Вы находитесь на странице: 1из 26

9

Chapter 9

Specifications
9-1
9-2
9-3

Inverter Specifications
Specifications of Accessories
Option Specifications

Chapter 9

Specifications
9-1

Inverter Specifications

3-phase
p
200-V
V AC
models

Singleg
phase
h
200-V AC
models

Model 3G3JVPower
Rated voltage and
supply frequency
Allowable voltage
fluctuation
Allowable
frequency
fluctuation
Power supply capacity (kVA)
(See note 1.)
Heat radiation (W)
Weight (kg)
Cooling method

Model 3G3JVPower
Rated voltage and
supply frequency
Allowable voltage
fluctuation
Allowable
frequency
fluctuation
Power supply capacity (kVA)
(See note 1.)
Heat radiation (W)
(See note 2.)
Weight (kg)
Cooling method

Max. applicable motor capacity (kW)


Output
p
Rated output capacity (kVA)
specifiifi
Rated output current (A)
cations
Rated output voltage (V)
Max. output frequency
Control
Harmonic-current
characcharac
countermeasures
teristics
Control method
Carrier frequency
Frequency control range
Frequency precision
(temperature characteristics)
Frequency setting resolution

Output frequency resolution

9-2

A2001

A2002

A2004

A2007

A2015

A2022

A2037

5.9

9.3

94.8
1.5

149.1
2.1

3-phase 200 to 230 V AC at 50/60 Hz


15% to 10%
5%

0.4

0.9

13.0
18.0
0.5
0.5
Natural cooling

1.6

2.7

4.3

28.1
0.8

45.1
72.8
0.9
1.3
Cooling fan

AB001 AB002 AB004 AB007 AB015

---

---

Single-phase 200 to 240 V AC at 50/60 Hz


15% to 10%
5%

0.5

0.9

1.6

2.7

4.3

---

---

14.1

20.0

31.9

51.4

82.8

---

---

0.9

1.5

1.5
--Cooling fan

---

0.5
0.5
Natural cooling

0.1
0.2
0.4
0.75
1.5
2.2
3.7
0.3
0.6
1.1
1.9
3.0
4.2
6.7
0.8
1.6
3.0
5.0
8.0
11.0
17.5
3-phase 200 to 240 V AC (according to the input voltage)
400 Hz parameter setting
DC reactor (option) connection possible
Sine wave PWM (V/f control)
2.5 to 10.0 kHz (in vector control)
0.1 to 400 Hz
Digital commands: 0.01% (10C to 50C)
Analog commands: 0.5% (25C 10C)
Digital commands: 0.1 Hz (less than 100 Hz) and 1 Hz (100
Hz or over)
Analog commands: 0.06 Hz/60 Hz (equivalent to 1/1000)
0.01 Hz

Chapter 9

Specifications
Control
h
characteristics

Overload capacity
External frequency set
signal
Acceleration/deceleration
time
Braking torque

Voltage/frequency
characteristics
ProtecMotor protection
tive
i ffunc- Instantaneous overcurrent
tions
protection
Overload protection
Overvoltage protection
Undervoltage protection

Environment

Momentary power
interruption compensation
(selection)
Cooling fin overheating
Grounding protection
Charge indicator (RUN
indicator)
Location
Ambient temperature
Ambient humidity
Ambient temperature
Altitude
Insulation resistance
Vibration resistance

Degree of protection

150% of rated output current for 1 min


Selectable with FREQ adjuster: 0 to 10 V DC (20 k), 4 to 20
mA (250 ), and 0 to 20 mA (250 )
0.0 to 999 s (Independent acceleration and deceleration time
settings: 2 types)
Approx. 20% (Braking Resistor and Braking Unit cannot be
connected.)
Set a user V/f pattern
Protection by electronic thermal
Stops at approx. 250% of rated output current
Stops in 1 min at approximately 150% of rated output current
Stops when main-circuit DC voltage is approximately 410 V
Stops when main-circuit DC voltage is approximately 200 V
(160 V for single-phase 200-V AC model)
Stops for 15 ms or more. By setting the Inverter to momentary
power interruption mode, operation can be continued if power
is restored within approximately 0.5 s.
Detects at 110C 10C
Protection at rated output current level
Lit when the main circuit DC voltage is approximately 50 V or
less.
Indoors (with no corrosive gas, oil spray, or metallic dust)
Operating: 10C to 50C
Operating: 95% max. (with no condensation)
20C to 60C
1,000 m max.
5 M min. (Do not carry out any insulation resistance or
withstand voltage tests)
9.8 m/s2 max. between 10 to 20 Hz
2.0 m/s2 max. between 20 and 50 Hz
Panel-mounting models: Conforms to IP20

