Вы находитесь на странице: 1из 63

Annex A

Commission on Audit
Special Services Sector
TECHNICAL SERVICES OFFICE
Reference No.:
Project Name:
Location:
Contracting Parties:

A021913/ 211
Supply, Delivery, Installation and Implementation of the Asset Information Management Program
Department of Finance, 4th floor DOF building, Roxas Boulevard cor. P. Ocampo St., Manila
INDRA PHILIPPINES, INC. UNDER A JOINT VENTURE AGREEMENT WITH PHILCOX (PHILIPPINES) INCORPORATED

EVALUATION WORKSHEET
Item
No.

1.0
1.1

Description

Hardware
Blade Server
Blade Server - General
Specification

Source Documents

Contract
Detailed breakdown of
Contract/PO/JO
Amount
ABC breakdown

Contract/PO/JO
specifications/
requirements
Agency technical
specifications/
requirements (per bid
docs)
Technical
specifications (winning
bidder)
Approved detailed
drawings/ layout if

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Contract

Information/ Data
Analysis

Proposed server blades for


hosting applications should
have adequate memory DIMMS
slots for dense memory
configuration (at least
4GB/CPU core) and support at
least 8 network ports, 2 fibre
channel (FC) ports
concurrently.
Memory DIMMS must not be
fully populated to ensure future
upgrade is possible.
Blade Server should have at
least 12 Memory DIMM Slots

Comply.
HP Proliant Servers

Blade Server should have a


minimum of Two (2) hot-plug/
hot-swap small form factor
(SFF) drive bays
Blade Server should have
support for SAS, SATA, and

Comply.
HP Proliant Servers

Comply.
HP Proliant Servers
Comply.
HP Proliant Servers

Comply.
HP Proliant Servers

Proposed server blades for


hosting applications should
have adequate memory DIMMS
slots for dense memory
configuration (at least
4GB/CPU core) and support at
least 8 network ports, 2 fibre
channel (FC) ports
concurrently.
Memory DIMMS must not be
fully populated to ensure future
upgrade is possible.
Blade Server should have at
least 12 Memory DIMM Slots

Complying

Blade Server should have a


minimum of Two (2) hot-plug/
hot-swap small form factor
(SFF) drive bays
Blade Server should have
support for SAS, SATA, and

Complying

Complying
Complying

Complying
1

Item
No.

Description

Source Documents

applicable
Bid documents (terms
of purchase, penalty
clause, warranty, etc.)
Certificate of exclusive
distributorship, if
applicable
Approved Terms of
Reference

Six (6) Units Blade Server


- Staging Server

Submitted
Yes
No

Approved ISSP

Approved APP

Copy of the Joint


Venture Agreement

Agency Requirements/
Specifications

SSD hard drives


Blade Server should support
Hot-Pluggable/Hot Swappable
HDD
RAID Controller should
support RAID Levels 0 and 1
Blade Serve should support a
minimum of dual port
10Gigabit Ethernet Adapter
add-on expansion card
Blade Server should have an
integrated Graphics Controller
Card
Blade Server should support a
minimum of single slot USB
2.0 port
Blade Server should have an
integrated management port for
ease of administration
Blade Servers should be
capable of handling virtualized
workloads
Server warranty should include
the following:
Three (3) Years for Parts, Three
(3) Years for Labor and Three
(3) Years for on-site support.
Support should be available on
a 24x7 basis
Blade server should have
minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the

Winning Bidders
Specifications

Comply.
HP Proliant Servers
Comply.
HP Proliant Servers
Comply.
HP Proliant Servers
Comply.
HP Proliant Servers
Comply.
HP Proliant Servers
Comply.
HP Proliant Servers
Comply.
HP Proliant Servers
Comply.
HP Proliant Servers

Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7

Contract

SSD hard drives


Blade Server should support
Hot-Pluggable/Hot Swappable
HDD
RAID Controller should
support RAID Levels 0 and 1
Blade Serve should support a
minimum of dual port
10Gigabit Ethernet Adapter
add-on expansion card
Blade Server should have an
integrated Graphics Controller
Card
Blade Server should support a
minimum of single slot USB
2.0 port
Blade Server should have an
integrated management port for
ease of administration
Blade Servers should be
capable of handling virtualized
workloads
Server warranty should include
the following:
Three (3) Years for Parts, Three
(3) Years for Labor and Three
(3) Years for on-site support.
Support should be available on
a 24x7 basis
Blade server should have
minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the

Information/ Data
Analysis

Complying
Complying
Complying

Complying
Complying
Complying
Complying
Complying

Complying

Complying
Complying
2

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

minimum and upgradeable


Blade Server should have a
minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System

Server
Comply.
HP Proliant BL460c G7
Server

Blade server should have


minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the
minimum and upgradeable
Blade Server should have a
minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System

Comply.
HP Proliant BL460c G7
Server

Blade server should have


minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the
minimum and upgradeable

Comply.
HP Proliant BL460c G7
Server

Comply.
HP Proliant BL460c G7
Server

Contract

minimum and upgradeable


Blade Server should have a
minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System

Information/ Data
Analysis

Complying

Complying

Two (2) Units Blade


Server ETL Server

Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server

Blade server should have


minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the
minimum and upgradeable
Blade Server should have a
minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System

Complying

Blade server should have


minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the
minimum and upgradeable

Complying

Complying
Complying
Complying

Complying

Two (2) Units Blade


Server - Database Server

Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server

Complying
Complying

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Blade Server should have a


minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System

Comply.
HP Proliant BL460c G7
Server

Blade server should have


minimum of four physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the
minimum and upgradeable
Blade Server should have a
minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System

Comply.
HP Proliant BL680c G7
Server

Blade server should have


minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the

Comply.
HP Proliant BL460c G7
Server

Comply.
HP Proliant BL460c G7
Server

Contract

Information/ Data
Analysis

Blade Server should have a


minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System

Complying

Blade server should have


minimum of four physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the
minimum and upgradeable
Blade Server should have a
minimum of I46GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System

Complying

Blade server should have


minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 16GB
1333MHZ of RAM at the

Complying

Complying

Two (2) Units Blade


Server - Business
Intelligence Server

Comply.
HP Proliant BL680c G7
Server
Comply.
HP Proliant BL680c G7
Server
Comply.
HP Proliant BL680c G7
Server
Comply.
HP Proliant BL680c G7
Server

Complying
Complying
Complying

Complying

Two (2) Units Blade


Server - Business
Intelligence Portal Server

Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7

Complying
Complying
4

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

minimum and upgradeable


Blade Server should have a
minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System.

Server
Comply.
HP Proliant BL460c G7
Server

Blade server should have


minimum of one physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 4GB
1333MHZ of RAM at the
minimum and upgradeable.
Blade Server should have a
minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Microsoft Server 2008 R2
Operating System

Comply.
HP Proliant BL460c G7
Server

Blade server should have


minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 8GB
1333MHZ of RAM at the
minimum and upgradeable

Comply.
HP Proliant BL460c G7
Server

Comply.
HP Proliant BL460c G7
Server

Contract

minimum and upgradeable


Blade Server should have a
minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Linux Operating System.

Information/ Data
Analysis

Complying

Complying

One (1) Unit Blade Server


- Backup Server

Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server

Blade server should have


minimum of one physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 4GB
1333MHZ of RAM at the
minimum and upgradeable.
Blade Server should have a
minimum of 146GB usable
Capacity HDD and a minimum
of 10K RPM disk speed
Blade Server should support
Microsoft Server 2008 R2
Operating System

Complying

Blade server should have


minimum of two physical Intel
Xeon processors with at least
two cores per processors.
Processor speed should be
2.0GHZ and 8MB L3 Cache at
the minimum
Blade Server should have 8GB
1333MHZ of RAM at the
minimum and upgradeable

Complying

Complying
Complying
Complying

Complying

One (1) Unit Blade Server


SIEM Server

Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server

Complying
Complying

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Blade Server should have a


total of two (2) 300GB with
15K RPM Disk Speed
Blade Server should support
Linux Operating System
1.2

Blade Enclosure/Chassis

Winning Bidders
Specifications

Comply.
HP Proliant BL460c G7
Server
Comply.
HP Proliant BL460c G7
Server

Contract

Blade Server should have a


total of two (2) 300GB with
15K RPM Disk Speed
Blade Server should support
Linux Operating System

The blade enclosure should


allow scalability beyond 8
network ports and 2 FC ports.

Information/ Data
Analysis

Complying
Complying
Not specifically
stated in the technical
proposal of the
winning bidder.

Three (3) Units Blade


Server Chassis
Proposed Blade Server Chassis
should have the necessary
hardware, firmware and
software to ensure blade servers
can switch to any standby
server blades without re-cabling
of network cables. It must be
able to achieve this even if the
chassis is connected to more
than 1 physical network or
VLANs. The Blade Server
Chassis should be compatible to
all blade servers delivered.
The interconnect modules in the
Blade Server Chassis should
support virtualization of
Ethernet and Fibre Channel
connection.
Provide detailed architecture of
the Ethernet, Fibre Channel,
Virtualization.
Proposed Blade Server Chassis
should have individual remote
management capability for
remote server power up/power
down, remote console view,
remote media (CD-ROM, ISO)
mounting

Comply.
HP BladeSystem c7000
Enclosure

Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure

Proposed Blade Server Chassis


should have the necessary
hardware, firmware and
software to ensure blade servers
can switch to any standby
server blades without re-cabling
of network cables. It must be
able to achieve this even if the
chassis is connected to more
than 1 physical network or
VLANs. The Blade Server
Chassis should be compatible to
all blade servers delivered.
The interconnect modules in the
Blade Server Chassis should
support virtualization of
Ethernet and Fibre Channel
connection.
Provide detailed architecture of
the Ethernet, Fibre Channel,
Virtualization.
Proposed Blade Server Chassis
should have individual remote
management capability for
remote server power up/power
down, remote console view,
remote media (CD-ROM, ISO)
mounting

Complying

Complying

Complying
Complying

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

The Blade Server Chassis


should have a DVD Drive
There should be redundant
Blade Server Chassis
management modules
The Blade Server Chassis
management software must
provide real-time and historical
power consumption information
in Watts or BTU/hr. Such
information should also be
integrated to the Integrated
Infrastructure Management
Software for reporting and
monitoring purposes
The Blade Server Chassis
management software must
provide detailed chassis view of
the server blades, interconnect
modules, fans and power
supplies.
Proposed server blades and
chassis must have a costeffective upgrade path to
10GbE network. Blade Servers
must provide 10GbE network
ports and Blade Enclosure
Interconnects must provide at
least 5 uplink ports. Each
uplink ports must support 1
GbE or 10Gbe speed using
SFP+ modules.
Details of the upgrade (Change
of switches modules or
connectors) must be
documented
The Blade Server Chassis must
provide a mean to cap the
maximum power draw.

Winning Bidders
Specifications

Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure

Comply.
HP BladeSystem c7000
Enclosure

Comply.
HP BladeSystem c7000
Enclosure

Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure

Contract

Information/ Data
Analysis

The Blade Server Chassis


should have a DVD Drive

Complying

There should be redundant


Blade Server Chassis
management modules
The Blade Server Chassis
management software must
provide real-time and historical
power consumption information
in Watts or BTU/hr. Such
information should also be
integrated to the Integrated
Infrastructure Management
Software for reporting and
monitoring purposes
The Blade Server Chassis
management software must
provide detailed chassis view of
the server blades, interconnect
modules, fans and power
supplies.
Proposed server blades and
chassis must have a costeffective upgrade path to
10GbE network. Blade Servers
must provide 10GbE network
ports and Blade Enclosure
Interconnects must provide at
least 5 uplink ports. Each
uplink ports must support 1
GbE or 10Gbe speed using
SFP+ modules.
Details of the upgrade (Change
of switches modules or
connectors) must be
documented
The Blade Server Chassis must
provide a mean to cap the
maximum power draw.

Complying
Complying

Complying

Complying

Complying

Complying

Item
No.

