection

--

Cooling capacity 8 W/K ... 282 W/K

--

Air rate 25 m3/h ... 845 m3/h

--

Size 92 92 mm to 292 mm 292 mm

--

Color RAL 7035 or RAL 7032

--

Cooling capacity 113 W/K ... 242 W/K

--

--

Air rate 350 m3/h ... 690 m3/h

--

--

Size 430 mm 430 mm to 470 mm 470 mm

--

--

Color RAL 7035 or RAL 7032

--

--

--

--

--

--

--

--

--

--

--

100 W ... 1200 W

--

Setting ranges 0 ... +60 C, +32 ... +140 F

--

Setting ranges -10... +80 C

--

--

Switching capacities up to 16 A

--

Hygrostats, changeover contacts

--

40 ... 95 % relative air humidity

--

--

Setting ranges 0 ... 60 C, +32 ... +140 F

--

--

50 ... 90 % relative air humidity

--

--

Switching capacities 6 (1) A ... 8 (1.6) A

--

Switching modules 16 A

--

--

--

8MR system air-conditioning


Filter fans
Standard filter fans, IP54 or IP55

Roof filter fans, IP44

Air conditioners/cooling devices


For door and side mounting (recessed)
380 ... 5800 W
For roof mounting
410 ... 3850 W
Heat exchangers
Standard
Air/air (at T = 20 K)
For side and door mounting
700 ... 1900 W
Heater units optionally without or with thermostat
10 W ... 150 W
Fan heaters optionally without or with thermostat

Thermostats, hygrostats, hygrotherms, switching modules


Thermostats, optionally NC, NO, CO contacts

Hygrotherms, optionally NC, NO, CO contacts

Available or possible
-- Not available or not possible
On request
The figures in brackets indicate inductive switching capacities.

8/2

Siemens LV 50 2012

Siemens AG 2012

System Air-Conditioning
Introduction

Benefits
Installing air-conditioning equipment in SIVACON sicube cubicle
systems ensures high fault tolerance for switchgear and controlgear assemblies and consequently a high level of availability of
machines and plants.

Application
In control cubicles, depending on the ambient conditions
(e. g. heat, cold, air humidity etc.), there may be a tendency to
overheat or for mold to form. In such cases the cubicles should
be air-conditioned. The following air-conditioning equipment is
available for this purpose:
Filter fans
Air conditioners/cooling devices
Heat exchangers, air/air
Heaters/thermostats
When selecting individual air-conditioning components, the
ambient temperature, the power losses of the installed devices,
the maximum permissible device temperature and the heat
dissipation capacity of the cubicle used are the factors to be
considered. In addition, it is necessary to take into account the
required degree of protection.

Optimum, extended
air duct for the system
air-conditioning

35 C
Hot air from the
equipment and
busbars

55 C

Cubicle

Cold air
recirculation

25 C

NSE0_01390a

System air-conditioning optimum air guidance

Further information
Further information see Industry Mall under
"Building Technologies":
"Low-Voltage Power Distribution and Electrical Installation
Technology"
"SIVACON Power Distribution Boards and Busbar Trunking
Systems"
"System Cubicles, System Lighting and
System Air-Conditioning"
"SIVACON 8MR System Air-Conditioning"

Siemens LV 50 2012

8/3

Siemens AG 2012

System Air-Conditioning
Filter fans

Overview
Filter fans are the most cost-effective method - after heat
dissipation through the surface of a control cubicle and/or
ventilation openings in the enclosure parts of the control
cubicles - for dissipating heat from control cubicles.

Filter fan versions


The following filter fans are available on request:
Standard filter fan IP54, color RAL 7035/7032
Standard filter fan IP55, color RAL 7035/7032
Standard filter fan EMC, color RAL 7035/7032, IP54
Standard filter fan EMC, color RAL 7035/7032, IP55

However, this can only achieve a control cubicle temperature


which lies above the ambient temperature.
Standard filter fans optionally in EMC version

Note:

When filter fans are used for air-conditioning, the cubicle must
have openings which allow electromagnetic radiation to pass in
and out unobstructed. Filter fans in EMC version offer additional
protection when higher requirements are imposed on electromagnetic compatibility.

For all standard filter fans the useful cooling capacity and air rate
are reduced by an average of approx. 30 % in combinations of
filter fan / outlet filter / filter mat, and for roof filter fans by
approx. 40 %.

Selection and ordering data


Filter fans
Degree Size
of protection

Air current,
free blowing
at 50 Hz

Cutout

Voltage

Input
Color
rating
at 50 Hz

m3/h

mm

RAL

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

Filter fans
50/60 Hz except 8MR6 402-2LV41
IP54

25

92 92

115 AC
230 AC
230 AC

12
12
12

7035
7032
7035

8MR6 411-5LV10
8MR6 423-2LV10
8MR6 423-5LV10

1
1
1

1 unit
1 unit
1 unit

0.330
0.330
0.330

63

125 125

115 AC
230 AC
230 AC

20
20
20

7035
7032
7035

8MR6 411-5LV25
8MR6 423-2LV25
8MR6 423-5LV25

1
1
1

1 unit
1 unit
1 unit

0.800
0.800
0.800

115

177 177

115 AC
230 AC

20
20

7035
7035

8MR6 411-5LV30
8MR6 423-5LV30

160

223 223

115 AC
230 AC
230 AC

18
18
18

7035
7032
7035

8MR6 411-5LV45
8MR6 423-2LV45
8MR6 423-5LV45

1
1
1

1 unit
1 unit
1 unit

1.030
1.030
1.400

1
1

1 unit
1 unit

1.400
1.400

8MR6 411-5LV10

250

223 223

24 DC
115 AC
230 AC
230 AC

16
43
45
45

7032
7035
7032
7035

8MR6 402-2LV41
8MR6 411-5LV41
8MR6 423-2LV41
8MR6 423-5LV41

1
1
1
1

1 unit
1 unit
1 unit
1 unit

1.840
1.840
1.840
1.840

580

292 292

115 AC
230 AC
230 AC

64
64
64

7035
7032
7035

8MR6 411-5LV60
8MR6 423-2LV60
8MR6 423-5LV60

1
1
1

1 unit
1 unit
1 unit

3.400
1.840
3.400

930

292 292

115 AC
230 AC

115
135

7035
7035

8MR6 411-5LV80
8MR6 423-5LV80

1
1

1 unit
1 unit

4.600
4.600

63

125 125

115 AC
230 AC

20
20

7035
7035

8MR6 511-5LV25
8MR6 523-5LV25

1
1

1 unit
1 unit

0.800
0.800

115

177 177

115 AC
230 AC

20
20

7035
7035

8MR6 511-5LV30
8MR6 523-5LV30

1
1

1 unit
1 unit

1.030
1.030

160

223 223

115 AC
230 AC

18
18

7035
7035

8MR6 511-5LV45
8MR6 523-5LV45

1
1

1 unit
1 unit

1.400
1.400

250

223 223

115 AC
230 AC

43
45

7035
7035

8MR6 511-5LV41
8MR6 423-5LV41

1
1

1 unit
1 unit

1.840
1.840

580

292 292

115 AC
230 AC

64
64

7035
7035

8MR6 511-5LV60
8MR6 523-5LV60

1
1

1 unit
1 unit

1.840
1.840

930

292 292

115 AC
230 AC

115
135

7035
7035

8MR6 511-5LV80
8MR6 523-5LV80

1
1

1 unit
1 unit

4.600
4.600

8
IP55

8MR6 511-5LV10

8/4

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

System Air-Conditioning
Filter fans
Degree Size
of protection

Air current,
free blowing
at 50 Hz

Cutout

Voltage

Input
Color
rating
at 50 Hz

m3/h

mm

RAL

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

EMC filter fans IP54


IP54

115

177 177

115 AC
230 AC

20
20

7035
7035

8MR6 411-6LV30
8MR6 423-6LV30

1
1

1 unit
1 unit

1.030
1.030

160

223 223

115 AC
230 AC

18
18

7035
7035

8MR6 411-6LV45
8MR6 423-6LV45

1
1

1 unit
1 unit

1.400
1.400

250

223 223

115 AC
230 AC

43
45

7035
7035

8MR6 411-6LV41
8MR6 423-6LV41

1
1

1 unit
1 unit

1.840
1.840

8MR6 411-6LV30
EMC filter fans IP55
IP55

115

177 177

115 AC
230 AC

20
20

7035
7035

8MR6 511-6LV30
8MR6 523-6LV30

1
1

1 unit
1 unit

1.030
1.030

160

223 223

115 AC
230 AC

18
18

7035
7035

8MR6 511-6LV45
8MR6 523-6LV45

1
1

1 unit
1 unit

1.400
1.400

250

223 223

115 AC
230 AC

43
45

7035
7035

8MR6 511-6LV41
8MR6 523-6LV41

1
1

1 unit
1 unit

1.840
1.840

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.

8MR6 511-6LV30

Outlet filters
Size

Dimensions

Color

Cutout

External
dimensions
WH

Overall
depth

Cover
grille
height

mm

mm

mm

mm

RAL

DT Order No.

kg

Outlet filters IP54

8MR6 400-5GV67

92 92

105 105

12

4.5

7032
7035

8MR6 400-2GV10
8MR6 400-5GV10

1
1

1 unit
1 unit

0.060
0.060

125 125

148 148

23

5.5

7032
7035

8MR6 400-2GV25
8MR6 400-5GV25

1
1

1 unit
1 unit

0.170
0.170

177 177

204 204

26

7035

8MR6 400-5GV30

1 unit

0.350

223 223

250 250

32

7032
7035

8MR6 400-2GV45
8MR6 400-5GV45

1
1

1 unit
1 unit

0.500
0.500

292 292

323 323

33

6.5

7032
7035

8MR6 400-2GV67
8MR6 400-5GV67

1
1

1 unit
1 unit

0.800
0.800

Outlet filters IP55


2

125 125

148 148

23

5.5

7035

8MR6 500-5GV25

1 unit

0.170

177 177

204 204

26

7035

8MR6 500-5GV30

1 unit

0.350

223 223

250 250

32

7035

8MR6 500-5GV45

1 unit

0.500

292 292

323 323

33

6.5

7035

8MR6 500-5GV67

1 unit

0.800

8MR6 500-5GV67
EMC outlet filters IP54
3

177 177

204 204

26

7035

8MR6 400-6GV30

1 unit

0.350

223 223

250 250

32

7035

8MR6 400-6GV45

1 unit

0.500

EMC outlet filters IP55


3

177 177

204 204

26

7035

8MR6 500-6GV30

1 unit

0.350

223 223

250 250

32

7035

8MR6 500-6GV45

1 unit

0.500

8MR6 400-6GV30

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

8/5

Siemens AG 2012

System Air-Conditioning
Filter fans
Filter mats
Size

Dimensions

DT Order No.

PU
(UNIT,
SET, M)

WH

PS*/
P. unit

Weight
per PU
approx.
kg

mm
Filter mats for filter fans or outlet filters for IP54
1

89 89

8MR6 000-0AM10

5 units

0.050

118 118

8MR6 000-0AM25

5 units

0.050

171 171

8MR6 000-0AM30

5 units

0.050

216 216

8MR6 000-0AM45

5 units

0.085

283 283

8MR6 000-0AM67

5 units

0.100

Air current

Dimensions

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.

8MR6 000-0AM10

Roof filter fans


Free blowing Cutout
at 50 Hz

External dimensions
WHD

m3/h

mm

mm

Voltage

Input
rating

DT Order No.

kg

Roof filter fans IP44 for 50/60 Hz, color RAL 7035
405

345 265

420 340 108

115
230

40/45
40/45

8MR6 311-5DL40
8MR6 323-5DL40

1
1

1 unit
1 unit

8.200
8.200

690

345 265

420 340 108

115
230

100/130
100/130

8MR6 311-5DL42
8MR6 323-5DL42

1
1

1 unit
1 unit

8.200
8.200

--

--

8MR6 000-5DE40

1 unit

4.500

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.

1 unit

3.300

8MR6 323-5DL40
Roof outlet filters IP44, color RAL 7035
Without fan

345 265

420 340 83

8MR6 000-5DE40

19" withdrawable fan units

Power

Voltage

45

230

Series

DT Order No.

kg
LE 019

8MR2 190-1A

8MR2 190-1A

8/6

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

System Air-Conditioning
Air conditioners/cooling devices

Overview
Where ambient temperatures are higher than the permissible
device temperatures, air conditioners must be used.
All units operate with CFC-free refrigerants. Air conditioners
dehumidify the air inside the control cubicle.
Cooling devices for door or side mounting and roof mounting
Two separate air circuits ensure that no ambient air enters the
control cubicle. High-performance radial fans provide for good
air circulation in the control cubicle.
Intelligent standard electronics with maximum customer
benefits:
Simple temperature control with an integrated thermostat
Test mode
Temperature limits
Start-up delay
Door contact function
Alarm contact
Local diagnostics
UL-approved
CE-approved
Versions
Air conditioners/cooling devices are available in the following
versions:
For side and door mounting
For roof mounting

8MR6 cooling devices:


door or side mounting top left, roof mounting bottom right

Selection and ordering data


Cooling devices for door or side mounting, degree of protection inside IP54/outside IP34, color RAL 7035
Cooling
capacity

Rated
power

Dimensions
WHD

Air capacity
internal/
external

mm

m3/h

Cooling devices for 230 V, 50/60 Hz

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

1)

380

280

285 460 180

280/280

8MR6 423-5EG04

1 unit

23.000

640

400

360 606 212

330/570

8MR6 423-5EG06

1 unit

27.000

820

440

348 783 215

330/570

8MR6 423-5EG08

1 unit

34.000

10502)

570

348 783 215

570/860

8MR6 423-5SK10

1 unit

43.000

15502)

880

400 950 233

570/1050

8MR6 423-5SK15

1 unit

44.000

20502)

1080

400 1265 236

860/1050

8MR6 423-5SK20

1 unit

66.000

Cooling devices for 400 V, 50/60 Hz1)


8MR6 423-5SK20

2900

1220

500 1270 336

860/1450

8MR6 440-5EG30

1 unit

86.000

1780

1780

500 1270 336

1450/1450

8MR6 440-5EG40

1 unit

88.000

5800

2340

600 2000 380

1450/2900

8MR6 440-5EG60

1 unit 156.000

1)

Surface mounting and full integration possible.

2)

Partial integration possible.

Cooling devices for roof mounting, degree of protection inside IP54/outside IP34, color RAL 7035
Cooling
capacity

Rated
power

Dimensions
WHD

Air capacity
internal/
external

mm

m3/h

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

Cooling devices for 230 V, 50/60 Hz


410

270

259 264 486

235/330

8MR6 423-5DE04

1 unit

24.000

820

510

340 340 600

330/570

8MR6 423-5DE08

1 unit

37.700

1150

550

401 415 567

570/1010

8MR6 423-5DE12

1 unit

46.000

1550

810

401 415 567

860/1820

8MR6 423-5DE15

1 unit

50.000

2050

1190

401 415 567

1050/1820

8MR6 423-5DE20

1 unit

56.000

Cooling devices for 400 V, 50/60 Hz


2900

1210

492 496 797

860/3410

8MR6 440-5DE30

1 unit

88.000

3850

1630

492 496 797

1450/3410

8MR6 440-5DE40

1 unit

90.000

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

8/7

Siemens AG 2012

System Air-Conditioning
Heat exchangers

Overview
Air/air principle
Heat exchangers designed on the air/air principle function with
two completely separate air circuits: an internal and an external
circuit. One fan draws in cool external air. A second fan then
directs the warmed air inside the cubicle past a large-area
finned partition element, which passes the heat to the external
circuit.
Note:
The devices can be surface mounted and fully integrated.

