Think

Inverter.
Think Daikin.
Inverter ACs from World's No. 1 Air-conditioning Company

driving our
green crusade
The most balanced next-generation
refrigerant

What sets
Daikin apart?
D

aikin is committed to delivering


air-conditioning solutions that enhance
the quality of life all around the world
through application of advanced technology.
A comprehensive range of air-conditioners
with inverter technology that provide comfort
throughout the year is a testament to that. Not
only is our technology shaped by the vision of an
unheralded future but our designs are also carved
to optimise form and function.
In all this, the ability to think and act for the
environment continuously sets us apart. Use
of R-32, the next generation refrigerant, in our
product line-up is one such effort.
Spurring our endeavour to provide comfortable
yet meaningful air-conditioning solutions is a
line-up of superior technology, environmentfriendly products. Browse through our brochure
and discover comfortable yet meaningful airconditioning solutions for your daily comfort.

f txR

Series

Heat Pump

Humidification,
Dehumidification,
Purification &
Ventilation

Comfort
sleep
operation

Inverter
powerful
operation

Available in 0.75, 1.2, 1.5 ton


WALL MOUNTED TYPE (HEAT PUMP) FTXR SERIES
Model Name
Capacity
Power Supply
Running Current
(220-230-240V, 50Hz)
Power
Consumption
COP

Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating

Indoor Unit
Outdoor Unit
Rated (Min - Max)
Rated (Min - Max)
Rated
Rated
(Min - Max)
Rated

Kw
Kw

FTXR28KVMA
RXR28KVMA
2.77 (1.55~3.60)
3.57 (1.30~5.00)

A
A
W
W
W/W
W/W

3.3-3.2-3.1
4.0-3.9-3.8
570 (250~800)
710 (220~1410)
4.86
5.03

Indoor Unit
Front Panel Colour
Airflow rate
Fan Speed
Sound Levels
(H/M/L/SL)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
(H/SL)
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference

FTXR28KVMA
Cooling
Heating
Cooling
Heating

m/min
cfm
m/min
cfm

11.1
392
12.4
438

dB (A)

39 / 33 / 26 / 23
41 / 35 / 28 / 25

mm
kg
RXR28KVMA
Type
Cooling
Heating

Cooling
Heating

dB (A)
mm
kg
CDB
CWB
m

46/-46/--

FTXR42KVMA
RXR42KVMA
4.20 (1.55~4.60)
5.08 (1.30~5.60)
1 phase, 220-240V, 50Hz
5.4-5.3-5.2
5.9-5.7-5.6
1070 (260~1320)
1170 (220~1600)
3.93
4.34
FTXR42KVMA
White
12.4
438
12.9
455
5 steps, quiet and Automatic
42 / 35 / 27 / 24
42 / 36 / 29 / 26
305 x 890 x 209
14
RXR42KVMA
Ivory White
Hermetically sealed swing type
48/-48/-693 x 795 x 285
48
10C to 43C
-20C to 18C (Humidify -10 to 24)
10
8

FTXR50KVMA
RXR50KVMA
4.88 (1.55~5.50)
5.91 (1.30~6.20)
7.2-7.1-7.0
7.3-7.2-7.1
1470 (260~1800)
1490 (230~1770)
3.32
3.97
FTXR50KVMA
13.3
470
14
494
44 / 37 / 29 / 26
44 / 38 / 31 / 28

RXR50KVMA

48/-50/--

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation
as a result of ambient conditions.

f txg Series

Heat Pump

Comfortable
mode

Hot start

Intelligent
eye

Available in 0.75, 1.0, 1.4 ton


WALL MOUNTED TYPE (HEAT PUMP) FTXG SERIES
Model Name
Capacity
Power Supply
Running Current
(220-230-240V, 50Hz)
Power Consumption
COP

Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating

Indoor Unit
Outdoor Unit
Rated (Min - Max)
Rated (Min - Max)
Rated
Rated
(Min - Max)
Rated