1.3

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

The Blade Server Chassis must


provide N+N power
redundancy.
The Blade Server Chassis must
provide zoned cooling for the
blades for efficient cooling and
reduced power.
The Proposed Blade Server
Chassis must have a minimum
height of 6U
The Proposed Blade Server
Chassis must be able to
accommodate a minimum of
Six (6) Blade Servers
The Blade Server Chassis must
support the Fibre Channel
connection requirement of the
Blade Servers
The Proposed Blade Server
Chassis must have a minimum
of 1200W (high-line) or 800900W (low-line) Power Support
Integrated in the Chassis
Proposed Blade Server Chassis
should accommodate a
minimum of 60% of total
cooling capacity
Blade Server warranty should
include the following: Three (3)
Years for Parts, Three (3) Years
for Labor and Three (3) Years
for on-site support. Support
should be available on a 24x7
basis

Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure

The Proposed Rack should be


able to contain all hardware
components specified without

HP TFT7600 G2 KVM
Console

Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure
Comply.
HP BladeSystem c7000
Enclosure

Contract

Information/ Data
Analysis

The Blade Server Chassis must


provide N+N power
redundancy.
The Blade Server Chassis must
provide zoned cooling for the
blades for efficient cooling and
reduced power.
The Proposed Blade Server
Chassis must have a minimum
height of 6U
The Proposed Blade Server
Chassis must be able to
accommodate a minimum of
Six (6) Blade Servers
The Blade Server Chassis must
support the Fibre Channel
connection requirement of the
Blade Servers
The Proposed Blade Server
Chassis must have a minimum
of 1200W (high-line) or 800900W (low-line) Power Support
Integrated in the Chassis
Proposed Blade Server Chassis
should accommodate a
minimum of 60% of total
cooling capacity
Blade Server warranty should
include the following: Three (3)
Years for Parts, Three (3) Years
for Labor and Three (3) Years
for on-site support. Support
should be available on a 24x7
basis

Complying

The Proposed Rack should be


able to contain all hardware
components specified without

Complying

Complying

Complying
Complying

Complying

Complying

Complying

Complying

Server Rack
Two (2) Unit Server Rack

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

need of additional space or rack


The Proposed Rack should have
a KVM setup including mouse,
keyboard and monitor that will
be able to support all blade
servers
1.4

Winning Bidders
Specifications

HP TFT7600 G2 KVm
Console

Contract

need of additional space or rack


The Proposed Rack should have
a KVM setup including mouse,
keyboard and monitor that will
be able to support all blade
servers

Information/ Data
Analysis

Complying

Storage Area Network


One (1) Unit Storage Area
Network
Proposed Storage Area Network
(SAN) should have at least 28
TB RAW Capacity upgradable
to 80 TB or more
Proposed Storage Area Network
should have native Support to
Raid Levels 1, 0, 1+0 and 5
Must be able to accommodate
SAS or SATA Hard Drives
Disk should have a minimum of
10K RPM Speed
Must have a minimum of
8GBPS Fibre channel
connectivity
Ability to dynamically move
volumes to different storage
tiers
Must have Thin provisioning
features
Must have a minimum of 4GB
cache
Must have a minimum of 2
controllers with failover
capability
Must be able to combine RAID
types on the same spindles.
Must offer reservationless
snapshots.
Must have many-to-many
sparing - not isolated spare

Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400

Proposed Storage Area Network


(SAN) should have at least 28
TB RAW Capacity upgradable
to 80 TB or more
Proposed Storage Area Network
should have native Support to
Raid Levels 1, 0, 1+0 and 5
Must be able to accommodate
SAS or SATA Hard Drives
Disk should have a minimum of
10K RPM Speed
Must have a minimum of
8GBPS Fibre channel
connectivity
Ability to dynamically move
volumes to different storage
tiers
Must have Thin provisioning
features
Must have a minimum of 4GB
cache
Must have a minimum of 2
controllers with failover
capability
Must be able to combine RAID
types on the same spindles.
Must offer reservationless
snapshots.
Must have many-to-many
sparing - not isolated spare

Complying

Complying
Complying
Complying
Complying
Complying
Complying
Complying
Complying
Complying
Complying
Complying
9

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

drives.
If using Windows as the OS
kernel, must provide
certification that OS is not
attackable by Windows viruses
and must certify they've never
sent out release notes warning
of virus attacks to their storage
OS.
Must offer battery-backed
cache, not battery backup to
disk.
If a single back-end loop goes
down, all disks must still be
accessible by both controllers
without any controller failover
or trespassing being invoked.
Must have wide-striping (the
ability to stripe data across all
the disks in the array if
necessary), and the wide
striping must function
automatically without manual
set up and management apart
from normal array
configuration steps
Controller failover must be
built-into the array and not a
licensed software product.
Must be able to automatically
stripe data across all the disks
in the array.
LUNs must not go offline if the
volume runs out of free space.
Proposed Storage Area Network
should be able to be hosted on
the Proposed Server Rack
Windows and Linux Operating
System must be supported by
the Storage Area Network

Winning Bidders
Specifications

Comply.
HP P10000 3PAR V400

Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400

Comply.
HP P10000 3PAR V400

Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400
Comply.
HP P10000 3PAR V400

Contract

drives.
If using Windows as the OS
kernel, must provide
certification that OS is not
attackable by Windows viruses
and must certify they've never
sent out release notes warning
of virus attacks to their storage
OS.
Must offer battery-backed
cache, not battery backup to
disk.
If a single back-end loop goes
down, all disks must still be
accessible by both controllers
without any controller failover
or trespassing being invoked.
Must have wide-striping (the
ability to stripe data across all
the disks in the array if
necessary), and the wide
striping must function
automatically without manual
set up and management apart
from normal array
configuration steps
Controller failover must be
built-into the array and not a
licensed software product.
Must be able to automatically
stripe data across all the disks
in the array.
LUNs must not go offline if the
volume runs out of free space.
Proposed Storage Area Network
should be able to be hosted on
the Proposed Server Rack
Windows and Linux Operating
System must be supported by
the Storage Area Network

Information/ Data
Analysis

Complying

Complying
Complying

Complying

Complying
Complying
Complying
Complying
Complying
10

Item
No.

1.5

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Contract

Information/ Data
Analysis

SAN warranty should include


the following: Three (3) Years
for Parts, Three (3) Years for
Labor and Three (3) Years for
on-site support. Support should
be available on a 24x7 basis

Comply.
HP P10000 3PAR V400

SAN warranty should include


the following: Three (3) Years
for Parts, Three (3) Years for
Labor and Three (3) Years for
on-site support. Support should
be available on a 24x7 basis

Complying

Proposed Storage Area Network


should have a maximum port
speed of 16GBPS
Should have a minimum of 24
Fibre Channel Ports
Should have a maximum
Aggregate Switch Bandwidth of
768GBPS
No Single Point of Failure

Comply.
HP SN 6000B

Proposed Storage Area Network


should have a maximum port
speed of 16GBPS
Should have a minimum of 24
Fibre Channel Ports
Should have a maximum
Aggregate Switch Bandwidth of
768GBPS
No Single Point of Failure

Complying

Should be able to co-exist with


another Storage Area Network
of the same model and specs for
Hi-Availability
Proposed Storage Area Network
Switch should be able to be
hosted on the Proposed Server
Rack
Should include all Fibre Optics
cable required by the Blade
Servers that will access the
Storage Area Network
Management Software for the
Storage Area Network must be
included
Should not exceed beyond 2U
in height
Proposed Storage Area Network
Switch warranty should include

Complying

Storage Area Network


Switch
Two (2) Units Storage
Area Network Switch

Should be able to co-exist with


another Storage Area Network
of the same model and specs for
Hi-Availability
Proposed Storage Area Network
Switch should be able to be
hosted on the Proposed Server
Rack
Should include all Fibre Optics
cable required by the Blade
Servers that will access the
Storage Area Network
Management Software for the
Storage Area Network must be
included
Should not exceed beyond 2U
in height
Proposed Storage Area Network
Switch warranty should include

Comply.
HP SN 6000B
Comply.
HP SN 6000B
Comply.
HP SN 6000B
Comply.
HP SN 6000B
Comply.
HP SN 6000B
Comply.
HP SN 6000B
Comply.
HP SN 6000B
Comply.
HP SN 6000B
Comply.
HP SN 6000B

Complying
Complying
Complying

Complying

Complying

Complying
Complying
Complying
11

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

the following: Three (3) Years


for Parts, Three (3) Years for
Labor and Three (3) Years for
on-site support. Support should
be available on a 24x7 basis
1.6

1.7

Contract

Information/ Data
Analysis

the following: Three (3) Years


for Parts, Three (3) Years for
Labor and Three (3) Years for
on-site support. Support should
be available on a 24x7 basis

Tape Blade
One (1) Unit Tape
Blade/Drive
Proposed Tape Blade/Drive
should be integrated or external
to the proposed blade server
chassis
Minimum buffer size should be
256MB
Maximum of 1TB/hr Transfer
Rate
Proposed Tape Blade/Drive
should have a minimum of
256Bit Hardware Data
Encryption.
Proposed Tape Blade/Drive
should be able to accommodate
Tapes with 3TB Capacity
Tape Blade warranty should
include the following: Three (3)
Years for Parts, Three (3) Years
for Labor and Three (3) Years
for on-site support. Support
should be available on a 24x7
basis

Comply.
HP Ultrium Tape Blade

Proposed Tapes must be


compatible with the Proposed
Tape Blade/Drive
Proposed Tapes must have a
capacity of 3TB
Proposed Tape should support a

Comply.
HP LTO-5 Ultrium 3TB

Comply.
HP Ultrium Tape Blade
Comply.
HP Ultrium Tape Blade
Comply.
HP Ultrium Tape Blade
Comply.
HP Ultrium Tape Blade
Comply.
HP Ultrium Tape Blade

Proposed Tape Blade/Drive


should be integrated or external
to the proposed blade server
chassis
Minimum buffer size should be
256MB
Maximum of 1TB/hr Transfer
Rate
Proposed Tape Blade/Drive
should have a minimum of
256Bit Hardware Data
Encryption.
Proposed Tape Blade/Drive
should be able to accommodate
Tapes with 3TB Capacity
Tape Blade warranty should
include the following: Three (3)
Years for Parts, Three (3) Years
for Labor and Three (3) Years
for on-site support. Support
should be available on a 24x7
basis

Complying

Proposed Tapes must be


compatible with the Proposed
Tape Blade/Drive
Proposed Tapes must have a
capacity of 3TB
Proposed Tape should support a

Complying

Complying
Complying
Complying

Complying
Complying

Tapes 3 TB
Thirty (30) Unit Tape
Media

Comply.
HP LTO-5 Ultrium 3TB
Comply.

Complying
Complying
12

Item
No.

1.8

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

minimum of 280MB/sec
reading speed
Proposed Tape should have a
maximum of 30 Years Storage
Life
Proposed Tape should support
256Bit Encryption Security

HP LTO-5 Ultrium 3TB

6 RJ-45 autosensing
10/100/1000 port (IEEE 802.3
Type 10BASE-T, IEEE 802.3u
Type 100BASE-TX, IEEE
802.3ab Type 1000BASE-T)
Duplex: 10BASE-T/100BASETX: half or full; 1000BASE-T:
full only
2 slots for network interface
expansion

Comply.
HP MSR 20 Integrated
Services Router

Comply.
HP LTO-5 Ultrium 3TB
Comply.
HP LTO-5 Ultrium 3TB

Contract

minimum of 280MB/sec
reading speed
Proposed Tape should have a
maximum of 30 Years Storage
Life
Proposed Tape should support
256Bit Encryption Security

Information/ Data
Analysis

Complying
Complying

Network Router
Two (2) Units Network
Router

Minimum of 1G SDRAM
Minimum of 800Mbps Firewall
Throughput
Minimum of 500K concurrent
connection
Minimum of 400Mbps 3DES
performance
Minimum of 100Mbps AntiVirus Throughput
Minimum of 100Mbps IPS
Throughput

Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router

6 RJ-45 autosensing
10/100/1000 port (IEEE 802.3
Type 10BASE-T, IEEE 802.3u
Type 100BASE-TX, IEEE
802.3ab Type 1000BASE-T)
Duplex: 10BASE-T/100BASETX: half or full; 1000BASE-T:
full only
2 slots for network interface
expansion

Complying

Minimum of 1G SDRAM

Complying

Minimum of 800Mbps Firewall


Throughput

Complying

Minimum of 500K concurrent


connection

Complying

Minimum of 400Mbps 3DES


performance

Complying

Minimum of 100Mbps AntiVirus Throughput

Complying

Minimum of 100Mbps IPS


Throughput

Complying

Complying

13

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Should support Virtual firewall


Should support Security zone
configuration
Should support Basic and
extended ACLs
Should support MAC-based
access control
Should provide IP Layer 3
filtering based on
source/destination IP
address/subnet and
source/destination TCP/ UDP
port number
Should support IPSec VPN
Should support policy based
routing
Should support HTTP Content
Filtering
Should support NAT
Should support password
encryption
Should support VOIP
Should support T1/E1
connections

Winning Bidders
Specifications

Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router

Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router

Contract

Information/ Data
Analysis

Should support Virtual firewall

Complying

Should support Security zone


configuration

Complying

Should support Basic and


extended ACLs

Complying

Should support MAC-based


access control

Complying

Should provide IP Layer 3


filtering based on
source/destination IP
address/subnet and
source/destination TCP/ UDP
port number
Should support IPSec VPN

Complying

Should support policy based


routing

Complying

Should support HTTP Content


Filtering

Complying

Should support NAT

Complying

Should support password


encryption

Complying

Should support VOIP

Complying

Should support T1/E1


connections

Complying

Complying

14

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Should have redundant power


supply
Should support Virus
definition-based detection
Supporting protocols of HTTP,
FTP, SMTP, and POP3
Preventing virus types of
Backdoor, Email-Worm, IMWorm, P2P-Worm, Trojan,
AdWare, Virus
Supporting virus logs and
reports
Custom-defined URL filtering
library
Supporting Java Blocking and
ActiveX Blocking
Should support L2TP
Should support GRE
Should support Ipv4/v6
Should support ARP
Should support DHCP
relay/server/client
Should support Static routing

Winning Bidders
Specifications

Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated

Contract

Information/ Data
Analysis

Should have redundant power


supply

Complying

Should support Virus


definition-based detection

Complying

Supporting protocols of HTTP,


FTP, SMTP, and POP3

Complying

Preventing virus types of


Backdoor, Email-Worm, IMWorm, P2P-Worm, Trojan,
AdWare, Virus
Supporting virus logs and
reports

Complying

Custom-defined URL filtering


library

Complying

Supporting Java Blocking and


ActiveX Blocking

Complying

Should support L2TP

Complying

Should support GRE

Complying

Should support Ipv4/v6

Complying

Should support ARP

Complying

Should support DHCP


relay/server/client

Complying

Should support Static routing

Complying

Complying

15

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

supports static routes, RIP,


RIPv2, OSPF, and BGP4
Should support IP Multicast
Should be able to handle a
minimum of two (2) ISP and be
able to load balance traffic and
failover traffic from one ISP to
the other in case of ISP Failure
Proposed Network Router
warranty should include the
following: Three (3) Years for
Parts, Three (3) Years for Labor
and Three (3) Years for on-site
support. Support should be
available on a 24x7 basis
1.9

