Вы находитесь на странице: 1из 17

<<Contents>> <<Index>>

General
Specifications

EJA118E/Z
Diaphragm Sealed
Differential Pressure Transmitter
(Inner Diaphragm type)

GS 01C31H01-11EN

Diaphragm seals are used to prevent process medium


form entering directly into the pressure-sensing
assembly of the differential pressure transmitter, they
are connected to the transmitter using capillaries filled
with fill fluid.
Inner diaphragm type can be installed to small size
frange which is 1 inch, 3/4 inch or 1/2 inch.
And the performance is the same as 2 inch, because
it is used the daiaphragm size same as 2 inch.
EJA118E Diaphragm Sealed Differential Pressure
Transmitters can be used to measure liquid, gas,
or steam flow, as well as liquid level, density, and
pressure. EJA118E outputs a 4 to 20 mA DC signal
corresponding to the measured differential pressure.
Its highly accurate and stable sensor can also
measure the static pressure which can be shown on
the integral indicator or remotely monitored via BRAIN
or HART communications. Other key features include
quick response, remote set-up using communications,
and diagnostics. Foundation Fieldbus protocol type is
also available.

Adapter connection type

STANDARD SPECIFICATIONS

Flange connection type

Refer to GS 01C31T02-01EN for Fieldbus


communication type marked with .

SPAN AND RANGE LIMITS


Measurement
Span/Range
M
H

Span
Range
Span
Range

kPa

inH2O(/D1)

Measurement span

mbar(/D3)

2.5 to 100
10 to 400
25 to 1000
100 to 100 400 to 400 1000 to 1000
25 to 500
100 to 2000
250 to 5000
500 to 500 2000 to 2000 5000 to 5000

mmH2O(/D4)
250 to 10000
10000 to 10000
0.25 to 5 kgf/cm2
5 to 5 kgf/cm2

Reference
accuracy

X span

0.2% of Span

X > span

(0.15+0.01 URL/span)% of Span

100 kPa (400 inH2O)

URL (upper range limit)

500 kPa (2000 inH2O)

Square Root Output Accuracy


The square root accuracy is a percent of flow span.

PERFORMANCE SPECIFICATIONS

Zero-based calibrated span, linear output, wetted


parts material code S, fill fluid code B, and capillary
length of 5 m.
For Fieldbus communication type, use caribrated
range instead of span in the following specifications.
Specification Conformance
EJA-E series ensures specification conformance to at
least 3.
Reference Accuracy of Calibrated Span
(includes terminal-based linearity, hysteresis, and
repeatability)

Output
50% or Greater
50% to Dropout point

Reference X span
accuracy
X > span

0.2% of Span
(0.15+0.01 URL/span)% of Span

20 kPa (80 inH2O)

URL (upper range limit)

100 kPa (400 inH2O)

Reference accuracy50
Square root output (%)

Ambient Temperature Effects per 50C (122F)


Change
Capsule
Zero shift

Measurement span

Accuracy
Same as reference accuracy

Total shift

M and H
(0.2+0.7 X
A )%
1.4%

AX

(1.4 X
A )%

A<X
T01.ai

A is the highest value among the absolute values


of lower range value (LRV) and upper range value
(URV), and the span value in calibration range.

Yokogawa Electric Corporation


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan
Tel.: 81-422-52-5690 Fax.: 81-422-52-2018

GS 01C31H01-11EN
Copyright June 2012
2nd Edition Oct. 2012

<<Contents>> <<Index>>
Static Pressure Effects per 0.69 MPa (100 psi)
Change
Span Effects
M and H capsules
0.02% of span
Effect on Zero
M and H capsules
0.014% of URL
Power Supply Effects (Output signal code D and J)
0.005% per Volt (from 21.6 to 32 V DC, 350 )
Response Time (Differential pressure)
M and H capsule: 200 ms (approximate value at
normal temperature)
When software damping is set to zero and including
dead time of 45 ms (nominal)
Static Pressure Signal Range and Accuracy
(For monitoring via communication or on
indicator. Includes terminal-based linearity,
hysteresis, and repeatability)
Range
Upper Range Value and Lower Range Value of the
statice pressure can be set in the range between 0
and Maximum Working Pressure (MWP*). The upper
range value must be greater than the lower range
value. Minimum setting span is 0.5 MPa (73 psi).
*: Maximum Working Pressure (MWP) is within flange
rating pressure.

Accuracy
Absolute Pressure
1 MPa or higher : 0.5% of span
Less than 1 MPa: 0.5%(1 MPa/span) of span
Gauge Pressure Reference
Gauge pressure reference is 1013 hPa (1 atm)

Note : Gauge pressure variable is based on the above


fixed reference and thus subject to be affected by
the change of atomospheric pressure.

FUNCTIONAL SPECIFICATIONS
Output
Two wire 4 to 20 mA DC output with digital
communications, linear or square root programmable.
BRAIN or HART FSK protocol are superimposed on
the 4 to 20 mA signal.
Output range: 3.6 mA to 21.6 mA
Output limits conform to NAMUR NE43 can be preset by option code C2 or C3.
Damping Time Constant (1st order)
Amplifier damping time constant is adjustable from
0.00 to 100.00 s by software and added to response
time.
Note: For BRAIN protocol type, when amplifier software
damping is set to less than 0.5 s, communication
may occasionally be unavailble during the
operation, especially while output changes
dynamically. The default setting of damping
ensures stable communication.

External Zero Adjustment


External zero is continuously adjustable with 0.01%
incremental resolution of span. Re-range can be
done locally using the digital indicator with rangesetting switch.
Integral Indicator (LCD display, optional)
5-digit numerical display, 6-digit unit display and bar
graph.
The indicator is configurable to display one or up to
four of the following variables periodically.;
Measured differential pressure, differential pressure
in %, scaled differential pressure, measured static
pressure. See also Factory Setting.
Self Diagnostics
CPU failure, hardware failure, configuration error,
process alarm for differential pressure, static
pressure or capsule temperature.
User-configurable process high/low alarm for
differential pressure and static pressure is also
available.
Signal Characterizer (Output signal code D and J)
User-configurable 10-segment signal characterizer
for 4 to 20 mA output.
Capillary Fill Fluid Density Compensation
(Output signal code D and J)
Compensation of the zero shift by the ambient
temperature effect on the capillary tube.
SIL Certification
EJA-E series transmitters except Fieldbus
communication type are certified in compliance with
the following standards;
IEC 61508: 2000; Part1 to Part 7
Functional Safety of Electrical/electronic/
programmable electronic related systems; SIL 2
capability for single transmitter use, SIL 3 capability
for dual transmitter use.

