Simple Distillation Model
Introduction
This spreadsheet is a simple distillation that cna be used to investigate the effect of design parameters on
distillation performance. The calculation method uses a number of simplifying assumptions and should not be
used in detailed design
The spreadsheet is split into the following sections
- A "How to Use This Calculation" Worksheet
- The Distillation Worksheet itself - marked "Calculation"
- A Theory Worksheet which presents the equations used in the calculation.
It is recommended that the user first reads the 'How to Use These Calculation' worksheet before starting a
calculation.
Revision
Rev. 1
Initial issue
22-Sep-11
Disclaimer: This calculation provides a simplified model of a distillation column for preliminary design purposes only. We cannot be
held responsible for its use. As with all areas of process engineering, calculations should be checked by a competent engineer.
www.myChemE.com
Calculation Title:
Press CRTL+Q to run model
Condenser
Relative Volatility (Alpha)
2.4
Total number of
Trays
10
Feed
Feed Flow
Feed Quality
Type of Condenser
Partial Condenser
Reflux Ratio
(Mole Basis)
0.5
Distillate
Total Molar Flowrate
100.0
kmol/h
Mole fraction Benzene
0.70
Mole fraction Toluene
0.30
100.0 kmol/h
Vapour Feed
Feed Composition
Component 1
Benzene
Component 1 Mole Fraction
0.70
Component 2
Toluene
Component 2 Mole Fraction
0.30
Feed Tray
6
ERROR Messages
Bottom Product
Total Molar Flowrate
0.0
kmol/h
Mole fraction Benzene
0.00
Mole fraction Toluene
1.00
Condenser
Disclaimer: This calculation is a simplified model of a distillation column for preliminary design. We cannot be held
responsible for its use. As with all areas of process engineering, calculations should be checked by a competent engineer.
www.myChemE.com
Revision 1
INTRODUCTION
This spreadsheet is a simplified model of a distilation which can be used to study the impact of design parameters
on distillation performance. It is for use as a preliminary design tool only and should not be used to for the detailed
specification of a distillation column.
The simplified model is based on a number of key assumptions
1 It is a binary system - i.e. there are only two components in the mixture.
2 The two components are ideal, with a constant relative volatility. There is a constant molar overflow in the
column as the two components have the same molar latent heat of evaporation and there are no heat losses
or heat of mixing.
3 The plates are 100% efficient - each plate can be considered as one theoretical plate.
The assumptions underpinning the model are discussed in more detail in the Theory Worksheet.
2.0
2.1
Colour Coding
The following colour coding is used:
Boxes shaded light green, with text in bold, require a user input.
Boxes shaded light blue give a calculated output. An error message is displayed if the user
attempts to overwrite the calculated value.
2.2
Calculation Title
The spreadsheet leaves space to add a Calculation Title at the top. Although ths space is not strictly
necessary, it helps describe the calculation - this can be invaluable if it is to be checked by another
engineer.
2.3
Number of Trays
The user enters the total number of trays (or plates) in the column. It should be noted that each tray is
assumed to 100% efficient (see theory worksheet for details). The column must have at least one tray and
a maximum of ten.
2.4
Feed Tray
The user enters the position of the feed tray - i.e. the tray at which the feed enters the column. The trays
are counted from the bottom. In other words Tray 1 is at the bottom just above the reboiler and Tray 2 is
above Tray 1. So if the column is specified with a total of 6 trays and the feed tray is number 3, the column
will 3 trays below the feed tray, followed by the feed tray and then a further 2 trays above the feed tray.
The number of the feed tray cannot be greater than the total number of trays - the spreadsheet will display
an error message if the user tries to do this.
2.5
Reflux Ratio
The user must specify the Reflux Ratio on a molar basis. The Reflux Ratio is the liquid molar flow returning
to the column divided by the distillate molar flow. As it is a fraction of the total distillate flow, it must have a
value between zero and 1. If the reflux ratio is set to zero, there is no liquid returned to the top of the
column. This will mean that the section of the column above the feed does not achieve any separation.
Separation is maximised by setting the reflux ratio to 1, however this means that no distillate product is
collected. See the Theory Worksheet for more information.
Disclaimer: This calculation is a simplified model of a distillation column for preliminary design. We cannot be held responsible for its use. As with all areas of process
engineering, calculations should be checked by a competent engineer.
www.myChemE.com
Revision 1
Condenser Type
The user must specify the type of condenser. There are two options: Full Condenser or Partial Condenser.
If the Full Condenser option is selected, all of the vapour leaving the top tray is condensed. If the Partial
Condenser option is selected, the distillate product is retrieved as a vapour while the condensate is
returned to the column as a liquid. Hence, a partial condenser provides an additional separation stage.
The differencies between the two options are discussed in more detail in the Theory Worksheet.
2.6
2.7
2.8
Feed Flowrate
The user enters the total molar flowrate, in kmol/h. This is the molar flow for both component 1 and 2.
