VLT 6000 Series Drives for HVAC

VLT 6000 Series drives are specially


designed for the unique requirements
of HVAC applications. Rich in standard
features, including PID control, energy
optimizing capabilities, and DC-link
reactors, the VLT 6000 Series provides low
motor noise with high eciency. With a
broad range of pre-engineered bypass
panel congurations and controls available,
the VLT 6000 Series is the ideal solution for
a variety of HVAC applications.

Customized Setup
All drives ship with customers application
pre-programmed. After input of motor
nameplate data, drive is ready for service.

Easy-to-Use Keypad
Keypads are interchangeable, allowing
parameters from one drive to be
downloaded to others. Remote keypad
mounting is also available.
User can see at a glance any four
of twenty-ve possible displays
simultaneously, such as drive frequency,
current, output kW, and output kW-h
Display can show process variables, such
as %, F, C, Pa, bar, RPM, in. wg., gal/s, gal/
min, gal/hr, ft3/sec, ft3/min, ft3/hr, or lb/in2

Monitoring Functions
Missing motor phase
Output ground fault
Loss of control signal
Loss of load or broken belt
Output short circuit
Low or missing input phase
Motor overload using internal electronic
I2t overload
Line and DC bus undervoltage and
overvoltage; output overcurrent

Performance Ranges

Communications

208 V: 1 to 60 HP
460 V: 1 to 600 HP
600 V: 1 to 400 HP

EIA-485 Interface
Fully equipped for serial communication,
up to 31 drives can be connected to one
serial bus up to 5,000 feet long.

Enclosures
Drive and option enclosures available in
NEMA 1, NEMA 3R and NEMA 12

Depth of Features
Built-in Two Setpoint PID Controller
eliminates the need for a separate
setpoint or PID controller.
Automatic Energy Optimization (AEO)
constantly adjusts the motor voltage
to optimize energy savings even under
changing speed and load conditions.
Automatic Motor Adaptation (AMA)
optimizes performance and eciency by
measuring the motors stator resistance
and reactance without running the motor
or disconnecting the load.
Automatic Switching Frequency
Modulation (ASFM) provides quiet motor
operation at critical low ow conditions
and full output without derating at high
load.
Exclusive Digital Voltage Vector Control
provides nearly perfect output current
sine wave and full rated motor voltage
at rated frequency, resulting in high
eciency for both drive and motor.
DC-Link Reactor provides harmonics
mitigation equivalent to a 5% AC line
reactor, without the voltage drop and
ineciencies of AC line reactors.
Fireghter's Override Mode can be
invoked automatically by the buildings
automation system, allowing re and
smoke to be controlled, contained and
extracted by utilizing the HVAC system.

Built-in Serial Communications


Johnson Controls Metasys N2, Siemens
Apogee FLN (Floor Level Network),
and Modbus RTU are standard, built-in
protocols. Other serial communications
capabilities are available with the optional
LonWorks communication card and VLT
BACLink portal.
PC Communciation
Available free of charge from the Danfoss
website, the MCT 10 set-up software
provides monitoring capabilities and
control of drive parameters for multiple
drives from a Windows-based PC.

Options
Bypass, Disconnect, Fuses, and Circuit
Breaker option panels are assembled
at the factory's UL panel shop. All drives
and panels are built in ISO 9001 certied
facilities.
Real-Time Clock allows the system to
anticipate conditions or override the
setpoint for a period of time, enhancing
control, comfort and eciency.
Integrated Bypass conguration
economizes space in crowded installations.
EMI, RFI Filters, Input AC Line Reactors can
supplement the harmonic protection of
built-in DC link reactors.
Cascade Controller Card allows staging of
up to four additional motors or drives.