Kw
Kw

FTXG25JV1BA
RXG25K3V1B
2.5 (1.3~3.0)
3.4 (1.3~4.5)

A
A
W
W
W/W
W/W

3.2-3.0-2.9
4.4-4.2-4.1
560 (350 - 820)
780 (320 - 1320)
4.46
4.36

Indoor Unit
Front Panel Colour

FTXG25JV1BA
Cooling

Airflow rate
Heating
Fan Speed
Sound Levels
(H/M/L/SL)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels (H/SL)

Cooling
Heating

Max. Piping Length


Max. Height Difference

8.8
311
9.6
339

dB (A)

38 / 32 / 25 /22
39 / 34 / 28 / 25

mm
kg
RXG25K3V1B
Type
Cooling
Heating

Dimensions (HxWxD)
Machine Weight
Operation range

m/min
cfm
m/min
cfm

Cooling
Heating

dB (A)
mm
kg
CDB
CWB
m

46/43
47/44

FTXG35JV1BA
RXG35K3V1B
3.5 (1.4~3.8)
4.0 (1.4~5.0)
1phase, 220-240V, 50Hz
5.1-4.8-4.6
5.6-5.3-5.1
890 (360 - 1220)
990 (320 - 1500)
3.93
4.04
FTXG35JV1BA
Silver
10.1
357
10.8
389
5 steps, quiet and Automatic
42 / 34 / 26 / 23
42 / 36 / 29 / 26
295 x 915 x 155
11

RXG35K3V1B
Ivory White
Hermetically sealed swing type
48/44
48/45
550 x 765 x 285
34
-10C to 46C
-15C to 20C
20
15

FTXG50JV1BA
RXG50K3V1B
5.0 (1.7~5.3)
5.8 (1.7~6.5)
7.2-6.9-6.6
7.4-7.1-6.8
1560 (450 - 1880)
1600 (520 - 2500)
3.21
3.63
FTXG50JV1BA
10.3
364
11.4
402
44 / 40 / 35 / 32
44 / 40 / 35 / 32

RXG50K3V1B

735 x 825 x 300


48

30
20

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation
as a result of ambient conditions.

f txs

Series

Heat Pump

3D airflow

mould proof
operation

power
airflow dual
flaps

Available in 0.75, 1.0, 1.5, 1.8, 2.2 ton


WALL MOUNTED TYPE (HEAT PUMP) FTXS SERIES
Indoor Unit
Outdoor Unit
Cooling
Rated (Min.-Max)
Capacity
Heating
Rated (Min.-Max)
Power Supply
Cooling
Running Current
Rated
Heating
Cooling
Rated
Power consumption
(Min.-Max)
Heating
Cooling
COP
Rated
Heating
Model Name

Indoor Unit
Front panel Colour
Airflow rate (H)

Cooling
Heating

m3/min(cfm)

Cooling
Heating

dB (A)

Fan speed
Sound Levels (H/L/SL)
Dimensions (HxWxD)
Machine weight

mm
Kg

Outdoor Unit
Casing colour
Compressor
Sound Levels (H/SL)

Max. piping length


Max. height difference

A
W
W/W

3.3
4.1
600 (300-800)
830 (290-1,340)
4.17
4.10

FTXS35EVMA
RXS35EBVMA
3.5 (1.2-3.8)
4.0 (1.2-5.0)

FTXS50FVMA
FTXS60FVMA
FTXS71FVMA
RXS50FVMA
RXS60FVMA
RXS71FVMA
5.0 (1.7-6.0)
6.0 (1.7-6.7)
7.1 (2.3-8.5)
5.8 (1.7-7.7)
7.0 (1.7-8.0)
8.2 (2.3-10.0)
1 phase, 230 V, 50Hz
4.7
6.9
8.8
10.4
4.9
7.1
9
11.1
1,020 (300-1,200) 1,550 (440-2,080) 1,980 (440-2,390) 2,360 (570-3,200)
1,080 (290-1,550) 1,600 (400-2,530) 2,040 (400-2,810) 2,520 (520-3,730)
3.43
3.23
3.03
3.01
3.70
3.63
3.43
3.25

