Академический Документы
Профессиональный Документы
Культура Документы
General
Specifications
EJA118E/Z
Diaphragm Sealed
Differential Pressure Transmitter
(Inner Diaphragm type)
GS 01C31H01-11EN
STANDARD SPECIFICATIONS
Span
Range
Span
Range
kPa
inH2O(/D1)
Measurement span
mbar(/D3)
2.5 to 100
10 to 400
25 to 1000
100 to 100 400 to 400 1000 to 1000
25 to 500
100 to 2000
250 to 5000
500 to 500 2000 to 2000 5000 to 5000
mmH2O(/D4)
250 to 10000
10000 to 10000
0.25 to 5 kgf/cm2
5 to 5 kgf/cm2
Reference
accuracy
X span
0.2% of Span
X > span
PERFORMANCE SPECIFICATIONS
Output
50% or Greater
50% to Dropout point
Reference X span
accuracy
X > span
0.2% of Span
(0.15+0.01 URL/span)% of Span
Reference accuracy50
Square root output (%)
Measurement span
Accuracy
Same as reference accuracy
Total shift
M and H
(0.2+0.7 X
A )%
1.4%
AX
(1.4 X
A )%
A<X
T01.ai
GS 01C31H01-11EN
Copyright June 2012
2nd Edition Oct. 2012
<<Contents>> <<Index>>
Static Pressure Effects per 0.69 MPa (100 psi)
Change
Span Effects
M and H capsules
0.02% of span
Effect on Zero
M and H capsules
0.014% of URL
Power Supply Effects (Output signal code D and J)
0.005% per Volt (from 21.6 to 32 V DC, 350 )
Response Time (Differential pressure)
M and H capsule: 200 ms (approximate value at
normal temperature)
When software damping is set to zero and including
dead time of 45 ms (nominal)
Static Pressure Signal Range and Accuracy
(For monitoring via communication or on
indicator. Includes terminal-based linearity,
hysteresis, and repeatability)
Range
Upper Range Value and Lower Range Value of the
statice pressure can be set in the range between 0
and Maximum Working Pressure (MWP*). The upper
range value must be greater than the lower range
value. Minimum setting span is 0.5 MPa (73 psi).
*: Maximum Working Pressure (MWP) is within flange
rating pressure.
Accuracy
Absolute Pressure
1 MPa or higher : 0.5% of span
Less than 1 MPa: 0.5%(1 MPa/span) of span
Gauge Pressure Reference
Gauge pressure reference is 1013 hPa (1 atm)
FUNCTIONAL SPECIFICATIONS
Output
Two wire 4 to 20 mA DC output with digital
communications, linear or square root programmable.
BRAIN or HART FSK protocol are superimposed on
the 4 to 20 mA signal.
Output range: 3.6 mA to 21.6 mA
Output limits conform to NAMUR NE43 can be preset by option code C2 or C3.
Damping Time Constant (1st order)
Amplifier damping time constant is adjustable from
0.00 to 100.00 s by software and added to response
time.
Note: For BRAIN protocol type, when amplifier software
damping is set to less than 0.5 s, communication
may occasionally be unavailble during the
operation, especially while output changes
dynamically. The default setting of damping
ensures stable communication.
Update Period
Differential pressure: 45 ms
Static pressure: 360 ms
Zero Adjustment Limits
Zero can be fully elevated or suppressed, within the
lower and upper range limits of the capsule.
GS 01C31H01-11EN
<<Contents>> <<Index>>
Table 1. Process temperature, Ambient temperature, and Working pressure
1
2
Code Process temperature* Ambient temperature*
Working pressure
Specific gravity*3
1.07
10 to 250C
(14 to 482F)
10 to 60C
(14 to 140F)
30 to 180C
(22 to 356F)
15 to 60C
(5 to 140F)
Fluorinated oil
(oil-prohibited use)
20 to 120C
(4 to 248F)
10 to 60C
(14 to 140F)
51 kPa abs
(7.4 psi abs)
to flange rating pressure
1.90 to 1.92
Ethylene glycol
(low temperature use)
50 to 100C
(58 to 212F)
40 to 60C
(40 to 140F)
1.09
Silicone oil
(high temp. and high
vacuum use)
10 to 250C
(14 to 482F)
10 to 50C
(14 to 122F)
Silicone oil
(high vacuum use)
10 to 100C
(14 to 212F)
10 to 50C
(14 to 122F)
0.94
1.07
1.07
*1: See figure 1-1, 1-2, 1-3, and 1-4 Working Pressure and Process Temperature.
