Вы находитесь на странице: 1из 4

CMCI

CEMTEC EPOQUA II
TWO COMPONENT WATER
BASED EPOXY
PRODUCT DESCRIPTION
CEMTEC EPOQUA II is a two component, water
based epoxy coating available in either high gloss
or satin sheens. The epoxy resin is cured with an
acrylic curative to form a smooth, tough, tile like
coating which exhibits outstanding chemical stain
and abrasion resistant properties. CEMTEC
EPOQUA II offers the durability and stain
resistance which in the past has only been
available with two component solvent based epoxy
finishes.
CEMTEC EPOQUA II has excellent resistance to
high moisture and humidity. This unique water
reducible, low odour epoxy coating contains no
mercurial compounds and effectively resists
mildew and many strains of fungus growth.
CEMTECEPOQUA II is formulated to meet all
existing Federal and States air pollution control
methods.
BASIC USES
CEMTEC EPOQUA II was specifically developed
for wall or floor surfaces which are subjected to
repeated scrubbing and where long term stain
resistance is of prime importance. CEMTEC
EPOQUA II has excellent resistance to many
chemicals, oil and other substances. Refer to
paragraph entitled Stain Resistance for a list of
those materials which have been tested.
CEMTEC EPOQUA II can be applied to dry wall,
plaster, and to surfaces which have been
previously coated. The bond strength of CEMTEC
EPOQUA II to these substrates is excellent. This
abrasion resistant coating is recommended for use
in schools, hospitals, athletic facilities, commercial
kitchens, public restrooms and in wet areas such
as showers, locker rooms, dairies, food processing
plants, and other high humidity areas. It is also
an excellent industrial maintenance coating for use
on equipment, railings, machinery etc. CEMTEC
EPOQUA II is authorised by the USDA for use in
Federally Inspected meat and poultry processing
plants.
CEMTEC EPOQUA II Clear can also be reduced
100% with water for use over concrete floors as a
sealer or primer under numerous topcoats.
COLOURS
CEMTEC EPOQUA II is available in standard
White and Clear.

PERFORMANCE & ADVANTAGES


Abrasion Resistance
CEMTEC EPOQUA II has high resistance to
abrasion when compared to enamels or other types
of epoxy finishes. A loss of only 80 to90 milligrams
resulted when tested on a Taber Abraser, using
CS-17 abrasive wheels with 1000 gm weights at
1000 revolutions. Tested in accordance with ASTM
D 4060.
Scrub Resistance
Gardener Straight-line Washability and Abrasion
Machine - Test Machine imparts a back and forth
motion to a holder containing a bristle brush and
mild soap solution that slides on the test panel.
After 2,000 strokes on panels coated with
CEMTEC EPOQUA II there was no deleterious
effect on the coating. Tested in accordance with
Federal Test Method Standard No. 141 A, method
6142.
Mildew Resistance
CEMTEC EPOQUA II has zero rating, no growth
observed when tested for resistance to the
following fungi : Aspergillus niger, Penicillium
funiculosum, Chaetomium globosum, Trichoderma
sp and Pullularia pullulans, tested in accordance
with ASTM G 21.
Conformance to Environmental Pollution
Standards
CEMTEC EPOQUA II is formulated to meet all
existing Federal and State air pollution control
standards. It is water reducible, exhibiting very low
odour. There are no toxic solvents released as
the coating cures, which is a common problem for
interior use of solvent based epoxy finishes.
Resistance to High Humidity
CEMTEC EPOQUA II showed no signs or blistering
or softening on exposure to 100% humidity in the
QCT condensation cabinet after 48 hours, when
cured for 24 hours at 75 Deg.F. (24 Deg.C.), 50%
RH tested in accordance with ASTM D 2247.
Stain Resistance
The following materials had no effect on CEMTEC
EPOQUA II. Test panels were first scrubbed for
2000 strokes on a Gardner Straight-line
Washability and Abrasion Machine using a mild
soap solution and bristle brush. Panels were dried
and staining materials applied and allowed to set
for 24 hours before removal. All of the following
materials were removed with water rinsing. No
staining or other adverse affects, such as
discoloration, softening or blistering of the coating
were observed:

Quality Construction Chemicals


CONSTRUCTION MATERIAL CHEMICAL INDUSTRIES P.O. Box 7137, Dammam 31462, Saudi Arabia
Tel: 00966-3-8471450; Fax: 00966-3-8471575; Email: tech@cmci-sa.com Web: www.cmci-sa.com

Ketchup
Grape Juice
Lipstick
Vegetable Oil
HeavyDuty Detergent
Blood

Toluene
Ethyl Acetate
50% IPA
Methanol
Xylol

20% Sodium Chloride.


