Вы находитесь на странице: 1из 13

Igreja Adventista do Stimo dia

Timon-MA
Date:

28-02-2015

Designer:

Joo Paulo S. Pinheiro

The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixed
relationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminaire
positioning, reflection properties and electrical supply.

Joo Paulo S. Pinheiro

Telephone: 8699788671
E-Mail: jpsp07@hotmail.com

CalcuLuX Area 6.4.1

Igreja Adventista do Stimo dia


Timon-MA

Joo Paulo S. Pinheiro


Date: 28-02-2015

Table of Contents

1.

Project Description

1.1
1.2

3-D Project Overview


Top Project Overview

3
4

2.

Summary

2.1
2.2
2.3
2.4

General Information
Obstacle Information
Project Luminaires
Calculation Results

5
5
5
5

3.

Calculation Results

3.1
3.2
3.3
3.4

Igreja Adventista: Textual Table


Igreja Adventista: Iso Contour
Igreja Adventista: Filled Iso Contour
Igreja Adventista: Mountain Plot

6
7
8
9

4.

Luminaire Details

10

4.1

Project Luminaires

10

5.

Installation Data

12

5.1
5.2

Legends
Luminaire Positioning and Orientation

12
12

6.

Financial Information

13

6.1
6.2
6.3

Installation Data
Luminaire Information
Total cost

13
13
13

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Page:

2/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

1. Project Description
1.1 3-D Project Overview

A
B

A
B

B
B

A
B
C

FBS245 +GBS245 T5-C60


TPX200/236 L-WH
MBN110 MB24

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Page:

3/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

10

1.2 Top Project Overview

A
C

0
-6

-5

-4

-3

-2

-1

Y(m)

-10

-9

-8

-7

-8

-7

-6

-5

-4

-3

-2

-1

X(m)

A
B
C

FBS245 +GBS245 T5-C60


TPX200/236 L-WH
MBN110 MB24
Scale
1:100

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Page:

4/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

2. Summary
2.1 General Information
The overall maintenance factor used for this project is 1.00.

2.2 Obstacle Information


Obstacle

Transparency (%)

Block

X (m)
-3.50

Position
Y (m)
-6.00

Z (m)
0.00

2.3 Project Luminaires


Code
A
B
C

Qty
5
14
4

Luminaire Type
FBS245 +GBS245 T5-C60
TPX200/236 L-WH
MBN110 MB24

Lamp Type
2 * PL-C/2P26W
2 * TL-D36W
1 * CDM-TC35W

Power (W)
66.4
70.0
47.0

Flux (lm)
2 * 1800
2 * 3200
1 * 3300

The total installed power: 1.50 (kWatt)

2.4 Calculation Results

(Il)luminance Calculations:
Calculation
Type
Igreja Adventista
Surface Illuminance

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Unit
lux

Ave Min/Ave Min/Max


391
0.00
0.00

Page:

5/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

3. Calculation Results
3.1 Igreja Adventista: Textual Table
Grid
Calculation

: Igreja Adventista at Z = 0.00 m


: Surface Illuminance (lux)

X (m)
Y (m)
8.00

-3.00

-2.00

-1.00

0.00

1.00

2.00

3.00

187

282

372

392

382

305

197

7.00

255

608

1184

1272>

1207

734

282

6.00

335

549

796

839

822

611

356

5.00

293

385

442

444

447

401

308

4.00

312

410

459

456

466

425

324

3.00

367

502

539

521

547

514

376

2.00

350

482

506

492

510

486

355

1.00

300

408

433

426

435

410

302

0.00

346

477

504

487

505

480

349

-1.00

347

477

505

488

507

482

351

-2.00

296

403

430

425

435

411

304

-3.00

317

441

467

454

478

457

334

-4.00

281

392

417

411

440

425

314

-5.00

179

243

271

288

328

313

234

-6.00

0<

0<

0<

264

291

283

212

-7.00

152

176

165

219

237

231

173

-8.00

112

123

115

143

146

139

108

Average
391

Min/Ave
0.00

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Min/Max
0.00

Project maintenance factor


1.00
Page:

6/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

3.2 Igreja Adventista: Iso Contour


: Igreja Adventista at Z = 0.00 m
: Surface Illuminance (lux)

10

Grid
Calculation

250

500

750

A
C

1250C

10
00
C

500
B

500

500
B

-6

-5

-4

-3

-2

-1

Y(m)

-7

250

-10

-9

-8

-8

-7

-6

-5

-4

-3

-2

-1

X(m)

A
B
C
Average
391

FBS245 +GBS245 T5-C60


TPX200/236 L-WH
MBN110 MB24
Min/Ave
0.00

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Min/Max
0.00

Project maintenance factor


1.00

Scale
1:100
Page:

7/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

3.3 Igreja Adventista: Filled Iso Contour


: Igreja Adventista at Z = 0.00 m
: Surface Illuminance (lux)

10

Grid
Calculation

A
C

1250

Y(m)

1000

-3

-2

-1

750

500

-6

-5

-4

250

-7

-10

-9

-8

-6

-5

-4

-3

-2

-1

X(m)

A
B
C
Average
391

FBS245 +GBS245 T5-C60


TPX200/236 L-WH
MBN110 MB24
Min/Ave
0.00

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Min/Max
0.00

Project maintenance factor


1.00

Scale
1:100
Page:

