Вы находитесь на странице: 1из 12

Possible TELOC error messages

Each error message receives a unique code, (this code is associated with a unique software ERRC_ name)
The error messages are classified. For each code range an error definition is given (see next pages from this document).

Types

II
IE
WI
WE
FI
FE

Levels

Codes

Info Internal

500-599

Info External

600-699

Warning Internal

Warning External

100-199
200-299
400-499

Fatal Internal

000-099

Fatal External

300-399

TELOC
Healthy

ERROR

TELOC Healty indicates an internal or external


event and is adjustable to have more or less
Levels. (E.g. can also get activated if only Level 8
and / or 9, that means an Fatal ERROR, has
occured. An other possible option would be to set it
if and Fatal Error and / or Warning has occured).

An error is fatal if the recording of the data is not possible by the Teloc. If the speed is not recorded, a fatal error is reported.
A warning indicates that the Teloc is not recording properly (the recording is disturbed somehow).
In that case it is possible that some data are not recorded because a communication is not working for example, but at least the speed is recorded.
An Info indicates that the Teloc is not working properly somehow. Exploitation errors may also be classified here (for example a not allowed input state).
In that case the recording is not disturbed at all!
Events are used to save important events generated by the Teloc.
Events may be used to delete one or several info/warning/errors: for example, the Cassette Out warning is deleted by the Cassette In event.
Internal errors are generated by the TELOC and the solution has to do with the TELOC itself.
The possible solutions of the problem are: Hardware update, Software update or a configuration change.
External errors are generated by an external communication, which is not working properly.
In that case the TELOC is working perfectly and the solution of the problem is external to the device.

HaslerRail AG - Confidential
ErrorList.xls

01.12.2011

Teloc 2500 - Error list

000 - 099 Strong system errors


The errors in this list are program bugs or configuration errors. To solve the problem, a software fix, hardware fix or a new configuration is necessary.
The recording cannot take place! The Teloc is not working at all!
A Software reset is automatically generated for error code between 050 and 099.
Error Code Error Level
000
FI
006
FI
020
FI
021
FI
022
FI
023
FI
024
FI
030
FI
049
FI
060
Fl
061
Fl
062
Fl
099
FI

HaslerRail AG - Confidential
ErrorList.xls

SW Name
ERRC_NO_ERRORCODE

Codes to delete
-

ERRC_WRONG_SW_CRC
ERRC_WRONG_CONFIG_VERSION
ERRC_UNCONFIGURED
ERRC_CONF_ERROR
ERRC_SABO_CONF_ERROR
ERRC_WRONG_CONFIG_CRC
ERRC_USER_ALARM_FI
ERRC_INIT_ERROR
ERRC_SABO_FATAL_CH1
ERRC_SABO_FATAL_CH2
ERRC_SABO_FATAL
ERRC_INTERNAL_FATAL_ERROR

Error message (32 char max)


Software is corrupted
Wrong configuration version
Teloc is not configured
Configuration error
Sabo configuration error
Configuration is corrupted
User alarm level 8
Initialisation error
SABO fatal error CH1
SABO fatal error CH2
SABO fatal
Internal Fatal error

Error/Event explanation
No error
The SW CRC is wrong
The configuration doesn't correspond to the actual program.
No configuration downloaded. Default configuration used.
The configuration has an error.
Sabo configuration has an error
The configuration is corrupted.
User alarm level 8 configurable
A general fatal error that happened during the initialisation phase
The chanel 1 of the SABO board has a fatal error
The chanel 2 of the SABO board has a fatal error
The SABO board has a fatal error encountered
Div/0 or NULL pointer,

01.12.2011

Teloc 2500 - Error list

100 - 199 Internal system warnings


A warning inside of the Teloc disturbs the recording. The solution of the problem is a parameter to be entered with the service program.
The recording still takes place but some data might be wrong or not recorded. Vehicle speed is OK.
Teloc functionnalities are working properly (if no other Teloc problem reported).
Error Code Error Level
110
WI
120
WI
121
WI
130
WI
140
WI
141
WI
150
WI
160
WI
161
WI
162
WI
163
WI
164
WI
165
WI
166
WI
167
WI
168
WI
169
WI

HaslerRail AG - Confidential
ErrorList.xls

SW Name

Codes to delete
ERRC_NO_VEHICLE_ID
912
ERRC_WRONG_VEHICLE_ID
ERRC_WHEELDIAM_BAD
ERRC_RECORDING_FAILED
ERRC_RECORDING_STOPPED
706
ERRC_LOST_BACKUP_DATA
ERRC_USER_ALARM_WI
ERRC_POS12V_FAILURE
986
ERRC_NEG12V_FAILURE
ERRC_CFTP_CESSION_OPEN
723
ERRC_CROC_RELAIS_CHECk
764
ERRC_CROC_BRAKERELAIS_FEEDBACK
765
ERRC_CROC_BRUSH_ERROR
766
ERRC_DIG_INPUT
769
ERRC_DATR_WARNING
168
ERRC_DATR_COM_ERROR
ERRC_DEFAULT_TIME_SET

Error message (32 char max)