*2: This ambient temperature is the transmitter ambient temperature.
*3: Approximate values at a temperature of 25C (77F)
Note: The differential pressure transmitter should be installed at least 600 mm below the high pressure (HP) process connection.
However, this value (600 mm) may be affected by ambient temperature, operating pressure, fill fluid or material of the
wetted diaphragm.
Contact YOKOGAWA when the transmitter can not be installed at least 600 mm below the HP process connection.
Transmitter ambient
temperature range
(for fill fluid code
A, B)
Process temperature
for fill fluid code B
Process temperature
for fill fluid code A
Flange max.
working
pressure
Atmospheric
pressure
100 (14.5)
Working
pressure
kPa abs
(psi abs)
Transmitter ambient
temperature range
(for fill fluid code D)
51 (7.4)
10(1.4)
2.7 (0.38)
2.7 (0.38)
1 (0.14)
1 (0.14)
0.1(0.014)
-50 0
0.1(0.014)
-50 0
F01E.ai
Atmospheric
pressure
100 (14.5)
Working
pressure
kPa abs
(psi abs)
10(1.4)
Process temperature
for fill fluid code E
Process temperature
for fill fluid code D
Flange max.
working
pressure
F02E.ai
GS 01C31H01-11EN
<<Contents>> <<Index>>
Transmitter ambient
temperature range
Process temperature
for fill fluid code 1
Flange max.
working
pressure
Atmospheric
pressure
100(14.5)
Working
pressure
kPa abs
(psi abs)
600
R=
10(1.4)
External
load
resistance
2.7(0.38)
E-10.5
0.0244
Digital
Communication
range
BRAIN and HART
250
1(0.14)
R ()
0.1(0.014)
25.2
10.5 16.6
Power supply voltage E (V DC)
0.013(0.0019)
0.01(0.0014)
-50 0
F03E.ai
F12E.ai
Transmitter ambient
temperature range
Process temperature
for fill fluid code 4
Flange max.
working
pressure
Atmospheric
pressure
100(14.5)
Working
pressure
kPa abs
(psi abs)
10(1.4)
2.7(0.38)
1(0.14)
0.1(0.014)
0.013(0.0019)
0.01(0.0014)
-50 0
42
F13E.ai
Supply Voltage
10.5 to 42 V DC for general use and flameproof type.
10.5 to 32 V DC for lightning protector (option code
/A).
10.5 to 30 V DC for intrinsically safe, type n, or nonincendive.
Minimum voltage limited at 16.6 V DC for digital
communications, BRAIN and HART
Load (Output signal code D and J)
0 to 1290 for operation
250 to 600 for digital communication
Communication Requirements
(Approval codes may affect electrical
requirements.)
BRAIN
Communication Distance
Up to 2 km (1.25 miles) when using CEV
polyethylene-insulated PVC-sheathed cables.
Communication distance varies depending on type of
cable used.
Load Capacitance
0.22 F or less
Load Inductance
3.3 mH or less
Input Impedance of communicating device
10 k or more at 2.4 kHz.
,
EMC Conformity Standards
EN61326-1 Class A, Table2 (For use in industrial
locations)
EN61326-2-3
European Pressure Equipment Directive 97/23/EC
Sound Engineering Practice
GS 01C31H01-11EN
<<Contents>> <<Index>>
PHYSICAL SPECIFICATIONS
Process connections
See the following table.