Note 1. The power supply capacity is the capacity for the Inverters rated output. It will vary depending
on the impedance at the input power supply. (This is due to fluctuations in the power factor.
The power factor can be improved by inserting an AC reactor.) There will also be variations in
the ratio between the rated current of the motor that is used and the rated output current of the
Inverter.
Note 2. The heat radiation is the electric power consumed in the Inverter at the Inverters rated output.

9-3

Chapter 9

Specifications
3-phase
p
400 V AC
400-V
models

Model 3G3JVPower
Rated voltage and
supply frequency
Allowable voltage
fluctuation
Allowable
frequency
fluctuation
Power supply capacity (kVA)
(See note 1.)
Heat radiation (W)
(See note 2.)
Weight (kg)
Cooling method

Max. applicable motor capacity (kW)


Output
p
Rated output capacity (kVA)
specifiifi
Rated output current (A)
cations
Rated output voltage (V)
Max. output frequency
Control
Harmonic-current
characcharac
countermeasures
teristics
Control method
Carrier frequency
Frequency control range
Frequency precision
(temperature characteristics)
Frequency setting resolution

Output frequency resolution


Overload capacity
External frequency set
signal
Acceleration/deceleration
time
Braking torque
Voltage/frequency
characteristics

9-4

A4002

A4004

A4007

A4015

A4022

A4037

3-phase 380 to 460 V AC at 50/60 Hz


15% to 10%
5%

1.3

1.9

3.6

5.1

5.9

9.1

23.1

30.1

54.9

75.7

83.0

117.9

1.5

1.5
1.5
Cooling fan

1.0
1.1
Natural cooling

2.1

0.2
0.4
0.75
1.5
2.2
3.7
0.9
1.4
2.6
3.7
4.2
6.6
1.2
1.8
3.4
4.8
5.5
8.6
3-phase 380 to 460 V AC (according to the input voltage)
400 Hz parameter setting
DC reactor (option) connection possible
Sine wave PWM (V/f control)
2.5 to 10.0 kHz (in vector control)
0.1 to 400 Hz
Digital commands: 0.01% (10C to 50C)
Analog commands: 0.5% (25C 10C)
Digital commands: 0.1 Hz (less than 100 Hz) and 1 Hz
(100 Hz or over)
Analog commands: 0.06 Hz/60 Hz (equivalent to 1/1000)
0.01 Hz
150% of rated output current for 1 min
Selectable with FREQ adjuster: 0 to 10 V DC (20 k), 4 to
20 mA (250 ), and 0 to 20 mA (250 )
0.0 to 999 s (Independent acceleration and deceleration time
settings: 2 types)
Approx. 20% (Braking Resistor and Braking Unit cannot be
connected.)
Set a user V/f pattern

Chapter 9

Specifications
ProtecMotor protection
i funcf
tive
Instantaneous overcurrent
tions
protection
Overload protection
Overvoltage protection
Undervoltage protection
Momentary power
interruption compensation
(selection)
Cooling fin overheating
Grounding protection
Charge indicator (RUN
indicator)
Environ- Location
ment
Ambient temperature
Ambient humidity
Ambient temperature
Altitude
Insulation resistance
Vibration resistance
Degree of protection