Winning Bidders
Specifications

Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router
Comply.
HP MSR 20 Integrated
Services Router

Contract

Information/ Data
Analysis

supports static routes, RIP,


RIPv2, OSPF, and BGP4

Complying

Should support IP Multicast

Complying

Should be able to handle a


minimum of two (2) ISP and be
able to load balance traffic and
failover traffic from one ISP to
the other in case of ISP Failure
Proposed Network Router
warranty should include the
following: Three (3) Years for
Parts, Three (3) Years for Labor
and Three (3) Years for on-site
support. Support should be
available on a 24x7 basis

Complying

48 RJ-45 auto-sensing 10/100


ports (IEEE 802.3 Type
10Base-T, IEEE Type 100BaseTX); Duplex: half or full
802.3u
4 SFP 1000 Mbps ports

Complying

Minimum Switching Capacity


per Switch: 17.6 Gbps
Minimum Forwarding
Rate/Throughput per Switch:
13.1 Mpps
External redundant power
supply
Minimum of two (2) SFP
1000Base-T Copper
Transceivers per switch

Complying

Complying

Managed Switch
Two (2) Units Managed
Switch
48 RJ-45 auto-sensing 10/100
ports (IEEE 802.3 Type
10Base-T, IEEE Type 100BaseTX); Duplex: half or full
802.3u
4 SFP 1000 Mbps ports
Minimum Switching Capacity
per Switch: 17.6 Gbps
Minimum Forwarding
Rate/Throughput per Switch:
13.1 Mpps
External redundant power
supply
Minimum of two (2) SFP
1000Base-T Copper
Transceivers per switch

Comply.
HP 3610

Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610

Complying

Complying
Complying
Complying

16

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Should support LACP link


aggregation
Should support 4K port-based
VLANs
Should support Mac-based
VLANs
Should support Voice VLAN
Should support GVRP
Should support 32K MAC
addresses
Should support RIP v1/2
Should support OSPF v1/2
Should support BGP
Should support VRRP
Should support RIPng
Should support OSPFv3
BGP4+Should support
Should support VRRP
Should support Routing Policy
Should support IGMP Snooping
Should support IGMP v1/2/3
Should support PIM-DM
Should support PIM-SM
Should support PIM-SSM

Winning Bidders
Specifications

Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.

Contract

Information/ Data
Analysis

Should support LACP link


aggregation
Should support 4K port-based
VLANs
Should support Mac-based
VLANs
Should support Voice VLAN

Complying

Should support GVRP

Complying

Should support 32K MAC


addresses
Should support RIP v1/2

Complying

Should support OSPF v1/2

Complying

Should support BGP

Complying

Should support VRRP

Complying

Should support RIPng

Complying

Should support OSPFv3

Complying

BGP4+Should support

Complying

Should support VRRP

Complying

Should support Routing Policy

Complying

Should support IGMP Snooping

Complying

Should support IGMP v1/2/3

Complying

Should support PIM-DM

Complying

Should support PIM-SM

Complying

Should support PIM-SSM

Complying

Complying
Complying
Complying

Complying

17

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Should support MSDP


Should support MVR, MVR+
Should support MLDv1/2,
MLD Snooping v/1/2
Should support Port traffic
shaping
Should support SP, WRR,
SP+WRR
Should support Flow-based
traffic rate limit
Should support AAA, RADIUS,
and HWTACACS+
Should support SSH2
Should support IEEE 802.1X
Configuration via CLI, Telnet,
and Console port
SNMP vl/2/3, RMON
Web management
Proposed Managed Switch
warranty should include the
following: Three (3) Years for
Parts, Three (3) Years for Labor
and Three (3) Years for on-site
support. Support should be
available on a 24x7 basis
1.11

Winning Bidders
Specifications

HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610
Comply.
HP 3610

Contract

Information/ Data
Analysis

Should support MSDP

Complying

Should support MVR, MVR+

Complying

Should support MLDv1/2,


MLD Snooping v/1/2
Should support Port traffic
shaping
Should support SP, WRR,
SP+WRR
Should support Flow-based
traffic rate limit
Should support AAA, RADIUS,
and HWTACACS+
Should support SSH2

Complying

Should support IEEE 802.1X

Complying

Configuration via CLI, Telnet,


and Console port
SNMP vl/2/3, RMON

Complying

Web management

Complying

Proposed Managed Switch


warranty should include the
following: Three (3) Years for
Parts, Three (3) Years for Labor
and Three (3) Years for on-site
support. Support should be
available on a 24x7 basis

Complying

Proposed Uninterruptible
Power Supply must be able to

Complying

Complying
Complying
Complying
Complying
Complying

Complying

Uninterruptible Power
Supply
Two (2) Units
Uninterruptible Power
Supply
Proposed Uninterruptible
Power Supply must be able to

Comply.
2 units of 10KVA

18

Item
No.

1.12

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

accommodate the power


requirements of the blade server
and storage and network
components stated for at least
30 minutes
Proposed Uninterruptible
Power Supply should be able to
be hosted on the Proposed
Server Rack
Proposed Uninterruptible
Power Supply should be able to
handle the power requirements
of the Blade Servers in the
event that one (1)
Uninterruptible Power Supply
bogs down.
Proposed Uninterruptible
Power Supply must have a
fencing feature that the
Clustering Software may use in
order to fenced an unresponsive
Blade Server
Uninterruptible Power Supply
warranty should include the
following: Three (3) Years for
Parts, Three (3) Years for Labor
and Three (3) Years for on-site
support. Support should be
available on a 24x7 basis

Emerson

Should be at least Intel Core i7


or equivalent with 2.0 GHZ
processor speed, 4 GB RAM,
500 GB SATA HDD, 256MB
Video RAM, Gigabit Ethernet,
300 W power supply,
Keyboard, Mouse

Comply.
HP Pavilion p7qe series

Comply.
2 units of 10KVA
Emerson
Comply.
2 units of 10KVA
Emerson

Comply.
2 units of 10KVA
Emerson

Comply.
2 units of 10KVA
Emerson

Contract

accommodate the power


requirements of the blade server
and storage and network
components stated for at least
30 minutes
Proposed Uninterruptible
Power Supply should be able to
be hosted on the Proposed
Server Rack
Proposed Uninterruptible
Power Supply should be able to
handle the power requirements
of the Blade Servers in the
event that one (1)
Uninterruptible Power Supply
bogs down.
Proposed Uninterruptible
Power Supply must have a
fencing feature that the
Clustering Software may use in
order to fenced an unresponsive
Blade Server
Uninterruptible Power Supply
warranty should include the
following: Three (3) Years for
Parts, Three (3) Years for Labor
and Three (3) Years for on-site
support. Support should be
available on a 24x7 basis

Information/ Data
Analysis

Complying

Complying

Complying

Complying

Client Workstations
Desktop
Ten (10) Units Client
Workstation - Desktop
Should be at least Intel Core i7
or equivalent with 2.0 GHZ
processor speed, 4 GB RAM,
500 GB SATA HDD, 256MB
Video RAM, Gigabit Ethernet,
300 W power supply,
Keyboard, Mouse

Complying

19

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Windows 7 professional 64-bit


17 LED Display
At least 500W UPS with 30
minute backup time
Client workstation warranty
should include the following:
Three (3) Years for Parts, Three
(3) years for labor and Three (3)
years for on-site support.
1.13

Winning Bidders
Specifications

Contract

Information/ Data
Analysis

Comply.
HP Pavilion p7qe series
Comply.
HP Pavilion p7qe series
Comply.
HP Pavilion p7qe series
Comply.
HP Pavilion p7qe series

Windows 7 professional 64-bit

Complying

17 LED Display

Complying

At least 500W UPS with 30


minute backup time
Client workstation warranty
should include the following:
Three (3) Years for Parts, Three
(3) years for labor and Three (3)
years for on-site support.

Complying

Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook

OS X Lion

Complying

2.0Ghz Quad-core Intel Core i7


GMB Shared L3 Cache

Complying

4GB 1333MHz DDR3 SDRAM


- 2x4GB

Complying

500GB Serial ATA Drive @


5400 rpm

Complying

SuperDrive 8x (DVDR DL/


DVDRW/CD-RW)

Complying

Backlit Keyboard (English) &


User's Guide

Complying

Built-in 77.5 watt-hour lithiumpolymer battery up to 7 hours


batter power
Wifi Wireless networking 2 on
IEEE 802.11n specification;

Complying

Complying

Client Workstations
Laptop
Four (4) Units Client
High-End Business
Intelligence Laptop
OS X Lion
2.0Ghz Quad-core Intel Core i7
GMB Shared L3 Cache
4GB 1333MHz DDR3 SDRAM
- 2x4GB
500GB Serial ATA Drive @
5400 rpm
SuperDrive 8x (DVDR DL/
DVDRW/CD-RW)
Backlit Keyboard (English) &
User's Guide
Built-in 77.5 watt-hour lithiumpolymer battery up to 7 hours
batter power
Wifi Wireless networking 2 on
IEEE 802.11n specification;

Complying
20

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

802.11a/b/g compatible
Bluetooth 2.1 + EDR
10/100/1000 Base-T Gigabit
Ethernet
Full-size backlit keyboard
Multi-touch track pad
Client workstation warranty
should include the following:
Three (3) Years for Parts, Three
(3) years for labor and Three (3)
years for on-site
1.14

Winning Bidders
Specifications

Contract

Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro
Comply.
Apple 15-inch MacBook
Pro

802.11a/b/g compatible
Bluetooth 2.1 + EDR

Comply.
Apple iPad2 Wifi+ 3G
Comply.
Apple iPad2 Wifi+ 3G
Comply.
Apple iPad2 Wifi+ 3G
Comply.
Apple iPad2 Wifi+ 3G
Comply.
Apple iPad2 Wifi+ 3G
Comply.
Apple iPad2 Wifi+ 3G

Information/ Data
Analysis

Complying

10/100/1000 Base-T Gigabit


Ethernet

Complying

Full-size backlit keyboard

Complying

Multi-touch track pad

Complying

Client workstation warranty


should include the following:
Three (3) Years for Parts, Three
(3) years for labor and Three (3)
years for on-site

Complying

IOS 5

Complying

Maximum of 10" LED Display

Complying

Memory: 64GB

Complying

Dimension: not more than


9.5inx7.31inx0.34in
Weight : not more than 1.35 lbs

Complying

Wi-Fi +3G model:


UMTS/HSDPA/HSUPA (850,
900, 1900, 2100 MHz):
GSM/EDGE (850, 900, 1800,
1900 MHz)
WiFi (802.11 a/b/g/n)

Complying

Tablet
Five (5) Units Client
High-End Executive
Decision Support Tablet
IOS 5
Maximum of 10" LED Display
Memory: 64GB
Dimension: not more than
9.5inx7.31inx0.34in
Weight : not more than 1.35 lbs
Wi-Fi +3G model:
UMTS/HSDPA/HSUPA (850,
900, 1900, 2100 MHz):
GSM/EDGE (850, 900, 1800,
1900 MHz)
WiFi (802.11 a/b/g/n)

Comply.
Apple iPad2 Wifi+ 3G

Complying

Complying
21

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Bluetooth 2.1 + EDR


technology
1GHz dual-core, highperformance, low-power
system-on-a-chip
Three-axis gyro, accelerometer,
ambient light sensor
Micro-SIM card tray
Smart Cover
Tablet warranty should include
a minimum of 1 Year Warranty
1.15

Comply.
Apple iPad2 Wifi+ 3G
Comply.
Apple iPad2 Wifi+ 3G
Comply.
Apple iPad2 Wifi+ 3G
Comply.
Apple iPad2 Wifi+ 3G
Comply.
Apple iPad2 Wifi+ 3G
Comply.