Table 2. Flange size and rating
Process
connection style
Size
Flange
Adapter
connection type
1/2-inch
3/4-inch
1-inch
Flange
connection type
1/2-inch
3/4-inch
1-inch
JIS/JPI
SA, WA,
SD WD
ANSI
SA, WA,
SD WD
Electrical Connections
See MODEL AND SUFFIX CODES.
Transmitter Mounting
2-inch pipe mounting
Wetted Parts Material
Diaphragm seal
Diaphragm and other wetted parts;
Refer to MODEL AND SUFFIX CODES.
Vent / Drain plugs
316 SST
Flange Material
Refer to MODEL AND SUFFIX CODES.
(It means the material of adapter or pipe with
flange.)
Gasket for transmitter side
316L SST with PTFE Teflon coating
Non-wetted Parts Material
Transmitter body section:
Cover flange
ASTM CF-8M
Cover flange bolting
B7 carbon steel, 316L SST or 660 SST
Housing
Low copper cast aluminum alloy with polyurethane,
deep sea moss green paint (Munsell 0.6GY3.1/2.0
or its equivalent) or ASTM CF-8M stainless steel
Degrees of Protection
IP66/IP67, NEMA4X
Cover O-rings
Buna-N, fluoro-rubber (optional)
Name plate and tag
316 SST
GS 01C31H01-11EN
<<Contents>> <<Index>>
See Page 7
Inner diaphragm,
Adapter connection type See Page 8
Inner diaphragm,
Flange connection type See Page 9
F04E.ai
GS 01C31H01-11EN
<<Contents>> <<Index>>
EJA118E
F05E.ai
Model
EJA118E
Suffix codes
Description
Diaphragm sealed differential pressure transmitter
Output signal
-D
-J
-F
M
Measurement span
(capsule)
Always S
Always C
B7 carbon steel
316L SST
660 SST
-9
Electrical connection
G1/2 female, two electrical connections and a 316 SST blind plug
1/2 NPT female, two electrical connections and a 316 SST blind plug
M20 female, two electrical connections and a 316 SST blind plug
Integral Indicator
Digital indicator
None
Mounting braket
*4
304 SST 2-inch pipe mounting, flat type (for horizontal piping)
316 SST 2-inch pipe mounting, flat type (for horizontal piping)
None
The marks indicate the most typical selection for each specification.
*1: HART 5 or HART 7 is selectable. Specify upon ordering.
*2: Not applicable for electrical connection code 0, 5, 7, 9 and A. Content rate of copper in the material is 0.03% or less and
content rate of iron is 0.15% or less.
*3: Not applicable for electrical connection code 0, 5, 7 and 9.
*4: Material of a blind plug is aluminum alloy or 304 SST.
*5: Not applicable for output signal code F.
GS 01C31H01-11EN
<<Contents>> <<Index>>
6
7
1
F06E.ai
Model
Suffix codes
Description
EJA118E
-A
Flange rating
J1
JIS 10K
J2
JIS 20K
J4
JIS 40K
A1
A2
A4
Extension
[Diaphragm]
[Others]
SA
316L SST
WA
Hastelloy C-276 *5 #
None
None
Fill fluid*5
[Process
temperature]
[Ambient
temperature]
-A
10 to 250C
10 to 60C
-B
30 to 180C
15 to 60C
-D
20 to 120C
10 to 60C
-E
50 to 100C
40 to 60C
-1
10 to 50C
-4
10 to 50C
Capillary connection
Capillary treatment*6
Standard
Capillary length*7
10 to 100C
1 m*6
6 6 m
2m
7 7 m
3m
8 8 m
4m
9 9 m
5m
A 10 m
The marks indicate the most typical selection for each specification. Example: EJA118E-DMSCG-912EN-AA16E2SA00-BB15//Z
*1: See table 3 Gasket contact surface on page 5.
*2: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing
and dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
*3: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of
inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage
to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm
and the fill fluid can contaminate the users process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium
hypochlorite, and high-temperature steam (150C [302F] or above). Contact Yokogawa for detailed information of the
wetted parts material.
*4: Forged version of the material may be used.