Protection by electronic thermal


Stops at approx. 250% of rated output current
Stops in 1 min at approximately 150% of rated output current
Stops when main-circuit DC voltage is approximately 820 V
Stops when main-circuit DC voltage is approximately 400 V
Stops for 15 ms or more. By setting the Inverter to momentary
power interruption mode, operation can be continued if power
is restored within approximately 0.5 s.
Detects at 110C 10C
Protection at rated output current level
Lit when the main circuit DC voltage is approximately 50 V or
less.
Indoors (with no corrosive gas, oil spray, or metallic dust)
Operating: 10C to 50C
Operating: 95% max. (with no condensation)
20C to 60C
1,000 m max.
5 M min. (Do not carry out any insulation resistance or
withstand voltage tests)
9.8 m/s2 max. between 10 to 20 Hz
2.0 m/s2 max. between 20 and 50 Hz
Panel-mounting models: Conforms to IP20

Note 1. The power supply capacity is the capacity for the Inverters rated output. It will vary depending
on the impedance at the input power supply. (This is due to fluctuations in the power factor.
The power factor can be improved by inserting an AC reactor.) There will also be variations in
the ratio between the rated current of the motor that is used and the rated output current of the
Inverter.
Note 2. The heat radiation is the electric power consumed in the Inverter at the Inverters rated output.

9-5

Chapter 9

Specifications
9-2

Specifications of Accessories

9-2-1 List of Accessories


H Mounting Accessories
Name
Adapter Panel (for 3G3JV
Series)

Model
3G3JV-PSI232Jj

RS-422/485
Communications Unit

3G3JV-PSI485J

Fan Unit

3G3IV-PFANj

Description
Interface required to connect a Digital Operator to
a 3G3JV Inverter. There are two types of Adapter
Panels available: a fixed type (3G3JV-PSI232J)
and a detachable type (3G3JV-PSI232JC). Use
the detachable type for copying parameters.
Interface required to perform RS-422/485
general-purpose communications. The
communications protocol conforms to MODBUS
(same protocol as 3G3MV and 3G3RV Inverters).
Replacement for the existing cooling fan of the
Inverter.
Replace the cooling fan if it has reached the end
of its service life or a warning of cooling fan
failure (FAN) is indicated.

H Separate Accessory
Name
Scaling Meter

9-6

Model
K3TJ-V11j

Description
Connected to the analog monitor output of the
Inverter.
The Scaling Meter displays the rpm or speed of
the machine or line in actual units.

Chapter 9

Specifications
H Dedicated Accessories
Name
Digital Operator (with
adjuster)

Model
3G3IV-PJVOP140

Digital Operator (without


adjuster)

3G3IV-PJVOP146

Digital Operator Case (for


3G3IV-PJVOP140)

3G3IV-PEZZ08386A

Digital Operator
Connection Cable
DC Reactor

3G3IV-PCN126/326

DIN Track Mounting


Bracket

3G3IV-PEZZ08122j

3G3HV-PUZDABj

Description
Operator used to perform operations for 3G3JV
and 3G3MV Inverters. It is identical to the Digital
Operator attached to standard 3G3MV Inverters,
and has a built-in EEPROM in which the
Inverters parameter settings can be stored. If the
Digital Operator Case (3G3IV-PEZZ08386A) is
used, the Inverter can be mounted in a control
panel, or operated by remote control.
Operator used to perform operations for 3G3JV
and 3G3MV Inverters by remote control. It has a
built-in EEPROM in which the Inverters
parameter settings can be stored.
Case for 3G3IV-PJVOP140 Digital Operator.
Mounting a 3G3IV-PJVOP140 in the Case allows
the Inverter to mounted in a control panel, or
operated by remote control.
Required when using a Digital Operator with
3G3JV Inverters. Cable length: 1 m, 3 m.
Suppresses harmonic current generated from the
Inverter and improves the power factor of the
Inverter.
An adapter making it possible to easily mount the
Inverter to DIN tracks.