NORMAL OPERATING CONDITION


(Optional features or approval codes may affect
limits.)

Ambient Temperature Limits


40 to 60C (40 to 140F)
30 to 60C (22 to 140F) with LCD display

(Note : The ambient temperature limits must be within the fill


fluid operating temperature range, see table 1.)

Process Temperature Limits


See table 1.
Ambient Humidity Limits
0 to 100% RH
Working Pressure Limits
See table 1.
For atmospheric pressure or below, see figure 1-1,
1-2, 1-3, and 1-4.

Update Period
Differential pressure: 45 ms
Static pressure: 360 ms
Zero Adjustment Limits
Zero can be fully elevated or suppressed, within the
lower and upper range limits of the capsule.

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

Oct. 01, 2012-00

<<Contents>> <<Index>>
Table 1. Process temperature, Ambient temperature, and Working pressure
1
2
Code Process temperature* Ambient temperature*

Working pressure

Specific gravity*3

2.7 kPa abs


(0.38 psi abs)
to flange rating pressure

1.07

Silicone oil (general use)

10 to 250C
(14 to 482F)

10 to 60C
(14 to 140F)

Silicone oil (general use)

30 to 180C
(22 to 356F)

15 to 60C
(5 to 140F)

Fluorinated oil
(oil-prohibited use)

20 to 120C
(4 to 248F)

10 to 60C
(14 to 140F)

51 kPa abs
(7.4 psi abs)
to flange rating pressure

1.90 to 1.92

Ethylene glycol
(low temperature use)

50 to 100C
(58 to 212F)

40 to 60C
(40 to 140F)

100 kPa abs


(atmospheric pressure)
to flange pressure rating

1.09

Silicone oil
(high temp. and high
vacuum use)

10 to 250C
(14 to 482F)

10 to 50C
(14 to 122F)

Silicone oil
(high vacuum use)

10 to 100C
(14 to 212F)

10 to 50C
(14 to 122F)

0.013 kPa abs


(0.0019 psi abs)
to flange rating pressure

0.94

1.07
1.07

*1: See figure 1-1, 1-2, 1-3, and 1-4 Working Pressure and Process Temperature.
*2: This ambient temperature is the transmitter ambient temperature.
*3: Approximate values at a temperature of 25C (77F)
Note: The differential pressure transmitter should be installed at least 600 mm below the high pressure (HP) process connection.

However, this value (600 mm) may be affected by ambient temperature, operating pressure, fill fluid or material of the
wetted diaphragm.

Contact YOKOGAWA when the transmitter can not be installed at least 600 mm below the HP process connection.

Transmitter ambient
temperature range
(for fill fluid code
A, B)

Process temperature
for fill fluid code B

Process temperature
for fill fluid code A
Flange max.
working
pressure
Atmospheric
pressure

100 (14.5)
Working
pressure
kPa abs
(psi abs)

Transmitter ambient
temperature range
(for fill fluid code D)

51 (7.4)

10(1.4)

2.7 (0.38)

2.7 (0.38)

1 (0.14)

1 (0.14)

0.1(0.014)
-50 0

50 100 150 200 250 300 350


Temperature (C)

0.1(0.014)
-50 0
F01E.ai

Figure 1-1. Working Pressure and Process


Temperature (Fill fluid: silicone oil for
general use)

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

Atmospheric
pressure

100 (14.5)
Working
pressure
kPa abs
(psi abs)

10(1.4)

Process temperature
for fill fluid code E
Process temperature
for fill fluid code D
Flange max.
working
pressure

50 100 150 200 250 300 350


Temperature (C)

F02E.ai

Figure 1-2. Working Pressure and Process


Temperature (Fill fluid: fluorinated oil for
oil-prohibited use and ethylene glycol for
low temperature use)

GS 01C31H01-11EN

Oct. 01, 2012-00

<<Contents>> <<Index>>

Transmitter ambient
temperature range

Process temperature
for fill fluid code 1
Flange max.
working
pressure
Atmospheric
pressure

100(14.5)
Working
pressure
kPa abs
(psi abs)

Supply & Load Requirements


(Output signal code D and J. Optional features
or approval codes may affect electrical
requirements.)
With 24 V DC supply, up to a 550 load can be
used. See graph below.

600
R=

10(1.4)

External
load
resistance

2.7(0.38)

E-10.5
0.0244

Digital
Communication
range
BRAIN and HART

250

1(0.14)

R ()

0.1(0.014)

25.2
10.5 16.6
Power supply voltage E (V DC)
0.013(0.0019)
0.01(0.0014)
-50 0

F03E.ai

Figure 2. Relationship Between Power Supply


Voltage and External Load Resistance

50 100 150 200 250 300 350


Temperature (C)

F12E.ai

Figure 1-3. Working Pressure and Process


Temperature (Fill fluid: silicone oil for
high temp. and high vacuum use)

Transmitter ambient
temperature range

Process temperature
for fill fluid code 4
Flange max.
working
pressure
Atmospheric
pressure

100(14.5)
Working
pressure
kPa abs
(psi abs)

10(1.4)

2.7(0.38)
1(0.14)

0.1(0.014)

0.013(0.0019)
0.01(0.0014)
-50 0

42

50 100 150 200 250 300 350


Temperature (C)

F13E.ai

Figure 1-4. Working Pressure and Process


Temperature (Fill fluid: silicone oil for
high vacuum use)

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

Supply Voltage
10.5 to 42 V DC for general use and flameproof type.
10.5 to 32 V DC for lightning protector (option code
/A).
10.5 to 30 V DC for intrinsically safe, type n, or nonincendive.
Minimum voltage limited at 16.6 V DC for digital
communications, BRAIN and HART
Load (Output signal code D and J)
0 to 1290 for operation
250 to 600 for digital communication
Communication Requirements
(Approval codes may affect electrical
requirements.)
BRAIN
Communication Distance
Up to 2 km (1.25 miles) when using CEV
polyethylene-insulated PVC-sheathed cables.
Communication distance varies depending on type of
cable used.
Load Capacitance
0.22 F or less
Load Inductance
3.3 mH or less
Input Impedance of communicating device
10 k or more at 2.4 kHz.
,
EMC Conformity Standards
EN61326-1 Class A, Table2 (For use in industrial
locations)
EN61326-2-3
European Pressure Equipment Directive 97/23/EC
Sound Engineering Practice

GS 01C31H01-11EN

Oct. 01, 2012-00

<<Contents>> <<Index>>

PHYSICAL SPECIFICATIONS
Process connections
See the following table.
Table 2. Flange size and rating
Process
connection style

Size

Flange

Adapter
connection type

1/2-inch
3/4-inch
1-inch

JIS 10K, 20K, 40K


ANSI Class 150, 300, 600
JPI Class 150, 300, 600

Flange
connection type

1/2-inch
3/4-inch
1-inch

JIS 10K, 20K, 40K


ANSI Class 150, 300, 600
JPI Class 150, 300, 600

Gasket Contact Surface


See the following table.