*5: Hastelloy C-276 or N10276.
*6: In case where capillary length code 1 (1 m) is selected, capillary treatment must be selected code 2 (None).
*7: In case of wetted parts material code WA (Hastelloy C), specify capillary length from 1 to 5m.
*8: In case where flange rating code A4 (ANSI class 600) or P4 (JPI class 600) is selected, It must be selected optional code
/HP (High pressure-proof structure).
The # marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please
refer to the latest standards for details. Selected materials also conform to NACE MR0103.
GS 01C31H01-11EN
<<Contents>> <<Index>>
6
7
1
F07E.ai
Model
EJA118E
Suffix codes
-D
Flange rating
J1
JIS 10K
J2
JIS 20K
J4
JIS 40K
A1
A2
A4
P1
P2
P4
Process connection size
(Process flange size)
Flange material*3
Extension
Capillary treatment*6
Capillary length*7
None
None
[Others]
316 SST *4
316 SST *4 #
[Process
temperature]
[Ambient
temperature]
-A
10 to 250C
10 to 60C
-B
30 to 180C
15 to 60C
20 to 120C
10 to 60C
Fill fluid
Capillary connection
SD
WD
Flushing connection ring
Description
-D
-E
40 to 60C
-1
10 to 50C
-4
10 to 50C
10 to 100C
Standard
1 m*6
6 6 m
2m
7 7 m
3m
8 8 m
4m
9 9 m
5m
A 10 m
The marks indicate the most typical selection for each specification. Example: EJA118E-DMSCG-912EN-DA16D2SD00-BB15//Z
*1: See table 3 Gasket contact surface on page 5.
*2: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing
and dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
*3: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of
inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage
to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm
and the fill fluid can contaminate the users process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium
hypochlorite, and high-temperature steam (150C [302F] or above). Contact Yokogawa for detailed information of the
wetted parts material.
*4: Forged version of the material may be used.
*5: Hastelloy C-276 or N10276.
*6: In case where capillary length code 1 (1 m) is selected, capillary treatment must be selected code 2 (None).
*7: In case of wetted parts material code WD (Hastelloy C), specify capillary length from 1 to 5m.
*8: In case where flange rating code A4 (ANSI class 600) or P4 (JPI class 600) is selected, It must be selected optional code
/HP (High pressure-proof structure).
The # marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please
refer to the latest standards for details. Selected materials also conform to NACE MR0103.
GS 01C31H01-11EN
10
<<Contents>> <<Index>>
ATEX
Description
FM Explosionproof Approval *1
Applicable Standard: FM3600, FM3615, FM3810, ANSI/NEMA 250
Explosionproof for Class I, Division 1, Groups B, C and D, Dust-ignitionproof for Class II/III, Division 1,
Groups E, F and G, in Hazardous locations, indoors and outdoors (NEMA 4X)
FACTORY SEALED, CONDUIT SEAL NOT REQUIRED.
