Hand-Held Devices II

Software Configuration Manual

Datalogic Scanning, Inc.


959 Terry Street
Eugene, Oregon 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this
documentation or the procedures described therein may be reproduced or
transmitted in any form or by any means without prior written permission of
Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or Datalogic Scanning). Owners of Datalogic products are hereby granted a nonexclusive, revocable license to reproduce and transmit this documentation
for the purchaser's own internal business purposes. Purchaser shall not
remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any
reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed
versions by contacting your Datalogic representative. Electronic versions may
either be downloadable from the Datalogic website (www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and
would like to make comments or suggestions about this or other Datalogic
publications, please let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to
change any specification at any time without prior notice.
Datalogic is a registered trademark of Datalogic S.p.A. in many countries and
the Datalogic logo is a trademark of Datalogic S.p.A. All other brand and
product names referred to herein may be trademarks of their respective owners.

CONTENTS
1

INTRODUCTION .......................................................................................... 1

INITIAL SETUP ............................................................................................ 3

CONFIGURATION...................................................................................... 12
USB PARAMETERS .................................................................................. 13
Handshaking ............................................................................................... 14
Ack/Nack Protocol....................................................................................... 14
Fifo.............................................................................................................. 15
Inter-character Delay .................................................................................. 15
Rx Timeout.................................................................................................. 16
Serial Trigger Lock...................................................................................... 16
Keyboard Nationality................................................................................... 17
Fifo.............................................................................................................. 18
Inter-character Delay .................................................................................. 18
Inter-code Delay.......................................................................................... 18
Control Character Emulation....................................................................... 19
RS232 PARAMETERS ............................................................................... 20
Baud Rate ................................................................................................... 21
Parity........................................................................................................... 22
Data Bits ..................................................................................................... 22
Stop Bits...................................................................................................... 23
Handshaking ............................................................................................... 23
Ack/Nack Protocol....................................................................................... 24
Fifo.............................................................................................................. 24
Inter-character Delay .................................................................................. 25
Rx Timeout.................................................................................................. 25
Serial Trigger Lock...................................................................................... 26
WEDGE PARAMETERS ............................................................................ 27
Keyboard Nationality................................................................................... 28
Caps Lock ................................................................................................... 29
Caps Lock Auto-Recognition (IBM AT compatible only) .............................. 29
Num Lock.................................................................................................... 30
Inter-character Delay .................................................................................. 30
Inter-code Delay.......................................................................................... 31
Control Character Emulation....................................................................... 31
Keyboard Setting ........................................................................................ 32
PEN EMULATION ...................................................................................... 34
Operating Mode .......................................................................................... 35

iii

Minimum Output Pulse................................................................................ 36


Conversion to Code 39 ............................................................................... 37
Overflow...................................................................................................... 37
Output Level................................................................................................ 38
Idle Level..................................................................................................... 38
Inter-Block Delay......................................................................................... 39
IBM 46xx .................................................................................................... 40
IBM Data Formatting................................................................................... 41
DATA FORMAT.......................................................................................... 42
Code Identifier............................................................................................. 45
Custom Code Identifier ............................................................................... 46
Header ........................................................................................................ 47
Terminator................................................................................................... 48
Field Adjustment ......................................................................................... 49
Field Adjustment Character......................................................................... 50
Code Length Tx .......................................................................................... 50
Character Replacement .............................................................................. 51
POWER SAVE............................................................................................ 53
Scan Rate ................................................................................................... 54
Sleep State/USB Suspend .......................................................................... 54
Enter Sleep Timeout ................................................................................... 55
Standby....................................................................................................... 55
READING PARAMETERS ......................................................................... 56
Hand-Held Operation .................................................................................. 57
Stand Operation.......................................................................................... 57
Hardware Trigger Signal ............................................................................. 58
Trigger-off Timeout ..................................................................................... 58
Flash Mode ................................................................................................. 59
Reads per Cycle ......................................................................................... 59
Safety Time................................................................................................. 60
Beeper Intensity .......................................................................................... 60
Beeper Tone ............................................................................................... 61
Beeper Type ............................................................................................... 61
Beeper Length ............................................................................................ 61
Good Read Spot Duration........................................................................... 62
Stand Recognition Beep ............................................................................. 62
Automatic Operation Aiming Light............................................................... 63
Aiming System ............................................................................................ 63
DECODING PARAMETERS....................................................................... 64
Ink Spread................................................................................................... 65
Overflow Control ......................................................................................... 65
Interdigit Control.......................................................................................... 66

iv

Decoding Safety.......................................................................................... 66
Puzzle Solver .......................................................................................... 67
CODE SELECTION .................................................................................... 68
EAN/UPC Family ........................................................................................ 70
2/5 Family ................................................................................................... 74
Code 39 Family........................................................................................... 75
Code 128 Family......................................................................................... 77
Code 93 ...................................................................................................... 78
Codabar Family........................................................................................... 79
MSI ............................................................................................................. 81
Plessey ....................................................................................................... 82
Telepen ....................................................................................................... 83
Delta IBM .................................................................................................... 84
Code 11 ...................................................................................................... 85
Code 16K .................................................................................................... 86
Code 49 ...................................................................................................... 86
RSS Codes ................................................................................................. 87
ADVANCED FORMATTING....................................................................... 88
Concatenation............................................................................................. 89
Advanced Formatting.................................................................................. 92
4

REFERENCES ......................................................................................... 107


A
HOST CONFIGURATION STRINGS .......................................... 123
B
CODE IDENTIFIER TABLE......................................................... 135
C
HEX/NUMERIC TABLE............................................................... 135

CONFIGURATION METHODS
Reading Configuration Barcodes
If you wish to change the default settings, this manual provides complete
configuration of your reader in an easy way:
To configure your reader:

1) Open the folded page in Appendix C with the hex-numeric table and keep it
open during the device configuration.

2) Read the Enter Configuration code ONCE, available at the top of each page
of configuration.

3) Modify the desired parameters in one or more sections following the


procedures given for each group.

4) Read the Exit and Save Configuration code ONCE, available at the top of
each page of configuration.
Reference notes describing the operation of the more complex parameters are given
in chapter 4.

Using DL Sm@rtSet
DL Sm@rtSet is a Windows-based utility program providing a quick and user-friendly
configuration method via the RS232 or USB-COM interfaces.
It also allows upgrading the software of the connected device (see the DL Sm@rtSet
Users Manual for more details).

Copy Command
A previously configured reader (Master device), can be used to send its configuration
directly to other readers of the same type. The particular procedure for each device is
given in par. 4.9.

Sending Configuration Strings from Host


An alternative configuration method is provided in Appendix A using the RS232 or
USB interfaces. This method is particularly useful when many devices need to be
configured with the same settings. Batch files containing the desired parameter
settings can be prepared to configure devices quickly and easily.

vi

INTRODUCTION

INTRODUCTION

This manual provides all the necessary information for complete software
configuration of various Datalogic families of second generation Hand-Held Devices
(HHD II), including CCD guns and readers and laser scanners.
Your reader contains a built-in decoder and multi-standard interface.
It is designed for use in a wide variety of applications and environments including
commercial, office automation, retail, and light industrial applications where
large quantities of information need to be collected rapidly, easily and reliably.
It has several status indicator functions which are described in the next paragraph.

HHD II

1.1

STATUS INDICATORS

Several status indicators are available depending on the type of reader: LEDs,
Beeper, and Good Read Spot (for CCD Long Range readers only). They signal
several operating conditions which are described in the tables below.
H = high tone

L = low tone

READER START-UP
Beeper

Meaning

LLLL

Parameters loaded correctly

H H H H
long tones
HLHL

Parameter loading error, reading or writing error in the non volatile


memory
Hardware error in EEPROM

OFF

No beeper performed when illuminator line is kept high at power on.


READER CONFIGURATION

Beeper

Meaning

HHHH

correct entry in Configuration mode

good read of a command

LLL

command read error

LHHHH

exit from Configuration mode


READER DATA ENTRY

Beeper

LED
2

one beep

Good Read Spot Meaning

ON

ON

correct read of a code in normal mode

OFF

OFF

ready to read a code

only the Beeper Intensity command can modify these signals.

the data entry good read tone is user-configurable with all the Beeper commands in the
Reading Parameters section.

INITIAL SETUP

INITIAL SETUP

2.1

INTERFACE SELECTION

Follow the procedure to configure the interface required by your application

USB Interface
RS232 Interface
Wedge Interface
Pen Emulation Interface
IBM 46xx Interface

2.1.1

USB Interface Configuration

The USB interface is compatible with:


-

Windows 98 (and later)


Mac OS 8.0 (and later)
IBM POS for Windows
4690 Operating System

The USB interface is compatible with:


Windows 98 (and later)
Mac OS 8.0 (and later)

IBM POS for Windows


4690 Operating System

START-UP
As with all USB devices, upon connection, the Host performs several checks by
communicating with the USB device. During this phase the LED on the device blinks
and normal operations are suspended. Two basic conditions must be met before the
USB device is ready to read codes, the correct USB driver must be loaded and
sufficient power must be supplied to the reader.
For all systems, the correct USB driver for the default USB-KBD interface is included
in the Host Operating System and will either be loaded automatically or will be
suggested by the O.S. and should therefore be selected from the dialog box (the first
time only).
If the Host supplies sufficient power to the reader, the start-up phase ends correctly,
the LED stops blinking and the reader emits the beep OK signal.

HHD II

If the Host does not supply sufficient power to the reader, a dialog box will appear on
the Host and the reader will be blocked (LED continues blinking). In this case,
disconnect the USB device cable at the Host (LED stops blinking), connect and
power-up an external supply to the USB device cable then reconnect the USB device
cable to the Host and close the dialog box. The reader emits the beep OK signal.
You can now read codes. At this point you can read the USB interface configuration
code according to your application. Load drivers from the O.S. (if requested). When
configuring the USB-COM interface, the relevant files and drivers must be installed
from the USB Device Installation software which can be downloaded from the web
site: http://www.scanning.datalogic.com.
The reader is ready.

First Start-Up
Connect device to
Host with USB cable

LED blinks

Load drivers
(if requested)

LED off

Disconnect reader
at Host

Connect external
power supply to
cable and power up

BEEP OK

Reconnect reader
cable to Host and
close dialog box

YES

Does a dialog
box appear
asking whether
Bus power is
sufficient?
NO
LED off - BEEP OK
Select desired
USB interface
code

Load drivers
(if requested)

Read test codes.


Reader is READY

INITIAL SETUP

Successive start-ups will automatically recognize the previously loaded drivers. If


external power is used, verify that external power is already supplied.

Successive Start-Ups
Connect device to
Host with USB cable

Disconnect reader
at Host

Connect external
power supply to
cable and power up

YES

LED blinks

Does a dialog
box appear
asking whether
Bus power is
sufficient?
NO
LED off - BEEP OK

BEEP OK

Reconnect reader
cable to Host and
close dialog box

Read test codes.


Reader is READY

HHD II
USB INTERFACE
USB-KBD

$+UA03$-:

USB-KBD-ALT-MODE

$+UA04$-@

USB-KBD-APPLE

$+UA05$-F

USB-COM*

$+UA02$-4

USB-IBM-Table Top

$+UA00$-(

USB-IBM-Hand Held

$+UA01$-.
*

When configuring USB-COM, the relevant files and drivers must be installed from
the USB Device Installation software which can be downloaded from the web site:
(see http://www.scanning.datalogic.com).

INITIAL SETUP

2.1.2

RS232 Interface Selection

Read the restore default code, then read the interface selection code for your
application:
RESTORE DEFAULT

$+$*o

RS232 INTERFACE
Standard

$+CP0$-$

POS SYSTEMS
Nixdorf Mode A

$+CM2EC0$->
Fujitsu

$+CM1$-

ICL Mode

$+CM0$-
For POS system default settings refer to par. 4.10.