FTXS25EVMA

FTXS35EVMA

FTXS50FVMA
FTXS60FVMA
FTXS71FVMA
White
8.7 (307)
8.9 (314)
14.7(519)
16.2(572)
17.4(614)
9.4 (332)
9.7 (342)
16.2 (572)
17.4 (614)
21.5 (759)
5 steps, quiet and automatic
37 / 25 / 22
38 / 26 / 23
44 / 35 / 32
45 / 36 / 33
46 / 37 / 34
37 / 28 / 25
38 / 29 / 26
42 / 33 / 30
44 / 35 / 32
46 / 37 / 34
283 x 800 x 195
290 x 1,050 x 238
9
12

RXS25EBVMA

RXS35EBVMA

Type
Cooling
Heating

dB (A)

Cooling
Heating

mm
Kg
CDB
CWB
m
m

Dimensions (HxWxD)
Machine weight
Operation Range

Kw
Kw

FTXS25EVMA
RXS25EBVMA
2.5 (1.2-3.0)
3.4 (1.2-4.5)

46 / 43
47 / 44
550 x 765 x 285
34
-15 to 20
20
15

RXS50FVMA
RXS60FVMA
Ivory White
Hermetically sealed swing type
47 / 44
49 / 46
48 / 45
49 / 46

735 x 825 x 300
48
10 to 46
-15 to 18
30
20

RXS71FVMA

52 / 49
52 / 49
770 x 900 x 320
71

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp.7 CDB, 6 CWB; piping length 7.5m.
3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation
as a result of ambient conditions.

ftKm Series

Coanda
airflow

Silver partical
anti-bacterial
filter

Stabilizer free

Available in 0.75, 1.0, 1.5, 1.8, 2.2 ton


WALL MOUNTED TYPE (COOLING ONLY) FTKM SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Rated (Min - Max)
Kw
Power Supply
Running Current
Rated
A
Power Consumption
Rated (Min - Max)
W
COP
Rated (Min - Max)
W/W
Indoor Unit
Front Panel Colour
m/min
cfm

Airflow rate (H)


Fan Speed
Sound Levels (H/M/L/SL)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels (H/SL)
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference

dB (A)
mm
kg

FTKM25PRV16
RKM25PRV16
2.5 (1.0~3.2)

FTKM35PRV16
RKM35PRV16
3.5 (1.0~4.0)

3.07
650 (220~900)
3.85(4.55~3.55)

4.55
964 (220~1300)
3.63 (4.55~3.08)

FTKM25PRV16

FTKM35PRV16

FTKM60PRV16
RKM60PRV16
6.0 (1.0~7.0)

FTKM71PRV16
RKM71PV16
7.1 (2.1~8.0)

7.40
1666(230~2250)
3.60(4.35~3.11)

9.60
2220 (530~3300)
3.20 (3.96~2.42)

FTKM50PRV16
FTKM60PRV16
White
9.6
9.7
17.4
18.1
338
342
614
639
5 steps, quiet and Automatic
37 / 33 / 28 / 25
39 / 34 / 29 / 26
42 / 38 / 35 / 29
45 / 41 / 35 / 31
283 x 800 x 198
310 x 1100 x 239
8
13
RKM25PRV16

RKM35PRV16

Type
dB (A)
mm
kg
CDB
m
m

FTKM50PRV16
RKM50PRV16
5.0 (1.0~6.0)
1 phase, 230V, 50Hz
5.80
1315(230~1700)
3.80(4.35~3.52)

47 / 43
48 / 44
550 x 765 x 285
33
20
15

RKM50PRV16
RKM60PRV16
Ivory White
Hermetically sealed swing type
47 / 44
49 / 46
595 x 845 x 300
39
10C to 46C
30
20

FTKM71PRV16
20.4
720
46 / 42 / 36 /32

RKM71PV16

52 / 49
735 x 825 x 300
49

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a
result of ambient conditions.

