Академический Документы
Профессиональный Документы
Культура Документы
Sl. No.
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
1.13
1.14
1.15
1.16
1.17
2
2.1
DESCRIPTION
METAL STRUCTURAL WORK
Poles for 220kV and 60kV Gantry
Beams for 220kV and 60kV Gantry
Frame for 220kV Line Disconnector + Earthing switch
Frame for 60kV Line Disconnector + Earthing switch
Frame for 220kV Disconnector bars
Frame for 60kV Disconnector bars
Frame for 220kV Neutral Disconnector
Frame for 60kV Neutral Disconnector
Support frame of 220kV Voltage Transformer
Support frame of 60kV Voltage Transformer
Support frame of 220kV Current transformer
Support frame of 60kV Current transformer
Support frame of 220kV and 10kV Surge Arresters
Support frame of 220kV and 60kV Busbar insulators
Support frame of Auxiliary Service Transformer
LT cables support frame, various fittings + Grating
Frame for Auxiliary Service Transformer disconnector Insulator
Rev 00
Unit
Qty
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Nos
03
2.2
Sets
03
2.3
1600A, 220kV single phase three pole circuit breakers including frame
Sets
03
Sets
01
1600A, 1-phase three pole, Short time current rating 31.5kA for 1sec,
SF6 type with Spring operating mechanism, DC motor operated,
suitable for control voltage of 127VDC, control cabinet, piping,
interpole cables, cable glands, terminal blocks, marking ferrules, lugs,
pressure gauge, density monitor, support structure, minimum creepage
distance 31mm/kV, complete as per specification.
2.4
Remarks
Sl. No.
DESCRIPTION
Unit
Qty
2.5
Sets
03
2.6
1250A, 60kV single phase three pole circuit breaker including frame
Sets
09
Sets
01
Sets
12
Sets
02
Sets
06
Sets
18
Sets
02
Sets
03
2.7
2.8
2.9
2.10
2.11
2.12
2.13
1250A, 1-phase 3pole, Short time current rating 31.5kA for 1sec, SF6
type with Spring operating mechanism, DC motor operated, suitable for
control voltage of 127VDC, control cabinet, piping, interpole cables,
cable glands, terminal blocks, marking ferrules, lugs, pressure gauge,
density monitor, support structure, minimum creepage distance
31mm/kV, complete as per specification.
3000A, 60 kV circuit breaker including frame (Coupling)
3000A, three pole, Short time current rating 31.5kA for 1sec, SF6 type
with Spring operating mechanism, DC motor operated, suitable for
control voltage of 127VDC, control cabinet, piping, interpole cables,
cable glands, terminal blocks, marking ferrules, lugs, pressure gauge,
density monitor, support structure, minimum creepage distance
31mm/kV, complete as per specification.
1600A, 220kV Three-pole Disconnectors Bars
1600A, Horizontal Double Break type, main switch shall be gang
operated, DC Motor operated, suitable for operating voltage of
127VDC, Short time current rating 31.5kA for 1sec, Solid core post
insulators, 8KN - 9Nos for each set, minimum creepage distance
31mm/kV and complete as per specification.
4000A, 220kV Three-pole Disconnectors Bars (Coupling)
4000A, Three pole horizontal double break type, main switch shall be
gang operated, DC Motor operated, suitable for operating voltage of
127VDC, Short time current rating 31.5kA for 1sec, Solid core post
insulators, 8KN - 9Nos for each set, minimum creepage distance
31mm/kV and complete as per specification.
1600A, 60kV Three-pole Disconnectors Bars
1600A, Horizontal Double Break type, main switch shall be gang
operated, DC Motor operated, suitable for operating voltage of
127VDC, Short time current rating 31.5kA for 1sec, Solid core post
insulators, 4.5kN - 9Nos for each set, minimum creepage distance
31mm/kV and complete as per specification.