HHD II

2.1.3

Wedge Interface Selection

Read the restore default code, then read the interface selection code for your
application:
RESTORE DEFAULT

$+$*o

WEDGE INTERFACE
IBM AT or PS/2 PCs

$+CP500$-a

IBM XT

$+CP503$-v

PC Notebook

$+CP505$-

IBM SURE1

$+CP506$-$

IBM Terminal 3153

$+CP504$-}

INITIAL SETUP
WEDGE INTERFACE (CONTINUED)

IBM Terminals 31xx, 32xx, 34xx, 37xx:


To select the interface for these IBM Terminals, read the correct KEY
TRANSMISSION code. select the KEYBOARD TYPE if necessary (default =
advanced keyboard).
KEY TRANSMISSION MODE
make-only keyboard

$+CP502$-o
make-break keyboard

$+CP501$-h
KEYBOARD TYPE
advanced keyboard

$+FK1$-
typewriter keyboard

$+FK0$-
ALT MODE

The following interface selection allows barcodes sent to the PC to be interpreted


correctly independently from the Keyboard Nationality used. You do not need to
make a Keyboard Nationality selection.
(default = Num Lock Unchanged). Make sure the Num Lock key on your
keyboard is ON.
IBM AT - ALT mode

$+CP507$-+
PC Notebook - ALT mode

$+CP508$-2
9

HHD II
WEDGE INTERFACE (CONTINUED)
WYSE TERMINALS
ANSI Keyboard

$+CP509$-9
PC Keyboard

$+CP510$-g
ASCII Keyboard

$+CP511$-n
VT220 style Keyboard

$+CP514$-

DIGITAL TERMINALS
VT2xx/VT3xx/VT4xx

$+CP512$-u

APPLE
APPLE ADB Bus

$+CP513$-|

10

INITIAL SETUP

2.1.4

Pen Emulation Interface Selection

Read the restore default code, then read the Pen Emulation interface selection code.
RESTORE DEFAULT

$+$*o
PEN EMULATION

$+CP6$-B
2.1.5

IBM 46xx Interface Selection


(IBM Devices only)
PORT 9B
4501 Protocol

$+CP800$-p
(typical)

1520 Protocol

$+CP801$-w

PORT 5B
1520 Protocol

$+CP801$-w
(typical)

4501 Protocol

$+CP800$-p
11

HHD II

CONFIGURATION

Once your reader is setup, you can change the default parameters to meet your
application needs. Refer to chapter 2 for initial configuration in order to set the default
values and select the interface for your application.
In this manual, the configuration parameters are divided into logical groups making it
easy to find the desired function based on its reference group.
The first four groups are for Standard Interface parameter configuration, the fifth is
only for IBM 46xx models:

USB

RS232

WEDGE

PEN EMULATION

IBM 46xx

The following parameter groups are common to all interface applications:


DATA FORMAT parameters regard the messages sent to the Host system for all
interfaces except Pen Emulation.
POWER SAVE manages overall current consumption in the reading device.
READING PARAMETERS control various operating modes and indicator status
functioning.
DECODING PARAMETERS maintain correct barcode decoding in certain special
reading conditions.
CODE SELECTION parameters allow configuration of a personalized mix of codes,
code families and their options.
ADVANCED FORMATTING PARAMETERS allow code concatenation and
advanced formatting of messages towards the Host. It cannot be used with Pen
Emulation.

12

USB PARAMETERS

USB-COM

Handshaking, Ack/Nack protocol, FIFO,


Inter-character delay, Rx timeout, Serial
trigger lock

USB-KBD

Keyboard nationality, FIFO, Inter-character


delay, Inter-code delay, Control character
emulation

USB-IBM

No parameter selection required.

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

= Read the code and follow the procedure given


= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

13

Enter Configuration

$+;

Exit and Save Configuration

USB-COM
HANDSHAKING

disable

CE0W
hardware (RTS/CTS)

CE1Z
software (XON/XOFF)

CE2]
RTS always ON

CE3`
See par. 4.1.1 for details.

ACK/NACK PROTOCOL

disable

ER0s
enable

ER1v
See par. 4.1.2 for details.

14

$-?

Enter Configuration

$+;

Exit and Save Configuration

USB-COM

$-?

FIFO

disable

EC0U

enable

EC1X
See par. 4.1.3 for details.

INTER-CHARACTER DELAY

delay between characters transmitted to Host

CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled

15

Enter Configuration

$+;

Exit and Save Configuration

USB-COM

$-?

RX TIMEOUT

timeout control in reception from Host

CL5
Read 2 numbers from the table where:
00 = TIMEOUT disabled
01-99 = TIMEOUT from .1 to 9.9 seconds
rx timeout 5 seconds

See par. 4.1.4 for details.

SERIAL TRIGGER LOCK

disabled

CR0q

enable and select characters

CR1t

Read 2 characters from the Hex/Numeric table in the range 00-FE where:

16

First Character enables device trigger


Second Character inhibits device trigger until the first character is received again.

Enter Configuration

$+;

Exit and Save Configuration

USB-KBD

$-?

KEYBOARD NATIONALITY
Not Available for USB-KBD-ALT-MODE Interface
This parameter default value is restored through the Interface Selection code and not Restore
Default.
Belgian

FJ7y
English

FJ4p
French

FJ2j
German

FJ3m
Italian

FJ1g
Japanese

FJ8|
Spanish

FJ6v
Swedish

FJ5s
USA

FJ0d

17

Enter Configuration

$+;

Exit and Save Configuration

USB-KBD
FIFO
disable

EC0U
enable

EC1X
See par. 4.1.3 for details.

INTER-CHARACTER DELAY

delay between characters transmitted to Host

CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled

INTER-CODE DELAY

delay between codes transmitted to Host

FG.
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 seconds
delay disabled

18

$-?

Enter Configuration

$+;

Exit and Save Configuration

USB-KBD

$-?

CONTROL CHARACTER EMULATION

CTRL+ Shift + Key

FO0n

CTRL + Key

FO1q

19

RS232 PARAMETERS

BAUD RATE

PARITY

DATA BITS

STOP BITS

HANDSHAKING

ACK/NACK PROTOCOL

FIFO

INTER-CHARACTER DELAY

RX TIMEOUT

SERIAL TRIGGER LOCK

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

20

= Read the code and follow the procedure given


= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

Enter Configuration

$+;

Exit and Save Configuration

RS232

$-?

BAUD RATE
300 baud

CD1X
600 baud

CD2[
1200 baud

CD3^
2400 baud

CD4a
4800 baud

CD5d
9600 baud

CD6g
19200 baud

CD7j
38400 baud

CD8m

21

Enter Configuration

$+;

Exit and Save Configuration

RS232
PARITY
none

CC0S

even parity

CC1V

odd parity

CC2Y
DATA BITS
7 bits

CA0O

8 bits

CA1R

9 bits

CA2U

22

$-?

Enter Configuration

$+;

Exit and Save Configuration

RS232

$-?

STOP BITS
1 stop bit

CB0Q

2 stop bits

CB1T
HANDSHAKING
disable

CE0W

hardware (RTS/CTS)

CE1Z

software (XON/XOFF)

CE2]

RTS always ON

CE3`
See par. 4.1.1 for details.

23

Enter Configuration

$+;

Exit and Save Configuration

RS232
ACK/NACK PROTOCOL

disable

ER0s

enable

ER1v
See par. 4.1.2 for details.

FIFO

disable

EC0U

enable

EC1X
See par. 4.1.3 for details.

24

$-?

Enter Configuration

$+;

Exit and Save Configuration

RS232

$-?

INTER-CHARACTER DELAY

delay between characters transmitted to Host

CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled

RX TIMEOUT

timeout control in reception from Host

CL5
Read 2 numbers from the table where:
00 = TIMEOUT disabled
01-99 = TIMEOUT from .1 to 9.9 seconds
rx timeout 5 seconds

See par. 4.1.4 for details.

25

Enter Configuration

$+;

Exit and Save Configuration

RS232

$-?

SERIAL TRIGGER LOCK

disabled

CR0q

enable and select characters

CR1t

Read 2 characters from the Hex/Numeric table in the range 00-FE where:

26

First Character enables device trigger


Second Character inhibits device trigger until the first character is received again.

WEDGE PARAMETERS

KEYBOARD NATIONALITY

CAPS LOCK

CAPS LOCK
AUTO-RECOGNITION

NUM LOCK

INTER-CHARACTER DELAY

INTER-CODE DELAY

CONTROL CHARACTER
EMULATION

KEYBOARD SETTING

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

= Read the code and follow the procedure given


= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

27

Enter Configuration

$+;

Exit and Save Configuration

WEDGE

$-?

KEYBOARD NATIONALITY
This parameter default value is restored through the Interface Selection code and not Restore
Default.
Belgian

FJ7y
English

FJ4p
French

FJ2j
German

FJ3m
Italian

FJ1g
Spanish

FJ6v
Swedish

FJ5s
USA

FJ0d
The Japanese Keyboard Nationality selection is valid only for IBM AT compatible PCs.
Japanese

FJ8|

28

Enter Configuration

$+;

Exit and Save Configuration

WEDGE

$-?

CAPS LOCK

caps lock OFF

FE0Z
caps lock ON

FE1]
Select the appropriate code to match your keyboard caps lock status.
Note: Caps lock manual configuration is ignored when Caps Lock Auto-Recognition is
enabled.
For PC Notebook interface selections, the caps lock status is automatically recognized,
therefore this command is not necessary.

CAPS LOCK AUTO-RECOGNITION (IBM AT COMPATIBLE ONLY)

disable

FP0p
enable

FP1s

29

Enter Configuration

$+;

Exit and Save Configuration

WEDGE

$-?

NUM LOCK

toggle num lock

FL1k

num lock unchanged

FL0h
This selection is used together with the Alt Mode interface selection for AT or Notebook PCs.
It changes the way the Alt Mode procedure is executed, therefore it should be set as follows:

if your keyboard Num Lock is normally on use num lock unchanged

if your keyboard Num Lock is normally off use toggle num lock

In this way the device will execute the Alt Mode procedure correctly for your application.

INTER-CHARACTER DELAY

delay between characters transmitted to Host

CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled

30

Enter Configuration

$+;

Exit and Save Configuration

WEDGE

$-?

INTER-CODE DELAY

delay between codes transmitted to Host

FG.
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 seconds
delay disabled

CONTROL CHARACTER EMULATION

CTRL+ Shift + Key

FO0n

CTRL + Key

FO1q

31

Enter Configuration

Exit and Save Configuration

$+;

WEDGE

$-?

KEYBOARD SETTING
ALPHANUMERIC KEYBOARD SETTING
The reader can be used with terminals or PCs with various keyboard types and nationalities
through a simple keyboard setting procedure.
The type of computer or terminal must be selected before activating the keyboard setting
command.
Keyboard setting consists of communicating to the reader how to send data corresponding to
the keyboard used in the application. The keys must be set in a specific order.
Press and release a key to set it.
Some characters may require more than one key pressed simultaneously during normal use
(refer to the manual of your PC or terminal for keyboard use). The exact sequence must be
indicated to the reader in this case pressing and releasing the different keys.
Example:
If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the
character "$" to the video, to set the "$", press and release "Shift" then press and release "4".
Each pressed and released key must generate an acoustic signal on the reader, otherwise
repress the key. Never press more than one key at the same time, even if this corresponds to
the normal use of your keyboard.
Press "Backspace" to correct a wrong key entry. In this case the reader emits 2 beeps.
Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting
procedure. "SHIFT" must be repressed for each character and cannot be substituted by
"CAPS LOCK".

setting the alphanumeric keyboard

FB0T

Read the code above.


Press the keys shown in the following table according to their numerical order:

32

Enter Configuration

Exit and Save Configuration

$+;

WEDGE

$-?

Some ASCII characters may be missing as this depends on the type of keyboard: these are
generally particular characters relative to the various national symbologies. In this case:

The first 4 characters (Shift, Alt, Ctrl, and Backspace) can only be substituted with
keys not used, or substituted with each other.

characters can be substituted with other single symbols (e.g. "SPACE") even if not
included in the barcode set used.

characters can be substituted with others corresponding to your keyboard.

The reader signals the end of the procedure with 2 beeps indicating the keys have been
registered.
01 : Shift
02 : Alt
03 : Ctrl
04 : Backspace
05 : SPACE
06 : !
07 : "
08 : #
09 : $
10 : %
11 : &
12 : '
13 : (
14 : )
15 : *
16 : +
17 : ,
18 : 19 : .
20 : /
21 : 0
22 : 1
23 : 2
24 : 3
25 : 4
26 : 5
27 : 6

28 : 7
29 : 8
30 : 9
31 : :
32 : ;
33 : <
34 : =
35 : >
36 : ?
37 : @
38 : A
39 : B
40 : C
41 : D
42 : E
43 : F
44 : G
45 : H
46 : I
47 : J
48 : K
49 : L
50 : M

51 : N
52 : O
53 : P
54 : Q
55 : R
56 : S
57 : T
58 : U
59 : V
60 : W
61 : X
62 : Y
63 : Z
64 : [
65 : \
66 : ]
67 : ^
68 : _ (underscore)
69 : `
70 : {
71 : |
72 : }
73 : ~
74 : DEL

33

PEN EMULATION

OPERATING MODE

MINIMUM OUTPUT PULSE

CONVERSION TO CODE 39

OVERFLOW

OUTPUT LEVEL

IDLE LEVEL

INTER-BLOCK DELAY

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

34

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

PEN EMULATION
The operating mode parameters are complete commands and do not require reading the
Enter and Exit configuration codes.

