Вы находитесь на странице: 1из 23

BUILDING CONTRACTOR/HOME OWNER

TO REVIEW AND VERIFY ALL DIMENSIONS,


SPECS, AND CONNECTIONS BEFORE
CONSTRUCTION BEGINS.
ELECTRICAL SYSTEM CODE: SEC.2701
MECHANICAL SYSTEM CODE: SEC.2801
PLUMBING SYSTEM CODE: SEC.2901

Page 1 Cover Page


Page 2 Main Floor Plan
Page 3 Basement Plan
Page 4 Elevation Plan
Page 5 Typical Section Details
Page 6 Floor and Roof Framing Plan
Page 7 Whole House Section
Page 8 Cabinet & Stair Detailsl
Page 9 Main Electrical
Page 10 Basement Electrical
Page 11 Misc Details
Page 12 Plot Plan

To the best of my knowledge these plans are


drawn to comply with owner's and/ or builder's
specifications and any changes made on them
after prints are made will be done at the owner's
and / or builder's expence and responsibility. The
contractor shall verify all dimensions and enclosed
drawing. SDSCAD is not liable for errors once
construction has begun. While every affort has
been made in the preparation of this plan to avoid
mistakes, the maker can not guarantee against
human error. The contractor of the job must check
all dimensions and other details prior to
construction and be solely responsible thereafter.
All calculations and member sizing should be
verified for your building by a certified building
official.

CLIENT
DATE

07/18/2004

DRWN BY

John Davidson

CHK'D BY
DATE

REVISIONS

JOB NO.

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

Residential Design

SDS-CAD
Specialized Design Systems

Custom Home Design


By SDS-CAD Specialized Design Systems
Plan 63

1
OF

11

Residential Design

DN

27'-7"
4'-0"

6'-0"

3'-8"

12'-5"

3'-4"

6'-0"

3'-4"

3460

1'-3"

2'-1"

3'-0"

3460

10'-0"

2'-9"

3'-0"

3050

3050

41078

4" Concrete with


WWM over
compacted gravel fill
sloped to door
1" slope per 10' to
garage door

3'-5"

6'-10"

GARAGE
30'-6" x 23'-6"

DATE

2- 1 3/4" x 11 7/8" LVL Header

2- 1 3/4" x 14" LVL Header

9070

16'-0"
20'-0"

07/18/2004

DRWN BY

John Davidson

CHK'D BY
DATE

REVISIONS

16080

2'-0"

2'-0"

1'-0"

9'-0"

1'-6"

11'-6"

50'-0"
JOB NO.

MAIN FLOOR PLAN


SCALE 1/8"=1'

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

SDS-CAD
Specialized Design Systems
CLIENT

2'-0"

4030

Garage Door Wall Single


Sheet Both sides of wall
w/ 7/16" D.S.B. Nailed
8d@6"o.c. Edge and 12"
o.c. Field

5'-0"

4'-0"

18'-0"

Simpson HPAHD strap location marker

22'-4"

3'-5"

1264

17'-6"

2'-0"

5816
3068

1'-10"

Garage/House Wall
Single Sheet one side of
wall w/ 7/16" D.S.B.
Nailed 8d@6"o.c. Edge
and 12" o.c. Field

9'-0"

7'-4"

1264

5'-4"
3068

4'-10"

3068

3'-7"

BRACED WALLS AND ALT BRACED WALL OPTIONS


Brace all exterior walls and cross-stud partitions at each end of building and at
least every 25' of length by one of the following:
a. Simpson WB 126 wall bracing with 3-16d nails at each end and 1-8d nails at each stud.
b. Plywood sheathing of a minimum thickness of 3/8 inch.
c. Continuous bracing from floor to floor

9'-5"
5'-11"

CLOSET

6'-8"

12'-6"

4036

4'-0"

31068

4'-6"

3'-3"

5'-8"

BATH
4'-11" x 8'-0"

6'-3" x 8'-0"

8'-10"

LAUNDRY

8' Wall

54'-0"

CLOSET
1'-10" x 1'-11"

1'-10" x 4'-5"

11'-8"
ALTERNATE BRACE WALL PANELS
PROVIDE (2) STRAPS FOR B.W.P.

2'-11" 2'-0"

9'-11" x 12'-0"

2668

3'-0"

DN

4'-0"

1868

5'-2"
BEDROOM

2'-0"

2668

2668

7'-0"

4'-6"
1'-10"

3'-11"
x 1'-5"
4068

3'-9"

3'-9"

Kitchen to be
Designed by
Homeowner

DN

Simpson Strong-Tie
CS16

2026

2668
2668

CLOSET

11'-8"

Equal number of
specified nails in
each end

CLOSET

2668

2'-4"

Provide minimum 1"


end distance

3'-0"

9'-4" x 7'-4"

7478

END
LENGTH

9'-4" x 8'-9"

3'-8"

54'-0"
CLEAR
SPAN

4040

12'-0" x 16'-6"

2'-6"
BRACED WALL PANEL
4X8 SHT. ON FOUNDATION.
NAIL W/8d NAILS @6" O.C.
EDGES @12" O.C. IN FIELD.
NAIL BOTTOM TO SILL PLATE.

4'-10"

MASTER BDRM

Furnace Flue

CUT
LENGTH

4'-0"

MASTER BATH

NUMBER
W01
W02
W03
W04
W05
W06
W07
W08
W09
W10
W11
W12
W13
W14

END
LENGTH

1'-7"1'-2"

4'-6"

6068

3040

DESCRIPTION
LEFT SLIDING
FIXED GLASS
RIGHT SLIDING
FIXED GLASS
FIXED GLASS
RIGHT SLIDING
FIXED GLASS
AWNING
DOUBLE HUNG
DOUBLE HUNG
MULLED UNIT
DOUBLE HUNG
MULLED UNIT
24X24 OCTAGON

50'-0"

18'-5"

WINDOW SCHEDULE
SIZE
DIMENSIONS
4036
48"X42"
1264
14"X76"
4036
48"X42"
3460
40"X72"
4030
48"X36"
4040
48"X48"
5816
68"X18"
3040
36"X48"
3050
36"X60"
2026
24"X30"
41078
58"X92 1/4"
2030
24"X36"
7478
88"X92 1/4"
1818
20"X20"

DECK
12'-11" x 9'-7"

3'-0"

FLOOR
0
1
1
1
1
1
1
1
1
1
1
0
1
2

DOOR SCHEDULE
DIMENSIONS
DESCRIPTION
30X80X1 3/8"
3 PANEL DOOR - COLOR BRITE WHITE
192X96"
GARAGE 4-PANEL (LONG)
20X80X1 3/8"
3 PANEL DOOR - COLOR BRITE WHITE
30X80X1 3/8"
3 PANEL DOOR - COLOR BRITE WHITE
30X80X1 3/8"
POCKET
36X80X1 3/4"
EXT. 6-PANEL
46X80"
BIFOLD
24X80"
BIFOLD
36X80X1 3/4"
EXT. HINGED-GLASS
108X84"
GARAGE 2-PANEL
36X80X1 3/8"
3 PANEL DOOR - COLOR BRITE WHITE
72X80"
SLIDER
36X80X1 3/4"
EXT. HINGED-GLASS
30X80"
BIFOLD

/W

QTY
5
2
1
2
1
1
1
1
2
1
1
1
1
2

SIZE
2668
16080
1868
2668
2668
3068
31068
4068
6068
9070
3068
6068
3068
5068

NUMBER
W01
W02
W03
W04
W05
W06
W07
W08
W09
W10
W11
W12
W13
W14

FLOOR
0
1
1
1
1
1
1
1
1
1
1
0
0
0

2'-11"

QTY
8
1
1
5
1
2
1
1
1
1
1
2
1
2

24'-4"

NUMBER
D01
D02
D03
D04
D05
D06
D07
D08
D09
D10
D11
D12
D13
D14

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

2
OF

11

Residential Design

Concrete:
1. All slabs are to be 4" concrete over 4" gravel unless otherwise noted on the plans.
2. Concrete to be ACI 301-66, Type II cement, 2500 psi at 28 days, 5" maximum slump.
3. Reinforcing to be ASTM A615-Bars with Fy=60 ksi lamp 30 diameter minimum at splices or weld per ACI Std.
4. Concrete design based on Fc 2000 psf, Fc 2500 psi for quality only.
5. Anchor bolts shall be A-307 embedded 7" minimum into concrete or masonry grout.
50'-0"
25'-11"
6'-0"

6'-6"

4036

5'-5"

4'-0"

3068

1'-6"

4'-0"

5'-0"

4036

Bearing Wall
with footing

2'-9"