Error/Event explanation
Enter new date/time. Default:Default time/date loaded. Time/date to be changed.
No vehicule ID. Default:
No vehicule Id specified yet. Vehicle Id to be changed with SG.
Wrong vehicule ID
The actual vehicule Id is not valid. Vehicle Id to be changed with SG.
Bad wheel diam. :
The wheel diameter is not defined or not in range. Wheel diameter to be changed.
Recording failed
The recording has failed
Recording stopped
The recording is stopped due to a download, an upload , an erase
Wrong data from backup RAM
The RTC Ram contains wrong Data due to a bad battery or first start ot Teloc2500
User alarm level 4
User alarm level 4 configurable
Positive 12V failure
The +12V is out of range
Negative 12V failure
The -12V is out of range
CFTP data upload started
ATPRD project: A data upload cession is required through MBV II/CFTP
relais check failed
CROCA: The check of relais failed
brakerelais feedback failed CROCA: The check of brakerelais feedback failed
brush error
CROCA: Brush Error
Digital Input Error:
Hardware problem around the digital inputs
DATR board warning:
The DATR board has notify a problem
DATR communication error
Communication problem with DATR board

01.12.2011

Teloc 2500 - Error list

200 - 299 Memory warnings


The errors in this list are warnings that have to do with the memory.
The recording cannot take place normally in every memory type.
The Teloc recording capability is disturbed somehow.
Error Code
255
260

Error Level
WE

ERRC_FPM_NOT_CONNECTED

913

Crash Protected Memory

261
262
263
264
265
266
267
268
269
270
271
272
273
274
275

WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE

ERRC_FPM_LOCKED

913
913
915
922
923
924
925
926
927
928
929
-

Crash Protected Memory


Crash protected Memory
STM has been locked
LTM has been locked
EVM has been locked
CPM ERROR
FLEXM1 has been locked
FLEXM2 has been locked
FLEXM3 has been locked
FLEXM4 has been locked
FLEXM5 has been locked
FLEXM6 has been locked
FLEXM7 has been locked
FLEXM8 has been locked
DATR memory problem

HaslerRail AG - Confidential
ErrorList.xls

SW Name

EERC_FPM_ERROR_OR_BUSY
ERRC_STM_LOCKED
ERRC_LTM_LOCKED
ERRC_EVM_LOCKED
ERRC_FPM_ERROR
ERRC_FXM1_LOCKED
ERRC_FXM2_LOCKED
ERRC_FXM3_LOCKED
ERRC_FXM4_LOCKED
ERRC_FXM5_LOCKED
ERRC_FXM6_LOCKED
ERRC_FXM7_LOCKED
ERRC_FXM8_LOCKED
ERRC_DATR_MEM_WARN

Codes to delete

Error message (32 char max)

Error/Event explanation
This error code cannot be used because it could give failure on CPM software version older than S02.22
not connectedNo contact with Crash protected Memory (CPM)
The CPM is not connected to his assigned TELOC.
To reset the assignement, you must erase all CPM data
locked
error or busyinternal error or the CPM is busy
STM has been locked. You must read the whole content of the internal STM.
LTM has been locked. You must read the whole content of the internal LTM.
EVM has been locked. You must read the whole content of the internal EVM.
Internal error in CPM or message queue for CPM full
FLEXM1 has been locked. You must read the whole content of the internal FLEXM1.
FLEXM2 has been locked. You must read the whole content of the internal FLEXM2.
FLEXM3 has been locked. You must read the whole content of the internal FLEXM3.
FLEXM4 has been locked. You must read the whole content of the internal FLEXM4.
FLEXM5 has been locked. You must read the whole content of the internal FLEXM5.
FLEXM6 has been locked. You must read the whole content of the internal FLEXM6.
FLEXM7 has been locked. You must read the whole content of the internal FLEXM7.
FLEXM8 has been locked. You must read the whole content of the internal FLEXM8.
A problem occurred around the DATR memories

01.12.2011

Teloc 2500 - Error list

300 - 399 External fatal error


An error outside of the Teloc makes the recording impossible. The solution of the problem is outside of the Teloc.
The recording cannot take place!
No Teloc recording until external problem solved. The Teloc is waiting for valid Data.
Error Code Error Level
301
FE
312
FE
313
FE
314
FE
315
FE
316
FE
317
FE
318
FE
319
FE
320
FE
321
FE
322
FE

HaslerRail AG - Confidential
ErrorList.xls

SW Name
ERRC_NO_VALID_SPEED
ERRC_INVALID_DAIO_NB
ERRC_INVALID_REBO_NB
ERRC_INVALID_BOAB_NB
ERRC_INVALID_MAINB_NB
ERRC_INVALID_GPSM_NB
ERRC_INVALID_GIOC_NB
ERRC_VPC_BOARD

Codes to delete
-

ERRC_INVALID_SABO_NB
ERRC_USER_ALARM_FE
ERRC_INVALID_CROC_NB
ERRC_INVALID_DATR_NB

Error message (32 char max)


No speed valid.
Bad source/target ID
Bad target ID
Bad source/target ID
Bad source/target ID
Bad source/target ID
Invalid GIOC slot ID
Problem with VPC board
Invalid SABO connector coding
User alarm level 9
Bad source/target ID
Invalid DATR connector coding

Error/Event explanation
No speed valid. No speed recorded.
Invalid connector ID or missing card. Recording of signals is invalid
Invalid connector ID or missing card. Recording of signals is invalid
Invalid connector ID or missing card. Recording of signals is invalid
Invalid connector ID or missing card. Recording of signals is invalid
Invalid connector ID or missing card. Recording of signals is invalid
Invalid connector ID or missing card. Recording of signals is invalid
The VPC board needs to be new configured
Invalid connector ID or missing card. Recording of signals is invalid
User alarm level 9 configurable
Invalid connector ID or missing card. Recording of signals is invalid
Invalid connector ID or missing card. Recording of signals is invalid