OPERATING MODE

interpret mode

$]8
Interprets commands without sending them to the decoder.

transparent mode

$[4
Sends commands to the decoder without interpreting them.

35

Enter Configuration

$+;

Exit and Save Configuration

PEN EMULATION

$-?

MINIMUM OUTPUT PULSE


high resolution code
emulation

200 s

DG0\
400 s

DG1_
600 s

DG2b
800 s

DG3e

1 ms

DG4h
1.2 ms
low resolution code
emulation

See par. 4.2.1 for details.

36

DG5k

Enter Configuration

$+;

Exit and Save Configuration

PEN EMULATION

$-?

CONVERSION TO CODE 39

disable conversion to Code 39

DA0P
Transmits codes in their original format.

enable conversion to Code 39

DA1S
Converts codes read into Code 39 format.

See par. 4.2.2 for details.

OVERFLOW

narrow

DH0^
medium

DH1a
wide

DH2d
See par. 4.2.3 for details.

37

Enter Configuration

$+;

Exit and Save Configuration

PEN EMULATION
OUTPUT LEVEL

normal
(white = logic level 0)

DD0V

inverted
(white = logic level 1)

DD1Y
See par. 4.2.4 for details.

IDLE LEVEL

normal
(black level)

DE0X

inverted
(white level)

DE1[
See par. 4.2.4 for details.

38

$-?

Enter Configuration

$+;

Exit and Save Configuration

PEN EMULATION

$-?

INTER-BLOCK DELAY

delay between character blocks transmitted to Host

CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from .1 to 9.9 seconds
delay disabled

See par. 4.2.5 for details.

39

IBM 46XX

IBM DATA FORMATTING

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

40

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

Enter Configuration

$+;

Exit and Save Configuration

IBM 46xx

$-?

IBM DATA FORMATTING

conversion to Code 39

GD0Y
IBM Standard

GD1\
mixed IBM Standard + Code 39

GD2_
See par. 4.3.1 for details.

41

DATA FORMAT
NOT FOR PEN INTERFACES

CODE IDENTIFIER

CUSTOM CODE IDENTIFIER

HEADER

TERMINATOR

FIELD ADJUSTMENT

FIELD ADJ. CHARACTER

CODE LENGTH TX

CHARACTER REPLACEMENT

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

42

= Read the code and follow the procedure given


= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

DATA FORMAT

CODE IDENTIFIER TABLE


CODE
2/5 interleaved
2/5 industrial
2/5 normal 5 bars
2/5 matrix 3 bars
EAN 8
EAN 13
UPC A
UPC E
EAN 8 with 2 ADD ON
EAN 8 with 5 ADD ON
EAN 13 with 2 ADD ON
EAN 13 with 5 ADD ON
UPC A with 2 ADD ON
UPC A with 5 ADD ON
UPC E with 2 ADD ON
UPC E with 5 ADD ON
Code 39
Code 39 Full ASCII
CODABAR
ABC CODABAR
Code 128
EAN 128

ISBT 128
Code 93
CIP/39
CIP/HR
Code 32
MSI
Plessey Standard
Plessey Anker
Telepen
Delta IBM
Code 11
Code 16K
Code 49
RSS Expanded Linear and Stacked
RSS Limited
RSS 14 Linear and Stacked

AIM STANDARD

DATALOGIC STANDARD

]Iy
]Xy
]Sy
]Xy
]E4
]E0
]Xy
]Xy
]E5
]E6
]E1
]E2
]Xy
]Xy
]Xy
]Xy
]Ay
]Ay
]Fy
]Xy
]Cy
]Cy
] C4
]Gy
]Xy
]Xy
]Xy
]My
]P0
]P1
]X0
]X0
]Hy
]K0
]Ty
]e0
]e0
]e0

N
P
O
Q
A
B
C
D
J
K
L
M
F
G
H
I
V
W
R
S
T
k
f
U
Y
e
X
Z
a
o
d
c
b
p
q
t
v
u

Custom

43

DATA FORMAT

AIM standard identifiers are not defined for all codes: the X identifier is assigned to the
code for which the standard is not defined. The y value depends on the selected options
(check digit tested or not, check digit tx or not, etc.).

When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can
be defined for each code type. If only 1 identifier character is required, the second
character must be selected as FF (disabled).

The code identifier can be singly disabled for any code by simply selecting FF as the first
identifier character.

Write in the Custom character identifiers in the table above for your records.

44

Enter Configuration

$+;

Exit and Save Configuration

DATA FORMAT

$-?

CODE IDENTIFIER

disable

EB0S

Datalogic standard

EB1V

AIM standard

EB2Y

custom

EB3\

45

Enter Configuration

Exit and Save Configuration

$+;

$-?

DATA FORMAT
CUSTOM CODE IDENTIFIER

define custom code identifier(s)

EH/

Read the above code.


(Code Identifiers default to Datalogic standard, see table on previous page).

Select the code type from the code table in Appendix B for the identifier you want to
change.

You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is
required, the second character must be selected as FF (disabled). Read the hexadecimal
value corresponding to the character(s) you want to define as identifiers for the code
selected in step : valid characters are in the range 00-FD.

Example:

To define Code 39 Code Identifier = @

define custom code identifier(s)

Read

46

EH/

Code 39

VW

40

FF

Enter Configuration

$+;

Exit and Save Configuration

$-?

DATA FORMAT
HEADER

no header

EA00*
one character header

EA01.

two character header

EA022
three character header

EA036

four character header

EA04:
five character header

EA05>

six character header

EA06B
seven character header

EA07F

eight character header

EA08J

After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters
are in the range 00-FE.
Example:
four character header

+ 41 + 42 + 43 + 44 = Header ABCD
For more details see par. 4.4.1.

47

Enter Configuration

$+;

Exit and Save Configuration

$-?

DATA FORMAT
TERMINATOR

no terminator

EA10-
one character terminator

EA111

two character terminator

EA125
three character terminator

EA139

four character terminator

EA14=
five character terminator

EA15A

six character terminator

EA16E
seven character terminator

EA17I

eight character terminator

EA18M

After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters
are in the range 00-FE.
Example:
two character terminator

+ 0D + 0A = Terminator CR LF
For more details see par. 4.4.1.

48

Enter Configuration

Exit and Save Configuration

$+;

$-?

DATA FORMAT
FIELD ADJUSTMENT
disable field adjustment

EF0[
Field adjustment allows a number of characters n, to be added to or subtracted from the
barcode read. The adjustment can be different for each enabled code type. To define the field
adjustment:

Read the enable field adjustment code:


enable field adjustment

EF+

Select the code type from the Code Identifier Table in Appendix B.
Select the type of adjustment to perform:
right addition

01
left addition

12
right deletion

23
left deletion

34
Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many
characters to add or delete:
Conditions:

Adjustment is only performed on the barcode data, the Code Identifier and Code Length
Transmission fields are not modified by the field adjustment parameter.

If the field setting would subtract more characters than exist in the barcode, the subtraction
will take place only to code length 0.

You can set up to a maximum of 10 different field adjustments on the same barcode family
or on different barcode families.

Example: To add 4 characters to the right of Standard Code 39 Codes:


enable field adjustment

Read

EF+

Code 39

VW

right addition

01

04

49

Enter Configuration

Exit and Save Configuration

$+;

DATA FORMAT

$-?

FIELD ADJUSTMENT CHARACTER


Read the field adjustment character code:
field adjustment character

EG-

Read the hexadecimal value corresponding to the character you want to use for field
adjustment. Valid characters are in the range 00-FE.
Example:
To define the field adjustment character = A:
field adjustment character

Read

+ 41

CODE LENGTH TX
code length not transmitted

EE0Y
code length transmitted in variable-digit format

EE1\
code length transmitted in fixed 4-digit format

EE2_
The code length is transmitted in the message after the Headers and Code Identifier characters.
The code length is calculated after performing any field adjustment operations.

50

Enter Configuration

$+;

Exit and Save Configuration

DATA FORMAT

$-?

CHARACTER REPLACEMENT
disable character replacement

EO0m
This parameter allows up to three characters to be replaced from the barcode read. These
substitutions are stored in memory. To define each character replacement:

Read one of the following character replacement codes:


first character replacement

EO1p
second character replacement

EO2s
third character replacement

EO3v

From the Code Identifier Table in Appendix B, read the Code Identifier for the desired
code family.
0 = character replacement will be effective for all code families.

From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE)
which identifies the character to be replaced.

From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE)
which identifies the new character to replace.
FF = the character to be replaced will be substituted with no character, that is, it will be
removed from the code.

51

Enter Configuration

Exit and Save Configuration

$+;

$-?

DATA FORMAT

Example:
The following strings define:
1.

First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0


character with the 1 character.

2.

Second Character Replacement: substitution in Code 39 barcodes of all occurrences of


the A character with the B character.

first character replacement

Code 39

EO1p + VW +

ASCII characters corresponding to


the HEX value for character 0

30

ASCII characters corresponding


to the HEX value for character 1

31

For Code 39 codes containing the string "0123", the contents transmitted will be "1123".

second character
replacement

Code 39

EO2s + VW +

ASCII characters corresponding to


the HEX value for character A

41

ASCII characters corresponding


to the HEX value for character B

42

For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".

52

POWER SAVE

SCAN RATE

SLEEP STATE/USB SUSPEND

ENTER SLEEP TIMEOUT

STANDBY

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

= Read the code and follow the procedure given


= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

53

Enter Configuration

$+;

Exit and Save Configuration

POWER SAVE

$-?

SCAN RATE

CCD Readers ONLY


quarter

BT0t
half

BT1w
maximum

BT2z
A lower scan rate reduces power consumption but can lengthen reading response time.

SLEEP STATE/USB SUSPEND

ONLY Devices with Button/Trigger


disable

BQ0n
enable

BQ1q
See par. 4.5.1 for details.

54

Enter Configuration

$+;

Exit and Save Configuration

POWER SAVE

$-?

ENTER SLEEP TIMEOUT


ONLY Devices with Button/Trigger

enter sleep timeout

BR@
Read 2 numbers in the range 00-99:
00 = Enter Sleep state immediately
01-99 = corresponds to a max. 9.9 sec. delay before entering the
Sleep state.

See par. 4.5.2 for details.

STANDBY

ONLY for CCD Devices


disable

BM1i
optimize for reading speed

enable

BM0f
optimize for low power consumption

See par. 4.5.3 for details.

55

READING PARAMETERS

HAND-HELD OPERATION

STAND OPERATION

TRIGGER SIGNAL

TRIGGER-OFF TIMEOUT

FLASH MODE

READS PER CYCLE

SAFETY TIME

BEEPER INTENSITY

BEEPER TONE

BEEPER TYPE

BEEPER LENGTH

GOOD READ SPOT DURATION

STAND RECOGNITION BEEP

AUTOMATIC OPERATION
AIMING LIGHT

AIMING SYSTEM

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

56

= Read the code and follow the procedure given


= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

Enter Configuration

Exit and Save Configuration

$+;

$-?

READING PARAMETERS
HAND-HELD OPERATION

hardware trigger

BK1e
software trigger

BK0b
always on

BK3k
automatic

BK2h
* hardware trigger ready

BK4n
= default value for devices with trigger

= default value for devices without trigger

* = only for CCD readers with trigger

= only for CCD readers

For Automatic Hand-Held or Stand Operation, the Safety Time parameter is forced to no code
consecutive reading (00).
See par. 4.6.1 for details

STAND OPERATION
ONLY Devices with Stand Recognition Beep
hardware trigger

BU3
software trigger

BU1y
always on

BU2|
automatic

BU0v
See par. 4.6.1 for details

57

Enter Configuration

$+;

Exit and Save Configuration

READING PARAMETERS

$-?

HARDWARE TRIGGER SIGNAL

ONLY Devices with Button/Trigger


trigger active level

BA0N
trigger active pulse

BA1Q
See par. 4.6.2 for details

TRIGGER-OFF TIMEOUT
ONLY Devices with Button/Trigger

trigger-off timeout

BD$
Read 2 numbers in the range 00-99:
00 = disables the trigger-off timeout
01-99 = corresponds to a max. 99-sec. delay after the trigger
press to allow the reader to turn off automatically.
trigger-off timeout disabled

See par. 4.6.3 for details.

