IDM 7600-S

AIRFIELD LIGHTING CONTROL


AND MONITORING SYSTEM

CONTROL MANUAL
DEMO
INTERNATIONAL AIRPORT

IDM 7600-S- Control Manual - DEMO

Revision index
Revision:

Author:

Date:

Checked:

Description

01

J.Karttunen

23.06.2008

JK

1st release

Other control system and related manuals


Manual:

Description

Installation manual
CCR manuals

Installation, maintenance and troubleshooting


Manuals for CCR and other devices connected with the system

General symbols used in the manuals:


Symbol

Description

Provides additional information of the subject


Note

Special attention with the information is required


Caution

Not obeying this information may risk flight or personal safety


Warning

This manual is property of Philips Oy Airfield lighting


Copying in any form or transmitting to a third party without owners written consent violates
copyright laws and is forbidden!

PHILIPS OY
Airfield lighting
Kisllintie 6
FI-01730 Vantaa
Finland
Telephone
Telefax
e-mail

+358 9 61 392 11
+358 9 61 392 500
forename.familyname@philips.com

IDMAN PHILIPS

2 / 16

IDM 7600-S- Control Manual - DEMO

Contents
page
1 GENERAL .............................................................................................................................. 4
1.1
Scope of the manual .................................................................................................... 4
1.2
Control station hardware .............................................................................................. 4
1.3
Control conditions......................................................................................................... 4
1.4
Control modes .............................................................................................................. 4
1.5
Backlight control ........................................................................................................... 4
1.6
Screen adjustments...................................................................................................... 4
1.7
Control button activity indication .................................................................................. 4
1.8
Application page arrangement ..................................................................................... 5
2 BASIC CONTROL PROCEDURES ....................................................................................... 6
2.1
Runway controls........................................................................................................... 6
2.2
Taxiway controls with Com (common intensity) selection............................................ 6
3 CONTROL PAGES ................................................................................................................ 7
3.1
Main page..................................................................................................................... 7
3.1.1
Mimic indications...................................................................................................... 7
3.1.2
Runway controls ...................................................................................................... 8
3.1.3
Taxiway and auxiliary controls................................................................................. 9
3.2
Auxiliary pop up panels .............................................................................................. 10
3.2.1
Runway direct keyboard ........................................................................................ 10
3.2.2
Monitoring panel (optional) .................................................................................... 11
3.2.3
Adjustment panel ................................................................................................... 12
3.2.4
Settings panels ...................................................................................................... 13
4 APPENDIXES ...................................................................................................................... 16
4.1
Appendix 1: Detailed fault definitions ......................................................................... 16

IDMAN PHILIPS

3 / 16

IDM 7600-S- Control Manual - DEMO

1
1.1

GENERAL
Scope of the manual

This manual describes the control interface of the system and is purposed for air traffic
controllers and other personnel who need to control the airfield lighting system.
1.2

Control station hardware

The control station is a 7,5 TFT LCD touchscreen unit


1.3

Control conditions

In order to control the station must be online with the controls system (i.e. the PLC)
1.4

Control modes

Control mode for each control class (direction, runway controls, taxiway common etc) can
be selected from the settings / control settings panel (password protected).
Selections: no confirmation / confirm off / confirm all are available.
When confirmation is required and a control button is selected a confirmation
panel opens where the control can be either confirmed or cancelled.
1.5

Backlight control

From the screen adjustment page backlight off mode which turns the screens backlight
off can be selected. The off-mode is useful when the unit is not used for longer period to
save energy and to increase the lifetime of the unit. Confirmation window opens when
entering the off-mode. Return to normal mode is made by touching anywhere on the
screen.
1.6

Screen adjustments

From the screen adjustment panel the background colour can be selected from light grey to
black in eight grades. Also screen brilliancy adjustment with 16 levels and indicator is
provided.
1.7

Control button activity indication

As systems may not be available for both landing directions the control buttons are
provided with activity indication which tells which controls are available for the selected
direction.
Active : button colour light grey or coloured (not dark grey)
Passive: button colour dark grey
Also control buttons may have been included for future extensions to be activated later

IDMAN PHILIPS

4 / 16

IDM 7600-S- Control Manual - DEMO

1.8

Application page arrangement

The application consists of main page with footer taskbar and several auxiliary pop up
panels to assist control and monitoring tasks. The main page is divided into two sections:
1. Main display area with main controls and mimic diagram

Auxiliary pop up panels appear on top of the screen (replaces the mimic diagram) and
runway direct keyboard replaces the runway inc/dec keyboard when selected

2. Footer taskbar

Alive

Online
Language selection

On the left corner (top) alive indicator which confirm that this control
stations application is running (alive box is rolling).
On the left corner (top) online indicator which confirm that this
control station is connected with the system
Select user interface language from the national flag buttons.
Two languages are available: local / English
?-button opens a help page.

