Вы находитесь на странице: 1из 24

FCAT 1000-N

Installation and User Guide

Copyrights

This manual and the information contained herein is proprietary information and is intended for the exclusive use of MRO-TEK customers. The
information in this manual should not be copied, distributed, shared or reproduced in any manner without the express written permission of
MRO-TEK. Information contained in this document is subject to change. In the event of a change, this document will be revised.
Restrictions
The software described in this document is the property of MRO-TEK. It is furnished under a license agreement and may be used and/or disclosed
only in accordance with the terms of the agreement. Software and documentation are copyright materials. Making unauthorized copies is prohibited by
law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language
or computer language, in any form or by any means, without prior written permission of MRO-TEK.
Accuracy
While reasonable efforts have been made to assure the accuracy of this document, MRO-TEK assumes no liability resulting from any inaccuracies or
omissions in this document, or from the use of the information obtained herein. MRO-TEK reserves the right to make changes to any products
described herein to improve reliability, function, or design, and reserves the right to revise this document and to make changes from time to time in
content hereof with no obligation to notify any person of revisions or changes. MRO-TEK does not assume any liability arising out of the application
or use of any product or circuit described herein; neither does it convey license under its patent rights of others.
Trademarks
MRO-TEK and the MRO-TEK logo are registered trademarks of MRO-TEK Limited.
All other brands and corporate names are trademarks of their respective owners.

MRO-TEK LTD.
Bellary Road, Hebbal,
Bangalore - 560 024, INDIA
Ph: +91 80 2333 2951
Fax: +91 80 2333 3415
Email: mrotek@vsnl.com
Web: www.mro-tek.com

Version status of this manual


The following shows the issue status of this manual since its release.

Version information
The following lists the versions of this manual in order of manual release:
Table 1 Version information
Manual
version

Date of release e

Remarks

1.0

July 2010

Original Issue 1.0

1.1

December 2010

60Km Optics information update

1.2

October 2012

MROTEK revised logo for 2012

Text conventions
In the manual, new and amended features are tagged to help users to assess the impact. The tags include
index references which are listed in the manual Index.
Table 2: Text convention
ICON

Notice Type

Alerts

NOTE

Important feature or instruction.

Caution

Risk of personal injury, system damage, or loss of data

Warning

Risk of severe personal injury

The tags are positioned in text as follows:

Cross references
Throughout this manual, references are made to external publications, chapter numbers and section names.
The references to external publications are shown in italics, chapter and section name cross references are
emphasized in bold.

2010
All Rights Reserved

Table
of
Contents

Contents
FCAT1000-N

Chapter 1 Overview of FCAT1000-N ......................................................................................................... 1-1


Introduction................................................................................................................................................................. 1-2
Specification ....................................................................................................................................................... 1-2
Fiber Optic Specifications ................................................................................................................................... 1-3
Features.............................................................................................................................................................. 1-3
Physical Description............................................................................................................................................ 1-4

Chapter 2 Installation and Setup.................................................................................................................. 2-1


Installation .................................................................................................................................................................. 2-2
Package Content ................................................................................................................................................ 2-2

Installing FCAT 1000-N ..................................................................................................................................... 2-2


Site Requirement and prerequisites.................................................................................................................... 2-2
Connecting the interfaces ................................................................................................................................... 2-3
Connecting to Power........................................................................................................................................... 2-3
Connecting the Ethernet Interface ...................................................................................................................... 2-3
Connecting the SC Interface............................................................................................................................... 2-4
Application .......................................................................................................................................................... 2-4

Chapter 3 Operation ...................................................................................................................................... 3-1

Operating FCAT 1000-N ........................................................................................................................................... 3-2

Turning on FCAT 1000-N .................................................................................................................................. 3-2


LED Indicators .................................................................................................................................................... 3-2
DIP Switch .......................................................................................................................................................... 3-3
Installation .................................................................................................................................................................. 3-4

Chapter 4 Appendix A ................................................................................................................................... 4-1