Temperature class: T6, Amb. Temp.: 40 to 60C (40 to 140F) *2
FM Intrinsically safe Approval *1
Applicable Standard: FM3600, FM3610, FM3611, FM3810
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,
Groups E, F & G and Class III, Division 1, Class I, Zone 0, in Hazardous Locations, AEx ia IIC
Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,
Groups F & G, Class I, Zone 2, Group IIC, in Hazardous Locations
Enclosure: NEMA 4X, Temp. Class: T4, Amb. Temp.: 60 to 60C (75 to 140F) *2
Intrinsically Safe Apparatus Parameters
[Groups A, B, C, D, E, F and G] Vmax=30 V, Imax=200 mA, Pmax=1 W, Ci=6 nF, Li=0 H
[Groups C, D, E, F and G] Vmax=30 V, Imax=225 mA, Pmax=1 W, Ci=6 nF, Li=0 H
Combined FF1 and FS1 *1
ATEX Flameproof Approval *1
Applicable Standard: EN 60079-0, EN 60079-1, EN 60079-31
Certificate: KEMA 07ATEX0109 X
II 2G, 2D Ex d IIC T6...T4 Gb, Ex tb IIIC T85C Db IP6X
Degree of protection: IP66/IP67
Amb. Temp. (Tamb) for gas-proof :
T4; 50 to 75C (58 to 167F), T5; 50 to 80C (58 to 176F), T6; 50 to 75C (58 to 167F)
Max. process Temp. for gas-proof (Tp): T4; 120C (248F), T5; 100C (212F), T6; 85C (185F)
Max. surface Temp. for dust-proof: T85C (Tamb: 30 to 75C, Tp: 85C) *2
ATEX Intrinsically safe Approval *1
Applicable Standard: EN 60079-0, EN 60079-11, EN 60079-26, EN 61241-11
Certificate: DEKRA 11ATEX0228 X
II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85C T100C T120C Db
Degree of protection: IP66/IP67
Amb. Temp. (Tamb) for EPL Ga: 50 to 60C (58 to 140F)
Maximum Process Temp. (Tp) for EPL Ga:120C
Electrical data: Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 H
Amb. Temp. for EPL Db: 30 to 60C *2
Max. surface Temp. for EPL Db: T85C (Tp: 80C), T100C (Tp: 100C), T120C (Tp: 120C)
Combined KF22, KS21 and Type n *1
Type n
Applicable Standard: EN 60079-0, EN 60079-15
II 3G Ex nL IIC T4 Gc, Amb. Temp.: 30 to 60C (22 to 140F) *2
Ui=30 V DC, Ci=10 nF, Li=0 H
GS 01C31H01-11EN
Code
FF1
FS1
FU1
KF22
KS21
KU22
11
<<Contents>> <<Index>>
Item
Canadian
Standards
Association
(CSA)
IECEx
*1:
*2:
Description
CSA Explosionproof Approval *1
Certificate: 2014354
Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.0.5, C22.2 No.25, C22.2 No.30,
C22.2 No.94, C22.2 No.60079-0, C22.2 No.60079-1, C22.2 No.61010-1-04
Explosion-proof for Class I, Groups B, C and D.
Dustignition-proof for Class II/III, Groups E, F and G.
When installed in Division 2, SEAL NOT REQUIRED Enclosure: NEMA 4X, Temp. Code: T6...T4
Ex d IIC T6...T4 Enclosure: IP66/IP67
Max.Process Temp.: T4;120C(248F), T5;100C(212F), T6; 85C(185F)
Amb.Temp.: 50 to 75C(58 to 167F) for T4, 50 to 80C(58 to 176F) for T5,
50 to 75C(58 to 167F) for T6 *2
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
CSA Intrinsically safe Approval *1
Certificate: 1606623
[For CSA C22.2]
Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.25, C22.2 No.94, C22.2 No.157,
C22.2 No.213, C22.2 No.61010-1
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G,
Class III, Division 1, Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2,
Groups F & G, Class III, Division 1
Enclosure: NEMA 4X, Temp. Code: T4 Amb. Temp.: 50 to 60C(58 to 140F) *2
Electrical Parameters: [Intrinsically Safe] Vmax=30V, Imax=200mA, Pmax=0.9W, Ci=10nF, Li=0 H
[Nonincendive] Vmax=30V, Ci=10nF, Li=0 H
[For CSA E60079]
Applicable Standard: CAN/CSA E60079-0, CAN/CSA E60079-11, CAN/CSA E60079-15,
IEC 60529:2001-02
Ex ia IIC T4, Ex nL IIC T4 Enclosure: IP66/IP67
Amb. Temp.: 50 to 60C(58 to 140F) *2, Max. Process Temp.: 120C(248F)
Electrical Parameters: [Ex ia] Ui=30V, Ii=200mA, Pi=0.9W, Ci=10nF, Li=0 H
[Ex nL] Ui=30V, Ci=10nF, Li=0 H
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
Combined CF1 and CS1 *1
IECEx Flameproof Approval *1
Applicable Standard: IEC 60079-0:2004, IEC60079-1:2003
Certificate: IECEx CSA 07.0008
Flameproof for Zone 1, Ex d IIC T6...T4 Enclosure: IP66/IP67
Max.Process Temp.: T4;120C(248F), T5;100C(212F), T6; 85C(185F)
Amb.Temp.: 50 to 75C(58 to 167F) for T4, 50 to 80C(58 to 176F) for T5,
50 to 75C(58 to 167F) for T6 *2
Code
CF1
SF2
GS 01C31H01-11EN
12
<<Contents>> <<Index>>
OPTIONAL SPECIFICATIONS
Item
Color change
Coating change
Anti-corrosion coating*1*2
X2
HC
Fluoro-rubber O-ring
All O-rings of amplifier housing. Lower limit of ambient temperature: 15C (5F)
HE
Lightning protector
Oil-prohibited use
K1
Oil-prohibited use
with dehydrating treatment
K5
Painting
Description
Code
P
PR
Calibration units
*4
D1
D3
D4
Output limits
and failure operation *6
Failure alarm down-scale : Output status at CPU failure and hardware error is 5%,
3.2mA DC or less.