(2) 1 7/8" x 11 7/8" LVL Beam

(2) 1 7/8" x 11 7/8" LVL Beam

FOOTING SCHEDULE

5068

2668

HOUSE WALLS
DECKS & PORCHES
BEARING WALL
GARAGE WALL

2668

UP

2668

2030

2'-0"

6"

5068

6'-1 3/16"

5'-9 1/4"
Rough in for bath

4036

11'-8"

Block out for 3'


garage door

4" Concrete with


WWM over
compacted gravel fill
sloped to door
1" slope per 10' to
garage door

6'-9"

GARAGE

VENTING SCHEDULE
22'-4"

7'-6"

6'-7" x 8'-7"

11'-9"

Min 2 #4 Rebar Horizontal


on undisturbed or compacted soil

STORAGE

Range Hoods
All Bath Fans
Dryer Vent

Vent Through Roof


Vent to Exterior
Vent to Exterior

30'-2" x 23'-4"

CLIENT
DATE

Block out for 16' garage door

20'-0"
50'-0"

11'-6"

07/18/2004

DRWN BY

Block out for 9'


garage door

John Davidson

CHK'D BY
DATE

2'-0"

BEDROOM
10'-11" x 10'-11"

8' Foundation
Wall

8'-8"

Water
Softner

15'-1" x 11'-2"

20" x 10" Min


18" x 10" Min
20" x 10" Min
18" x 10" Min

18'-0"

54'-0"

2668

STORAGE

WH

11'-9"

68
26

4'-3"

UTILITY
8'-7" x

54'-0"

Provide Proper Fresh


Air Venting for # of
Gas Appliances
Floor Drain Required
Flue through Roof
Required if Direct
7'-5" Vent Appieces are
not installed

7'-6"

2'-8"

2668

6068

R-38 Min
R-19 Min
R-13 Min

2668

2'-10"

Bearing Wall
with footing

6068

10'-5" x 5'-4"

Ceilings
Wall above grade
Wall interior below grade

12'-0" x 14'-5"

25'-6" x 17'-2"

2668

4036

BEDROOM
FAMILY

2'-7"

4'-0"

10'-5" x 12'-3"

BATH

INSULATION SCHEDULE

Future Walls

BEDROOM

3'-2"

5'-8"

3'-10"

4036

Drop
Footing 30"
below walk
out door

2x12 joists 16" OC

13'-1"

12'-10"

3'-0"

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

4'-0"

SDS-CAD
Specialized Design Systems

2'-0"

15'-3"

11'-3"

REVISIONS

BASEMENT PLAN
SCALE 1/8"=1'
JOB NO.

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

3
OF

11

Residential Design

LEFT ELEVATION

SCALE 1/8"=1'

SCALE 1/8"=1'

REAR ELEVATION
SCALE 1/8"=1'

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

RIGHT ELEVATION

SDS-CAD
Specialized Design Systems

5/12
PITCH

ARCHITECTURAL
ASHPHALT
SHINGLES
6/12
PITCH
8/12
PITCH
Stucco

PERSPECTIVE VIEWS
CLIENT
DATE

07/18/2004

DRWN BY

John Davidson

CHK'D BY
DATE

REVISIONS

FRONT ELEVATION
SCALE 1/4"=1'

JOB NO.

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

4
OF

11

Residential Design

See
Elevations
for Pitch

VENT ATTIC PER CODE

12

VAULT AS DESIGNATED ON FLOOR PLAN

PREFABRICATED
TRUSSES @ 24" 0.C.
ASPHALT SHINGLES
OVER 30# FELT
ICE SHIELD 24" UP FROM WALL
AND ALL VALLEYS
5/8" PLY. SHEATHING

TRUSS CLIP
RAIN GUTTER
1/2" SHEETROCK

1 x 6 FASCIA
FINISH PER
ELEVATIONS

R-19 BATT INSULATION


2 x 6 STUD @ 16" O.C.

9'-0"

HOUSE WRAP OVER


7/16" PLY. SHEATHING

1/2" SHEETROCK

2 x 6 BOTTOM PLATE

2 x 11 7/8 TGI JOIST @ 16" O.C.


OR AS NOTED ON PLAN

3/4" PLYWOOD SUBFLOOR SCREW & GLUE

RIM JOIST
2 x 6 MUDSILL
1/2" x 10"
ANCHOR BOLT
EMBEDDED 7"
INTO CONC.

8"
MIN

7'-8"

1/2" REBAR
SPACED 24" HOR
& VERT 4" MIN
FROM TOP AND
BOTTOM

SEE NOTES FOR


HEADER SIZE

FIN. FLR. TO CLG.

2 x 6 DOUBLE TOP PLATE

BRICK OR ROCK WITH


1/2" AIRSPACE
BASEBOARD

BEARING WALL AS PER PLAN


2 x STUDS @ 16" O.C.
2x4 INSULATED WALL

2 - 1/2" REBAR
4" CONC. SLAB W/6 x 6 #10
WW MESH OR FIBER
4" GRAVEL & 6 MIL VAPOR SEAL

4" DRAIN TO DAYLIGHT IN


8" x 24" GRAVEL

ALUM. SOFFIT & FACIA

AS PER FLOOR PLAN

8' X 8"
FOUNDATION
WATERPROOF
TO GRADE

10" X 20" FOOTING


WITH 2 - 1/2" REBAR
CLIENT

10"

DATE

6"
6"

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

R-38 INSULATION

1'-6"

SDS-CAD
Specialized Design Systems

PREFABRICATED
TRUSSES @ 24" 0.C.

8"

07/18/2004

DRWN BY

John Davidson

CHK'D BY
DATE

20"

REVISIONS

TYPICAL HOUSE SECTION


SCALE NTS
JOB NO.

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

5
OF

11

5.
6.
7.
8.
9.

MAIN FLOOR FRAMING


SCALE 1/16"=1'

ROOF FRAMING
SCALE 1/16"=1'

4036

3068

4036

4036

2668

2668

2x12 joists 16" OC

4036

Bearing Wall

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

Fascia to be 2"x Douglas Fir.


For soffit size see details.
For spans and dimensions refer to floor plans.
Trusses are to be an approved truss design from the truss manufacture's engineer.
Install as per engineers specs
Use Simpson H-1 hurricane anchors at each truss or rafter to wall connection.
Solid blocking required between joists, rafters, and trusses over all bearing walls.
Such blocking shall be 1 " minimum thickness and full depth of joists, rafters, or trusses.
Minimum header sizes shall be according to the header size table unless otherwise noted.
Basis of design roof live/snow load of 37 psf, and roof dead load of 15 psf.
Plywood roof decking to be Min " thick, 24/0, CDX or 5/8 wafer.

SDS-CAD
Specialized Design Systems

1.
2.
3.
4.

Residential Design

Roof Framing:

6068

5/12 Pitch

2668

5/12 Pitch

SEE GENERAL SPECS AND


NOTES FOR FRAMING DETAILS

6/12 Pitch

4036

68
26

11 7/8"" I-Joists 16"


o.c Floor Joists.

5/12 Pitch
8/12 Pitch

2668

6068

8/12 Pitch

2668

2668

UP

6/12 Pitch

2030

5068

5068

2668

CLIENT
DATE

07/18/2004

DRWN BY

PRE-ENGINEERED ENERGY TRUSSES AS SUPPLIED BY TRUSS MANUFACTURER


1. Trusses to be 24" O.C.
2. Attic access min 22 1/2" x 30" were most convenient. For all areas greater than 30"
3. 9' ceilings with vaults where possible
4. Install all trusses as per truss manufacturer installation guidelines.
5. See layout for Pitch

John Davidson

CHK'D BY
DATE

REVISIONS

JOB NO.

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

6
OF

11

2.

3.

4.
5.
6.
7.
8.
9.
10.
11.
12.