Safety Notices ............................................................................................................................................................ 4-2
Safety Precautions.............................................................................................................................................. 4-2
Modifications to Equipment................................................................................................................................. 4-2
Placement of the unit .......................................................................................................................................... 4-2

Chapter 5 Appendix B ................................................................................................................................... 5-1


F.A.Q .......................................................................................................................................................................... 5-2

List of
Figures

List of Figures
Figure 1: FCAT1000-N ................................................................................................................................................... 1-4
Figure 2: Front Panel of FCAT1000-N media converter ................................................................................................. 2-3
Figure 3: Application.......................................................................................................................................................... 2-4
Figure 4: Front Panel LED indicators ................................................................................................................................ 3-2

ii

List of Tables
Table 1 Version information ................................................................................................................................................. 1
Table 2: Text convention ...................................................................................................................................................... 1

1-1

Chapter 1
Overview of FCAT1000-N

1-1


FCAT 1000-N

Introduction

Introduction
The FCAT1000-N is a single channel stand-alone Media converters provide media conversion from
1000Base-TX to 1000 Base-FX on multimode or single mode fiber up to 60kms. Available in Stand-alone,
internal auto ranging AC/DC Power supplies and a versatile range of Fiber Optic interfaces, FCAT1000N becomes a complete offering to suit Carriers, Service Providers and Enterprises for wide range of
deployments.
It is an Unmanaged Gigabit Ethernet Media converter, which supports a variety of advanced features and
flexible interface options, giving service providers the power to quickly and profitably deploy Ethernet
services. Enterprise customers can leverage existing Gigabit Ethernet infrastructure for long haul connects.
FCAT1000-N is a rugged and reliable Gigabit Ethernet media converter providing seamless extension of
Gigabit Ethernet on single mode/multi mode fiber up to 60 kms. It is very flexible and it adapts to
different connectivity needs make this product an essential component of any network design.

Specification
Standards Compliance

IEEE 802.3ab, IEEE 802.3z


1000BASE-TX, 1000BASE-FX

1000BASE-TX port:

Shielded RJ-45

Duplex support

Half/Full

Auto MDI-I / MDI-X

1000Base-FX port

SC connector

LED Indicators
PWR (green)

Power status

Link(LNK)

Link Status for Ethernet ports

Activity (ACT)

Activity status for Ethernet ports

LFP

Link Fault Propagation Indication for Ethernet ports

FEF

Far End Fault Indication for Ethernet ports

DIP Switch
SW1

Link Fault Enable/Disable

SW2-SW4

Not Connected

Power
Stand-alone

1-2

AC

100 to 240 VAC, 1.85 W

DC

-36 to -72 VDC, 1.85 W


FCAT 1000-N

Introduction

ENVIRONMENTAL
Operating temperature

0 to 50 C (32-122 F)

Storage temperature

-30 to 65 C (-22 to 149 F)

Humidity

10 to 90% Non-condensing

Fiber Optic Specifications


Module
Type

Wavelength
(nm)

Fiber Type (m)

Typical
Tx Power
(dBm)

Typical Rx
Sensitivity
(dBm)

Typical
Range (Kms)

MM

850

62.5/125 Multimode

-6

-14

0.22

MM

850

50/125 Multimode

-6

-14

0.5

SM10

1310

9/125 Single mode

-6

-18

15

SM40

1310

9/125 Single mode

-19

40

SM60

1550

9/125 Single mode

0.5

-20

60

SF15

1310/1550

9/125 Single mode SF

-6

-18

15

SF40

1310/1550

9/125 Single mode SF

0.5

-19

40

Features

Single channel standalone media converter

Media Conversion from 1000BASE-TX to 1000BASE-FX

Auto MDI-I/MDI-X copper Ethernet port

RJ-45 connector for 1000BASE-TX port

SC connector for 1000BASE-FX port

Link and Activity, FEF, LFP LED indications

FEF indication for both remote side fiber and copper

LFP propagation of both from copper to fiber and fiber to copper

Supports multi mode or single mode fiber

Single mode option available up to 60 km

Internal auto-ranging AC or DC power supply

Configuration using DIP Switches

1-3


FCAT 1000-N

Introduction

Physical Description
Figure 1 shows a 3D view of the FCAT1000-N unit in the enclosure.
The front panel of a desktop unit includes SC connector, Copper Ethernet port and several LED indicators
which display the status of power, link and activity indicators.