10% Ammonium Hydroxide
Conc:Ammonium Hydroxide
10% Sodium Hydroxide
50% Sodium Hydroxide
10%Citric Acid.

The following materials left a stain, which was completely removed with the cleaning method
listed below :
Liquid Shoe Polish
Crayon
Ball Point Pen
Mustard
Marking Pen

Complete removal with detergent


Complete removal with detergent.
Complete removal with 50% IPA
Complete removal with abrasive cleaner
Complete removal with abrasive cleaner

No effect on coating
No effect on coating.
No effect on coating.
Slight loss of gloss.
Slight loss of gloss.

The above tests were conducted in accordance with ASTMD 2299.

USDA Standards
CEMTEC EPOQUA II is authorised by USDA for
use in Federally Inspected meat and poultry
processing plants.
Bond Strength
CEMTEC EPOQUA II exhibits greater adhesive
strength than the cohesive strength of the following
substrates. Test was conducted using a Gardner
Adhesion Tester which measures the bond strength
in pounds per square inch and determines whether
the failure is in adhesive strength of the coating or
cohesive strength of the backing material.
Asbestos cement Board failed at 125 psi (.86 MPa).
Plywood failed at 250 psi ( 1.72 MPa). Drywall and
concrete failed at less than 50 psi (.34 MPa). With
all the materials tested, CEMTEC EPOQUA II
could not be separated from the substrates.
Flame Spread Rating
CEMTEC EPOQUA II has NFPA Class A and
UBC Class I ratings on non-combustible surfaces
with Flame Spread of less than 25 and fuel
Contribution / smoke Density values of zero.
Tested in accordance with ASTM E 84.
Water Absorption
14 day immersion in distilled water at 75 Deg.F.
(24 Deg.C.) - CEMTEC EPOQUA II test specimens
had less than 5% weight gain. No swelling or
softening of the film was observed. Tested in
accordance with ASTM D 570.
Mar Resistance
The dense, non-porous properties of CEMTEC
EPOQUA II produce a seamless Tile like surface
without the disadvantage of bacteria and oil
collecting mortar joints. It is highly scratch
resistance when compared to other types of
coatings.

PACKING & MIXING


CEMTEC EPOQUA II is a two component material
available in 1 gallon kits & 20 ltrs pails. Mix
Part A with pre-measured unit Part B. Allow
mixture to stand a minimum of 30 minutes induction time when temperatures are between 65
Deg.F. and 90 Deg.F. If temperatures are between
55 Deg.F and 65 Deg.F. allow one hour induction
time. Complete mixing and induction time are
essential for CEMTEC EPOQUA II to achieve
full cure. Useable pot life is 36 hours up to 90
Deg.F. Higher temperatures will reduce pot life.
If thinning is desired add a small amount of clean
water. Do not add new material to old material
which will not be used up within the stated pot
life.
Material should be stored at temperatures between
40 Deg.F. (4 Deg.c.) and 100 Deg.F. (38 Deg.C).
Do not open containers until ready to use the
material.
SURFACE PREPARATION
All surfaces must be clean, dry and free of any
oily residue which will interfere with proper adhesion.
On surfaces to be repainted, careful examination
must be made to ensure that any accumulated
oil, smoke, wax or other material which could
interfere with adhesion has been removed.
New Wall
All taped joints and nail or screw heads must be
completely finished and sanded smooth. Cracks,
holes or imperfections shall be repaired with drywall
joint compound to an even surface, matching the
plane and texture of the adjacent areas. Do not

Quality Construction Chemicals


CONSTRUCTION MATERIAL CHEMICAL INDUSTRIES P.O. Box 7137, Dammam 31462, Saudi Arabia
Tel: 00966-3-8471450; Fax: 00966-3-8471575; Email: tech@cmci-sa.com Web: www.cmci-sa.com