2.9
3.0
Disclaimer: This calculation is a simplified model of a distillation column for preliminary design. We cannot be held responsible for its use. As with all areas of process
engineering, calculations should be checked by a competent engineer.
www.myChemE.com
Revision 1
ERROR MESSAGES
The spreadsheet can display a number of error messages.
Many of the input cells are limited to certain values. For example, the component mole fractions must be
between 0 and 1. If the user attempts to input a value outside the acceptable range, the spreadsheet will
alert the user.
When the user first inputs values into the spreadsheet, an error message will be displayed that the
calculation has not converged. To converge the calculation, activate the macro (CTRL+Q).
The spreadsheet will also alert the user if parts of the column have a vapour or liquid flow below zero. If
this occurs, the user should adjust one, or more, of the following: feed quality, reflux ratio, distillate molar
flowrate.
Finally, the spreadsheet will warn the user if the Distillate flow is greater than the Feed flow - a situation
which is clearly not feasible.
Disclaimer: This calculation is a simplified model of a distillation column for preliminary design. We cannot be held responsible for its use. As with all areas of process
engineering, calculations should be checked by a competent engineer.
www.myChemE.com
Revision 1
CALCULATION THEORY
1.0
INTRODUCTION
This spreadsheet is a simplified model of a distilation which can be used to study the impact of design parameters
on distillation performance. It is for use as a preliminary design tool only and should not be used to for the detailed
specification of a distillation column.
2.0
3.0
The overall column mass balance is calculated by the model by splitting the column into two parts:
i. The Rectifying (Top) Section of the Distillation Column - this is the part of the distillation column above the
feed plate, including the condenser.
ii. The Enriching (Bottom) Section of the Distillation Column - this is the part of the distillation column below
the feed plate, including the reboiler.
3.1
Disclaimer: This calculation is a simplified model of a distillation column for preliminary design. We cannot be held responsible
for its use. As with all areas of process engineering, calculations should be checked by a competent engineer.
www.myChemE.com
Revision 1
The reflux flow sets the liquid flow down the Rectifying Section of the Column.
Equation (1)
Where:
Reflux Flow
L_Rectifying
D
R
Reflux molar flow returning to the column from the condenser, kmol/h
Liquid molar flow down the Rectifying Section of the Column, kmol/h
Distillate molar flow leaving the column as product, kmol/h
Molar Reflux Ratio (Dimensionless)
The vapour flow up the Rectifying Section of the column is set by the vapour flow up the stripping section plus the
vapour fraction of the feed flow into the column.
Equation (2)
Where:
V_Rectifying
F
Quality
V_Stripping
Vapour molar flow down the Rectifying Section of the Column, kmol/h
Feed molar flow into the Column, kmol/h
Feed Quality (Dimensionless)
Vapour molar flow down the Stripping Section of the Column, kmol/h
The feed quality is set by the user when they define the feed. If a liquid feed is specified, there is no feed
contribution to the vapour flow in the rectifying section of the column (Quality = 1). If a vapour feed is specified,
all the feed flows up the rectifying section (Quality =0). If a mixed feed is specified, half of the feed flows up the
rectifying section of the column (Quality = 0.5).
3.2
Disclaimer: This calculation is a simplified model of a distillation column for preliminary design. We cannot be held responsible
for its use. As with all areas of process engineering, calculations should be checked by a competent engineer.
www.myChemE.com
Revision 1
As the Feed flow and Distillate flow is set by the user, the Bottom product flow, B, (in kmol/h) can be calculated:
B= F-D
Equation (3)
The liquid flow up the Stripping Section of the column is set by the liquid flow down the rectifying section plus the
liquid fraction of the feed flow into the column.
Equation (4)
Where:
L_Stripping - Liquid molar flow down the Stripping Section of the Column, kmol/h
The vapour flow up the distillation column is the quantity of vapour generated by the reboiler. In the mass balance
it is the difference between the liquid flow down the stripping section and the bottom product.
V_Stripping = L_Stripping - B
3.3
Equation (5)
Having established the overall vapour and liquid flows within the column, the spreadsheet performs a tray
by tray component molar balance. This is an iterative calculation - hence the need for a macro. As there are
only two components, calculating the mole fraction of one component fixes the other. The following approach is
followed for each stage
Disclaimer: This calculation is a simplified model of a distillation column for preliminary design. We cannot be held responsible
for its use. As with all areas of process engineering, calculations should be checked by a competent engineer.
www.myChemE.com
Revision 1
y =
.x
x]
Equation (6)
3. Perform a molar balance for component 1 over each the stage. This is a calculation of the molar flow
entering and leaving the stage. For the feed tray, the molar balance considers the component feed flow
onto the tray.
4 If the molar flows onto and off the tray do not balance, the macro re-adjusts the tray liquid mole fraction.
The model is solved when the mole fractions on each stage is balanced.
Disclaimer: This calculation is a simplified model of a distillation column for preliminary design. We cannot be held responsible
for its use. As with all areas of process engineering, calculations should be checked by a competent engineer.