H Recommendable Separate Accessories


Name
AC Reactor (Yaskawa
Electric)

Model
3G3IV-PUZBABj

EMC-conforming Input
Noise Filter (Rasmi)

3G3IV-PRSj

Simple Input Noise Filter


(Yaskawa Electric)

3G3EV-PLNFDj

Output Noise Filter (Tokin)

3G3IV-PLFj

Description
Suppresses harmonic current generated from the
Inverter and improves the power factor of the
Inverter. Connect the AC Reactor to the Inverter if
the capacity of the power supply is much larger
than that of the Inverter.
A Noise Filter on the input side meeting the EC
Directives EMC requirements.
The top of the Noise Filter has mounting screw
holes with which the Inverter mounted to the Noise
Filter can be secured.
Each of these Filters connected to the power input
side eliminates noise in the power line connected to
the Inverter and suppresses noise leaking from the
Inverter to the power line.
Connect this Filter to the output side of the Inverter
to suppress the noise generated by the Inverter
from being transmitted to the output line.

9-7

Chapter 9

Specifications
9-2-2 Adapter Panel
H 3G3JV-PSI232Jj

An Adapter Panel is required as an interface to connect a Digital Operator (3G3IV-PJVOP140 or 3G3IVPJVOP146) to the 3G3JV Inverter.
There are two models of Adapter Panel available. The 3G3JV-PSI232J is permanently installed and
cannot be removed and the 3G3JV-PSI232JC for copying parameters is installed so that it can be
removed.

H Connections
3G3JV
Inverter

Adapter Panel
3G3JV-PSI232J (permanent)
3G3JV-PSI232JC (removeable)

Digital Operator Connection


Cable
3G3IV-PCN126 (1 m)
3G3IV-PCN326 (3 m)

H Dimensions (mm)
D 3G3JV-PSI232J (Permanent)

9-8

Digital Operator
3G3IV-PJVOP146
3G3IV-PJVOP140 + 3G3IVPEZZ08386A (Digital Operator Case)

Specifications

Chapter 9

D 3G3JV-PSI232JC (Removeable)

9-2-3 RS-422/485 Communications Unit


H 3G3JV-PSI485J
The RS-422/485 Communications Unit (3G3JV-PSI485J) functions as an interface for RS-422/485
general-purpose communications. The communications protocol conforms to MODBUS (same protocol as 3G3MV and 3G3RV Inverters). Communications can be used for Inverter control inputs, frequency references, monitoring Inverter operating status, and reading/writing parameter settings.
Note Refer to Section 7 Communications for details.

H Dimensions (mm)

9-9

Chapter 9

Specifications
9-2-4 Fan Unit
H 3G3IV-PFANj
The Fan Unit is a replacement for the presently installed cooling fan of the Inverter.

Replace the cooling fan if it has reached the end of its service life or a warning of cooling fan failure
(FAN) is indicated.

H Applicable Models
3-phase 200 V AC

Single-phase 200 V AC
3-phase 400 V AC

Inverter
3G3JV-A2007
3G3JV-A2015/-A2022
3G3JV-A2037
3G3JV-AB015
3G3JV-A4015/-A4022
3G3JV-A4037

Fan Unit
3G3IV-PFAN2007
3G3IV-PFAN2015J
3G3IV-PFAN2037
3G3IV-PFAN2015J
3G3IV-PFAN2015J
3G3IV-PFAN2037

H Replacement Method
Refer to 8-3 Maintenance and Inspection.

9-2-5 Scaling Meter


H K3TJ-V11j
The Scaling Meter is connected to the analog monitor output of the Inverter so that the Scaling Meter
will display the rpm and speed values of the machines and lines in actual units.

H Applicable Models
Model
K3TJ-V111R
K3TJ-V111G
K3TJ-V116R
K3TJ-V116G

Control power supply


100 to 200 V AC
24 V DC insulated construction
(
(see
note))

Indicator
Red LED
Green LED
Red LED
Green LED

Note The power supply circuit and input circuit are insulated from each other.