f tKP

Series

Coanda
airflow

indoor
unit quiet
operation

Stabilizer free

Available in 0.75, 1.0, 1.5, 1.8 ton


WALL MOUNTED TYPE (COOLING ONLY) FTKP SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Rated (Min - Max)
Power Supply
Running Current
Rated
Power Consumption
Rated (Min - Max)
COP
Rated (Min-Max)

Kw

FTKP25PRV16
RKP25PRV16
2.5 (2.0~3.2)

A
W
W/W

3.49
723(480~900)
3.46(4.17~3.55)

Indoor Unit
Front Panel Colour

FTKP25PRV16

FTKP35PRV16

FTKP50PRV16

FTKP60PRV16
RKP60PRV16
6.0 (2.5~6.7)
7.80
1765 (720~2220)
3.40(3.47~3.02)
FTKP60PRV16

White
m/min
cfm

Airflow rate (Power Chill)


Fan Speed
Sound Levels (H/M/L)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference

FTKP35PRV16
FTKP50PRV16
RKP35PRV16
RKP50PRV16
3.4 (2.0~4.0)
5.0 (2.5~5.7)
1 phase, 230V, 50Hz
4.74
6.50
982(480~1310)
1445(710~1750)
3.46(4.17~3.05)
3.46(3.52~3.26)

dB (A)
mm
kg

9.6
338

9.9
17.4
18.1
349
614
639
5 steps, quiet and Automatic
37 / 33 / 28
40 / 36 / 31
45 / 40 / 35
47 / 43 / 38
283 x 800 x 198
310 x 1100 x 239
8
13
RKP25PRV16

Type
dB (A)
mm
kg
CDB
m

RKP35PRV16

RKP50PRV16
RKP60PRV16
Ivory White
Hermetically sealed swing type
49
50
54
550 x 765 x 285
595 x 845 x 300
33
41
40
19.4C to 46C
15
15
15
20

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a
result of ambient conditions.

ftF-P Series

power chill
operation

Titanium appatite econo mode


photocatalytic
aiR purifying
filter

Available in 1.0, 1.5, 1.8* ton


WALL MOUNTED TYPE (COOLING ONLY) FTF - P SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Kw
Power Supply
Running Current
A
Power Consumption
W
COP
W/W
Indoor Unit
Front Panel Colour
Airflow rate (H)
Fan Speed
Sound Levels (H/M/L)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference

FTF35PRV16
RF35PRV16
3.35
4.30
931
3.60
FTF35PRV16

m/min
cfm

9.7
342

dB (A)
mm
kg

39 / 35 / 29
283 x 800 x 205
8
RF35PRV16

Type
dB (A)
mm
kg
CDB
m

FTF50PRV16
RF50PRV16
5.2
1 phase, 230V, 50Hz
6.60
1,444

49
550 x 765 x 285
37

15

FTF60PRV16*
RF60PRV16*
6.4
8.60
1,882
3.40

FTF50PRV16
FTF60PRV16
White
18.1
20.4
639
720
3 steps and Automatic
44 / 41 / 35
47 / 41 / 35
310 x 1100 x 258
13
RF50PRV16
Ivory White
Hermetically Sealed Rotary Type
50
595 x 845 x 300
41
19.4C to 46C
20
10

RF60PRV16

56
43

*Available in 4 star
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as
a result of ambient conditions.

ftC-P Series

programme
dry function

good sleep
off timer

self diagnosis
digital display
remote

Available in 1.0, 1.5, 1.8 ton


WALL MOUNTED TYPE (COOLING ONLY) FTC-P SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Kw
Power Supply
Running Current
A
Power Consumption
W
COP
W/W
Indoor Unit
Front Panel Colour
Airflow rate (H)
Fan Speed
Sound Levels (H/M/L)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference

FTC35PRV16
RC35PRV16
3.35
4.60
1,030

FTC35PRV16
m/min
cfm

9.7
342

dB (A)
mm
kg

39 / 35 / 29
283 x 800 x 205
8
RC35PRV16

Type
dB (A)
mm
kg
CDB
m

51
550 x 765 x 285
33

15

FTC50PRV16
RC50PRV16
5.22
1 phase, 230V, 50Hz
7.31
1,605
3.25

FTC60PRV16
RC60PRV16
6.40
8.97
1,970

FTC50PRV16
FTC60PRV16
White
18.1
20.4
639
720
3 steps and Automatic
44 / 41 / 35
47 / 41 / 35
310 x 1100 x 258
13
RC50PRV16
RC60PRV16
Ivory White
Hermetically Sealed Rotary Type
54
56
595 x 845 x 300
39
40
19.4C to 46C
20
10

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result
of ambient conditions.

ftQ-P Series

smell proof
operation

good sleep
off timer

auto restart
(after power
failure)

Available in 1.0, 1.5, 1.8 ton


WALL MOUNTED TYPE (COOLING ONLY) FTQ-P SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Kw
Power Supply
Running Current
A
Power Consumption
W
COP
W/W
Indoor Unit
Front Panel Colour
Airflow rate (H)
Fan Speed
Sound Levels (H/M/L)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference

FTQ35PRV16
RQ35PRV16
3.35
4.90
1,098

FTQ35PRV16
m/min
cfm

9.7
342

dB (A)
mm
kg

39 / 35 / 30
283 x 800 x 205
8
RQ35PRV16

Type
dB (A)
mm
kg
CDB
m

51
550 x 765 x 285
33

15

FTQ50PRV16
RQ50PRV16
5.20
1 phase, 230V, 50Hz
7.76
1,705
3.05

FTQ60PRV16
RQ60PRV16
6.40
9.56
2,099

FTQ50PRV16
FTQ60PRV16
White
18.5
20.4
653
720
3 steps and Automatic
45 / 41 / 35
47 / 41 / 35
310 x 1,100 x 258
13
RQ50PRV16
Ivory White
Hermetically Sealed Rotary Type
54
595 x 845 x 300
36
19.4C to 46C
20
10

RQ60PRV16

56
40

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result
of ambient conditions.

f tyn

Series

Heat Pump

vertical auto
swing

Saranet filter

PE Anticorrosion
treatment of
outdoor heat
exchanger

Available in 1.0, 1.5, 1.8 ton


WALL MOUNTED TYPE (HEAT PUMP) FTYN SERIES
Indoor Unit
Outdoor Unit
Cooling
Kw
Capacity
Heating
Kw
Power Supply
Cooling
A
Running Current
Heating
A
Cooling
W
Power Consumption
Heating
W
Cooling
W/W
COP
Heating
W/W
Model Name

Indoor Unit
Front Panel Colour
Airflow rate (T/H/M/L/Q)
Fan Speed
Sound Levels (T/H/M/L/Q)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference

FTYN35JXV1
RYN35CJXV1
3.15
3.38
5.10
4.70
1,094
988
2.88
3.42
FTYN35JXV1

Cooling
Cooling

m/min
cfm

10.5 / 10.1 / 8.4 / 6.9 / 6.4


372 / 355 / 298 / 242 / 225

dB (A)
mm
kg

41 / 40 / 35 / 29 / 28
288 x 800 x 206
9
RYN35CJXV1

Type
Cooling

Cooling
Heating

mm
kg
CDB
CWB

dB (A)
540 x 700 x 250
31

1. Cooling: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB


2. Heating: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB
3. All units are being tested and comply to ISO 5151 (Non-ducted unit).

