Академический Документы
Профессиональный Документы
Культура Документы
FAS/V3270
FAS/V6210
FAS/V3250
FAS/V3240
FAS/V3210
FAS/V3220
HA
1
1
c0a
0a
0c
e0a
0b
LNK
0a
c0b
0d
c0a
0c
e0a
c0b
0d
e0b
c0a
0c
e0a
c0b
0d
e0b
c0a
0c
e0a
c0b
0d
e0b
c0a
0c
e0a
c0b
0d
e0b
0b
LNK
LNK
LNK
e0b
0a
0b
LNK
LNK
1
c0a
0a
0c
e0a
0b
LNK
LNK
0a
c0b
0d
0b
LNK
LNK
e0b
0a
LNK
0b
LNK
FAS/V3250
0a
LNK
c0a
0c
e0a
c0b
0d
e0b
0b
LNK
Not Supported
1
c0a
0a
0c
e0a
0b
LNK
LNK
c0b
0d
e0b
c0a
0c
e0a
0a
0b
LNK
c0b
0d
e0b
0c
e0a
c0b
0d
e0b
c0a
0c
e0a
c0b
0d
e0b
2
LNK
0a
LNK
c0a
0b
LNK
0a
LNK
0b
LNK
USB
(disabled)
c0b c0a
Serial
Console
Port
Slot 1
Slot 2
1
c0a
0a
LNK
0c
e0a
0b
LNK
c0b
0d
e0b
e0a e0b
0a 0b
SAS
ACP
Management (e0M/SP)
0c 0d
Fibre
Chanel
Ethernet
e0a and e0b ports are GbE
Management and ACP ports are 10/100
Slot
Numbers
160000
Throughput (IOPs)
140000
120000
100900
100000
82800
80000
60000
40000
66600
55600
36300
20000
0
FAS3210
FAS3220
FAS3240
FAS3250
FAS3270
FAS6210
Throughput (IOPs)
86000
61200
52700
44200
38700
28800
FAS3210
FAS3220
FAS3240
FAS3250
FAS3270
FAS6210
3220
3240
3250
3270
6210
A only
A or AE
A or AE
AE only
A or AE
16
16
Physical memory
10GB
24GB
16GB
40GB
40GB
48GB
NVMEM * / NVRAM
1GB
3.2GB
2GB
4GB
4GB
8GB
240
480
600
720
960
1440
Max capacity
720TB
1440TB
1800TB
2160TB
2880TB
4320
Onboard GbE
Onboard 10GbE
4 x 4Gb
4 x 4Gb
4 x 4Gb
4 x 4Gb
4 x 4Gb
8 or 16 8Gb
0 or 8
PCIe slots
4 or 12
4 or 12
12
12
Limited**
HA configurations
CPU cores
Onboard FC / speed
Flash Limits
Platform
Flash Cache
per Controller
Flash Cache
per HA Pair
Flash Pool
per Controller
Flash Pool
per HA Pair
Combined
per Controller
Combined
per HA Pair
FAS/V6210
1.5TB
3.0TB
2.0TB
4.0TB
1.5TB
3.0TB
FAS/V3270
1.0TB
2.0TB
1.0TB
2.0TB
1.0TB
2.0TB
FAS/V3250
1.0TB
2.0TB
1.0TB
2.0TB
1.0TB
2.0TB
FAS/V3240
0.5TB
1.0TB
0.6TB
1.2TB
0.6TB *
1.2TB *
FAS/V3220
0.5TB
1.0TB
0.6TB
1.2TB
0.6TB
1.2TB
FAS/V3210
256GB **
512GB **
Not
supported
Not
supported
Not
supported
Not
supported
* When using both Flash Cache and Flash Pool on a FAS/V3240, the only option for Flash Cache is to
use a 256GB Flash Cache card and either 100MB (1 x SSD data drive) or 200MB (2 x SSD data drives)
per controller. Regardless of the combination selected, both controllers in the HA pair must have the
exact same configuration deployed (symmetrical configuration required).