9-10

Chapter 9

Specifications
H Standard Specifications
Sampling cycle
Display refresh cycle
Average processing method
Number of average processing times
Max. number of display digits
Indicator
Decimal point display
Scaling method

2 times/s
2 times/s
Simple or continuous average processing
1, 2, 4, or 8
4 (9999 to 9999)
14.2-mm-high 7-segment LED
Parameter selector or Up and Down Keys
Parameter selector or Up and Down Keys for shifting and
scaling adjustments
1,999 to +9,999
0 to 99 digits
Flashing
Available
Present value hold (with rear terminals shorted)
Front panel: IP51 (see note)
Casing: IP20
Terminals: IP00
Nonvolatile memory

Scaling range
Zero-limit range
Over range
Zero suppress
External control
Degree of protection
(conforming to IEC)
Memory protection

Note The front panel ensures IP50, but the front panel with the K32-L493C Drip-proof Cover ensures
IP51.

H Wiring Example
Circuit breaker

Inverters internal
circuitry

Three-phase
power supply

Analog output
0 to 10 VDC
Analog
monitor

K3TJ

H External Dimensions (mm)

92

Recommended panel cutout

Weight: 200 g

Display LED size

9-11

Chapter 9

Specifications
9-2-6 Digital Operator
H 3G3IV-PJVOP140/PJVOP146

The Digital Operator (3G3IV-PJVOP140/PJVOP146) is used to control the Inverter from a distance.
There are two models available. The 3G3IV-PJVOP140 is equipped with an adjuster and the 3G3IVPJVOP146 is not.
Always use the 3G3IV-PJVOP140 together with a Digital Operator Case (3G3IV-PEZZ08386A). Without the Case, the Digital Operators connection cable cannot be wired. Using the Case also enables
mounting to a control panel.
Note When a Digital Operator is connected, the Operator on the Inverter cannot be used to control
operation (i.e., only display functions will work).

H Dimensions (mm)
D 3G3IV-PJVOP140 (with Adjuster)
8 max.

3.6 dia

D 3G3IV-PJVOP146 (without Adjuster)


Four, 4.4-dia. mounting holes

Four depressions for


M4 bolts (Depth: 3.5)

9-12

Chapter 9

Specifications
9-2-7 Digital Operator Case
H 3G3IV-PEZZ08386A

The Digital Operator Case (3G3IV-PEZZ08386A) is used to secure the 3G3IV-PJVOP140 Digital Operator. Without this Case, the Digital Operators connection cable cannot be wired. Always use the 3G3IVPJVOP140 and the Digital Operator Case together.

H Dimensions (mm)
Four, 4.4-dia. mounting holes

Four depressions for


M4 bolts (Depth: 3.5)

9-2-8 Digital Operator Connection Cable


H 3G3IV-PCN126/PCN326
The Digital Operator Connection Cable (3G3IV-PCN126/PCN326) is required to connect a Digital
Operator to a 3G3JV Inverter.

H Models and Specifications


Digital Operator Connection Cable
3G3IV-PCN126
3G3IV-PCN326

Cable length
1m
3m

9-2-9 DC Reactor
H 3G3HV-PUZDABj
The DC Reactor suppresses harmonic current generated from the Inverter and improves the power factor of
the Inverter. The DC Reactor suppresses harmonic current more effectively than the AC Reactor. Furthermore,
the DC Reactor can be used in combination with the AC
Reactor.

9-13

Chapter 9

Specifications
H Applicable Model
Inverter
Voltage
Max. applicaclass
ble motor capacity (kW)
200 V
0.1 to 0.75
1.5 to 3.7
400 V
0.2 to 0.75
1.5 to 2.2
3.7

DC Reactor
Rated
Rated
voltage
current
(V)
(A)
800 V DC 5.4
18
800 V DC 3.2
5.7
12

Model

3G3HV-PUZDAB5.4A8MH
3G3HV-PUZDAB18A3MH
3G3HV-PUZDAB3.2A28MH
3G3HV-PUZDAB5.7A11MH
3G3HV-PUZDAB12A6.3MH

Inductance
(mH)
8
3
28
11
6.3

Loss (W)

8
18
9
11
16

H External Dimensions (mm)


External Dimension 1

External Dimension 2
Two, d2
mounting holes

Two, d1
mounting holes
Four, d1
mounting holes

Model
3G3HV3G3HV
PUZDABj
5.4A8MH
18A3MH
3.2A28MH
5.7A11MH
12A6.3MH

External
dimen
dimension
1
2
1
1
2

Dimension (mm)
H
53
76
53
60
76

W
85
86
85
90
86

W1
74
60
74
80
60

D
60
72
60
60
72

D1
32
55
32
32
55

D2
--80
----80

t
0.8
1.2
0.8
0.8
1.2

9-2-10 DIN Track Mounting Bracket


H 3G3IV-PEZZ08122j
An adapter making it possible to easily mount the Inverter to DIN tracks.