Minimum header sizes shall be according to the following table unless otherwise noted.
Header sizes (single story construction)
2'-0" to 4'-0" Span 2-2x4's
4' + to 6'-0" Span 2-2x6's
6' + to 8'-0" Span 2-2x8's
8' + to 10'-0" Span 2-2x10's
10' + to 12'-0" Span 2-2x12's
Header sizes (two story construction)
2'-0" to 3'-0" Span 2-2x4's
3' + to 5'-0" Span 2-2x6's
5' + to 7'-0" Span 2-2x8's
7' + to 8'-0" Span 2-2x10's
Brace all exterior walls and cross-stud partitions at each end of building and at least every
25' of length by one of the following:
a.
Simpson WB 126 wall bracing with 3-16d nails at each end and 1-8d nails at each stud.
b.
Plywood sheathing of a minimum thickness of 3/8 inch.
Fire stopping:
a.
Fireblock stud spaces over 10' in height, furred spaces, soffits, drop ceilings, cove ceilings,
stair stringers at top and bottom of run, bearing walls and ceiling joist lines, etc.
Firestopping shall consist of 2" nominal lumber.
b.
Firestop openings around vents, pipes, ducts, chimneys, and fireplaces at ceiling
and floor levels with approved noncombustible materials.
CDX plywood is not approved where exposed to weather, i.e., roof overhangs.
Exterior wall framing to be 2"x6" studs at 16" o.c. Interior wall, framing at non-bearing walls
to be 2"x4" studs at 24" o.c. and at bearing walls 2"x4" studs at 16" o.c. with double top plate.
Shear wall to be 3/8" CDX plywood applied horizontally.
All stress grade lumber shall comply with WCLA specs and bear approval stamp on all pieces in place.
Framing lumber shall be Douglas Fir construction grade Fb 1450 or better unless otherwise noted.
Nailing to be per current U.B.C. unless otherwise noted.
All bearing partitions shall have double top plates.
Structural glued laminated timbers to be stamped by an approved agency.
Use redwood or pressure treated sole plates at all exterior walls.

FULL HOUSE
FRAMING SECTION
SCALE 1/8"=1'

CLIENT
DATE

07/18/2004

DRWN BY

John Davidson

CHK'D BY

Floor Framing:
1.
2.
3.
4.
5.
6.
7.
8.
9.

All floor joist to be Douglas Fir #2 or T.J.I. @ 16" o.c. unless otherwise noted.
For spans and dimensions refer to floor plans.
Use Simpson H 2.5 hurricane anchors at each floor joist to bearing wall connection.
Solid blocking between joists over all bearing walls, and midspans such blocking shall
be 2" minimum thickness and full depth of joists.
Minimum header sizes shall be according to the header size table unless otherwise noted.
Basis of design: floor live load of 40 psf, and floor dead load of 15 psf.
Floor decking to be " thick T & G wafer board.
Joist hangers to be Simpson U210 or equal unless otherwise noted.
Double joists and or double blocking at all interior walls.

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

Residential Design
1.

SDS-CAD
Specialized Design Systems

General framing: (Douglas Fir)

DATE

REVISIONS

JOB NO.

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

7
OF

11

CONCRETE WITH 1/2" EXPANSION

BOLTS - ANCHORED TO FLOOR DECKING


WITH 6 - 16d NAILS.
C 11x9/8" PARTICLE BOARD TREAD
WITH 1" MIN. NOSING
D 1"x8" #2 PINE RISER

A
G

E 2x6 LEDGER SECURED TO EACH STUD

WITH 2 - 16d NAILS.

F HANDRAIL/GUARDRAIL - FINAL STYLE, MATERIAL

AND COLOR TO BE OWNER'S CHOICE.


DESIGN TO BE PER CURRENT U.B.C.:
1. GUARDRAILS TO BE 36" HIGH MIN.
2. HANDRAILS TO BE 34" TO 38" ABOVE
NOSING OF TREAD

3. OPEN RAILING TO HAVE INTERMEDIATE


RAILS OR ORNAMENTAL PATTERN SUCH
THAT A SPHERE 4" ROUND CANNOT

Kitchen layout and cabinets to be chosen by


homeowner/Contractor basic layout for reference only. Measure
after sheetrock is installed for correct sizing.

PASS THRU.
G 5/8" TYPE "X" DRYWALL REQUIRED UNDER
STAIRS AND ALONG STAIR WELL WALLS.

STAIR DETAIL

Residential Design

DESCRIPTION
UTIL CAB
UTIL CAB
CRNR BASE CAB
BATH BASE CAB
KIT. BASE CAB
GAR. BASE CAB
CRNR WALL CAB
KIT. WALL CAB
KIT. WALL CAB
UTIL CAB
KIT. BASE CAB
KIT. BASE CAB
BATH BASE CAB
PEN BASE CAB

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

B 2x6 KICK PLATE - ANCHORED TO

QTY
1
1
1
1
2
1
2
1
1
1
1
1
2
1

SDS-CAD
Specialized Design Systems

A 2x12 STRINGER -3 EACH REQUIRED

NUMBER
C01
C02
C03
C04
C05
C06
C07
C08
C09
C10
C11
C12
C13
C14

CABINET SCHEDULE
FLOOR DIMENSIONS
1
93X18X84 "
1
54X18X84 "
1
36X36X36 "
1
33X24X36 "
1
30X24X36 "
1
30X27X36 "
1
24X24X30 "
1
12X12X30 "
1
33X12X15 "
1
66X18X84 "
1
36X24X36 "
1
33X24X36 "
1
36X24X36 "
0
24X24X36 "

3'-8"
D
/W

STAIR SPECIFICATIONS
1.
Stairs to be constructed with the following materials:
2x6 kick plate anchor to concrete with expansion type anchor bolts,
2x12 treads nosing 1 1/8" minimum, 3-2x12 stringers required,
2x12 blocking, " wafer board risers and 2x6 ledger.
2.
Handrail/Guardrails final style, material and color to be owner's choice. Design to be per code.
3.
Guardrails to be 42" high minimum from floor.
4.
Handrails to be 34"-38" above tread nosing.
5.
Open railing to have intermediate rails or ornamental pattern such that a sphere 4" round cannot pass through.
6.
Minimum stair requirements: maximum 8" rise, minimum 42" width, minimum 9" run, minimum head clearance 6'-8".
7.
Preferred stair requirements: rise 7" to 7 ", run 11" to 12", minimum head clearance 7'-0".
8.
Garage entrance stairs may be concrete or wood as per contractor/homeowner

3040

STAIR DETAILS

CLIENT
DATE

07/18/2004

DRWN BY

John Davidson

CHK'D BY
DATE

8' Wall

REVISIONS

5'-8"
JOB NO.

Cabinet Detail
SCALE 1/4"=1'

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

8
OF

11

Oval Spa

Square

BD3636

BD3636

UD9384
x18

SD

D
6
13
L2

CW2430

D
PB

UD5484
x18

336
PBD3

3 3 3

SD

BS3636

W3315

BD3336

DN
WL1230

BD
30
36

CBD3636
CW2430

Standard 60" (right)

x27

Standard

BS3036

BD3036

/W
3

SD

3 3

3
3

3
3

WP

DN

Garage Door Opener

x18

UD6684

Standard

NUMBER
E01
E02
E03
E04
E05
E06
E07
E08
E09
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21

QTY
6
2
22
3
34
1
15
1
12
5
27
1
1
1
2
1
2
3
4
1
3

FLOOR
0
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
1
0
1
1

ELECTRICAL SCHEDULE
DIMENSIONS
DESCRIPTION
16X16X4 "
HALF DOME
12X12X1 "
EXHAUST
16X16X4 "
HALF DOME
3X0X5 "
220V
3X0X5 "
DUPLEX
3X1X5 "
DUPLEX (WEATHERPROOF)
3X1X5 "
SINGLE POLE
3X1X5 "
DUPLEX (WEATHERPROOF) - COLOR LIGHT GRAY (MATTE)
3X1X5 "
THREE WAY
6X9X13 "
PORCH LANTERN
3X0X5 "
DUPLEX
16X8X8 "
HALF CONE - LIGHTING GREY
3X0X5 "
GFCI
9X9X18 "
CAGED LANTERN
3X1X5 "
SINGLE POLE
16X16X4 "
HALF DOME LIGHT - LIGHTING GREY
3X1X5 "
THREE WAY
6X6X2 "
SMOKE DETECTOR
6X6X2 "
SMOKE DETECTOR
9X9X18 "
CAGED LANTERN
16X16X4 "
HALF DOME LIGHT - LIGHTING GREY

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

WP

Residential Design

DN

SDS-CAD
Specialized Design Systems

Electrical Systems:
1.
Inspection is required prior to backfill of lines.
2.
Provide 20 ft. of No. 4 copper wire as ground electrode in foundation footing.
3.
Bond interior piping system with #8 bare copper.
4.
Provide main jumping bond with #4 bare copper.
5.
Electrical service is to be 200 amp service, 120/240 volt, 1 phase raintight, underground.
6.
Provide separate 20 amp circuits to washer.
7.
Provide 20 amp circuits to family and dining room, and a minimum of two 20 amp circuits to kitchen.
8.
Prewire for TV, telephone in kitchen, family room, living room, and in every bedroom.
9.
Install ground fault current interrupter on exterior, garage, kitchen, and bathroom convenience outlets.
10.
Bottom half of outlet controlled by switch when shown.
11.
All outlets in kitchen are to be at +44" excluding those for the refrigerator, range, disposal, and dishwasher.
12.
Maximum spacing of outlets shall not exceed 12 ft. along wall line and at any wall over
24" wide in all rooms except kitchen, bath, utility, and garage.
13.
Install light in walk-in closet 18" minimum horizontal from any shelf.
14.
Provide a ventilation fan capable of producing a change of air every 12 minutes for bath or utility.
15.
Provide smoke detector alarm conforming to Section 1210(A) U.B.C. and local building codes
in every bedroom and on each floor.
16.
CO2 Detector on each floor.