2) Support for Flash Cache in the FAS/V3210 is limited to existing customers only (no new installations)
running Data ONTAP 8.0.x and Data ONTAP 8.1.1+ (no Data ONTAP 8.1 support).
500
75TB
90TB
90TB
105TB
105TB
162TB
50TB
60TB
50TB
70TB
70TB
70TB
50TB
60TB
50TB
70TB
70TB
70TB
Volume
SnapMirror
Synchronous
SnapMirror
Source/Destination
Source/Destination
FAS/V3210
50/100
FAS/V3220
FAS/V3240
FAS/V3250
FAS/V3270
FAS/V6210
QSM
SnapVault
Source/Destination
Source/Destination
16/16
120/120
120/120
50/100
16/16
320/320
320/320
150/300
32/32
512/512
512/512
IOM6
DS4243
IOM3
DS4246
IOM6
DS4486
IOM6
DS14mk4 *
ESH4
DS14mk2 *
ESH2/ESH4 **
DS14mk2-AT
AT-FCX
* Data ONTAP 8.1.x supports 15K FC disks that are 144GB in size and larger, 10K FC disks
that are 300GB in size and larger, and SATA disks that are 500GB and larger. FC disks 72GB
and smaller are not supported in Data ONTAP 8.1.x.
** DS14mk2 shelves are only supported in Data ONTAP 8.1.x with ESH4 shelf modules.
SSD Support
Standalone and
Active-Active
Data ONTAP
8.0.1
Maximum SSDs
Data ONTAP
8.1.1 / 8.1.2
Maximum SSDs
FAS/V3210
---
96
240
FAS/V3220
---
---
240
FAS/V3240
96
96
240
FAS/V3250
---
---
240
FAS/V3270
96
96
240
FAS/V6210
96
96
240
FAS/V3200 Software
Simple Software Structure
FlexClone
SnapManager suite
E-Series Update
Dedicated Infrastructure
Application-specific or workload-specific
Data ONTAP 8:
E-Series:
Performance-optimized
for dedicated workloads
Sell E-Series
Central IT Workloads
Tier 1 & 2 business applications
Dedicated workloads
HPC: simulation, modeling, research
Engineering applications
Web & IT infrastructure
4GB of cache
Up to 4,000 sustained MB/s*
*Maximum raw performance. Actual performance will vary based on configuration, application and workload.
E5400 Models
E5460
4U/60 drives
E5424
2U/24 drives
Maximum bandwidth
Max density (45TB/RU)
Great performance/watt
Great bandwidth/RU
3.5 7.2K
E5412
2U/12 drives
Industry-leading density
Five 12-drive drawers
Superior RAS
DE5600
2U/24 drives
DE1600
2U/12 drives
Supports high
performance 15K and
high capacity 7.2K SAS
E5424
DE5600
E5412
DE1600
E5400 Controller
USB
Dual Ethernet
connections
Optional host
interface card
DS5300 Shown
4U/60: Overview
Lowers power, cooling, and space requirements
High-density disk shelf supports 60 SAS drives
Just 4U in height and fits standard 19 rack
60% reduction in rack space (compared to 2U/12)
Superior RASUI
Controller drawer movement
Online drive replacement
Safer serviceability
E5400 controllers
Modular Scalability
Scale bandwidth and capacity by adding systems
Scale only capacity by adding disk shelves
FC
InfiniBand
6,000
6,000
3,600
3,600
150K
140K
30K
30K
E5460/7.2K (60)
E5424/10K (24)
E5412/15K (12)
5,800
3,100
2,400
3,600
2,600
2,000
Sell E-Series
Any business
application such
as MS SQL, Oracle,
SAP, IBM DB2, etc.
Any virtualized
environment using
VMware, Hyper-V,
Citrix XenServer,
RHEV or KVM