58

Enter Configuration

$+;

Exit and Save Configuration

READING PARAMETERS

$-?

FLASH MODE

"FLASH" ON duration

"FLASH" OFF duration

BB0P

BB1S
Read 2 numbers in the range 01-99:
01 to 99 = from .1 to 9.9 seconds.
Flash-ON = 1 sec. Flash-OFF = 0.6 sec

READS PER CYCLE

one read per cycle

BC0R
multiple reads per cycle

BC1U
See par. 4.6.4 for details.

59

Enter Configuration

$+;

Exit and Save Configuration

READING PARAMETERS

$-?

SAFETY TIME

safety time

BE&
Limits same code consecutive reading.

Read 2 numbers in the range 00-99:


00 = no same code consecutive reading until reader is
removed (no decoding) for at least 400 ms.
01-99 = timeout from .1 to 9.9 seconds before a consecutive read
on same code.
safety time = 0.5 sec

See par. 4.6.5 for details.

BEEPER INTENSITY
beeper off *

BG0Z
low intensity

BG1]
medium intensity

BG2`
high intensity

BG3c
*

60

This sets the beeper OFF for data entry, while for all other beeper signals it has the
meaning very low intensity. The Beeper Intensity parameter is effective for all operating
conditions described in par. 1.1.

Enter Configuration

$+;

Exit and Save Configuration

READING PARAMETERS

$-?

BEEPER TONE
tone 1

BH0\
tone 2

BH1_
tone 3

BH2b
tone 4

BH3e
BEEPER TYPE
monotone

BJ0`
bitonal

BJ1c
BEEPER LENGTH
long

BI0^
short

BI1a
61

Enter Configuration

$+;

Exit and Save Configuration

READING PARAMETERS

$-?

GOOD READ SPOT DURATION

CCD Long Range Readers ONLY

disable

BV0x
short

BV1{
medium

BV2~
long

BV3
STAND RECOGNITION BEEP

ONLY Readers with Stand Recognition

disable

Ba0'
enable

Ba1*

62

Enter Configuration

Exit and Save Configuration

$+;

$-?

READING PARAMETERS
AUTOMATIC OPERATION AIMING LIGHT

CCD Long Range Readers ONLY

disable

Bb0)
enable

Bb1,
See par. 4.6.6 for details.

AIMING SYSTEM

Laser Readers ONLY

disable

BX0|
300 ms

BX1
500 ms

BX2
1 sec

BX3
See par. 4.6.7 for details.

63

DECODING PARAMETERS

INK SPREAD

OVERFLOW CONTROL

INTERDIGIT CONTROL

DECODING SAFETY

PUZZLE SOLVER

Before changing these parameter values read the descriptions in


par. 4.7.
CAUTION

1.
2.
3.

64

Read the Enter Configuration code ONCE, available at the top of each page.
Read configuration codes from the desired groups.

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

Enter Configuration

$+;

Exit and Save Configuration

DECODING PARAMETERS

$-?

INK SPREAD

disable

AX0{

enable

AX1~
See par. 4.7.1 for details.

OVERFLOW CONTROL

disable

AW1|

enable

AW0y
See par. 4.7.2 for details.

65

Enter Configuration

Exit and Save Configuration

$+;

$-?

DECODING PARAMETERS
INTERDIGIT CONTROL

disable

AV0w

enable

AV1z
See par. 4.7.3 for details.

DECODING SAFETY

one read

ED0W
(decoding safety disabled)
two reads

ED1Z
three reads

ED2]
four reads

ED3`
Required number of good reads before accepting code.

66

Enter Configuration

Exit and Save Configuration

$+;

DECODING PARAMETERS

$-?

PUZZLE SOLVER

disable

AU0u

enable

AU1x
In the case of damaged or poorly printed codes, this parameter allows reading multiple parts of
the single code to reconstruct it.
To read codes using this technology, simply move the reader over the code so that each line of
the code is scanned.

Conditions:

This parameter is only valid for the following codes:


EAN 8
without Add-on

EAN 13
without Add-on

Code 128

Code 39

UPC A
without Add-on

For Code 39, Check digit control without transmission is forced.

PuzzleSolver is disabled when code ISBT 128 is enabled.

67

CODE SELECTION

EAN/UPC FAMILY
2/5 FAMILY
CODE 39 FAMILY
CODE 128 FAMILY
CODABAR FAMILY
CODE 93
MSI
PLESSEY
TELEPEN
DELTA IBM
CODE 11
CODE 16K
CODE 49
RSS CODES

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

68

= Read the code and follow the procedure given


= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
each page.

Enter Configuration

Exit and Save Configuration

$+;

CODE SELECTION

$-?

DISABLES ALL CODE FAMILIES

AZ0
The reader allows up to 5 code selections. This does not limit the
number of CODES enabled to 5, as it depends on the code family.
NOTE

SINGLE
SELECTIONS =

ONE combination code from the EAN family

ONE code from the 2/5 family

Example
5 code selections:

1. 2/5 Interleaved
2. 2/5 Industrial
3. Code 128 + EAN 128
4. Code 39 Full ASCII + Code 32
5. UPC A/UPC E

In this section all SINGLE code selections are underlined and in bold.

69

Enter Configuration

Exit and Save Configuration

$+;

CODE SELECTION

$-?

EAN/UPC FAMILY

disable the family

AA0M
Read the desired family code
Note:
Since the EAN/UPC without ADD ON code selection is enabled by default, to correctly enable
another selection, first disable the family.

EAN 8/EAN 13/UPC A/UPC E with and without ADD ON

AA8e

WITHOUT ADD ON

EAN 8/EAN 13/UPC A/UPC E

AA1P
EAN 8/EAN 13

AA3V
UPC A/UPC E

AA4Y

70

Enter Configuration

Exit and Save Configuration

$+;

$-?

CODE SELECTION
WITH ADD ON 2 AND 5

EAN 8/EAN 13/UPC A/UPC E

AA5\
EAN 8/EAN 13

AA6_
UPC A/UPC E

AA7b
WITH ADD ON 2 ONLY

EAN 8/EAN 13

AAK7
UPC A/UPC E

AAM=
WITH ADD ON 5 ONLY

EAN 8/EAN 13

AAL:
UPC A/UPC E

AAN@

71

Enter Configuration

Exit and Save Configuration

$+;

$-?

CODE SELECTION
EAN/UPC CHECK DIGIT TX SELECTIONS

For each code type in this family you can choose to transmit the check digit or not
CHECK DIGIT TRANSMISSION
NO CHECK DIGIT
TRANSMISSION
EAN 8

AAG1o
EAN 8

AAG0k
EAN 13

AAH1r
EAN 13

AAH0n
UPC A

AAI1u
UPC A

AAI0q
UPC E

AAJ1x
UPC E

AAJ0t

72

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

CONVERSION OPTIONS
UPC E to UPC A conversion

AAA
UPC E to EAN 13 conversion

AAB
UPC A to EAN 13 conversion

AAC
EAN 8 to EAN 13 conversion

AAD"
Enable only ISBN conversion

AP1n
Enable only ISSN conversion

AP2q
Enable both ISBN and ISSN conversion

AP3t
Disable both ISBN and ISSN conversion

AP0k
73

Enter Configuration

$+;

Exit and Save Configuration

$-?

CODE SELECTION
2/5 FAMILY
disables the family

AC0Q
Read the desired family code

Read a check digit selection

Interleaved 2/5

AC1T

CHECK DIGIT TABLE


no check digit control

12
Normal 2/5 (5 Bars)

AC2W
check digit control and transmission

23
Industrial 2/5 (IATA)

AC3Z
check digit control without transmission

34
Matrix 2/5 (3 Bars)

AC4]

Read 4 numbers for the code length

The pharmaceutical code below is part of


the 2/5 family but has no check digit or
code length selections.
Code CIP/HR

AC5`
French pharmaceutical code

74

where:
First 2 digits = minimum code
length.
Second 2 digits = maximum code
length.

The maximum
characters.

code length is 99

The minimum code length must always


be less than or equal to the maximum.
Examples:
0199 = variable from 1 to 99 digits in
the code.
1010 = 10 digit code length only.

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

CODE 39 FAMILY

disables the family

AB0O

Read the desired family code

Read a check digit selection


CHECK DIGIT TABLE

Standard Code 39

AB1R

Full ASCII Code 39

AB2U

no check digit control

12

check digit control


and transmission

23

check digit control


without transmission

34

75

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

The pharmaceutical codes below are part of the Code 39 family but have no check digit
selections.

Code CIP39

AB3X
French pharmaceutical code

Code 32

AB4[
Italian pharmaceutical code

CODE LENGTH (optional)


The code length selection is valid for the entire Code 39 family
Read the code + 4 numbers for the code length where:
First 2 digits = minimum code length.
Second 2 digits = maximum code length.

set code length

AB*=

The maximum code length is 99 characters.


The minimum code length must always be less than or equal to the maximum.
Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.

76

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

CODE 128 FAMILY


disables the family

AI0]
Read the desired family code
Code 128

AI11=
control without transmission
of check digit

EAN 128

AI21@
control without transmission
of check digit

Transmit GS Before Code


Code EAN 128 uses the ASCII <GS> character to separate a variable length code field from the
next code field. This character can also be transmitted before the code.
disable

EQ0q
enable

EQ1t
If the <GS> character has been modified in the Character Replacement parameter, the new
character is affected by this command.

77

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

ISBT 128

AI31C
Enabling ISBT 128 automatically disables Puzzle Solver.

CODE LENGTH (optional)


The code length selection is valid for the entire Code 128 family.
Read the code + 4 numbers for the code length where:

set code length

AILJ

First 2 digits = minimum code length


Second 2 digits = maximum code length

The maximum code length is 99 characters. The minimum code length must always be less
than or equal to the maximum.
Examples:

0199 = variable from 1 to 99 digits in the code. 1010= 10 digit code length only.

The length is calculated on the output string.

CODE 93

disables the code

AK0a
Code 93

AK1d
control without transmission
of check digit

78

Enter Configuration

Exit and Save Configuration

$+;

$-?

CODE SELECTION
CODABAR FAMILY

disables the family

AD0S
Read the desired equality control code

Read a start/stop transmission


selection
START/STOP CHARACTER
TRANSMISSION

Standard Codabar

AD113
no start/stop character equality control
no transmission

12
Standard Codabar

AD127
start/stop character equality control
transmission

23
The Codabar ABC code below uses a fixed start/stop character transmission selection.

Codabar ABC

AD212)
no start/stop character equality control but transmission.

79

Enter Configuration

Exit and Save Configuration

$+;

$-?

CODE SELECTION
Codabar ABC Forced Concatenation
enable Codabar ABC with forced concatenation

AD2321
non start/stop character equality control but transmission

CODE LENGTH (optional)


The code length selection is valid for the entire Codabar family
Read the code + 4 numbers for the code length where:
First 2 digits = minimum code length.
Second 2 digits = maximum code length.

set code length

AD*A

The maximum code length is 99 characters.


The minimum code length must always be less than or equal to the maximum.
Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.

START/STOP CHARACTER CASE IN TRANSMISSION

The start/stop character case selections below are valid for the entire Codabar family:

transmit start/stop characters in lower case

ADA0_
transmit start/stop characters in upper case

ADA1c

80

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

MSI
disables the family

AE0U
Enable the code by selecting one of the check digit selections.
no check digit control

AE1X
MOD10 check digit control
no check digit transmission

AE2[
MOD10 check digit control
check digit transmission

AE3^
MOD11 - MOD10 check digit control
no check digit transmission

AE4a
MOD11 - MOD10 check digit control
check digit transmission

AE5d
MOD10 - MOD10 check digit control
no check digit transmission

AE6g
MOD10 - MOD10 check digit control
check digit transmission

AE7j
81

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

PLESSEY
disables the family

AF0W
Enable the code by selecting one of the check digit selections.

Standard Plessey
no check digit control

AF117
check digit control
check digit transmitted

AF12;
check digit control
check digit not transmitted

AF13?
Anker Plessey
no check digit control

AF21:
check digit control
check digit transmitted

AF22>
check digit control
check digit not transmitted

AF23B
82

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

TELEPEN
disables the family

AL0c
Enable the code by selecting one of the check digit selections.