Add 1.5kg (3.3lb) for Amplifier housing code 2.

Table 3. Gasket contact surface


Flange
Wetted parts material code
1
Gasket contact Serration*
Surface
Flat (No serration)

Diaphragm seal section:


Capillary tube
316 SST
Protection tube
304 SST PVC-sheathed
(Max. operating temperature of PVC,100C (212F))
Fill fluid
See table 1.
In case of Adapter connection type
Stud bolt.... B7
Nut............. 304 SST
Weight
Inner diaphragm, adapter connection type: 8.8 kg
(19.4 lbs)
(1/2-inch ANSI Class150 flange, capillary length 5m;
without integral indicator and mounting bracket.)

JIS/JPI
SA, WA,
SD WD

ANSI
SA, WA,
SD WD

: Applicable, : Not applicable


*1: ANSI B16.5

Electrical Connections
See MODEL AND SUFFIX CODES.
Transmitter Mounting
2-inch pipe mounting
Wetted Parts Material
Diaphragm seal
Diaphragm and other wetted parts;
Refer to MODEL AND SUFFIX CODES.
Vent / Drain plugs
316 SST
Flange Material
Refer to MODEL AND SUFFIX CODES.
(It means the material of adapter or pipe with
flange.)
Gasket for transmitter side
316L SST with PTFE Teflon coating
Non-wetted Parts Material
Transmitter body section:
Cover flange
ASTM CF-8M
Cover flange bolting
B7 carbon steel, 316L SST or 660 SST
Housing
Low copper cast aluminum alloy with polyurethane,
deep sea moss green paint (Munsell 0.6GY3.1/2.0
or its equivalent) or ASTM CF-8M stainless steel
Degrees of Protection
IP66/IP67, NEMA4X
Cover O-rings
Buna-N, fluoro-rubber (optional)
Name plate and tag
316 SST

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

< Related Instruments>


Power Distributor: Refer to GS 01B04T01-02E or
GS 01B04T02-02E
BRAIN TERMINAL: Refer to GS 01C00A11-00E
< Reference >
1. Teflon; Trademark of E.I. DuPont de Nemours & Co.
2. Hastelloy; Trademark of Haynes International Inc.
3. HART; Trademark of the HART Communication
Foundation.
4. Foundation Fieldbus; Trademark of Fieldbus
Foundation.
5. DPharp EJA, Fieldmate; Trademark of Yokogawa
Electric Corporation.
Other company names and product names used in this
material are registered trademarks or trademarks of
their respective owners.

GS 01C31H01-11EN

Oct. 01, 2012-00

<<Contents>> <<Index>>

MODEL AND SUFFIX CODES


Instruction
The model and suffix codes for EJA118E consist of two parts; a transmitter body section (I) and a diaphragm seal
section (II). This specification sheet introduces these two parts separately. The transmitter body section is shown in
one table, and the diaphragm seal section specifications are listed according to the process connection style. First
select the model and suffix codes of transmitter body section and then continue on one of the diaphragm seal section.
EJA118E
I Transmitter body section

See Page 7

II Diaphragm seal section

Inner diaphragm,
Adapter connection type See Page 8
Inner diaphragm,
Flange connection type See Page 9
F04E.ai

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

Oct. 01, 2012-00

<<Contents>> <<Index>>

I. Transmitter body section

EJA118E
F05E.ai

Model
EJA118E

Suffix codes

Description
Diaphragm sealed differential pressure transmitter

Output signal

-D

4 to 20 mA DC with digital communication (BRAIN protocol)

-J

4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)*1

-F
M

Digital communication (FOUNDATION Fieldbus protocol,


refer to GS 01C31T02-01EN)
2.5 to 100 kPa (10 to 400 inH2O)

25 to 500 kPa (100 to 2000 inH2O)

Measurement span
(capsule)

Always S

Always C

Coverflange bolts and nuts


material
Installation
Amplifier housing

B7 carbon steel

316L SST

660 SST

-9

Horizontal piping type and left side high pressure

Cast aluminum alloy

Cast aluminum alloy with corrosion resistance properties *2

ASTM CF-8M Stainless Steel *3

Electrical connection

G 1/2 female, one electrical connection without blind plugs

1/2 NPT female, two electrical connections without blind plugs

M20 female, two electrical connections without blind plugs

G 1/2 female, two electrical connections with a blind plug *4

1/2 NPT female, two electrical connections with a blind plug *4

M20 female, two electrical connections with a blind plug

G1/2 female, two electrical connections and a 316 SST blind plug

1/2 NPT female, two electrical connections and a 316 SST blind plug

M20 female, two electrical connections and a 316 SST blind plug

Integral Indicator

Digital indicator

Digital indicator with the range setting switch *5

None

Mounting braket

*4

304 SST 2-inch pipe mounting, flat type (for horizontal piping)

316 SST 2-inch pipe mounting, flat type (for horizontal piping)

None

Diaphragm seal section

Continued on diaphragm seal section (II)

The marks indicate the most typical selection for each specification.
*1: HART 5 or HART 7 is selectable. Specify upon ordering.
*2: Not applicable for electrical connection code 0, 5, 7, 9 and A. Content rate of copper in the material is 0.03% or less and
content rate of iron is 0.15% or less.
*3: Not applicable for electrical connection code 0, 5, 7 and 9.
*4: Material of a blind plug is aluminum alloy or 304 SST.
*5: Not applicable for output signal code F.