Heat exchanger 80 W/K

Selection and ordering data


Air/air heat exchangers, degree of protection IP54, color RAL 7035
Thermal
power

Rated
power

Dimensions
WHD

Air capacity
internal/
external

W/K

mm

m3/h

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

Heat exchangers for 230 V, 50/60 Hz


36

140

316 771 93

80

240

317 1260 108 1050/1050

570/570

8MR6 423-5ML36

1 unit

7.000

8MR6 423-5ML80

1 unit

17.000

8MR6 423-5ML80

8/8

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

System Air-Conditioning
Heater units

Overview
Control cubicle heater units are used for preventing malfunctions
due to condensation water and corrosion and for controlling
the temperature inside the control cubicle (observance of a
minimum temperature).
The plastic enclosure is designed such that the surface
temperatures on the touchable side areas are kept very low.
The heater units are designed for uninterrupted duty.
All units are also available in UL-approved versions and for
special voltages.

Small semiconductor heater unit, 8MR2 131-0A

Selection and ordering data


Version

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

Heater units
Heater units, UL-approved, with PTC thermistor
110-250 V AC/DC

8MR2 130-1A

15W

8MR2 130-1A

2 units

0.600

30 W

8MR2 130-3A

2 units

0.600

45 W

8MR2 130-4A

1 unit

0.300

60 W

8MR2 130-6A

1 unit

0.400

75 W

8MR2 130-7A

1 unit

0.500

100 W

8MR2 130-0A

1 unit

0.500

150 W

8MR2 130-5A

1 unit

0.700

50 W

8MR2 131-4A

1 unit

0.290

100 W

8MR2 131-0A

1 unit

0.300

150 W

8MR2 131-5A

1 unit

0.440

50 W, 15 C

8MR2 132-1A

1 unit

0.300

50 W, 25 C

8MR2 132-1AB

1 unit

0.300

100 W, 15 C

8MR2 132-0A

1 unit

0.310

100 W, 25 C

8MR2 132-0AB

1 unit

0.310

150 W, 15 C

8MR2 132-5A

1 unit

0.440

150 W, 25 C

8MR2 132-5AB

1 unit

0.440

Semiconductor heater units without thermostat,


degree of protection IP20, UL-approved, compact design
120-250 V AC/DC

8MR2 131-4A
Semiconductor heater units with thermostat,
degree of protection IP20, compact design
120-250 V AC/DC

8MR2 132-1A

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

8/9

Siemens AG 2012

System Air-Conditioning
Fan heaters

Overview
Where higher heating outputs (from 150 W) are required, fan
heaters are used.
The integrated fans provide for better air circulation and hereby
achieve a more uniform air temperature distribution in the control
cubicle.
All units are also available in UL-approved versions and for
special voltages.

Fan heaters with integrated thermostat or hygrostat

Selection and ordering data


Version

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

Fan heaters
Fan heaters in standard version
Without fan, UL-approved
- 230 V AC, 100 W

8MR2 140-0A

1 unit

0.400

- 230 V AC, 150 W

8MR2 140-1A

1 unit

0.400

- 230 V AC, 200 W

8MR2 140-2A

1 unit

0.500

- 230 V AC, 300 W

8MR2 140-3A

1 unit

0.500

- 230 V AC, 400 W

8MR2 140-4A

1 unit

0.500

8MR2 140-0A
With fan, UL-certified
- 230 V AC, 100 W

8MR2 140-0B

1 unit

0.600

- 230 V AC, 150 W

8MR2 140-1B

1 unit

0.600

- 230 V AC, 200 W

8MR2 140-2B

1 unit

0.900

- 230 V AC, 300 W

8MR2 140-3B

1 unit

0.900

- 230 V AC, 400 W

8MR2 140-4B

1 unit

0.900

8MR2 140-0B

Compact fan heaters

With fan, UL-certified


- 230 V AC, 250 W

8MR2 122-4A

1 unit

1.100

- 230 V AC, 400 W

8MR2 122-8A

1 unit

1.400

- 120 V AC, 250 W

8MR2 122-4B

1 unit

1.100

- 120 V AC, 400 W

8MR2 122-8B

1 unit

1.400

- 24 V DC, 250 W

8MR2 122-4AB

1 unit

1.100

- 48 V DC, 250 W

8MR2 122-4AC

1 unit

1.100

8MR2 140-6C

1 unit

0.600

8MR2 140-6D

1 unit

1.000

- Temperature range 0 to 60 C

8MR2 150-0A

1 unit

1.400

- 65 % relative air humidity

8MR2 150-0BA

1 unit

1.400

- Temperature range 0 to 60 C

8MR2 150-0C

1 unit

1.450

- 65 % relative air humidity

8MR2 150-0CA

1 unit

1.450

With fan
8MR2 122-4A

Without fan, UL-approved


- 230 V AC, 600 W
With fan
- 230 V AC, 600 W
Fan heaters with integrated thermostat or hygrostat
230 V AC, 950 W
Fan heaters, UL-approved, for floor mounting
8MR2 150-0A

Fan heaters, UL-approved, for wall mounting

8MR2 150-0C

8/10

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

System Air-Conditioning
Fan heaters
Version

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

Semiconductor fan heaters


Fan heaters
UL-approved
Clip fixing for TH 35 standard mounting rail
- 230 V AC, 350 W, C

8MR2 140-3C

1 unit

1.100

- 230 V AC, 550 W, C

8MR2 140-5C

1 unit

1.100

- 120 V AC, 350 W, F

8MR2 140-3D

1 unit

1.100

- 120 V AC, 550 W, F

8MR2 140-5D

1 unit

1.100

- 230 V AC, 150 W, clip fixing for TH 35 standard mounting rail

8MR2 150-2C

1 unit

0.300

- 230 V AC, 150 W, screw fixing

8MR2 150-2D

1 unit

0.300

With thermostat, 0 to 60 C

8MR2 150-2A

1 unit

1.200

Without thermostat

8MR2 150-2B

1 unit

1.200

With thermostat, 0 to 60 C

8MR2 150-3A

1 unit

1.250

Without thermostat

8MR2 150-3B

1 unit

1.250

With fixing

8MR2 150-2C

PTC fan heaters for floor mounting


230 V AC, 1200 W, screw fixing (M5)

8MR2 150-2A
PTC heater units for wall mounting
UL-approved, 230 V AC, 1200 W, clip fixing for TH 35 standard
mounting rail or screw fixing (M6)

8MR2 150-3A

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

8/11

Siemens AG 2012

System Air-Conditioning
Thermostats, hygrostats, hygrotherms,
switching modules

Overview
Hygrostats
Hygrostats are used to regulate heaters/fan heaters so that the
temperature increase raises the dew point from a critical
humidity of 65 % in cubicles and enclosures with built-in
electrical and electronic components. This prevents
condensation on structural parts and electronic components.
Hygrotherms
Hygrotherms monitor both temperature and relative humidity in
cubicles and enclosures with built-in electrical/electronic
components and switch on a heater or fan upon reaching the
selected values (temperature or relative humidity). This prevents
condensation on structural parts and electronic components.
Switching modules
Switching modules are electronic relays for the switching of
high-power DC devices.
Tamper-proof thermostat, FTO 01 series, NC contact

Thermostats

Thermostats, hygrostats or hygrotherms can be connected to


operate the switching modules.
Note:

Thermostats (as NC, NO or CO contacts) are used to regulate


cooling devices, filter fans and heat exchangers, as well as to
trigger signals in case of excessive temperatures.

The switching capacity values quoted in brackets refer to


inductive loads.

Selection and ordering data


Version

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

Thermostats
Small thermostats
UL-approved, max. switching capacity 250 V AC,
10 A (2 A)
NC contacts
- Temperature range 0 ... 60 C

8MR2 170-2BA

1 unit

0.040

- Temperature range -10 ... 50 C

8MR2 170-1CA

3 units

0.150

- Temperature range +20 ... 80 C

8MR2 170-1DA

3 units

0.150

8MR2 170-1BA

NO contacts
- Temperature range 0 ... +60 C

8MR2 170-2BB

1 unit

0.040

- Temperature range -10 ... +50 C

8MR2 170-1CB

3 units

0.040

- Temperature range +20 ... +80 C

8MR2 170-1DB

3 units

0.040

- Temperature range 15 C / 59 F (5 C / 41 F)

8MR2 171-1BA

1 unit

0.023

- Temperature range 25 C / 77 F (15 C / 59 F)

8MR2 171-2BA

1 unit

0.023

- Temperature range 50 C / 122 F (40 C / 104 F)

8MR2 171-1BB

1 unit

0.023

- Temperature range 60 C / 140 F (50 C / 122 F)

8MR2 171-2BB

1 unit

0.023

8MR2 170-1BB
Tamper-proof thermostats
UL-approved, max. switching capacity 250 V AC, 5 A (1.6 A)
NC contacts

NO contacts
8MR2 171-1BA/2BA

8MR2 171-1BA/2BA

8/12

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

System Air-Conditioning
Thermostats, hygrostats, hygrotherms,
switching modules
Version

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

Mechanical thermostats
UL-approved
Changeover contact +5 ... +60 C,
max. switching capacity 250 V AC, 10 A (4 A)

8MR2 170-1A

2 units

0.100

Changeover contact -20 ... +30 C,


max. switching capacity 250 V AC, 10 A (4 A)

8MR2 170-1B

1 unit

0.100

Electronic thermostats
CO contact, 0 ... +60 C,
max. switching capacity 28 V DC, 16 A

8MR2 170-2A

1 unit

0.080

Twin thermostats
NC and NO contacts, 0 ... +60 C,
max. switching capacity 250 V AC, 10 A (2 A)

8MR2 170-1E

2 units

0.090

NC contact, 15 C/59 F (5 C/41 F) and


NO contact, 50 C/122 F (40 C/104 F)
max. switching capacity 250 V AC, 5 A (1.6 A)

8MR2 172-1A

1 unit

0.040

NC contact, 25 C/77 F (15 C/ 59 F) and


NO contact, 60 C/140 F (50 C/122 F)
max. switching capacity 250 V AC, 5 A (1.6 A)
or 30 W DC

8MR2 172-2A

1 unit

0.040

NO contact, 50 C/122 F (40 C/104 F) and


NO contact, 60 C/140 F (50 C/122 F)
max. switching capacity 250 V AC, 5 A (1.6 A)

8MR2 172-1AB

1 unit

0.040

Mechanical hygrostats
UL-approved
For regulating heaters/fan heaters so that the temperature
increase raises the dew point
CO contact, 230 V AC
35 ... 95 % relative air humidity
Max. switching capacity 250 V AC, 5 A (0.2 A) or 20 W DC
Min. switching capacity 20 V AC/DC, 100 mA

8MR2 170-1C

1 unit

0.060

Electronic hygrostats
CO contact, 230 V AC
40 ... 90 % relative air humidity
Max. switching capacity 240 V AC, 8 A (1.6 A)
For regulating heaters/fan heaters so that the temperature
increase raises the dew point

8MR2 170-1AF

1 unit

0.700

8MR2 171-1A

Twin thermostats (Fix)

8MR2 172-1A

Hygrostats

8MR2 170-1AF

* You can order this quantity or a multiple thereof.

Siemens LV 50 2012

8/13

Siemens AG 2012

System Air-Conditioning
Thermostats, hygrostats, hygrotherms,
switching modules
Version

DT Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

Weight
per PU
approx.
kg

Hygrotherms
Electronic hygrotherms
UL-approved, 50 ... 90 % relative air humidity,
for simultaneously monitoring both temperature and
relative humidity in cubicles and enclosures with
electronic components, CO contacts

8MR2 170-4F

120 V AC, +32 to +140 F,


max. switching capacity of NC contacts: 120 V AC, 6 A (1 A),
max. switching capacity of NO contacts: 120 V AC, 8 A (1.6 A)

8MR2 170-4F

1 unit

0.020

120 V AC, 0 ... +60 C,


max. switching capacity of NC contacts: 120 V AC, 6 A (1 A),
max. switching capacity of NO contacts: 120 V AC, 8 A (1.6 A)

8MR2 170-4H

1 unit

0.020

230 V AC, 0 ... +60 C,


max. switching capacity of NC contacts: 240 V AC, 6 A (1 A),
max. switching capacity of NO contacts: 240 V AC, 8 A (1.6 A)

8MR2 170-4E

1 unit

0.200

24 V DC, 16 A

8MR2 180-1A

1 unit

0.085

48 V DC, 16 A

8MR2 180-1B

1 unit

0.085

Switching modules
Switching modules
Electronic relay for switching high-power DC devices from
thermostats, hygrostats or hygrotherms

Further information
Further information see Industry Mall under
"Building Technologies":
"Low-Voltage Power Distribution and Electrical Installation
Technology"
"SIVACON Power Distribution Boards and Busbar Trunking
Systems"
"System Cubicles, System Lighting and
System Air-Conditioning"
""SIVACON 8MR System Air-Conditioning"

8/14

Siemens LV 50 2012

* You can order this quantity or a multiple thereof.

Siemens AG 2012

Appendix
9/2

Catalog notes

9/3

Ordering notes

9/6

Further documentation

9/7

Standards and approvals

9/12

Siemens contacts

9/13

Online services

9/15

Service & support

9/16

Comprehensive support
from A to Z

9/17

Software licenses

9/19

Subject index

9/21

Order number index


incl. Export markings

9/34

Conditions of sale and delivery

Siemens LV 50 2012

Siemens AG 2012

Appendix
Catalog notes

Overview
Registered trademarks

Technical specifications

All product designations may be registered trademarks or


product names of Siemens AG or supplier companies whose
use by third parties for their own purposes may violate the rights
of the owners.

The technical specifications in this catalog are for general information. The instruction manuals and the operating instructions
on the products must be observed during assembly, operation
and maintenance.

Amendments

Further technical information can be found at


www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQs
- Manuals
- Characteristic curves
- Certificates

All technical data, dimensions and weights are subject to


change without notice unless otherwise specified on the pages
of this catalog.
Dimensions
All dimensions are in mm.
Illustrations
The illustrations are not binding.

Configurators can be found at


www.siemens.com/lowvoltage/configurators
Assembly, operation and maintenance
The instruction manuals and the operating instructions on the
products must be observed during assembly, operation and
maintenance.

9/2

Siemens LV 50 2012

Siemens AG 2012

Appendix
Ordering notes

Logistics
General

Packaging, packing units

With regard to delivery service, communications and


environmental protection, our logistics service ensures "quality
from the moment of ordering right through to delivery". By
designing our infrastructure according to customer
requirements and implementing electronic order processing, we
have successfully optimized our logistics processes.

The packaging in which our equipment is dispatched provides


protection against dust and mechanical damage during transport, thus ensuring that you receive our products in a perfect
condition.

We are proud of our personal consulting service, on-time


deliveries and 1-day transport within Germany.
To this end, we supply the preferred types marked with
} ex works.
We regard the DIN ISO 9001 certification and consistent quality
checks as an integral part of our services.
Electronic order processing is fast, cost-efficient and error-free.
Please contact us if you want to benefit from these advantages.