CLIENT
Garage Door Opener

DATE

07/18/2004

DRWN BY

John Davidson

CHK'D BY
DATE

REVISIONS

MAIN FLOOR ELECTRICAL PLAN


SCALE 1/8"=1'

JOB NO.

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

9
OF

11

SYMBOL

DESCRIPTION

Residential Design

ELECTRICAL LEGEND
3

METER SOCKET

PANEL BOX

BEDROOM
12'-0" x 14'-5"

FAMILY

SD

CEILING FAN W/ LIGHT

25'-6" x 17'-2"
SD

FLUORESCENT LIGHT FIXTURE

110V CEILING LIGHT FIXTURE


110V RECESSED LIGHT FIXTURE

BATH

UP

10'-5" x 5'-4"

110V EAVE LIGHT FIXTURE

SD

GFCI

110V CHANDILIER LIGHT FIXTURE

STORAGE

UTILITY

110V WALL LIGHT FIXTURE

15'-1" x 11'-2"

8'-7" x 7'-5"

SINGLE POLE SWITCH


WH

SD

BEDROOM
STORAGE

DM

10'-11" x 10'-11"

THREE WAY SWITCH


FOUR WAY SWITCH
DIMMER SWITCH

WP

6'-7" x 8'-7"

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

10'-5" x 12'-3"

SDS-CAD
Specialized Design Systems

BEDROOM

OUTDOOR SWITCH
110V DUPLEX RECEPTACLE
GFI

WP

110V DUPLEX RECEPTACLE


GROUND FAULT INTERUPTED
110V DUPLEX RECEPTACLE
W/ WEATHERPROOF COVER
110VFLOOR MOUNTED
DUPLEX RECEPTACLE

GARAGE
30'-2" x 23'-4"

240V RECEPTACLE
TELEPHONE JACKS
TV

Basement is to be unfinished so
electrical is to be done as minimum
required for unfinished space.
Allow Breaker box size and access
to allow for future basement
completion

TELEVISION JACKS
DOOR BELL PUSH BUTTON

SD

THERMOSTAT
SMOKE DETECTOR

CLIENT
DATE

07/18/2004

EXHAUST FAN
DC

DRWN BY

DOOR CHIME

John Davidson

CHK'D BY

F
A

FIRE ALARM PANEL

COMPUTER POINT

DATE

REVISIONS

BASEMENT ELECTRICAL PLAN


SCALE 1/8"=1'

JOB NO.

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

10
OF

11

VERT. #4 REBAR
@ 24" O.C.

NAILED
PORTION

SEE OTE
TN
F OO
NO.5

13 1/2"

SINGLE POUR
CORNER
INSTALLATION

ONE #4
REBAR IN
SHEAR CONE

MIN.
1/2"
M
FRO ER
N
COR

Simpson Strong-Tie
HPAHD

30" MINIMUM
REBAR LENGTH

12" MINIMUM
REBAR LENGTH

CORNER
DISTANCE
FROM EDGE
OF STRAP TO
CORNER

Simpson Strong-Tie
HPAHD

COMPACTED SOIL

8" MIN. THICKNESS


CONCRETE WALL

5/8" Min ROOF DECKING


ONE #4
REBAR IN
SHEAR CONE

4" COMPACTED GRAVEL

HORIZONTAL REBAR # 4
@24" O.C. W/FIRST BAR
PLACED 4" ABOVE FOOTING
& LAST BAR 4" BELOW TOP
OF FOUNDATION WALL.

J-BAR DOWELS TO MATCH


VERTICAL REBAR SPACING.
EXTENDED 24" MIN. INTO
FOUNDATION WALL. WITH
6" MIN. HOOK

ENGINEERED TRUSSES
VENT PER CODE VENTILATION

12
See
Elevation
views

METAL DRIP EDGE


RAIN GUTTERS

2- #4 REBAR CONTINUOUS

GARAGE WALL SECTION


R38 ATTIC INSULATION
ENGINEERED TRUSSES 24" O.C

2 x 6 SUB FASCIA
12" METAL FASCIA

4" CONC. SLAB

1/2"X10" FOUNDATION BOLTS

20"X10" CONC. FOOTING

2- #4 REBAR CONTINUOUS

1 FT. OVERHANG
METAL VENTED SOFFIT

R19 WALL INSULATION


EXT. WALL FINISH AS PER ELEVATIONS
TYVEK HOUSE WRAP
7/16 MIN WALL SHEATHING

PANEL SHEATHING USED AS CORNER


BRACING W/ LONG DIMENSION
PARALLEL TO STUDS

FINISH FLOOR

2 x 6 FRAMING 16 O.C.
LEAVE 1/4" GAP @
EDGES & 1/8" GAP
@ ENDS UNLESS
OTHERWISE RECOMMENDED BY
MANUFACTURER

A-307 ANCHOR BOLTS

WALL FRAMING

FOAM SILL SEAL

SHEETROCK WALL FINISH

9'
9' ROOM HEIGHT
(FROM SUB FLOOR TO FRAMING)

3/4 T&G SUB FLOOR


1 3/4 x 11 7/8" I-JOISTS OR EQUIV
R19 JOIST INSULATION

2 x 6 TREATED SILL PLATE

GRADE 2 % MIN. SLOPE

8"

CDX PLYWOOD SHEAR WALL INSTALLED W/ LONG


DIMENSION ACROSS STUDS. STAGGER VERTICAL
JOINTS

BEARING WALL SECTION

VAPOR BARRIER
80" TOP WINDOW HEIGHT
(FROM SUB FLOOR)

P O Box 374 Mendon, Utah www.sdscad.com email: sdscad@pcu.net

30# ROOFING PAPER

SDS-CAD
Specialized Design Systems

SINGLE POUR
RIM JOIST
INSTALLATION

4" CONC. SLAB

8"

GRADE 2 % MIN. SLOPE


ASPHALT SHINGLES ROOFING MATERIAL

Residential Design

@32" MAX. SPACING. BOLTS


SHALL BE EMBEDDED 7" MIN.

HD1 = HPAHD22 Simpson Hold Downs


HD2 = STHD14RJ Simpson Hold Downs

@32" MAX. SPACING. BOLTS


SHALL BE EMBEDDED 7" MIN.

6" MIN TO GRADE HEIGHT


SIDING MATERIAL

TYPICAL SHEAR WALL


N.T.S.

06A-1038

VAPOR BARRIER

8" FOUNDATION WALL


A-615 RE-BAR 24" OC VERT & HOR

9'-0"

R13 WALL INSULATION

WATERPROOFING TO GRADE
10d NAILS @ 6" O.C. AT EDGES
& SEAMS AND 10d NAILS @ 12"
O.C. IN FIELD U.N.O. ON SHEAR
WALL SCHEDULE

VERTICAL REBAR #4
@24 O.C.

2 x 4 WALL FRAMING

GRADE

8'

SHEETROCK WALL FINISH

8'-8" ROOM HEIGHT


(FROM SLAB TO FRAMING)

4" CONCRETE FLOOR


WIRE MESH

4" DRAIN TILE

J-BAR DOWELS TO MATCH


VERTICAL REBAR SPACING.
EXTENDED 24" MIN. INTO
FOUNDATION WALL. WITH
6" MIN. HOOK

4" GRAVEL FILL

A-615 RE-BAR

HORIZONTAL REBAR # 4
@24" O.C. W/FIRST BAR
PLACED 4" ABOVE FOOTING
& LAST BAR 4" BELOW TOP
OF FOUNDATION WALL.
4" CONC. SLAB
4" GRAVEL

VAPOR BARRIER

10" x 20" MIN


CONCRETE FOOTING

8" MIN. THICKNESS

10"X20" CONC.
FOOTINGS

COMPACTED SOIL
2- #4 REBAR CONTINUOUS

CLIENT
DATE

07/18/2004

DRWN BY

John Davidson

CHK'D BY
DATE

ONE STORY WALL SECTION STANDARD PLATFORM FRAMING

BASEMENT WALL SECTION

REVISIONS

SCALE:NO SCALE

JOB NO.