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

Oct. 01, 2012-00

<<Contents>> <<Index>>

II. Diaphragm seal section (Inner Diaphragm, Adapter connection type)


EJA118E

6
7
1

F06E.ai

Model

Suffix codes

Description

EJA118E

Transmitter body section (I)

Process connection style

-A

Inner Diaphragm, Adapter connection type

Flange rating

Process connection size


(Process flange size)
Flange material*3
Gasket contact surface*1

J1

JIS 10K

J2

JIS 20K

J4

JIS 40K

A1

ANSI class 150

A2

ANSI class 300

P2 JPI class 300

A4

ANSI class 600*8

P4 JPI class 600*8

1/2 inch (15 mm)

3/4 inch (20 mm)

1 inch (25 mm)

Extension

316 SST (Adapter material)*4

Serration (for ANSI flange only)

Flat (no serration)

Wetted parts material*3

Flushing connection ring*2

P1 JPI class 150

[Diaphragm]

[Others]

SA

316L SST

316 SST (include Adapter)*4

WA

Hastelloy C-276 *5 #

316 SST (include Adapter)*4 #

None

None

Fill fluid*5

[Process
temperature]

[Ambient
temperature]

-A

For general use (silicone oil)

10 to 250C

10 to 60C

-B

For general use (silicone oil)

30 to 180C

15 to 60C

-D

For oil-prohibited use (fluorinated oil)*2

20 to 120C

10 to 60C

-E

For low temperature use (ethylene glycol)

50 to 100C

40 to 60C

-1

High temp. and high vacuum use (Silicone oil) 10 to 250C

10 to 50C

-4

High vacuum use (Silicone oil)

10 to 50C

Capillary connection

Back of diaphragm seal unit

Capillary treatment*6

Bundled capillary (1 m separated)

Standard

Capillary length*7

10 to 100C

1 m*6

6 6 m

2m

7 7 m

3m

8 8 m

4m

9 9 m

5m

A 10 m

Option codes and Tokuchu code

/ Optional specification and /Z

The marks indicate the most typical selection for each specification. Example: EJA118E-DMSCG-912EN-AA16E2SA00-BB15//Z
*1: See table 3 Gasket contact surface on page 5.
*2: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing
and dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
*3: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of
inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage
to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm
and the fill fluid can contaminate the users process fluids.

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium
hypochlorite, and high-temperature steam (150C [302F] or above). Contact Yokogawa for detailed information of the
wetted parts material.
*4: Forged version of the material may be used.
*5: Hastelloy C-276 or N10276.
*6: In case where capillary length code 1 (1 m) is selected, capillary treatment must be selected code 2 (None).
*7: In case of wetted parts material code WA (Hastelloy C), specify capillary length from 1 to 5m.
*8: In case where flange rating code A4 (ANSI class 600) or P4 (JPI class 600) is selected, It must be selected optional code
/HP (High pressure-proof structure).
The # marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please
refer to the latest standards for details. Selected materials also conform to NACE MR0103.

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

Oct. 01, 2012-00

<<Contents>> <<Index>>

II. Diaphragm seal section (Inner Diaphragm, Flange connection type)


EJA118E

6
7
1

F07E.ai

Model
EJA118E

Suffix codes

Transmitter body section (I)

Process connection style

-D

Inner Diaphragm, Flange connection type

Flange rating

J1

JIS 10K

J2

JIS 20K

J4

JIS 40K

A1

ANSI class 150

A2

ANSI class 300

A4

ANSI class 600*8

P1

JPI class 150

P2

JPI class 300

P4
Process connection size
(Process flange size)
Flange material*3

Gasket contact surface*1

Wetted parts material*3

Extension

1/2 inch (15 mm)

3/4 inch (20 mm)

1 inch (25 mm)

Capillary treatment*6
Capillary length*7

316 SST (Flange and Pipe material)*4

Serration (for ANSI flange only)

Flat (no serration)


[Diaphragm]
316L SST
Hastelloy C-276 *5 #

None

None

[Others]

316 SST *4
316 SST *4 #

[Process
temperature]

[Ambient
temperature]

-A

For general use (silicone oil)

10 to 250C

10 to 60C

-B

For general use (silicone oil)

30 to 180C

15 to 60C

20 to 120C

10 to 60C

Fill fluid

Capillary connection

JPI class 600*8

SD
WD
Flushing connection ring

Description

-D

For oil-prohibited use (fluorinated oil)*2

-E

For low temperature use (ethylene glycol) 50 to 100C

40 to 60C

-1

High temp. and high vacuum use (Silicone oil) 10 to 250C

10 to 50C

-4

High vacuum use (Silicone oil)

10 to 50C

Back of diaphragm seal unit

10 to 100C

Bundled capillary (1 m separated)

Standard

1 m*6

6 6 m

2m

7 7 m

3m

8 8 m

4m

9 9 m

5m

A 10 m

Option codes and Tokuchu code

/ Optional specification and /Z

The marks indicate the most typical selection for each specification. Example: EJA118E-DMSCG-912EN-DA16D2SD00-BB15//Z
*1: See table 3 Gasket contact surface on page 5.
*2: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing
and dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
*3: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of
inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage
to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm
and the fill fluid can contaminate the users process fluids.

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium
hypochlorite, and high-temperature steam (150C [302F] or above). Contact Yokogawa for detailed information of the
wetted parts material.
*4: Forged version of the material may be used.
*5: Hastelloy C-276 or N10276.
*6: In case where capillary length code 1 (1 m) is selected, capillary treatment must be selected code 2 (None).
*7: In case of wetted parts material code WD (Hastelloy C), specify capillary length from 1 to 5m.
*8: In case where flange rating code A4 (ANSI class 600) or P4 (JPI class 600) is selected, It must be selected optional code
/HP (High pressure-proof structure).
The # marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please
refer to the latest standards for details. Selected materials also conform to NACE MR0103.