We select our packaging for maximum environmental


compatibility and reusability (e. g. crumpled paper instead of
polystyrene chips for protection during transport in packages up
to 32 kg) and, in particular, with a view to reducing waste.
With our multi-unit packaging and reusable packaging, we offer
you specific types of packaging that are both kind to the
environment and tailored to your requirements:
Your advantages at a glance:
Lower order costs.
Cost savings through uniform-type packaging: low/no
disposal costs.
Reduced time and cost thanks to short unpacking times.
"Just-in-time" delivery directly to the production line helps
reduce stock: cost savings through reduction of storage area.
Fast assembly thanks to supply in sets.
Standard Euro boxes - corresponding to the Euro pallet
modular system - suitable for most conveyor systems.
Active contribution to environmental protection.
Unless stated otherwise in the "Selection and ordering data" of
this catalog, our products are supplied individually packed.
For small parts/accessories, we offer you economical
packaging units as standard packs containing more than one
item, e. g. 5, 10, 50 or 100 units. It is essential that whole
number multiples of these quantities be ordered to ensure
satisfactory quality of the products and problem-free order
processing.
The products are delivered in a neutral carton. The label
includes warning notices, the CE marking, the open arrow
recycling symbol, and product description information in English
and German. In addition to the Order No. (MLFB) and the
number of items in the packaging, the Instr. Order No. is also
specified for the operating instructions. It can be obtained from
your local Siemens representative (you will find a list of your local
Siemens representatives at ww.siemens.de/automation/partner).
The device Order No. of most devices can also be acquired
through the EAN barcode to simplify ordering and storage
logistics.
The Order Nos. and EAN codes are assigned electronically in
the master data of the products for low-voltage power
distribution and electrical installation.

Siemens LV 50 2012

9/3

Siemens AG 2012

Appendix
Ordering notes

Overview
Special versions
The price list does not include prices for special sizes. For
technical reasons it may not be possible to supply all sizes. If
you require quotations for special sizes of our system cubicles
or complex expansions, please contact us at:
Phone:
+49 (341) 4470-472
+49 (341) 4470-534
+49 (341) 4470-475
+49 (341) 4470-493
E-mail:
sicube.sivacon.ic@siemens.com
Inquiries about standard variants can also be submitted via the
Internet:
www.siemens.com/sivacon
For inquiries about special variants please have the following
information available:
Height x width x depth in mm
Degree of protection
Design of the enclosure
(e. g. front door, ventilation roof, rear panel, 2 side panels,
plinth H = 100 mm ...)
Interior installation
Further requirements
Ordering
Please send your order in writing to your Siemens
representative.
Small orders
When small orders are placed, the costs associated with order
processing are higher than the order value. We recommend
therefore that you combine several small orders. Where this is
not possible, we unfortunately have to charge a processing
supplement of 20.-- to cover our costs for order processing
and invoicing for all orders with a net goods value of less
than 250.--.
Ordering special versions
When ordering products that differ from the standard versions
listed in the catalog, "Z" must be added to the Order No.
indicated and the required features must be specified using
alphanumeric order codes or plain text.

Transport and packaging


The following applies for 8MF cubicle systems within Germany:
We charge 8 % of the order value, but at least 25.--, for transport and packaging.
Packaging and transport are free for an order value of over
5000.-- .
For all other products we invoice transport and packaging
charges as incurred.

9/4

Siemens LV 50 2012

Siemens AG 2012

Appendix
Ordering notes
Explanations on the Selection and Ordering Data
Delivery time class (DT)
Preferred types are device types that are available immediately from stock, i. e. they are dispatched within
24 hours.

DT

Meaning

Preferred type

Normal quantities of the products are usually delivered within the specified time following receipt of your
order at our branch.
In exceptional cases, the actual delivery period may differ from that specified.
The delivery periods apply up to the ramp at Siemens AG (products ready for dispatch).
The transport times depend on the destination and type of shipping. The standard shipping time for
Germany is one day.
The delivery time classes specified here represent the state at the time of publication. They are
permanently optimized. Up-to-date information can be found at www.siemens.com/industrymall.

Price units (PU)


The price unit defines the number of units, sets or meters to which the specified price and weight apply.

PS/P. unit (packaging size/packaging unit)


The packaging size/packaging unit defines the number, e. g. of units, sets or meters, for outer packaging.
The first digit in the PS/P. unit column (packaging size/packaging unit) indicates the minimum order quantity. You can only order this
specified quantity or a multiple thereof.
The second digit in the PS/P. unit column (packaging size/packaging unit) specifies the number of units contained in larger packaging
(e. g. in a carton). You must order this quantity or a multiple thereof if you want the item to be delivered in a larger packaging quantity.
Examples:
PS/P. unit

Meaning

1 unit

You can order one item or a multiple thereof.

5 units

For example, five units are packed in a bag. Because the bags cannot be opened, you can only order a multiple of
the quantity contained in the bag: 5, 10, 15, 20 etc.

5/100 units

One carton contains (for example) 20 bags, each containing 5 units, i. e. a total of 100 units. If only cartons are
available for delivery, you need to order a multiple of the carton quantity: 100, 200, 300, etc.
Ordering a quantity of 220 units, would produce the following delivery: two cartons, each containing 100 units
(= 200 units) and 4 bags, each containing 5 units (= 20 units).

1 set

A set comprises a defined scope of various parts.

Weight
The defined weight is the net weight in kg and refers to the price unit (PU).

Siemens LV 50 2012

9/5

Siemens AG 2012

Appendix
Further documentation

Overview
We regard product support as just as important as the products
and systems themselves.
Visit our site on the Internet for a comprehensive offering of support for low-voltage power distribution and electrical installation
products, such as
Operating instructions and manuals for direct download
Online registration for seminars and events
Up-to-date answers to your queries and problems
Software upgrades and updates for fast download
Telephone assistance in more than 190 countries
Photos and graphics for external use
and much more - all conveniently and easily accessible.
Address:
www.siemens.com/lowvoltage
You will find regularly updated information material such as
catalogues, customer magazines, brochures and trial versions
of software for low-voltage power distribution and electrical installation on the Internet at:
www.siemens.com/lowvoltage/infomaterial
Here, you can order your copy of the available documentation or
download it in common file formats (PDF, ZIP).

For your configuration systems we can provide technical and


graphic data in electronic form for the range of low-voltage
power distribution and electrical installation products:
CAx online generator
For the further processing of low-voltage power distribution and
electrical installation products in CAE/CAD systems the online
generator provides:
Technical product master data in CSV and Excel format
Graphic product data
- 2D dimensional drawings in DXF format
(other formats optional)
- 3D models in STEP format
- Internal circuit diagrams
- EPLAN electric P 8 macros
Documentation in the form of PDF files
- Product data sheets
- Manuals
- Operating instructions
- Characteristic curves
- Certificates
Product photos
Texts for tenders in GAEB and Text format.

www.siemens.com/cax

9/6

Siemens LV 50 2012

Siemens AG 2012

Appendix
Standards and approvals

Overview
Approvals, test certificates, characteristics
A daily updated overview of certificates available for low-voltage
power distribution and electrical installation products along with
additional technical documentation is available on the Internet
at:
www.siemens.com/lowvoltage/support

Product support: Characteristics

Product support: Approvals/certificates

Product standards (excerpt)


IEC

DIN EN

DIN VDE

Title

60947-1
60947-2
60947-3

60947-1
60947-2
60947-3

----

Low-voltage controlgear and switchgear: General rules


Circuit breakers
Switches, disconnectors, switch-disconnectors and fuse-combination units

60947-4-1
60947-4-2
60947-4-3

60947-4-1
60947-4-2
60947-4-3

----

Contactors and motor starters: Electromechanical contactors and motor starters


Contactors and motor starters: semiconductor motor controllers and starters, soft starters
AC semiconductor controllers and contactors for non-motor loads

60947-5-1
60947-5-2
60947-5-3
60947-5-5
60947-5-6

60947-5-1
60947-5-2
60947-5-3
60947-5-5
60947-5-6

------

60947-5-7
60947-5-8
60947-5-9

60947-5-7
60947-5-8
60947-5-9

----

Control circuit devices and switching elements: Electromechanical control circuit devices
Control circuit devices and switching elements: Proximity switches
Proximity switches (defined behavior under fault conditions)
EMERGENCY-STOP devices with mechanical latching function
Control circuit devices and switching elements - DC interface for proximity switches and
switching amplifiers (NAMUR)
Requirements for proximity switches with analog output
Enabling switches
Flow sensors

60947-6-1
60947-6-2

60947-6-1
60947-6-2

---

Multiple function equipment Transfer switching equipment


Multiple function equipment Control and protective switching devices (CPS)

60947-7-1
60947-7-2
60947-7-3

60947-7-1
60947-7-2
60947-7-3

----

Ancillary equipment: Terminal blocks for copper conductors


Ancillary equipment: Protective conductor terminal blocks for copper conductors
Ancillary equipment: Safety requirements for fuse terminal blocks

60947-8

60947-8

--

Control units for built-in thermal protection (PTC) for rotating electrical machines

62026-2

50295

--

Actuator Sensor interface (AS-i)

60269-1
60269-4

60269-1
60269-4

---

Low-voltage fuses: General requirements


Low-voltage fuses: Supplementary requirements for fuse-links for the protection of
semiconductor devices

60050-441

--

--

International Electrotechnical Vocabulary / Switchgear, controlgear and fuses

60439-1
60439-3
61439-1
61439-2
--

60439-1
60439-3
61439-1
61439-2
50274

--0660-600-1
0660-600-2
--

61140

61140

--

Low-voltage switchgear and controlgear assemblies: Type-tested and partially type-tested assemblies
Low-voltage switchgear and controlgear assemblies Distribution boards
Low-voltage switchgear and controlgear assemblies General part
Low-voltage switchgear and controlgear assemblies Power switchgear and controlgear assemblies
Low-voltage switchgear and controlgear assemblies - Protection against electric shock - Protection
against unintentional direct contact with hazardous live parts
Protection from electric shock - General requirements for apparatus and equipment

60664-1

60664-1

--

Insulation coordination for equipment within low-voltage systems;


Principles, requirements and tests

Siemens LV 50 2012

9/7

Siemens AG 2012

Appendix
Standards and approvals
IEC

DIN EN

DIN VDE

Title

60204-1
-60079-14

60204-1
50178
60079-14

----

60079-2

60079-2

--

Electrical equipment of machines: General requirements


Electronic equipment for use in power installations
Electrical apparatus for explosive gas atmospheres
Electrical installations in hazardous areas (other than mines)
Electrical apparatus for explosive gas atmospheres - Part 2 Pressurized enclosures M "p"

61810-1

61810-1

--

61812-1

61812-1

--

60999-1

60999-1

--

61558-1

61558-1

0570-11)

Safety of transformers, power supplies, reactors and similar products


- Part 1: General requirements and tests

61558-2-1

61558-2-1

0570-2-11)

61558-2-2
61558-2-4
61558-2-6
61558-2-9

61558-2-2
61558-2-4
61558-2-6
61558-2-9

0570-2-21)
0570-2-41)
0570-2-61)
1)

61558-2-12
61558-2-13
61558-2-15
61558-2-20

61558-2-12
61558-2-13
61558-2-15
61558-2-20

0570-2-121)
0570-2-131)
0570-2-151)
0570-2-201)

-Part 2-1: Particular requirements for separating transformers and power supplies
incorporating separating transformers for general applications
-Part 2-2: Particular requirements for control transformers
-Part 2-4: Particular requirements for isolating transformers for general applications
-Part 2-6: Particular requirements for safety isolating transformers for general applications
-Part 2-9: Particular requirements for transformers for class III handlamps,
for tungsten filament lamps
-Part 2-12: Particular requirements for constant voltage transformers
-Part 2-13: Particular requirements for auto transformers
-Part 2-15: Particular requirements for isolating transformers for the supply of medical locations
-Part 2-20: Particular requirements for small reactors

62041

62041

0570-101)

Safety of transformers, power supply units, reactors and similar products - EMC requirements

60076-11
--

60076-11
--

-0552

Power transformers - Part 11: Dry-type transformers


Specifications for variable-ratio transformers having current collectors which are moved transversely in the
direction of the windings

61000-4-1

61000-4-1

--

61000-6-3

61000-6-3

--

61000-6-4

61000-6-4

--

Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques;


Section 1: Overview of IEC 61000-4 series
Electromagnetic compatibility (EMC); Generic standards - Emission standard
for residential, commercial and light-industrial environments
Electromagnetic compatibility (EMC); Generic standards - Emission standard for industrial environments

60044-1

60044-1

--

Instrument transformers: Current transformers

1)

Electromechanical elementary relays (electromechanical non-specified time all-or-nothing relays);


General and safety-related requirements
Specified time relays for industrial use Part 1: Requirements and tests
Connecting devices - Electrical copper conductors; Safety requirements for screw-type and
screwless-type clamping units - Part 1: General requirements and particular requirements for clamping
units for conductors from 0.2 mm2 to 35 mm2

0570-2-9

VDE classification.

UL

CSA C22.2 ASME

JIS

Title

506
508
489
1012

-----

-----

-----

Specialty transformers
Industrial Control Equipment
Molded Case Circuit Breakers, Molded Case Switches, and Circuit Breaker Enclosures
Power units other than CLASS 2

1561
5085
60601-1

----

----

----

1604
-1059
-486A-486B --

----

----

Dry-Type General Purpose and Power Transformers


Low voltage Transformers
Medical Electrical Equipment, Part 1: General Requirements for Safety (IEC 60601, EN 60601,
VDE 0750-1)
Electrical Equipment for Use in CLASS I and II, Division 2 and CLASS III hazardous (Classified) Locations
Terminal Blocks
Wire Connectors

486E

--

--

--

Equipment Wiring Terminals for Use with Aluminium and/or Copper Conductors

50

--

--

--

Enclosures for Electrical Equipment. Non-Environmental considerations

-----

No. 66
No. 14
No. 5
No. 107-1

-----

-----

Specialty Transformers
Industrial Control Equipment
Molded Case Circuit Breakers, Molded Case Switches, and Circuit Breaker Enclosures
General Use Power Supplies

--

--

A17.5 / B 44.1 --

--

--

--

9/8

Siemens LV 50 2012

Elevator and Escalator Electrical Equipment

C 8201-4-1 Low-Voltage Switchgear and Controlgear; Contactors and Motor-Starters

Siemens AG 2012

Appendix
Standards and approvals

Quality management

Certificates

The quality management system of our IC LMV LV Business Unit


complies with the international standard EN ISO 9001.
The products and systems listed in this catalog are marketed
using a VDE-approved quality management system according
to ISO 9001.
VDE certificate
Siemens AG
Infrastructure & Cities Sector
Low and Medium Voltage Division
Low Voltage
Reg. No.: 40017/QM/03.06

Information on the certificates available (CE, UL, CSA, FM,


shipping authorizations) for low-voltage power distribution and
electrical installation products can be found on the Internet at:
www.siemens.com/lowvoltage/support
In the Entry List you can use the certificate type (general product
approval, explosion protection, test certificates, shipbuilding,...)
as a filter criterion.

Approval requirements valid in different countries


Siemens low-voltage switchgear and controlgear are designed,
manufactured and tested according to the relevant German
standards (DIN and VDE), IEC publications and European
standards (EN) as well as CSA and UL standards. The standards
assigned to the single devices are stated in the relevant parts of
this catalog.
As far as is economically viable, the requirements of the various
regulations valid in other countries are also taken into account in
the standard version of the equipment.
In some countries (see table below), an approval is required for
certain low-voltage switchgear and controlgear components.
Depending on market requirements, these components have
been submitted for approval to the authorized testing institutes.