12
5

FTYN50JXV1
RYN50CJXV1
5.25
5.28
1 phase, 220-240V, 50Hz
7.19
6.53
1,635
1,490

FTYN60JXV1
RYN60CJXV1
6.01
6.15
8.26
7.99
1,870
1,800
3.21

3.54

3.42

FTYN50JXV1
FTYN60JXV1
White
16.1 / 15.2 / 13.5 / 12.0 / 10.6 18.2 / 17.4 / 15.2 / 13.4 / 11.8
570 / 536 / 478 / 424 / 375
641 / 614 / 537 / 474 / 418
3 steps, Turbo and Quiet
44 / 42 / 39 / 36 / 34
48 / 46 / 43 / 40 / 37
310 x 1065 x 224
14
RYN50CJXV1
Light Grey
Rotary
49
651 x 855 x 328
47
19C to 46C
-9C to 18C

RYN60CJXV1

52
753 x 855 x 328
50

20
15

Ten Reasons to
Buy Daikin
Air-conditioning
Specialist
Daikin focuses on
air-conditioning solutions
and control systems. As
specialists, its all we
do. No wonder Daikin is
recognised as an expert in
air-conditioning.

Pioneer in
Air-conditioners
Daikin has been providing
air-conditioning solutions
for over 12 years in India.
As one of the industrys
more trusted names, Daikin
air-conditioning equipment
can be found in homes,
offices, hotels and shops.
Daikin is committed to the
air-conditioning market and
has a manufacturing facility
located in Rajasthan.

The Daikin Edge


with in-house
Manufacturing
Daikin is the only company
in the world dedicated
to manufacturing both
air-conditioning systems
and refrigerants. Each
element has been designed
to work flawlessly with the
next - delivering optimal
performance - from the
time a project begins till
the moment of absolute
comfort.

Unmatched
After-sales Support

Year Warranty
on Compressors

Wise Investment
Low Running Cost

Daikin takes pride in


providing its customers with
efficient after sales support,
including readily available
spare parts warehoused in
India.

Reliability. Thats probably


top of your list when buying
an air-conditioning system
for your home or business.

When you buy a Daikin


air-conditioning system you
need to look beyond the
initial purchase price. It pays
to consider ongoing running
costs in conjunction with the
potential life of the product.
Daikin systems offer superior
build quality and energy
efficiency.

Daikin gives you peace of


mind and reassurance with
their 5-year warranty on
compressors of Split ACs.
Thats how confident Daikin
is about the quality and
reliability of its product.

High Energy
Efficiency

Comprehensive
Range & Quiet
Operation

Daikins continuous drive


for improved efficiency has
seen its advanced inverter
technology being applied
to split, ducted and other
systems. These systems
provide a more comfortable
environment and are more
energy efficient when
compared to non-inverter
systems.

Daikin has a comprehensive


range of products in both
domestic and commercial
segments. Designed to
provide effective and quiet
air-conditioning, Daikin can
customise a solution to meet
every requirement.

Experienced
Dealers
Daikin distributes
its products through
experienced dealers. This
ensures that you receive
a top quality product with
expert support. Together
this means the best
air-conditioning solution for
your individual needs.

Environment
Friendly
Daikin continues to work
towards a sustainable
future and has received
Environmental Management
System certification to
ISO14001. Daikin
Air-conditioning India
Pvt. Ltd. is dedicated to
preserving and protecting
the environment through
the production of energy
efficient products.
Terms & Conditions Apply

Humidity control Technology

Function

FTXR

FTXG

FTXR28/42/50KVMA

FTXG25/35/50JV1BA

FTXS25/35EVMA

FTXS
FTXS50/60/71FVMA

FTKM25/35PRV16

FTKM

RXR28/42/50KVMA

RXG25/35/50K3V1B

RXS25/35EBVMA

RXS50/60/71FVMA

RKM25/35PRV16

Swing Compressor & Reluctance DC Motor


Rotary Compressor
PAM Control
Humidifying Operation
Drying Operation
Dry Cooling Operation
Moisturising Operation
Cooling Breeze Operation
Comfortable Mode

Comfortable Airflow

Power-airflow Flap
Power-airflow Dual Flaps
Wide-angle Louvers
Vertical Auto-swing (up and down)
Horizontal Auto-swing (left and right)
3-D Airflow
Comfort Sleep Operation
Hot Start
Coanda Airflow Mode
Comfort Control