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

Oct. 01, 2012-00

10

<<Contents>> <<Index>>

OPTIONAL SPECIFICATIONS (For Explosion Protected type)


Item
Factory Mutual
(FM)

ATEX

Description
FM Explosionproof Approval *1
Applicable Standard: FM3600, FM3615, FM3810, ANSI/NEMA 250
Explosionproof for Class I, Division 1, Groups B, C and D, Dust-ignitionproof for Class II/III, Division 1,
Groups E, F and G, in Hazardous locations, indoors and outdoors (NEMA 4X)
FACTORY SEALED, CONDUIT SEAL NOT REQUIRED.
Temperature class: T6, Amb. Temp.: 40 to 60C (40 to 140F) *2
FM Intrinsically safe Approval *1
Applicable Standard: FM3600, FM3610, FM3611, FM3810
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,
Groups E, F & G and Class III, Division 1, Class I, Zone 0, in Hazardous Locations, AEx ia IIC
Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,
Groups F & G, Class I, Zone 2, Group IIC, in Hazardous Locations
Enclosure: NEMA 4X, Temp. Class: T4, Amb. Temp.: 60 to 60C (75 to 140F) *2
Intrinsically Safe Apparatus Parameters
[Groups A, B, C, D, E, F and G] Vmax=30 V, Imax=200 mA, Pmax=1 W, Ci=6 nF, Li=0 H
[Groups C, D, E, F and G] Vmax=30 V, Imax=225 mA, Pmax=1 W, Ci=6 nF, Li=0 H
Combined FF1 and FS1 *1
ATEX Flameproof Approval *1
Applicable Standard: EN 60079-0, EN 60079-1, EN 60079-31
Certificate: KEMA 07ATEX0109 X
II 2G, 2D Ex d IIC T6...T4 Gb, Ex tb IIIC T85C Db IP6X
Degree of protection: IP66/IP67
Amb. Temp. (Tamb) for gas-proof :
T4; 50 to 75C (58 to 167F), T5; 50 to 80C (58 to 176F), T6; 50 to 75C (58 to 167F)
Max. process Temp. for gas-proof (Tp): T4; 120C (248F), T5; 100C (212F), T6; 85C (185F)
Max. surface Temp. for dust-proof: T85C (Tamb: 30 to 75C, Tp: 85C) *2
ATEX Intrinsically safe Approval *1
Applicable Standard: EN 60079-0, EN 60079-11, EN 60079-26, EN 61241-11
Certificate: DEKRA 11ATEX0228 X
II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85C T100C T120C Db
Degree of protection: IP66/IP67
Amb. Temp. (Tamb) for EPL Ga: 50 to 60C (58 to 140F)
Maximum Process Temp. (Tp) for EPL Ga:120C
Electrical data: Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 H
Amb. Temp. for EPL Db: 30 to 60C *2
Max. surface Temp. for EPL Db: T85C (Tp: 80C), T100C (Tp: 100C), T120C (Tp: 120C)
Combined KF22, KS21 and Type n *1
Type n
Applicable Standard: EN 60079-0, EN 60079-15
II 3G Ex nL IIC T4 Gc, Amb. Temp.: 30 to 60C (22 to 140F) *2
Ui=30 V DC, Ci=10 nF, Li=0 H

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

Code

FF1

FS1

FU1

KF22

KS21

KU22

Oct. 01, 2012-00

11

<<Contents>> <<Index>>
Item
Canadian
Standards
Association
(CSA)

IECEx

*1:
*2:

Description
CSA Explosionproof Approval *1
Certificate: 2014354
Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.0.5, C22.2 No.25, C22.2 No.30,
C22.2 No.94, C22.2 No.60079-0, C22.2 No.60079-1, C22.2 No.61010-1-04
Explosion-proof for Class I, Groups B, C and D.
Dustignition-proof for Class II/III, Groups E, F and G.
When installed in Division 2, SEAL NOT REQUIRED Enclosure: NEMA 4X, Temp. Code: T6...T4
Ex d IIC T6...T4 Enclosure: IP66/IP67
Max.Process Temp.: T4;120C(248F), T5;100C(212F), T6; 85C(185F)
Amb.Temp.: 50 to 75C(58 to 167F) for T4, 50 to 80C(58 to 176F) for T5,
50 to 75C(58 to 167F) for T6 *2
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
CSA Intrinsically safe Approval *1
Certificate: 1606623
[For CSA C22.2]
Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.25, C22.2 No.94, C22.2 No.157,
C22.2 No.213, C22.2 No.61010-1
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G,
Class III, Division 1, Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2,
Groups F & G, Class III, Division 1
Enclosure: NEMA 4X, Temp. Code: T4 Amb. Temp.: 50 to 60C(58 to 140F) *2
Electrical Parameters: [Intrinsically Safe] Vmax=30V, Imax=200mA, Pmax=0.9W, Ci=10nF, Li=0 H
[Nonincendive] Vmax=30V, Ci=10nF, Li=0 H
[For CSA E60079]
Applicable Standard: CAN/CSA E60079-0, CAN/CSA E60079-11, CAN/CSA E60079-15,
IEC 60529:2001-02
Ex ia IIC T4, Ex nL IIC T4 Enclosure: IP66/IP67
Amb. Temp.: 50 to 60C(58 to 140F) *2, Max. Process Temp.: 120C(248F)
Electrical Parameters: [Ex ia] Ui=30V, Ii=200mA, Pi=0.9W, Ci=10nF, Li=0 H

[Ex nL] Ui=30V, Ci=10nF, Li=0 H
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
Combined CF1 and CS1 *1
IECEx Flameproof Approval *1
Applicable Standard: IEC 60079-0:2004, IEC60079-1:2003
Certificate: IECEx CSA 07.0008
Flameproof for Zone 1, Ex d IIC T6...T4 Enclosure: IP66/IP67
Max.Process Temp.: T4;120C(248F), T5;100C(212F), T6; 85C(185F)
Amb.Temp.: 50 to 75C(58 to 167F) for T4, 50 to 80C(58 to 176F) for T5,
50 to 75C(58 to 167F) for T6 *2

Code

CF1

SF2

Applicable for Electrical connection code 2, 4, 7, 9, C and D.


Lower limit of ambient temperature is 15C (5F) when /HE is specified.