In some cases, CSA for Canada and UL for the USA only
approve special switchgear versions. Such special versions are
listed separately from the standard versions in the individual
parts of this catalog.
For this equipment, partial limitations of the maximum permissible voltages, currents and ratings can be imposed, or special
approval and, in some cases, special identification is required.
For use on board ship, the specifications of the marine
classification societies must be observed (see table below). In
some cases, they require type tests of the components to be
approved.

Testing bodies, approval identification and approval requirements


Canada 1)

USA 1)

China

Government-appointed or private, officially


recognized testing bodies

CSA UL
(USA)

UL

CQC

Mark of conformity

Approval requirements

Notes

UL and CSA are authorized to grant approval certificates in accordance with Canadian and US regulations. Please note: These approvals are not recognized in many cases and additional approvals often
have to be obtained from the national testing authority.

c u cU
c UUS
c uUS

U
c UUS
c uUS
+

+
CCC

For more information about UL and CSA see page 9/10.


1)

For guide numbers and file numbers for the approvals, visit our website at
www.siemens.com/lowvoltage/support

Siemens LV 50 2012

9/9

Siemens AG 2012

Appendix
Standards and approvals

Marine classification societies


Germany

United
Kingdom

France

Norway

CIS

Italy

Poland

USA

Name

Germanischer
Lloyd

Lloyds
Register of
Shipping

Bureau
Veritas

Det Norske
Veritas

Russian
Maritime
Register of
Shipping

Registro
Italiano
Navale

Polski
Rejestre
Statkw

American
Bureau of
Shipping

Abbreviations

GL

LRS

BV

DNV

RMRS

RINA

PRS

ABS

CE marking
Manufacturers of products which fall within the subject area to
which EC directives apply must identify their products, operating
instructions or packaging with a CE marking.
The CE marking confirms that a product fulfills the appropriate
basic requirements of all pertinent directives. The marking is a
mandatory requirement for putting products into circulation
throughout the EU.

All the products in this catalog are in conformance with the EC


directives and bear the CE marking.
Low-voltage directive
EMC directive
Machinery directive
Ex protection directive
The CE marking: >.

Accident prevention
Test certificates and approvals from the BIA (German statutory
industrial accident insurance institution in Bonn) and from SUVA
(Swiss institute for accident prevention) are available for some
devices in safety control systems. For details, see the respective
product descriptions.

Special standards, for example the USA and Canada


In the USA and Canada, for machine tools and processing
machines in particular, supply lines are laid using rubber
insulated cables enclosed in heavy-duty steel piping similar to
that used for gas or water pipe systems.
The tubing system must be completely watertight and
electrically conductive (especially sleeving and elbows). Since
the tubing system can also be grounded, the cable entries of
enclosed units equipped with heavy-gauge or metric threads
must be fitted with metal adapters between these threads and
the tube thread. The necessary adapters are specified for the
switchgear as accessories; they should be ordered separately
unless otherwise specified.

The abbreviations are harmonized with IEC 60947-5-1 Annex 1


Table A.1 and correspond to the stated utilization categories.
For various switching devices detailed in the catalog, a note has
been included to the effect that, above a certain voltage, the
auxiliary switches/auxiliary contacts can only be used if they
have the same polarity. This means that the input terminals can
only be connected to the same pole of the control voltage, e. g.
"600 V AC above 300 V AC same polarity".

Low-voltage switchgear and controlgear for auxiliary circuits


(e. g. contactor relays, commanding and signaling devices and
auxiliary switches/auxiliary contacts in general) are usually only
approved by CSA and UL for "Heavy Duty" or "Standard Duty"
and are identified either with these specifications in addition to
the maximum permissible voltage or by using an abbreviation.
Different features of UL approvals (for USA and Canada)
Recognized Component

Listed Product

Devices are identified on the rating plate


using the "UL recognition mark":
U, cUUS
USA:
Canada:
cU, cUUS

Devices are identified using the "UL listing mark" on the rating plate
Canada: cu LISTED 165 C
e. g. USA: u LISTED 165 C
IND. CONT. EQ.
IND. CONT. EQ.
(165 C stands for: Siemens, I IA CD Business Unit, Amberg plant)

Devices are approved as modules for "factory wiring", i. e.:


as devices for installation in control systems, which are selected, installed,
wired and tested entirely by trained personnel in factories, workshops or
elsewhere, according to the operating conditions.

Devices are approved for "field wiring", i. e.:


As devices for installation in control systems, which are completely wired by
trained personnel in factories, workshops or elsewhere.
As single devices for sale in retail outlets in the USA/Canada.

If devices are u or cu approved as "listed products", they are also approved as U or cU "recognized components".

For more information about UL and CSA see page 9/9.

9/10

Siemens LV 50 2012

Siemens AG 2012

Appendix
Standards and approvals

Special standards in different countries


CCC approval

Argentina
In Argentina, the approval requirements are based on Resolution
92/98. Since April 1, 2001, circuit breakers and RCCBs require
approval.
Since April 1, 2002, protective switches up to In = 63 A and Umax
= 440 V require approval and must bear a mark of conformity.
GOST approval for Russia

Since August 1, 2003, CCC approval is required for many


products that are marketed in China.
Romania
In Romania, components which are used in public buildings
must be approved by the Romanian testing authority ICECON.
South Africa

A GOST approval is required for all products that are to be sold


in Russia. The GOST mark has been obligatory on the
packaging of all devices since mid-1998.

In South Africa there are approval requirements for circuit


breakers and busbar trunking systems. Such equipment must
bear a conformity mark.

All devices delivered to any part of the Russian Federation must


have this customs certification.
C-Tick licensing for Australia

The C-Tick license is required for marketing Siemens electronic


components in Australia. Electronic devices must provide proof
of EMC clearance in Australia, similar to the CE marking laid
down by the EMC directive applicable in the EU and bear the
"C-Tick" mark. These requirements have been in force since
October 1, 1999.

Overview of standards for cubicle systems and cubicle air-conditioning


Standard

dated

IEC 62208

2002-22-01

Empty enclosures for low-voltage switchgear and controlgear assemblies General requirements

DIN EN 50298

1999-06-01

Empty enclosures for low-voltage switchgear and controlgear assemblies


General requirements

DIN 41488-1

1971-03-01

Electrical engineering; switchboard dimensions


(standard withdrawn)

DIN 41488-2

1972-08-01

Electrical engineering; switchboard dimensions

DIN 43656

1979-01-01

Indoor switchgear and controlgear assemblies and high-voltage switchgear and controlgear up to 36 kV; colouring

DIN 43668

1964-11-01

Keys for the doors of electrical switchgear cubicles and cabinets; double-bit key

Quality test certificate/Declaration of conformity according


to DIN 6700
This specification describes the rules for the quality assurance
of welded connections for components which are used on rail
vehicles.

The 8MF special cubicle racks (not the standard versions) meet
the requirements according to DIN 6700, Component Class C2
- "Rail vehicles with high safety significance".
Suitable requirements on quality, production and documentation
are agreed between the customer and the manufacturer.

Further information
You can find more information on standards and approvals at:
www.siemens.com/lowvoltage/support

Siemens LV 50 2012

9/11

Siemens AG 2012

Appendix
Siemens Contacts

Contact partners at Siemens Industry


At Siemens Industry Automation and Drive Technologies, more
than 85 000 people are resolutely pursuing the same goal: longterm improvement of your competitive ability. We are committed
to this goal. Thanks to our commitment, we continue to set new
standards in automation and drive technology. In all industries
worldwide.
At your service locally, around the globe for consulting, sales,
training, service, support, spare parts ... on the entire Industry
Automation and Drive Technologies range.
Your personal contact can be found in our Contacts Database at:
www.siemens.com/automation/partner
You start by selecting a
Product group,
Country,
City,
Service.

9/12

Siemens LV 50 2012

Siemens AG 2012

Appendix
Online Services: Information and ordering
on the internet and on DVD

Low-Voltage Power Distribution and Electrical Installation Technology on the WWW


Siemens low-voltage power distribution and electrical installation technology offers switchboards, busbar trunking systems,
distribution boards as well as protection, switching, measuring
and monitoring devices, building management systems,
switches and socket outlets. The consistency, modularity and
intelligence of our components and systems offer you numerous
advantages throughout their service life and wherever you are
in the world. We deliver trendsetting designs and innovative
functions in unique quality, developed in accordance with the
applicable international standards.
Comprehensive information about all products and systems as
well as service and support is available in a compact and clear
format on the Internet at:
www.siemens.com/lowvoltage

Product selection using the interactive catalog CA 01 of Industry


Detailed information together with convenient interactive
functions:
The interactive catalog CA 01 covers more than 80 000 products
and thus provides a full summary of the Siemens Industry Automation and Drive Technologies product base.
Here you will find everything that you need to solve tasks in the
fields of automation, switchgear, installation and drives.
All information is linked into a user interface which is easy to
work with and intuitive.
After selecting the product of your choice you can order at the
press of a button, by fax or by online link.
Information on the interactive catalog CA 01 can be found on the
Internet under
www.siemens.com/automation/ca01
or on DVD.

Easy Shopping with the Industry Mall


The Industry Mall is the virtual department store of Siemens AG
on the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way.
Data transfer via EDIFACT allows the whole procedure from
selection through ordering to tracking of the order to be carried
out online via the Internet.
Numerous functions are available to support you.
For example, powerful search functions make it easy to find the
required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes
can be carried out online as well as order tracking and tracing.
Please visit the Industry Mall on the Internet under:
www.siemens.com/industrymall

Siemens LV 50 2012

9/13

Siemens AG 2012

Appendix
Online Services:
Social Media and Mobile Media

Social Media
Connect with Siemens through social media: visit our social networking sites for a wealth of useful information, demos on products and services, the opportunity to provide feedback, to exchange information and ideas with customers and other
Siemens employees, and much, much more. Stay in the know
and follow us on the ever-expanding global network of social
media.
Connect with Siemens Industry at our central access point:
www.siemens.com/industry/socialmedia
Or via our product pages at:
www.siemens.com/automation
or
www.siemens.com/drives
To find out more about Siemens' current social media activities
visit us at:
www.siemens.com/socialmedia

Mobile Media
We are also constantly expanding our offering of cross-platform
apps for smartphones and tablets. You will find the current Siemens apps at your app store.

9/14

Siemens LV 50 2012

Siemens AG 2012

Appendix
Service & Support
The unmatched complete service
for the entire life cycle
Training

ld
Fie vice
r
Se
Modernization
Services

Optimization
Services

Service
Programs

Our Service & Support are available worldwide to help you with
every aspect of Siemens Building and Automation Technologies.
We offer on-site support for every phase of the life cycle of your
buildings and plants in more than 100 countries.

Tec
Sup hnical
por t

Sp
ar
e

t
pp or
e Su
Onlin

Pa
r ts

Technical
Consulting

Engineering
Support

Online support

Every step of the way, you have access to an experienced team


of specialists and their combined expertise. Thanks to regular
training and the close cooperation of key employees around the
globe, we are able to offer reliable services for a huge range of
options.

Field Service
Our comprehensive online information platform covers every
aspect of our Service & Support
and is available whenever,
wherever.

Siemens Field Service offers


support with all aspects of commissioning and maintenance
so that the availability of your
machines and plants is assured
whatever the case.

www.siemens.com/lowvoltage/
support

Technical support

www.siemens.com/lowvoltage/
technical-support

Spare parts
The competent consulting service for technical issues with a
broad range of customer-oriented services for all our products
and systems.

Plants and systems in all sectors


worldwide are expected to meet
ever higher levels of availability.
We can help you rule out unexpected stoppages with a global
network and optimum logistics
chains.

www.siemens.com/lowvoltage/
technical-support

www.siemens.com/lowvoltage/
technical-support

Specification texts

Training
Extend your lead with practiserelated know-how straight from
the manufacturer.

You can obtain qualified, free support to help you produce


specifications for technically equipping non-residential and
industrial buildings at

www.siemens.com/lowvoltage/
training

www.automation.siemens.com/mcms/tender-specifications/en

Siemens LV 50 2012

9/15

Siemens AG 2012

Appendix
Service & Support
Comprehensive support from A to Z

Overview
Product information
Fast, targeted information on low-voltage power
distribution:

Website

www.siemens.com/lowvoltage
Always up to date about our trend-setting products
and systems:

Newsletter

www.siemens.com/lowvoltage/newsletter

Product information/product & system selection


Information and
Download Center

Current catalogs, customer magazines, brochures,


demo software and promotion packages:
www.siemens.com/lowvoltage/infomaterial

Industry Mall

Comprehensive information and order platform for


the Siemens Industry Basket:
www.siemens.com/lowvoltage/mall

Product & system engineering


SIMARIS
software tools

Support in planning and configuration the electrical


power distribution:
www.siemens.com/simaris

ALPHA SELECT
Simple and fast configuration for distribution boards
engineering software and metre cabinets with products from the Siemens
Industry Basket:
www.siemens.com/alpha-select

Product documentation
Service & Support
portal

Comprehensive technical information - from planning


to configuration and operation:
www.siemens.com/lowvoltage/support
Collation of commercial and technical master product data:

CAx Data

www.siemens.com/cax
Image database

Collection of product photographs and graphics,


such as dimensional drawings and internal circuit
diagrams:
www.siemens.com/lowvoltage/bilddb

Product training
SITRAIN portal

Comprehensive training program about our products, systems and engineering tools:
www.siemens.com/lowvoltage/training

Product hotline

Technical Support

Support for all technical queries about our products:


E-mail: support.automation@siemens.com
www.siemens.com/lowvoltage/technical-support

9/16

Siemens LV 50 2012

Siemens AG 2012

Appendix
Software Licenses

Overview
Software types
Software requiring a license is categorized into types.
The following software types have been defined:
Engineering software
Runtime software
Engineering software
This includes all software products for creating (engineering)
user software, e.g. for configuring, programming, parameterizing, testing, commissioning or servicing.
Data generated with engineering software and executable
programs can be duplicated for your own use or for use by thirdparties free-of-charge.
Runtime software
This includes all software products required for plant/machine
operation, e.g. operating system, basic system, system expansions, drivers, etc.
The duplication of the runtime software and executable programs created with the runtime software for your own use or for
use by third-parties is subject to a charge.
You can find information about license fees according to use in
the ordering data (e.g. in the catalog). Examples of categories of
use include per CPU, per installation, per channel, per instance,
per axis, per control loop, per variable, etc.
Information about extended rights of use for parameterization/configuration tools supplied as integral components of the
scope of delivery can be found in the readme file supplied with
the relevant product(s).
License types
Siemens Industry Automation & Drive Technologies offers various types of software license:
Floating license
Single license
Rental license
Rental floating license
Trial license
Demo license
Demo floating license
Floating license
The software may be installed for internal use on any number of
devices by the licensee. Only the concurrent user is licensed.
The concurrent user is the person using the program. Use
begins when the software is started.
A license is required for each concurrent user.
Single license
Unlike the floating license, a single license permits only one
installation of the software per license.
The type of use licensed is specified in the ordering data and
in the Certificate of License (CoL). Types of use include for
example per instance, per axis, per channel, etc.
One single license is required for each type of use defined.
Rental license
A rental license supports the "sporadic use" of engineering
software. Once the license key has been installed, the software
can be used for a specific period of time (the operating hours do
not have to be consecutive).
One license is required for each installation of the software.

