Вы находитесь на странице: 1из 7

WWW.HYC-SYSTEM.

COM

HYC SYSTEM OPTOELECTRONICS TECHNOLOGY CO., LTD

HYC Fiber Patch Cord General Specification

General Information of Fiber Patch Cord:


Fiber Patch Cord consist of Ferrule, Connector parts and Cable, herewith
mainly including the technical specification for each components:

1.

Ferrule Generic Specification

This is a generic specification for ferrules optical features .


1.1.

Single Mode PC

its preferable to use 125.2-126.5 um ferrule.


The interferometric parameters to meet in case of finished connectorizations are:
Curvature (mm)

[ 7-25 ]

Offset Linear(um) < 50


Fiber Undercut(um) [ +/-100 ]
1.2.

Single Mode APC

its preferable to use 125.2-126.5 um ferrule of type conical

The interferometric parameters to meet in case of finished connectorizations are:

Curvature (mm)

[ 5-15 ]

Offset Linear(um) < 50


Fiber Undercut(um) [ +/-100 ]
APC angle (degrees) [ 8.0+/-0.5]
1.3.

Multi Mode Mode PC

its preferable to use 126-130um ferrule of

The interferometric parameters to meet in case of finished connectorizations are:

Curvature (mm)

type

[ 7-25 ]

Offset Linear(um) < 50


Fiber Undercut(um) [ +50 -100 ]

HYC System Optoelectronics Technology Co., Ltd.

HYC Fiber Patch Cord General Specification

2.

Connectors

2.1.

Connector generic optical specification table

This is a generic specification of connector optical specification required


Item

SINGLEMODE

MULTIMODE
FC, SC, ST,

FC, SC, ST, MU,

MT-RJ,

Terminations

MT-RJ, FDDI,
MU, LC, SMA,

LC, D4, DIN,

MPO

MPO, ESCON
DIN,D4

0.30 (PC)
Insertion Loss
0.30 (UPC)

0.3 (PC)

0.3 (PC)

35 (PC)

(dB)
0.2APC)
45 (PC)
Return Loss (dB)

50 (UPC)
60 (APC)

Temp Range

-40C to +80C

Insertion Loss measured as specified at IEC 61300-3-4


Return Loss measured as specified at IEC 61300-3-6
2.2. Connector Standards Compliance
SPECIFICATION TABLE
2.2.1. Generic Standards
All connector with RoHS compliance

HYC System Optoelectronics Technology Co., Ltd.

HYC Fiber Patch Cord General Specification


2.2.2.

Particular Standards

Particular Standard
Type of Connector
to meet with
SC

ISO/IEC 11801, TIA 568 A

FC

JIS 5970, EIA/TIA FOCIS

ST

BellCore GR-326, TIA 568 A

LC

ISO/IEC 11801, TIA 568 A


IEC 60874 -1
CECC 86 305 801 (MU-APC)

MU
I-ETS 300 671
IEC 61300
ANSI/TIA/EIA-568-B
MTRJ

ISO/IEC 11801
EN 50173

DIN

DIN 47256

D4

3.

MPO

IEC61754-7, TIA/EIA 604-5

ESCON

IBM SA22-7202-00

FDDI

ANSI X379.5

Generic Cable Specification


HYC System Optoelectronics Technology Co., Ltd.

HYC Fiber Patch Cord General Specification


3.1. Single Mode Cables,
This cables must always be of kind 9/125 um, UIT-T G.652D and must be compatible with
G657A (unless other thing explained), and Low Smoke Zero Halogen.
/

OS1

(1310nm/1550nm)

Attenuation(db/km)

0.4/0.3

Table 1. Single Mode Attenuation


3.2. MultiMode Cables
This cables could be be of kind 50/125 um or 62.5/125um ,

compilants with the

standards related in table above depending of kind of fibre selected (unless other thing
explained), and Low Smoke Zero Halogen.
By the default, a request of 50/125 um cable will be specifying a OM2 cable. If a OM3 cable is
required it must be specified on request
Meassures: 62.5/125 m
OM1
Standards: IEC 60793-2-10 Type A1b.1; ISO/IEC 11801 OM1
Meassures: 50/125 m
OM2
Standards: IEC 60793-2-10 Type A1a.1; ISO/IEC 11801 OM2
Meassures: 50/125 m
OM3
Standards: IEC 60793-2-10 Type A1a.2, ISO/IEC 11801 OM3
Table 1. Multimode type of fibers
OM1

OM2

OM3

(850nm/1300nm)

(850nm/1300nm)

(850/1300nm)

3.0/0.8

2.6/0.7

2.6/0.7

Attenuation(db/km)
Table 2. Multimode Attention

HYC System Optoelectronics Technology Co., Ltd.