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

Oct. 01, 2012-00

12

<<Contents>> <<Index>>

OPTIONAL SPECIFICATIONS
Item
Color change

Amplifier cover only*1

Coating change

Anti-corrosion coating*1*2

X2

316 SST zero-adjustment screw and setscrews*3

HC

Fluoro-rubber O-ring

All O-rings of amplifier housing. Lower limit of ambient temperature: 15C (5F)

HE

Lightning protector

Transmitter power supply voltage: 10.5 to 32 V DC ( 10.5 to 30 V DC for intrinsically safe


type.)
Allowable current: Max. 6000 A ( 140 s ), Repeating 1000 A ( 140 s ) 100 times
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5

Oil-prohibited use

Degrease cleansing treatment

K1

Oil-prohibited use
with dehydrating treatment

Degrease cleansing treatment and dehydrating treatment

K5

Painting

Description

Code
P
PR

Amplifier cover and terminal cover, Munsell 7.5 R4/14


316 SST exterior parts

Calibration units

*4

P calibration (psi unit)

D1

(See table for Span and


Range Limits.)

bar calibration (bar unit)


M calibration (kgf/cm2 unit)

D3
D4

Operating temperature correction *5

Adjusting range : 80C to Maximum temperature of specified fill fluid

Capillary without PVC sheaths

When ambient temperature exceeds 100C, or use of PVC is prohibited

Output limits
and failure operation *6

Failure alarm down-scale : Output status at CPU failure and hardware error is 5%,
3.2mA DC or less.

C1

NAMUR NE43 Compliant


Output signal limits: 3.8 mA to
20.5 mA

Failure alarm down-scale : Output status at CPU failure


and hardware error is 5%, 3.2 mA DC or less.

C2

Failure alarm up-scale : Output status at CPU failure and


hardware error is 110%, 21.6 mA or more.

C3

Gold-plated diaphragm

Inside of isolating diaphragms (fill fluid side) are gold plated, effective for hydrogen
permeation.

A1

Wired tag plate

316 SST tag plate wired onto transmitter

N4

Data configuration at factory *7

Material certificate

Data configuration for HART communication type

Software damping, Descriptor,


Message

Data configuration for BRAIN communication type

Software damping

Adapter (Flange), Block


Adapter (Flange), Block, Bolt for Block,
Stud bolt and nut, Bolt and nut for cover flange
Flange, Base, Block, Pipe
Flange, Base, Block, Pipe, Bolt for block,
Bolt and nut for cover flange

*1:
*2:
*3:
*4:
*5:
*6:
*7:

Adapter connection type

Flange connection type

CA
CB
M2A
M8A
M2D
M8D

Not applicable for amplifier housing code 2 and 3.


Not applicable with color change option.
316 or 316L SST. The specification is included in amplifier housing code 2.
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option code D1,
D3, and D4.
Specify the process operating temperature for zero correction. Example: Zero correction by process temperature 90C.
Applicable for output signal code D and J. The hardware error indicates faulty amplifier or capsule.
Also see Ordering Information.

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

Oct. 01, 2012-00

13

<<Contents>> <<Index>>
Item
Pressure test/Leak test
Certificate *1

Long Vent

(Flange rating)

Description
(Test pressure)

JIS 10K

2 MPa (290 psi)

JIS 20K

5 MPa (720 psi)

JIS 40K

10 MPa (1450 psi)

ANSI/JPI Class 150

3 MPa (430 psi)

ANSI/JPI Class 300

8 MPa (1160 psi)

ANSI/JPI Class 600

16 MPa (2300 psi)

Code
T51
T54

Nitrogen (N2) Gas *2


Retention time:
one minute

T57
T52
T56
T58

For inner diaphragm use only.


Total length: 119 mm (standard: 34 mm); Total length when combining with option code K1, K2,
K5, and K6: 130 mm. Material: 316 SST

High pressure-proof structure*3 High pressure-proof structure for ANSI/JPI class 600 flange.
*1:
*2:
*3:

U2
HP

The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D4.
Pure nitrogen gas is used for oil-prohibited use (option code K1 and K5.)
In case where flange rating code A4 (ANSI class 600) or P4 (JPI class 600) is selected, optional code /HP (High pressureproof structure) must be selected.

DIMENSIONS
Transmitter body section
Unit: mm (Approx.: inch)

83(3.27)

Terminal side

129(5.08)

Ground terminal

70
(2.76)

39
12
(0.47) (1.54)

Zero adjustment

175(6.89)
47

110(4.33)

Conduit connection

89(3.50)

High pressure side

(1.85)

315(12.40)

Electrical connection
for code 5 and 9.

Integral indicator
(optional)

95(3.74)

54
(2.13)

124(4.88)

6
(0.24)

137(5.39)

78(3.07)

External indicator
conduit connection
(optional)

Low pressure side

Shrouding bolt
(for flame-proof type)

Mounting bracket
(flat-type, optional)

2-inch pipe
(O.D. 60.5 mm)
F08E.ai

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

Oct. 01, 2012-00

14

<<Contents>> <<Index>>

<Diaphragm seal section>


Adapter connection type
Unit: mm (Approx.: inch)

n-S
g
f
T

Drain
Vent plug

m*3
m+85(3.35)*4

Drain
Vent plug

Stud Bolt*1
(Nut included)

Process

With Long Vent (Option: /U2)

High Pressure
Side

106
(4.17)

Low Pressure
Side

Process Flange Size: 1/2 inch(15mm)


Flange rating
JIS 10K
JIS 20K
JIS 40K
ANSI class 150
ANSI class 300
ANSI class 600
JPI class 150
JPI class 300
JPI class 600

C*5

95(3.74)
95(3.74)
115(4.53)
88.9(3.50)
95.3(3.75)
95.3(3.75)
89(3.50)
95(3.74)
95(3.74)

70(2.76)
70(2.76)
80(3.15)
60.5(2.38)
66.5(2.62)
66.5(2.62)
60.5(2.38)
66.5(2.62)
66.5(2.62)

51(2.01)
51(2.01)
55(2.17)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)

52(2.05)
52(2.05)
52(2.05)
52(2.05)
52(2.05)
62(2.44)
52(2.05)
52(2.05)
62(2.44)

1(0.04)
72(2.83)
1(0.04)
72(2.83)
1(0.04) 79.5(3.13)
1.6(0.06) 72(2.83)
1.6(0.06) 72(2.83)
6.4(0.25) 72(2.83)
1.6(0.06) 72(2.83)
1.6(0.06) 72(2.83)
6.4(0.25) 72(2.83)

4
4
4
4
4
4
4
4
4

M12 1.75
M12 1.75
M16 2.0
1/2-13UNC
1/2-13UNC
1/2-13UNC
1/2-13UNC
1/2-13UNC
1/2-13UNC

L
(Reference)

43(1.69)
43(1.69)
57(2.24)
44(1.73)
44(1.73)
59(2.32)
44(1.73)
44(1.73)
59(2.32)

Process Flange Size: 3/4 inch(20mm)


Flange rating
JIS 10K
JIS 20K
JIS 40K
ANSI class 150
ANSI class 300
ANSI class 600
JPI class 150
JPI class 300
JPI class 600