01.12.2011

Teloc 2500 - Error list


400 - 499 External warnings
A warning outside of the Teloc disturbs the recording. The solution of the problem is outside of the Teloc.
The recording still takes place but some data might be wrong or not recorded. Vehicle speed is OK.
Teloc functionnalities are working properly (if no other Teloc problem reported).
Error Code Error Level
401
WE
402
WE
403
WE
404
WE
405
WE
406
WE
407
WE
408
WE
409
WE
410
WE
411
WE
412
WE
413
WE
414
WE
415
WE
416
WE
417
WE
418
WE
419
WE
420
WE
421
WE
422
WE
423
WE
424
WE
425
WE
426
WE
427
WE
428
WE
429
WE
430
WE
431
WE
432
WE
433
WE
434
WE
435
WE
436
WE
437
WE
438
WE
439
WE
440
WE
441
WE
442
WE
443
WE
444
WE
445
WE
446
WE
447
WE
448
WE
449
WE
450
WE
451
WE
452
WE
453
WE
454
WE
455
WE
HaslerRail AG - Confidential
ErrorList.xls

SW Name
Codes to delete
ERRC_SPEED_INPUT1_FAILED
ERRC_SPEED_INPUT2_FAILED
ERRC_SPEED_INPUT3_FAILED
ERRC_SPEED_INPUT4_FAILED
ERRC_DIRECTION_FAILED
708
ERRC_SABO_TEST_FAILURE
ERRC_SABO_SPEED_INPUT1_FAILED
ERRC_SABO_SPEED_INPUT2_FAILED
ERRC_SABO_DIRECTION_FAILED
ERRC_USER_ALARM_WE
ERRC_JRU_COMM_FAILURE
707
ERRC_PPIB_COMM_FAILURE
ERRC_PPIB_CONFIGURATION_FAILURE
ERRC_VOICE_COMM_FAILURE
ERRC_GPS_COMM_FAILURE
714
ERRC_HDLC_COMM_FAILURE
ERRC_MVBS_OLD_DATA
718
ERRC_MVBS_TIME_NO_SYNCH
719
ERRC_JRU_COMM_FAILURE - B
720
ERRC_VOICE_COMM_FAILURE - A
721
ERRC_VOICE_COMM_FAILURE - B
722
ERRC_MVB_FRESHNESS_FAILED
724
ERRC_OTEK_DISP_COMM_FAIL
725
ERRC_CAN104_FATAL
728
ERRC_M2HPTS_FAILURE
709
ERRC_BARE_COMM_FAILURE
763
ERRC_CROC_EXT_BATTERY
768
ERRC_DATABIN_TMS_FAILURE
771
ERRC_DATABIN_T2200_FAILURE
772
ERRC_SABO_WARNING_03_CH1
731
ERRC_SABO_WARNING_03_CH2
732
ERRC_SABO_WARNING_04_CH1
733
ERRC_SABO_WARNING_04_CH2
734
ERRC_SABO_WARNING_05_CH1
735
ERRC_SABO_WARNING_05_CH2
736
ERRC_SABO_WARNING_06_CH1
737
ERRC_SABO_WARNING_06_CH2
738
ERRC_SABO_WARNING_07_CH1
739
ERRC_SABO_WARNING_07_CH2
740
ERRC_SABO_WARNING_08_CH1
741
ERRC_SABO_WARNING_08_CH2
742
ERRC_SABO_WARNING_09_CH1
743
ERRC_SABO_WARNING_09_CH2
744
ERRC_SABO_WARNING_10_CH1
745
ERRC_SABO_WARNING_10_CH2
746
ERRC_SABO_WARNING_23_CH1
747
ERRC_SABO_WARNING_23_CH2
748
ERRC_SABO_WARNING_24_CH1
749
ERRC_SABO_WARNING_24_CH2
750
ERRC_SABO_WARNING_25_CH1
751
ERRC_SABO_WARNING_25_CH2
752
ERRC_SABO_WARNING_26_CH1
753
ERRC_SABO_WARNING_26_CH2
754
ERRC_SABO_WARNING_28_CH1
755
ERRC_SABO_WARNING_28_CH2
756

Error message (32 char max)


Speed sensor 1 failure
Speed sensor 2 failure
Speed sensor 3 failure
Speed sensor 4 failure
Direction failure
Sabo test failed
Sabo speed sensor 1 failure
Sabo speed sensor 2 failure
Sabo direction failed
User alarm level 5
JRU communication failure
PPIB communication failure
PPIB configuration failure
VOICE communication failure
Gps cable not connected
No comm. on HDLC port
MVB Err port(s):
MVB Time not synch
ATPRD.Profibus.B.Error
VOICE communication failure
VOICE communication failure
MVB process data freshness fail
OTEK Display comm fail
Fatal Error on CAN104 board
M2HPTS error
Badge Reader communication failure
External Battery Error
Databin TMS comm failed
Databin T2200 comm failed
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:

Error/Event explanation
The speed given by the sensor 1 is wrong.
The speed given by the sensor 2 is wrong.
The speed given by the sensor 3 is wrong.
The speed given by the sensor 4 is wrong.
different direction detected
The speed given by the sensor 3 is wrong.
The speed given by the sensor 1 is wrong.
The speed given by the sensor 2 is wrong.
User alarm level 5 configurable
No sign of life of the JRU device (no data received)
No sign of life of the PPIB board (no data received)
Bad configuration on ppib
Error in communication with VOICE card
No possiblity to communicate with gps
There is no communication on the HDLC port
MVB ports not fresh when read
Time difference between RTC and MVB time > time diff in @915
No sign of life of the JRU device (no data received)
Error in communication with VOICE card
Error in communication with VOICE card
Error in communication with MVB card
Error in communication with OTEK Display
The CAN104 board is not correctly configured
M2 HPTS protocoll error
The Badge reader communication is not running or disturbed
The CROC board has announced a ext. Battery error
Communication on the Databin TMS interface failed
Communication on the Databin T2200 interface failed
Missing Frequency other FPGA
Missing Frequency other FPGA
Speed difference detected
Speed difference detected
Emergency test failed
Emergency test failed
Emergency test FPGA2 failed
Emergency test FPGA2 failed
Missing frequency input 1
Missing frequency input 1
Missing frequency input 2
Missing frequency input 2
Different Detected direction
Different Detected direction
SABO compare results failed
SABO compare results failed
Temperature level 1 reached
Temperature level 1 reached
Temperature level 2 reached
Temperature level 2 reached
Missing Hardware-ID
Missing Hardware-ID
Missing Hardware-ID FPGA 2
Missing Hardware-ID FPGA 2
Zero speed feedback failed
Zero speed feedback failed

01.12.2011

Teloc 2500 - Error list


456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489

WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE
WE

HaslerRail AG - Confidential
ErrorList.xls

ERRC_SABO_WARNING_29_CH1
ERRC_SABO_WARNING_29_CH2
ERRC_SABO_WARNING_30_CH1
ERRC_SABO_WARNING_30_CH2
ERRC_SABO_WARNING_31_CH1
ERRC_SABO_WARNING_31_CH2
ERRC_SABO_WARNING
ERRC_VOBC_COMM_TIMEOUT
ERRC_OTEK_DISP_COMM2_FAIL
ERRC_VOBC_BAD_FRAME
ERRC_VOBC_BAD_NUMBER
ERRC_IBIS_COMM_TIMEOUT
ERRC_IBIS_BAD_FRAME
ERRC_ATC_COMM_TIMEOUT
ERRC_DSAT_COMM_TIMEOUT_A
ERRC_DSAT_COMM_TIMEOUT_B
ERRC_SPEEDO_COMM_1_ERR
ERRC_SPEEDO_COMM_2_ERR
ERRC_SSL_TCMS_TIME_NO_SYNCH
ERRC_ETCS_SYSTEM_INIT
ERRC_TCMS_COMM_TIMEOUT
ERRC_TCMS_BAD_FRAME
ERRC_LTZH_COMM_0_TIMEOUT
ERRC_LTZH_COMM_1_TIMEOUT
ERRC_LTZH_BAD_FRAME
ERRC_RCESSC_TIMEOUT
ERRC_CRT_TIMEOUT
ERRC_LOGYTEL_COMM_1_ERR
ERRC_LOGYTEL_COMM_2_ERR
ERRC_ASFA_COMM_TIMEOUT
ERRC_TELOC2TELOC_TIMEOUT
ERRC_QEVR_ERR
ERRC_BEIJING_ATP_ERR
ERRC_DUALMVB_ERR

757
758
759
760
761
762

SABO warning CH1:


SABO warning CH2:
SABO warning CH1:
SABO warning CH2:
SABO warning CH1:
SABO warning CH2:

RAM access time out


RAM access time out
Power error (Mutant) (after init frq. In phs.)
Power error (Mutant) (after init frq. In phs.)
Different DIGIN Values detected
Different DIGIN Values detected

770
792
774
775
776
777
778
779
780
783
800
783
784
785
786
787
788
790
791
793
794
795
796
797
798
799

VOBC comm timeOut


OTEK Display comm fail
VOBC bad frame
VOBC bad frame number
IBIS comm timeOut
IBIS bad frame
serial comm timeOut

No char received from VOBC for 10 seconds

Speedo comm 1 timeOut


Speedo comm 2 timeOut
SSL TCMS time not synch
Profibus/FFFIS stack did not start
TCMS comm timeOut
TCMS bad frame
no valid frame [s]: x
no valid frame [s]: x
LTZH bad frame
CASRAM-RCE-SSC Protocol
CASRAM CRT protocol
Logytel Display 1 comm error
Logytel Display 2 comm error
ASFA Digital communication timeout
Yellow Machines TELOC to TELOC serial protocol
QEVR
BEIJING_ATP
DualMVB

No char received from Speedo for x seconds


No char received from Speedo for x seconds
Time difference between RTC and TCMS time > time diff in @942

VOBC sent an invalid frame (bad length, wrong CRC)


VOBC send a bad frame number (counter is wrong)
No char received on IBIS for 10 seconds
Invalid frame received on IBIS (bad length, wrong parity)
No char or invalid frame received on serial Interface

No char received from TCMS (ELL, Gautrain) for x seconds


Invalid frame (bad length, wrong parity) received from TCMS (ELL, Gautrain)
No valid frame received within the last x seconds. x is "Communication TimeOut" in KW945
No valid frame received within the last x seconds. x is "Communication TimeOut" in KW945
Invalid frame received from LTZH (bad length, wrong parity)
Communication timeout
Communication timeout
Communication problem with Logytel display #1
Communication problem with Logytel display #2
Communication problem with ASFA Digital (Renfe)
Communication timeout
Communication timeout or frame error or CRC error
Communication timeout or frame error or CRC error
Communication problem on dual-MVB interface