9-14

d1
M4
M4
M4
M4
M4

d2
--M5
----M5

Weight
(kg)
0.8
2.0
0.8
1.0
2.0

Chapter 9

Specifications
H Applicable Model
Inverter
3-phase 200 V AC

Single-phase
g
200 V AC
3-phase 400 V AC

3G3JV-A2001/-A2002/-A2004/-A2007
3G3JV-A2015/-A2022
3G3JV-A2037
3G3JV-AB001/-AB002/-AB004
3G3JV-AB007/-AB015
3G3JV-A4002/-A4004/-A4007/-A4015/-A4022
3G3JV-A4037

DIN Track Mounting


Bracket
3G3IV-PEZZ08122A
3G3IV-PEZZ08122B
3G3IV-PEZZ08122C
3G3IV-PEZZ08122A
3G3IV-PEZZ08122B
3G3IV-PEZZ08122B
3G3IV-PEZZ08122C

H External Dimensions (mm)

(35.1)

Four, M4 tap

DIN track

(35.1)

3G3IV-PEZZ08122B

DIN track

3G3IV-PEZZ08122A

Four, M4 tap

3G3IV-PEZZ08122C
6

DIN track

(35.1)

1.6

Four, M4 tap

9-15

Chapter 9

Specifications
9-2-11 AC Reactor
H 3G3IV-PUZBABj (Yaskawa Electric)

The AC Reactor suppresses harmonic current generated from the Inverter and improves the power factor of the Inverter. Connect the AC Reactor to the Inverter if the capacity of the power supply is much
larger than that of the Inverter. Select the AC Reactor model from the following table according to the
motor capacity.

H Connection Example
MCCB AC Reactor
Motor

H Applicable Range
AC Reactor required
for smooth operation
under present power
supply conditions
Power supply
capacity (kVA)
AC Reactor
not required

Inverter capacity (kVA)

H Applicable Models and Dimensions


D 200-V Class
Max. applicable
motor capacity (kW)
0.1 to 0.2
0.4
0.75
1.5
2.2
3.7

9-16

Model
3G3IVPUZBABj
2A7.0MH
2.5A4.2MH
5A2.1MH
10A1.1MH
15A0.71MH
20A0.53MH

Current (A)

2
2.5
5
10
15
20

Inductance
(mH)
7.0
4.2
2.1
1.1
0.71
0.53

Loss (W)

8
15
15
25
30
35

Weight (kg)

2.5
2.5
2.5
3
3
3

Chapter 9

Specifications
Model
3G3IV3G3IV
PUZBABj
2A7.0MH
2.5A4.2MH
5A2.1MH
10A1.1MH
15A0.71MH
20A0.53MH

Dimension (mm)
A

120
120
120
130
130
130

71
71
71
88
88
88
(See
note.)

115
120
120
130
130
105

40
40
40
50
50
50

50
50
50
65
65
65

105
105
105
130
130
130

20
20
20
22
22
22

J
M6
M6
M6
M6
M6
M6

K
10.5
10.5
10.5
11.5
11.5
11.5

L
7
7
7
7
7
7

M
M4
M4
M4
M4
M4
M5

Note B1 = 114

D 400-V Class
Max. applicable
motor capacity (kW)
0.2 to 0.4
0.75
1.5
2.2
3.7
Model
3G3IV3G3IV
PUZBABj

1.3A18.0MH
2.5A8.4MH
5A4.2MH
7.5A3.6MH
10A2.2MH

Model
3G3IVPUZBABj
1.3A18.0MH
2.5A8.4MH
5A4.2MH
7.5A3.6MH
10A2.2MH

Current (A)