Numeric Telepen
no check digit control

AL11C
check digit control
check digit transmitted

AL12G
check digit control
check digit not transmitted

AL13K
Alphanumeric Telepen
no check digit control

AL21F
check digit control
check digit transmitted

AL22J
check digit control
check digit not transmitted

AL23N
83

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION
DELTA IBM
disables the family

AH0[
Enable the code by selecting one of the check digit selections.

no check digit control

AH1^

Type 1 check digit control

AH2a

Type 2 check digit control

AH3d

84

$-?

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

CODE 11
disables the family

AG0Y
Enable the code by selecting one of the check digit selections.
no check digit control

AG1\
Type C check digit control
check digit transmitted

AG21<
Type C check digit control
check digit not transmitted

AG22@
Type K check digit control
check digit transmitted

AG31?
Type K check digit control
check digit not transmitted

AG32C
Type C and Type K
check digit control
check digits transmitted

AG41B
Type C and Type K
check digit control
check digits not transmitted

AG42F

85

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

CODE 16K

disables the code

AJ0_

Code 16K

AJ1b
To read stacked codes, simply move the reader over the code so that each line of the code is
scanned.

CODE 49

disables the code

AM0e

Code 49

AM1h
To read stacked codes, simply move the reader over the code so that each line of the code is
scanned.

86

Enter Configuration

$+;

Exit and Save Configuration

CODE SELECTION

$-?

RSS CODES
disables the family

AQ0m
DISABLE CODE
ENABLE CODE
disable RSS Expanded Linear and Stacked

AQ10I
enable RSS Expanded Linear and Stacked

AQ11M
disable RSS Limited

AQ20L
enable RSS Limited

AQ21P
disable RSS 14 Linear and Stacked

AQ30O
enable RSS 14 Linear and Stacked

AQ31S
To read the stacked version of these codes, simply move the reader over the code so that each
line of the code is scanned.

87

ADVANCED FORMATTING

CONCATENATION

ADVANCED FORMATTING

Please follow the setup procedure carefully for these parameters.


NOTE

1.
2.

Read the Enter Configuration code ONCE, available at the top of page .
Read configuration codes precisely following the numbered procedure
given.

3.

88

= Read the code and follow the procedure given

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of
page.

Enter Configuration

$+;

Exit and Save Configuration

ADVANCED FORMATTING

$-?

CONCATENATION

disable

EI0a
enable

EI1d
Permits the concatenation of two codes defined by code type and length. It is possible to set a
timeout for the second code reading and to define code transmission if the timeout expires.
The order of transmission is CODE 1-CODE 2.

Define Concatenation

Code 1
code ID

EK0e
Read the code type from the Code Identifier Table beginning in Appendix B.
code length

EL0g
Read a number in the range 01-99 from the Hex/Numeric Table.

89

Exit and Save Configuration

ADVANCED FORMATTING
2

$-?

Code 2
code ID

EK1h
Read the code type from the Code Identifier Table beginning in Appendix B.
code length

EL1j
Read a number in the range 01-99 from the Hex/Numeric Table.

Concatenation Result Code ID


use code 1 ID

EN0k
use code 2 ID

EN1n
Since you can concatenate codes from different families, you must select the Code ID character
of the resulting code. The Code ID character will be sent in the output message only if it is
enabled according to the Code Identifier selection (Datalogic, AIM, or Custom).

Concatenation Timeout
timeout

EJ3
Read two numbers in the range 00 to 99
00= no timeout
01-99 = timeout from 1 to 99 seconds

Define the timeout, which determines the valid waiting period between the two codes, in order to
accept concatenation. If the timeout expires, the resulting action will be based on the following
selection.

90

Exit and Save Configuration

ADVANCED FORMATTING
5

$-?

Transmission after Timeout


no code transmitted
after timeout

EM0i
only code 1 transmitted
(if read) after timeout

EM1l
only code 2 transmitted
(if read) after timeout

EM2o
either code 1 or code 2 transmitted
after timeout

EM3r

91

ADVANCED FORMATTING
ADVANCED FORMATTING
Advanced formatting has been designed to offer you complete flexibility in changing the format
of barcode data before transmitting it to the host system. This formatting will be performed
when the barcode data meets certain criteria which you will define in the following procedure.
Up to 4 advanced code management formats can be defined and saved in memory. For each
format you must complete the entire configuration procedure:
Read the Enter
Configuration Command
Step 1
Begin Format Definition
1, 2, 3, or 4
Steps 2 - 4
Define Match Code Conditions
Step 5
Divide Code into Fields
Step 6
Define Code Fields
Steps 7 - 8
Add up to 2 Additional Fields
Step 9
Define Field Transmission
Step 10
Apply or Not
Standard Message Formatting
Step 11
End Format Definition
1, 2, 3, or 4
YES

Define another?
NO

Enable Advanced Formats


1, 2, 3, 4
Define No Match Result
Read the Exit and Save
Configuration Command

92

Enter Configuration

$+;

Exit and Save Configuration

ADVANCED FORMATTING

$-?

Begin Format Definition

begin Format 1 definition

HA0T
begin Format 2 definition

HA1W
begin Format 3 definition

HA2Z
begin Format 4 definition

HA3]

Match Code Type


match code type

HB&

Read the above code + the code type to match from the Code Identifier Table in Appendix B.
OR

any code type

HB0V
3

Match Code Length


match code length

HC(

Read the above code + two numbers in the range 01 to 99 for the exact code length.
OR

any code length

HC001
93

Exit and Save Configuration

ADVANCED FORMATTING
4

$-?

Match with Predefined Characters


no match

HD0HE00
OR

match with 1 character

HD1]
match with a 2-character string

HD2`
match with a 3-character string

HD3c
match with a 4-character string

HD4f

After selecting the predefined match code, read the character(s) from the HEX table. Range
of characters = 01-FE.
Example:
Match code with the 2-character predefined string = "@@".
Match with a 2-character string

Read

AND

+ 40 + 40

position of first character in predefined string

HE,

Read the above code + two numbers in the range 01 to 99 representing the character
position in the code where the first character of the predefined string must be found.
Read 00 if the match string can be found in any character position.

94

Exit and Save Configuration

ADVANCED FORMATTING
5

$-?

Divide Code into Fields


divide code into fields

HF.

Read one number in the range 1 to 5 to divide the code into fields.

Define Code Fields


define code fields

Each code field length can be set by either:


a) defining a field separator character to be found in the code itself. In this case you can
choose to discard the code separator character or include it as the last character of the
field.
OR BY
b) defining a match character to be found consecutively repeated in the code itself. In this
case the field ends with the first character that does not match.
OR BY
c) specifying a specific character length up to the maximum of 99 characters.
OR BY
d) selecting the last field as variable length (if any).

You must define the same number of fields as selected in step 5, including fields that will
not be transmitted.

95

Exit and Save Configuration

$-?

ADVANCED FORMATTING
DEFINE FIELD 1 BY:
EITHER
field separator

a)

HG0`

Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator

01

12
OR
match character

b)

HG3i

Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length

c)

HG1c

Read two numbers in the range 01 to 99 to define the field length.


OR
this is the last field (variable length)

d)

HG2f
AND
Field 1 Terminators
no field terminators

HH0b
1 field terminator

HH1e

2 field terminators

HH2h

Read the field terminator character(s) from the HEX table.


Valid range of characters for all readers = 01-FE.
For readers using Wedge interface, all values from 9C to FE send the Space character.

96

Exit and Save Configuration

$-?

ADVANCED FORMATTING
DEFINE FIELD 2 BY:
EITHER
field separator

a)

HG0`

Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator

01

12
OR
match character

b)

HG3i

Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length

c)

HG1c

Read two numbers in the range 01 to 99 to define the field length.


OR
this is the last field (variable length)

d)

HG2f
AND
Field 2 Terminators
no field terminators

HH0b
1 field terminator

HH1e

2 field terminators

HH2h

Read the field terminator character(s) from the HEX table.


Valid range of characters for all readers = 01-FE.
For readers using Wedge interface, all values from 9C to FE send the Space character.

97

Exit and Save Configuration

$-?

ADVANCED FORMATTING
DEFINE FIELD 3 BY:
EITHER
field separator

a)

HG0`

Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator

01

12
OR
match character

b)

HG3i

Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length

c)

HG1c

Read two numbers in the range 01 to 99 to define the field length.


OR
this is the last field (variable length)

d)

HG2f
AND
Field 3 Terminators
no field terminators

HH0b
1 field terminator

HH1e

2 field terminators

HH2h

Read the field terminator character(s) from the HEX table.


Valid range of characters for all readers = 01-FE.
For readers using Wedge interface, all values from 9C to FE send the Space character.

98

Exit and Save Configuration

$-?

ADVANCED FORMATTING
DEFINE FIELD 4 BY:
EITHER
field separator

a)

HG0`

Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator

01

12
OR
match character

b)

HG3i

Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length

c)

HG1c

Read two numbers in the range 01 to 99 to define the field length.


OR
this is the last field (variable length)

d)

HG2f
AND
Field 4 Terminators
no field terminators

HH0b
1 field terminator

HH1e

2 field terminators

HH2h

Read the field terminator character(s) from the HEX table.


Valid range of characters for all readers = 01-FE.
For readers using Wedge interface, all values from 9C to FE send the Space character.

99

Exit and Save Configuration

$-?

ADVANCED FORMATTING
DEFINE FIELD 5 BY:
EITHER
field separator

a)

HG0`

Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator

01

12
OR
match character

b)

HG3i

Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length

c)

HG1c

Read two numbers in the range 01 to 99 to define the field length.


OR
this is the last field (variable length)

d)

HG2f
AND
Field 5 Terminators
no field terminators

HH0b
1 field terminator

HH1e

2 field terminators

HH2h

Read the field terminator character(s) from the HEX table.


Valid range of characters for all readers = 01-FE.
For readers using Wedge interface, all values from 9C to FE send the Space character.

100

Exit and Save Configuration

ADVANCED FORMATTING
7

$-?

First Additional Fixed Field


no fixed field

HI0d
1 character fixed field

HI1g
2 character fixed field

HI2j
3 character fixed field

HI3m
4 character fixed field

HI4p
5 character fixed field

HI5s
6 character fixed field

HI6v

After selecting one of the Additional Fixed Field codes, read the corresponding character(s)
from the HEX table. Range of characters = 01-FE. For readers using Wedge interface, all
values from 9C to FE send the Space character.
Example:
4 Character Fixed Field

+ 4D + 41 + 49 + 4E =

MAIN

101

Exit and Save Configuration

ADVANCED FORMATTING
8

$-?

Second Additional Fixed Field


no fixed field

HJ0f
1 character fixed field

HJ1i
2 character fixed field

HJ2l
3 character fixed field

HJ3o
4 character fixed field

HJ4r
5 character fixed field

HJ5u
6 character fixed field

HJ6x

After selecting one of the Additional Fixed Field codes, read the corresponding character(s)
from the HEX table. Range of characters = 01-FE. For readers using Wedge interface, all
values from 9C to FE send the Space character.
Example:
3 Character Fixed Field

+ 53 + 45 + 54 =

102

SET

Exit and Save Configuration

ADVANCED FORMATTING
9

$-?

Field Transmission
number of fields to transmit

HK8
Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to
be transmitted.
Field Order Transmission
Read the codes corresponding to the fields to transmit in the order in which they are to be
transmitted. A field can be transmitted more than once. See example.
field 1

12
field 2

23
field 3

34
field 4

45
field 5

56
additional field 1

67
additional field 2

78
Example:
The barcode is divided into 3 defined fields plus 1 additional fixed field.
Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2.
Number of Fields
to Transmit

Field 2

+4+

Additional Field 1

Field 1

Field 2

103

Exit and Save Configuration

ADVANCED FORMATTING
10

$-?

Standard Formatting
do not apply standard formatting

HL0j

apply standard formatting

HL1m
After performing Advanced Formatting on the barcode read, Standard Formatting (Headers,
Code Length, Code ID, Terminators) can be applied to the message to be transmitted.

11

End Format Definition


end Format 1 definition

HM0l

end Format 2 definition

HM1o

end Format 3 definition

HM2r

end Format 4 definition

HM3u

104

Enter Configuration

$+;

Exit and Save Configuration

ADVANCED FORMATTING

$-?

Enable Advanced Format


no Advanced Formats enabled

HN0n
Advanced Format 1
enable

HN11N

disable

HN10J
Advanced Format 2
enable

HN21Q

disable

HN20M
Advanced Format 3
enable

HN31T

disable

HN30P
Advanced Format 4
enable

HN41W

disable

HN40S

105

Enter Configuration

$+;

Exit and Save Configuration

ADVANCED FORMATTING

$-?

