HUSKPAC ULTRA

Designed with CFD, highest efficiency- 74%


The 3 pass, wet back, integral furnace husk fired boiler

HUSKPAC ULTRA

Improving your business


is our business

Thermax offers products,

systems and solutions in energy


and environment engineering to
industrial and commercial
establishments around the world.
Its business expertise covers
heating, cooling, waste heat
recovery, captive power, water
treatment & recycling, air pollution
control & waste management and
performance chemicals. Thermax
brings to customers extensive
experience in industrial
applications, and expertise through
technology partnerships and
strategic alliances.

Reliable top loading

By design, top loading avoids typical problems of front loading with


single fan e.g. devastating effects like nozzle failure and bulging of
reversal chamber, caused by malfunction of damper adjustments
and pressure variation, are done away with

Nozzle failure due to erosion of nozzles.

Operating from its headquarters in


Pune (Western India), Thermax
has built an international sales &
service network spread over South
East Asia, Middle East, Africa,
Russia, UK and the US. It has a full
fledged manufacturing set up that
is certified for ISO 9001:2000, ISO
14001 and safety management
according to OSHAS (ISO 18000).
In process heat, Thermax offers a
wide range of steam boilers,
thermal oil heaters and hot water
generators. It has expertise in a
wide range of fuels - oil, gas, solid
and agro-waste/ biomass.
Supporting a broad array of
industries in generating,
transferring and conserving heat
across a host of applications,
Thermax process heat products
and systems are exported to North
and South America, South East
Asia, Middle East, Africa, Europe,
CIS, Australia, Antarctica and
SAARC.

Bulging of reversal chamber caused by


combustion taking place inside it.

Rugged & long


operating life
Special ferrules have been provided to protect
smoke tubes from abrasive husk ash. This
leads to longer life of tubes.

- a boiler designed for savings


Bubbling bed combustion
Turbulent air flow, counter to the feed of fuel
(rice husk), gives higher residence time and
enables complete combustion
when fuel is in suspension,
thus ensuring a higher
EFFICIENCY
efficiency.

74%

Nozzles designed by CFD


CFD is a sophisticated, computationally
based Design & Analysis software that helps
simulate
Flow of gases and liquids
Heat and mass transfer
Fluid structure interaction
Thus nozzles designed using CFD ensure
proper cooling and longer life.

Velocity Vectors

Temperature Plots

Typical boiler house layout


CHIMNEY

FIRING
SIDE

HUSKPAC
ASH
ROOM

Sustainable Solutions in
Energy & Environment

COOLING & HEATING DIVISION

CONTROL
PANEL

AHMEDABAD 380 006


Tel. : (079) 2657 5408 / 5341 / 7073
Fax : (079) 2657 7270
E-mail : aadmin@thermaxindia.com

BUNKER

BANGALORE 560 020


Tel. : (080) 2346 7761 - 64
Fax : (080) 2346 7760
E-mail : adminblr@thermaxindia.com

General arrangement

CHENNAI 600 018


Tel. : (044) 2435 3831 - 34
Fax : (044) 2435 3841
E-mail : chennaidivsupp@thermaxindia.com
HYDERABAD 500 482
Tel. : (040) 2339 6820, 2331 0254
Fax : (040) 2331 2335
E-mail : hyd_sec@thermaxindia.com

HUSKPAC

KOLKATA 700 016


Tel. : (033) 2282 6711 - 13
Fax : (033) 2282 6796
E-mail : ksgroup@thermaxindia.com
L

MUMBAI 400 016


Tel. : (022) 2204 5391, 2204 5324
Fax : (022) 2204 0859
E-mail : madmin@thermaxindia.com

Technical specifications
Parameter

Unit

HP-20BB

HP-30BB

Maximum output (F&A 100 deg. C)

Kg/hr

2000

3000

Safety valve set pressure*


Fuel
Efficiency (Parboiled Rice Husk)

4000

Kg/cm2

10.54/17.54

Paddy Husk, Gross Calorific Value of


3100 kcal/kg, Moisture up to 10%.

Fuel consumption on MCR

Kg/hr

Efficiency (Raw Rice Husk)

Fuel consumption on MCR

Kg/hr

Power supply option

HP-40BB

74%
471

NEW DELHI 110 057


Tel. : (011) 2614 5319, 2614 5701
Fax : (011) 2614 5311, 2614 8679
E-mail : psupport@thermaxindia.com
PUNE 411 019
Tel.: + 91-20-2747 5941
Fax: + 91- 20-2747 2049/2747 5679
E-mail : shrirangd@thermaxindia.com
Your nearest Thermax Channel Associate

706

942

72%
484

726

968

220/380/415 V AC 6%, 50/60 Hz 3%, 3 Phase

Total electrical connected load*

hp

14

20

22.5

Length (L)

mm

4100

5200

5500

Width (W)

mm

3700

4000

4500

Height (H)

mm

3800

4100

4600

Typical boiler house dimensions (AxB)

mtr.

22 x 11

23 x 11

24 x 11

Dry weight of pressure part

Tons

12

15

23

INTERNATIONAL OFFICES
n UK n USA n UAE n Thailand n Indonesia n Russia
n Kazakstan n Kenya n Saudi Arabia n Nigeria
n Malaysia n Bangladesh n Sri Lanka n Chile

www.thermaxindia.com

Thermax Business Portfolio


Water & Waste Solutions

Note: *Connected load includes FD fan, pneumatic conveying fan, control panel, vibro feeder & feed water pump.
Electrical connected load will change with addition of dust collector.

IBR
In view of our constant endeavour to improve the quality of our products, we reserve the right to alter or change specifications without prior notice.
All photographs shown in this publication are representative in purpose, and to be used for reference only. For actual details and specifications,
please refer to Thermax offer document.

Air Pollution Control


Chemicals
Boilers & Heaters
Absorption Cooling
Captive Power

Вам также может понравиться