Rental floating license


The rental floating license corresponds to the rental license,
except that a license is not required for each installation of the
software. Rather, one license is required per object (for example,
user or device).
Trial license
A trial license supports "short-term use" of the software in a nonproductive context, e.g. for testing and evaluation purposes.
It can be transferred to another license.
Demo license
The demo license support the "sporadic use" of engineering software in a non-productive context, for example, use for testing
and evaluation purposes. It can be transferred to another
license. After the installation of the license key, the software can
be operated for a specific period of time, whereby usage can be
interrupted as often as required.
One license is required per installation of the software.
Demo floating license
The demo floating license corresponds to the demo license,
except that a license is not required for each installation of the
software. Rather, one license is required per object (for example,
user or device).
Certificate of license (CoL)
The CoL is the licensee's proof that the use of the software has
been licensed by Siemens. A CoL is required for every type of
use and must be kept in a safe place.
Downgrading
The licensee is permitted to use the software or an earlier version/release of the software, provided that the licensee owns
such a version/release and its use is technically feasible.
Delivery versions
Software is constantly being updated.
The following delivery versions
PowerPack
Upgrade
can be used to access updates.
Existing bug fixes are supplied with the ServicePack version.
PowerPack
PowerPacks can be used to upgrade to more powerful software.
The licensee receives a new license agreement and CoL
(Certificate of License) with the PowerPack. This CoL, together
with the CoL for the original product, proves that the new software is licensed.
A separate PowerPack must be purchased for each original
license of the software to be replaced.
Upgrade
An upgrade permits the use of a new version of the software on
the condition that a license for a previous version of the product
is already held.
The licensee receives a new license agreement and CoL with
the upgrade. This CoL, together with the CoL for the previous
product, proves that the new version is licensed.
A separate upgrade must be purchased for each original license
of the software to be upgraded.

Siemens LV 50 2012

9/17

Siemens AG 2012

Appendix
Software Licenses

Overview
ServicePack
ServicePacks are used to debug existing products.
ServicePacks may be duplicated for use as prescribed according to the number of existing original licenses.
License key
Siemens Industry Automation & Drive Technologies supplies
software products with and without license keys.
The license key serves as an electronic license stamp and
is also the "switch" for activating the software (floating license,
rental license, etc.).
The complete installation of software products requiring license
keys includes the program to be licensed (the software) and the
license key (which represents the license).

9/18

Siemens LV 50 2012

Software Update Service (SUS)


As part of the SUS contract, all software updates for the respective product are made available to you free of charge for a period
of one year from the invoice date. The contract will automatically
be extended for one year if it is not canceled three months
before it expires.
The possession of the current version of the respective software
is a basic condition for entering into an SUS contract.
You can download explanations concerning license conditions from
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf

Siemens AG 2012

Appendix
Subject index
Numerics

19" punched bars ....................................... 4/12


19" shelves .................................................. 4/13
8MC, 8MF cubicle systems ...................1/2, 2/5
8MF cubicle systems .................................... 1/3
8MF ventilation, with "Masterdrive"
perforation .................................................... 3/4
8MR air-conditioning ..................................... 8/2

Definition of EMC ...........................................5/9


Degrees of protection ...................................1/2
Design of an EMC cubicle ............................5/9
Device panel ...............................................4/14
Device plate with standard mounting rail
and cable ducts ..........................................4/11
Door position switch ....................................4/17
Door position switch plate ...........................4/15
Door stay .....................................................3/16
Dual lights
For 8MC, 8MF ...........................................7/2

Grounding ................................................... 4/16


Gusset plates/fixing brackets ....................... 4/5

A
Actuator pin ................................................ 3/15
Air conditioners/cooling devices
Cooling devices for door or side mounting 8/7
Cooling devices for roof mounting ........... 8/7
AVE
Project ...................................................... 6/4
B
Base parts .................................................... 4/2
Base plates ................................................... 4/2
Brackets for center fixing of a
mounting panel ............................................. 4/8
C
Cable ducts according to DIN 43 659,
form B ......................................................... 4/10
Circuit diagram pocket ............................... 4/17
Compact lights
For 8MC, 8MF ........................................... 7/2
Control systems
Cubicles for .......................................6/2, 6/5
Cooling units
Cubicles with ............................................ 6/5
Cover plates for swing frames .................... 4/14
CP2000
Project ...................................................... 6/3
C-profile bars/cable clamping bars .............. 4/6
Crossbars for swing frames ........................ 4/12
Cubicle air-conditioning ................................ 8/9
Cubicle interconnections .............................. 2/8
Assembly kits ........................................... 2/8
Cubicle suites ........................................... 2/8
Sealing material ........................................ 2/8
Cubicle lighting ............................................. 7/2
For 8MC, 8MF ........................................... 7/2
Cubicle modification
8MF ventilation, with "Masterdrive"
perforation ................................................ 3/4
Actuator pin in place of a double-bit ...... 3/15
Asymmetrically divided double-wing door
in place of a rear panel ............................ 3/8
Lock insert in place of a double-bit ........ 3/15
Symmetrically divided double-wing door
in place of a rear panel ............................ 3/7
Ventilation gills (SBL) ................................ 3/4
Ventilation slots, 8MF ................................ 3/4
Cubicle suites ............................................... 2/8
Cubicles
Control systems ........................................ 6/5
Cooling units ............................................. 6/5
Heat exchangers ...................................... 6/5
LSA ........................................................... 6/2
Protection and control systems ................ 6/2
Special ...............................................6/2, 6/5
Special applications
- Protection and control systems ............. 6/2
Transportation systems .....................6/3, 6/4
Customizing of enclosure parts .................... 3/3

E
Earthquake-resistant version .......................5/12
Electromagnetic compatibility (EMC) ............5/9
Electronic hygrostats ...................................8/13
Electronic hygrotherms ...............................8/14
Electronic thermostats .................................8/13
EMC filter fans ...............................................8/4
Enclosure parts, customizing ........................3/3
Espagnolette lock accessory set ................3/15
Exteriors ........................................................4/2

H
Handle ........................................................ 3/15
Heat exchangers
Air/air heat exchangers ............................ 8/8
Cubicles with ............................................ 6/5
Heater plate ................................................ 4/15
Heavy-duty swing frames ........................... 4/13
Hygrostats .................................................. 8/12
Hygrotherms ............................................... 8/12
I
Installation notes for EMC-compliant
configuration ............................................... 5/11
Installation plates .......................................... 4/8
Integrated lights
For 8MC, 8MF ........................................... 7/2
Interference emission and interference
immunity ..................................................... 5/11
Interiors ......................................................... 4/4
K

F
Fan heaters .................................................8/10
Fastening plates ..........................................4/15
Feet ...............................................................4/2
Filter fan versions ..........................................8/4
Filter fans
19" withdrawable fan unit ..........................8/6
Filter fans ..................................................8/4
Filter mats .................................................8/6
Outlet filters ...............................................8/5
Roof filter fans ...........................................8/6
Fixing kit for circuit breakers .......................4/10
Foam rubber profile ........................... 3/10, 3/11

Keys ............................................................ 3/15


L
Lamp plate .................................................. 4/15
Lights
For 8MC, 8MF ........................................... 7/2
Lock ............................................................ 3/15
Lock insert .................................................. 3/15
Lock trim ..................................................... 4/13
Locking rods ............................................... 3/15
Locking systems ......................................... 3/15
LSA cubicles ................................................. 6/2

Siemens LV 50 2012

9/19

Siemens AG 2012

Appendix
Subject index
M

Mechanical hygrostats ................................ 8/13


Mechanical thermostats ............................. 8/13
Mounting panel ............................................. 4/8
Mounting plates ............................................ 4/9
Mounting strips ............................................. 4/6
Multi-purpose door bars ............................. 4/11

Scope of delivery 8MF2 .............................5/2


Scope of delivery 8MF2, 8MF5/6 ...............5/4
Screwing together two cubicles ....................2/8
Sealing strip ................................................4/17
Semiconductor heater units
With thermostat .........................................8/9
Without thermostat ....................................8/9
Separation panel ...........................................4/4
Serrated bar ..................................................4/7
Serrated bars ................................................4/7
Shelves ..........................................................4/4
Side mounting plates ..................................4/10
Side panel .....................................................3/9
Slimline lights ................................................7/2
For 8MC, 8MF ...........................................7/3
Small thermostats ........................................8/12
Special applications
Cubicles
- Protection and control systems ..............6/2
Special cubicles .................................... 6/2, 6/5
Standard door ...............................................3/7
Standard filter fans in EMC version ...............8/4
Standard mounting rails ..............................4/11
Supporting bars ............................................4/5
Swing frames ...............................................4/12
Switching modules ......................................8/14
System cubicles ............................. 1/2, 1/3, 2/5

Tamper-proof thermostats ........................... 8/12


Telescopic rails ............................................. 4/5
Thermostat plate ......................................... 4/15
Thermostats ................................................ 8/12
Transport aids ............................................... 4/3
Transport brackets ........................................ 4/3
Transport eyebolts ........................................ 4/3
Transport rails ............................................... 4/3
Transportation systems
Cubicles for ....................................... 6/3, 6/4
Twin thermostats ......................................... 8/13

O
Order designation 8MF5, 8MF6 ............... 5/10
Order designations of the standard
versions 8MF2 , 8MF5/6 ...................... 5/2, 5/4
P
Partition panel ............................................... 4/4
Perforated roof plates ................................. 3/13
Perforated ventilation roofs ......................... 3/14
Plinths ........................................................... 4/2
Plug-on mounts ............................................. 7/2
For 8MC, 8MF ........................................... 7/2
Principles of EMC ....................................... 5/11
Project
AVE ........................................................... 6/4
CP2000 ..................................................... 6/3
Protection and control systems
Special applications
- Cubicles ................................................ 6/2
Protection systems, cubicles for ................... 6/2
PTC fan heaters .......................................... 8/11
Punched bars ............................................. 4/12

9/20

Siemens LV 50 2012

U
Universal fixings/fixing brackets ................... 4/5
V
Ventilated cubicles ....................................... 5/2
Ventilation cross-sections
In roof plate 8MF2 ................................. 5/3
In the doors 8MF2 ................................. 5/3
Ventilation gills (SBL) .................................... 3/4
Ventilation slots, 8MF .................................... 3/4
Vertical profile bar ......................................... 4/6
W
Welding standard SGK 2.2 ........................... 6/3

Siemens AG 2012

Appendix
Order No. index
including Export markings

Overview
Order No.

Page

Export markings*

Order No.

Page

ECCN

AL

8MC4

8MF2 068-4E

2/4

8MC4 300

8MF2 068-4R

2/4

8ME1, 8ME8

8MF2 068-5E

5/6

8ME1 461

8MF2 068-5R

5/6

8MF2 084-4E

2/4

2/4

ECCN

8ME1 462

3/16

4/5
4/5

N
N

AL

Export markings*

8ME1 463

4/5

8MF2 084-4R

8ME1 464

4/5

8MF2 084-5E

5/6

8ME1 465

4/5

8MF2 084-5R

5/6

8ME1 466

4/5

8MF2 086-4E

2/4

8ME1 467

4/5

8MF2 086-4R

2/4

8ME1 468

4/5

8MF2 086-5E

5/6

8ME1 470

4/5

8MF2 086-5R

5/6

8ME1 471

4/5

8MF2 088-4E

2/4

8ME1 472

4/5

8MF2 088-4R

2/4

8ME8 468

3/15

8MF2 088-5E

5/6

8ME8 473

3/15

8MF2 088-5R

5/6

8ME8 811

4/5

8MF2 094-4E

2/4

8ME8 812

4/5

8MF2 094-4R

2/4

8ME8 813

4/5

8MF2 094-5E

5/6

8MF2 0

8MF2 094-5R

5/6

8MF2 004-4E

8MF2 096-4E

2/4

8MF2 096-4R

2/4

8MF2 096-5E

5/6

8MF2 096-5R

5/6

8MF2 098-4E

2/4

8MF2 098-4R

2/4

8MF2 098-5E

5/6

8MF2 098-5R

5/6

8MF2 2

8MF2 004-4R
8MF2 004-5E
8MF2 004-5R
8MF2 006-4E
8MF2 006-4R
8MF2 006-5E
8MF2 006-5R

2/4
2/4
5/6
5/6
2/4
2/4
5/6
5/6

N
N
N
N
N
N
N
N

8MF2 008-4E

2/4

8MF2 008-4R

2/4

8MF2 204-4E

2/4

8MF2 204-4R

2/4

8MF2 204-5E

5/6

8MF2 204-5R

5/6

8MF2 206-4E

2/4

2/4

8MF2 008-5E
8MF2 008-5R
8MF2 024-4E
8MF2 024-4R

5/6
5/6
2/4
2/4

N
N
N
N

8MF2 024-5E

5/6

8MF2 206-4R

8MF2 024-5R

5/6

8MF2 206-5E

5/6

8MF2 026-4E

2/4

8MF2 206-5R

5/6

8MF2 026-4R

2/4

8MF2 208-4E

2/4

8MF2 026-5E

5/6

8MF2 208-4R

2/4

8MF2 026-5R

5/6

8MF2 208-5E

5/6

8MF2 028-4E

2/4

8MF2 208-5R

5/6

8MF2 028-4R

2/4

8MF2 224-4E

2/4

8MF2 028-5E

5/6

8MF2 224-4R

2/4

8MF2 028-5R

5/6

8MF2 224-5E

5/6

8MF2 064-4E

2/4

8MF2 224-5R

5/6

8MF2 064-4R

2/4

8MF2 226-4E

2/4

8MF2 064-5E

5/6

8MF2 226-4R

2/4

8MF2 064-5R

5/6

8MF2 226-5E

5/6

8MF2 066-4E

2/4

8MF2 226-5R

5/6

8MF2 066-4R

2/4

8MF2 228-4E

2/4

8MF2 066-5E

5/6

8MF2 228-4R

2/4

8MF2 066-5R

5/6

8MF2 228-5E

5/6

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens LV 50 2012

9/21

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*

Page

Export markings*
ECCN

AL

5/6

8MF2 824-5R

5/6

8MF2 264-4E

2/4

8MF2 826-4E

2/4

8MF2 264-4R

2/4

8MF2 826-4R

2/4

8MF2 264-5E

5/6

8MF2 826-5E

5/6

8MF2 264-5R

5/6

8MF2 826-5R

5/6

8MF2 266-4E

2/4

8MF2 828-4E

2/4

8MF2 266-4R

2/4

8MF2 828-4R

2/4

8MF2 266-5E

5/6

8MF2 828-5E

5/6

8MF2 266-5R

5/6

8MF2 828-5R

5/6

8MF2 268-4E

2/4

8MF2 864-4E

2/4

8MF2 268-4R

2/4

8MF2 864-4R

2/4

8MF2 268-5E

5/6

8MF2 864-5E

5/6

8MF2 268-5R

5/6

8MF2 864-5R

5/6

8MF2 284-4E

2/4

8MF2 866-4E

2/4

8MF2 284-4R

2/4

8MF2 866-4R

2/4

8MF2 284-5E

5/6

8MF2 866-5E

5/6

8MF2 284-5R

5/6

8MF2 866-5R

5/6

8MF2 286-4E

2/4

8MF2 868-4E

2/4

8MF2 286-4R

2/4

8MF2 868-4R

2/4

8MF2 286-5E

5/6

8MF2 868-5E

5/6

8MF2 286-5R

5/6

8MF2 868-5R

5/6

8MF2 288-4E

2/4

8MF2 884-4E

2/4

8MF2 288-4R

2/4

8MF2 884-4R

2/4

8MF2 288-5E

5/6

8MF2 884-5E

5/6

8MF2 288-5R

5/6

8MF2 884-5R

5/6

8MF2 294-4E

2/4

8MF2 886-4E

2/4

8MF2 294-4R

2/4

8MF2 886-4R

2/4

8MF2 294-5E

5/6

8MF2 886-5E

5/6

8MF2 294-5R

5/6

8MF2 886-5R

5/6

8MF2 296-4E

2/4

8MF2 888-4E

2/4

8MF2 296-4R

2/4

8MF2 888-4R

2/4

8MF2 296-5E

5/6

8MF2 888-5E

5/6

8MF2 296-5R

5/6

8MF2 888-5R

5/6

8MF2 298-4E

2/4

8MF2 894-4E

2/4

8MF2 298-4R

2/4

8MF2 894-4R

2/4

8MF2 298-5E

5/6

8MF2 894-5E

5/6

8MF2 298-5R

5/6

8MF2 894-5R

5/6

8MF2 8

8MF2 896-4E

2/4

8MF2 804-4E

8MF2 896-4R

2/4

8MF2 896-5E

5/6

8MF2 896-5R

5/6

2/4

8MF2 804-4R
8MF2 804-5E

2/4
5/6

AL

Order No.