Contract

Information/ Data
Analysis

Bluetooth 2.1 + EDR


technology
1GHz dual-core, highperformance, low-power
system-on-a-chip
Three-axis gyro, accelerometer,
ambient light sensor
Micro-SIM card tray

Complying

Smart Cover

Complying

Tablet warranty should include


a minimum of 1 Year Warranty

Complying

Laser printer

Complying

Can provide colored and black


output

Complying

Minimum of 18 page per


minute

Complying

Minimum of 128MB Internal


Memory

Complying

Automatic Duplex printing

Complying

Mobile Printing Capability

Complying

Hi-Speed USB 2.0: 1 Ethernet

Complying

Complying
Complying
Complying

Network Printer
Two (2) Units Network
Printer
Laser printer
Can provide colored and black
output
Minimum of 18 page per
minute
Minimum of 128MB Internal
Memory
Automatic Duplex printing
Mobile Printing Capability
Hi-Speed USB 2.0: 1 Ethernet

1.16

Winning Bidders
Specifications

Comply.
HP CLJ CP2025DN
PN: CB495A
Comply.
HP CLJ CP2025DN
PN: CB495A
Comply.
HP CLJ CP2025DN
PN: CB495A
Comply.
HP CLJ CP2025DN
PN: CB495A
Comply.
HP CLJ CP2025DN
PN: CB495A
Comply.
HP CLJ CP2025DN
PN: CB495A
Comply.
HP CLJ CP2025DN
PN: CB495A

Scanner
Two (2) Units Scanner
22

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Flatbed scanner type


Up to 4800 dpi
Maximum scan size 216 x 311
mm
Media Types: Paper (plain,
inkjet, photo, banner),
envelopes, labels, cards (index,
greeting), 3-D objects, 35 mm
slides and negatives (using
transparent materials adapter),
iron-on transfers
Scan File Format: Windows:
BMP, JPEG, TIFF, TIFF
compressed, PNG, PCX,
Flashpix (FPX), PDF, PDF
searchable, RTF, HTM, TXT;
Macintosh: TIFF, PICT, JPEG,
GIF, FlashPix. Plain Text, PDF,
HTML, Rich Text
Connectivity: USB 2.0
1.17

Comply.
HP ScanJet G3110
PN: L2698A
Comply.
HP ScanJet G3110
PN: L2698A
Comply.
HP ScanJet G3110
PN: L2698A
Comply.
HP ScanJet G3110
PN: L2698A

Comply.
HP ScanJet G3110
PN: L2698A

Comply.
HP ScanJet G3110
PN: L2698A

Contract

Information/ Data
Analysis

Flatbed scanner type

Complying

Up to 4800 dpi

Complying

Maximum scan size 216 x 311


mm

Complying

Media Types: Paper (plain,


inkjet, photo, banner),
envelopes, labels, cards (index,
greeting), 3-D objects, 35 mm
slides and negatives (using
transparent materials adapter),
iron-on transfers
Scan File Format: Windows:
BMP, JPEG, TIFF, TIFF
compressed, PNG, PCX,
Flashpix (FPX), PDF, PDF
searchable, RTF, HTM, TXT;
Macintosh: TIFF, PICT, JPEG,
GIF, FlashPix. Plain Text, PDF,
HTML, Rich Text
Connectivity: USB 2.0

Complying

Minimum Contrast of 4500:1

Complying

Minimum Lumens of 3000

Complying

Minimum Resolution 1024x768

Complying

With Installation and


configuration

Complying

Complying

Complying

Projector
Two (2) Units Projector
Minimum Contrast of 4500:1
Minimum Lumens of 3000
Minimum Resolution 1024x768
With Installation and
configuration

1.18

Winning Bidders
Specifications

Comply.
Acer S 5201M projector
Comply.
Acer S 5201M projector
Comply.
Acer S 5201M projector
Comply.
Acer S 5201M projector

Projector Screen
(Motorized)
23

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Contract

Information/ Data
Analysis

One (1) Unit Projector


Screen
Motorized Screen
Minimum of 90
Remote Controlled
With Installation and
configuration
1.19

Comply.
EZ Screen Motorized
Screen Projector
Comply.
EZ Screen Motorized
Screen Projector
Comply.
EZ Screen Motorized
Screen Projector
Comply.
EZ Screen Motorized
Screen Projector

Motorized Screen

Complying

Minimum of 90

Complying

Remote Controlled

Complying

With Installation and


configuration

Complying

Proxy Appliance
Two (2) Unit Proxy
Appliance
One (1) unit Web Filter
(Proxy SG)
One (1) unit Anti virus (Proxy
AV)
Web 2.0 Threat protection

Real-time web content ratings


On-demand cloud intelligence
Web 2.0 mashed up content
filtering
Inline threat analysis (five AV
choices)
Social networking threat
protection
True file type checks
Compressed archive analysis
File and attachment filtering
Hardware-based SSL

Agencys technical
specifications are
incomplete and does
not coincide with the
winning bidders
technical specs.
-do-do-do-do-do-do-do-do-do24

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Contract

performance
Data loss prevention integration
Proxy avoidance blocking
Web application and operation
controls
Protocol method controls
Bandwidth management
Media stream splitting and
caching
Acceleration and optimization
Transparent or Explicit
deployment
Full IPV6 implementation
IPV4 to IPV6 migration
IPV6 advance policy
management
License Capacity 400
Employee Count
Disk drives 1x250 GB SATA
4GB RAM
Rack-mountable appliance
Proxy Appliance should include
the following: Three (3) Years
for Parts, Three (3) Years for
Labor, and Three (3) Years
License/Subscription on
Appliance Software and
Modules included and Three (3)
Years for on-site Support
should be available on a 24x7
basis
2.0

Information/ Data
Analysis

-do-do-do-do-do-do-do-do-do-do-do-do-do-do-do-do-

Software
Operating System
Fifteen (15) Units
Enterprise Linux
Operating System
All Blade Servers except the
Backup Server should include
Enterprise Linux as it's

Comply.
SuSE Enterprise Linux
OS

All Blade Servers except the


Backup Server should include
Enterprise Linux as it's

Complying

25

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Operating System
Enterprise Linux must include a
Vendor Support, and must be
officially certified by hardware
vendor
Enterprise Linux Support must
be available via Phone, Mail
and On-Site on a 24x7 basis
Enterprise Linux Support
Subscription must include
software updates, Bug Fixes,
Security Fixes, Web Tickets
Enterprise Linux should support
32Bit and 64Bit Hardware
Architecture
Enterprise Linux should have
official support for clustered
file system including OCFS2
Should support 2.6.32 Kernel
Version or higher
Enterprise Linux Support
Subscription must be available
on a 24x7 basis for three (3)
years
DVD and CD installer of the
Enterprise Linux must be
provided

Winning Bidders
Specifications

Comply.
SuSE Enterprise Linux
OS
Comply.
SuSE Enterprise Linux
OS
Comply.
SuSE Enterprise Linux
OS
Comply.
SuSE Enterprise Linux
OS
Comply.
SuSE Enterprise Linux
OS
Comply.
SuSE Enterprise Linux
OS
Comply.
SuSE Enterprise Linux
OS
Comply.
SuSE Enterprise Linux
OS

Contract

Operating System
Enterprise Linux must include a
Vendor Support, and must be
officially certified by hardware
vendor
Enterprise Linux Support must
be available via Phone, Mail
and On-Site on a 24x7 basis
Enterprise Linux Support
Subscription must include
software updates, Bug Fixes,
Security Fixes, Web Tickets
Enterprise Linux should support
32Bit and 64Bit Hardware
Architecture
Enterprise Linux should have
official support for clustered
file system including OCFS2
Should support 2.6.32 Kernel
Version or higher

Information/ Data
Analysis

Complying

Complying
Complying

Complying
Complying
Complying

Enterprise Linux Support


Subscription must be available
on a 24x7 basis for three (3)
years
DVD and CD installer of the
Enterprise Linux must be
provided

Complying

Backup Server should support


Microsoft Windows 2008 R2
Server edition as its Operating
System
Microsoft Windows 2008 R2
Server Support must be
available via Phone, Mail and
On-site

Complying

Complying

One (1) Unit Microsoft


Windows 2008 R2 Server
Edition
Backup Server should support
Microsoft Windows 2008 R2
Server edition as its Operating
System
Microsoft Windows 2008 R2
Server Support must be
available via Phone, Mail and
On-site

Comply.
MS Windows 2008 R2
Comply.
MS Windows 2008 R2

Complying

26

Item
No.

2.1

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Microsoft Windows 2008 R2


Server should support 32Bit
and 64Bit Hardware
Architecture
Microsoft Windows 2008 R2
Server Support must be
available on a 24x7 basis for
three (3) years

Comply.
MS Windows 2008 R2

The system should be capable


of on-demand querying. Report
generated subsequently should
be intuitive and easy to use for
end-users to understand and
use.
End-user tools should be
capable of providing extremely
quick response times to their
end-users.
Multi-dimensional analysis (i.e.
Slicing and dicing of data)
should be available. Drill-down,
drill up and drill cross
capability should also be
included.
Pivot and cross-tabs is
supported. Should allow endusers to swing attributes
between pages, rows and
columns.
System should support a multipass query in which an initial
query obtains a subset of data
that is fed to a second, more
complex query.
Allows end-users and

Comply.
Vanilla Business
Intelligence Suite

Comply.
MS Windows 2008 R2

Contract

Information/ Data
Analysis

Microsoft Windows 2008 R2


Server should support 32Bit
and 64Bit Hardware
Architecture
Microsoft Windows 2008 R2
Server Support must be
available on a 24x7 basis for
three (3) years

Complying

The system should be capable


of on-demand querying. Report
generated subsequently should
be intuitive and easy to use for
end-users to understand and
use.
End-user tools should be
capable of providing extremely
quick response times to their
end-users.
Multi-dimensional analysis (i.e.
Slicing and dicing of data)
should be available. Drill-down,
drill up and drill cross
capability should also be
included.
Pivot and cross-tabs is
supported. Should allow endusers to swing attributes
between pages, rows and
columns.
System should support a multipass query in which an initial
query obtains a subset of data
that is fed to a second, more
complex query.
Allows end-users and

Complying

Complying

Business Intelligence
Software
Unlimited User License Business Intelligence
Software

Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite

Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.

Complying

Complying

Complying

Complying

Complying
27

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

administrators to provide
criteria to suppress/hide rows or
sections of a generated report.
As an example, output rows be
automatically suppressed if all
data points are zero. A subset of
data be pulled but only show
part of the subset
Capable of handling missing or
"null" data points. Missing data
can be displayed to the enduser. End-users can supply their
own text alternative
Should be able to access to
relational and/or OLAP data
sources.
Capable of calculating and
displaying percentage or unit
change between values on the
same row in different columns
(e.g. Increase/decrease in
budget allocation from one year
to the next)
A built-in functions (e.g. Text,
date, numeric, comparison,
logical, etc.) is available for
end-user to use.
Supports graphical type views
and output (e.g. Pie, charts, line
graphs, etc.) Also such graphs
may be customized by endusers. Re-angling (3D),
preparing a print ready graph,
specifying a legend, title, axis.
Fonts, color schemes, etc.
Supports drill down directly via
the graphical display by the
end-user (e.g. Click on a wedge
of a chart to obtain detailed
information)

Winning Bidders
Specifications

Vanilla Business
Intelligence Suite

Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite

Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite

Comply.
Vanilla Business
Intelligence Suite

Contract

administrators to provide
criteria to suppress/hide rows or
sections of a generated report.
As an example, output rows be
automatically suppressed if all
data points are zero. A subset of
data be pulled but only show
part of the subset
Capable of handling missing or
"null" data points. Missing data
can be displayed to the enduser. End-users can supply their
own text alternative
Should be able to access to
relational and/or OLAP data
sources.
Capable of calculating and
displaying percentage or unit
change between values on the
same row in different columns
(e.g. Increase/decrease in
budget allocation from one year
to the next)
A built-in functions (e.g. Text,
date, numeric, comparison,
logical, etc.) is available for
end-user to use.
Supports graphical type views
and output (e.g. Pie, charts, line
graphs, etc.) Also such graphs
may be customized by endusers. Re-angling (3D),
preparing a print ready graph,
specifying a legend, title, axis.
Fonts, color schemes, etc.
Supports drill down directly via
the graphical display by the
end-user (e.g. Click on a wedge
of a chart to obtain detailed
information)

Information/ Data
Analysis

Complying

Complying
Complying

Complying

Complying

Complying

28

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Allows end-user to toggle


between flat data-only view and
a graphical view
Allows end-users to preview a
report by limiting output to the
first 100 rows from relational
data source and from an OLA.P
source.
Allows query/report output be
saved as a snapshot for future
use. Can be sent as a mail
attachment, or exported to other
applications
Allows end-users to work with
data offline (e.g. While on
laptop off the network)
Allows end-users to view report
configuration details, including
filters, hidden sections while
viewing the report output.
All systems and tools should be
incorporated and integrated
(e.g. Microsoft Excel and
Access, Oracle RDBMS, SQL
Server, DB2, MySQL,
standalone reports, flat files,
XML, etc.)
Capable of supporting BI Portal
to provide web-based graphical
user interface with a business
intelligence package, allowing
access according to user
specific needs and
authorizations.
A script should be able to
control ETL Software in terms
of technical aspects such as
programming language used
and software.
Should be capable of automated

Winning Bidders
Specifications

Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite

Comply.
Vanilla Business
Intelligence Suite

Comply.
Vanilla Business
Intelligence Suite
Comply.

Contract

Allows end-user to toggle


between flat data-only view and
a graphical view
Allows end-users to preview a
report by limiting output to the
first 100 rows from relational
data source and from an OLA.P
source.
Allows query/report output be
saved as a snapshot for future
use. Can be sent as a mail
attachment, or exported to other
applications
Allows end-users to work with
data offline (e.g. While on
laptop off the network)
Allows end-users to view report
configuration details, including
filters, hidden sections while
viewing the report output.
All systems and tools should be
incorporated and integrated
(e.g. Microsoft Excel and
Access, Oracle RDBMS, SQL
Server, DB2, MySQL,
standalone reports, flat files,
XML, etc.)
Capable of supporting BI Portal
to provide web-based graphical
user interface with a business
intelligence package, allowing
access according to user
specific needs and
authorizations.
A script should be able to
control ETL Software in terms
of technical aspects such as
programming language used
and software.
Should be capable of automated

Information/ Data
Analysis

Complying
Complying

Complying

Complying
Complying

Complying

Complying

Complying

Complying
29

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

historic data loads, incremental


loads, aggregate and OLAP
processing.
ETL tools SHOULD have builtin facilities for data quality
identification, surrogate key
creation and other common
housekeeping procedures.
Data is normalized in the Data
Store or the Dimensional Data
Modeling.
System Documentation should
include ETL Specifications.
Support different data formats
(e.g. CSV, Microsoft Excel,
XML, HTML, etc)
Outside data sources, including
spreadsheets, transactional
databases, relational databases
and flat files can be integrated
into the DW and BI Platform.
Capable of displaying
organized report menu
Has the capability to provide
access to underlying metadata
from within the Business
Intelligence tool
End-users can bookmark data
for later perusal.
End-user environment allow the
creation of hyperlinks to
external web pages. Supports
the search utilities that are
available within the end-user
client.
Business Intelligence system

Winning Bidders
Specifications

Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite

Comply.