C1
C2
C3
Gold-plated diaphragm
Inside of isolating diaphragms (fill fluid side) are gold plated, effective for hydrogen
permeation.
A1
N4
Material certificate
Software damping
*1:
*2:
*3:
*4:
*5:
*6:
*7:
CA
CB
M2A
M8A
M2D
M8D
GS 01C31H01-11EN
13
<<Contents>> <<Index>>
Item
Pressure test/Leak test
Certificate *1
Long Vent
(Flange rating)
Description
(Test pressure)
JIS 10K
JIS 20K
JIS 40K
Code
T51
T54
T57
T52
T56
T58
High pressure-proof structure*3 High pressure-proof structure for ANSI/JPI class 600 flange.
*1:
*2:
*3:
U2
HP
The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D4.
Pure nitrogen gas is used for oil-prohibited use (option code K1 and K5.)
In case where flange rating code A4 (ANSI class 600) or P4 (JPI class 600) is selected, optional code /HP (High pressureproof structure) must be selected.
DIMENSIONS
Transmitter body section
Unit: mm (Approx.: inch)
83(3.27)
Terminal side
129(5.08)
Ground terminal
70
(2.76)
39
12
(0.47) (1.54)
Zero adjustment
175(6.89)
47
110(4.33)
Conduit connection
89(3.50)
(1.85)
315(12.40)
Electrical connection
for code 5 and 9.
Integral indicator
(optional)
95(3.74)
54
(2.13)
124(4.88)
6
(0.24)
137(5.39)
78(3.07)
External indicator
conduit connection
(optional)
Shrouding bolt
(for flame-proof type)
Mounting bracket
(flat-type, optional)
2-inch pipe
(O.D. 60.5 mm)
F08E.ai
GS 01C31H01-11EN
14
<<Contents>> <<Index>>
n-S
g
f
T
Drain
Vent plug
m*3
m+85(3.35)*4
Drain
Vent plug
Stud Bolt*1
(Nut included)
Process
High Pressure
Side
106
(4.17)
Low Pressure
Side
C*5
95(3.74)
95(3.74)
115(4.53)
88.9(3.50)
95.3(3.75)
95.3(3.75)
89(3.50)
95(3.74)
95(3.74)
70(2.76)
70(2.76)
80(3.15)
60.5(2.38)
66.5(2.62)
66.5(2.62)
60.5(2.38)
66.5(2.62)
66.5(2.62)
51(2.01)
51(2.01)
55(2.17)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
52(2.05)
52(2.05)
52(2.05)
52(2.05)
52(2.05)
62(2.44)
52(2.05)
52(2.05)
62(2.44)
1(0.04)
72(2.83)
1(0.04)
72(2.83)
1(0.04) 79.5(3.13)
1.6(0.06) 72(2.83)
1.6(0.06) 72(2.83)
6.4(0.25) 72(2.83)
1.6(0.06) 72(2.83)
1.6(0.06) 72(2.83)
6.4(0.25) 72(2.83)
4
4
4
4
4
4
4
4
4
M12 1.75
M12 1.75
M16 2.0
1/2-13UNC
1/2-13UNC
1/2-13UNC
1/2-13UNC
1/2-13UNC
1/2-13UNC
L