C*5

100(3.94)
100(3.94)
120(4.72)
98.6(3.88)
117.3(4.62)
117.3(4.62)
99(3.90)
117(4.61)
117(4.61)

75(2.95)
75(2.95)
85(3.35)
69.9(2.75)
82.6(3.25)
82.6(3.25)
69.8(2.75)
82.6(3.25)
82.6(3.25)

56(2.20)
56(2.20)
60(2.36)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)

52(2.05)
52(2.05)
52(2.05)
52(2.05)
52(2.05)
62(2.44)
52(2.05)
52(2.05)
62(2.44)

1(0.04)
1(0.04)
1(0.04)
1.6(0.06)
1.6(0.06)
6.4(0.25)
1.6(0.06)
1.6(0.06)
6.4(0.25)

72(2.83)
72(2.83)
82(3.23)
72(2.83)
80.7(3.18)
80.7(3.18)
72(2.83)
80.7(3.18)
80.7(3.18)

4
4
4
4
4
4
4
4
4

M12 1.75
M12 1.75
M16 2.0
1/2-13UNC
5/8-11UNC
5/8-11UNC
1/2-13UNC
5/8-11UNC
5/8-11UNC

4
4
4
4
4
4
4
4
4

M16 2.0
M16 2.0
M16 2.0
1/2-13UNC
5/8-11UNC
5/8-11UNC
1/2-13UNC
5/8-11UNC
5/8-11UNC

Capillary Length

A*2

L
(Reference)

43(1.69)
43(1.69)
57(2.24)
44(1.73)
51(2.01)
67(2.64)
44(1.73)
51(2.01)
67(2.64)

Process Flange Size: 1 inch(25mm)


Flange rating
JIS 10K
JIS 20K
JIS 40K
ANSI class 150
ANSI class 300
ANSI class 600
JPI class 150
JPI class 300
JPI class 600

C*5

125(4.92)
125(4.92)
130(5.12)
108(4.25)
124(4.88)
124(4.88)
108(4.25)
124(4.88)
124(4.88)

90(3.54)
90(3.54)
95(3.74)
79.2(3.12)
88.9(3.50)
88.9(3.50)
79.2(3.12)
88.9(3.50)
88.9(3.50)

67(2.64)
67(2.64)
70(2.76)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)

52(2.05)
52(2.05)
52(2.05)
52(2.05)
52(2.05)
62(2.44)
52(2.05)
52(2.05)
62(2.44)

1(0.04) 84.5(3.33)
1(0.04) 84.5(3.33)
1(0.04)
87(3.43)
1.6(0.06) 76(2.99)
1.6(0.06) 84(3.31)
6.4(0.25) 84(3.31)
1.6(0.06) 76(2.99)
1.6(0.06) 84(3.31)
6.4(0.25) 84(3.31)

L
(Reference)

57(2.24)
57(2.24)
57(2.24)
44(1.73)
51(2.01)
67(2.64)
44(1.73)
51(2.01)
67(2.64)

*1: Stud bolts and nuts are attached for 2 n pcs.


*2: When selecting Capillary treatment code 1, the capillaries are bundled at A while having 1m separated capillaries for remote seals.
*3: In case of oil-prohibited use or oil-prohibited use with dehydrating treatment, 15mm added.
*4: In case of oil-prohibited use or oil-prohibited use with dehydrating treatment, 11mm added.
*5: This value is the same as flange standards. Actual value might be added 1mm(0.04inch) because the commercial gaskets can be used.

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

GS 01C31H01-11EN

F09E.ai

Oct. 01, 2012-00

15

<<Contents>> <<Index>>

Flange connection type

Process

108
(4.25)

With Long Vent (Option: /U2)

n-h

Unit: mm (Approx.: inch)

Drain
Vent plug
77.5*2
(3.05)
106
(4.17)

162.5*3
(6.40)

*1: When selecting Capillary treatment code 1,


the capillaries are bundled at A while having
1m separated capillaries for remote seals.
*2: In case of oil-prohibited use or oil-prohibited
use with dehydrating treatment, 15mm added.
*3: In case of oil-prohibited use or oil-prohibited
use with dehydrating treatment, 11mm added.

High Pressure
Side

Capillary Length

Low Pressure
Side

A*1

Process Flange Size: 1/2 inch(15mm)


Flange rating
JIS 10K
JIS 20K
JIS 40K
ANSI class 150
ANSI class 300
ANSI class 600
JPI class 150
JPI class 300
JPI class 600

D
95(3.74)
95(3.74)
115(4.53)
88.9(3.50)
95.3(3.75)
95.3(3.75)
89(3.50)
95(3.74)
95(3.74)

C
70(2.76)
70(2.76)
80(3.15)
60.5(2.38)
66.5(2.62)
66.5(2.62)
60.5(2.38)
66.5(2.62)
66.5(2.62)

g
51(2.01)
51(2.01)
55(2.17)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)
35.1(1.38)

T
39(1.54)
39(1.54)
39(1.54)
39(1.54)
39(1.54)
60(2.36)
39(1.54)
39(1.54)
60(2.36)

t
12(0.47)
14(0.55)
20(0.79)
11.2(0.44)
14.3(0.56)
14.3(0.56)
11.2(0.44)
14.3(0.56)
14.3(0.56)

f
1(0.04)
1(0.04)
1(0.04)
1.6(0.06)
1.6(0.06)
6.4(0.25)
1.6(0.06)
1.6(0.06)
6.4(0.25)

n
4
4
4
4
4
4
4
4
4

h
15(0.59)
15(0.59)
19(0.75)
15.7(0.62)
15.7(0.62)
15.7(0.62)
16(0.63)
16(0.63)
16(0.63)

g
56(2.20)
56(2.20)
60(2.36)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)
42.9(1.69)

T
39(1.54)
39(1.54)
39(1.54)
39(1.54)
39(1.54)
60(2.36)
39(1.54)
39(1.54)
60(2.36)

t
14(0.55)
16(0.63)
20(0.79)
12.7(0.50)
15.8(0.62)
15.8(0.62)
12.7(0.50)
15.8(0.62)
15.8(0.62)

f
1(0.04)
1(0.04)
1(0.04)
1.6(0.06)
1.6(0.06)
6.4(0.25)
1.6(0.06)
1.6(0.06)
6.4(0.25)

n
4
4
4
4
4
4
4
4
4

h
15(0.59)
15(0.59)
19(0.75)
15.7(0.62)
19.1(0.75)
19.1(0.75)
16(0.63)
19(0.75)
19(0.75)

g
67(2.64)
67(2.64)
70(2.76)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)
50.8(2.00)