Figure 1: FCAT1000-N

1-4

Chapter 2
Installation and Setup

2-1


FCAT 1000-N

Installation

Installation
This chapter describes installation and setup procedures for the standalone FCAT1000-N media
converter.

Internal settings, adjustment, maintenance and repairs may be performed only by a


skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation and
maintenance of this product.
The FCAT1000-N media converter is designed for standalone installation and is delivered as a fully
assembled unit.

Package Content
The FCAT1000-N package includes the following items:

One FCAT1000-N unit

Technical documentation CD

AC or DC power cords

Installing FCAT1000-N
The installation of the FCAT1000-N media converter includes the following steps,

Connecting the unit to power mains

Connecting the SC interface

Connecting the Ethernet interface

Site Requirement and prerequisites


AC-powered FCAT1000-N units should be installed within 1.5m (5 ft) of an easily-accessible grounded
AC outlet capable of furnishing the voltage in accordance with FCAT1000-N nominal supply voltage.
DC-powered FCAT1000-N units require a -36 to -72 VDC power source, which must be adequately
isolated from the main supply.
The ambient operating temperature of FCAT1000-N should be 0 to 50C, at a relative humidity of up to
90%, non-condensing.

2-2


FCAT 1000-N

Installation

Connecting the interfaces


Figure 2 shows a typical front panel of FCAT1000-N media converter with an Ethernet interface, SC
interface and power LED.

Figure 2: Front Panel of FCAT1000-N media converter

Connecting to Power
FCAT1000-N is equipped with either AC or DC power supply. AC or DC power is supplied to
FCAT1000-N via a standard power input connector on the rear panel.

Connecting to AC Power
AC power should be supplied through the standard power cable terminated by a standard plug. The AC
power chord is provided along with the unit.
To connect AC power:
1.

Connect the power cable to the power connector on the FCAT1000-N rear panel.

2.

Connect the power cable to the mains outlet.

The unit turns on automatically upon connection to the mains.

Connecting to DC Power
DC power is supplied to FCAT1000-N via a compatible DC cable for attaching -48V DC power supply
lines. While connecting to the DC power mains, the polarity needs to be taken care as per the indications
provided on the DC cable.
The DC power cord is provided along with the unit.

Connecting the Ethernet Interface


Ethernet interface uses RJ45 connector
To connect Ethernet interface
Connect the line cable to the RJ-45 connector designated to Ethernet interface.

2-3


FCAT 1000-N

Installation

Connecting the SC Interface


The FCAT1000-N has SC interface.
To connect SC interface
Connect the cable to the designated SC interface located on the front panel.

Application
The below figures illustrates FCAT1000-N applications, It is designed for demanding network
environments to provide high speed and reliable connects. It can typically be used in a LAN,
MAN or in a Campus Network.

Figure 3: Application

2-4

Chapter 3
Operation

3-1


FCAT 1000-N

Operating FCAT1000-N

Operating FCAT 1000-N


This chapter provides the following information for FCAT1000-N Media converter

Operating procedures (Power-ON, Performance Monitoring and Power-OFF)

FCAT1000-N LED indicators

Turning on FCAT 1000-N


To turn on FCAT1000-N:

Connect the power cord to the AC/DC power mains.

The PWR indicator lights up and remains lit as long as FCAT1000-N is receiving power.
FCAT1000-N requires no operator attention once installed, with the exception of occasional monitoring
of front panel indicators. Intervention is only required when FCAT1000-N needs to be configured to its
operational requirements or diagnostic tests to be performed.

LED Indicators
The front panel of FCAT1000-N includes a series of LED indicators that shows the current operating
status of the unit.

LED Indicator description


Figure 5 shows the front panel of FCAT1000-N unit.