(Reference)
43(1.69)
43(1.69)
57(2.24)
44(1.73)
44(1.73)
59(2.32)
44(1.73)
44(1.73)
59(2.32)
C*5
100(3.94)
100(3.94)
120(4.72)
98.6(3.88)
117.3(4.62)
117.3(4.62)
99(3.90)
117(4.61)
117(4.61)
75(2.95)
75(2.95)
85(3.35)
69.9(2.75)
82.6(3.25)
82.6(3.25)
69.8(2.75)
82.6(3.25)
82.6(3.25)
56(2.20)
56(2.20)
60(2.36)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
52(2.05)
52(2.05)
52(2.05)
52(2.05)
52(2.05)
62(2.44)
52(2.05)
52(2.05)
62(2.44)
1(0.04)
1(0.04)
1(0.04)
1.6(0.06)
1.6(0.06)
6.4(0.25)
1.6(0.06)
1.6(0.06)
6.4(0.25)
72(2.83)
72(2.83)
82(3.23)
72(2.83)
80.7(3.18)
80.7(3.18)
72(2.83)
80.7(3.18)
80.7(3.18)
4
4
4
4
4
4
4
4
4
M12 1.75
M12 1.75
M16 2.0
1/2-13UNC
5/8-11UNC
5/8-11UNC
1/2-13UNC
5/8-11UNC
5/8-11UNC
4
4
4
4
4
4
4
4
4
M16 2.0
M16 2.0
M16 2.0
1/2-13UNC
5/8-11UNC
5/8-11UNC
1/2-13UNC
5/8-11UNC
5/8-11UNC
Capillary Length
A*2
L
(Reference)
43(1.69)
43(1.69)
57(2.24)
44(1.73)
51(2.01)
67(2.64)
44(1.73)
51(2.01)
67(2.64)
C*5
125(4.92)
125(4.92)
130(5.12)
108(4.25)
124(4.88)
124(4.88)
108(4.25)
124(4.88)
124(4.88)
90(3.54)
90(3.54)
95(3.74)
79.2(3.12)
88.9(3.50)
88.9(3.50)
79.2(3.12)
88.9(3.50)
88.9(3.50)
67(2.64)
67(2.64)
70(2.76)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
52(2.05)
52(2.05)
52(2.05)
52(2.05)
52(2.05)
62(2.44)
52(2.05)
52(2.05)
62(2.44)
1(0.04) 84.5(3.33)
1(0.04) 84.5(3.33)
1(0.04)
87(3.43)
1.6(0.06) 76(2.99)
1.6(0.06) 84(3.31)
6.4(0.25) 84(3.31)
1.6(0.06) 76(2.99)
1.6(0.06) 84(3.31)
6.4(0.25) 84(3.31)
L
(Reference)
57(2.24)
57(2.24)
57(2.24)
44(1.73)
51(2.01)
67(2.64)
44(1.73)
51(2.01)
67(2.64)
GS 01C31H01-11EN
F09E.ai
15
<<Contents>> <<Index>>
Process
108
(4.25)
n-h
Drain
Vent plug
77.5*2
(3.05)
106
(4.17)
162.5*3
(6.40)
High Pressure
Side
Capillary Length
Low Pressure
Side
A*1
D
95(3.74)
95(3.74)
115(4.53)
88.9(3.50)
95.3(3.75)
95.3(3.75)
89(3.50)
95(3.74)
95(3.74)
C
70(2.76)
70(2.76)
80(3.15)
60.5(2.38)
66.5(2.62)
66.5(2.62)
60.5(2.38)
66.5(2.62)
66.5(2.62)
g
51(2.01)
51(2.01)
55(2.17)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
T
39(1.54)
39(1.54)
39(1.54)
39(1.54)
39(1.54)
60(2.36)
39(1.54)
39(1.54)
60(2.36)
t
12(0.47)
14(0.55)
20(0.79)
11.2(0.44)
14.3(0.56)