CMCI

CMCI

raise nap of paper of drywall. Priming of new


drywall surface is not required.
Existing Painted Drywall and Plaster
Dull any glossy surfaces by scuff-sanding or washing
with cleaning concentrate or water. Rinse and allow
to dry thoroughly. Examine surfaces to be certain that
all foreign material such as dirt, grease, or soap has
been removed. Remove all loose or peeling paint by
scraping or sanding, feathering edges of sound paint.
Repair all cracks and holes with filling compound to
match the plane and texture of adjacent areas.
New Concrete Block Masonry
Masonry surfaces shall be wire brushed clean to
remove mortar droppings, glaze, scale, efflorescence
and loose particles. Follow brushing by sweeping
entire surface with a stiff broom to remove dust and
other residual matter. In some cases, masonry
surfaces may require washing with acid or detergent
to remove efflorescence. If desired, masonry block
may then be filled with an approved block filler. Apply
block filler to produce a surface free of pinholes and
other voids.
New Plaster
Cracks, holes or imperfections shall be filled with
proper patching material, matching the plane and
texture of the adjacent areas. Do not paint over
surfaces when the moisture content exceeds 8% as
determined by a moisture meter. Plaster shall be
allowed to age at least 30 days before application of
CEMTEC EPOQUA II. Priming of new plaster surface
is not required.
New Concrete Wall Surfaces
Where traces of form oil or releasing agents are
encountered, it shall be necessary to remove this
material with
or equivalent cleaner following
manufacturers directions. Fill all cracks and voids
with patching compound flush with surface. All
concrete surfaces shall be swept or blown down to
remove dust and contamination.
Existing painted concrete and concrete Block
Masonry
Remove all blistering and peeling paint by scraping,
sanding or wire brushing. Chalking shall be removed
to sound surface. Any surface showing mildew shall
be scrubbed with a solution of 1 cup household
bleach and 1 gallons of water.
Rinse and allow
to dry thoroughly. Repair all cracks with patching
compound flush with surface. Depending upon
surface texture, an approved block filler may be
required to achieve a surface free of voids.
New Metal
Loose mill scale and rust shall be removed by wire
brush, sandpaper or other mechanical means.
Uncoated ferrous metal shall then be thoroughly
cleaned with
Shop coated ferrous metal shall
be thoroughly cleaned. Spot prime field connections,
welds, and bare metal with
Feather edges of
sound primer prior to spot priming.
Existing Painted Metal
Painted surfaces in sound condition shall be

thoroughly cleaned with a solution of


or equivalent
cleaner and water. Rinse and allow to dry thoroughly.
Dull glossy surfaces by scuff sanding. Remove rust
and loose paint to bare metal by sanding, feathering
edges of adjacent sound paint. Spot prime all bare
metal surfaces with
New Wood
Wood shall be sanded smooth and dusted clean.
Fill nail holes, cracks, open joints and other
imperfections with putty. Sand smooth when dry and
sweep or blow down to remove sawdust and
contamination.
Existing Painted Wood
Painted surfaces in sound condition shall be
thoroughly cleaned as specified above for existing
painted metal. Remove loose, blistered, checked or
alligatored paint to bare wood by sanding, feathering
edges of adjacent sound paint. Repair all cracks or
holes with putty and sand to smooth surface when
dry. Sweep or blow down to remove sawdust and
contamination.
APPLICATION
CEMTEC EPOQUA II may be applied by brush, roller
or airless spray. Airless spray is the preferred method
of application.
Any airless spray equipment capable of 2,000 psi
(13,780 kPa) and 1 gallon per minute (3.8l/minute)
delivery can be used for applying CEMTEC EPOQUA
II. A reversible self-cleaning spray tip with orifice size
of .015 to .019 (.38 to .48 mm) and minimum 40
degree fan angle is recommended.
Before spraying, flush equipment with a mixture of
water and lacquer thinner or water and Methyl Ethyl
Ketone (MEK) to prevent contamination.
For spray application, apply one ( 1 ) coat at a
minimum coverage rate of 150 to 200 sq.ft. per gallon
g(3.7 to 4.9m2 /l.) This coverage will result in a total of
2.8 to 3.7 dry mils (71 to 94 dry microns).
For brush or roller application and for areas which
are subjected to hard use or frequent wash down,
apply two ( 2 ) separate coats at a minimum coverage
rate of 200 to 250 sq.ft. per gallon (4.9 to 6.1m2/l).
This total coverage rate will result in 4.5 to 5.6 dry
mils ( 114 to 142 microns). Allow a minimum of 24
hours drying time between coats.
Before painting, wet the brush or roller with clean

water, then shake or sqeeze out the excess water.


