Академический Документы
Профессиональный Документы
Культура Документы
programming capability
E Increase safety performance levels with
application requirements
G DeviceLogix embedded control technology
e-Tools
Enclosure Rating
Frames 2-7
Frames 2-7
Frames 2-7
Frames 2-7
Frames 8-9
DriveExplorer Software
Temperature Range
0-40 C (32-104 F)
Drive
The Powerflex 750-Series drives are available with a variety of enclosure options including
IP54 (left) and an extra protection flange mount (right).
Safety
EtherNet/IPA Single Network for Complete Machine Control
Connect Your
Entire Enterprise
Benefit from the EtherNet/IP
network for complete machine
control that simplifies and
enhances machine design.
Low cost, high performance
and easy to use as compared to
a multi-network architecture
120 VAC
Input
3
1734
OW4
1
2
NODE:
24VDC
Sink
Input
220 VAC
Input
3
1734
IA4
Network
Status
Network
Status
NODE:
5
6
Module
Status
Module
Status
Module
Status
Network
Status
NODE:
Relay
Output
6500
3
1734
IM4
6500
6500
6500
6500
6500
7
1734
IB8
DANGER
EtherNet/IP is an established,
broadly-adopted network
7
4
1
8
5
2
9
6
3
755
Digital Inputs
Digital Output
Datalink Inputs
Datalink Output
Sensor
Diverter
Upstream Conveyor
Downstream Conveyor
FAULT ZONE
If door is opened during
normal operation, drive will
fault and conduct a safe stop
Monitor Delay
Set by operator determined
by application requirements
SAFE SPEED
LIMIT
DOOR
MONITORING
ACTUAL SPEED
Module
Status
Network
Status
NODE:
Operator Initiated
TIME
Safe
Limited
Speed Request
DOOR
MONITORING
Operator Initiated
Door
Released
PowerFlex 753
400/480V 0.75250 kW/1350 Hp
600/690V Logix Integration Add-on Profiles
PowerFlex 755
Embedded instructions in
RSLogix 5000
Automatic Device
Configuration
(RSLogix 5000 V20)
Add-on Profiles
Safety Options:
Safe Torque-Off, Safe
Speed Monitor
Predictive Diagnostics
Option Slots
Induction Motors
Permanent Magnet Motors
(Surface and Interior)
Positioning Indexing
Feedback Incremental
3
4
5
6
7
Indexing
PCaming
Electronic Gearing
Position/Speed Profiling
Incremental
EnDat, Hiperface, SSI and BiSS
Lifting
Torqprove
Oil Well
Pump Jack & Pump Off
Fibers
PJump & Traverse
Conformal Coating
Amps
2.1
3.5
5
8.7
11.5
15.4
22
30
37
43
60
72
85
104
140
170
205
260
302
367
456
0.75...900 kW/1...1350 Hp
250...1100Hp / 200...1000kW
DeviceLogix Control
Technology
Frame
Frame/Rating Cross-Reference
Heavy Duty kW
0.75
1.5
2.2
4
5.5
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
Amps
2.1
3.4
5
8
11
14
22
27
34
40
52
65
77
96
125
156
186
248
302
361
415
Heavy Duty HP
1
2
3
5
7.5
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
Cont.
540
585
612
750
796
832
1040
1090
1175
1465
1480
1600
Light Duty
Output Amps
1 Min.
3 Sec.
594
644
673
825
876
915
1144
1199
1293
1612
1628
1760
Cont.
485
545
590
710
765
800
960
1045
1135
1365
1420
1540
1 Min.
534
600
649
781
842
880
1056
1150
1249
1502
1562
1694
3 Sec.
Cont.
355
395
435
460
510
545
630
760
835
900
980
1045
1 Min.
391
435
479
506
561
600
693
836
919
990
1078
1150
3 Sec.
Cont.
330
370
410
460
500
530
650
710
790
860
960
1020
1 Min.
363
407
451
506
550
583
715
781
869
946
1056
1122
3 Sec.
Heavy Duty
Output Amps
1 Min.
3 Sec.
578
693
684
821
708
851
810
975
878
1125
963
1155
1125
1365
1320
1584
1365
1638
1560
1962
1635
2198
1763
2220
kW / Hp
kW
250
315
315
355
400
400
500
560
630
710
800
850
Cont.
385
456
472
540
585
642
750
880
910
1040
1090
1175
kW / Hp
kW
200
250
250
315
315
355
400
500
500
560
630
710
Hp
350
400
450
500
600
650
700
800
900
1000
1100
1250
Cont.
370
414
454
485
545
617
710
795
800
960
1045
1135
1 Min.
555
621
681
728
818
926
1065
1193
1200
1440
1568
1703
3 Sec.
666
745
818
926
1065
1110
1278
1440
1568
1728
2043
2130
Hp
300
350
350
400
450
500
600
700
750
800
900
1000
Hp
300
350
400
450
500
500
600
700
800
900
950
1000
Cont.
272
295
329
355
395
425
510
595
630
700
760
815
1 Min.
408
443
494
533
593
638
765
893
945
1050
1140
1223
3 Sec.
490
533
593
639
711
765
918
1071
1140
1260
1368
1470
Hp
250
300
350
350
400
450
500
600
700
750
800
900
kW
250
315
355
400
450
500
560
630
710
750
800
900
Cont.
215
265
308
370
375
413
460
500
590
650
750
795
1 Min.
323
398
462
555
563
620
690
750
885
975
1125
1193
3 Sec.
375
473
555
639
675
750
885
975
1065
1170
1350
1440
kW
200
250
300
355
375
400
450
500
560
630
710
800
Input Specifications
3-Phase Voltage:
Frequency:
Logic Control Ride Through:
Dimensions
Approximate Dimensions Millimeters (Inches)
Frame
Height
Width
Depth
424.20 (16.7)
134.50 (5.30)
212.00 (8.35)
454.00 (17.87)
190.00 (7.48)
212.00 (8.35)
474.00 (18.66)
222.00 (8.74)
212.00 (8.35)
550.00 (21.65)
270.00 (10.63)
212.00 (8.35)
665.50 (26.20)
308.00 (12.13)
346.40 (13.64)
881.50 (34.70)
430.00 (16.93)
350.00 (13.78)
2453.0 (88.36)
600 (23.62)
600 (23.62)*
2453.0 (96.60)
600 (23.62)
800 (31.49)*
2453.0 (96.60)
1200.0 (47.20)
600.0 (23.6)*
2453.0 (96.60)
1200.0 (47.20)
800.0 (31.50)*
Output Specifications
Voltage:
Frequency Range:
Motion Analyzer
Allen-Bradley, ControlLogix, CompactLogix, DeviceLogix, DriveExecutive, DriveExplorer, DriveObserver, DriveTools, Kinetix, PowerFlex and RSLogix, are trademarks of Rockwell Automation, Inc. Trademarks
not belonging to Rockwell Automation are property of their respective companies. ControlNet, DeviecNet and EtherNet/IP are trademarks of the Open DeviceNet Vendor Association.
Copyright 2011 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.