01.12.2011

Teloc 2500 - Error list

500 - 599 Internal Info


An internal problem is reported by the Teloc. The solution of the problem is inside of the Teloc. Configuration is OK.
The recording is not disturbed and still takes place normally.
Teloc functionnalities are working properly (if no other Teloc problem reported).
Error Code Error Level
501
II
503
II
510
II
511
519
II
520
II
521
II
522
II
530
II
531
II

HaslerRail AG - Confidential
ErrorList.xls

SW Name
ERRC_VME_BUS_DISTURBED
ERRC_ALIGNMENT_REPORT
ERRC_USER_ALARM_II
ERRC_DATE_BATTERY
ERRC_CHANGE_BATTERY
ERRC_GPS_TIME_LOST
ERRC_GPS_POSI_LOST
ERRC_GSM_ERROR
ERRC_DATR_INFO

Codes to delete
Error message (32 char max)
VME Bus disturbed
Bad alignment gave reboot
User alarm level 2
710
715
716
531

Battery is too old


Battery failure
No time from gps
No position for gps
GSM error
DATR board info:

Error/Event explanation
The VME Bus has been disturbed before the last reboot
A faulty alignment occurred and has given a reboot
User alarm level 2 configurable
This error code cannot be used because it could give failure on CPM software version older than S02.22
Battery is older than x years. Must be replaced.
RTC battery failure please change battery
Gps connected but rtc not initialized
Not enough satellites for position fixes
error with GSM handling
The DATR board has notify an information

01.12.2011

Teloc 2500 - Error list

600 - 699 External Info


An external problem is reported by the Teloc. The solution of the problem is outside of the Teloc.
The recording is not disturbed and still takes place normally.
Teloc functionnalities are working properly (if no other Teloc problem reported).
Error Code Error Level

SW Name

601

EI

ERRC_COM_SDDISPLAY

602
610
620
621

EI
EI
EI
EI

ERRC_EEPROM

HaslerRail AG - Confidential
ErrorList.xls

ERRC_USER_ALARM_IE
ERRC_USB_STICK_IN
ERRC_SABO_CONFIG

Codes to delete
727

Error message (32 char max)


SDdisplay communication error
Problem with external eeprom
User alarm level 3
USB stick plugged
Sabo in config mode

Error/Event explanation
this error occure when the Sddisplay doesn't answer or
answers false at least 5 times
An error occurs due the external eeprom (Not present,
cannot read, cannot write, ...)
User alarm level 3 configurable
A stick is plugged
Sabo is in config mode

01.12.2011

Teloc 2500 - Error list

700 - 899 Events for external warning deletion


These events are used to remove external warnings/info from the error list. No error entry is added to the actual error list.
The recording takes place normally.

Error Code
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753

Error Level
-

SW Name
ERRC_SPEED_INPUT1_OK
ERRC_SPEED_INPUT2_OK
ERRC_SPEED_INPUT3_OK
ERRC_SPEED_INPUT4_OK
ERRC_COM_SDDISPLAY_OK
ERRC_RECORDING_RESTARTED
ERRC_JRU_COMM_OK
ERRC_DIRECTION_OK
ERRC_M2HPTS_OK
ERRC_DATE_BATTERY_OK
ERRC_PPIB_COMM_OK
ERRC_PPIB_CONFIGURATION_OK

ERRC_VOICE_COMM_OK
ERRC_GPS_COMM_OK
ERRC_GPS_TIME_OK
ERRC_GPS_POSI_OK
ERRC_USB_STICK_OUT

ERRC_HDLC_COMM_OK
ERRC_VPC_BOARD_OK
ERRC_MVBS_DATA_OK
ERRC_MVBS_TIME_SYNCH_OK

ERRC_JRU_COMM_OK - B
ERRC_VOICE_COMM_OK - A
ERRC_VOICE_COMM_OK - B
CFTP_CESSION_CLOSE
ERRC_MVB_FRESHNESS_OK
ERRC_OTEK_DISP_COMM_OK

HaslerRail AG - Confidential
ErrorList.xls

ERRC_GSM_INFO
ERRC_SABO_NOT_CONFIG
ERRC_CAN104_OK
ERRC_SABO_WARNING_03_CH1_OK
ERRC_SABO_WARNING_03_CH2_OK
ERRC_SABO_WARNING_04_CH1_OK
ERRC_SABO_WARNING_04_CH2_OK
ERRC_SABO_WARNING_05_CH1_OK
ERRC_SABO_WARNING_05_CH2_OK
ERRC_SABO_WARNING_06_CH1_OK
ERRC_SABO_WARNING_06_CH2_OK
ERRC_SABO_WARNING_07_CH1_OK
ERRC_SABO_WARNING_07_CH2_OK
ERRC_SABO_WARNING_08_CH1_OK
ERRC_SABO_WARNING_08_CH2_OK
ERRC_SABO_WARNING_09_CH1_OK
ERRC_SABO_WARNING_09_CH2_OK
ERRC_SABO_WARNING_10_CH1_OK
ERRC_SABO_WARNING_10_CH2_OK
ERRC_SABO_WARNING_23_CH1_OK
ERRC_SABO_WARNING_23_CH2_OK
ERRC_SABO_WARNING_24_CH1_OK
ERRC_SABO_WARNING_24_CH2_OK
ERRC_SABO_WARNING_25_CH1_OK
ERRC_SABO_WARNING_25_CH2_OK
ERRC_SABO_WARNING_26_CH1_OK

Codes to delete
401
402
403
404
601
141
411
405
425
519
412
413
414
415
521
522
620
416
318
417
418
419
420
421
163
422
423
530
621
321
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452

Error/Event explanation

Error message (32 char max)


Speed sensor 1 is OK
Speed sensor 2 is OK
Speed sensor 3 is OK
Speed sensor 4 is OK
Sddisplay communication ok
Recording restarted
JRU communication ok

Speed input 1 is OK.