1250A, 60kV Three-pole Disconnectors Bars
1250A, Horizontal Double Break type, main switch shall be gang
operated, DC Motor operated, suitable for operating voltage of
127VDC, Short time current rating 31.5kA for 1sec, Solid core post
insulators, 4.5kN - 9Nos for each set, minimum creepage distance
31mm/kV and complete as per specification.
3000A, 60kV Coupling Three-pole Disconnectors Bars
3000A, Three pole horizontal double break type, main switch shall be
gang operated, DC Motor operated, suitable for operating voltage of
127VDC, Short time current rating 31.5kA for 1sec, Solid core post
insulators, 4.5kN - 9Nos for each set, minimum creepage distance
31mm/kV and complete as per specification.
220kV Three-pole Line Disconnectors + Earthing switch
1600A, Three pole horizontal double break type, main & earth switch
shall be gang operated, DC Motor operated, suitable for operating
voltage of 127VDC, Short time current rating 31.5kA for 1sec, Solid
core post insulators, 8KN - 9Nos for each set, minimum creepage
distance 31mm/kV and complete as per specification.
Page 2 of 8
Remarks
Sl. No.
DESCRIPTION
Unit
Qty
2.14
Sets
09
2.15
Sets
03
Nos
03
Nos
03
Nos
09
Nos
09
Nos
03
Nos
09
Nos
02
2.16
2.17
2.18
1600A, Horizontal Double Break type, main & earth switch shall be
gang operated, DC Motor operated, suitable for operating voltage of
127VDC, Short time current rating 31.5kA for 1sec, Solid core post
insulators, 4.5kN - 9Nos for each set, minimum creepage distance
31mm/kV and complete as per specification.
1250A, 220kV Neutral Disconnectors
1250A, Three pole horizontal double break type, main switch shall be
gang operated, DC Motor operated, suitable for operating voltage of
127VDC, Short time current rating 31.5kA for 1sec, Solid core post
insulators, 8KN - 3Nos for each, minimum creepage distance 31mm/kV
and complete as per specification.
1250A, 60kV Neutral Disconnectors
1250A, Three pole horizontal double break type, main switch shall be
gang operated, DC Motor operated, suitable for operating voltage of
127VDC, Short time current rating 31.5kA for 1sec, Solid core post
insulators, 4.5kN - 3Nos for each, minimum creepage distance
31mm/kV and complete as per specification.
220kV Current transformer, 600-1200/ 1-1-1 A (Line )
Outdoor, 1-phase, oil filled, Short time current rating 31.5kA for 1sec,
Core1 : 600-1200/1A, for metering, 30VA, class: 0.5
Core2 : 600-1200/1A, for Line protection, 30VA, 5P20
Core3 : 600-1200/1A, for Line protection, 30VA, 5P20
Minimum creepage distance 31mm/kV and complete as per
specification.
2.19
2.20
2.21
2.22
Remarks
Sl. No.
2.23
DESCRIPTION
60kV Current transformer, 600-300 / 1-1A
Unit
Qty
Nos
27
Nos
09
Nos
27
Nos
09
Nos
02
Nos
09
Nos
09
Nos
09
LOT
Nos
1
07
Sets
02
LOT
LOT
LOT
Outdoor, 1-phase, oil filled, Short time current rating 31.5kA for 1sec,
Core1 : 600-300/1A, for metering, 30VA, class: 0.5
Core2 : 600-300/1A, for Line protection, 30VA, 5P20
Minimum creepage distance 31mm/kV and complete as per
specification.
2.24
2.25
2.26
2.27
2.28
2.29
2.30
2.31
2.32
2.33
2.34
2.35
2.36
Remarks
Sl. No.