Contract

historic data loads, incremental


loads, aggregate and OLAP
processing.
ETL tools SHOULD have builtin facilities for data quality
identification, surrogate key
creation and other common
housekeeping procedures.
Data is normalized in the Data
Store or the Dimensional Data
Modeling.
System Documentation should
include ETL Specifications.

Information/ Data
Analysis

Complying

Complying
Complying

Support different data formats


(e.g. CSV, Microsoft Excel,
XML, HTML, etc)
Outside data sources, including
spreadsheets, transactional
databases, relational databases
and flat files can be integrated
into the DW and BI Platform.
Capable of displaying
organized report menu

Complying

Has the capability to provide


access to underlying metadata
from within the Business
Intelligence tool
End-users can bookmark data
for later perusal.

Complying

End-user environment allow the


creation of hyperlinks to
external web pages. Supports
the search utilities that are
available within the end-user
client.
Business Intelligence system

Complying

Complying

Complying

Complying

Complying
30

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

should provide common used


standardized application
templates.
Business Intelligence system
should provide an Application
Development and Naming
Standard documentation
Support Data Cubes. The multidimensional Data Cubes are
formed and OLAP engine and
its functions in terms of load,
manage and retrieve Cubes.
Business Intelligence tool is
capable on providing Data
Mining.
Platform and System
Requirements is available on
the system documentation
Web user interface is available
on widely used internet
browsers such us Internet
Explorer, Firefox etc for webbased clients
The overall architecture is
available based on system and
software requirements (e.g.
client/server, two-tier/three-tier
architecture, etc)
The system should provide
notification to the users
whenever a new software
upgrade is released and is free
of charge
Development of the system
which includes Physical Data
Warehouse structure design,
used disk space and how keys
are constructed and used is
properly documented.

Winning Bidders
Specifications

Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite

Contract

should provide common used


standardized application
templates.
Business Intelligence system
should provide an Application
Development and Naming
Standard documentation
Support Data Cubes. The multidimensional Data Cubes are
formed and OLAP engine and
its functions in terms of load,
manage and retrieve Cubes.
Business Intelligence tool is
capable on providing Data
Mining.
Platform and System
Requirements is available on
the system documentation
Web user interface is available
on widely used internet
browsers such us Internet
Explorer, Firefox etc for webbased clients
The overall architecture is
available based on system and
software requirements (e.g.
client/server, two-tier/three-tier
architecture, etc)
The system should provide
notification to the users
whenever a new software
upgrade is released and is free
of charge
Development of the system
which includes Physical Data
Warehouse structure design,
used disk space and how keys
are constructed and used is
properly documented.
In anticipation of expanding

Information/ Data
Analysis

Complying

Complying

Complying
Complying
Complying

Complying

Complying

Complying

Not specifically
31

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Dimensional Data Model


handles changes in dimensions
without disruptions to any
related aggregations.
Reports and data are protected
from unauthorized users via
security policy
Security policies applied to
Web-base Clients are different
to those applied to Standalone
Clients
Firewall configuration is
flexible and can adjust to
changes on the security
architecture
Access to users through the
website is authorized and
controlled
Allows Data Warehouse
security profile in setting up
and maintaining sign-on ID and
password types such as add,
delete or modify data are
managed in the Data Warehouse
and BI Platform.
The design/development
environment is intuitive and
easy for users to understand and
use
Supports the use of a
proprietary development
language/script

Winning Bidders
Specifications

Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite

Comply.
Vanilla Business
Intelligence Suite
Comply.
Vanilla Business
Intelligence Suite

Contract

Data Warehouse, particularly


indexes and aggregations, has
method of database partitions or
using multiple disk controllers
to reduce I/O bottlenecks is part
Dimensional Data Model
handles changes in dimensions
without disruptions to any
related aggregations.
Reports and data are protected
from unauthorized users via
security policy
Security policies applied to
Web-base Clients are different
to those applied to Standalone
Clients
Firewall configuration is
flexible and can adjust to
changes on the security
architecture
Access to users through the
website is authorized and
controlled
Allows Data Warehouse
security profile in setting up
and maintaining sign-on ID and
password types such as add,
delete or modify data are
managed in the Data Warehouse
and BI Platform.
The design/development
environment is intuitive and
easy for users to understand and
use
Supports the use of a
proprietary development Media
stream splitting and caching
Support version control to
maintain a history of changes
through the development

Information/ Data
Analysis

stated in the agencys


required technical
specifications but
being offered by the
winning bidder.
Complying

Complying
Complying

Complying

Complying
Complying

Complying

Complying
Agencys technical
specifications are
incomplete and does
32

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Contract

environment
Support debugging capabilities
Flexibility to the developer in
directing the placement of
output objects on the report.
End-users require web-based,
as well as print-ready reports.
Non-data objects can be added
to reports (e.g. text, graphics,
hyperlinks to related
information or other reports)
A SQL or other query language
output can automatically be
generated.
Developers can easily edit or
write their own custom SQL
statements
Developers should be able to
call external stored procedures
or other external functions
Customized data columns can
be added
Enforce levels of edit access
control
Level of data normalization
should be available in the
Business Intelligence and Data
Warehouse platform
Ability to migrate Business
Intelligence and Data
Warehouse software from
Development Environment to
Production Environment
Software should be open source
with 3 years commercial
support
2.2

Information/ Data
Analysis

not coincide with the


winning bidders
technical specs.
-do-do-

-do-

-do-do-do-do-do-do-

-do-

-do-

Database License
33

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Minimum of Fifty (50) units


named user license depending
to the server processor
specification.
Should be a standard RDBMS
adhering to ANSI standards.
DW platform should be
compatible with all leading BI
applications and ETL tools for
access through ODBC/JDBC
interfaces.
Can hold textual and numerical
data, graphical information and
animations.
Capable of receiving and
storing coded-decoded data
types from different data
sources.
Has the ability to synchronize
data with heterogeneous
databases
Provides proactive database
diagnostics in graphical and
text format
Wizard driven database tuning
tools to identify and help
rectify performance
bottlenecks
Web-based tuning/diagnostic
tools fully integrated to the
database management tool
Capability to logically partition
tables/indexes for ease of
maintenance and for
performance improvements
Has an option to use "in-

Comply. Oracle Database


EE

Contract

Information/ Data
Analysis

Fifty (50) Units Named


User Perpetual License
-Database Software

Comply. Oracle Database


EE

Comply. Oracle Database


EE
Comply. Oracle Database
EE
Comply. Oracle Database
EE
Comply. Oracle Database
EE
Comply. Oracle Database
EE
Comply. Oracle Database
EE
Comply. Oracle Database
EE
Comply. Oracle Database

Minimum of Fifty (50) units


named user license depending
to the server processor
specification.
Should be a standard RDBMS
adhering to ANSI standards.
DW platform should be
compatible with all leading BI
applications and ETL tools for
access through ODBC/JDBC
interfaces.
Can hold textual and numerical
data, graphical information and
animations.
Capable of receiving and
storing coded-decoded data
types from different data
sources.
Has the ability to synchronize
data with heterogeneous
databases
Provides proactive database
diagnostics in graphical and
text format
Wizard driven database tuning
tools to identify and help
rectify performance
bottlenecks
Web-based tuning/diagnostic
tools fully integrated to the
database management tool
Capability to logically partition
tables/indexes for ease of
maintenance and for
performance improvements
Has an option to use "in-

Complying

Complying

Complying
Complying

Complying
Complying
Complying

Complying
Complying

Complying
34

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

database" data mining functions


Supports referential integrity

EE
Comply. Oracle Database
EE
Comply. Oracle Database
EE

Has a native support for


advanced analytical functions
for use in business intelligence.
Should support bitmap indexes.
Built-in multi-dimensional
OLAP capabilities
Developers should be able to
call external stored procedures
or other external functions.
In anticipation of expanding
Data Warehouse, particularly
indexes and aggregations, has
method of database partitions or
using multiple disk controllers
to reduce I/0 bottlenecks is part
of the design considerations
2.3

Comply. Oracle Database


EE
Comply. Oracle Database
EE
Comply. Oracle Database
EE
Comply. Oracle Database
EE

Contract

database" data mining functions


Supports referential integrity

Information/ Data
Analysis

Complying

Has a native support for


advanced analytical functions
for use in business intelligence.
Should support bitmap indexes.

Complying

Built-in multi-dimensional
OLAP capabilities
Developers should be able to
call external stored procedures
or other external functions.
In anticipation of expanding
Data Warehouse, particularly
indexes and aggregations, has
method of database partitions or
using multiple disk controllers
to reduce I/0 bottlenecks is part
of the design considerations

Complying

Should be able to backup entire


disk image of servers and
desktops
Should be able to perform a full
system backup
Should be able to perform file
level backup
Should be able to perform hot
backup
Should be able to perform cold
backup

Complying

Complying

Complying
Complying

System Backup and Restore


License
Sixteen (16) Units
Licenses for Server and
Fourteen (14) Units
Licenses for Workstation System Backup and
Recovery Software
Should be able to backup entire
disk image of servers and
desktops
Should be able to perform a full
system backup
Should be able to perform file
level backup
Should be able to perform hot
backup
Should be able to perform cold
backup

Comply. Acronis Backup


& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11

Complying
Complying
Complying
Complying
35

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Should he able to backup both


Linux and Windows machines
Should be able to perform
schedule backups
Should be able to perform
backup validation
Should be able to perform Data
De-duplication
Should be able to implement
encryption on the backup image
file
Should be able to store backup
images via Storage Area
Network
Should be able to manage tape
drive
Should be able to store backup
images via Tape
Should have a centralized
backup management.
Should be capable of Agentbased management of servers to
be backed up
Should be able to conduct bare
metal restoration
Should be able to restore
backup images from Storage
Area Network backup image
repository
Should be able to restore
backup images from Tape
Should be able to restore
backup images to a dissimilar
machine from the backup
source
Should be able to perform full
system recovery
Should be able to support 32Bit
and 64Bit hardware

Comply. Acronis Backup


& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11
Comply. Acronis Backup
& Recovery 11

Contract

Should he able to backup both


Linux and Windows machines
Should be able to perform
schedule backups
Should be able to perform
backup validation
Should be able to perform Data
De-duplication
Should be able to implement
encryption on the backup image
file
Should be able to store backup
images via Storage Area
Network
Should be able to manage tape
drive
Should be able to store backup
images via Tape
Should have a centralized
backup management.
Should be capable of Agentbased management of servers to
be backed up
Should be able to conduct bare
metal restoration
Should be able to restore
backup images from Storage
Area Network backup image
repository
Should be able to restore
backup images from Tape
Should be able to restore
backup images to a dissimilar
machine from the backup
source
Should be able to perform full
system recovery
Should be able to support 32Bit
and 64Bit hardware

Information/ Data
Analysis

Complying
Complying
Complying
Complying
Complying
Complying
Complying
Complying
Complying
Complying
Complying
Complying

Complying
Complying

Complying
Complying
36

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

architecture
Should support the following
operating system: Windows 7 /
Vista / XP / 2000Pro Windows
Server 2008 R1 and R2
Windows Server 2003 R1 and
R2 Windows Server 2000
Enterprise Linux
Total of Thirty (30) Licenses
should be provided. Licenses
must be comprised of sixteen
(16) Licenses for Server and
fourteen (14) Licenses for
Desktops
System Backup and Restore
software should include the
following: Three (3) Years
License and three (3) Years for
on-site support. Support should
be available on a 24x7 basis
2.4

Winning Bidders
Specifications

Comply. Acronis Backup


& Recovery 11

Comply. Acronis Backup


& Recovery 11

Comply. Acronis Backup


& Recovery 11

Contract

architecture
Should support the following
operating system: Windows 7 /
Vista / XP / 2000Pro Windows
Server 2008 R1 and R2
Windows Server 2003 R1 and
R2 Windows Server 2000
Enterprise Linux
Total of Thirty (30) Licenses
should be provided. Licenses
must be comprised of sixteen
(16) Licenses for Server and
fourteen (14) Licenses for
Desktops
System Backup and Restore
software should include the
following: Three (3) Years
License and three (3) Years for
on-site support. Support should
be available on a 24x7 basis

Information/ Data
Analysis

Complying

Complying

Complying

Security Information and


Events Management
License
Two (2) Units Processor
License - System
Information and Events
Management Software
Processor based licensing
Software license must be
compatible to the Blade
Servers
Should provide Vendor support
and certification on the
Operating System and
Hardware
Enterprise Linux Support must
be available via Phone, Mail
and On-Site

Comply
Sentinel SIEM
Comply
Sentinel SIEM
Comply
Sentinel SIEM
Comply
Sentinel SIEM

Processor based licensing

Complying

Software license must be


compatible to the Blade
Servers
Should provide Vendor support
and certification on the
Operating System and
Hardware
Enterprise Linux Support must
be available via Phone, Mail
and On-Site

Complying
Complying

Complying

37

Item
No.