No Match Result
clear data - no transmission

HO0p
transmit data using standard format

HO1s
This selection determines the action to be taken when codes read do not conform to the
advanced format requisites (no match).

106

Codes not matching can be ignored, cleared from memory and not transmitted.

Codes not matching can be transmitted using the Standard formatting (Headers,
Code Length, Code ID, Terminators).

REFERENCES

REFERENCES

4.1
4.1.1

USB-COM AND RS232 PARAMETERS


Handshaking

Hardware handshaking: (RTS/CTS)


The RTS line is activated by the decoder before transmitting a character.
Transmission is possible only if the CTS line (controlled by the Host) is active.
Signals at
EIA levels

RTS

TX
Transmitted data

Transmitted data

Host busy

CTS

RTS/CTS handshaking

Software handshaking: (XON/XOFF)


During transmission, if the Host sends the XOFF character (13 Hex), the decoder
interrupts the transmission with a maximum delay of one character and only resumes
when the XON character (11 Hex) is received.
Transmitted data

Transmitted data

TX

RX
XOFF
Host busy

XON
Host ready

XON/XOFF handshaking

107

HHD II

4.1.2

ACK/NACK Protocol

This parameter sets a transmission protocol in which the Host responds to the reader
after every code transmitted. The Host sends an ACK character (06 HEX) in the case
of good reception or the NACK character (15 HEX) requesting re-transmission, in the
case of bad reception.
If the reader does not receive an ACK or NACK, transmission is ended after the RX
Timeout (see par. 4.1.4).
Selection of the ACK/NACK protocol automatically disables FIFO buffering see par.
4.1.3.

4.1.3

FIFO

This parameter determines whether data (barcodes) are buffered on a First In First
Out basis allowing faster data collection in certain cases for example when using
slow baud rates and/or hardware handshaking.
If the FIFO buffering is enabled, codes are collected and sent out on the serial line in
the order of acquisition. Several hundred characters can be collected (buffer full),
after which the reader signals an error and discards any further codes until the
transmission is restored.
If the FIFO buffering is disabled, each code must be transmitted before another one
can be read.

4.1.4

RX Timeout

When the RS232 interface is selected, the Host can be used to configure the device
by sending it command strings (see appendix A).
This parameter can be used to automatically end data reception from the Host after
the specified period of time.
If no character is received from the Host, after the timeout expires, any incomplete
string (any string not terminated by <CR>) is flushed from the device buffer.

108

REFERENCES

4.2

PEN PARAMETERS

4.2.1

Minimum Output Pulse

This parameter sets the duration of the output pulse corresponding to the narrowest
element in the barcode. In this way the code resolution is controlled by the signal
sent to the decoder, independently of the physical resolution of the code read.
The shortest pulse (200 s) corresponds to high-resolution code emulation and
therefore a shorter transfer speed to the decoder (for decoders able to work on highresolution codes). Likewise, longer pulses correspond to low-resolution code
emulation and therefore a longer transfer time to the decoder.

4.2.2

Conversion to Code 39

When using these readers it is possible to convert all codes to Code 39. By disabling
this option the decoded codes will be transmitted in their original format; except for
the following codes which are ALWAYS converted into Code 39 format:
MSI, Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49 and RSS Codes.

4.2.3

Overflow

This parameter generates a white space before the first bar and after the last bar of
the code. The selections are as follows:
narrow
medium
wide

= space 10 times the minimum output pulse.


= space 20 times the minimum output pulse.
= space 30 times the minimum output pulse.

109

HHD II

4.2.4

Output and Idle Levels

The following state diagrams describe the different output and idle level combinations
for Pen emulation:

idle

bar

OUTPUT: Normal
space

IDLE: Normal

black
white

barcode output
bar

OUTPUT: Normal
idle

space

IDLE: Inverted

black
white

barcode output
space

OUTPUT: Inverted

white

idle

bar

IDLE: Normal

black

barcode output
OUTPUT: Inverted

white

space

idle

bar

IDLE: Inverted

black

barcode output
Output and Idle Levels

4.2.5

Inter-Block Delay

For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20
characters each. The inter-block delay parameter allows setting a delay between
each block sent to the Host.

110

REFERENCES

4.3
4.3.1

IBM 46XX
IBM Data Formatting (Transmission Format)

The IBM 46xx Series cash register recognizes the following codes:

EAN 8 / EAN13 / UPC A / UPC E with and without Add On

Interleaved 2/5

Code 39

Codabar

Code 128

Code 93

Normal 2/5

The transmission format of codes belonging to this set is specified by the protocol. As
the reader allows a wider set of codes to be selected, the following formats are
defined to offer the user all the reading possibilities of the Datalogic product.
Conversion to Code 39 Format
Data from any code selected may be transmitted. Each code is transmitted to the
Host as Code 39. Any character not included in the standard Code 39 set will be
replaced with a Space (20 Hex).
IBM Standard Format
Only codes belonging to the above mentioned set may be transmitted. Each code
transmitted to the Host is recognized by the identifier requested by the protocol. If the
selected code does not belong to this set, it wiII not be transmitted.
Mixed IBM Standard + Code 39 Format
Data from any code selected may be transmitted. For codes belonging to the above
mentioned set, the IBM Standard Format is applied. The Code 39 Format applies
to codes not belonging to this set.

111

HHD II

4.4

DATA FORMAT

4.4.1

Header/Terminator Selection

The header/terminator selection is not effected by the reading of the restore default
code. In fact, header and terminator default values depend on the interface selection:
RS232 and USB-COM:
WEDGE and USB-KBD:
WEDGE ALT-MODE and USB-KBD-ALT-MODE:

no header, terminator CR-LF


no header, terminator ENTER
no header, terminator CR

These default values are always restored through the reading of the relative interface
selection code, see chapter 2.
For the WEDGE interface, the following extended keyboard values can also be
configured:
EXTENDED KEYBOARD TO HEX CONVERSION TABLE
IBM AT
IBM 3153
APPLE ADB

IBM XT

IBM 31xx, 32xx,


34xx, 37xx

Wyse
Digital

HEX

KEY

KEY

KEY

KEY

83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B

ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
HOME
END
PG UP
PG DOWN

ESC
CTRL (Right)
Euro

ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
ESC
BACKSPACE
HOME
END
PG UP
PG DOWN

ESC
CTRL (Right)
Space

FIELD EXIT
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
ENTER
RESET
INSERT
DELETE
FIELD FIELD +
ENTER (Paddle)
PRINT

RETURN
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
UP
DOWN
LEFT
RIGHT
ESC
CTRL (Right)
Space

Space

For all readers using Wedge interface, all values from 9C to FE send the Space character.

112

REFERENCES

4.4.2

Set Custom Extended Header/Terminator Keys

The extended Header/Terminator keys for Wedge Interface users can be


customized by defining them through a simple keyboard setting procedure.
For example, the Numeric Keypad keys can be set for use as Headers or
Terminators by substituting the default extended keys using this procedure.
The type of computer or terminal must be selected before activating the keyboard
setting command.
Press and release a key to set it.
Some characters may require more than one key pressed simultaneously during
normal use (refer to the manual of your PC or terminal for keyboard use). The exact
sequence must be indicated to the reader in this case pressing and releasing the
different keys.
Example:
If one has to press the "Shift" and "4" keys simultaneously on the keyboard to
transmit the character "$" to the video, to set the "$", press and release "Shift" then
press and release "4".
Each pressed and released key must generate an acoustic signal on the reader,
otherwise repress the key. Never press more than one key at the same time, even if
this corresponds to the normal use of your keyboard.
Press "Backspace" to correct a wrong key entry. In this case the reader emits 2
beeps.
Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard
setting procedure. "SHIFT" must be repressed for each character and cannot
be substituted by "CAPS LOCK".

113

Enter Configuration

Exit and Save Configuration

$+;

$-?
Set Custom Extended Header/Terminator Keys

FB1W
Read the code above.

If the first 4 KEYS (Shift, Alt, Ctrl, and Backspace) are not available on your
keyboard, you can only substitute them with keys not used, or substitute them with
each other.
Keys 5 to 28 must be defined

Press the desired keys in the following order:


The reader signals the end of the procedure with 2 beeps indicating the keys have been
registered.

CUSTOM EXTENDED KEYBOARD SETTING TABLE


Custom

114

Order

HEX

KEY

01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A

Shift
Alt
Ctrl
Backspace

REFERENCES

4.5

POWER SAVE

4.5.1

Sleep State/USB Suspend

When using standard devices, this mode allows the P in the reader to enter a
Sleep state for minimum power consumption. This command is only valid when
hardware trigger type is selected.
Before entering Sleep mode, the following are verified:

no commands coming from Host

no data being transmitted to Host

Enter Sleep Timeout ended (see par. 4.5.2)

It is possible to exit Sleep mode either by pressing the button/trigger or by inserting


the reader into the Stand (only for devices with Stand Recognition Beep).
Enabling the Sleep State/USB Suspend implements Standby mode for CCD devices,
see par. 4.5.3.
When using USB devices, this mode allows the device to manage Selective Suspend
conditions generated by the Host Operating System in which optimizing low power
consumption (ex. Windows Stand-by). It is possible to exit the Suspend mode either
from the Host (ex. moving the mouse during Stand-by) or through the barcode
reader. The latter, called Remote Wakeup, makes the device wake up the Host
restoring the communication. Remote Wakeup is possible either by pressing the
button/trigger or by putting the reader into the stand (only for devices with Stand
Recognition Beep).

4.5.2

Enter Sleep Timeout

For readers that have the Sleep state enabled, this timeout determines when the
reader will enter this state.

4.5.3

Standby (only for CCD devices)

If this command is enabled, part of the CCD circuitry shuts down (Standby), in order
to optimize low power consumption when not reading. When the trigger is pressed
this circuitry powers up. This mode causes a minor delay before the reader is ready.

115

HHD II

4.6

READING PARAMETERS

4.6.1

Hand-Held and Stand Operation

These parameter groups allow setting different reading modes for Hand-Held
Operation and Stand Operation:

SoftwareTrigger: the reader is set in FLASH MODE. Code reading takes place
during the flash on time;
Hardware Trigger: the code reading is started with a trigger press (ON);

Hardware Trigger Ready: the illuminator is switched ON when the reader sees
a code. It functions as a pointer aiming at the code to be read. The reading
phase starts only when the trigger is pressed. In this mode the reader is
automatically set to trigger active level and one read per cycle parameters.
(Only for Hand-Held Operation).

Automatic: the illuminator is switched ON when the reader sees a code. The
reading phase starts automatically.

Always ON: the illuminator/laser is always ON and the reader always ready for
code reading.

4.6.2

Hardware Trigger Signal

This parameter determines how the reader ON state is controlled for readers with
button/trigger when Hardware Trigger is selected:

trigger level: the reader goes ON when the trigger is pressed and goes OFF
when it is released

trigger pulse: the reader goes ON at the first trigger press and goes OFF only
at a second press

4.6.3

Trigger-Off Timeout

When this timeout is selected, the reader turns OFF automatically after the desired
period of time.

4.6.4

Reads per Cycle

In general, a reading cycle corresponds to the ON + OFF times of a device. The


resulting effects of this parameter on code reading depend on other related
configuration conditions. Here are the definitions of ON and OFF times.

116

REFERENCES

For readers using the software trigger parameter (FLASH MODE), a reading
cycle corresponds to the flash on + flash off times. Code reading takes place
during the flash on time.

For readers using the hardware trigger parameter, a reading cycle corresponds
to a trigger press (ON) + one of the following OFF events:
trigger release (for trigger active level)
a second trigger press (for trigger active pulse)
trigger-off timeout (see par. 4.6.3).

When one read per cycle is selected, the device decodes only one code during the
ON period and immediately turns the reader OFF. It is only possible to read another
code when the next ON time occurs.
In multiple reads per cycle, the ON period is extended so that the device can
continue decoding codes until an OFF event occurs. For software trigger mode, the
flash on period is immediately reset after each read and therefore extended. If
another code is decoded before the reset flash on period expires, it is again reset
and the effect is that the device remains ON, decoding codes until the flash on or
timeout period expires.
The Safety Time parameter should be used in this case to avoid unwanted multiple
reading of the same code, see par. 4.6.5.