SHEET NO.

Note: Paper size D - 22 x 34 scale is as stated if printed on 11 x 17 B size scale is 1/2

@COPYRIGHT SDSCAD Specialized Design Systems

11
OF

11

Beam Calculations

BEAM AND FLOOR CALCULATIONS


Floor Joist[ 2000 International Residential Code (97 NDS) ] Ver: 5.05
Project: - Location: Floor Joists
Summary:
1.5 IN x 11.25 IN x 18.0 FT @ 16 O.C. / Select Structural - Douglas Fir-Larch - Dry Use
Section Adequate By: 17.2% Controlling Factor: Moment of Inertia / Depth Required 10.67 In
Center Span Deflections:
Dead Load:
DLD-Center= 0.14 IN
Live Load:
LLD-Center= 0.37 IN = L/580
Total Load:
TLD-Center= 0.51 IN = L/422
Center Span Left End Reactions (Support A):
Live Load:
LL-Rxn-A= 480 LB
Dead Load:
DL-Rxn-A= 180 LB
Total Load:
TL-Rxn-A= 660 LB
Bearing Length Required (Beam only, Support capacity not checked):BL-A=0.70IN
Center Span Right End Reactions (Support B):
Live Load:
LL-Rxn-B= 480 LB
Dead Load:
DL-Rxn-B= 180 LB
Total Load:
TL-Rxn-B= 660 LB
Bearing Length Required (Beam only, Support capacity not checked):BL-B=0.70IN
Joist Data:
Center Span Length:
L2= 18.0 FT
Floor sheathing applied to top of joists-top of joists fully braced.
Live Load Duration Factor:
Cd= 1.00
Live Load Deflect. Criteria:
L/ 480
Total Load Deflect. Criteria:
L/ 360
Center Span Loading:
Uniform Floor Loading:
Live Load:
LL-2= 40.0 PSF
Dead Load:
DL-2= 15.0 PSF
Total Load:
TL-2= 55.0 PSF
Total Load Adjusted for Joist Spacing: wT-2= 73 PLF
Properties For: Select Structural- Douglas Fir-Larch
Bending Stress:
Fb= 1500 PSI
Shear Stress:
Fv= 95 PSI
Modulus of Elasticity:
E= 1900000 PSI
Stress Perpendicular to Grain:
Fc-perp= 625 PSI
Adjusted Properties
Fb' (Tension):
Fb'= 1725 PSI
Adjustment Factors: Cd=1.00 Cf=1.00 Cr=1.15
Fv':
Fv'= 95 PSI
Adjustment Factors: Cd=1.00
Design Requirements:
Controlling Moment:
M= 2970 FT-LB
9.0 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads on span(s) 2
Controlling Shear:
V= 660 LB
At left support of span 2 (Center Span)
Critical shear created by combining all dead loads and live loads on span(s) 2
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq= 20.66 IN3
S= 31.64 IN3
Area (Shear):
Areq= 10.42 IN2
A= 16.88 IN2
Moment of Inertia (Deflection):
Ireq= 151.91 IN4
I= 177.98 IN4
Combination Roof and Floor Beam[ 2000 International Residential Code (97 NDS) ] Ver: 5.05
Project: - Location: 16 Garage Door Header
Summary:
( 2 ) 1.75 IN x 14.0 IN x 14.0 FT / Versa-Lam 2800 Fb DF - Boise Cascade
Section Adequate By: 42.0% Controlling Factor: Section Modulus / Depth Required 12.36 In
* Laminations are to be fully connected to provide uniform transfer of loads to all members
Deflections:
Dead Load:
DLD= 0.14 IN
Live Load:
LLD= 0.32 IN = L/524
Total Load:
TLD= 0.47 IN = L/361
Reactions (Each End):
Live Load:
LL-Rxn= 4160 LB
Dead Load:
DL-Rxn= 1872 LB
Total Load:
TL-Rxn= 6032 LB
Bearing Length Required (Beam only, Support capacity not checked):BL=1.92IN
Beam Data:
Span:
L= 14.0 FT
Maximum Unbraced Span:
Lu= 1.5 FT
Live Load Deflect. Criteria:
L/ 360
Total Load Deflect. Criteria:
L/ 240
Roof Loading:
Roof Live Load-Side One:
RLL1= 30.0 PSF
Roof Dead Load-Side One:
RDL1= 15.0 PSF
Roof Tributary Width-Side One:
RTW1= 7.81 FT
Roof Live Load-Side Two:
RLL2= 30.0 PSF
Roof Dead Load-Side Two:
RDL2= 15.0 PSF
Roof Tributary Width-Side Two:
RTW2= 0.0 FT
Roof Duration Factor:
Cd-roof= 1.15
Floor Loading:

1 of 3

Beam Calculations
Floor Live Load-Side One:
FLL1= 40.0 PSF
Floor Dead Load-Side One:
FDL1= 15.0 PSF
Floor Tributary Width-Side One:
FTW1= 9.0 FT
Floor Live Load-Side Two:
FLL2= 40.0 PSF
Floor Dead Load-Side Two:
FDL2= 15.0 PSF
Floor Tributary Width-Side Two:
FTW2= 0.0 FT
Floor Duration Factor:
Cd-floor= 1.00
Wall Load:
WALL=
0 PLF
Beam Loads:
Roof Uniform Live Load:
wL-roof= 234 PLF
Roof Uniform Dead Load (Adjusted for roof pitch):wD-roof=117PLF
Floor Uniform Live Load:
wL-floor= 360 PLF
Floor Uniform Dead Load:
wD-floor= 135 PLF
Beam Self Weight:
BSW= 15 PLF
Combined Uniform Live Load:
wL= 594 PLF
Combined Uniform Dead Load:
wD= 252 PLF
Combined Uniform Total Load:
wT= 862 PLF
Controlling Total Design Load:
wT-cont= 862 PLF
Properties For: Versa-Lam 2800 Fb DF- Boise Cascade
Bending Stress:
Fb= 2800 PSI
Shear Stress:
Fv= 285 PSI
Modulus of Elasticity:
E= 2000000 PSI
Stress Perpendicular to Grain:
Fc_perp= 900 PSI
Adjusted Properties
Fb' (Tension):
Fb'= 3146 PSI
Adjustment Factors: Cd=1.15 Cl=0.99 Cf=0.98
Fv':
Fv'= 328 PSI
Adjustment Factors: Cd=1.15
Design Requirements:
Controlling Moment:
M= 21113 FT-LB
7.0 ft from left support
Critical moment created by combining all dead and live loads.
Controlling Shear:
V= 6032 LB
At support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq= 80.53 IN3
S= 114.33 IN3
Area (Shear):
Areq= 27.61 IN2
A= 49.00 IN2
Moment of Inertia (Deflection):
Ireq= 550.29 IN4
I= 800.33 IN4
Combination Roof and Floor Beam[ 2000 International Residential Code (97 NDS) ] Ver: 5.05
Project: 9'Door - Location: 9' Garage Door Header
Summary:
( 2 ) 1.75 IN x 11.875 IN x 9.0 FT / Versa-Lam 2800 Fb DF - Boise Cascade
Section Adequate By: 25.9% Controlling Factor: Area / Depth Required 10.2 In
* Laminations are to be fully connected to provide uniform transfer of loads to all members
Deflections:
Dead Load:
DLD= 0.07 IN
Live Load:
LLD= 0.17 IN = L/638
Total Load:
TLD= 0.24 IN = L/446
Reactions (Each End):
Live Load:
LL-Rxn= 5040 LB
Dead Load:
DL-Rxn= 2172 LB
Total Load:
TL-Rxn= 7212 LB
Bearing Length Required (Beam only, Support capacity not checked):BL=2.29IN
Beam Data:
Span:
L= 9.0 FT
Maximum Unbraced Span:
Lu= 1.5 FT
Live Load Deflect. Criteria:
L/ 360
Total Load Deflect. Criteria:
L/ 240
Roof Loading:
Roof Live Load-Side One:
RLL1= 40.0 PSF
Roof Dead Load-Side One:
RDL1= 15.0 PSF
Roof Tributary Width-Side One:
RTW1= 14.0 FT
Roof Live Load-Side Two:
RLL2= 40.0 PSF
Roof Dead Load-Side Two:
RDL2= 15.0 PSF
Roof Tributary Width-Side Two:
RTW2= 14.0 FT
Roof Duration Factor:
Cd-roof= 1.15
Floor Loading:
Floor Live Load-Side One:
FLL1= 40.0 PSF
Floor Dead Load-Side One:
FDL1= 15.0 PSF
Floor Tributary Width-Side One:
FTW1= 0.0 FT
Floor Live Load-Side Two:
FLL2= 40.0 PSF
Floor Dead Load-Side Two:
FDL2= 15.0 PSF
Floor Tributary Width-Side Two:
FTW2= 0.0 FT
Floor Duration Factor:
Cd-floor= 1.00
Wall Load:
WALL=
0 PLF
Beam Loads:
Roof Uniform Live Load:
wL-roof= 1120 PLF
Roof Uniform Dead Load (Adjusted for roof pitch):wD-roof=470PLF
Floor Uniform Live Load:
wL-floor=
0 PLF
Floor Uniform Dead Load:
wD-floor=
0 PLF
Beam Self Weight:
BSW= 13 PLF
Combined Uniform Live Load:
wL= 1120 PLF
Combined Uniform Dead Load:
wD= 470 PLF
Combined Uniform Total Load:
wT= 1603 PLF
Controlling Total Design Load:
wT-cont= 1603 PLF
Properties For: Versa-Lam 2800 Fb DF- Boise Cascade
Bending Stress:
Fb= 2800 PSI