2.5

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

License must include software


updates, Bug Fixes, Security
Fixes, Web Tickets
Software should support 32Bit
and 64Bit Hardware
Architecture
Mitigate security threats with
real-time actionable intelligence
Detect threats quickly with
automated compliance
monitoring
Connect and correlate security
event data in a single dashboard
Simplify compliance with
policy enforcement
Get real-time reporting so you
can take immediate action
Should support Enterprise
Linux with 2.6 Kernel level and
Microsoft Server 2003 and
2008
Should support Mozilla Firefox
and Internet Explorer Browsers
Should support the following
RDBMS: Oracle and Microsoft

Comply
Sentinel SIEM

Corporate Lifetime License

Comply. Teamviewer for


Remote Desktop
Software
Comply. Teamviewer for
Remote Desktop
Software
Comply. Teamviewer for
Remote Desktop
Software
Comply. Teamviewer for
Remote Desktop

Comply
Sentinel SIEM
Comply
Sentinel SIEM
Comply
Sentinel SIEM
Comply
Sentinel SIEM
Comply
Sentinel SIEM
Comply
Sentinel SIEM
Comply
Sentinel SIEM
Comply
Sentinel SIEM
Comply
Sentinel SIEM

Contract

Information/ Data
Analysis

License must include software


updates, Bug Fixes, Security
Fixes, Web Tickets
Software should support 32Bit
and 64Bit Hardware
Architecture
Mitigate security threats with
real-time actionable intelligence
Detect threats quickly with
automated compliance
monitoring
Connect and correlate security
event data in a single dashboard
Simplify compliance with
policy enforcement
Get real-time reporting so you
can take immediate action
Should support Enterprise
Linux with 2.6 Kernel level and
Microsoft Server 2003 and
2008
Should support Mozilla Firefox
and Internet Explorer Browsers
Should support the following
RDBMS: Oracle and Microsoft

Complying

Corporate Lifetime License

Complying

Compatible with Linux and


Windows Operating System
and OSX
Compatible with Tablet form
factor

Complying

Unlimited number of hosts

Complying

Complying
Complying
Complying
Complying
Complying
Complying
Complying

Complying
Complying

Remote Desktop Software


Unlimited Licenses for
Remote Desktop Software

Compatible with Linux and


Windows Operating System
and OSX
Compatible with Tablet form
factor
Unlimited number of hosts

Complying

38

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Multi-platform Support
Supports VOIP, Video, Chat,
Conference as means of
communication
Supports multiple language
Minimum of 1Year Technical
Support from Vendor
3.0
3.1

Services
System Integration

3.2
3.3
3.4
3.5
3.6

Software Implementation
Reports Implementation
Data Migration Services
Maintenance Services
Security Information and
Events Management
Vulnerability Assessment
Training
Strategic Planning for
Business Intelligence
Workshop Training
Twenty (20) Pax for
Strategic Planning for
Business Intelligence
Training Workshop

3.7
4.0
4.1

Winning Bidders
Specifications

Software
Comply. Teamviewer for
Remote Desktop
Software
Comply. Teamviewer for
Remote Desktop
Software
Comply. Teamviewer for
Remote Desktop
Software
Comply. Teamviewer for
Remote Desktop
Software

Contract

Information/ Data
Analysis

Multi-platform Support

Complying

Supports VOIP, Video, Chat,


Conference as means of
communication
Supports multiple language

Complying

Minimum of 1Year Technical


Support from Vendor

Complying

Complying

Not specifically
stated in the technical
proposal of the
winning bidder.
-do-do-do-do-do-do-do-

Training must be conducted by


Professional Trainers.
Professional Trainers must have
Level 1 and Level 2

Comply. Strategic
Planning for Business
Intelligence Workshop
will be conducted.
Comply. Strategic
Planning for Business

Training must be conducted by


Professional Trainers.

Complying

Professional Trainers must have


Level 1 and Level 2

Complying
39

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Certification or any equivalent


Business Intelligence
Certification
Training must be conducted in a
workshop environment
Workshop manuals must be
provided for all training course
Ratio of Workshop Manuals
must be 1:1
Meals should be included on
the Workshop
Transportation and incidental
expenses must shouldered by
the system integrator
An Examination must be
provided at the end of the
workshop
4.2

Winning Bidders
Specifications

Intelligence Workshop
will be conducted.
Comply. Strategic
Planning for Business
Intelligence Workshop
will be conducted.
Comply. Strategic
Planning for Business
Intelligence Workshop
will be conducted.
Comply. Strategic
Planning for Business
Intelligence Workshop
will be conducted.
Comply. Strategic
Planning for Business
Intelligence Workshop
will be conducted.
Comply. Strategic
Planning for Business
Intelligence Workshop
will be conducted.
Comply. Strategic
Planning for Business
Intelligence Workshop
will be conducted.

Contract

Certification or any equivalent


Business Intelligence
Certification
Training must be conducted in a
workshop environment

Information/ Data
Analysis

Complying

Workshop manuals must be


provided for all training course

Complying

Ratio of Workshop Manuals


must be 1:1

Complying

Meals should be included on


the Workshop

Complying

Transportation and incidental


expenses must shouldered by
the system integrator

Complying

An Examination must be
provided at the end of the
workshop

Complying

Training must be conducted by


Professional Trainers.

Complying

Professional Trainers must have


Level 1 and Level 2 Database
Certification or equivalent

Complying

Application Administration
Training
Application
Administration Training
-General Specifications
Training must be conducted by
Professional Trainers.
Professional Trainers must have
Level 1 and Level 2 Database
Certification or equivalent

Comply. Application
Administration General
Specifications will be
conducted.
Comply. Application
Administration General
Specifications will be

40

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Training must be conducted on


the Training Provider's own
Laboratory
Training manuals must be
provided for all training course
Ratio of Training Manuals must
be 1:1
Ratio of Workstation to be used
during the Training must be 1:1
Meals should be included on
the Training
A Certification Examination
must be provided after each
Training Course

Winning Bidders
Specifications

conducted.
Comply. Application
Administration General
Specifications will be
conducted.
Comply. Application
Administration General
Specifications will be
conducted.
Comply. Application
Administration General
Specifications will be
conducted.
Comply. Application
Administration General
Specifications will be
conducted.
Comply. Application
Administration General
Specifications will be
conducted.
Comply. Application
Administration General
Specifications will be
conducted.

Contract

Information/ Data
Analysis

Training must be conducted on


the Training Provider's own
Laboratory

Complying

Training manuals must be


provided for all training course

Complying

Ratio of Training Manuals must


be 1:1

Complying

Ratio of Workstation to be used


during the Training must be 1:1

Complying

Meals should be included on


the Training

Complying

A Certification Examination
must be provided after each
Training Course

Complying

Define the terminology and


explain the basic concepts of
data warehousing
Describe methods and tools for
extracting,
transforming, and loading data
Identify some of the tools for
accessing and analyzing
warehouse data
Identify the technology and

Complying

Six (6) Pax Application


Administration Training Data Warehouse
Fundamentals
Define the terminology and
explain the basic concepts of
data warehousing
Describe methods and tools for
extracting,
transforming, and loading data
Identify some of the tools for
accessing and analyzing
warehouse data
Identify the technology and

Comply. Datawarehouse
Fundamentals will be
conducted.
Comply. Datawarehouse
Fundamentals will be
conducted.
Comply. Datawarehouse
Fundamentals will be
conducted.
Comply. Datawarehouse

Complying
Complying
Complying
41

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

some of the tools from data


warehouse software to
implement a successful data
warehouse
Define the decision support
purpose and end
goal of a data warehouse
Describe the benefits of
partitioning, parallel operations,
views, and query rewrite in a
data warehouse
Explain the implementation and
organizational issues
surrounding a data warehouse
project
Use views and query rewrite to
improve the
data warehouse performance
Develop familiarity with some
of the technologies required to
implement a data warehouse

Fundamentals will be
conducted.

Review the basic data


warehousing concepts

Comply. Datawarehouse
Administration Training
will be conducted.
Comply. Datawarehouse
Administration Training
will be conducted.
Comply. Datawarehouse
Administration Training
will be conducted.
Comply. Datawarehouse
Administration Training
will be conducted.
Comply. Datawarehouse
Administration Training

Comply. Datawarehouse
Fundamentals will be
conducted.
Comply. Datawarehouse
Fundamentals will be
conducted.
Comply. Datawarehouse
Fundamentals will be
conducted.
Comply. Datawarehouse
Fundamentals will be
conducted.
Comply. Datawarehouse
Fundamentals will be
conducted.

Contract

some of the tools from data


warehouse software to
implement a successful data
warehouse
Define the decision support
purpose and end
goal of a data warehouse
Describe the benefits of
partitioning, parallel operations,
views, and query rewrite in a
data warehouse
Explain the implementation and
organizational issues
surrounding a data warehouse
project
Use views and query rewrite to
improve the
data warehouse performance
Develop familiarity with some
of the technologies required to
implement a data warehouse

Information/ Data
Analysis

Complying
Complying

Complying

Complying
Complying

Six (6) Pax Application


Administration Training
-Data Warehouse
Administration Training

Use parallel operations to


reduce response time for dataintensive operations
Extract, Transform, and Load
data in the data warehouse
Create, use, and refresh views
to improve the data warehouse
performance
Use Query rewrite to quickly
answer business queries using

Review the basic data


warehousing concepts

Complying

Use parallel operations to


reduce response time for dataintensive operations
Extract, Transform, and Load
data in the data warehouse

Complying

Create, use, and refresh views


to improve the data warehouse
performance
Use Query rewrite to quickly
answer business queries using

Complying

Complying

Complying
42

Item
No.

4.3

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

views
Use SQL Access Advisor and
PL/SQL
procedures to tune views for
fast refresh and query rewrite
Use the features of compression
and resumable sessions

will be conducted.
Comply. Datawarehouse
Administration Training
will be conducted.

Training must be conducted by


Professional Trainers.

Comply. Database
Administration Training
General Specifications
will be conducted.
Comply. Database
Administration Training
General Specifications
will be conducted.
Comply. Database
Administration Training
General Specifications
will be conducted.
Comply. Database
Administration Training
General Specifications
will be conducted.
Comply. Database
Administration Training
General Specifications
will be conducted.
Comply. Database
Administration Training
General Specifications
will be conducted.
Comply. Database
Administration Training

Comply. Datawarehouse
Administration Training
will be conducted.

Contract

views
Use SQL Access Advisor and
PL/SQL
procedures to tune views for
fast refresh and query rewrite
Use the features of compression
and resumable sessions

Information/ Data
Analysis

Complying

Complying

Database Administration
Training
Database Administration
Training - General
Specifications

Professional Trainers must have


Level 1 and Level 2 Database
Certification
Training must be conducted on
the Training Provider's own
Laboratory
Training manuals must be
provided for all training course
Ratio of Training Manuals must
be 1:1
Ratio of Workstation to be used
during the Training must be 1:1
Meals should be included on
the Training

Training must be conducted by


Professional Trainers.

Complying

Professional Trainers must have


Level 1 and Level 2 Database
Certification

Complying

Training must be conducted on


the Training Provider's own
Laboratory

Complying

Training manuals must be


provided for all training course

Complying

Ratio of Training Manuals must


be 1:1

Complying

Ratio of Workstation to be used


during the Training must be 1:1

Complying

Meals should be included on


the Training

Complying
43

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

A Certification Examination
must be provided after each
Training Course

Winning Bidders
Specifications

General Specifications
will be conducted.
Comply. Database
Administration Training
General Specifications
will be conducted.

Contract

Information/ Data
Analysis

A Certification Examination
must be provided after each
Training Course

Complying

Comply. Database
Administration Training
Comply. Database
Administration Training
Comply. Database
Administration Training
Comply. Database
Administration Training
Comply. Database
Administration Training
Comply. Database
Administration Training
Comply. Database
Administration Training
Comply. Database
Administration Training
Comply. Database
Administration Training

Monitor performance

Complying

Describe Database Architecture

Complying

Install Database Grid


Infrastructure
Install and configure Database

Complying

Monitor and administer undo


data
Manage the database storage
structures
Create and administer user
accounts
Perform basic backup and
recovery of a database
Manage data concurrency

Complying

Comply. Database
Administration Training
Comply. Database
Administration Training

Back and recover a database

Complying

Use an appropriate and flexible


memory configuration for your
database
Identify burdensome database
sessions and poorly performing

Complying

Six (6) Pax Database


Administration TrainingDatabase Administration
Trainer I

Monitor performance
Describe Database Architecture
Install Database Grid
Infrastructure
Install and configure Database
Monitor and administer undo
data
Manage the database storage
structures
Create and administer user
accounts
Perform basic backup and
recovery of a database
Manage data concurrency

Complying

Complying
Complying
Complying
Complying

Six (6) Pax Database


Administration Training
Database
Administration Training
II
Back and recover a database
Use an appropriate and flexible
memory configuration for your
database
Identify burdensome database
sessions and poorly performing

Comply. Database
Administration Training

Complying
44

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

SQL
Configure the Database for
optimal recovery
Configure the database instance
such that resources are
appropriately allocated among
sessions and tasks
Schedule jobs to run inside or
outside of the database
Use compression to optimize
database storage and duplicate a
database

Winning Bidders
Specifications

Comply. Database
Administration Training
Comply. Database
Administration Training
Comply. Database
Administration Training
Comply. Database
Administration Training

Contract

SQL
Configure the Database for
optimal recovery
Configure the database instance
such that resources are
appropriately allocated among
sessions and tasks
Schedule jobs to run inside or
outside of the database
Use compression to optimize
database storage and duplicate a
database

Information/ Data
Analysis

Complying
Complying

Complying
Complying

Six (6) Pax Database


Administration Training
SQL and PL/SQL
Fundamentals
Use PL/SQL programming
constructs and conditionally
control code flow (loops,
control structures, and explicit
cursors)
Use cursors to process rows
Identify the major structural
components of the Database
Retrieve row and column data
from tables with the SELECT
statement.
Create reports of sorted and
restricted data.
Employ SQL functions to
generate and retrieve
customized data.
Display data from multiple
tables using the ANSI SQL 99
JOIN syntax.
Create reports of aggregated
data.
Run data definition language