Indoor Unit Quiet Operation


Outdoor Unit Quiet Operation
Intelligent Eye
Automatic Operation (Heating and Cooling)
Programme Dry Function
Auto Fan Speed
Temperature & Humidity Level Information Display
ECONO Mode
Lifestyle Convenience

Home Leave Operation


Inverter Powerful Operation
New Powerful Operation (Non-Inverter)
POWER CHILL Operation
Indoor Unit ON/OFF Switch
Child Lock
Multi-coloured Indicator
Monitor Brightness Setting
Fan Only
Filter Cleaning Indicator
Mould Shock Operation
Home Leave Ventilation
Streamer Discharge Air Purifier
Mould-Proof Operation
Cleanliness

Mould Proof Stick


Smell-Proof Operation
Titanium Apatite Photocatalytic Air-Purifying Filter

Option

Air Purifying Operation


Air Supply Filter
Silver Particle Anti-Bacterial Filter
Saranet Filter
Air-purify Filter with Photocatalytic Deodorising Function
Fresh Air Supply Ventilation
Wipe-clean Flat Panel

Timers

24-Hour ON/OFF Timer


Count Up-down ON/OFF Timer
Night Set Mode

Worry Free

Good Sleep Off Timer


Auto-restart (after power failure)
Stabilizer Free
Self-diagnosis (R/C, LED) Display
PE Anti-corrosion Treatment of Outdoor Heat Exchanger
R/C with Back Light
Control

*1

Weekly Timer

Luminescent R/C Button


Indoor temp. Display on R/C
R/C LCD Back Light OFF

*1-Off only, *2-Special Button on remote control

*2

FTKM

RKM50

FTKM

PRV16

FTKM50/60/71PRV16

PRV16

RKM50/60PRV16, RKM71PV16

FTKP

5 star

FTKP25/35PRV16 FTKP50/60PRV16

FTF35/50/60PRV16

FTC35PRV16

FTC50/60PRV16

FTQ35PRV16

FTQ50/60PRV16

FTYN35/50/60JXV1

RKP25/35PRV16

RF35/50/60PRV16

RC35PRV16

RC50/60PRV16

RQ35PRV16

RQ50/60PRV16

RYN35/50/60CJXV1

Option

Option

Option

Option

Option

Option

Option

Option

RKP50/60PRV16

Option

Option

*2

*2

Option

*2

Option

Option

3 star

2 star

FTYN

12th Floor, Building No. 9, Tower A, DLF Cyber City, DLF Phase III, Gurgaon - 122 002, Haryana, India.
Tel.: 0124-4555444, Fax.: 0124-4555333, e-mail: ho@daikinindia.com

Follow us on:

www.facebook.com/daikinindia

Jaipur: 0141-2223215, 2225569


Kolkata: 033-22894259/60
Lucknow: 0522-2787307/340/291
Mumbai: 022-30926666
Pune: 020-25560300

www.twitter.com/daikinindia

Service toll free


1800-102-9300, 1800-22-9300
cs@daikinindia.com

Visit us at www.daikinindia.com

www.daikinindiablog.com

As a continuing policy of product innovation at Daikin, the design and specifications are subject to change without prior notice. The visuals of the products in the catalogue are representative only, actual
products might differ from the ones shown.
Sales revenue includes revenue through sales of all Daikin Air-conditioning Systems. Worlds no.1 position based on internal assessment of total sales revenue for 2012/13.
Worlds no.1 position based on internal assessment of total company sales revenue for 2012/13.
Products mentioned in this catalogue comply with RoHS regulations as per E-waste (Management & Handling) Rules, 2011 and should not be mixed with general household waste at the end of their
useful life. For more details kindly visit our website www.daikinindia.com or contact our customer care centre at 1800 102 9300 / 1800 22 9300.

DAIPL-2014/14-RA20-2A

Ahmedabad: 079-26583013/14, 36583364


Bengaluru: 080-25590452-54
Chandigarh: 0172-5089862-64
Chennai: 044-24314210-15
Delhi-NCR: 011-26385924-27
Hyderabad: 040-39134289/93

Вам также может понравиться