Help

Aux panel selection

Alarm

On the right side set of auxiliary pop up panel buttons.


Selecting a button opens the panel and selecting an active panel button
closes it. Yellow-bar Indicator confirms which panels are open.
Password is required to open the settings panel

When a new fault occurs the alarm buzzer sounds and the reset button
will be red. The button remains red as long as there any faults in the
system. There are three types of faults:
Control faults: buzzer sounds and the reset-button turns red. Failed
controls can be identified from the control buttons and mimic
diagram.
Panel offline alarms: only alarm buzzer sounds. Failure is indicated
with the online-indication (turns red)
DC-UPS alarm: buzzer sounds and the reset-button turns red.
Status can be checked from the monitoring page (optional).
Select the reset button to silence the alarm buzzer

IDMAN PHILIPS

5 / 16

IDM 7600-S- Control Manual - DEMO

BASIC CONTROL PROCEDURES

2.1

Runway controls
Step

Buttons

Action

Select operation direction, the lights turn now on.

Adjust individual controls with direct or inc/dec controls if needed

Select direction off when the operation is finished, the lights turn off

2.2

Taxiway controls with Com (common intensity) selection


Step

Buttons

Action

Select desired Com intensity according prevailing conditions

2
3

Select desired segments: the lights now turn on


Setting Com to off turns off all lights, but the segments remain selected

Selecting Com intensity again turns on all lights on selected segments

IDMAN PHILIPS

6 / 16

IDM 7600-S- Control Manual - DEMO

3
3.1

CONTROL PAGES
Main page

The page includes the mimic for the lighting system, runway direction and brilliancy
controls and taxiway common intensity controls.
Taxiway segment and auxiliary controls can be done directly from the mimic diagram
Auxiliary pop up panels can be opened to assist the control and monitoring tasks.

Fig 1 Main page


3.1.1

Mimic indications

Mimic indications:

Displays selected direction (=green text)


Direction indication
Mimic symbol
Unidirectional light
Mimic symbol
Omnidirectional light

Circuit (CCR) status indication:


Grey = control and CCR off
Coloured = control on and CCR is on controlled step
Blink = CCR is not on controlled step
Colours according the colours of the actual lights

IDMAN PHILIPS

7 / 16

IDM 7600-S- Control Manual - DEMO

3.1.2

Runway controls

Runway controls

Operation direction control:


Control:

New selection replaces any prior direction selection


Confirmation may be needed depending on the confirmation setting
Rwy Off turns off all runway lights!
Indication:
Direction

Button colour:
White (off) / green : selected
Grey : Not selected
Individual runway control with step / status indication.
Control:

Up- button increases the control with one step


Down button decreases the control with one step
Confirmation may be needed depending on the confirmation setting
Indication:

Runway
Inc / dec control

Button colour:
Dark grey: Control is passive (no devices configured or dir=off)
Grey : Control is active
Step indicator text and background colour:
Dark grey: Control is passive
Off / white: Control =off and lights 100% available (1)
Off / white / slow blink: Control=off, lights less than 100% available
Off / white / fast blink: Control=off, lights less than 50% available
0,1%..100% / yellow: Control=0,1%..100%, performance 100% (2)
0,1%..100% / yellow / slow blink: Control=0,1%..100%,
performance less than 100%.
0,1%...100% / Yellow / fast blink: Control=0,1%...100%,
performance less than 50%.

(1) Light availability means that the CCRs (constant current regulators, feeding the lights)are powered,
online and in remote control mode i.e. available for controls
(2) Performance means that the system (i.e. CCRs) is working with desired control step, CCRs output
currents are correct, lamp fault and VA-status are OK. Naturally this depends on the monitoring functions
provided by the CCRs.

IDMAN PHILIPS

8 / 16

IDM 7600-S- Control Manual - DEMO

3.1.3

Taxiway and auxiliary controls

Taxiway controls

Com selection provides general intensity step control to all the


Taxiway segments (i.e. on/off controls). The button set works
like the runway individual button sets but without availability/
performance blinking features.
Inc / dec com control

Control:

Selection toggles the control on/off.