Do not roll or brush out excessively.
Two ( 2 ) separate coats should be sprayed,
brushed or roller applied to new or bare drywall,
plaster, wood, concrete or masonry surfaces when
the first coat is used as a primer. CEMTEC
EPOQUA II is its own best primer on these
substrates because it retains the chemical and
water resistant properties of the entire coating
system.
Brush or roller are easily cleaned with soapy water.
Clean equipment with water and final flush with a
mixture of water and Lacquer Thinner or water and
Methyl Ethyl Ketone (MEK).
APPLICATION OVER HORIZONTAL SURFACES

Quality Construction Chemicals


CONSTRUCTION MATERIAL CHEMICAL INDUSTRIES P.O. Box 7137, Dammam 31462, Saudi Arabia
Tel: 00966-3-8471450; Fax: 00966-3-8471575; Email: tech@cmci-sa.com Web: www.cmci-sa.com

CEMTEC EQPOAUA II makes an effective floor


finish, with or without non-skid aggregate, on
any horizontal application requiring a durable,
non-toxic coloured topping. Surfaces must be
clean and dry, and free of any oil, grease, dirt
and other contaminants. Wash thoroughly with
or equivalent cleaner and rinse thoroughly.
Smooth trowelled concrete floors or other dense
surfaces must first be either sandblasted or acid
etched to open the surface and allow for proper
adhesion.
Reduce the first coat of CEMTEC EPOQUA II 50%
with water to allow maximum penetration. Apply
the reduced material by brush, roller or spray at
approximately 250 sq.ft. per gallon. After allowing
to dry, apply two full strength coats at 200 to 250
sq.ft. per gallon per coat. For applications requiring
a non-skid finish, apply two coats of CEMTEC
EPOQUA II textured which incorporates a fine,
rounded silica for slip resistance and east in
cleanability. Thoroughly mix to disperse the sand
evenly throughout the container prior to rolling the
material onto the floor. For high use areas or for
added protection over the colour coats, a topcoat

of CEMTEC EPOQUA II clear gloss or satin may


be applied at approx. 300 sq.ft. per gallon.
LIMITATIONS AND PRECAUTIONS
CEMTEC EPOQUA II should not be applied over
wet surfaces or applied under high humidity
conditions. CEMTEC EPOQUA II must be fully
cured before being subjected to high humidity or
moisture conditions. Full cure for maximum
abrasion, chemical and moisture resistance will
usually develop with 7 days.
CEMTEC EPOQUA II Part A and Part B will both
freeze at temperatures below 32 Deg.F. (0 Deg.C.).
Do not ship or store unless protection from freezing
is available.
Do not apply CEMTEC EPOQUA II at
temperatures below 55 Deg.F. (13 Deg.C.).
CEMTEC EPOQUA II requires complete
evaporation of water to cure. Cool temperatures
and high humidity retard cure.
Use only in a well ventilated area. Avoid breathing
of vapour or spray mist. During spray operations,
approved (MSHA / NIOSH) chemical cartridge
respirator should be worn. Avoid contact with eyes
and skin.

TYPICAL PROPERTIES
Mixing Ratio

: Approx. 16 Part A to 1 Part B (16A:1B)

Mixed Useable Pot Life : 36 hours for spray, brush or roller applications at 75 Deg.F.(24 Deg.C.)50% R.H.
Solids by Weight

: 47%

Solids by Volume

: 35% +/-2

Flash Point

: Part A > 200 Deg.F. (93 Deg.C.) & Part B > 200 Deg.F. (93 Deg.C.)

Flame Spread Rating

: NFPA Class A and UBC Class I over non-combustible substrates (ASTM E 84).

Gloss

: 80+ (20 Deg.C.Gardner) (ASTM D 523)

Hardness

: F Pencil (ASTM D3363)

Permeance

: 5.3 Perms at 6 mils ( ASTM E 398)

Permeability

: 0.032 Perm Inches (ASTM E 398)

Abrasion Resistance

: 80 - 90 milligram weight loss using CS - 17 abrasive wheels


with 1000 gm weights at 1000 revolutions (ASTM D 4060)

Dry Time

: 2 - 4 hours - Tack Free at 75 Deg.F.(24 Deg.C.), 50% RH

Cure Time

: 7 days to develop ultimate film properties at 75 Deg.F. (24 Deg.C.), 50% R.H.

Temperature Limits
(for normal service
conditions)

: -30 Deg.F. to 150 Deg. F. (-34 Deg.C to 66 Deg.C.)

Quality Construction Chemicals


CONSTRUCTION MATERIAL CHEMICAL INDUSTRIES P.O. Box 7137, Dammam 31462, Saudi Arabia
Tel: 00966-3-8471450; Fax: 00966-3-8471575; Email: tech@cmci-sa.com Web: www.cmci-sa.com

CMCI