8MF2 228-5R

2/4

ECCN

N
N
N

8MF2 804-5R

5/6

8MF2 898-4E

8MF2 806-4E

2/4

8MF2 898-4R

2/4

8MF2 806-4R

2/4

8MF2 898-5E

5/6

8MF2 806-5E

5/6

8MF2 898-5R

5/6

8MF2 806-5R

5/6

8MF3 0

8MF2 808-4E

2/4

8MF3 040

3/5

8MF2 808-4R

2/4

8MF3 041

3/5

8MF2 808-5E

5/6

8MF3 042

3/5

8MF2 808-5R

5/6

8MF3 043

3/5

8MF2 824-4E

2/4

8MF3 044

3/5

8MF2 824-4R

2/4

8MF3 045

3/5

8MF2 824-5E

5/6

8MF3 046

3/5

9/22

Siemens LV 50 2012

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

Order No.

Page

Export markings*
ECCN

AL

8MF3 047

3/5

8MF3 213

3/7

8MF3 048

3/5

8MF3 214

3/7

8MF3 050

3/5

8MF3 215

3/7

8MF3 051

3/5

8MF3 216

3/7

8MF3 052

3/5

8MF3 220

3/7

8MF3 053

3/5

8MF3 221

3/7

8MF3 054

3/5

8MF3 222

3/7

8MF3 055

3/5

8MF3 223

3/7

8MF3 056

3/5

8MF3 224

3/7

8MF3 057

3/5

8MF3 226

3/7

8MF3 058

3/5

8MF3 227

3/7

8MF3 228

3/7

8MF3 1
8MF3 100

3/15

8MF3 230

3/7

8MF3 101

3/15

8MF3 231

3/7

8MF3 102

3/15

8MF3 232

3/7

8MF3 103

3/15

8MF3 233

3/7

8MF3 104

3/15

8MF3 234

3/7

8MF3 105

3/15

8MF3 235

3/7

8MF3 110

3/15

8MF3 236

3/7

8MF3 111

3/15

8MF3 240

3/7

8MF3 112

3/15

8MF3 241

3/7

8MF3 113

3/15

8MF3 242

3/7

8MF3 114

3/15

8MF3 243

3/7

8MF3 121

3/5

8MF3 244

3/7

8MF3 122

3/5

8MF3 245

3/7

8MF3 123

3/5

8MF3 246

3/7

8MF3 124

3/5

8MF3 247

3/7

8MF3 125

3/5

8MF3 248

3/7

8MF3 126

3/5

8MF3 250

3/7

8MF3 127

3/5

8MF3 251

3/7

8MF3 128

3/5

8MF3 252

3/7

8MF3 130

3/5

8MF3 253

3/8

8MF3 254

3/8

8MF3 255

3/8

8MF3 256

3/8

8MF3 257

3/8

3/8

8MF3 131
8MF3 132
8MF3 133
8MF3 134

3/5
3/5
3/5
3/5

N
N
N
N

8MF3 135

3/5

8MF3 258

8MF3 136

3/5

8MF3 3

8MF3 137

3/5

8MF3 321

3/8

8MF3 138

3/5

8MF3 322

3/8

8MF3 140

3/5

8MF3 323

3/8

8MF3 324

3/8

8MF3 2
8MF3 200

3/7

8MF3 325

3/8

8MF3 201

3/7

8MF3 326

3/8

8MF3 202

3/7

8MF3 327

3/8

8MF3 203

3/7

8MF3 328

3/8

8MF3 204

3/7

8MF3 330

3/8

8MF3 206

3/7

8MF3 331

3/8

8MF3 207

3/7

8MF3 332

3/8

8MF3 208

3/7

8MF3 333

3/8

8MF3 210

3/7

8MF3 334

3/8

8MF3 211

3/7

8MF3 335

3/8

8MF3 212

3/7

8MF3 336

3/8

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens LV 50 2012

9/23

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

Page

Export markings*
ECCN

AL

8MF3 337

3/8

8MF3 466

3/14

8MF3 338

3/8

8MF3 467

3/14

8MF3 340

3/8

8MF3 470

3/14

8MF3 471

3/14

8MF3 4

Order No.

8MF3 400

3/13

8MF3 472

3/14

8MF3 401

3/13

8MF3 473

3/14

8MF3 402

3/13

8MF3 474

3/14

8MF3 405

3/13

8MF3 475

3/14

8MF3 406

3/13

8MF3 476

3/14

8MF3 407

3/13

8MF3 477

3/14

8MF3 410

3/13

8MF3 478

3/14

8MF3 411

3/13

8MF3 480

3/11

8MF3 412

3/13

8MF3 481

3/11

8MF3 413

3/13

8MF3 482

3/11

8MF3 414

3/13

8MF3 485

3/11

8MF3 415

3/13

8MF3 486

3/11

8MF3 416

3/13

8MF3 487

3/11

8MF3 417

3/13

8MF3 490

3/11

8MF3 418

3/13

8MF3 491

3/11

8MF3 420

3/13

8MF3 492

3/11

8MF3 421

3/13

8MF3 493

3/11

8MF3 422

3/13

8MF3 494

3/11

8MF3 425

3/13

8MF3 495

3/11

8MF3 426

3/13

8MF3 496

3/11

8MF3 427

3/13

8MF3 497

3/11

8MF3 430

3/13

8MF3 498

3/11

8MF3 431

3/13

8MF3 5

8MF3 432

3/13

8MF3 500

3/10, 3/11

8MF3 433

3/13

8MF3 510

3/12

8MF3 434

3/13

8MF3 511

3/12

8MF3 435

3/13

8MF3 513

3/12

8MF3 436

3/13

8MF3 514

3/12

8MF3 437

3/13

8MF3 516

3/12

8MF3 438

3/13

8MF3 517

3/12

8MF3 440

3/14

8MF3 518

3/12

8MF3 441

3/14

8MF3 520

3/12

8MF3 442

3/14

8MF3 521

3/12

8MF3 445

3/14

8MF3 522

3/12

8MF3 446

3/14

8MF3 527

3/12

8MF3 447

3/14

8MF3 528

3/12

8MF3 450

3/14

8MF4 0

8MF3 451

3/14

8MF4 010

4/2

8MF3 452

3/14

8MF4 011

4/2

8MF3 453

3/14

8MF4 012

4/2

8MF3 454

3/14

8MF4 015

4/2

8MF3 455

3/14

8MF4 016

4/2

8MF3 456

3/14

8MF4 017

4/2

8MF3 457

3/14

8MF4 020

4/2

8MF3 458

3/14

8MF4 021

4/2

8MF3 460

3/14

8MF4 022

4/2

8MF3 461

3/14

8MF4 023

4/2

8MF3 462

3/14

8MF4 024

4/2

8MF3 465

3/14

8MF4 025

4/2

9/24

Siemens LV 50 2012

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

Order No.

Page

Export markings*
ECCN

AL

8MF4 026

4/2

8MF4 107

3/10

8MF4 027

4/2

8MF4 111

3/10

8MF4 028

4/2

8MF4 112

3/10

8MF4 030

4/2

8MF4 114

3/10

8MF4 031

4/2

8MF4 115

3/10

8MF4 032

4/2

8MF4 117

3/10

8MF4 035

4/2

8MF4 118

3/10

8MF4 036

4/2

8MF4 120

3/9

8MF4 037

4/2

8MF4 121

3/9

8MF4 040

4/2

8MF4 122

3/9

8MF4 041

4/2

8MF4 125

3/9

8MF4 042

4/2

8MF4 126

3/9

8MF4 043

4/2

8MF4 127

3/9

8MF4 044

4/2

8MF4 130

3/9

8MF4 045

4/2

8MF4 131

3/9

8MF4 046

4/2

8MF4 132

3/9

8MF4 047

4/2

8MF4 135

3/9

8MF4 048

4/2

8MF4 136

3/9

8MF4 050

4/2

8MF4 137

3/9

8MF4 060

3/10

8MF4 140

3/9

8MF4 061

3/10

8MF4 141

3/9

8MF4 062

3/10

8MF4 142

3/9

8MF4 065

3/10

8MF4 145

3/9

8MF4 066

3/10

8MF4 146

3/9

8MF4 067

3/10

8MF4 147

3/9

8MF4 070

3/10

8MF4 150

4/4

8MF4 071

3/10

8MF4 151

4/4

8MF4 072

3/10

8MF4 152

4/4

8MF4 073

3/10

8MF4 160

4/4

8MF4 074

3/10

8MF4 161

4/4

8MF4 075

3/10

8MF4 162

4/4

8MF4 076

3/10

8MF4 170

4/4

8MF4 077

3/10

8MF4 171

4/4

8MF4 078

3/10

8MF4 172

4/4

8MF4 080

3/10

8MF4 2

8MF4 081

3/10

8MF4 220

4/3

8MF4 082

3/10

8MF4 221

4/3

8MF4 085

3/10

8MF4 222

4/3

8MF4 086

3/10

8MF4 225

4/3

8MF4 087

3/10

8MF4 226

4/3

8MF4 090

3/10

8MF4 3

8MF4 091

3/10

8MF4 301

4/17

8MF4 092

3/10

8MF4 302

4/17

8MF4 093

3/10

8MF4 303

4/17

8MF4 094

3/10

8MF4 304

4/17

8MF4 095

3/10

8MF4 310

4/17

8MF4 096

3/10

8MF4 311

4/17

8MF4 097

3/10

8MF4 320

4/11

8MF4 098

3/10

8MF4 321

4/11

8MF4 322

4/11

8MF4 1
8MF4 101

3/10

8MF4 380

4/6

8MF4 102

3/10

8MF4 381

4/6

8MF4 106

3/10

8MF4 382

4/6

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens LV 50 2012

9/25

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

8MF4 4

Page

Export markings*
ECCN

AL

8MF4 6

8MF4 400

4/6

8MF4 600

4/9

8MF4 401

4/6

8MF4 601

4/9

8MF4 402

4/6

8MF4 602

4/9

8MF4 403

4/6

8MF4 603

4/9

8MF4 404

4/6

8MF4 604

4/9

8MF4 405

4/6

8MF4 610

4/9

8MF4 406

4/6

8MF4 611

4/9

8MF4 407

4/6

8MF4 612

4/9

8MF4 410

4/6

8MF4 613

4/9

8MF4 411

4/6

8MF4 614

4/9

8MF4 412

4/6

8MF4 620

4/9

8MF4 413

4/6

8MF4 621

4/9

8MF4 414

4/6

8MF4 622

4/9

8MF4 415

4/6

8MF4 623

4/9

8MF4 416

4/6

8MF4 624

4/9

8MF4 417

4/6

8MF4 630

4/9

8MF4 420

4/6

8MF4 631

4/9

8MF4 421

4/6

8MF4 632

4/9

8MF4 422

4/6

8MF4 633

4/9

8MF4 423

4/6

8MF4 634

4/9

8MF4 424

4/6

8MF4 640

4/9

8MF4 425

4/6

8MF4 641

4/9

8MF4 426

4/6

8MF4 642

4/9

8MF4 427

4/6

8MF4 643

4/9

8MF4 5

8MF4 644

4/9

8MF4 500

8MF4 660

4/9

8MF4 661

4/9

8MF4 662

4/9

8MF4 663

4/9

8MF4 664

4/9

4/9

8MF4 501
8MF4 502
8MF4 503
8MF4 504

Order No.

4/8
4/8
4/8
4/8
4/8

N
N
N
N
N

8MF4 510

4/8

8MF4 670

8MF4 511

4/8

8MF4 671

4/9

8MF4 512

4/8

8MF4 672

4/9

8MF4 513

4/8

8MF4 673

4/9

8MF4 514

4/8

8MF4 674

4/9

8MF4 520

4/8

8MF4 680

4/9

8MF4 521

4/8

8MF4 681

4/9

8MF4 522

4/8

8MF4 682

4/9

8MF4 523

4/8

8MF4 683

4/9

8MF4 524

4/8

8MF4 684

4/9

8MF4 530

4/8

8MF4 7

8MF4 550

4/10

8MF4 700

4/10

8MF4 551

4/10

8MF4 701

4/10

8MF4 552

4/10

8MF4 702

4/10

8MF4 555

4/10

8MF4 703

4/10

8MF4 556

4/10

8MF4 704

4/10

8MF4 557

4/10

8MF4 710

4/10

8MF4 560

4/10

8MF4 711

4/10

8MF4 561

4/10

8MF4 712

4/10

8MF4 562

4/10

8MF4 713

4/10

8MF4 570

4/11

8MF4 714

4/10

8MF4 720

4/10

9/26

Siemens LV 50 2012

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

Order No.

Page

Export markings*
ECCN

AL

8MF4 721

4/10

8MF4 882

4/12

8MF4 722

4/10

8MF4 883

4/12

8MF4 723

4/10

8MF4 885

4/13

8MF4 724

4/10

8MF4 886

4/12

8MF4 887

4/12

8MF4 8
8MF4 800

4/4

8MF4 888

4/12

8MF4 801

4/4

8MF4 890

4/15, 7/4

8MF4 802

4/4

8MF4 891

4/15

8MF4 805

4/4

8MF4 892

4/15

8MF4 806

4/4

8MF4 893

4/15

8MF4 807

4/4

8MF4 894

4/12

8MF4 810

4/4

8MF4 895

4/12

8MF4 811

4/4

8MF4 896

4/12

8MF4 812

4/4

8MF4 897

4/12

8MF4 815

4/4

8MF4 898

4/12

8MF4 816

4/4

8MF4 9

8MF4 817

4/4

8MF4 900

7/3

8MF4 820

4/12

8MF4 900-1A

7/3

8MF4 821

4/12

8MF4 900-1B

7/3

8MF4 822

4/12

8MF4 900-1BB

7/3

8MF4 823

4/13

8MF4 901

7/3

8MF4 824

4/13

8MF4 902

7/3

8MF4 825

4/13

8MF4 903

7/4

8MF4 826

4/14

8MF4 904

7/3

8MF4 827

4/14

8MF4 905

7/3

8MF4 828

4/14

8MF4 906

7/3

8MF4 831

4/14

8MF4 908

7/3

8MF4 832

4/14

8MF4 910

4/16

8MF4 833

4/14

8MF4 911

4/16

8MF4 834

4/14

8MF4 912

4/16

8MF4 835

4/14

8MF4 913

4/16

8MF4 836

4/14

8MF4 914

4/16

8MF4 837

4/14

8MF4 915

4/16

8MF4 838

4/14

8MF4 916

4/16

8MF4 840

4/4

8MF4 922

4/7

8MF4 841

4/4

8MF4 923

4/7

8MF4 842

4/4

8MF4 924

4/7

8MF4 845

4/4

8MF4 925

4/7

8MF4 846

4/4

8MF4 926

4/7

8MF4 847

4/4

8MF4 932

4/7

8MF4 850

4/4

8MF4 933

4/7

8MF4 851

4/4

8MF4 934

4/7

8MF4 852

4/4

8MF4 935

4/7

8MF4 855

4/4

8MF4 936

4/7

8MF4 856

4/4

8MF4 942

4/16

8MF4 857

4/4

8MF4 943

4/16

8MF4 860

4/5

8MF4 944

4/16

8MF4 861

4/5

8MF4 945

4/16

8MF4 870

4/12

8MF4 946

4/16

8MF4 871

4/12

8MF4 872

4/12

8MF4 880

4/12

8MF4 881

4/12

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens LV 50 2012

9/27

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*

Order No.