Confirmation may be needed depending on the confirmation setting
Auxiliary control

Indication:

Off : Control off


Yellow : Control on and status ok (**) or com off
Yellow/slow blink: Control on and at least 50% ok
Yellow/fast blink: Control on and less than 50% ok

IDMAN PHILIPS

9 / 16

IDM 7600-S- Control Manual - DEMO

3.2

Auxiliary pop up panels

These pages appear to assist control tasks when selected from the footer of the main page.
Runway direct keyboard replaces the runway inc/dec keyboard
Other panels (only one at a time) open to the empty area on top of the screen.
Yellow indicator confirms which panels are open and selecting an active panels closes it.
3.2.1

Runway direct keyboard

This panel replaces the inc/dec keyboard and is purposed for direct brilliancy control of the
runway lights.
Open / close panel button

Control:

Selecting a button replaces any prior selection


Confirmation may be needed depending on the confirmation setting
Indication:

Direct
Controls

OFF-button:
Dark grey: control is passive (no devices configured or dir=off)
Grey : control = on (i.e. not off)
White: control = off and lights 100% available.
White / slow blink: control = off and lights less than 100% available.
White / fast blink: control = off and lights less than 50% available
Step buttons:
Dark grey: control is passive
Grey : another step is selected
Yellow : this step is selected, performance 100%
Yellow / slow blink: this step selected, performance less than 100%.
Yellow / fast blink: this step selected, performance less than 50%
For availability and performance definitions refer to runway inc/dec keyboard

IDMAN PHILIPS

10 / 16

IDM 7600-S- Control Manual - DEMO

3.2.2

Monitoring panel (optional)

This panel displays the main status of the CCRs, detailed status of the selected CCR and
main system information. The information can be used for analyzing system faults.
Open / close panel button

CCRs display
CCRs selection

Displays main status of all 16 CCRs:


Online: CCR communicates with the system
On: CCR is on
Local: CCRs is in local control mode i.e. not available for controls
Fault: CCR sum fault indication (offline excluded)
Browse CCRs with the selection buttons.
Black bar indicates the selected CCR on CCRs display
Displays detailed status of the selected CCR:
Control status

Request: CCR is requested to be on (any control step)


Step fault: CCR is not on the requested control step
Input fault indications

U1: input voltage fault (alarm/warning)


F1: input frequency fault (alarm/warning)
Temp: Temperature fault (alarm/warning)
Output fault indications

Selected CCR

Open circuit: CCR has tripped, output current below set levels
Over current: CCR has tripped, output current exceeded set levels
Current fault: CCR on, output current is not correct
VA-drop fault: CCR on, power of the circuit has decreased
Lamp fault: CCR on, lamp faults in the circuit
Earth fault: CCR on, isolation resistance has decreased

Numerical values

System

I2: output current value (RMS, A)


U2: output voltage value (RMS, V)
P2: output actual power value (W)
LF: no of lamp faults
EF: isolation resistance value (ohms)
DC UPS status: green=ok, red=fault, generates also buzzer sound
which can be silenced with alarm reset button.
PLC run counter: PLCs alive counter display confirms that live
connection to the PLC exists when the value changes.

IDMAN PHILIPS

11 / 16

IDM 7600-S- Control Manual - DEMO

3.2.3

Adjustment panel

The page contains background colour and brightness adjustments and backlight off control
and cleaning mode controls. Password is not required to open the panel.
Application version and date is also displayed here.
Open / close panel button on the main page

SELECTIONS

Adjusts the background colour from light grey to black in eight grades
Back colour

Brightness

Backlight off

Cleaning mode

Adjusts the brightness of the screen in 16 levels and displays the setting with
bar graph
Selects backlight off-mode which is useful if the panel is not used for longer
periods. The off-mode saves energy and increases the lifetime of the unit.
When entering the mode confirmation is asked and to return to normal mode
touch anywhere on the screen
Cleaning mode opens a special cleaning window where the screen can be
cleaned safely without affecting the control status of the system.
When entering the mode confirmation is asked. The page includes cleaning
and closing instructions. To close the panel select the alternate exit buttons
sequentially 3 times in 1s.
e.g. Exit1 > Exit2 > Exit 1

or

Exit 2 > Exit 1 > Exit 2

IDMAN PHILIPS

12 / 16

IDM 7600-S- Control Manual - DEMO

3.2.4

Settings panels

3.2.4.1.

Settings entry password protection

Password is required to enter the settings panels


Step

Description

Dialog

Open / close panel button on the main page.


Select to start the password dialog.
Password panel opens. Select either:
Text field to enter the password
Cancel to close the password dialog

Password input keyboard opens.


Write the password with the keyboard
select Enter to accept the password
Select Esc to close the keyboard

Confirm entry to settings panels


ok to go to system settings panel
Cancel to close the password dialog

3.2.4.2.

Main settings panel

The page contains system, control settings, offline and system log.
Open / close panel button on the main page

SETTINGS

System

Control

Opens the system setting pages where the units system settings like touch
calibration, brightness adjustment etc can be done.
The settings are divided into 2 sections: system and offline settings
Opens the control settings panel where control confirmation settings can be
done.

LOGS

Offline

System

Time & date

Opens the offline log panel which displays a list of touchscreens offline
faults
Opens the system log which displays a list of touchscreens internal faults
like communication failures with the PLC. Exits to main page.
Touchscreens internal time and date display to verify log time with other
time systems. Adjust from the system settings if needed

IDMAN PHILIPS

13 / 16

IDM 7600-S- Control Manual - DEMO

3.2.4.3.