Comply. SQL and


PL/SQL Fundamentals

Comply. SQL and


PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and

Use PL/SQL programming


constructs and conditionally
control code flow (loops,
control structures, and explicit
cursors)
Use cursors to process rows

Complying

Identify the major structural


components of the Database
Retrieve row and column data
from tables with the SELECT
statement.
Create reports of sorted and
restricted data.
Employ SQL functions to
generate and retrieve
customized data.
Display data from multiple
tables using the ANSI SQL 99
JOIN syntax.
Create reports of aggregated
data.
Run data definition language

Complying

Complying

Complying
Complying
Complying
Complying
Complying
Complying
45

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

(DDL) statements to create and


manage schema objects
Run data manipulation
statements (DML) to update
data in the Database.
Design PL/SQL anonymous
block that execute efficiently.
Describe the features and
syntax of PL/SQL.
Handle runtime errors
Describe stored procedures and
function

Winning Bidders
Specifications

PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals
Comply. SQL and
PL/SQL Fundamentals

Contract

(DDL) statements to create and


manage schema objects
Run data manipulation
statements (DML) to update
data in the Database.
Design PL/SQL anonymous
block that execute efficiently.
Describe the features and
syntax of PL/SQL.
Handle runtime errors

Information/ Data
Analysis

Complying
Complying
Complying
Complying

Describe stored procedures and


function

Complying

Create and debug stored


procedures and functions
Use conditional compilation to
customize the functionality in a
Pt SQL application without
removing any source code
Design PL/SQL packages to
group related constructs
Create overloaded. package
subprograms for more
flexibility
Design PLSQL anonymous
blocks that execute efficiently
Use the supplied PL/SQL
packages to generate screen
output, file output and mail
output
Write dynamic SQL for more
coding flexibility
Describe the features and
syntax of PL/SQL
Use PL/SQL programming
constructs and conditionally

Complying

Six (6) Pax Database


Administration Training Program with PL/SQL
Create and debug stored
procedures and functions
Use conditional compilation to
customize the functionality in a
Pt SQL application without
removing any source code
Design PL/SQL packages to
group related constructs
Create overloaded. package
subprograms for more
flexibility
Design PLSQL anonymous
blocks that execute efficiently
Use the supplied PL/SQL
packages to generate screen
output, file output and mail
output
Write dynamic SQL for more
coding flexibility
Describe the features and
syntax of PL/SQL
Use PL/SQL programming
constructs and conditionally

Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL

Complying

Complying
Complying
Complying
Complying

Complying
Complying
Complying
46

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

control code flow (loops,


control structures, and explicit
cursors)
Manage dependencies between
PL/SQL subprograms
Handle runtime errors

Six (6) Pax Database


Administration Training
-Advanced PL/SQL

Create triggers to solve


business challenges
Design PL/SQL code for
predefined data types, local
subprograms, additional
pragmas, standardized constants
and exceptions

Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL
Comply. Programming
with PL/SQL

Contract

control code flow (loops,


control structures, and explicit
cursors)
Manage dependencies between
PL/SQL subprograms
Handle runtime errors

Information/ Data
Analysis

Complying
Complying

Create triggers to solve


business challenges
Design PL/SQL code for
predefined data types, local
subprograms, additional
pragmas, standardized constants
and exceptions

Complying

Design PL/SQL packages and


program units that execute
efficiently
Write code to interface with
external applications and the
operating system
Create PL/SQL applications
that use collections

Complying

Write and tune PL/SQL code


effectively to maximize
performance
Implement a virtual private
database with fine-grained
access control
Write code to interlace with
large objects and use SecureFile
LOB

Comply. Advanced
PL/SQL will be
conducted
Comply. Advanced
PL/SQL will be
conducted
Comply. Advanced
PL/SQL will be
conducted
Comply. Advanced
PL/SQL will be
conducted
Comply. Advanced
PL/SQL will be
conducted
Comply. Advanced
PL/SQL will be
conducted

Write and tune PL/SQL code


effectively to maximize
performance
Implement a virtual private
database with fine-grained
access control
Write code to interlace with
large objects and use SecureFile
LOB

Complying

Training must be provided by a


Partner of the Business

Comply. General
Specifications will be

Training must be provided by a


Partner of the Business

Complying

Design PL/SQL packages and


program units that execute
efficiently
Write code to interface with
external applications and the
operating system
Create PL/SQL applications
that use collections

4.4

Winning Bidders
Specifications

Complying

Complying
Complying

Complying
Complying

Reports Writing Training


Reports Writing Training
General Specifications

47

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Intelligence to be used for the


Blade Servers
Training must be conducted by
Professional Trainers
Professional Trainers must have
Level 1 and Level 2
Certification or any equivalent
Business Intelligence
Certification
Training must he conducted on
the Training Provider's own
Laboratory
Training manuals must be
provided for all training course
Ratio of Training Manuals must
be 1:1
Ratio of Workstation to be used
during the Training must be 1:1
Meals should be included on
the Training
A Certification Examination
must be provided after each
Training Course

Winning Bidders
Specifications

conducted
Comply. General
Specifications will be
conducted
Comply. General
Specifications will be
conducted
Comply. General
Specifications will be
conducted
Comply. General
Specifications will be
conducted
Comply. General
Specifications will be
conducted
Comply. General
Specifications will be
conducted
Comply. General
Specifications will be
conducted
Comply. General
Specifications will be
conducted

Contract

Intelligence to be used for the


Blade Servers
Training must be conducted by
Professional Trainers

Information/ Data
Analysis

Complying

Professional Trainers must have


Level 1 and Level 2
Certification or any equivalent
Business Intelligence
Certification
Training must he conducted on
the Training Provider's own
Laboratory
Training manuals must be
provided for all training course

Complying

Ratio of Training Manuals must


be 1:1

Complying

Ratio of Workstation to be used


during the Training must be 1:1

Complying

Meals should be included on


the Training

Complying

A Certification Examination
must be provided after each
Training Course

Complying

Build the Physical, Business


Model and Mapping, and
Presentation layers of a
Repository
Build and run analyses to test
and Validate a repository

Complying

Build simple and calculated

Complying

Complying
Complying

Sixteen (16) Pax Reports


Writing Training-Build
Repository Training
Build the Physical, Business
Model and Mapping, and
Presentation layers of a
Repository
Build and run analyses to test
and Validate a repository
Build simple and calculated

Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build

Complying

48

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

measures for a fact table


Create logical dimension
hierarchies and level-based
measures
Model aggregate tables to speed
query processing
Model partitions and fragments
to improve application
performance and usability
Use variables to streamline
administrative tasks and modify
metadata content dynamically
Use time series functions to
support historical time
comparison analyses
Set up security to authenticate
users and assign appropriate
permissions and privileges
Apply cache management
techniques to maintain and
enhance query performance
Set up query logging for testing
and debugging
Set upa multiuser development
environment
Use Administration Tool
wizards and utilities to manage,
maintain, and enhance
repositories
Enable usage tracking to track
queries and database usage, and
improve query performance
Perform a patch merge in a
development-to-production
scenario

Winning Bidders
Specifications

Repository Training will


be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted
Comply. Build
Repository Training will
be conducted

Contract

Information/ Data
Analysis

measures for a fact table


Create logical dimension
hierarchies and level-based
measures
Model aggregate tables to speed
query processing

Complying

Model partitions and fragments


to improve application
performance and usability
Use variables to streamline
administrative tasks and modify
metadata content dynamically
Use time series functions to
support historical time
comparison analyses
Set up security to authenticate
users and assign appropriate
permissions and privileges
Apply cache management
techniques to maintain and
enhance query performance
Set up query logging for testing
and debugging

Complying

Set upa multiuser development


environment

Complying

Use Administration Tool


wizards and utilities to manage,
maintain, and enhance
repositories
Enable usage tracking to track
queries and database usage, and
improve query performance
Perform a patch merge in a
development-to-production
scenario

Complying

Complying

Complying
Complying
Complying
Complying
Complying

Complying
Complying

49

Item
No.

4.5

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Training must be provided by a


Partner of the Linux Operating
System to be used for the Blade
Servers

Comply. Enterprise Linux


Professional Systems and
Network Admin Training
- General Specifications
will be conducted
Comply. Enterprise Linux
Professional Systems and
Network Admin Training
- General Specifications
will be conducted
Comply. Enterprise Linux
Professional Systems and
Network Admin Training
- General Specifications
will be conducted
Comply. Enterprise Linux
Professional Systems and
Network Admin Training
- General Specifications
will be conducted
Comply. Enterprise Linux
Professional Systems and
Network Admin Training
- General Specifications
will be conducted
Comply. Enterprise Linux
Professional Systems and
Network Admin Training
- General Specifications
will be conducted
Comply. Enterprise Linux
Professional Systems and

Contract

Information/ Data
Analysis

Enterprise Linux
Professional Systems and
Network Admin Training
Enterprise Linux
Professional Systems
and Network Admin
Training - General
Specifications

Training must be conducted by


Professional Trainers

Professional Trainers must have


Level 1 and Level 2 Linux
Certification
Training must be conducted on
the Training Provider's own
Laboratory
Training manuals must be
provided for all. training
course

Ratio of Training Manuals must


be 1:1
Ratio of Workstation to be
used during the Training must

Training must be provided by a


Partner of the Linux Operating
System to be used for the Blade
Servers

Complying

Training must be conducted by


Professional Trainers

Complying

Professional Trainers must have


Level 1 and Level 2 Linux
Certification

Complying

Training must be conducted on


the Training Provider's own
Laboratory

Complying

Training manuals must be


provided for all. training
course

Complying

Complying
Ratio of Training Manuals must
be 1:1
Ratio of Workstation to be
used during the Training must

Complying
50

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

be 1:1

Meals should be included on


the Training
A Certification Examination
must be provided after each
Training Course

Winning Bidders
Specifications

Network Admin Training


- General Specifications
will be conducted
Comply. Enterprise Linux
Professional Systems and
Network Admin Training
- General Specifications
will be conducted
Comply. Enterprise Linux
Professional Systems and
Network Admin Training
- General Specifications
will be conducted

Contract

Information/ Data
Analysis

be 1:1
Complying
Meals should be included on
the Training
A Certification Examination
must be provided after each
Training Course

Complying

Six (6) Pax Enterprise


Linux Professional
Systems and Network
Admin Training Linux
Systems
Administration Training
File Permission and Ownership
Management
Creation, Deletion, Searching
and Displaying of Files
Archiving and Compression of
Directories
Introduction to Process Text
Streams and usage of Filters
Introduction to the Command
Line
Usage of Streams, Pipes and
Redirections
Searching of Tech Files using
Regular Expressions

Comply. Linux Systems


Administration Training
will be conducted
Comply. Linux Systems
Administration Training
will be conducted
Comply. Linux Systems
Administration Training
will be conducted
Comply. Linux Systems
Administration Training
will be conducted
Comply. Linux Systems
Administration Training
will be conducted
Comply. Linux Systems
Administration Training
will be conducted
Comply. Linux Systems
Administration Training

File Permission and Ownership


Management
Creation, Deletion, Searching
and Displaying of Files
Archiving and Compression of
Directories
Introduction to Process Text
Streams and usage of Filters
Introduction to the Command
Line
Usage of Streams, Pipes and
Redirections
Searching of Tech Files using
Regular Expressions

Complying
Complying
Complying
Complying
Complying
Complying
Complying
51

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

will be conducted
Comply. Linux Systems
Performing Basic File Edition
Administration Training
using vi tool
will be conducted
Creation, Monitoring and
Comply. Linux Systems
stopping of processes
Administration Training
will be conducted
Introduction to RPM, Yum and Comply. Linux Systems
the Debian Package Management Administration Training
will be conducted
Comply. Linux Systems
Filesystems Management
Administration Training
will be conducted
Comply. Linux Systems
Introduction to the Linux Boot
Administration Training
Process
will be conducted
Comply. Linux Systems
Configuration of Hardware
Administration Training
Settings on Linux
will be conducted

Contract

Performing Basic File Edition


using vi tool

Information/ Data
Analysis

Complying

Creation, Monitoring and


stopping of processes

Complying

Introduction to RPM, Yum and


the Debian Package Management

Complying
Complying

Filesystems Management
Introduction to the Linux Boot
Process
Configuration of Hardware
Settings on Linux

Complying
Complying

Six (6) Pax Enterprise


Linux Professional
Systems and Network
Admin Training
Advanced Linux System
Administration Training
User Account and Security
Administration
Customization of Linux Shell
and Creating Simple Shell
Scripts
Automation and Scheduling of
Tasks
Linux Networking

Comply. Advanced Linux


System Administration
Training will be
conducted
Comply. Advanced Linux
System Administration
Training will be
conducted
Comply. Advanced Linux
System Administration
Training will be
conducted
Comply. Advanced Linux
System Administration

User Account and Security


Administration

Complying

Customization of Linux Shell


and Creating Simple Shell
Scripts

Complying

Automation and Scheduling of


Tasks

Complying

Linux Networking

Complying
52

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Understanding the X Windows


System
Displaying of Time, Logs and
Print Cue
Mail Transfer Agent and SQL
Fundamentals
Securing server and applying
encryption
Six (6) Pax Enterprise
Linux Professional
Systems and Network
Admin Training - Linux
Network Services and
Security Administration
Training
Understanding Linux Boot
Process
Introduction to the Linux
Rescue Environment
Components and Compiling of
the Linux Kernel
Linux Filesystem Management