8/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

3.4 Igreja Adventista: Mountain Plot


Grid
Calculation

: Igreja Adventista at Z = 0.00 m


: Surface Illuminance (lux)

10
8
6
4
2
0

-4
-2

-2

X(m

-4

Y(m

-6

2
-8

4
-10

Average
391

Min/Ave
0.00

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Min/Max
0.00

Project maintenance factor


1.00
Page:

9/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

4. Luminaire Details
4.1 Project Luminaires
Luminous Intensity Diagram (candela/1000 lumen)
120o
150o 180 o 150o
120o

FBS245 +GBS245 T5-C60 2xPL-C/2P26W/830

Light output ratios


DLOR
ULOR
TLOR
Ballast
Lamp flux
Luminaire wattage
Measurement code

:
:
:
:
:
:
:

90o

90o

60o

60o

0.53
0.00
0.53
Standard
1800 lm
66.4 W
DL36022100

250

30o

:
:
:
:
:
:
:

30o
C = 0o
C = 90o
C = 30o

Imax

90o

90o

60o

60o

0.57
0.00
0.57
Electronic
3200 lm
70.0 W
LVL9502040

200

30o

Philips Lighting B.V. - CalcuLuX Area 6.4.1

0o

Luminous Intensity Diagram (candela/1000 lumen)


120o
150o 180 o 150o
120o

TPX200/236 L-WH 2xTL-D36W/830

Light output ratios


DLOR
ULOR
TLOR
Ballast
Lamp flux
Luminaire wattage
Measurement code

C = 180o
C = 270o
C = 210o

C = 180o
C = 270o

0o
Imax

30o
C = 0o
C = 90o

Page:

10/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

Luminous Intensity Diagram (candela/1000 lumen)


120o
150o 180 o 150o
120o

MBN110 MB24 1xCDM-TC35W/830

Light output ratios


DLOR
ULOR
TLOR
Ballast
Lamp flux
Luminaire wattage
Measurement code

:
:
:
:
:
:
:

90o

90o

60o

60o

0.69
0.00
0.69
Standard
3300 lm
47.0 W
LVL9922200

2000

30o

Philips Lighting B.V. - CalcuLuX Area 6.4.1

C = 180o
C = 270o

0o
Imax

30o
C = 0o
C = 90o

Page:

11/13

Igreja Adventista do Stimo dia


Timon-MA

Joo Paulo S. Pinheiro


Date: 28-02-2015

5. Installation Data
5.1 Legends

Project Luminaires:
Code
Qty Luminaire Type
A
5 FBS245 +GBS245 T5-C60
B
14 TPX200/236 L-WH
C
4 MBN110 MB24

Lamp Type
2 * PL-C/2P26W
2 * TL-D36W
1 * CDM-TC35W

Flux (lm)
2 * 1800
2 * 3200
1 * 3300

5.2 Luminaire Positioning and Orientation


Qty and
Code

Position

Aiming Angles

X (m)

Y (m)

Z (m)

Rot.

Tilt90

Tilt0

1*A
1*B
1*A
2*B
2*B

-2.62
-2.50
-2.33
-1.75
-1.75

7.25
-7.00
4.75
-3.50
-0.50

3.35
3.35
3.35
3.35
3.35

180.0
0.0
0.0
180.0
180.0

0.0
0.0
0.0
0.0
0.0

0.0
0.0
0.0
0.0
0.0

2*B
1*C
1*C
1*A
1*C

-1.75
-1.33
-0.38
0.17
0.54

2.50
6.80
6.80
4.75
6.80

3.35
3.35
3.35
3.35
3.35

180.0
0.0
0.0
0.0
0.0

0.0
0.0
0.0
0.0
0.0

0.0
0.0
0.0
0.0
0.0

1*C
1*B
2*B
2*B
2*B

1.49
1.75
1.75
1.75
1.75

6.80
-6.50
-3.50
-0.50
2.50

3.35
3.35
3.35
3.35
3.35

0.0
0.0
0.0
0.0
0.0

0.0
0.0
0.0
0.0
0.0

0.0
0.0
0.0
0.0
0.0

1*A
1*A

2.50
2.62

4.75
7.25

3.35
3.35

0.0
0.0

0.0
0.0

0.0
0.0

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Page:

12/13

Igreja Adventista do Stimo dia

Joo Paulo S. Pinheiro


Date: 28-02-2015

Timon-MA

6. Financial Information
6.1 Installation Data
Burning hours/year
Amortization period
Interest rate
kWh price

0
1.0
0.0
0.00

hr
yr
%

6.2 Luminaire Information


Prices ()
Project Luminaires
FBS245 +GBS245 T5-C60
TPX200/236 L-WH
MBN110 MB24

Qty
5
14
4

Lamp

Luminaire

Installation

Maintenance

0.00
0.00
0.00

0.00
0.00
0.00

0.00
0.00
0.00

0.00
0.00
0.00

Relamping
period (yr)
1.00
1.00
1.00

6.3 Total cost


Costs per year
Energy
Investment
Lamps
Maintenance
Total

0.00
0.00
0.00
0.00
------------0.00

Total investment

0.00

Philips Lighting B.V. - CalcuLuX Area 6.4.1

Page:

13/13

Вам также может понравиться