System settings panel

Open / close panel on the settings panel


System settings

Stylus

Date / time

Restart

Ver.infot

Language

Memory

Brightness

Touch calibration. Opens calibration procedure in which 6 points need to be


touched on the screen
Time and date setting. Affects on the alarm log time information
Opens numeric keypad to enter the data.
Restarts the screens operating system (Vijeo Designer runtime).
Confirmation required.
Vijeo Designer operating system version information.
Important information in case of application / OS mismatch.
System and application language selection.
Application language can be directly selected from the application pages but
here any of the 5 available languages can be selected.
Memory usage information:
DRAM: random access memory, data memory
CF CARD: Compact flash card with application back up
Main Flash: Application memory, non volatile
Brightness setting.
lower brightness level increases the backlights operation life
Not used

Option

Offline settings

Adjusting offline settings will stop the OS.


IP-address, Subnet mask and default gateway setting
Opens numeric keypad to enter the data.
Network
Use of beep to confirm touch (does not affect on the alarm beep)
None: no beep / When touch object: beep when touch object.
Buzzer
Backlight settings:
Wait X min / screensaver: if set turns off the backlight after preset idle time.
Backlight
Enable touch if backlight is burned out: enables control even if the backlight
is not operational. (default = not selected)
Runs self test to selected HW:
Char. pattern
Disp. pattern
Self test
Touch panel
COM 1, COM 2
Video memory
Can set DC-supply output to COM1 port. Not used.(Setting = none)
Option

IDMAN PHILIPS

14 / 16

IDM 7600-S- Control Manual - DEMO

3.2.4.4.

Control system settings panel

Control button confirmation can be set for different control classes.


Confirmation means that a special confirmation window where the control can be
confirmed or cancelled opens when a control is selected.
Settings no confirmation / confirm off and confirm all can be selected and they will remain
even if the touchscreen unit is de-energized.
Open / close panel on the settings panel

SELECTIONS
Direction

3.2.4.5.

No confirmation: Controls do not need to be confirmed.


Confirm off: Only off-controls need to be confirmed.
(Landing/take-off: only take-off controls need to be confirmed)
Confirm all: All controls needs to be confirmed.
Offline log panel (touchscreen stations only)

The panel has a log for 10 last offline faults. The offline fault happens when the PLCs
heartbeat is not heard by the touchscreen panel. (PLC has stopped or total / partial
communication failure between the touchscreen and the PLC).
The log can be browsed, each line can be acknowledged and it also shows total offline
faults quantity and duration.
Open / close panel button on the settings panel

SELECTIONS AND DISPLAYS

Acknowledge selected row or all rows


Move highlighted row up/down
Browse table up/down
Row: background colour shows status: red = unacknowledged, yellow highlighted (i.e.
selected) and green ok status but unacknowledged.
Displays total offline faults quantity and duration in h and s

IDMAN PHILIPS

15 / 16

IDM 7600-S- Control Manual - DEMO

APPENDIXES

4.1

Appendix 1: Detailed fault definitions

CCR fault

Type

Blink button

Blink mimic

Control step
Online
Local
Power

P
P/A
P/A
P/A

Yes
Yes
Yes
Yes

U1 alarm

P/A

Yes

U1 warning
F1 alarm

W
P/A

No
Yes

F1 warning
Temp alarm

W
P/A

No
Yes

Temp warning
Open circuit

W
P

No
Yes

Over current

Yes

Current fault
VA alarm
VA warning
Lamp fault alarm
Lamp fault
warning
Earth fault alarm
Earth fault
warning
EF maint switch
on

P
P
W
P
W

Yes / control=on
Yes / control=on
No
Yes / control=on
No

Yes
No
No
Yes /
control=on
Yes /
control=on
No
Yes /
control=on
No
Yes /
control=on
No
Yes /
control=on
Yes /
control=on
No
No
No
No
No

W
W

No
No

No
No

No

No

Remarks

If causes step fault then mimic=yes


If causes step fault then mimic=yes
By causing step failure
By causing step failure

By causing step failure

By causing step failure

By causing step failure


By causing step failure
Only possible when CCR=on
Only possible when CCR=on
Only possible when CCR=on

Type abbreviations:
A= Availability fault: control is not requested but the CCR is not available for controls
P= Performance fault: Control is requested, CCR performance is degraded from the request
W=Warning, the fault does not degrade performance or availability significantly
This list is made according IDM 8000 CCRs indications, other CCRs may have less or different fault
indications available.
Alarm indicator and buzzer are activated only for A/P type faults (i.e. which cause the buttons to blink)

IDMAN PHILIPS

16 / 16

Вам также может понравиться