Winning Bidders
Specifications

Training will be
conducted
Comply. Advanced Linux
System Administration
Training will be
conducted
Comply. Advanced Linux
System Administration
Training will be
conducted
Comply. Advanced Linux
System Administration
Training will be
conducted
Comply. Advanced Linux
System Administration
Training will be
conducted

Comply. Linux Network


Services and Security
Administration Training
will be conducted
Comply. Linux Network
Services and Security
Administration Training
will be conducted
Comply. Linux Network
Services and Security
Administration Training
will be conducted
Comply. Linux Network
Services and Security
Administration Training

Contract

Information/ Data
Analysis

Understanding the X Windows


System

Complying

Displaying of Time, Logs and


Print Cue

Complying

Mail Transfer Agent and SQL


Fundamentals

Complying

Securing server and applying


encryption

Complying

Understanding Linux Boot


Process

Complying

Introduction to the Linux


Rescue Environment

Complying

Components and Compiling of


the Linux Kernel

Complying

Linux Filesystem Management

Complying

53

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Understanding Logical Volume


Manager and Linux Software
RAID
Client-Server Networking

System Maintenance

Introduction to Linux Domain


Name Server
Configuring and Securing a
Linux Domain Name Server
Six (6) Pax Enterprise
Linux Profestional
Systems and Network
Admin Training
Advanced Linux
Network Services and
Security Administration
Training

Installation and Configuration


of a Linux Web Server

Administering a Linux Web


Server
Installation and Configuration

Winning Bidders
Specifications

will be conducted
Comply. Linux Network
Services and Security
Administration Training
will be conducted
Comply. Linux Network
Services and Security
Administration Training
will be conducted
Comply. Linux Network
Services and Security
Administration Training
will be conducted
Comply. Linux Network
Services and Security
Administration Training
will be conducted
Comply. Linux Network
Services and Security
Administration Training
will be conducted

Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced

Contract

Information/ Data
Analysis

Understanding Logical Volume


Manager and Linux Software
RAID

Complying

Client-Server Networking

Complying

System Maintenance

Complying

Introduction to Linux Domain


Name Server

Complying

Configuring and Securing a


Linux Domain Name Server

Complying

Installation and Configuration


of a Linux Web Server

Complying

Complying
Administering a Linux Web
Server
Installation and Configuration

Complying
54

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

of Linux Proxy and DHCP


Server

Installation and Configuration


of Linux Samba Server

Installation and Configuration


of
Linux
Network File Server and File
Transfer Protocol Server

Securing FTP Server


Authenticating using PAM and
LDAP Client Administration

Introduction to Linux Mail


Servers
Installation, Configuration and
Management of Local and
Remote Linux Mail Server

Configuring a Linux Server as


Router and Securing Linux
Shell

Linux Services using TCP

Winning Bidders
Specifications

Linux Network Services


and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced

Contract

of Linux Proxy and DHCP


Server

Information/ Data
Analysis

Installation and Configuration


of Linux Samba Server

Complying

Installation and Configuration


of
Linux
Network File Server and File
Transfer Protocol Server

Complying

Complying
Securing FTP Server
Authenticating using PAM and
LDAP Client Administration

Complying

Complying
Introduction to Linux Mail
Servers
Installation, Configuration and
Management of Local and
Remote Linux Mail Server

Complying

Configuring a Linux Server as


Router and Securing Linux
Shell

Complying

Linux Services using TCP

Complying
55

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Wrappers
Identifying and
Troubleshooting of Linux Boot
Loaders

General Linux Troubleshooting

Troubleshooting of Linux
System Resources

Troubleshooting of Linux
Environment Setting
4.6

Winning Bidders
Specifications

Linux Network Services


and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted
Comply. Advanced
Linux Network Services
and Security
Administration Training
will be conducted

Contract

Information/ Data
Analysis

Wrappers
Identifying and
Troubleshooting of Linux Boot
Loaders

Complying

Complying
General Linux Troubleshooting
Complying
Troubleshooting of Linux
System Resources
Complying
Troubleshooting of Linux
Environment Setting

Security Information and


Events Management
Training
Six (6) Pax Security
Information and Events
Management Training
Training must be conducted by
Professional Trainers
Professional Trainers must have
Level I and Level 2 Security
Certification or
any
equivalent Certification
Training must be conducted on,
the Training Provider's own

Comply. Security
Information and Events
Management Training
will be conducted
Comply. Security
Information and Events
Management Training
will be conducted
Comply. Security
Information and Events

Training must be conducted by


Professional Trainers

Complying

Professional Trainers must have


Level I and Level 2 Security
Certification or
any
equivalent Certification

Complying

Training must be conducted on,


the Training Provider's own

Complying
56

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Laboratory
Training manuals must be
provided for all training course

Ratio of Training Manuals must


be 1:1
Ratio of Workstation to be used
during the Training must be 1:1

Meals should be included on


the Training
An Examination must be
provided after each Training
Course
In depth training on the
implementation and
management of the SIEM
Server
Introduction to security threat

Monitoring of systems

4.7

Winning Bidders
Specifications

Contract

Management Training
will be conducted
Comply. Security
Information and Events
Management Training
will be conducted
Comply. Security
Information and Events
Management Training
will be conducted
Comply. Security
Information and Events
Management Training
will be conducted
Comply. Security
Information and Events
Management Training
will be conducted
Comply. Security
Information and Events
Management Training
will be conducted
Comply. Security
Information and Events
Management Training
will be conducted
Comply. Security
Information and Events
Management Training
will be conducted
Comply. Security
Information and Events
Management Training
will be conducted

Laboratory

Comply. Walk-through
and Technology Transfer
will be conducted

Training manuals must be


provided for all training course

Information/ Data
Analysis

Complying

Complying
Ratio of Training Manuals must
be 1:1
Ratio of Workstation to be used
during the Training must be 1:1

Meals should be included on


the Training

Complying

Complying

An Examination must be
provided after each Training
Course

Complying

In depth training on the


implementation and
management of the SIEM
Server
Introduction to security threat

Complying

Monitoring of systems

Complying

1 Day Walkthrough on the


Implemented Systems

Complying

Complying

Walk-through and
Technology Transfer
1 Day Walkthrough on the
Implemented Systems

57

Item
No.

4.8

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Contract

Information/ Data
Analysis

Technical Systems Training


Four (4) Pax Technical
Systems Training
Site inspection from the system
integrator of a similar setup
Setup must be similar to the
systems implemented at DOF
Training must be done on the
Systems Integrator's facility
Transportation and incidental
expense must be shouldered by
the systems integrator

4.9

Winning Bidders
Specifications

Comply. Technical
Systems Training will
be conducted
Comply. Technical
Systems Training will
be conducted
Comply. Technical
Systems Training will
be conducted
Comply. Technical
Systems Training will
be conducted

Site inspection from the system


integrator of a similar setup

Complying

Setup must be similar to the


systems implemented at DOF

Complying

Training must be done on the


Systems Integrator's facility

Complying

Transportation and incidental


expense must be shouldered by
the systems integrator

Complying

Comply. Executive
Briefing and Technical
Sessions will be
conducted locally

Vendor Technical Product


Update focused on latest trendson Hardware Infrastructure,
Software Solutions and
Database Management
Observatory meeting must
include business strategic
management innovations and
best practices on integrated
systems, business applications
and software engineering
Must attend a technical session
from a highly anticipated
corporate IT event

Complying

Must include convention fees,


accommodation, transportation
and other incidental expense

Complying

Executive Briefing and


Technical Sessions
Four (4) Pax Executive
Briefing and Technical
Sessions
Vendor Technical Product
Update focused on latest trendson Hardware Infrastructure,
Software Solutions and
Database Management
Observatory meeting must
include business strategic
management innovations and
best practices on integrated
systems, business applications
and software engineering
Must attend a technical session
from a highly anticipated
corporate IT event
Must include convention fees,
accommodation, transportation
and other incidental expense

Comply. Executive
Briefing and Technical
Sessions will be
conducted locally
Comply. Executive
Briefing and Technical
Sessions will be
conducted locally
Comply. Executive
Briefing and Technical
Sessions will be
conducted locally

Complying

Complying

58

Item
No.

4.10

Description

Information Technology
Infrastructure Library V3
Training with Certification
Four (4) Pax Information
Technology Infrastructure
Library V3 Training with
Certification

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Winning Bidders
Specifications

Training must he conducted by Comply. Information


Professional Trainers.
Technology Infrastructure
Library V3 Training with
Certification will be
conducted
Professional Trainers must be
Comply. Information
ITIL Certified or any equivalent Technology Infrastructure
Certifications
Library V3 Training with
Certification will be
conducted
Training must be conducted on
Comply. Information
the Training Provider's own
Technology Infrastructure
Laboratory
Library V3 Training with
Certification will be
conducted
Training manuals must be
Comply. Information
provided for all training course Technology Infrastructure
Library V3 Training with
Certification will be
conducted
Comply. Information
Technology Infrastructure
Ratio of Training Manuals must
Library V3 Training with
be 1:1
Certification will be
conducted
Comply. Information
Technology Infrastructure
Meals should be included on
Library V3 Training with
the Training
Certification will be
conducted
A Certification Examination
Comply. Information
must be provided after each
Technology Infrastructure
Training Course
Library V3 Training with

Contract

Information/ Data
Analysis

Training must he conducted by Complying


Professional Trainers.

Professional Trainers must be


ITIL Certified or any equivalent
Certifications

Complying

Training must be conducted on


the Training Provider's own
Laboratory

Complying

Training manuals must be


provided for all training course

Complying

Complying
Ratio of Training Manuals must
be 1:1
Complying
Meals should be included on
the Training
A Certification Examination
must be provided after each
Training Course

Complying
59

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Information Technology
Infrastructure Library V3
Foundation

Introduction to Information
Technology Infrastructure
Library

Information Technology
Infrastructure Library Concepts

Continuous Service
Improvement

Service Operation

Service Transition

Service Design
Service Strategy

Winning Bidders
Specifications

Certification will be
conducted
Comply. Information
Technology Infrastructure
Library V3 Training with
Certification will be
conducted
Comply. Information
Technology Infrastructure
Library V3 Training with
Certification will be
conducted
Comply. Information
Technology Infrastructure
Library V3 Training with
Certification will be
conducted
Comply. Information
Technology Infrastructure
Library V3 Training with
Certification will be
conducted
Comply. Information
Technology Infrastructure
Library V3 Training with
Certification will be
conducted
Comply. Information
Technology Infrastructure
Library V3 Training with
Certification will be
conducted
Comply. Information
Technology Infrastructure
Library V3 Training with
Certification will be
conducted
Comply. Information
Technology Infrastructure
Library V3 Training with

Contract

Information/ Data
Analysis

Information Technology
Infrastructure Library V3
Foundation

Complying

Introduction to Information
Technology Infrastructure
Library

Complying

Information Technology
Infrastructure Library Concepts

Complying

Complying
Continuous Service
Improvement
Complying
Service Operation
Complying
Service Transition
Complying
Service Design
Service Strategy

Complying
60

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Review Program
4.11

Winning Bidders
Specifications

Certification will be
conducted
Comply. Information
Technology Infrastructure
Library V3 Training with
Certification will be
conducted

Contract

Information/ Data
Analysis

Complying
Review Program

Project Management
Training and Certification
Four (4) Pax Project
Management Training
with Certification
Training must be conducted by
Professional Trainers.
Professional Trainers must be
Certified on Project
Management or any equivalent
certifications
Training must be conducted on
the Training Provider's own
Laboratory
Training manuals must be
provided for all training course

Ratio of Training Manuals


must be 1:1
Meals should be included on
the Training
A Certification Examination
must he provided after each
Training Course

Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted

Training must be conducted by


Professional Trainers.

Complying

Professional Trainers must be


Certified on Project
Management or any equivalent
certifications
Training must be conducted on
the Training Provider's own
Laboratory

Complying

Training manuals must be


provided for all training course

Complying

Complying

Complying
Ratio of Training Manuals
must be 1:1
Complying
Meals should be included on
the Training
A Certification Examination
must he provided after each
Training Course

Complying

61

Item
No.

Description

Source Documents

Submitted
Yes
No

Agency Requirements/
Specifications

Understanding the Process of


Managing Projects
Building Projects from a Clear
Need
Documenting Requirements:
Building the Project Plan
Project Selection: Keys to
Success
How Realities of
Organizational Life Affect
Projects
Capable People: The Heart of
Every Project
Setting the Project Course:
Tools and Techniques for
Planning
Managing Change: Keeping the
Project on Course
Closing Out the Project With
Positive Results

Winning Bidders
Specifications

Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted
Comply. Project
Management Training
with Certification will be
conducted

Contract

Information/ Data
Analysis

Understanding the Process of


Managing Projects

Complying

Building Projects from a Clear


Need

Complying

Documenting Requirements:
Building the Project Plan

Complying

Project Selection: Keys to


Success

Complying

How Realities of
Organizational Life Affect
Projects

Complying

Capable People: The Heart of


Every Project

Complying

Setting the Project Course:


Tools and Techniques for
Planning

Complying

Managing Change: Keeping the


Project on Course

Complying

Closing Out the Project With


Positive Results

Complying

62

Prepared by:

Reviewed by:
NANNETTE JUNE V. ACUA
Technical Audit Specialist II

BENILDA E. MENDOZA
State Auditor V
Technical Service Chief

MA. FILOMENA B. LIM


Information Technology Officer I

63

Вам также может понравиться