2 of 3

Beam Calculations
Shear Stress:
Fv= 285 PSI
Modulus of Elasticity:
E= 2000000 PSI
Stress Perpendicular to Grain:
Fc_perp= 900 PSI
Adjusted Properties
Fb' (Tension):
Fb'= 3207 PSI
Adjustment Factors: Cd=1.15 Cl=0.99 Cf=1.00
Fv':
Fv'= 328 PSI
Adjustment Factors: Cd=1.15
Design Requirements:
Controlling Moment:
M= 16226 FT-LB
4.5 ft from left support
Critical moment created by combining all dead and live loads.
Controlling Shear:
V= 7212 LB
At support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq= 60.71 IN3
S= 82.26 IN3
Area (Shear):
Areq= 33.00 IN2
A= 41.56 IN2
Moment of Inertia (Deflection):
Ireq= 275.52 IN4
I= 488.41 IN4

3 of 3

_________________
Permit Number
_________________

MECcheck Compliance Report


1995 MEC

Checked By/Date

MECcheck Software Version 3.3 Release 1b


Data filename: B:\clay & Mandy Davis\clay.cck
TITLE: Clay Davis Providence
CITY: Logan
STATE: Utah
HDD: 7389
CONSTRUCTION TYPE: Single Family
DATE: 06/29/04
DATE OF PLANS: June 29, 2004
COMPLIANCE: Passes
Maximum UA = 333
Your Home = 327
1.8% Better Than Code
Gross
Glazing
Area or Cavity Cont.
or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Vinyl Frame, Double Pane with Low-E
Door 1: Solid
Basement Wall 1:
Solid Concrete or Masonry, 8.0' ht/7.0' bg/8.0' insul
Window 2: Vinyl Frame, Double Pane with Low-E
Door 2: Solid
Furnace 1: Forced Hot Air, 90 AFUE
Air Conditioner 2: Electric Central Air, 10 SEER

1602
1351
152
134

0.0
0.0

1351
80
21

0.0

38.0
19.0
0.350
0.350

40
88
53
47

0.350
0.350

64
28
7

13.0

COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with
the permit application. The proposed building has been designed to meet the 1995 MEC requirements in MECcheck Version 3.3 Release 1b and to comply with the
mandatory requirements listed in the MECcheck Inspection Checklist.
Builder/Designer___________________________________________

Date_______________

MECcheck Inspection Checklist


1995 MEC
MECcheck Software Version 3.3 Release 1b
DATE: 06/29/04
TITLE: Clay Davis Providence
Bldg. |
Dept. |
Use |
|
|
[ ] |
|
|
|
[ ] |
|
|
|
[ ] |
|
|
|
|
[ ] |
|
|
|
[ ] |
|
|
|
|
|
[ ] |
|
[ ] |
|
|
|
[ ] |
|
[ ] |
|
|
|
[ ] |
|
[ ] |
|
|
|
|
[ ] |
|
|
[ ] |
[ ] |
|
[ ] |
|
|
|
[ ] |
|
|
|
[ ] |
|
[ ] |
|
|
[ ] |
|
|
|
[ ] |
|
|
[ ] |
|
|
|
[ ] |
|

Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 continuous insulation
Comments: ______________________________________________________________
Above-Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-19.0 continuous insulation
Comments: ______________________________________________________________
Basement Walls:
1. Basement Wall 1: Solid Concrete or Masonry, 8.0' ht/7.0' bg/8.0' insul,
R-13.0 continuous insulation
Comments: ______________________________________________________________
Windows:
1. Window 1: Vinyl Frame, Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
# Panes____ Frame Type____________ Thermal Break? [ ] Yes [ ] No
Comments: ______________________________________________________________
2. Window 2: Vinyl Frame, Double Pane with Low-E, U-factor: 0.350
For windows without labeled U-factors, describe features:
# Panes____ Frame Type____________ Thermal Break? [ ] Yes [ ] No
Comments: ______________________________________________________________
Doors:
1. Door 1: Solid, U-factor: 0.350
Comments: ______________________________________________________________
2. Door 2: Solid, U-factor: 0.350
Comments: ______________________________________________________________
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 90 AFUE or higher
Make and Model Number __________________________________________
2. Air Conditioner 2: Electric Central Air, 10 SEER or higher
Make and Model Number __________________________________________
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be Type IC rated and installed with no penetrations, or Type IC or non-IC
rated installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible
materials and 3" clearance from insulation.
Vapor Retarder:
Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors.
Materials Identification:
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All ducts must be sealed with mastic and fibrous backing tape. Pressure-sensitive tape may be used
for fibrous ducts. Duct tape is not permitted.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 120 F or chilled fluids below 55 F must be insulated to the
levels in Table 2.

Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.


Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non-Circulating Runouts
Circulating Mains and Runouts
Temperature ( F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types
Range ( F)
2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5

NOTES TO FIELD (Building Department Use Only)


____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90

ID
General
GN1
GN2
GN3
GN4
GN5
GN6
GN7
GN8
GN9
GN10
GN11
GN12
GN13
GN14
GN15
GN16
GN17
GN18
GN19
GN20
GN21
GN22
GN23
GN24
GN25
GN26
GN27
GN28

Sub Cat

Flr
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2

Size

Description

36 high wall
104 high wall
108 high wall
106 1/2 high wall
94 1/2 high wall
34 1/2 high wall
82 high wall
108 high wall
36 high wall
108 high wall
18W18D
108 high wall
137 1/8 high wall
108 high wall
82 15/16 high wall
108 high wall
108 high wall
130 high wall
133 1/2 high wall
120 high wall

8" Concrete Stem Wall


Frame-3 1/2
8" Concrete Stem Wall
8" Concrete Stem Wall
8" Concrete Stem Wall
8" Concrete Stem Wall
Frame-3 1/2
Frame-3 1/2
Frame-3 1/2
Interior-4
Trapezoid
Siding-6
Copy of Stucco-6
Copy of Stucco-6
Copy of Stucco-6
Stucco-6
Interior-4
Fire-6
Fire-6
Interior-4
heated ceiling area
heated wall area
heated glass area
heated door area
82 1/4 high wall
Copy of Stucco-6
1 7/16 high wall
Copy of Stucco-6
103 9/16 high wall Copy of Stucco-6
30 15/16 high wall Copy of Stucco-6

Count
33
27
18
136
31
24
1
15
10
32
4
137
18
38
11
2
131
6
31
8
2344.00
1347.00
140.00
40.00
6
20
26
18

Extra

Unit

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.00
0.00
0.00
0.00
0
0
0
0

Price

ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
sq ft
sq ft
sq ft
sq ft
ft
ft
ft
ft
Subtotal:

Foundation
FO1
FO2
FO3
FO4
FO5
FO6
FO7
FO8
FO9
FO10
FO11

0
0
0
0
0
0
0
0
0
0
0

8" thick
1/2x6"
18x8"h
no. 4
no. 4
no. 4
16x8"h
4x8"
2165 sq ft
2165 sq ft

Concrete Grey
foam sill seal
foundation bolts
concrete footing
rebar (footing)
horiz. rebar (wall)
vert. rebar (wall)
concrete footing
foundation girder
concrete slab
steel mesh for slab

38.93
289
64
8.98
577
3696
1510
1.54
10
26.73
2165.00

0.00
0
0
0.00
0
0
0
0.00
0
0.00
0.00

cu yd
ft
cu yd
ft
ft
ft
cu yd
ft
cu yd
sq ft
Subtotal:

Subfloor
SF1
SF2
SF3
SF4
SF5
SF6
SF7
SF8
SF9
SF10
SF11
SF12
SF13
SF14
SF15
SF16
SF17

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

4'x8'x3/4"
2x6"-16'+
2x12"-16'+
2x12"-12'
2x12"-10'
2x12"-30'
2x12"-22'
2x12"-28'
2x12"-36'
2x12"-16'+
2x12"-16'+
2x6"-16'+
2x6"-12'
2x6"-18'
2x6"-24'
2x6"-36'
2x6"-30'

Sheet Plywood
mudsill - lumber
rim joists - lumber
rim joists - lumber
rim joists - lumber
floor joists - lumber
floor joists - lumber
floor joists - lumber
floor joists - lumber
mudsill - lumber
floor joists - lumber
ceiling joists - lumber
ceiling joists - lumber
ceiling joists - lumber
ceiling joists - lumber
ceiling joists - lumber
ceiling joists - lumber

49
191
228
1
1
18
6
4
9
178
44
14
2
7
9
9
15

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

ft
ft

ft
ft
ft

Subtotal:
Framing
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27

0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

2x4-16ft+
2x4"-99 1/2"
4x12"
2x4"-77 1/2"
2x4"-87 1/2"
2x4"-103 1/2"
2x4-31 1/2"
2x4-16ft+
2x6-16ft+
2x11-16ft+
2x6-16ft+
2x6"-103 1/2"
2x6-16ft+
2x4"-103 1/2"
2x12-16ft+
2x6-16ft+
2x6"-84 3/4"
2x6"-10 3/4"
2x4"-84 3/4"
2x4-16ft+
2x11-16ft+
2x7-16ft+
1" thick
2x6"-101 1/2"
2x4"-101 1/2"
2x6"-61 15/16"
2x6"-8 1/4"

fir plate
fir stud
door/window header
fir stud
fir stud
fir stud
Framing Fir Stud 16" OC
fir stud stock
header - lumber
header - lumber
fir plate
fir stud
fir stud stock
fir stud
header - lumber
header - lumber
fir stud
fir stud
fir stud
header - lumber
header - lumber
header - lumber
Stone Cobblefield Grey
fir stud
fir stud
fir stud
fir stud

263
25
28
6
2
42
10
51
11
11
960
70
938
150
116
82
20
8
2
16
37
138
193.00
6
1
12
24

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.00
0
0
0
0

ft
ft

ft
ft
ft
ft
ft
ft
ft

ft
ft
ft
sq ft

Tot Cost

ID
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180

F28
F29
F30
F31
F32
F33
F34
F35
F36
F37
F38
F39
F40
F41
F42
F43
F44
F45

Sub Cat

Flr
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2

Size
2x6"-35 3/4"
2x6"-50 5/8"
2x4-16ft+
2x4"-16 3/4"
2x4"-18 1/2"
2x4-16ft+
2x6"-125 1/2"
2x6"-127 1/2"
2x6"-7 1/2"
2x4"-20 1/2"
2x6"-12 3/4"
2x6-16ft+
2x6"-75 5/16"
2x6"-51 5/16"
2x6--3"
2x6-16ft+
2x4-16ft+
2x6"-25 7/16"

Description
fir stud
fir stud
fir plate
fir stud
fir stud
fir stud stock
fir stud
fir stud
fir stud
fir stud
fir stud
fir plate
fir stud
fir stud
Framing Fir Stud 16" OC
fir stud stock
header - lumber
fir stud

Count
4
6
409
7
12
162
4
8
1
3
4
203
6
1
20
175
4
9

Extra

Unit
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Price

ft

ft

ft

ft
ft
Subtotal:

Siding
S1
S2
S3
S4
S5
S6
S7

0
1
1
1
1
2
2

4'x8'x1/2"
7" wide
4'x8'x5/8"
1 1/8" thick
1 1/8" thick
4'x8'x5/8"

Sheet Sheetrock
Siding Aluminum Tan
Sheet Plywood-hrz
Siding Stucco
house wrap
Siding Stucco
Sheet Plywood-hrz

10
2260
57
9.00
5982.00
212.00
7

0
0
0
0.00
0.00
0.00
0

ft
sq ft
sq ft
sq ft
Subtotal:

Ext Trim
EX1
EX2
EX3
EX4
EX5
EX6
EX7
EX8
EX9
EX10
EX11
EX12
EX13
EX14
EX15
EX16
EX17
EX18
EX19

0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1

1x4-16ft+
1x4-16ft+
1x4-16ft+
1x8-36"
8 in
6" thick
24" thick
4" thick
1x4-16ft+
1x4-16ft+
1x4-16ft+
1x8-36"
8 in
1x4-16ft+
8 in
1x7-72"
7 in
1x7-36"

exterior sill
ext. window casing
ext. door casing
door threshold
ext. door jamb
Concrete Grey
Concrete Grey
- concrete grey
exterior sill
ext. window casing
ext. door casing
door threshold
ext. door jamb
garage door casing
garage door jamb
door threshold
ext. door jamb
door threshold
Stone Cobblefield Grey

25
70
17
1
17
0.14
0.74
0.22
45
215
55
1
17
55
55
1
38
1
78.00

0
0
0
0
0
0.00
0.00
0.00
0
0
0
0
0
0
0
0
0
0
0.00

ft
ft
ft
ft
cu yd
cu yd
cu yd
ft
ft
ft
ft
ft
ft
ft
sq ft
Subtotal:

Roofing
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
R25
R26
R27
R28
R29
R30
R31
R32
R33
R34
R35
R36
R37

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

2x8"-16'+
2x8"-14'
2x8"-16'
2x8"-10'
2x8"-24'
2x6"-16'+
2x8"-16'+
2x8"-22'
2x8"-12'
2x8"-10'
2x6"-16'
2x6"-14'
2x6"-12'
2x6"-10'
2x8"-18'
2x4"-16'+
2x8"-14'
2x8"-16'
2x6"-20'
2x6"-22'
2x6"-18'
2x8"-46'
2x6"-26'
2x6"-24'
2x8"-54'
90 deg. bend
bend to slope

4x8' sheets
2x8"
2x8"

ridge board - lumber


ridge board - lumber
ridge board - lumber
ridge board - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
rafters - lumber
valley flashing
roof/wall flashing
roof/wall flashing
ridge cap
hip ridge cap
Roofing Dimensional Comp.
roof sheathing
gable fascia
eave fascia
metal drip edge
gutter
downspout

205
1
2
1
1
186
28
1
4
1
11
22
16
10
1
19
2
3
10
4
8
2
10
2
1
54
3
10
49
125
3226.00
101
93
260
353
260
12

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.00
0
0
0
0
0
0

ft

ft
ft

ft

ft
ft
ft
ft
ft
sq ft
ft
ft
ft
ft
Subtotal:

Insulation
IN1

1 12x24x48" batts

ceiling insulation

293

Tot Cost

ID
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270

IN2

Sub Cat

Flr
Size
1 6x16x93" batts

Description
wall insulation

Count
124

Extra

Unit

Price

0
Subtotal:

Flooring
FL1
FL2
FL3
FL4

0
1 12x12x1/4
1 2 1/4" wide
1 5 1/2" wide

landing floor
Tile Tan
Flooring Oak-Golden
Deck Plank 2x6

24.00
901
2469
549

0.00 sq ft
0
0 ft
0 ft
Subtotal:

Wall Brd
WB1
WB2
WB3
WB4
WB5
WB6
WB7
WB8
WB9
WB10
WB11

0
0
0
0
1
1
1
1
1
1
2

4'x8'x1/2"
4'x8'x3/4"
4'x8'x1/2"
4'x8'x1/2"
4'x8'x5/8"
4'x8'x5/8"
4'x8'x3/4"
4'x8'x1/2"
4'x8'x1/2"

Sheet Sheetrock
Color Bone White
Sheet Sheetrock
(wp) - sheet sheetrock
Sheet Sheetrock
Sheet Plywood-hrz
Sheet Sheetrock
Color Bone White
Sheet Sheetrock
(wp) - sheet sheetrock
Sheet Sheetrock

9
2109.00
67
1
151
6
13
2120.00
98
6
7

0
0.00 sq ft
0
0
0
0
0
0.00 sq ft
0
0
0
Subtotal:

Windows
W1
W2
W3
W4
W5
W6
W7
W8
W9
W10
W11
W12
W13
W14

0
0
1
1
1
1
1
1
1
1
1
1
1
2

48x42
24x36
36x48
58x92 1/4-mu
88x92 1/4-mu
14x76
68x18
48x36
48x48
36x60
40x72
48x42
24x30
20x20

left sliding
double hung
awning
mulled unit
mulled unit
fixed glass
fixed glass
fixed glass
right sliding
double hung
fixed glass
right sliding
double hung
24x24 Octagon