DESCRIPTION
Unit
Qty
2.37
LOT
2.38
AGS tube
LOT
LOT
LOT
Nos
Nos
03
03
Nos
Nos
Nos
03
03
02
Nos
LOT
01
1
Nos
03
Nos
Nos
09
07
No
01
LOT
LOT
LOT
LOT
No
01
2.39
2.40
3
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
3.11
3.12
Page 5 of 8
Remarks
MAT is not
known
AGS not
known
Sl. No.
DESCRIPTION
4
4.1
AUXILLIARY SERVICES
500kVA TSA (Auxiliary Service Transformer) minimum
Outdoor, Three phase, 50Hz, 10/0.38kV Auxiliary Service Transformer,
ONAN type of cooling, vector group YnZn11,with insulating oil, with
cable box on secondary side, HV side terminal connectors suitable for
Almelec conductor - 3Nos. for each, and LV side cable box suitable for
7Nos 1C X 630sqmm XLPE armoured Al cable and with cable glands
and lugs, minimum creepage distance 31mm/KV and complete as per
specification.
Emergency unit (100kVA minimum ) + including start-up battery + Fuel
tank
Net electrical output 100kVA, 1500RPM, 380-220V, 3phase, 50Hz, DG
set shall be equipped with following:
(i) Diesel engine complete with all accessories.
(ii) An alternator directly coupled to the engine through coupling,
complete with all accessories.
(iii) Automatic voltage regulator.
(iv) Complete starting arrangement, including two nos. 24V batteries &
chargers.
(v) Base frame, foundation bolts etc.
(vi) Day tank of 990 Litre capacity.
(vii) Engine Cooling and lubrication system.
(viii) Engine air filtering system.
(ix) Exhaust silencer package.
(x) Set of GI pipes, valves, strainers, unloading hose pipes as required
for fuel transfer system from storage area to fuel tank including
electrically driven fuel pump.
(xi) All lubricants, consumable, touch up paints etc. for first filing,
testing & commissioning at site. The fuel oil for first commissioning.
(xii) AMF panel for control, metering and alarm along with transducers.
(xiii) Enclosure for silent type D.G. Set and complete as per
specification
4.2
Unit
Qty
Nos
02
LOT
4.3
4.4
LOT
Nos
1
02
4.5
Nos
01
Nos
03
4.7
Nos
02
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
LOT
LOT
LOT
LOT
LOT
LOT
LOT
LOT
1
1
1
1
1
1
1
1
4.16
LOT
4.17
LOT
4.6
Page 6 of 8
Remarks
Sl. No.
5
5.1
5.2
5.3
5.3.1
5.3.2
DESCRIPTION
HF, TELEPHONE AND TELEINFORMATION EQUIPMENT
Bi-channel BLU equipment
HF Digital automatic exchange equipment
SDH Equipment - STM16:
Side Post :
SDH Multiplexer - STM16 (Including amplifiers), interfaces, inputs and
outputs :
10 STM-4 interfaces
02 STM-4 interfaces
02 STM-1 interfaces
32 E1 interfaces
16 FE interfaces
PCM equipment: The supplier must provide for each station, PCM
equipment that can be connected to the SDH equipment and can be
recognized by the same management station's SDH equipment
10 E1 interfaces
20 RS 232 interfaces
8 RS 485 interfaces
20 interfaces 2 wire / 4 wire E&M
4 interfaces for remote subscriber connections
4 interfaces for hotline connections
Towards station side :
Extension SDH equipment for existing stations towards including
parameters, integration testing, commissioning and communications
5.4
5.5
5.6
5.7
6
6.1
6.2
6.3
6.4
6.5
7
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
1
2
Unit
Qty
Nos
No
22
1
Lot
Lot
Lot
Nos
Nos
18
22
Lot
Nos
1
3
No
LOT
LOT
1
1
LOT
LOT
LOT
1
1
LOT
LOT
LOT
LOT
LOT
LOT
LOT
1
1
1
1
1
1
1
LOT
Remarks
Sl. No.
3
4
5
6
7
8
9
DESCRIPTION
Unit
Qty
Page 8 of 8