T
39(1.54)
39(1.54)
39(1.54)
39(1.54)
39(1.54)
60(2.36)
39(1.54)
39(1.54)
60(2.36)

t
14(0.55)
16(0.63)
22(0.87)
14.3(0.56)
17.6(0.69)
17.6(0.69)
14.3(0.56)
17.6(0.69)
17.6(0.69)

f
1(0.04)
1(0.04)
1(0.04)
1.6(0.06)
1.6(0.06)
6.4(0.25)
1.6(0.06)
1.6(0.06)
6.4(0.25)

n
4
4
4
4
4
4
4
4
4

h
19(0.75)
19(0.75)
19(0.75)
15.7(0.62)
19.1(0.75)
19.1(0.75)
16(0.63)
19(0.75)
19(0.75)

Process Flange Size: 3/4 inch(20mm)


Flange rating
JIS 10K
JIS 20K
JIS 40K
ANSI class 150
ANSI class 300
ANSI class 600
JPI class 150
JPI class 300
JPI class 600

D
100(3.94)
100(3.94)
120(4.72)
98.6(3.88)
117.3(4.62)
117.3(4.62)
99(3.90)
117(4.61)
117(4.61)

C
75(2.95)
75(2.95)
85(3.35)
69.9(2.75)
82.6(3.25)
82.6(3.25)
69.8(2.75)
82.6(3.25)
82.6(3.25)

Process Flange Size: 1 inch(25mm)


Flange rating
JIS 10K
JIS 20K
JIS 40K
ANSI class 150
ANSI class 300
ANSI class 600
JPI class 150
JPI class 300
JPI class 600

D
125(4.92)
125(4.92)
130(5.12)
108(4.25)
124(4.88)
124(4.88)
108(4.25)
124(4.88)
124(4.88)

C
90(3.54)
90(3.54)
95(3.74)
79.2(3.12)
88.9(3.50)
88.9(3.50)
79.2(3.12)
88.9(3.50)
88.9(3.50)

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

F10E.ai

GS 01C31H01-11EN

Oct. 01, 2012-00

16

<<Contents>> <<Index>>

Terminal Wiring

Terminal Configuration
Communication
terminals (BT200 etc.)
connection hook

Check meter
connection hook*1*2

SUPPLY
CHECK

Power supply and output terminal


External indicator (ammeter) terminal*1*2
Ground terminal

SUPPLY +
SUPPLY

CHECK +

*1: When using an external indicator or check meter, the internal


resistance must be 10 or less.
*2: Not available for fieldbus communication type.

CHECK

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation

F11E.ai

GS 01C31H01-11EN

Oct. 01, 2012-00

17

<<Contents>> <<Index>>

< Ordering Information >


Specify the following when ordering
1. Model, suffix codes, and option codes
2. Calibration range and units:
1) Calibration range can be specified with range
value specifications up to 5 digits (excluding any
decimal point) for low or high range limits within
the range of -32000 to 32000. When reverse range
is designated, specify LRV as greater than URV.
When square root output mode is specified, LRV
must be 0(zero).
2) Specify only one unit from the table, Factory
setting.
3. Select linear or square root for output mode and
display mode.
Note: If not specified, the instrument is shipped set for
linear mode.

4. Display scale and units (for transmitters equipped


with the integral indicator only)
Specify either 0 to 100 % or Range and Unit for
engineering units scale:
Scale range can be specified with range limit
specifications up to 5 digits (excluding any decimal
point) for low or high range limits within the range of
-32000 to 32000. Unit display consists of 6-digit,
therefore, if the specified scaling unit excluding / is
longer than 6-characters , the first 6 characters will
be displayed on the unit display.
5. HART PROTOCOL
When output signal code is J, specify the HART
protocol revision 5 or 7.
6. TAG NO (if required)
Specified characters (up to 16 characters) are
engraved on the stainless steel tag plate fixed on
the housing.
7. SOFTWARE TAG (for HART only. if required)
Specified characters (up to 32 characters) are set
as Tag (the first 8 characters) and Long tag*1
(32 characters) in the amplifier memory. Use
alphanumeric capital letters.
When the SOFTWARE TAG is not specified,
specified TAG NO is set as Tag (the first 8
characters) and Long tag*1 (16 characters) in the
amplifier memory.
*1:

< Factory Setting >


Tag Number

As specified in order

Software
damping *1

2.00 s or as specified in order

Output mode

Linear unless otherwise specified in order

Calibration
range lower
range value

As specified in order

Calibration
range upper
range value

As specified in order

Calibration
range units

Selected from mmH2O, mmH2O(68F),


mmAq*2, mmWG*2, mmHg, Pa, hPa*2, kPa,
MPa, mbar, bar, gf/cm2, kgf/cm2, inH2O,
inH2O(68F), inHg, ftH2O, ftH2O(68F) or psi.
(Only one unit can be specified)

Display setting

Designated differential pressure value


specified in order. (% or user scaled value.)
Display mode 'Linear' or 'Square root' is also
as specified in order.

Static pressure '0 to 25 MPa' for M and H capsule, absolute


display range
value. Measuring low pressure side.
*1:
*2:

To specify these items at factory, /CA or /CB


option is required.
Not available for HART protocol type.

< Material Cross Reference >


ASTM

JIS

316

SUS316

F316

SUSF316

316L
F316L

SUS316L

304

SUS304

F304

SUSF304

660

SUH660

B7

SNB7

CF-8M

SCS14A

SUSF316L

Applicable only when HART 7 is selected.

8. Other factory configurations (if required)


Specifying option code /CA or /CB will allow further
configuration at factory. Following are configurable
items and setting range.
[/CA : For HART communication type]
1) Descriptor(upto 16 characters)
2) Message (upto 30 characters)
3) Software damping (0.00 to 100.00 s)
[/CB : For BRAIN communication type]
1) Software damping (0.00 to 100.00 s)
9. Process fluid temperature for zero compensation
(When /R is specified)

All Rights Reserved. Copyright 2012, Yokogawa Electric Corporation


Subject to change without notice.

GS 01C31H01-11EN