Speed input 2 is OK.
Speed input 3 is OK.
Speed input 4 is OK.
Sddisplay answers again
The recording is restarted
JRU communication restarted

Sabo direction ok
M2HPTS information
New Battery date ok
PPIB communication ok
PPIB configuration ok
VOICE communication ok

Information about M2 HPTS protocoll


Date changed after new battery installation
PPIB communication restarted
PPIB reconfigured
VOICE communication restarted

gps OK
gps OK
gps OK
USB stick unplugged
Comm. on HDLC port OK
VPC board is working
MVB read port(s) OK
MVB Time synch
JRU communication ok
VOICE communication ok
VOICE communication ok
CFTP data upload stopped
MVB Freshness is ok
OTEK Display comm ok
GSM information
Sabo normal mode
CAN104 works
missing freq. CHx ch1 ok
missing freq. CHx ch2 ok
speed difference ch1 ok
speed difference ch2 ok
"Emergency tst fail ch1 ok
"Emergency tst fail ch2 ok
Emer. tst CHx fail ch1 ok
Emer. tst CHx fail ch2 ok
missing freq. in 1 ch1 ok
missing freq. in 1 ch2 ok
missing freq. in 2 ch1 ok
missing freq. in 2 ch2 ok
differ. direction ch1 ok
differ. direction ch2 ok
comp. result fail ch1 ok
comp. result fail ch2 ok
temp. 1 reached ch1 ok
temp. 1 reached ch2 ok
temp. 2 reached ch1 ok
temp. 2 reached ch2 ok
missing HW-ID ch1 ok
missing HW-ID ch2 ok
missing HW-ID CHx ch1 ok

Communication on the HDLC port restarted


The VPC board is working
MVB port(s) is(are) fresh when reading
Time difference between RTC and MVB time < time diff in @915
JRU communication restarted
VOICE communication restarted
VOICE communication restarted
ATPRD project: A data upload cession is stopped through MBV II/CFTP
The signal from process data is updated again
The communication with the OTEK display is OK
information about GSM
Sabo is okay
The CAN104 board is okay
Missing Frequency other FPGA ok
Missing Frequency other FPGA ok
Speed difference detected ok
Speed difference detected ok
Emergency test failed ok
Emergency test failed ok
Emergency test FPGA2 failed ok
Emergency test FPGA2 failed ok
Missing frequency input 1 ok
Missing frequency input 1 ok
Missing frequency input 2 ok
Missing frequency input 2 ok
Different Detected direction ok
Different Detected direction ok
SABO compare results failed ok
SABO compare results failed ok
Temperature level 1 reached ok
Temperature level 1 reached ok
Temperature level 2 reached ok
Temperature level 2 reached ok
Missing Hardware-ID ok
Missing Hardware-ID ok
Missing Hardware-ID FPGA 2 ok

01.12.2011

Teloc 2500 - Error list


754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804

HaslerRail AG - Confidential
ErrorList.xls

ERRC_SABO_WARNING_26_CH2_OK
ERRC_SABO_WARNING_28_CH1_OK
ERRC_SABO_WARNING_28_CH2_OK
ERRC_SABO_WARNING_29_CH1_OK
ERRC_SABO_WARNING_29_CH2_OK
ERRC_SABO_WARNING_30_CH1_OK
ERRC_SABO_WARNING_30_CH2_OK
ERRC_SABO_WARNING_31_CH1_OK
ERRC_SABO_WARNING_31_CH2_OK
ERRC_BARE_COMM_OK
ERRC_CROC_RELAIS_CHECK_OK
ERRC_CROC_BRAKERELAIS_FEEDBACK_OK

ERRC_CROC_BRUSH_ERROR_OK
ERRC_DIGINPUT_OK
ERRC_CROC_BATTERY_OK
ERRC_DIGINPUT_OK
ERRC_VOBC_COMM_OK
ERRC_TMS_COMM_OK
ERRC_T2200_COMM_OK
ERRC_VOBC_MSG1_OK
ERRC_VOBC_FRAME_OK
ERRC_VOBC_FRAME_NUMBER_OK
ERRC_IBIS_COMM_OK
ERRC_IBIS_FRAME_OK
ERRC_ATC_COMM_OK
ERRC_DSAT_COMM_A_OK
ERRC_DSAT_COMM_B_OK

ERRC_SSL_TCMS_COMM_OK
ERRC_SSL_TCMS_FRAME_OK

ERRC_SPEEDO_COMM_1_OK
ERRC_TCMS_COMM_OK
ERRC_TCMS_FRAME_OK
ERRC_LTZH_COMM_0_OK
ERRC_LTZH_COMM_1_OK
ERRC_LTZH_FRAME_OK
ERRC_DATR_COM_INFO
ERRC_RCESSC_OK
ERRC_CRT_OK