Figure 4: Front Panel LED indicators

3-2


FCAT 1000-N

Operating FCAT1000-N

Interface
Type

Color

Indicat
or
Name

Indicator
Meaning

Power
Supply

Green

PWR

Power Indicator

Activity

Green

ACT

Activity status

TXLNK

Copper Link

FXLNK

Fiber Link

TX-LFP

Link Fault
Propagation in
Copper

ON: LFP in Copper

FX-LFP

Link Fault
Propagation in
Fiber

ON: LFP in Fiber

TX-FEF

Far End Faul


Copper t

ON: FEF in Copper

FX-FEF

Far End Fault


Fiber

ON: FEF in Fiber

Link

LFP

FEF

Green

Green

Yellow

Function
ON: Unit is powered ON
OFF: Unit is not receiving Power
Flashing: Activity status for Ethernet port
ON: Copper Link is active
ON: Fiber Link is active

DIP Switch
SW1: Link Fault Enable/Disable
SW2-SW4: Not Connected

3-3


FCAT 1000-N

Installation

Installation
Following are the installation procedure to install FCAT1000-N

3-4

Connect a fiber patch chord Type (single/multi mode) and SC interface on


FCAT1000-N to the FX port.

Connect a CAT 5 UTP cable to the corresponding TX port and terminate it on the
Ethernet port of the terminal equipment (Typically a switch/PC/server)

Repeat step two at the remote side of the fiber.

After switching on, check if the FX link is up, or else swap TX and RX patch chord of
the corresponding FX port.

Once FX link is up, check the TX link status and ensure it is up.

Chapter 4
Appendix A

4-1


FCAT 1000-N

Safety Notices

Safety Notices
For your protection, observe the following safety precautions when setting up your equipment:

Safety Precautions
Read the following safety information thoroughly before installing the FCAT1000-N.

Always observe standard safety precautions during installation, operation and maintenance of
this product. Only qualified and authorized service personnel should carry out adjustment,
maintenance or repairs to this product.

No User-serviceable parts in the equipment.

Installation and removal of module should be done by qualified personnel only.

Follow all cautions and instructions if marked on the equipment supplied.

Do not make mechanical or electrical modifications to the equipment. MRO-TEK Limited is


not responsible for regulatory compliance of a modified MRO-TEK Limited product.

Never place an MRO-TEK Limited product near a radiator or heat register. Failure to follow
these guidelines can cause overheating and affect the reliability of the device.

Modifications to Equipment
Do not make mechanical or electrical modifications to the equipment. MRO-TEK Limited is not
responsible for regulatory compliance of a modified MRO-TEK Limited product.

Placement of the unit

Do not block or cover the opening vents of your purchased product. Never place the unit near a radiator or
heat register. Failure to follow these guidelines can cause overheating and affect the reliability of the
device.

4-2

Chapter 5
Appendix B

5-1


FCAT 1000-N

F.A.Q
Problem

Indication

Corrective Action

No Power

Main power

Check if the power supply cable is firmly connected to the main power
supply

LED is not
glowing

Check if the AC input power source is between 100 and 240VAC. (Check if
the source voltage is between 36VDC to 72VDC for a DC Box)
Check the fuse on AC mains supply

Copper link not


active

TX Link LED is
not glowing
(TX LINK)

Fiber link not


active

FX Link LED
(1000Base-FX is
not glowing)

Check whether the connected devices port is active.


Check if the cable is faulty.
Reset the device and try again
Check if the receive fiber of the local device is properly connected to the
transmit port of the remote fiber device and the transmit port to the receive
port of the remote device
Ensure that the cables are inserted properly.
Check whether the connected remote device is active.
If the problem persists, then repeat the above-mentioned steps at the remote
device.
If the link still does not come up, ensure that the fiber link is functional,
using an OTDR equipment measure the fiber loss and ensure that the loss is
less than the product power budget.
Reset the device and try again

Improper network
traffic / slowed
down traffic

5-2

Excess collisions

Verify that all devices (both FCAT and the devices interconnected by them)
are set to the same Duplex mode, 1000 Mbps data rate, and set to Auto
negotiation enable.