4.6.5

Safety Time

Safety time prevents the device from immediately decoding the same code more
than once. Same code consecutive reading can be disabled requiring the reader to
be removed from the code (no decoding) for at least 400 ms, or a timeout can be set
up to 9.9 seconds before the decoder will accept the same code. Reading is
immediate if the code changes.
For Automatic Hand-Held or Stand Operation, the Safety Time parameter is forced to
no code consecutive reading (00).
The safety time parameter is not applicable when reading stacked codes or when
setting one read per cycle in hardware trigger operating mode, since these settings
require voluntary action by the user.

4.6.6

Automatic Operation Aiming Light

This parameter is valid for CCD long range devices in Automatic Hand-Held or Stand
Operation and allows an aiming light to be continuously emitted in front of the reader
to facilitate the positioning of the barcode to be read.

117

HHD II

4.6.7

Aiming System

This parameter is valid for laser readers and provides a


programmable timeout for the aiming system. If enabled, the scan
line emitted from the reading window is preceded by a red spot
which must illuminate the code center to get the best reading
performance (see figure, ). Once the defined timeout is
reached, the red spot disappears and is followed by the scan line
to start the code scanning.

4.7

DECODING PARAMETERS

CAUTION

4.7.1

These parameters are intended to enhance the decoding capability of


the reader for particular applications. Used incorrectly, they can
degrade the reading performance or increase the possibility of a
decoding error.

Ink-Spread

The ink-spread parameter allows the decoding of codes which are not perfectly
printed because the page texture tends to absorb the ink.

4.7.2

Overflow Control

The overflow control parameter can be disabled when decoding codes printed on
small surfaces, which dont allow the use of an overflow space.
This command does not effect code families 2/5, Code 128 and Code 93.

4.7.3

Interdigit Control

The interdigit control parameter verifies the interdigit spacing for code families Code
39 and Codabar.

118

REFERENCES

4.8

CONFIGURATION EDITING COMMANDS

The following commands carry out their specific function and then exit the
configuration environment.
Command

Description

$+$*o

Restore system default configuration (see the relative


Quick Reference Manual for default settings)

$+$!K

Transmit the Software release. This command is not


effective with the Pen emulation interface.

$+$&_

Transmit the device configuration in ASCII format. This


command is not effective with the Pen emulation
interface.

119

HHD II

4.9

CONFIGURATION COPY COMMAND

Procedure:

Connect the master (correctly configured reader) and the slave (reader to be
configured) together through two RS232 serial interface cables and external
power supply. Accessory cables and power supply are available from your
Datalogic distributor to provide this connection.
RS232 Cables: CAB363 & CAB364 or CAB320 & CAB328
Power Supply: PG5

Using the slave device, read the Restore Default barcode and then the RS232
interface barcode from par. 2.1.2 of this manual or from the Quick Reference
Manual.

With the master device, read the Configuration Copy barcode below.

Copy Configuration

$+ZZ0$-*
The configuration will be copied from the master to the slave device. The slave
device signals the end of the procedure with a series of beeps.
Note: The master device can be configured for any interface.

120

REFERENCES

4.10 DEFAULT PARAMETERS FOR POS SYSTEMS


The default values for the RS232 and Data Format parameters for POS systems are
listed in the following table:

RS232 Group
Baud Rate
Parity
Data Bits
Stop Bits
Handshaking
ACK/NACK Protocol
FIFO
Inter-Character Delay
RX Timeout
Serial Trigger Lock

Data Format Group


Code Identifier
Header
Terminator
Field Adjustment
Code Length TX
Character Replacement

NIXDORF Mode A

FUJITSU

ICL Mode

9600
Odd
8
1
Hardware (RTS/CTS)
Disabled
Disabled
Disabled
9.9 sec
Disabled

9600
None
8
1
None
Disabled
Enabled
Disabled
2 sec
Disabled

9600
Even
8
1
RTS always on
Disabled
Enabled
Disabled
9.9 sec
Disabled

Custom
No Header
CR
Disabled
Not Transmitted
Disabled

Custom
Custom
No Header
No Header
CR
CR
Disabled
Disabled
Not Transmitted Not Transmitted
Disabled
Disabled

The table below lists all the Code Identifiers available for POS systems:
CODE
UPC-A
UPC-E
EAN-8
EAN-13
Code 39
Codabar
Code 128
Interleaved 2 of 5
Code 93
Industrial 2 of 5
UCC/EAN 128
MSI/Plessey
Code 11

NIXDORF Mode A
A0
C0
B
A
M
N
K
I
L
H
P
O
None

FUJITSU
A
E
FF
F
None
None
None
None
None
None
None
None
None

ICL Mode
A
E
FF
F
C [code length]
N [code length]
L [code length]
I [code length]
None
H [code length]
L [code length]
None
None

121

HHD II

4.11 FIRMWARE UPGRADES


Device firmware upgrades can be performed using the DL Sm@rtSet external
Downloader utility tool from your PC either through RS232 or USB communications.
The procedure for downloading is described in the DL Sm@rtSet User's Manual and
in the Help window.
A special case occurs when using USB communications to upgrade devices without
button/trigger.
Procedure:

For devices WITHOUT button/trigger

Launch the Downloader tool from the DL Sm@rtSet folder on your PC.

Connect the device to the PC via USB interface.

Read the code given below to emulate the trigger press:


Trigger Press

#+Upgradex
The device will automatically be reset.

122

Proceed with the firmware upgrade (see the DL Sm@rtSet User's Manual for
details).

HOST CONFIGURATION STRINGS

HOST CONFIGURATION STRINGS

In this section we provide a description of how to modify the device configuration


using serial strings sent from the Host.
This method requires either the RS232 or USB-COM interface.
The device configuration can be changed by receiving commands from the Host
through the serial interface. When this method is used, the programming sequence
format is the following:

$+

Command

$-

CR
Carriage return character (0D Hex.)
Exit and Save configuration

Character sequence in following tables


Enter configuration environment

Example:
Multiple command programming sequence:
$+

BG1 BH0

AC410132

$-

CR

Carriage return character (0D Hex.)


Exit and save new configuration
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
Beeper tone 1
Beeper low intensity
Enter configuration environment

Each configuration parameter setting removes the condition previously active for that
parameter.

NOTE

The device buffer can contain about 400 characters. If your


programming string goes over this value, you must split it into separate
groups and send each group after a delay of at least 3 seconds to give
the reader time to empty the buffer and interpret the commands.

123

HHD II

SERIAL CONFIGURATION STRINGS


ENTER/EXIT CONFIGURATION COMMANDS
DESCRIPTION
Enter Configuration
Exit and Save Configuration
Restore Default
Transmit Software Release (not for PEN emulation)
Transmit Configuration (not for PEN emulation)

STRING
$+
$$+$*
$+$!
$+$&

INTERFACE SELECTION
DESCRIPTION
USB
USB-KBD
USB-KBD-ALT-MODE
USB-KBD-APPLE
USB-COM
USB-IBM-Table Top
USB-IBM-Hand Held
RS232
Standard
ICL Mode
Fujitsu
Nixdorf Mode A
WEDGE
for IBM AT
for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-break keyboard
for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-only keyboard
Keyboard Type for IBM Terminals typewriter
31xx, 32xx, 34xx, 37xx
advanced
for IBM XT
for IBM Terminal 3153
for IBM PC Notebook
for IBM SURE1
for IBM AT - ALT mode
for IBM PC Notebook - ALT mode
for Wyse Terminal - ANSI Keyboard
for Wyse Terminal - PC Keyboard
for Wyse Terminal - ASCII Keyboard
for Wyse Terminal - VT220 style Keyboard
for Digital Terminals VT2xx/3xx/4xx
for Apple ADB Bus
PEN EMULATION
IBM 46xx 4501 Protocol
1520 Protocol

STRING
UA03
UA04
UA05
UA02
UA00
UA01
CP0
CM0
CM1
CM2EC0
CP500
CP501
CP502
FK0
FK1
CP503
CP504
CP505
CP506
CP507
CP508
CP509
CP510
CP511
CP514
CP512
CP513
CP6
CP800
CP801

124

HOST CONFIGURATION STRINGS

USB
DESCRIPTION
USB-COM
Handshaking

ACK/NACK Protocol
FIFO
Inter-character delay (ms)
RX Timeout (100 ms)
Serial Trigger Lock
USB-KBD
Keyboard nationality
(not for USB-KBD-ALT-MODE)

FIFO
Delays
Control Character Emulation

STRING
disable
RTS/CTS
XON/XOFF
RTS always ON
disable
enable
disable
enable

disable
enable

CE0
CE1
CE2
CE3
ER0
ER1
EC0
EC1
CK00 - CK99
CL00 - CL99
CR0
CR1ab

Belgian
English
French
German
Italian
Spanish
Swedish
USA
Japanese
disable
enable
Inter-Character (ms)
Inter-Code (s)
CTRL +Shift + Key
Ctrl + Key

FJ7
FJ4
FJ2
FJ3
FJ1
FJ6
FJ5
FJ0
FJ8
EC0
EC1
CK00 - CK99
FG00 - FG99
FO0
FO1

a = Hex value of the ASCII character from 00 to FE enabling the device trigger;
b = Hex value of the ASCII character from 00 to FE disabling the device trigger;

125

HHD II

RS232
DESCRIPTION
Baud rate

300
600
1200
2400
4800
9600
19200
38400
Parity
none
even
odd
Data bits
7
8
9
Stop bits
1
2
Handshaking
disable
RTS/CTS
XON/XOFF
RTS always ON
ACK/NACK Protocol
disable
enable
FIFO
disable
enable
Inter-character delay (ms)
RX Timeout (100 ms)
Serial Trigger Lock
disable
enable
a = Hex value of the ASCII character from 00 to FE enabling the device trigger;
b = Hex value of the ASCII character from 00 to FE disabling the device trigger;

126

STRING
CD1
CD2
CD3
CD4
CD5
CD6
CD7
CD8
CC0
CC1
CC2
CA0
CA1
CA2
CB0
CB1
CE0
CE1
CE2
CE3
ER0
ER1
EC0
EC1
CK00 - CK99
CL00 - CL99
CR0
CR1ab

HOST CONFIGURATION STRINGS

WEDGE
DESCRIPTION
Keyboard nationality

Caps Lock
Caps Lock Auto-Recognition
(IBM AT compatible only)
Num Lock
Delays
Control Character Emulation

Belgian
English
French
German
Italian
Spanish
Swedish
USA
Japanese (IBM AT compatible only)
caps Lock ON
caps Lock OFF
disable
enable
Toggle Num Lock
Num Lock Unchanged
Inter-Character (ms)
Inter-Code (s)
CTRL +Shift + Key
Ctrl + Key

STRING
FJ7
FJ4
FJ2
FJ3
FJ1
FJ6
FJ5
FJ0
FJ8
FE1
FE0
FP0
FP1
FL1
FL0
CK00 - CK99
FG00 - FG99
FO0
FO1

PEN
DESCRIPTION
Operating mode
Minimum output pulse

Conversion to Code 39
Output level
Idle level
Overflow

Inter-Block Delay (100 ms)

interpret (does not require $+ or $-)


transparent (does not require $+ or $-)
200s
400s
600s
800s
1 ms
1.2 ms
disable conversion to Code 39
enable conversion to Code 39
normal
inverted
normal
inverted
narrow overflow
medium overflow
wide overflow

STRING
$]
$[
DG0
DG1
DG2
DG3
DG4
DG5
DA0
DA1
DD0
DD1
DE0
DE1
DH0
DH1
DH2
CK00-CK99

127

HHD II

IBM 46xx
DESCRIPTION
IBM Data Formatting

Code 39 Format
IBM Standard Format
Mixed IBM Standard + Code 39 Format

STRING
GD0
GD1
GD2

DATA FORMAT
NOT FOR PEN EMULATION INTERFACES
DESCRIPTION
Code Identifier

disable
Datalogic standard
AIM standard
Custom

Custom Code Identifier


Headers

Terminators

no header
one character
two characters
three characters
four characters
five characters
six characters
seven characters
eight characters
no terminator
one character
two characters
three characters
four characters
five characters
six characters
seven characters
eight characters

STRING
EB0
EB1
EB2
EB3
EHabc
EA00
EA01x
EA02xx
EA03xxx
EA04xxxx
EA05xxxxx
EA06xxxxxx
EA07xxxxxxx
EA08xxxxxxxx
EA10
EA11x
EA12xx
EA13xxx
EA14xxxx
EA15xxxxx
EA16xxxxxx
EA17xxxxxxx
EA18xxxxxxxx

a = ASCII character.
b, c, x = HEX values representing an ASCII character.
a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 43.
b = Hex value of the first Custom Code Identifier character from 00 to FE;
FF = disable Code Identifier
c = Hex value of the second Custom Code Identifier character from 00 to FE;
FF = disable second character of Custom Code Identifier
x = Hex value from 00 to FE