1.3
2.5
5
7.5
10

Inductance
(mH)
18.0
8.4
4.2
3.6
2.2

Loss (W)

15
15
25
35
43

Weight (kg)

2.5
2.5
3
3
3

Dimension (mm)
A

120

71

120

40

50

105

20

M6

10.5

M4

120

71

120

40

50

105

20

M6

10.5

M4

130

88

130

50

70

130

22

M6

M4

130

88

130

50

70

130

22

M6

M4

130

88

130

50

65

130

22

M6

11.5

M4

Dimensions
3G3IV-PUZBAB20A0.53MH

All models except 3G3IV-PUZBAB20A0.53MH

M Terminal

M Terminal

Nameplate

Nameplate

Mounting Dimensions
Mounting Dimensions

4-J mounting bolt

4-J mounting bolt

9-17

Chapter 9

Specifications
9-3

Option Specifications

9-3-1 EMC-compatible Noise Filter


Be sure to select an optimum Noise Filter from the following so that the Inverter will satisfy EMC directive requirements of the EC Directives.
Connect the Noise Filter between the power supply and the input terminals (R/L1, S/L2, and T/L3) of
the Inverter.
The Inverter can be mounted to the upper side of the Noise Filter because the upper side of the Noise
Filter incorporates mounting holes for the Inverter.

H Standard Specifications
Noise Filters for 3-phase 200 V AC Inverter Models
Inverter
Model 3G3JVA2001/A2002/A2004/A2007
A2015/A2022
A2037

Noise Filter (Rasmi) for 3-phase 200 V AC Inverter models


Model 3G3JVRated current (A)
Weight (kg)
PRS2010J
10
0.8
PRS2020J
16
1.0
PRS2030J
26
1.3

Noise Filters for Single-phase 200 V AC Inverter Models


Inverter
Model 3G3JVAB001/AB002/AB004
AB007/AB015

Noise Filter (Rasmi) for single-phase 200 V AC Inverter models


Model 3G3JVRated current (A)
Weight (kg)
PRS1010J
10
0.6
PRS1020J
20
1.0

Noise Filters for 3-phase 400 V AC Inverter Models


Inverter
Model 3G3JVA4002/A4004
A4007/A4015/A4022
A4037

Noise Filter (Rasmi) for 3-phase 200 V AC Inverter models


Model 3G3JVRated current (A)
Weight (kg)
PRS3005J
5
1.0
PRS3010J
10
1.0
PRS3020J
15
1.1

H Connection Example
MCCBs

3-phase 200 V AC or
single-phase 200 V AC
3-phase 400 V AC

9-18

Noise Filter

Clamp core

Chapter 9

Specifications
H External Dimensions
Noise Filters for 3-phase 200 V AC Inverter Models
D 3G3JV-PRS2010J

Three, 5-dia. holes


Two, M4 holes
(for Inverter mounting use)
1

1.2

21

D 3G3JV-PRS2020J

Three, 5-dia. holes

Four, M4 holes
(for Inverter mounting use)

1.2

21

9-19

Chapter 9

Specifications
D 3G3JV-PRS2030J
174
161
Three, 5-dia. holes

118

Four, M4 holes
(for Inverter mounting use)

120

128

144

135

25

1.2

50

26

Noise Filters for Single-phase 200-V AC Models


D 3G3JV-PRS1010J

Three, 5-dia. holes

Two, M4 holes
(for Inverter mounting use)
1

1.2

21

9-20

Chapter 9

Specifications
D 3G3JV-PRS1020J

Three, 5-dia holes

Four, M4 holes
(for Inverter mounting use)

1.2

21

Noise Filters for 3-phase 400-V AC Models


D 3G3JV-PRS3005J
169
156
Three, 5-dia. holes

91

96

21

135

25

1.2

50

111

Four, M4 holes
(for Inverter mounting use)

118

9-21

Chapter 9

Specifications
D 3G3JV-PRS3010J
169
156
Three, 5-dia. holes

91

96

111

Four, M4 holes
(for Inverter mounting use)

118

135

9-22

25

1.2

50

21

Chapter 9

Specifications
D 3G3JV-PRS3020J
174
161
Three, 5-dia. holes

118

Four, M4 holes
(for Inverter mounting use)

120

128

144

135

25

1.2

50

26

9-3-2 Simple Input Noise Filter


H 3G3EV-PLNGFj (Yaskawa Electric)
The Simple Input Noise Filter is connected to the power input side to eliminate the noise in the power line
connected to the Inverter and suppress noise leaking
from the Inverter to the power line.