5
1
1
1
1
2
1
1
1
2
2
1
1
2

0
0
0
0
0
0
0
0
0
0
0
0
0
0
Subtotal:

Doors
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
D17
D18
D19
D20
D21
D22
D23
D24
D25
D26

0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

36x80x1 3/4R
30x80x1 3/8L
30x80
36x80x1 3/4R

192x96
108x84
24x80
30x80x1 3/8L
36x80x1 3/8L
30x80x1 3/8R
20x80x1 3/8R
46x80
30x80x1 3/8
36x80x1 3/4R
36x80x1 3/4L
36x80x1 3/4L

handle: Lever (decorative)


handle: Exterior Handle (ext.)
lock: Dead Bolt (interior)
lock: Dead Bolt (exterior)
hinge: hidden
ext. hinged-glass
3 Panel Door - color brite white
bifold
ext. 6-Panel
handle: Lever (decorative)
handle: Exterior Handle (ext.)
lock: Dead Bolt (interior)
lock: Dead Bolt (exterior)
hinge: hidden
garage 4-Panel (long)
garage 2-Panel
bifold
3 Panel Door - color brite white
3 Panel Door - color brite white
3 Panel Door - color brite white
3 Panel Door - color brite white
bifold
pocket
ext. hinged-glass
ext. hinged-glass
ext. 6-Panel

1
1
1
1
7
1
2
1
1
4
4
4
4
26
1
1
1
2
1
3
1
1
1
1
1
1

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Subtotal:

Cabinets
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

21W1D
BD3336
31x6"

BD3636
34x6"
UD9384x18
BLUD6484x18
UD5484x18
BS3036x27
28x6"

CBD3636
10 1/4x6"

BD3036
28x6"

RP-2-REC
hidden cab. hinge
bath base cab
bath cab. drawer
countertop - countertop pepper
front cap (bath)
backsplash (bath)
bath base cab
bath cab. drawer
util cab
util cab
util cab
gar. base cab
utility cab. drawer
countertop - countertop pepper
front cap (utility)
backsplash (utility)
crnr base cab
kit. cab. drawer
countertop - countertop pepper
front cap (kit.)
backsplash (kit.)
kit. base cab
kit. cab. drawer

36
72
2
2
18.00
11
8
1
1
1
1
1
1
1
6.00
5
2
2
4
43.00
35
16
1
1

0
0
0
0
0.00
0
0
0
0
0
0
0
0
0
0.00
0
0
0
0
0.00
0
0
0
0

sq ft
ft
ft

sq ft
ft
ft

sq ft
ft
ft

Tot Cost

ID
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360

C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36

Sub Cat

Flr
1
1
1
1
1
1
1
1
1
1
1
1

Size

PBDR2136
19x6"
PBD3336
31x6"
BS3636
34x6"
CW2430
W3315
WR1230

Description
countertop - countertop pepper
countertop front cap
pen base cab
kit. cab. drawer
pen base cab
kit. cab. drawer
kit. base cab
kit. cab. drawer
backsplash
crnr wall cab
kit. wall cab
kit. wall cab

Count
12.00
9
1
1
1
1
1
1
5
2
1
1

Extra
0.00
0
0
0
0
0
0
0
0
0
0
0

Unit
sq ft
ft

Price

ft

Subtotal:
Int Trim
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T17
T18
T19
T20
T21
T22
T23
T24
T25
T26
T27
T28
T29
T30
T31
T32
T33
T34
T35
T36
T37
T38
T39

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

1x4-16ft+
1x4-16ft+
1x4-16ft+
4 in
41 5/8x11 3/4-1"
41 5/8x7 3/4"
42 5/8x11 3/4-1"
42 5/8x7 3/4"
2" wide
1 3/16" diam.
8 treads
42 3/8x11 3/4-1"
42 3/8x7 3/4"
5 treads
2x10"
1x8"
2" square
1x4-16ft+
1x4-16ft+
1x4-16ft+
4 in
7 in
4 1/2" wide
4 1/2" wide
1 1/2" diam.
4 1/2" square
4 1/2" square
3 1/2" wide
3 1/2" wide
4" square
4" square
81 1/16x9 7/8-1"
81 1/16x7"
2 treads
38x11 5/16-1"
2" wide
1 3/16" diam.
11 treads
1x6-16ft+

window apron
sill
interior casing
interior jamb
stair tread
riser
stair tread
riser
int. railing
square baluster
stair stringer
stair tread
riser
stair stringer
landing joists - fir
landing rim trim
newel
window apron
sill
interior casing
interior jamb
interior jamb
int. railing
railing shoe
square baluster
newel
half newel
int. railing
railing shoe
newel
half newel
stair tread
riser
stair stringer
stair tread
int. railing
square baluster
stair stringer
base molding

25
25
194
53
2
2
6
6
388
23
2
5
5
2
28
21
2
45
45
616
155
17
92
92
42
1
1
152
152
3
2
2
2
2
11
308
44
2
413

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

ft
ft
ft
ft

in

ft
ft
ft
ft
ft
ft
ft
in
in

in
in

in

ft
Subtotal:

Fixtures
FX1
FX2
FX3
FX4
FX5
FX6
FX7
FX8
FX9
FX10
FX11

0
0
0
1
1
1
1
1
1
1
1

31W34D
24W19D
36W36D
31W34D
49W36D
14W14D
60W36D
60W32D
23W22D
32W21D
12W108D

Standard
Free Standing (rect)
Corner Shower [36W36D]
Standard
Square
14" Round
Oval Spa
Standard 60" (right)
Single Sink [23W]
Double 32"
Garage Door Opener

1
1
1
2
1
2
1
1
1
1
2

0
0
0
0
0
0
0
0
0
0
0
Subtotal:

Appliance
A1
A2
A3
A4
A5
A6
A7

0
0
1
1
1
1
1

22W29D
20W20D
28W27D
26W27D
36W31D
24W22D
28W22D

Gas Furnace [22W29D]


Water Heater 40G
Dryer (gas)
Washer
Side-by-Side
Dishwasher [24]
Elec 30"

1
1
1
1
1
1
1

0
0
0
0
0
0
0
Subtotal:

Electrical
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13

0
0
0
0
0
0
0
0
0
1
1
1
1

wall mount
wall mount
wall mount
wall mount
wall mount
wall mount
ceiling mount
ceiling mount
ceiling mount
wall mount
wall mount
wall mount
wall mount

Duplex
Three Way
Caged Lantern
Single Pole
Half Cone - lighting grey
GFCI
Half Dome
Smoke Detector
Half Dome Light - lighting grey
220V
Duplex
Duplex (weatherproof)
Porch Lantern

27
2
1
2
1
1
6
4
1
3
32
1
5

0
0
0
0
0
0
0
0
0
0
0
0
0

Tot Cost

ID
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391

E14
E15
E16
E17
E18
E19
E20
E21

Sub Cat

Flr
1
1
1
1
1
1
1
1

Size
wall mount
wall mount
wall mount
wall mount
ceiling mount
ceiling mount
ceiling mount
ceiling mount

Description
Single Pole
Three Way
Duplex (weatherproof) - color light gra
Caged Lantern
Half Dome
Exhaust
Half Dome Light - lighting grey
Smoke Detector

Count
14
10
1
1
22
2
3
3

Extra

Unit

Price

0
0
0
0
0
0
0
0
Subtotal:

Hardware
H1
H2

1
1

bath cab drawer glide


kit. cab drawer glide

2
10

0
0
Subtotal:

Decks-Walks
DW1
DW2
DW3
DW4
DW5
DW6
DW7
DW8
DW9
DW10
DW11
DW12
DW13
DW14

1
1
1
1
1
1
1
1
1
1
1
1
1
1

3 1/2" wide
3 1/2" wide
1 1/2" square.
4" square
4" square
4" square
4" square
2x12"-20'
2x12"-16'+
2x12"-16'+
2x12"-14'
2x12"-10'
2x12"-10'
2x12"-14'

ext. railing
railing shoe
baluster
rail post
half support post
support post
half rail post
rim joists - lumber
rim joists - lumber
floor joists - lumber
rim joists - lumber
rim joists - lumber
floor joists - lumber
floor joists - lumber

52
52
113
8
1
3
2
3
33
83
3
4
7
3

0
0
0
0
0
0
0
0
0
0
0
0
0
0

ft
ft

ft
ft

Subtotal:
Total:

Tot Cost

Вам также может понравиться