128

HOST CONFIGURATION STRINGS

DATA FORMAT (continued)


NOT FOR PEN EMULATION INTERFACES
DESCRIPTION
Code Length Tx

not transmitted
transmitted
transmitted in 4-digit format
disabled
right addition
left addition
right deletion
left deletion

Field Adjustment

Field Adjustment Character


Character Replacement

disable character replacement


first character replacement
second character replacement
third character replacement

STRING
EE0
EE1
EE2
EF0
EFa0d
EFa1d
EFa2d
EFa3d
EGe
EO0
EO1afg
EO2afg
EO3afg

a = ASCII character.
d = a number from the Hex/Numeric Table.
e, f, g = HEX values representing an ASCII character.
a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 43.
d = a number in the range 01 32 from the Hex/Numeric Table
e = Hex value from 00 to FE
f = Hex value of the character to be replaced from 00 to FE
g= Hex value of the new character to insert from 00 to FE
FF = replace with no new character (remove character)

POWER SAVE
DESCRIPTION
Scan Rate

Sleep State/USB Suspend


Enter Sleep Timeout (100 ms)
Standby

Quarter
Half
Maximum
disable
enable
enable
disable

STRING
BT0
BT1
BT2
BQ0
BQ1
BR00-BR99
BM0
BM1

129

HHD II

READING PARAMETERS
DESCRIPTION
Hand-Held Operation

Stand Operation

Hardware Trigger Signal


Trigger-off Timeout (s)
FLASH ON (100 ms)
FLASH OFF (100 ms)
Reads per Cycle
Safety Time (100 ms)
Beeper Intensity

Beeper Tone

Beeper Type
Beeper Length
Good Read Spot Duration

Stand Recognition Beep


Automatic Operation Aiming Light
Aiming System

130

software trigger
hardware trigger
automatic
always on
hardware trigger ready
software trigger
hardware trigger
automatic
always on
trigger active level
trigger active pulse

one read
multiple reads
beeper off
low intensity
medium intensity
high intensity
tone 1
tone 2
tone 3
tone 4
monotone
bitonal
long
short
disable
short
medium
long
disable
enable
disable
enable
disable
300 ms
500 ms
1 sec

STRING
BK0
BK1
BK2
BK3
BK4
BU1
BU3
BU0
BU2
BA0
BA1
BD00 - BD99
BB001 - BB099
BB101 - BB199
BC0
BC1
BE00 - BE99
BG0
BG1
BG2
BG3
BH0
BH1
BH2
BH3
BJ0
BJ1
BI0
BI1
BV0
BV1
BV2
BV3
Ba0
Ba1
Bb0
Bb1
BX0
BX1
BX2
BX3

HOST CONFIGURATION STRINGS

DECODING PARAMETERS
DESCRIPTION
Ink-spread
Overflow control
Interdigit control
Decoding Safety

TM

PuzzleSolver

disable
enable
disable
enable
disable
enable
one read
two reads
three reads
four reads
disable
enable

CODE SELECTION
DESCRIPTION
DISABLE ALL FAMILY CODES
EAN/UPC
disable EAN/UPC family
EAN 8/EAN 13/UPC A/UPC E
without ADD ON
with ADD ON
with and without ADD ON
EAN 8/EAN 13
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
UPC A/UPC E
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
EAN 8 check digit transmission
disable
enable
EAN 13 check digit transmission
disable
enable
UPC A check digit transmission
disable
enable
UPC E check digit transmission
disable
enable
conversions
UPC E to UPC A
UPC E to EAN 13
UPC A to EAN 13
EAN 8 to EAN 13

STRING
AX0
AX1
AW1
AW0
AV0
AV1
ED0
ED1
ED2
ED3
AU0
AU1

STRING
AZ0
AA0
AA1
AA5
AA8
AA3
AAK
AAL
AA6
AA4
AAM
AAN
AA7
AAG0
AAG1
AAH0
AAH1
AAI0
AAI1
AAJ0
AAJ1
AAA
AAB
AAC
AAD

131

HHD II

CODE SELECTION (continued)


DESCRIPTION
ISBN Conversion codes
enable ISBN
enable ISSN
enable ISBN and ISSN
disable ISBN and ISSN
Code 39
disable Code 39 family
Standard
no check digit control
check digit control and transmission
check digit control without transmission
Full ASCII
no check digit control
check digit control and transmission
check digit control without transmission
CIP 39
Code 32
code length
2/5
disable Code 2/5 family
Interleaved 2/5
no check digit control
check digit control and transmission
check digit control without transmission
Normal 2/5 5 bars
no check digit control
check digit control and transmission
check digit control without transmission
Industrial 2/5 (IATA) no check digit control
check digit control and transmission
check digit control without transmission
Matrix 2/5 3 bars
no check digit control
check digit control and transmission
check digit control without transmission
CIP/HR

STRING
AP1
AP2
AP3
AP0
AB0
AB11
AB12
AB13
AB21
AB22
AB23
AB3
AB4
AB*xxxx
AC0
AC11xxxx
AC12xxxx
AC13xxxx
AC21xxxx
AC22xxxx
AC23xxxx
AC31xxxx
AC32xxxx
AC33xxxx
AC41xxxx
AC42xxxx
AC43xxxx
AC5

xxxx = ASCII numbers that define the code length where:

First 2 digits = minimum acceptable code length.


Second 2 digits = maximum acceptable code length.

The minimum code length must always be less than or equal to the maximum. The maximum
code lengths are 99 characters.
Examples:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.

132

HOST CONFIGURATION STRINGS

CODE SELECTION (continued)


DESCRIPTION
Codabar
disable Codabar family
Standard
no start/stop character equality control
nor transmission
no start/stop character equality control
but transmission
start/stop character equality control
but no transmission
start/stop character equality control
and transmission
ABC Codabar
no start/stop character equality control
but transmission
Codabar ABC forced concatenation
code length
start/stop character case in lower case
transmission
upper case
Code 128
disable Code 128 family
enable Code 128 - control without transmission of check digit
enable EAN 128 - control without transmission of check digit
add GS before Code disable
enable
ISBT 128
enable ISBT 128
code length
Code 93
disable Code 93 family
enable Code 93 - control without transmission of check digit
MSI
disable the family
no check
MOD10 no tx
MOD10 with tx
MOD11-MOD10 no tx
MOD11-MOD10 with tx
MOD10-MOD10 no tx
MOD10-MOD10 with tx

STRING
AD0
AD111
AD112
AD121
AD122
AD212
AD232
AD*xxxx
ADA0
ADA1
AI0
AI11
AI21
EQ0
EQ1
AI31
AILxxxx
AK0
AK1
AE0
AE1
AE2
AE3
AE4
AE5
AE6
AE7

xxxx = ASCII numbers that define the code length where:


First 2 digits = minimum acceptable code length.
Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum. The maximum
code lengths are 99 characters.
Examples:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.

133

HHD II

CODE SELECTION (continued)


DESCRIPTION
Plessey

Telepen

Delta IBM

Code 11

Code 16K
Code 49
RSS Codes

134

disable the family


Standard no check
Standard check - with tx
Standard check - no tx
Anker no check
Anker check - with tx
Anker check - no tx
disable the family
Numeric no check
Numeric check - with tx
Numeric check - no tx
Alpha no check
Alpha check - with tx
Alpha check - no tx
disable the family
no check
Type 1 check
Type 2 check
disable the family
no check
Type C with tx
Type C no tx
Type K with tx
Type K no tx
Type C and K with tx
Type C and K no tx
disable
enable
disable
enable
disable the family
disable RSS Expanded Linear and Stacked
enable RSS Expanded Linear and Stacked
disable RSS Limited
enable RSS Limited
disable RSS 14 Linear and Stacked
enable RSS 14 Linear and Stacked

STRING
AF0
AF11
AF12
AF13
AF21
AF22
AF23
AL0
AL11
AL12
AL13
AL21
AL22
AL23
AH0
AH1
AH2
AH3
AG0
AG1
AG21
AG22
AG31
AG32
AG41
AG42
AJ0
AJ1
AM0
AM1
AQ0
AQ10
AQ11
AQ20
AQ21
AQ30
AQ31

CODE IDENTIFIER TABLE

CODE IDENTIFIER TABLE


2/5 Interleaved

NO
2/5 Industrial

PQ
2/5 normal 5 bars

OP
2/5 matrix 3 bars

QR
EAN 8

AB
EAN 13

BC
UPC A

CD
UPC E

DE
EAN 8 with 2 ADD ON

JK
EAN 8 with 5 ADD ON

KL
EAN 13 with 2 ADD ON

LM
EAN 13 with 5 ADD ON

MN
135

HHD II
UPC A with 2 ADD ON

FG
UPC A with 5 ADD ON

GH
UPC E with 2 ADD ON

HI
UPC E with 5 ADD ON

IJ
Code 39

VW
Code 39 Full ASCII

WX
CODABAR

RS
ABC CODABAR

ST
Code 128

TU
EAN 128

kl
ISBT 128

fg
CIP/HR

ef
CIP/39

YZ
136

CODE IDENTIFIER TABLE


Code 32

XY
Code 93

UV
MSI

Z[
Plessey Standard

ab
Plessey Anker

op
Delta IBM

cd
Telepen

de
Code 16K

pq
Code 11

bc
Code 49

qr
RSS Expanded Linear and Stacked

tu
RSS Limited

vw
RSS 14 Linear and Stacked

uv
137

HEX AND NUMERIC TABLE


CHARACTER TO HEX CONVERSION TABLE
char

hex

char

hex

char

hex

NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
SPACE
!
"
#
$
%
&
'
(
)

00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29

*
+
,
.
/
0
1
2
3
4
5
6
7
8
9
:
;
<
=
>
?
@
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T

2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54

U
V
W
X
Y
Z
[
\
]
^
_
`
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z
{
|
}
~
DEL

55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F

HEX AND NUMERIC TABLE

HEX / NUMERIC TABLE


CHARACTER TO HEX CONVERSION TABLE
char

hex

char

hex

char

hex

80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9

AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4

Reserved
Reserved

D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF

ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
HOME
END
Pg UP
Pg Down

ESC
CTRL(Right)

NBSP

01
0

12
1

23
2

34
3

45
4

56
5

67
6

78
7

89
8

9:
9

AB
A

BC
B

CD
C

DE
D

EF
E

FG
F
Backspace

$%/
Cancels an incomplete configuration sequence

HEX AND NUMERIC TABLE

HEX / NUMERIC TABLE


CHARACTER TO HEX CONVERSION TABLE
char

hex

char

hex

char

hex

80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9

AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4

Reserved
Reserved

D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF

ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
HOME
END
Pg UP
Pg Down

ESC
CTRL(Right)

NBSP

01
0

12
1

23
2

34
3

45
4

56
5

67
6

78
7

89
8

9:
9

AB
A

BC
B

CD
C

DE
D

EF
E

FG
F
Backspace

$%/
Cancels an incomplete configuration sequence

Australia

Japan

Datalogic Scanning Pty Ltd


Telephone: [61] (2) 9870 3200
australia.scanning@datalogic.com

Datalogic Scanning KK
Telephone: 81 (0)3 3491 6761
japan.scanning@datalogic.com

France and Benelux

Latin America

Datalogic Scanning Sarl


Telephone: [33].01.64.86.71.00
france.scanning@datalogic.com

Datalogic Scanning, Inc


Telephone: (305) 591-3222
latinamerica.scanning@datalogic.com

Germany

Singapore

Datalogic Scanning GmbH


Telephone: 49 (0) 61 51/93 58-0
germany.scanning@datalogic.com

Datalogic Scanning Singapore PTE LTD


Telephone: (65) 6435-1311
singapore.scanning@datalogic.com

India

Spain and Portugal

Datalogic Scanning India


Telephone: 91- 22 - 64504739
india.scanning@datalogic.com

Datalogic Scanning Sarl Sucursal en Espaa


Telephone: 34 91 746 28 60
spain.scanning@datalogic.com

Italy

United Kingdom

Datalogic Scanning SpA


Telephone: [39] (0) 39/62903.1
italy.scanning@datalogic.com

Datalogic Scanning LTD


Telephone: 44 (0) 1923 809500
uk.scanning@datalogic.com

www.scanning.datalogic.com
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140

2009 Datalogic Scanning, Inc.

90ACC1877 (Rev. E)