Drives Solutions

Specications
Input Voltages.......................................................................................................................................................................................200 240; 380 460; 550 600 VAC
Motor Voltages...............................................................................................................................200, 208, 220, 230, 240, 380, 400, 415, 440, 460, 550 or 575 VAC
Input Voltage Range for Full Output.....................................................................................................................................................................................Nominal 10%
Undervoltage Trip Point...................................................................................................................................................................................................164, 313 or 394 VAC
Overvoltage Trip Point......................................................................................................................................................................................................299, 538 or 690 VAC
Input Frequency.....................................................................................................................................................................................................................50 or 60 Hz, 2 Hz
Output Frequency..........................................................................................................................................................................................................Selectable 0 to 120 Hz
Drive Eciency...................................................................................................................................................97% or greater at full load and nominal motor speed
Input Displacement Power Factor.............................................................................................................................................0.98 or greater at all speeds and loads
Follower Signal..........................................................................0 to 5 V DC, 0 to 10 V DC, 0 to 20 mA, 4 to 20 mA fully selectable, direct and inverse acting
Lost Analog Reference Action...........Selectable to go to a preset speed, go to maximum speed, stay at last speed, stop, turn o, or stop and trip
Time Delay for Lost Analog Reference Action...........................................................................................................................................................................1 to 99 sec.
Output Current Limit Setting.............................................................................................................................................................Adjustable to 110% of drive rating
Current Limit Timer.........................................................................................................................................................................................................0 to 60 sec. or innite
Adjustable Maximum Speed..................................................................................................................................................From minimum speed setting to 120 Hz
Adjustable Minimum Speed.......................................................................................................................................................From maximum speed setting to 0 Hz
Adjustable Acceleration Time..........................................................................................................................................................................To 3,600 sec. to base speed
Adjustable Deceleration Time....................................................................................................................................................................To 3,600 sec. from base speed
Adjustable Auto Restart Time Delay...........................................................................................................................................................................................0 to 600 sec.
Breakaway Torque Time (1.6 times drive rated current)....................................................................................................................................................0.0 to 0.5 sec.
Maximum Number of Preset Speeds..............................................................................................................................................................................................................16
Maximum Number of Frequency Stepovers..................................................................................................................................................................................................4
Maximum Number of Accel/Decel Rates........................................................................................................................................................................................................4
Number of Programmable Digital Inputs.......................................................................................................................................................................................................8
Number of Programmable Analog Inputs....................................................................................................................................................Three: 2 voltage, 1 current
Number of Programmable Analog Outputs.............................................................................................................................................................................................Two
Number of Programmable Relay Outputs.................................................................Two: 1 standard Form A 30 VAC, 1 A; 1 standard Form C 240 VAC, 2 A
(One or four additional optional)
Low Frequency and High Frequency Warnings........................................................................................................................................................................0 to 120 Hz
Low Current and High Current Warnings..............................................................................................................................................................0 to maximum current
Start Voltage...............................................................................................................................................................................................................................................0 to 10%
Delayed Start.......................................................................................................................................................................................................................................0 to 120 sec.
DC Braking Time...................................................................................................................................................................................................................................0 to 60 sec.
DC Braking Start.......................................................................................................................................................................................................0 to maximum frequency
DC Braking Current.....................................................................................................................................................................................0 to 50% of rated motor current
Automatic Restart Attempts................................................................................................................................................................................................0 to 20 or innite
Automatic Restart Time Delay........................................................................................................................................................0 to 600 sec. between each attempt
Relay ON Delay and Relay OFF Delay (for the standard Form C relay and 4 relay option)......................................................................................0 to 600 sec.
Display Languages..........................................................................................English, Spanish, French, German, Italian, Portuguese, Swedish, Dutch, Danish
Ambient Operating Temperature Range...................................................................................................................................................14F to 104F (-10C to 40C)
Humidity.........................................................................................................................................................................................................................<95%, non-condensing
Maximum Elevation without Derate................................................................................................................................................................................3,300 ft. (1000 m)

North America Motion Controls

www.namc.danfoss.com

Danfoss can accept no responsibility for possible errors in catalogs, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also
applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in
this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss Graham
Division of Danfoss Inc.
8800 W. Bradley Rd.
Milwaukee, WI 53224, USA
Phone: 1.800.621.8806
1.414.355.8800
Fax:
1.414.355.6117
Copyright 2005 by Danfoss Inc. 5/05

rev. NAMC.PB.B1.22

175R5326

Вам также может понравиться