ERRC_OTEK_DISP_COMM2_OK
ERRC_LOGYTEL_COMM_1_OK
ERRC_LOGYTEL_COMM_2_OK
ERRC_ASFA_OK

ERRC_TELOC2TELOC_OK
ERRC_QEVR_OK
ERRC_BEIJING_ATP_OK
ERRC_DUALMVB_OK
ERRC_SPEEDO_COMM_2_OK

453
454
455
456
457
458
459
460
461
426
164
165
166
167
427
167
463
428
429
464
465
466
467
468
469
470
471
622
623
474
476
477
478
479
480
169
481
482
464
483
484
485
486
487
488
489
473

missing HW-ID CHx ch2 ok


zero speed feddback ch1 ok
zero speed feddback ch2 ok
RAM access timeout ch1 ok
RAM access timeout ch2 ok
power check fail ch1 ok
power check fail ch2 ok
d. input different ch1 ok
d. input different ch2 ok
BARE comm OK
relais check OK
brakerelais feedback OK
brush error end
Digital Input Error end:
Ext. Battery is OK
Digital Input Error end:
VOBC communication OK
Databin TMS comm OK
Databin T2200 comm OK
VOBC_Msg1_received
VOBC_Frame_OK
VOBC_Frame_Number_OK
IBIS communication OK
IBIS_Frame_OK
serial com OK
SSL-ATP communication A OK
SSL-ATP communication B OK

SSL TCMS comm OK


SSL TCMS frame OK
Speedo comm 1 OK
TCMS comm timeOut
TCMS bad frame
Valid frame received
Valid frame received
LTZH bad frame
DATR communication info
CASRAM-RCE-SSC Protocol
CASRAM CRT protocol

OTEK Display comm ok


Logytel display 1 comm ok
Logytel display 2 comm ok
ASFA digital communication

Yellow Machines TELOC to TELOC


Queensland Rail Event Recorder comm. OK
Beining ATP comm OK

Missing Hardware-ID FPGA 2 ok


Zero speed feedback failed ok
Zero speed feedback failed ok
RAM access time out ok
RAM access time out ok
Power error (Mutant) (after init frq. In phs.) ok
Power error (Mutant) (after init frq. In phs.) ok
Different DIGIN Values detected ok
Different DIGIN Values detected ok
Communication on the Bare port restarted or OK again
Error announced via VME on address 0x400[2]
Error announced via VME on address 0x400[5]
Error announced via VME on address 0x400[6]
used only on version S03.40C001and moved to code 769 after because it can give failure of the CPM
External Battery alarm is over and battery ok again
No more Digital Input error
Communication with VOBC OK. Char received.
Communication on the Databin TMS interface restarted or OK again
Communication on the Databin T2200 interface restarted and OK again
VOBC message type 1 received
VOBC frame is valid (CRC and length)
VOBC frame number is correctly incremented
Communication on IBIS OK. Char received.
IBIS frame is valid (Parity and length)
Communication on serial Interface OK. New valid frame received.
Communication on SSL-ATP chanel A is okay.
Communication on SSL-ATP chanel B is okay.
Communication with SSL TCMS OK. Char received.
SSL TCMS frame is valid (CRCs and length)
Speedo communication on first serial line OK
Communication with TCMS OK. Char received.
TCMS frame is valid (CRCs and length)
Valid frame received from LTZH 0n channel 0
Valid frame received from LTZH 0n channel 1
LTZH frame is valid (length, integrity, BCC)
Information about communication with DATR board
Communication OK
Communication OK
Communication OK
Communication OK
Communication OK
Communication OK
Communication OK
Queensland Rail Event Recorder: communication OK
Metro Beijing ATP Communication OK

DualMVB
Speedo comm 2 OK

Speedo communication on second serial line OK

01.12.2011

Teloc 2500 - Error list

900 - 999 General / system events


These events are used to remove internal warnings/info from the error list. No error entry is added to the actual error list.
The recording takes place normally.

Error Code Error Level


900
901
905
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
940
941
942
943
950
951
960
961
962
963
964
965
966
967
970
971
972
974
975
976
977
-

978
979
980
981
982
983
984
985
986
987
988
999

HaslerRail AG - Confidential
ErrorList.xls

SW Name

Codes to delete

ERRC_SYSTEM_EVENT
ERRC_BUS_ERROR_REPORT
ERRC_DATAFLASH_ERROR
ERRC_DATE_TIME_CHANGED
ERRC_ERRC_VEHICLE_ID_CHANGED
ERRC_FPM_CONNECTION_OK
ERRC_FPM_UNLOCKED
ERRC_FPM_OK

110
120
260
261
262

ERRC_USB_STICK_INFO
ERRC_FREQINPUT_INFO
ERRC_SW_CHANGED
ERRC_STM_UNLOCKED
ERRC_LTM_UNLOCKED
ERRC_EVM_UNLOCKED
ERRC_FLEXM1_UNLOCKED
ERRC_FLEXM2_UNLOCKED
ERRC_FLEXM3_UNLOCKED
ERRC_FLEXM4_UNLOCKED
ERRC_FLEXM5_UNLOCKED
ERRC_FLEXM6_UNLOCKED
ERRC_FLEXM7_UNLOCKED
ERRC_FLEXM8_UNLOCKED
ERRC_WHEELDIAM_CHANGED
ERRC_NEW_WHEELDIAM