Page

ECCN

AL

8MF5 0

8MF5 098-4R

2/6

8MF5 024-4E

2/6

8MF5 098-5E

5/7

8MF5 024-4R

2/6

8MF5 098-5R

5/7

8MF5 024-5E

5/7

8MF5 2

8MF5 024-5R

5/7

8MF5 224-4E

2/6

8MF5 026-4E

2/6

8MF5 224-4R

2/6

8MF5 026-4R

2/6

8MF5 224-5E

5/7

8MF5 026-5E

5/7

8MF5 224-5R

5/7

8MF5 026-5R

5/7

8MF5 226-4E

2/6

8MF5 028-4E

2/6

8MF5 226-4R

2/6

8MF5 028-4R

2/6

8MF5 226-5E

5/7

8MF5 028-5E

5/7

8MF5 226-5R

5/7

8MF5 028-5R

5/7

8MF5 228-4E

2/6

8MF5 064-4E

2/6

8MF5 228-4R

2/6

8MF5 064-4ES

5/10

8MF5 228-5E

5/7

8MF5 064-4R

2/6

8MF5 228-5R

5/7

8MF5 064-5E

5/7

8MF5 264-4E

2/6

8MF5 064-5R

5/7

8MF5 264-4ES

5/10

8MF5 066-4E

2/6

8MF5 264-4R

2/6

8MF5 066-4ES

5/10

8MF5 264-5E

5/7

8MF5 066-4R

2/6

8MF5 264-5R

5/7

8MF5 066-5E

5/7

8MF5 266-4E

2/6

8MF5 066-5R

5/7

8MF5 266-4ES

5/10

8MF5 068-4E

2/6

8MF5 266-4R

2/6

8MF5 068-4ES

5/10

8MF5 266-5E

5/7

8MF5 068-4R

2/6

8MF5 266-5R

5/7

8MF5 068-5E

5/7

8MF5 268-4E

2/6

8MF5 068-5R

5/7

8MF5 268-4ES

5/10

8MF5 084-4E

2/6

8MF5 268-4R

2/6

8MF5 084-4ES

5/10

8MF5 268-5E

5/7

8MF5 084-4R

2/6

8MF5 268-5R

5/7

8MF5 084-5E

5/7

8MF5 284-4E

2/6

8MF5 084-5R

5/7

8MF5 284-4ES

5/10

8MF5 086-4E

2/6

8MF5 284-4R

2/6

8MF5 086-4ES

5/10

8MF5 284-5E

5/7

8MF5 086-4R

2/6

8MF5 284-5R

5/7

8MF5 086-5E

5/7

8MF5 286-4E

2/6

8MF5 086-5R

5/7

8MF5 286-4ES

5/10

8MF5 088-4E

2/6

8MF5 286-4R

2/6

8MF5 088-4R

2/6

8MF5 286-5E

5/7

8MF5 088-5E

5/7

8MF5 286-5R

5/7

8MF5 088-5R

5/7

8MF5 288-4E

2/6

8MF5 094-4E

2/6

8MF5 288-4R

2/6

8MF5 094-4ES

5/10

8MF5 288-5E

5/7

8MF5 094-4R

2/6

8MF5 288-5R

5/7

8MF5 094-5E

5/7

8MF5 294-4E

2/6

8MF5 094-5R

5/7

8MF5 294-4ES

5/10

8MF5 096-4E

2/6

8MF5 294-4R

2/6

8MF5 096-4ES

5/10

8MF5 294-5E

5/7

8MF5 096-4R

2/6

8MF5 294-5R

5/7

8MF5 096-5E

5/7

8MF5 296-4E

2/6

8MF5 096-5R

5/7

8MF5 296-4ES

5/10

8MF5 098-4E

2/6

8MF5 296-4R

2/6

ECCN

9/28

Siemens LV 50 2012

AL

Export markings*

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

Order No.

Page

Export markings*
ECCN

AL

8MF5 296-5E

5/7

8MF5 896-4E

2/6

8MF5 296-5R

5/7

8MF5 896-4ES

5/10

8MF5 298-4E

2/6

8MF5 896-4R

2/6

8MF5 298-4R

2/6

8MF5 896-5E

5/7

8MF5 298-5E

5/7

8MF5 896-5R

5/7

8MF5 298-5R

5/7

8MF5 898-4E

2/6

8MF5 898-4R

2/6

8MF5 8
8MF5 824-4E

2/6

8MF5 898-5E

5/7

8MF5 824-4R

2/6

8MF5 898-5R

5/7

8MF5 824-5E

5/7

8MF5 9

8MF5 824-5R

5/7

8MF5 900

7/3

8MF5 826-4E

2/6

8MF5 900-1A

7/3

8MF5 826-4R

2/6

8MF5 900-1B

7/3

8MF5 826-5E

5/7

8MF5 900-1C

7/3

8MF5 826-5R

5/7

8MF5 900-2A

7/3

8MF5 828-4E

2/6

8MF5 900-2B

7/3

8MF5 828-4R

2/6

8MF5 900-3A

7/3

8MF5 828-5E

5/7

8MF5 900-3B

7/3

8MF5 828-5R

5/7

8MF5 910

7/3

8MF5 864-4E

2/6

8MF5 910-1A

7/3

8MF5 864-4ES

5/10

8MF5 910-1B

7/3

8MF5 864-4R

2/6

8MF5 910-1C

7/3

8MF5 864-5E

5/7

8MF5 910-2A

7/3

8MF5 864-5R

5/7

8MF5 910-2B

7/3

8MF5 866-4E

2/6

8MF5 910-3A

7/3

8MF5 866-4ES

5/10

8MF5 910-3B

7/3

8MF5 866-4R

2/6

8MF6 0

8MF5 866-5E

5/7

8MF6 024-4E

2/7

8MF5 866-5R

5/7

8MF6 024-4R

2/7

8MF5 868-4E

2/6

8MF6 024-5E

5/8

8MF5 868-4ES

5/10

8MF6 024-5R

5/8

8MF5 868-4R

2/6

8MF6 026-4E

2/7

8MF5 868-5E

5/7

8MF6 026-4R

2/7

8MF5 868-5R

5/7

8MF6 026-5E

5/8

8MF5 884-4E

2/6

8MF6 026-5R

5/8

8MF5 884-4ES

5/10

8MF6 028-4E

2/7

8MF5 884-4R

2/6

8MF6 028-4R

2/7

8MF5 884-5E

5/7

8MF6 028-5E

5/8

8MF5 884-5R

5/7

8MF6 028-5R

5/8

8MF5 886-4E

2/6

8MF6 064-4E

2/7

8MF5 886-4ES

5/10

8MF6 064-4ES

5/10

8MF5 886-4R

2/6

8MF6 064-4R

2/7

8MF5 886-5E

5/7

8MF6 064-5E

5/8

8MF5 886-5R

5/7

8MF6 064-5R

5/8

8MF5 888-4E

2/6

8MF6 066-4E

2/7

8MF5 888-4R

2/6

8MF6 066-4ES

5/10

8MF5 888-5E

5/7

8MF6 066-4R

2/7

8MF5 888-5R

5/7

8MF6 066-5E

5/8

8MF5 894-4E

2/6

8MF6 066-5R

5/8

8MF5 894-4ES

5/10

8MF6 068-4E

2/7

8MF5 894-4R

2/6

8MF6 068-4ES

5/10

8MF5 894-5E

5/7

8MF6 068-4R

2/7

8MF5 894-5R

5/7

8MF6 068-5E

5/8

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens LV 50 2012

9/29

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

Page

Export markings*
ECCN

AL

8MF6 068-5R

5/8

8MF6 266-5R

5/8

8MF6 084-4E

2/7

8MF6 268-4E

2/7

8MF6 084-4ES

5/10

8MF6 268-4ES

5/10

8MF6 084-4R

2/7

8MF6 268-4R

2/7

8MF6 084-5E

5/8

8MF6 268-5E

5/8

8MF6 084-5R

5/8

8MF6 268-5R

5/8

8MF6 086-4E

2/7

8MF6 284-4E

2/7

8MF6 086-4ES

5/10

8MF6 284-4ES

5/10

8MF6 086-4R

2/7

8MF6 284-4R

2/7

8MF6 086-5E

5/8

8MF6 284-5E

5/8

8MF6 086-5R

5/8

8MF6 284-5R

5/8

8MF6 088-4E

2/7

8MF6 286-4E

2/7

8MF6 088-4R

2/7

8MF6 286-4ES

5/10

8MF6 088-5E

5/8

8MF6 286-4R

2/7

8MF6 088-5R

5/8

8MF6 286-5E

5/8

8MF6 094-4E

2/7

8MF6 286-5R

5/8

8MF6 094-4ES

5/10

8MF6 288-4E

2/7

8MF6 094-4R

2/7

8MF6 288-4R

2/7

8MF6 094-5E

5/8

8MF6 288-5E

5/8

8MF6 094-5R

5/8

8MF6 288-5R

5/8

8MF6 096-4E

2/7

8MF6 294-4E

2/7

8MF6 096-4ES

5/10

8MF6 294-4ES

5/10

8MF6 096-4R

2/7

8MF6 294-4R

2/7

8MF6 096-5E

5/8

8MF6 294-5E

5/8

8MF6 096-5R

5/8

8MF6 294-5R

5/8

8MF6 098-4E

2/7

8MF6 296-4E

2/7

8MF6 098-4R

2/7

8MF6 296-4ES

5/10

8MF6 098-5E

5/8

8MF6 296-4KE

5/13

8MF6 098-5R

5/8

8MF6 296-4R

2/7

8MF6 296-5E

5/8

8MF6 2
8MF6 224-4E

2/7

8MF6 296-5KE

5/13

8MF6 224-4R

2/7

8MF6 296-5R

5/8

8MF6 298-4E

2/7

8MF6 298-4R

2/7

8MF6 298-5E

5/8

8MF6 298-5R

5/8

8MF6 224-5E

5/8
5/8

8MF6 224-5R
8MF6 226-4E

Order No.

2/7

N
N
N

8MF6 226-4R

2/7

8MF6 226-5E

5/8

8MF6 8

8MF6 226-5R

5/8

8MF6 824-4E

2/7

8MF6 228-4E

2/7

8MF6 824-4R

2/7

8MF6 228-4R

2/7

8MF6 824-5E

5/8

8MF6 228-5E

5/8

8MF6 824-5R

5/8

8MF6 228-5R

5/8

8MF6 826-4E

2/7

8MF6 264-4E

2/7

8MF6 826-4R

2/7

8MF6 264-4ES

5/10

8MF6 826-5E

5/8

8MF6 264-4R

2/7

8MF6 826-5R

5/8

8MF6 264-5E

5/8

8MF6 828-4E

2/7

8MF6 264-5R

5/8

8MF6 828-4R

2/7

8MF6 266-4E

2/7

8MF6 828-5E

5/8

8MF6 266-4ES

5/10

8MF6 828-5R

5/8

8MF6 266-4KE

5/13

8MF6 864-4E

2/7

8MF6 266-4R

2/7

8MF6 864-4ES

5/10

8MF6 266-5E

5/8

8MF6 864-4R

2/7

8MF6 266-5KE

5/13

8MF6 864-5E

5/8

9/30

Siemens LV 50 2012

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

Order No.