14.3(0.56)
11.2(0.44)
14.3(0.56)
14.3(0.56)
f
1(0.04)
1(0.04)
1(0.04)
1.6(0.06)
1.6(0.06)
6.4(0.25)
1.6(0.06)
1.6(0.06)
6.4(0.25)
n
4
4
4
4
4
4
4
4
4
h
15(0.59)
15(0.59)
19(0.75)
15.7(0.62)
15.7(0.62)
15.7(0.62)
16(0.63)
16(0.63)
16(0.63)
g
56(2.20)
56(2.20)
60(2.36)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
T
39(1.54)
39(1.54)
39(1.54)
39(1.54)
39(1.54)
60(2.36)
39(1.54)
39(1.54)
60(2.36)
t
14(0.55)
16(0.63)
20(0.79)
12.7(0.50)
15.8(0.62)
15.8(0.62)
12.7(0.50)
15.8(0.62)
15.8(0.62)
f
1(0.04)
1(0.04)
1(0.04)
1.6(0.06)
1.6(0.06)
6.4(0.25)
1.6(0.06)
1.6(0.06)
6.4(0.25)
n
4
4
4
4
4
4
4
4
4
h
15(0.59)
15(0.59)
19(0.75)
15.7(0.62)
19.1(0.75)
19.1(0.75)
16(0.63)
19(0.75)
19(0.75)
g
67(2.64)
67(2.64)
70(2.76)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
T
39(1.54)
39(1.54)
39(1.54)
39(1.54)
39(1.54)
60(2.36)
39(1.54)
39(1.54)
60(2.36)
t
14(0.55)
16(0.63)
22(0.87)
14.3(0.56)
17.6(0.69)
17.6(0.69)
14.3(0.56)
17.6(0.69)
17.6(0.69)
f
1(0.04)
1(0.04)
1(0.04)
1.6(0.06)
1.6(0.06)
6.4(0.25)
1.6(0.06)
1.6(0.06)
6.4(0.25)
n
4
4
4
4
4
4
4
4
4
h
19(0.75)
19(0.75)
19(0.75)
15.7(0.62)
19.1(0.75)
19.1(0.75)
16(0.63)
19(0.75)
19(0.75)
D
100(3.94)
100(3.94)
120(4.72)
98.6(3.88)
117.3(4.62)
117.3(4.62)
99(3.90)
117(4.61)
117(4.61)
C
75(2.95)
75(2.95)
85(3.35)
69.9(2.75)
82.6(3.25)
82.6(3.25)
69.8(2.75)
82.6(3.25)
82.6(3.25)
D
125(4.92)
125(4.92)
130(5.12)
108(4.25)
124(4.88)
124(4.88)
108(4.25)
124(4.88)
124(4.88)
C
90(3.54)
90(3.54)
95(3.74)
79.2(3.12)
88.9(3.50)
88.9(3.50)
79.2(3.12)
88.9(3.50)
88.9(3.50)
F10E.ai
GS 01C31H01-11EN
16
<<Contents>> <<Index>>
Terminal Wiring
Terminal Configuration
Communication
terminals (BT200 etc.)
connection hook
Check meter
connection hook*1*2
SUPPLY
CHECK
SUPPLY +
SUPPLY
CHECK +
CHECK
F11E.ai
GS 01C31H01-11EN
17
<<Contents>> <<Index>>
As specified in order
Software
damping *1
Output mode
Calibration
range lower
range value
As specified in order
Calibration
range upper
range value
As specified in order
Calibration
range units
Display setting
JIS
316
SUS316
F316
SUSF316
316L
F316L
SUS316L
304
SUS304
F304
SUSF304
660
SUH660
B7
SNB7
CF-8M
SCS14A
SUSF316L
GS 01C31H01-11EN