263
264
265
267
268
269
270
271
272
273
274
130
-

ERRC_NEW_PPS_SYNCHRO
ERRC_NEW_SAT_INFO
ERRC_NEW_BAT_DATE
ERRC_NEW_DIST_CNTR

ERRC_UNKNOWN_EVENT
ERRC_UNKNOWN_MSG_ID
ERRC_SECURITY_DATA_READ
ERRC_SECURITY_DATA_ERASE
ERRC_SECURITY_CONFIGURATION
ERRC_SECURITY_FIRMWARE
ERRC_SECURITY_PARAMETER
ERRC_SECURITY_OTHER

ERRC_SABO_EVENT
ERRC_SABO_EVENT_CH1
ERRC_SABO_EVENT_CH2
ERRC_LOGYTEL_DISPLAY_ERROR
ERRC_LOGYTEL_DISPLAY_OK

ERRC_VOBC_MSG1_MISSING
ERRC_MVBS_EVENT

ERRC_MVB_SLT_LIFE_SIG_ERROR
ERRC_MVB_SLT_LIFE_SIG_OK
ERRC_DEL_USER_ALARM_II
ERRC_DEL_USER_ALARM_IE
ERRC_DEL_USER_ALARM_WI
ERRC_DEL_USER_ALARM_WE
ERRC_DEL_USER_ALARM_FI
ERRC_DEL_USER_ALARM_FE
ERRC_POS12V_OK
ERRC_NEG12V_OK

773
-

510
610
160
410
30
320
161
162

ERRC_DATR_EVENT
ERRC_MAX_ERROR

Error message (32 char max)


System event
Bus Error gave reboot
DataFlash error:
New date/time entered:
Vehicle Id changed [old/new]:
CPM connected again
CPM unlocked
CPM ok
USB stick info
Frequency input info:
SW appli has changed:
STM has been unlocked
LTM has been unlocked
EVM has been unlocked
FLEXM1 has been unlocked
FLEXM2 has been unlocked
FLEXM3 has been unlocked
FLEXM4 has been unlocked
FLEXM5 has been unlocked
FLEXM6 has been unlocked
FLEXM7 has been unlocked
FLEXM8 has been unlocked
New wheel diam. [nb/old/new]:
New wheel diam. [nb/axleNum]:
New time synchro
Sat found or lost
New battery date [old/new]:
New distance counter [old/new]:
Unknown event, not recorded
Unknown message id
User Read Data:
User Erase Data:
User Change Configuration:
User SW Update:
User Change Parameter:
User Operation:
Sabo event occured
Sabo event channel 1
Sabo event channel 2

Error/Event explanation
A normal event occurs (poweron, powerfail, ...)
A bus error occurred and has given a reboot
A bus error occurred in the dataflash
Valid date/time was entered.
Valid vehicle Id was introduced.
The connection with the CPM is ok
Now association between CPM and TELOC is ok
CPM as no error and is not busy
information about USB stick
A problem occured on the measure of a frequency input
The TELOC SW has been updated
STM has been unlocked. The whole content of the internal STM has been read.
LTM has been unlocked. The whole content of the internal LTM has been read.
EVM has been unlocked. The whole content of the internal EVM has been read.
FLEXM1 has been unlocked. The whole content of the internal FLEXM1 has been read.
FLEXM2 has been unlocked. The whole content of the internal FLEXM2 has been read.
FLEXM3 has been unlocked. The whole content of the internal FLEXM3 has been read.
FLEXM4 has been unlocked. The whole content of the internal FLEXM4 has been read.
FLEXM5 has been unlocked. The whole content of the internal FLEXM5 has been read.
FLEXM6 has been unlocked. The whole content of the internal FLEXM6 has been read.
FLEXM7 has been unlocked. The whole content of the internal FLEXM7 has been read.
FLEXM8 has been unlocked. The whole content of the internal FLEXM8 has been read.
A new wheel diameter was entered.
A new wheel diameter was entered.
From gps
From gps
A new battery date was entered.
A new value for the distance counter has been entered.
An unknown event to record has been encountered.
This message id is unknown. Do nothing.
upon data download - one event log per memory type ! Followed by username
upon data erase - Followed by username
upon configuration (TELOC or SABO) change - followed by username
upon software change - followed by username
upon unit parameter change - followed by username
upon other service operations - followed by username and a code

VOBC msg1 missing


"BSG" "ZSG" for AVE_S103
"CCU" "CCUmaster" "KLIP" for
Boston

VOBC message1 not received (first message)


Give the MVB devives(s) with port(s) that are not ok.

MVB SLT life sig error


MVB SLT life sig ok
Del the user alarm level
Del the user alarm level
Del the user alarm level
Del the user alarm level
Del the user alarm level
Del the user alarm level
Positive 12V is OK
Negative 12V is OK
DATR board event:
-

PortNum_SignalName, count_difference as parameters


PortNum_SignalName, count_difference as parameters
Delete the user defined alarm level 2
Delete the user defined alarm level 3
Delete the user defined alarm level 4
Delete the user defined alarm level 5
Delete the user defined alarm level 8
Delete the user defined alarm level 9
The +12V is OK
The -12V is OK
The DATR board has notify an event
Reserved. Don't use.

2
3
4
5
8
9

01.12.2011

Вам также может понравиться