Page

Export markings*
ECCN

AL

8MF6 864-5R

5/8

8MF9 071

3/15

8MF6 866-4E

2/7

8MF9 072

3/15

8MF6 866-4ES

5/10

8MF9 073

3/15

8MF6 866-4R

2/7

8MF9 074

3/15

8MF6 866-5E

5/8

8MF9 081

3/15

8MF6 866-5R

5/8

8MF9 082

3/15

8MF6 868-4E

2/7

8MF9 083

3/15

8MF6 868-4ES

5/10

8MF9 1

8MF6 868-4R

2/7

8MF9 100

2/8

8MF6 868-5E

5/8

8MF9 101

2/8

8MF6 868-5R

5/8

8MF9 113

2/8

8MF6 884-4E

2/7

8MF9 115

2/8

9I999

8MF6 884-4ES

5/10

8MR2 1

8MF6 884-4R

2/7

8MR2 122-4A

8/10

8MF6 884-5E

5/8

8MR2 122-4AB

8/10

8MF6 884-5R

5/8

8MR2 122-4AC

8/10

8MF6 886-4E

2/7

8MR2 122-4B

8/10

8MF6 886-4ES

5/10

8MR2 122-8A

8/10

8MF6 886-4R

2/7

8MR2 122-8B

8/10

8MF6 886-5E

5/8

8MR2 130-0A

8/9

8MF6 886-5R

5/8

8MR2 130-1A

8/9

8MF6 888-4E

2/7

8MR2 130-3A

8/9

8MF6 888-4R

2/7

8MR2 130-4A

8/9

8MF6 888-5E

5/8

8MR2 130-5A

8/9

8MF6 888-5R

5/8

8MR2 130-6A

8/9

8MF6 894-4E

2/7

8MR2 130-7A

8/9

8MF6 894-4ES

5/10

8MR2 131-0A

8/9

8MF6 894-4R

2/7

8MR2 131-4A

8/9

8MF6 894-5E

5/8

8MR2 131-5A

8/9

8MF6 894-5R

5/8

8MR2 132-0A

8/9

8MF6 896-4E

2/7

8MR2 132-0AB

8/9

8MF6 896-4ES

5/10

8MR2 132-1A

8/9

8MF6 896-4R

2/7

8MR2 132-1AB

8/9

8MF6 896-5E

5/8

8MR2 132-5A

8/9

8MF6 896-5R

5/8

8MR2 132-5AB

8/9

8MF6 898-4E

2/7

8MR2 140-0A

8/10

EAR99H

8MF6 898-4R

2/7

8MR2 140-0B

8/10

EAR99H

8MF6 898-5E

5/8

8MR2 140-1A

8/10

EAR99H

8MF6 898-5R

5/8

8MR2 140-1B

8/10

EAR99H

8MR2 140-2A

8/10

EAR99H

8MF8 8
8MF8 806

4/17

9I999

8MR2 140-2B

8/10

8MF8 807

4/17

9I999

8MR2 140-3A

8/10

EAR99H

8MF8 810

4/17

9I999

8MR2 140-3B

8/10

EAR99

8MR2 140-3C

8/11

8MF9 0
8MF9 052

3/15

8MR2 140-3D

8/11

8MF9 055

3/15

8MR2 140-4A

8/10

EAR99H

8MF9 056

3/15

8MR2 140-4B

8/10

8MF9 060

3/15

8MR2 140-5C

8/11

8MF9 061

3/15

8MR2 140-5D

8/11

8MF9 062

3/15

8MR2 140-6C

8/10

8MF9 065

3/15

8MR2 140-6D

8/10

8MF9 066

3/15

8MR2 150-0A

8/10

8MF9 070

3/15

8MR2 150-0BA

8/10

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens LV 50 2012

9/31

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

8MR6 400-5GV45

8/5

8MR2 150-0CA

8/10

8MR6 400-5GV67

8/5

8MR2 150-2A

8/11

8MR6 400-6GV30

8/5

8MR2 150-2B

8/11

8MR6 400-6GV45

8/5

8MR2 150-2C

8/11

8MR6 402-2LV41

8/4

8MR2 150-2D

8/11

8MR6 411-5LV10

8/4

8MR2 150-3A

8/11

8MR6 411-5LV25

8/4

8MR2 150-3B

8/11

8MR6 411-5LV30

8/4

8MR2 170-1A

8/13

8MR6 411-5LV41

8/4

8MR2 170-1AF

8/13

8MR6 411-5LV45

8/4

8MR2 170-1B

8/13

8MR6 411-5LV60

8/4

8MR2 170-1C

8/13

8MR6 411-5LV80

8/4

8MR2 170-1CA

8/12

8MR6 411-6LV30

8/5

8MR2 170-1CB

8/12

8MR6 411-6LV41

8/5

8MR2 170-1DA

8/12

8MR6 411-6LV45

8/5

8MR2 170-1DB

8/12

8MR6 423-2LV10

8/4

8MR2 170-1E

8/13

8MR6 423-2LV25

8/4

8MR2 170-2A

8/13

8MR6 423-2LV41

8/4

8MR2 170-2BA

8/12

8MR6 423-2LV45

8/4

8MR2 170-2BB

8/12

8MR6 423-2LV60

8/4

8MR2 170-4E

8/14

8MR6 423-5DE04

8/7

8MR2 170-4F

8/14

8MR6 423-5DE08

8/7

8MR2 170-4H

8/14

8MR6 423-5DE12

8/7

8MR2 171-1BA

8/12

8MR6 423-5DE15

8/7

8MR2 171-1BB

8/12

8MR6 423-5DE20

8/7

8MR2 171-2BA

8/12

8MR6 423-5EG04

8/7

8MR2 171-2BB

8/12

8MR6 423-5EG06

8/7

8MR2 172-1A

8/13

8MR6 423-5EG08

8/7

8MR2 172-1AB

8/13

8MR6 423-5LV10

8/4

8MR2 172-2A

8/13

8MR6 423-5LV25

8/4

8MR2 180-1A

8/14

8MR6 423-5LV30

8/4

8MR2 180-1B

8/14

8MR6 423-5LV41

8/4

8MR2 190-1A

8/6

8MR6 423-5LV45

8/4

8MR6 0

8MR6 423-5LV60

8/4

8MR6 000-0AM10

8MR6 423-5LV80

8/4

8MR6 423-5ML36

8/8

8MR6 423-5ML80

8/8

8MR6 423-5SK10

8/7

8MR6 423-5SK15

8/7

8MR6 423-5SK20

8/7

8MR6 3

8MR6 423-6LV30

8/5

8MR6 311-5DL40

8/6

8MR6 423-6LV41

8/5

8MR6 311-5DL42

8/6

8MR6 423-6LV45

8/5

8MR6 323-5DL40

8/6

8MR6 440-5DE30

8/7

8MR6 323-5DL42

8/6

8MR6 440-5DE40

8/7

8MR6 440-5EG30

8/7

8MR6 000-0AM30
8MR6 000-0AM45
8MR6 000-0AM67
8MR6 000-5DE40

8/6
8/6
8/6
8/6
8/6

AL

Page

8/10

8/6

ECCN

Order No.

8MR2 150-0C

8MR6 000-0AM25

Export markings*

N
N
N
N
N
N

8MR6 4
8MR6 400-2GV10

8/5

8MR6 440-5EG40

8/7

8MR6 400-2GV25

8/5

8MR6 440-5EG60

8/7

8MR6 400-2GV45

8/5

8MR6 5

8MR6 400-2GV67

8/5

8MR6 500-5GV25

8/5

8MR6 400-5GV10

8/5

8MR6 500-5GV30

8/5

8MR6 400-5GV25

8/5

8MR6 500-5GV45

8/5

8MR6 500-5GV67

8/5

8MR6 400-5GV30

9/32

8/5

Siemens LV 50 2012

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens AG 2012

Appendix
Order No. index
including Export markings
Order No.

Page

Export markings*
ECCN

AL

8MR6 500-6GV30

8/5

8MR6 500-6GV45

8/5

8MR6 511-5LV25

8/4

8MR6 511-5LV30

8/4

8MR6 511-5LV41

8/4

8MR6 511-5LV45

8/4

8MR6 511-5LV60

8/4

8MR6 511-5LV80

8/4

8MR6 511-6LV30

8/5

8MR6 511-6LV41

8/5

8MR6 511-6LV45

8/5

8MR6 523-5LV25

8/4

8MR6 523-5LV30

8/4

8MR6 523-5LV45

8/4

8MR6 523-5LV60

8/4

8MR6 523-5LV80

8/4

8MR6 523-6LV30

8/5

8MR6 523-6LV41

8/5

8MR6 523-6LV45

8/5

*A product's export markings are updated daily at www.siemens.com/industrymall.

Siemens LV 50 2012

9/33

Siemens AG 2012

Appendix
Conditions of sale and delivery

Overview

Export regulations

By using this catalog you can acquire hardware and software


products described therein from Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by
any Siemens entity having a registered office outside of Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following terms apply exclusively for orders placed with Siemens AG.
For customers with a seat or registered office in Germany
The General Terms of Payment as well as the General Conditions for the Supply of Products and Services of the Electrical
and Electronics Industry shall apply.
For software products, the General License Conditions for Software Products for Automation and Drives for Customers with a
Seat or registered Office in Germany shall apply.
For customers with a seat or registered office outside of
Germany
The General Terms of Payment as well as the General Conditions for Supplies of Siemens, Automation and Drives for Customers with a Seat or registered Office outside of Germany shall
apply.
For software products, the General License Conditions for Software Products for Automation and Drives for Customers with a
Seat or registered Office outside of Germany shall apply.

General
The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches only
apply to devices for export.
Illustrations are not binding.
Insofar as there are no remarks on the corresponding pages,
- especially with regard to data, dimensions and weights given these are subject to change without prior notice.
The prices are in (Euro) ex works, exclusive packaging.
The sales tax (value added tax) is not included in the prices.
It shall be debited separately at the respective rate according to
the applicable legal regulations.
Prices are subject to change without prior notice. We will debit
the prices valid at the time of delivery.
Surcharges will be added to the prices of products that contain
silver, copper, aluminum, lead and/or gold if the respective basic official prices for these metals are exceeded. These surcharges will be determined based on the official price and the metal
factor of the respective product.
The surcharge will be calculated on the basis of the official price
on the day prior to receipt of the order or prior to the release
order.
The metal factor determines the official price as of which the metal surcharges are charged and the calculation method used.
The metal factor, provided it is relevant, is included with the
price information of the respective products.
You will find
an exact explanation of the metal factor,
the text of the Comprehensive Terms and Conditions of Sale
and Delivery of Siemens AG
in the Internet under
www.siemens.com/automation/salesmaterial-as/catalog/en
/terms_of_trade_en.pdf

9/34

Siemens LV 50 2012

Siemens shall not be obligated to fulfill this agreement if such fulfillment is prevented by any impediments arising out of national
or international foreign trade or customs requirements or any
embargoes or other sanctions.
If Purchaser transfers goods (hardware and/ or software and/ or
technology as well as corresponding documentation, regardless
of the mode of provision) delivered by Siemens or works and
services (including all kinds of technical support) performed by
Siemens to a third party worldwide, Purchaser shall comply with
all applicable national and international (re-) export control regulations. In any event Purchaser shall comply with the (re-) export
control regulations of the Federal Republic of Germany, of the
European Union and of the United States of America.
If required to conduct export control checks, Purchaser, upon
request by Siemens, shall promptly provide Siemens with all information pertaining to particular end customer, destination and
intended use of goods, works and services provided by Siemens, as well as any export control restrictions existing.
Purchaser shall indemnify and hold harmless Siemens from and
against any claim, proceeding, action, fine, loss, cost and damages arising out of or relating to any noncompliance with export
control regulations by Purchaser, and Purchaser shall compensate Siemens for all losses and expenses resulting thereof, unless such noncompliance was not caused by fault of the
Purchaser. This provision does not imply a change in burden of
proof.
The products listed in this catalog / price list may be subject to
European / German and/or US export regulations.
Therefore, any export requiring a license is subject to approval
by the competent authorities.
According to current provisions, the following export regulations
must be observed with respect to the products featured in this
catalog / price list:
AL

Number of the German Export List


Products marked other than N require an export license.
In the case of software products, the export designations of the
relevant data medium must also be generally adhered to.
Goods labeled with an AL not equal to N are subject to European or German export authorization when being exported
out of the EU.

ECCN

Export Control Classification Number


Products marked other than N are subject to a reexport license to specific countries.
In the case of software products, the export designations of the
relevant data medium must also be generally adhered to.
Goods labeled with ECCN not equal to N are subject to US
re-export authorization.

Even without a label, or with label "AL:N" or "ECCN:N", authorization may be required due to the final end-use and destination for
which the goods are to be used.
In addition, you can preview the export designations via our "Industry Mall" online catalog system in the respective product description. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices.
Errors excepted and subject to change without prior notice.

Siemens AG 2012

Catalogs
Industry Automation, Drive Technologies and Low-Voltage Power Distribution
Further information can be obtained from our branch offices
listed at www.siemens.com/automation/partner
Interactive Catalog on DVD
for Industry Automation, Drive Technologies and
Low Voltage Distribution
Drive Systems
Variable-Speed Drives
SINAMICS G130 Drive Converter Chassis Units
SINAMICS G150 Drive Converter Cabinet Units
SINAMICS GM150, SINAMICS SM150
Medium-Voltage Converters
ROBICON Perfect Harmony
Medium-Voltage Air-Cooled Drives
Germany Edition
SINAMICS S120 Chassis Format Units and
Cabinet Modules
SINAMICS S150 Converter Cabinet Units
SINAMICS DCM Converter Units
SINAMICS and Motors for Single-Axis Drives

Catalog
CA 01

D 11
D 12
D 15.1

Catalog
D 31
NC 60
NC 61
NC 81.1
NC 82
PM 21
CR 1

D 21.3

D 23.1
D 31

Three-phase Induction Motors


H-compact
H-compact PLUS

D 84.1

Asynchronous Motors Standardline


Synchronous Motors with Permanent-Magnet
Technology, HT-direct
DC Motors
SIMOREG DC MASTER 6RA70 Digital Chassis
Converters
SIMOREG K 6RA22 Analog Chassis Converters
PDF: SIMOREG DC MASTER 6RM70 Digital Converter
Cabinet Units
SIMOVERT PM Modular Converter Systems
SIEMOSYN Motors
MICROMASTER 420/430/440 Inverters
MICROMASTER 411/COMBIMASTER 411
SIMOVERT MASTERDRIVES Vector Control
SIMOVERT MASTERDRIVES Motion Control
Synchronous and asynchronous servomotors for
SIMOVERT MASTERDRIVES
SIMODRIVE 611 universal and POSMO
SIMOTION, SINAMICS S120 and
Motors for Production Machines
SINUMERIK, SIMODRIVE and
Motors for Machine Tools
SINUMERIK, SINAMICS S120 and
Motors for Machine Tools

D 86.1
D 86.2
DA 12
DA 21.1
DA 21.2
DA 22
DA 45
DA 48
DA 51.2
DA 51.3
DA 65.10
DA 65.11
DA 65.3
DA 65.4
PM 21
NC 60
NC 61

Low-Voltage Three-Phase-Motors
SIMOTICS Low-Voltage Motors
MOTOX Geared Motors
SIMOGEAR Geared Motors

D 81.1
D 87.1
MD 50.1

Mechanical Driving Machines


FLENDER Standard Couplings
FLENDER SIG Standard industrial gear unit
FLENDER SIP Standard industrial planetary gear units

MD 10.1
MD 30.1
MD 31.1

Low-Voltage Power Distribution and


Electrical Installation Technology
SENTRON Protection, Switching, Measuring and
Monitoring Devices
SIVACON ALPHA Switchboards and Distribution
Systems
SIVACON 8PS Busbar Trunking Systems
GAMMA Building Control
PDF: DELTA Switches and Socket Outlets

Motion Control
SINAMICS and Motors for Single-Axis Drives
SINUMERIK & SIMODRIVE
Automation Systems for Machine Tools
SINUMERIK & SINAMICS
Equipment for Machine Tools
SINUMERIK 808D, SINAMICS V60 and G120
and SIMOTICS 1FL5 and 1LE1 motors
SINUMERIK 828D BASIC T/BASIC M,
SINAMICS S120 Combi and 1FK7/1PH8 motors
SIMOTION, SINAMICS S120 and
Motors for Production Machines
Drive and Control Components for Cranes
Power Supply and System Cabling
Power supply SITOP
System cabling SIMATIC TOP connect
Process Instrumentation and Analytics
Field Instruments for Process Automation
SIREC Recorders and Accessories
SIPART, Controllers and Software
Products for Weighing Technology
PDF: Process Analytical Instruments
PDF: Process Analytics,
Components for the System Integration

FI 01
MP 20
MP 31
WT 10
PA 01
PA 11

Safety Integrated
Safety Technology for Factory Automation

SI 10

SIMATIC HMI/PC-based Automation


Human Machine Interface Systems/
PC-based Automation

ST 80/
ST PC

SIMATIC Ident
Industrial Identification Systems

ID 10

SIMATIC Industrial Automation Systems


Products for Totally Integrated Automation and
Micro Automation
SIMATIC PCS 7 Process Control System
Add-ons for the SIMATIC PCS 7
Process Control System
PDF: Migration solutions with the SIMATIC PCS 7
Process Control System
SIMATIC NET
Industrial Communication

ST 70
ST PCS 7
ST PCS 7.1
ST PCS 7.2

IK PI

SINVERT Photovoltaics
Inverters and Components for Photovoltaic Installations RE 10

LV 10.2

SIRIUS Industrial Controls


SIRIUS Industrial Controls
SIRIUS Industrial Controls
(selected content from catalog IC 10)

LV 70
ET G1
ET D1

System Solutions
Applications and Products for Industry are part of the
interactive catalog CA 01

LV 10.1

KT 10.1
KT 10.2

IC 10
IC 90

Information and Download Center


PDF: These catalogs are only available as pdf files.

PDF versions of the catalogs are available on the Internet at:


www.siemens.com/lowvoltage/infomaterial

Siemens AG 2012

Siemens AG
Infrastructure & Cities Sector
Low and Medium Voltage Division
Low Voltage Distribution
Postfach 10 09 53
93009 REGENSBURG
GERMANY

www.siemens.com/lowvoltage

Subject to change without prior notice


PDF only (E86060-K1920-A101-A5-7600)
MP.R3.LV.0000.00.2.39
KG 0912 126 En
Siemens AG 2012

The information provided in this catalog contains descriptions or


characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of further
development of the products. An obligation to provide
the respective characteristics shall only exist if expressly agreed in
the terms of contract. Availability and technical specifications are
subject to change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third
parties for their own purposes could violate the rights of
the owners.

Вам также может понравиться