9-23

Chapter 9

Specifications
H Applicable Models
Inverter
Voltage

Model

3-phase 200 V 3G3JV-A2001/-A2002/-A2004/-A2007


AC
3G3JV-A2015
3G3JV-A2022
3G3JV-A2037
Single-phase
g
3G3JV-AB001/-AB002
200 V AC
3G3JV-AB004
3G3JV-AB007
3G3JV-AB015
3-phase 400 V 3G3JV-A4002/-A4004/-A4007
AC
3G3JV-A4015/-A4022
3G3JV-A4037

Simple Input Noise Filter


Model
Rated current Weight (kg)
3G3EV(A)
PLNFD2103DY 10
0.2
PLNFD2153DY 15
0.2
PLNFD2203DY 20
0.4
PLNFD2303DY 30
0.5
PLNFB2102DY 10
0.1
PLNFB2152DY 15
0.2
PLNFB2202DY 20
0.2
PLNFB2302DY 30
0.3
PLNFD4053DY 5
0.3
PLNFD4103DY 10
0.4
PLNFD4153DY 15
0.4

H Connection Example
3-phase input
Noise filter

9-24

Single-phase input
Noise filter

Chapter 9

Specifications
H Dimensions
Dimensions 1
(Single-phase Input)

Model
3G3EVG EV
PLNFD2103DY
PLNFD2153DY
PLNFD2203DY
PLNFD2303DY
PLNFB2102DY
PLNFB2152DY
PLNFB2202DY
PLNFB2302DY
PLNFD4053DY
PLNFD4103DY
PLNFD4153DY

Dimension (mm)

Figure
g
((above)
b
)
2

3
1

Dimensions 3
(Three-phase Input)

Dimensions 2
(Three-phase Input)

W
120
120
170
170
120
120
120
130
170
170
170

D
80
80
90
110
80
80
80
90
130
130
130

H max.
55
55
70
70
50
50
50
65
75
95
95

A
108
108
158
--108
108
108
118
-------

A
------79
--------79
79
79

B
68
68
78
98
68
68
68
78
118
118
118

Mounting
screw
M4 4, 20 mm
M4 4, 20 mm
M4 4, 20 mm
M4 6, 20 mm
M4 4, 20 mm
M4 4, 20 mm
M4 4, 20 mm
M4 4, 20 mm
M4 6, 30 mm
M4 6, 30 mm
M4 6, 30 mm

9-3-3 Output Noise Filter


H 3G3IV-PLFj (Tokin)
The Output Noise Filter suppresses the generated noise of the Inverter from being transmitted to the
output line. Connect the Output Noise Filter to the output side of the Inverter.

9-25

Chapter 9

Specifications
H Connection Example
Noise filter

H Applicable Models
Voltage class

200-V class

400-V class

Inverter
Max. applicable
motor capacity
(kW)
0.1
0.2
0.4
0.75
1.5
2.2
3.7
0.2
0.4
0.75
1.5
2.2
3.7

Output Noise Filter


Model
Rated current (A)

Inverter capacity
(kVA)
0.3
0.6
1.1
1.9
3.0
4.2
6.7
0.9
1.4
2.6
3.7
4.2
6.5

3G3IV-PLF310KA

10

3G3IV-PLF320KA

20

3G3IV-PLF310KB

10

H Dimensions
External Dimensions

Model
3G3IV
3G3IV-

Terminal
A
board
PLF310KA TE-K5.5 140
M
PLF320KA M4
PLF310KB

9-26

Dimensions (mm)
B

100

100

D
90

E
70

F
45

Weight
g
(k )
(kg)

7 4.5 dia. 4.5 dia. 0.5